1
|
McKechnie V, Khan S, Saunders R, Amiel SA, Gonder-Frederick LA, Oliver N. Psychometric validation of the hyperglycaemia avoidance scale UK (HAS-UK). Diabet Med 2024; 41:e15342. [PMID: 38687846 DOI: 10.1111/dme.15342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 04/11/2024] [Accepted: 04/18/2024] [Indexed: 05/02/2024]
Abstract
AIMS Hyperglycaemia aversion in type 1 diabetes can be associated with severe hypoglycaemia and impaired awareness of hypoglycaemia but is not routinely assessed clinically. This study aimed to undertake the first psychometric validation of the UK version of the Hyperglycaemia Avoidance Scale (HAS-UK). METHODS The HAS-UK was completed by adults with type 1 diabetes in three separate research studies. Psychometric properties were evaluated, using exploratory factor analysis, internal consistency, and convergent validity. RESULTS Of the 431 participants who completed the HAS-UK in the three studies, mean age was 49.5 years, and 58.0% were women. Mean duration of diabetes was 29 years, with 192 (44.5%) using multiple daily injections and 229 (53.1%) using an insulin pump. Five participants were excluded from analyses due to incomplete HAS-UK responses. Exploratory factor analysis revealed a 3-factor solution, with acceptable internal consistency for 'worry' and 'blood glucose decisions' factors. HAS-UK total score was higher in those using insulin pumps versus multiple daily injections, and 'blood glucose decisions' score was higher in those using a continuous blood glucose sensor versus a meter. CONCLUSIONS The HAS-UK is a reliable measure with acceptable structural validity and is likely to be useful for evaluating hyperglycaemia aversion in people with type 1 diabetes. Future research would benefit from investigating further psychometric properties including test-retest reliability, sensitivity to change, and clinical significance of scores.
Collapse
Affiliation(s)
- Vicky McKechnie
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Department of Clinical Health Psychology and Neuropsychology, Imperial College Healthcare NHS Trust and West London NHS Trust, London, UK
| | - Shaila Khan
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Rob Saunders
- CORE Data Lab, Centre for Outcomes Research and Effectiveness (CORE), Research Department of Clinical, Educational, and Health Psychology, University College London, London, UK
| | - Stephanie A Amiel
- Department of Diabetes, Faculty of Life Sciences, King's College London, London, UK
| | - Linda A Gonder-Frederick
- Center for Diabetes Technology, School of Medicine, University of Virginia, Charlottesville, Virginia, USA
| | - Nick Oliver
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| |
Collapse
|
2
|
Lin YK, Hepworth E, de Zoysa N, McCurley J, Vajravelu ME, Ye W, Piatt GA, Amiel SA, Fisher SJ, Pop-Busui R, Aikens JE. Relationships of hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring glycemic profiles with anxiety and depression symptoms in adults with type 1 diabetes using continuous glucose monitoring systems. Diabetes Res Clin Pract 2024; 209:111596. [PMID: 38428746 PMCID: PMC10960959 DOI: 10.1016/j.diabres.2024.111596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 02/22/2024] [Indexed: 03/03/2024]
Abstract
AIMS To evaluate relationships of hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring (CGM) glycemic profiles with anxiety and depression symptoms in adults with type 1 diabetes (T1D) who use CGM. METHODS A cross-sectional survey and data collections were completed with 196 T1D adults who used CGM (59% also used automated insulin delivery devices (AIDs)). We assessed hypoglycemia awareness (Gold instrument), hypoglycemia beliefs (Attitudes to Awareness of Hypoglycemia instrument), CGM glycemic profiles, demographics, and anxiety and depression symptoms (Hospital Anxiety and Depression Scale). Analysis included simple and multiple linear regression analyses. RESULTS Lower hypoglycemia awareness, weaker "hypoglycemia concerns minimized" beliefs, stronger "hyperglycemia avoidance prioritized" beliefs were independently associated with higher anxiety symptoms (P < 0.05), with similar trends in both subgroups using and not using AIDs. Lower hypoglycemia awareness were independently associated with greater depression symptoms (P < 0.05). In participants not using AIDs, more time in hypoglycemia was related to less anxiety and depression symptoms (P < 0.05). Being female and younger were independently associated with higher anxiety symptoms, while being younger was also independently associated with greater depression symptoms (P < 0.05). CONCLUSION Our findings revealed relationships of impaired hypoglycemia awareness, hypoglycemia beliefs, CGM-detected hypoglycemia with anxiety and depression symptoms in T1D adults who use CGMs.
Collapse
Affiliation(s)
- Yu Kuei Lin
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA.
| | - Emily Hepworth
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - Nicole de Zoysa
- Department of Diabetes, King's College Hospital NHS Foundation Trust, London SE5 9RS, UK
| | - Jessica McCurley
- Department of Psychology, San Diego State University, San Diego, CA 92182, USA
| | - Mary Ellen Vajravelu
- Center for Pediatric Research in Obesity and Metabolism, University of Pittsburgh School of Medicine, Pittsburgh, PA 15224, USA
| | - Wen Ye
- Department of Biostatistics, University of Michigan School of Public Health, Ann Arbor, MI 48105, USA
| | - Gretchen A Piatt
- Department of Learning Health Sciences, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - Stephanie A Amiel
- Department of Diabetes, School of Cardiovascular and Metabolic Medicine and Sciences, Kings College London, London SE5 9RJ, UK
| | - Simon J Fisher
- Department of Internal Medicine, University of Kentucky College of Medicine, Lexington, KY 40508, USA
| | - Rodica Pop-Busui
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - James E Aikens
- Department of Family Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| |
Collapse
|
3
|
McKechnie V, Oliver N, Amiel SA, Fox JRE. Hyperglycaemia aversion in type 1 diabetes: A grounded theory study. Br J Health Psychol 2024; 29:254-271. [PMID: 37806779 DOI: 10.1111/bjhp.12697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 05/12/2023] [Accepted: 09/26/2023] [Indexed: 10/10/2023]
Abstract
OBJECTIVE Very little is known about the circumstances under which hyperglycaemia aversion develops and is maintained. The present study aimed to identify psychological factors involved in the process of hyperglycaemia aversion and to understand how it affects people's self-management of type 1 diabetes. DESIGN Qualitative, in-depth interviews were used. METHODS A constructivist grounded theory study, using semi-structured participant interviews, was undertaken to build a theoretical model of the process of hyperglycaemia aversion. RESULTS Eighteen participants were interviewed. Fifteen were considered hyperglycaemia averse and included in the analysis. A theoretical model was developed to describe and explain processes involved in hyperglycaemia aversion. Many participants held very high standards for themselves and often had a strong preference for control. While some participants described anxiety associated with higher blood glucose, the most proximal driver of their approach was self-criticism and frustration associated with not meeting their own high standards for blood glucose. A number of attentional processes and beliefs, mostly related to hypoglycaemia, maintained and reinforced their blood glucose preference. Diabetes technology served as an enabler, raiser of standards, and additional critical judge of participants' hyperglycaemia aversion. CONCLUSIONS The trans-diagnostic concept of emotional over-control is used to understand the proposed model of processes of hyperglycaemia aversion. The present study offers new insight which will aid clinicians in identifying and supporting those who may be at risk of psychological distress and harm associated with a preference for avoidance of higher blood glucose levels.
Collapse
Affiliation(s)
- Vicky McKechnie
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
- Department of Clinical Health Psychology and Neuropsychology, Imperial College Healthcare NHS Trust and West London NHS Trust, London, UK
| | - Nick Oliver
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK
| | - Stephanie A Amiel
- Department of Diabetes, Faculty of Life Sciences, King's College London, London, UK
- King's College Hospital NHS Foundation Trust, London, UK
| | - John R E Fox
- School of Psychology, Cardiff University, Cardiff, UK
| |
Collapse
|
4
|
ElSayed NA, Aleppo G, Bannuru RR, Bruemmer D, Collins BS, Ekhlaspour L, Hilliard ME, Johnson EL, Khunti K, Lingvay I, Matfin G, McCoy RG, Perry ML, Pilla SJ, Polsky S, Prahalad P, Pratley RE, Segal AR, Seley JJ, Selvin E, Stanton RC, Gabbay RA. 6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes-2024. Diabetes Care 2024; 47:S111-S125. [PMID: 38078586 PMCID: PMC10725808 DOI: 10.2337/dc24-s006] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, an interprofessional expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
5
|
Kuei Lin Y, Hepworth E, de Zoysa N, McCurley J, Ellen Vajravelu M, Ye W, Piatt GA, Amiel SA, Fisher SJ, Pop-Busui R, Aikens JE. Associations Between Hypoglycemia Awareness, Hypoglycemia Beliefs, and Continuous Glucose Monitoring Glycemic Profiles and Anxiety and Depression Symptoms in Adults with Type 1 Diabetes Using Advanced Diabetes Technologies. Diabetes Res Clin Pract 2023:111059. [PMID: 38104898 DOI: 10.1016/j.diabres.2023.111059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 12/13/2023] [Indexed: 12/19/2023]
Abstract
AIMS To evaluate relationships between hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring (CGM) glycemic profiles and anxiety and depression symptoms in adults with type 1 diabetes (T1D) who use CGM or automated insulin delivery devices. METHODS A cross-sectional survey and data collections were completed with 196 T1D adults who used advanced diabetes technologies. We assessed hypoglycemia awareness (Gold instrument), hypoglycemia beliefs (Attitudes to Awareness of Hypoglycemia instrument), CGM glycemic profiles, demographics, and anxiety and depression symptoms (Hospital Anxiety and Depression Scale). Data were processed via regression analyses and receiver operating characteristic analyses. RESULTS Lower hypoglycemia awareness, weaker "hypoglycemia concerns minimized" beliefs, stronger "hyperglycemia avoidance prioritized" beliefs, female, and younger age were independently associated with higher anxiety symptoms (P<0.05). Lower hypoglycemia awareness, less time in hypoglycemia, and younger age were independently associated with greater depression symptoms (P<0.05). Age of <50 years had 77.8% sensitivity and 48.8% specificity in detecting elevated anxiety symptoms. Spending ≥35% of time with glucose levels >180 mg/dL on CGMs had 85.7% sensitivity and 54.3% specificity in detecting elevated depression symptoms. CONCLUSION Our findings revealed relationships between impaired hypoglycemia awareness, hypoglycemia beliefs, CGM-detected hypoglycemia and anxiety and depression symptoms in T1D adults who use advanced diabetes technologies.
Collapse
Affiliation(s)
- Yu Kuei Lin
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA.
| | - Emily Hepworth
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - Nicole de Zoysa
- Department of Diabetes, King's College Hospital NHS Foundation Trust, London SE5 9RS, UK
| | - Jessica McCurley
- Department of Psychology, San Diego State University, San Diego, CA 92182, USA
| | - Mary Ellen Vajravelu
- Center for Pediatric Research in Obesity and Metabolism, University of Pittsburgh School of Medicine, Pittsburgh, PA 15224, USA
| | - Wen Ye
- Department of Biostatistics, University of Michigan School of Public Health, Ann Arbor, MI 48105, USA
| | - Gretchen A Piatt
- Department of Learning Health Sciences, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - Stephanie A Amiel
- Department of Diabetes, School of Cardiovascular and Metabolic Medicine and Sciences, Kings College London, London SE5 9RJ, UK
| | - Simon J Fisher
- Department of Internal Medicine, University of Kentucky College of Medicine, Lexington, KY 40508, USA
| | - Rodica Pop-Busui
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| | - James E Aikens
- Department of Family Medicine, University of Michigan Medical School, Ann Arbor, MI 48105, USA
| |
Collapse
|
6
|
Mangas N, Mateu-Salat M, Martínez MJ, López A, Pujol I, Martínez C, Corcoy R. Hybrid closed-loop systems can help patients with extreme fear of hypoglycemia or hyperglycemia. Hormones (Athens) 2023; 22:453-456. [PMID: 37198528 DOI: 10.1007/s42000-023-00451-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 04/26/2023] [Indexed: 05/19/2023]
Abstract
Fear of hypoglycemia and hyperglycemia can lead to inappropriate diabetes self-management and untoward health outcomes. We report two patients, representative of these opposite conditions, who benefited from hybrid closed-loop technology. In the patient with fear of hypoglycemia, time in range improved from 26 to 56% and the patient did not present with severe hypoglycemia. Meanwhile, the patient with hyperglycemia aversiveness had a drastic reduction in time below range, from 19 to 4%. We conclude that hybrid closed-loop technology was an effective tool for improvement of glucose values in two patients with fear of hypoglycemia and hyperglycemia aversiveness, respectively.
Collapse
Affiliation(s)
- Natalia Mangas
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - Manel Mateu-Salat
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - María José Martínez
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - Alicia López
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - Isabel Pujol
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - Carmen Martínez
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain
| | - Rosa Corcoy
- Department of Endocrinology and Nutrition, Hospital de la Santa Creu I Sant Pau, C/Sant Quintí 89, 08042, Barcelona, Spain.
- CIBER-BBN, Instituto de Salud Carlos III, Madrid, Spain.
- Department of Medicine, Universitat Autònoma de Barcelona, Barcelona, Spain.
- Sant Pau Biomedical Research Institute (IIB Sant Pau), Barcelona, Spain.
| |
Collapse
|
7
|
Lin YK, Agni A, Chuisano S, de Zoysa N, Fetters M, Amiel SA, Pop-Busui R, DeJonckheere M. 'You have to use everything and come to some equilibrium': a qualitative study on hypoglycemia self-management in users of continuous glucose monitor with diverse hypoglycemia experiences. BMJ Open Diabetes Res Care 2023; 11:e003415. [PMID: 37349107 PMCID: PMC10314535 DOI: 10.1136/bmjdrc-2023-003415] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 06/08/2023] [Indexed: 06/24/2023] Open
Abstract
INTRODUCTION Although continuous glucose monitoring systems (CGMs) can help reduce hypoglycemia, about one-quarter of people with type 1 diabetes (T1D) who use CGMs still either spend at least 1% of the time with dangerously low blood glucose or develop severe hypoglycemia. This study explored experiences around hypoglycemia self-management in people who are living with T1D and using CGMs to identify factors contributing to hypoglycemia development. RESEARCH DESIGN AND METHODS Purposive sampling and semistructured interviews with 28 respondents with T1D and using CGMs were conducted to explore experiences around hypoglycemic episodes and hypoglycemia self-management during CGM use. Open coding and thematic analysis were employed to identify emergent themes related to hypoglycemia experiences. RESULTS About one-third of respondents each respectively spent 0%, 0.1%-0.9% and ≥1% of time in level 2 hypoglycemia; 39% had impaired awareness of hypoglycemia and 32% had severe hypoglycemia in the past 6 months. Four themes were generated: (1) prioritizing symptoms over CGM data (subthemes: hypoglycemia symptoms for confirming hypoglycemia and prompting management actions; minimal management actions without hypoglycemia symptoms); (2) distraction from the demands of daily life; (3) concerns about hypoglycemia management choices (subthemes: fear of rebound hyperglycemia; other health consequences related to sugary food consumption; aversions to treatment foods and treatment food consumption); and (4) social influences on management choices (subthemes: positively perceived social support and inclusion; unwanted attention to oneself or concerns about inconveniencing others; social stigma and criticism related to hypoglycemia and CGM use). CONCLUSIONS Despite using CGMs, people with T1D can face a complex biopsychosocial process of managing hypoglycemia. Interventions for addressing psychosocial and behavioral barriers are needed to improve hypoglycemia self-management in those who continue to face challenges in minimizing hypoglycemia while using CGMs.
Collapse
Affiliation(s)
- Yu Kuei Lin
- Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Annika Agni
- Department of Family Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Samantha Chuisano
- Department of Family Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Nicole de Zoysa
- Department of Diabetes, King's College Hospital NHS Foundation Trust, London, UK
| | - Michael Fetters
- Department of Family Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | | | - Rodica Pop-Busui
- Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | | |
Collapse
|
8
|
Sepúlveda E, Jacob P, Poínhos R, Carvalho D, Vicente SG, Smith EL, Shaw JAM, Speight J, Choudhary P, de Zoysa N, Amiel SA. Changes in attitudes to awareness of hypoglycaemia during a hypoglycaemia awareness restoration programme are associated with avoidance of further severe hypoglycaemia episodes within 24 months: the A2A in HypoCOMPaSS study. Diabetologia 2023; 66:631-641. [PMID: 36538062 PMCID: PMC9947080 DOI: 10.1007/s00125-022-05847-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 10/06/2022] [Indexed: 12/25/2022]
Abstract
AIMS/HYPOTHESIS The aims of this study were to assess cognitions relating to hypoglycaemia in adults with type 1 diabetes and impaired awareness of hypoglycaemia before and after the multimodal HypoCOMPaSS intervention, and to determine cognitive predictors of incomplete response (one or more severe hypoglycaemic episodes over 24 months). METHODS This analysis included 91 adults with type 1 diabetes and impaired awareness of hypoglycaemia who completed the Attitudes to Awareness of Hypoglycaemia (A2A) questionnaire before, 24 weeks and 24 months after the intervention, which comprised a short psycho-educational programme with optimisation of insulin therapy and glucose monitoring. RESULTS The age and diabetes duration of the participants were 48±12 and 29±12 years, respectively (mean±SD). At baseline, 91% reported one or more severe hypoglycaemic episodes over the preceding 12 months; this decreased to <20% at 24 weeks and after 24 months (p=0.001). The attitudinal barrier 'hyperglycaemia avoidance prioritised' (η2p=0.250, p=0.001) decreased from baseline to 24 weeks, and this decrease was maintained at 24 months (mean±SD=5.3±0.3 vs 4.3±0.3 vs 4.0±0.3). The decrease in 'asymptomatic hypoglycaemia normalised' from baseline (η2p=0.113, p=0.045) was significant at 24 weeks (1.5±0.3 vs 0.8±0.2). Predictors of incomplete hypoglycaemia response (one or more further episodes of severe hypoglycaemia) were higher baseline rates of severe hypoglycaemia, higher baseline scores for 'asymptomatic hypoglycaemia normalised', reduced change in 'asymptomatic hypoglycaemia normalised' scores at 24 weeks, and lower baseline 'hypoglycaemia concern minimised' scores (all p<0.05). CONCLUSIONS/INTERPRETATION Participation in the HypoCOMPaSS RCT was associated with improvements in hypoglycaemia-associated cognitions, with 'hyperglycaemia avoidance prioritised' most prevalent. Incomplete prevention of subsequent severe hypoglycaemia episodes was associated with persistence of the cognition 'asymptomatic hypoglycaemia normalised'. Understanding and addressing cognitive barriers to hypoglycaemia avoidance is important in individuals prone to severe hypoglycaemia episodes. CLINICAL TRIALS REGISTRATION www.isrctn.org : ISRCTN52164803 and https://eudract.ema.europa.eu : EudraCT2009-015396-27.
Collapse
Affiliation(s)
- Eduardo Sepúlveda
- Diabetes Research Group, King's College London, London, UK
- Centre for Psychology at Universidade do Porto, Faculty of Psychology and Educational Sciences, Universidade do Porto, Porto, Portugal
| | - Peter Jacob
- Diabetes Research Group, King's College London, London, UK
- King's College Hospital NHS Foundation Trust, London, UK
| | - Rui Poínhos
- Faculty of Nutrition and Food Sciences, Universidade do Porto, Porto, Portugal
| | - Davide Carvalho
- Department of Endocrinology, Diabetes and Metabolism, Centro Hospitalar São João, Porto, Portugal
- Faculty of Medicine, Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, Portugal
| | - Selene G Vicente
- Centre for Psychology at Universidade do Porto, Faculty of Psychology and Educational Sciences, Universidade do Porto, Porto, Portugal
| | - Emma L Smith
- Diabetes Research Group, King's College London, London, UK
- King's College Hospital NHS Foundation Trust, London, UK
| | - James A M Shaw
- Translational and Clinical Research Institute, Newcastle University, Newcastle upon Tyne, UK.
| | - Jane Speight
- School of Psychology, Deakin University, Geelong, VIC, Australia
- The Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Melbourne, VIC, Australia
| | - Pratik Choudhary
- Diabetes Research Group, King's College London, London, UK
- King's College Hospital NHS Foundation Trust, London, UK
- Leicester Diabetes Centre, University of Leicester, Leicester, UK
| | - Nicole de Zoysa
- Diabetes Research Group, King's College London, London, UK
- King's College Hospital NHS Foundation Trust, London, UK
| | - Stephanie A Amiel
- Diabetes Research Group, King's College London, London, UK.
- King's College Hospital NHS Foundation Trust, London, UK.
| | | |
Collapse
|
9
|
ElSayed NA, Aleppo G, Aroda VR, Bannuru RR, Brown FM, Bruemmer D, Collins BS, Hilliard ME, Isaacs D, Johnson EL, Kahan S, Khunti K, Leon J, Lyons SK, Perry ML, Prahalad P, Pratley RE, Seley JJ, Stanton RC, Gabbay RA. 6. Glycemic Targets: Standards of Care in Diabetes-2023. Diabetes Care 2023; 46:S97-S110. [PMID: 36507646 PMCID: PMC9810469 DOI: 10.2337/dc23-s006] [Citation(s) in RCA: 277] [Impact Index Per Article: 277.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
10
|
Abstract
The American Diabetes Association (ADA) "Standards of Medical Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee (https://doi.org/10.2337/dc22-SPPC), are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations, please refer to the Standards of Care Introduction (https://doi.org/10.2337/dc22-SINT). Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|