1
|
Sabahat S, Nazish Y, Saira F, Tariq I, Khan ZUH, Saleem RSZ, Abdullah MMS, Chen YM. Fabrication of Supported and Unsupported Gold Nanorods for Nonenzymatic Glucose Sensing and Study of Their Growth Kinetics. ACS OMEGA 2024; 9:33616-33628. [PMID: 39130546 PMCID: PMC11307306 DOI: 10.1021/acsomega.4c01313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 07/01/2024] [Accepted: 07/12/2024] [Indexed: 08/13/2024]
Abstract
This work includes a novel approach for synthesis/fabrication of AuNRs of varied aspect ratios leading to investigation on the kinetics of their growth mechanism. The synthesized AuNRs were further functionalized with MWCNTs (AuNRs@MWCNTs) by one-pot synthesis. The synthesized AuNRs and AuNRs@MWCNTs were characterized by employing UV-vis spectroscopy. Red shifts in the spectra of AuNRs confirmed the formation of nanorods of higher aspect ratios. Morphology of AuNRs and functionalized AuNRs was confirmed by high-resolution scanning electron microscopy. Biological studies were carried out by fabricating efficient nonenzymatic glucose sensors for optical and electrochemical sensing via UV and cyclic voltammetry in the detection ranges of 0.7-28 mM glucose (UV) and 5.5 μM-0.33 mM (CV). An electrochemical sensing study was carried out via AuNR- and AuNRs@MWCNT-modified GCEs in a 0.1 M NaOH electrolyte solution. The modified electrodes exhibited very high sensitivity with a broad linear range. The order of sensitivity (via CV) was found to be AuNRX0@MWCNTs > AuNRD5@MWCNTs > AuNRD5 > AuNRX0.
Collapse
Affiliation(s)
- Sana Sabahat
- Department
of Chemistry, COMSATS University Islamabad, Islamabad 44000, Pakistan
| | - Yumna Nazish
- Department
of Chemistry, COMSATS University Islamabad, Islamabad 44000, Pakistan
| | - Farhat Saira
- Nanoscience
and Technology Division, National Centre
for Physics (NCP), QAU Campus, Shahdra Valley Road, Islamabad 44000, Pakistan
| | - Iqra Tariq
- Department
of Chemistry, COMSATS University Islamabad, Islamabad 44000, Pakistan
| | - Zia Ul Haq Khan
- Department
of Chemistry, COMSATS University Islamabad, Islamabad 44000, Pakistan
| | - Rahman Shah Zaib Saleem
- Department
of Chemistry and Chemical Engineering, SBASSE, Lahore University of Management Sciences (LUMS), DHA, Lahore 54792, Pakistan
| | - Mahmood M. S. Abdullah
- Department
of Chemistry, College of Science, King Saud
University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Yong-Mei Chen
- College
of Chemistry, Beijing University of Chemical
Technology, Beijing 100029, China
| |
Collapse
|
2
|
Ramya PR, Halder S, Nagamani K, Singh Chouhan R, Gandhi S. Disposable graphene-oxide screen-printed electrode integrated with portable device for detection of SARS-CoV-2 in clinical samples. Bioelectrochemistry 2024; 158:108722. [PMID: 38697015 DOI: 10.1016/j.bioelechem.2024.108722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/19/2024] [Accepted: 04/27/2024] [Indexed: 05/04/2024]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis is the need of the hour, as cases are persistently increasing, and new variants are constantly emerging. The ever-changing nature of the virus leading to multiple variants, has brought an imminent need for early, accurate and rapid detection methods. Herein, we have reported the design and fabrication of Screen-Printed Electrodes (SPEs) with graphene oxide (GO) as working electrode and modified with specific antibodies for SARS-CoV-2 Receptor Binding Domain (RBD). Flexibility of design, and portable nature has made SPEs the superior choice for electrochemical analysis. The developed immunosensor can detect RBD as low as 0.83 fM with long-term storage capacity. The fabricated SPEs immunosensor was tested using a miniaturized portable device and potentiostat on 100 patient nasopharyngeal samples and corroborated with RT-PCR data, displayed 94 % sensitivity. Additionally, the in-house developed polyclonal antibodies detected RBD antigen of the mutated Omicron variant of SARS-CoV-2 successfully. We have not observed any cross-reactivity/binding of the fabricated immunosensor with MERS (cross-reactive antigen) and Influenza A H1N1 (antigen sharing common symptoms). Hence, the developed SPEs sensor may be applied for bedside point-of-care diagnosis of SARS-CoV-2 using miniaturized portable device, in clinical samples.
Collapse
Affiliation(s)
- P R Ramya
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India; DBT-Regional Centre for Biotechnology (RCB), Faridabad 121001, Haryana, India
| | - Sayanti Halder
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | - K Nagamani
- Department of Microbiology, Gandhi Medical College, Gandhi Hospital, Hyderabad 500025, Telangana, India
| | - Raghuraj Singh Chouhan
- Department of Environmental Sciences, Jožef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana, Slovenia
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India; DBT-Regional Centre for Biotechnology (RCB), Faridabad 121001, Haryana, India.
| |
Collapse
|
3
|
Hosnedlova B, Werle J, Cepova J, Narayanan VHB, Vyslouzilova L, Fernandez C, Parikesit AA, Kepinska M, Klapkova E, Kotaska K, Stepankova O, Bjorklund G, Prusa R, Kizek R. Electrochemical Sensors and Biosensors for Identification of Viruses: A Critical Review. Crit Rev Anal Chem 2024:1-30. [PMID: 38753964 DOI: 10.1080/10408347.2024.2343853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Due to their life cycle, viruses can disrupt the metabolism of their hosts, causing diseases. If we want to disrupt their life cycle, it is necessary to identify their presence. For this purpose, it is possible to use several molecular-biological and bioanalytical methods. The reference selection was performed based on electronic databases (2020-2023). This review focused on electrochemical methods with high sensitivity and selectivity (53% voltammetry/amperometry, 33% impedance, and 12% other methods) which showed their great potential for detecting various viruses. Moreover, the aforementioned electrochemical methods have considerable potential to be applicable for care-point use as they are portable due to their miniaturizability and fast speed analysis (minutes to hours), and are relatively easy to interpret. A total of 2011 articles were found, of which 86 original papers were subsequently evaluated (the majority of which are focused on human pathogens, whereas articles dealing with plant pathogens are in the minority). Thirty-two species of viruses were included in the evaluation. It was found that most of the examined research studies (77%) used nanotechnological modifications. Other ones performed immunological (52%) or genetic analyses (43%) for virus detection. 5% of the reports used peptides to increase the method's sensitivity. When evaluable, 65% of the research studies had LOD values in the order of ng or nM. The vast majority (79%) of the studies represent proof of concept and possibilities with low application potential and a high need of further research experimental work.
Collapse
Affiliation(s)
- Bozena Hosnedlova
- BIOCEV, First Faculty of Medicine, Charles University, Vestec, Czech Republic
| | - Julia Werle
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| | - Jana Cepova
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| | - Vedha Hari B Narayanan
- Pharmaceutical Technology Lab, School of Chemical & Biotechnology, SASTRA Deemed University, Thanjavur, India
| | - Lenka Vyslouzilova
- Czech Institute of Informatics, Robotics and Cybernetics, Department of Biomedical Engineering & Assistive Technologies, Czech Technical University in Prague, Prague, Czech Republic
| | - Carlos Fernandez
- School of Pharmacy and Life Sciences, Robert Gordon University, Aberdeen, United Kingdom
| | - Arli Aditya Parikesit
- Department of Bioinformatics, School of Life Sciences, Indonesia International Institute for Life Sciences, Jakarta, Timur, Indonesia
| | - Marta Kepinska
- Department of Pharmaceutical Biochemistry, Faculty of Pharmacy, Wroclaw Medical University, Wroclaw, Poland
| | - Eva Klapkova
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| | - Karel Kotaska
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| | - Olga Stepankova
- Czech Institute of Informatics, Robotics and Cybernetics, Department of Biomedical Engineering & Assistive Technologies, Czech Technical University in Prague, Prague, Czech Republic
| | - Geir Bjorklund
- Council for Nutritional and Environmental Medicine (CONEM), Mo i Rana, Norway
| | - Richard Prusa
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| | - Rene Kizek
- Department of Medical Chemistry and Clinical Biochemistry, 2nd Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic
| |
Collapse
|
4
|
Kolhe P, Shah M, Nathani A, Shekhar Sharma C, Gandhi S. Block copolymer-derived recessed nanodisk-array electrodes for electrochemical detection of β-lactam antibiotics. Food Chem 2024; 435:137557. [PMID: 37774611 DOI: 10.1016/j.foodchem.2023.137557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 09/11/2023] [Accepted: 09/19/2023] [Indexed: 10/01/2023]
Abstract
Antimicrobial resistance (AMR) is one of the major socio-economic factors contributing to public health. β-lactams are most commonly prescribed drugs for variety of bacterial infections. Frequent use of antibiotics leads to AMR in humans and animals. The present work is focused on developing an electro-immunosensor to control and regulate the excessive use of antibiotics in animal-based food products. An amphiphilic block co-polymer poly(ethylene oxide-block-methyl methacrylate)(PEO-b-PMMA) was used to fabricate recessed nano-disk array electrode (RNE) and immobilized with Pen-Ab and Cef-Ab antibodies. The Limit of detection (LOD) of RNE working electrode was found to be 14.8 pM for penicillin and 13.8 pM for cefalexin with good selectivity in presence of non-specific antibiotics. Fabricated RNE electrode could detect trace amounts of spiked antigen in real samples of milk, egg and meat extract. Further, mesoporous thin film and microarrays can eventually be used to develop point-of-care diagnosis of antibiotics in animal-based food products.
Collapse
Affiliation(s)
- Pratik Kolhe
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | - Maitri Shah
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | - Akash Nathani
- Creative & Advanced Research Based On Nanomaterials (CARBON) Lab, Department of Chemical Engineering, Indian Institute of Technology, Kandi, Sangareddy 502285, Telangana, India
| | - Chandra Shekhar Sharma
- Creative & Advanced Research Based On Nanomaterials (CARBON) Lab, Department of Chemical Engineering, Indian Institute of Technology, Kandi, Sangareddy 502285, Telangana, India
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India.
| |
Collapse
|
5
|
Ramalingam M, Jaisankar A, Cheng L, Krishnan S, Lan L, Hassan A, Sasmazel HT, Kaji H, Deigner HP, Pedraz JL, Kim HW, Shi Z, Marrazza G. Impact of nanotechnology on conventional and artificial intelligence-based biosensing strategies for the detection of viruses. DISCOVER NANO 2023; 18:58. [PMID: 37032711 PMCID: PMC10066940 DOI: 10.1186/s11671-023-03842-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 03/28/2023] [Indexed: 04/05/2023]
Abstract
Recent years have witnessed the emergence of several viruses and other pathogens. Some of these infectious diseases have spread globally, resulting in pandemics. Although biosensors of various types have been utilized for virus detection, their limited sensitivity remains an issue. Therefore, the development of better diagnostic tools that facilitate the more efficient detection of viruses and other pathogens has become important. Nanotechnology has been recognized as a powerful tool for the detection of viruses, and it is expected to change the landscape of virus detection and analysis. Recently, nanomaterials have gained enormous attention for their value in improving biosensor performance owing to their high surface-to-volume ratio and quantum size effects. This article reviews the impact of nanotechnology on the design, development, and performance of sensors for the detection of viruses. Special attention has been paid to nanoscale materials, various types of nanobiosensors, the internet of medical things, and artificial intelligence-based viral diagnostic techniques.
Collapse
Affiliation(s)
- Murugan Ramalingam
- School of Basic Medical Sciences, Clinical Medical College & Affiliated Hospital, Chengdu University, Chengdu, 610106 China
- Institute of Tissue Regeneration Engineering, Dankook University, Cheonan, 31116 Republic of Korea
- Department of Nanobiomedical Science, Dankook University, Cheonan, 31116 Republic of Korea
- BK21 NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, 31116 Republic of Korea
- Mechanobiology Dental Medicine Research Center, Dankook University, Cheonan, 31116 Republic of Korea
- UCL Eastman-Korea Dental Medicine Innovation Centre, Dankook University, Cheonan, 31116 South Korea
- Department of Metallurgical and Materials Engineering, Faculty of Engineering, Atilim University, 06836 Ankara, Turkey
| | - Abinaya Jaisankar
- Centre for Biomaterials, Cellular and Molecular Theranostics, School of Mechanical Engineering, Vellore Institute of Technology, Vellore, 632014 India
| | - Lijia Cheng
- School of Basic Medical Sciences, Clinical Medical College & Affiliated Hospital, Chengdu University, Chengdu, 610106 China
| | - Sasirekha Krishnan
- Centre for Biomaterials, Cellular and Molecular Theranostics, School of Mechanical Engineering, Vellore Institute of Technology, Vellore, 632014 India
| | - Liang Lan
- School of Basic Medical Sciences, Clinical Medical College & Affiliated Hospital, Chengdu University, Chengdu, 610106 China
| | - Anwarul Hassan
- Department of Mechanical and Industrial Engineering, Biomedical Research Center, Qatar University, 2713, Doha, Qatar
| | - Hilal Turkoglu Sasmazel
- Department of Metallurgical and Materials Engineering, Faculty of Engineering, Atilim University, 06836 Ankara, Turkey
| | - Hirokazu Kaji
- Department of Biomechanics, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, 101-0062 Japan
| | - Hans-Peter Deigner
- Institute of Precision Medicine, Medical and Life Sciences Faculty, Furtwangen University, 78054 Villingen-Schwenningen, Germany
| | - Jose Luis Pedraz
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country, 01006 Vitoria-Gasteiz, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine, 28029 Madrid, Spain
| | - Hae-Won Kim
- Institute of Tissue Regeneration Engineering, Dankook University, Cheonan, 31116 Republic of Korea
- Department of Nanobiomedical Science, Dankook University, Cheonan, 31116 Republic of Korea
- BK21 NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, 31116 Republic of Korea
- Mechanobiology Dental Medicine Research Center, Dankook University, Cheonan, 31116 Republic of Korea
- UCL Eastman-Korea Dental Medicine Innovation Centre, Dankook University, Cheonan, 31116 South Korea
| | - Zheng Shi
- School of Basic Medical Sciences, Clinical Medical College & Affiliated Hospital, Chengdu University, Chengdu, 610106 China
| | - Giovanna Marrazza
- Department of Chemistry “Ugo Schiff”, University of Florence, 50019 Sesto Fiorentino, Florence, Italy
| |
Collapse
|
6
|
Roberts A, Dhanze H, Sharma GT, Gandhi S. Point-of-care detection of Japanese encephalitis virus biomarker in clinical samples using a portable smartphone-enabled electrochemical "Sensit" device. Bioeng Transl Med 2023; 8:e10506. [PMID: 37206199 PMCID: PMC10189466 DOI: 10.1002/btm2.10506] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/02/2023] [Accepted: 03/04/2023] [Indexed: 05/21/2023] Open
Abstract
Japanese encephalitis (JE), a neglected tropical zoonotic disease prevalent in south-east Asian and western pacific countries, caused by the flavivirus JE virus (JEV), has a dearth of electrochemical point-of-care (PoC) diagnostic tools available to manage endemic breakouts. To overcome this, we have developed a screen-printed carbon electrode (SPCE) immunosensor for rapid PoC detection of JEV nonstructural 1 (NS1) antigen (Ag), found circulating in serum of infected individuals using a smartphone based portable "Sensit" device. The modification of SPCE surface with JEV NS1 antibody (Ab) was confirmed via observation of globular protein structures via scanning electron microscopy (SEM), increase in electrode surface hydrophilicity via contact angle measurement and decrease in current via differential pulse voltammetry (DPV). The fabrication and testing parameters were optimized based on highest current output obtained using DPV. The SPCE was tested for detection limit of target JEV NS1 Ag ranging from 1 fM to 1 μM, which was determined as 0.45 fM in spiked serum. The disposable immunosensor was also found to be highly specific in detecting JEV NS1 Ag over other flaviviral NS1 Ag. Finally, the modified SPCE was clinically validated by testing 62 clinical JEV samples using both a portable miniaturized electrochemical "Sensit" device coupled with a smartphone and a laboratory-based potentiostat. The results were corroborated with gold-standard RT-PCR and showed 96.77% accuracy, 96.15% sensitivity, and 97.22% specificity. Hence, this technique may further be developed into a one-step rapid diagnostic tool for JEV, especially in rural areas.
Collapse
Affiliation(s)
- Akanksha Roberts
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| | - Himani Dhanze
- ICAR‐Indian Veterinary Research Institute (IVRI)IzatnagarUttar PradeshIndia
| | - G. Taru Sharma
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| | - Sonu Gandhi
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| |
Collapse
|
7
|
Kim DH, Park JK, Lee A, Kim SC, Chae JH, Lee M, Lee SG, Lee BW, Yun WS. Highly Selective Electrochemical Quantitation of Creatinine based on its Chemical Reaction with 3,5-Dinitrobenzoate. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
|
8
|
Chouhan RS, Shah M, Prakashan D, P R R, Kolhe P, Gandhi S. Emerging Trends and Recent Progress of MXene as a Promising 2D Material for Point of Care (POC) Diagnostics. Diagnostics (Basel) 2023; 13:697. [PMID: 36832187 PMCID: PMC9955873 DOI: 10.3390/diagnostics13040697] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 01/27/2023] [Accepted: 02/08/2023] [Indexed: 02/17/2023] Open
Abstract
Two-dimensional (2D) nanomaterials with chemical and structural diversity have piqued the interest of the scientific community due to their superior photonic, mechanical, electrical, magnetic, and catalytic capabilities that distinguish them from their bulk counterparts. Among these 2D materials, two-dimensional (2D) transition metal carbides, carbonitrides, and nitrides with a general chemical formula of Mn+1XnTx (where n = 1-3), together known as MXenes, have gained tremendous popularity and demonstrated competitive performance in biosensing applications. In this review, we focus on the cutting-edge advances in MXene-related biomaterials, with a systematic summary on their design, synthesis, surface engineering approaches, unique properties, and biological properties. We particularly emphasize the property-activity-effect relationship of MXenes at the nano-bio interface. We also discuss the recent trends in the application of MXenes in accelerating the performance of conventional point of care (POC) devices towards more practical approaches as the next generation of POC tools. Finally, we explore in depth the existing problems, challenges, and potential for future improvement of MXene-based materials for POC testing, with the goal of facilitating their early realization of biological applications.
Collapse
Affiliation(s)
- Raghuraj Singh Chouhan
- Department of Environmental Sciences, Institute “Jožef Stefan”, Jamova 39, 1000 Ljubljana, Slovenia
| | - Maitri Shah
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, India
| | - Drishya Prakashan
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, India
- RCB-Regional Centre for Biotechnology, Faridabad 121001, India
| | - Ramya P R
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, India
- RCB-Regional Centre for Biotechnology, Faridabad 121001, India
| | - Pratik Kolhe
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, India
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, India
- RCB-Regional Centre for Biotechnology, Faridabad 121001, India
| |
Collapse
|
9
|
Wang A, Zhou Y, Chen Y, Zhou J, You X, Liu H, Liu Y, Ding P, Qi Y, Liang C, Zhu X, Zhang Y, Liu E, Zhang G. Electrochemical immunosensor for ultrasensitive detection of human papillomaviruse type 16 L1 protein based on Ag@AuNPs-GO/SPA. Anal Biochem 2023; 660:114953. [PMID: 36243135 DOI: 10.1016/j.ab.2022.114953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/30/2022] [Accepted: 10/07/2022] [Indexed: 12/14/2022]
Abstract
Human papillomaviruse type 16 (HPV16) is a high-risk serotype. As the main protective antigen protein, L1 protein is also the target protein for diagnosis. A simple label free electrochemical immunosensor (ECIS) was fabricated for ultrasensitive detection of HPV16 L1 protein in this work. Quasi-spherical Ag@Au core-shell nanoparticles on graphene oxide (Ag@AuNPs-GO) was developed as current response amplifier and characterized by UV-Vis Spectroscopy, Transmission Electron Microscopy and energy dispersive X-ray spectroscopy. Staphylococcal protein A was decorated on the modified electrode and utilized to immobilized the Fc portion of the monoclonal antibody specific for HPV16 L1 protein. Cyclic Voltammetry, Differential Pulse Voltammetry and Electrochemical Impedance Spectroscopy were used to verify the electrochemical performance and interfacial kinetic property. The increased concentration of HPV16 L1 protein led to slow electron transport and linearly decreased differential pulse voltammetry peak current with a detection limit of 0.002 ng mL-1 and a wide linear relationship in the range of 0.005-400 ng mL-1at a regression coefficient (R2) of 0.9948. Furthermore, this ECIS demonstrated acceptable accuracy with good reproducibility, stability and selectivity, suggesting a promising immunological strategy for HPV typing and early screening.
Collapse
Affiliation(s)
- Aiping Wang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China; College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002, China
| | - Yiting Zhou
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Yumei Chen
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Jingming Zhou
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Xiaojuan You
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Hongliang Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Yankai Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Peiyang Ding
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Yanhua Qi
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Chao Liang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Xifang Zhu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Ying Zhang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Enping Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China
| | - Gaiping Zhang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450000, China; Longhu Laboratory, Zhengzhou, 451100, China; School of Advanced Agricultural Sciences, Peking University, Beijing, 100871, China; College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002, China.
| |
Collapse
|
10
|
Byakodi M, Shrikrishna NS, Sharma R, Bhansali S, Mishra Y, Kaushik A, Gandhi S. Emerging 0D, 1D, 2D, and 3D nanostructures for efficient point-of-care biosensing. BIOSENSORS & BIOELECTRONICS: X 2022; 12:100284. [PMID: 36448023 PMCID: PMC9691282 DOI: 10.1016/j.biosx.2022.100284] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 04/12/2023]
Abstract
The recent COVID-19 infection outbreak has raised the demand for rapid, highly sensitive POC biosensing technology for intelligent health and wellness. In this direction, efforts are being made to explore high-performance nano-systems for developing novel sensing technologies capable of functioning at point-of-care (POC) applications for quick diagnosis, data acquisition, and disease management. A combination of nanostructures [i.e., 0D (nanoparticles & quantum dots), 1D (nanorods, nanofibers, nanopillars, & nanowires), 2D (nanosheets, nanoplates, nanopores) & 3D nanomaterials (nanocomposites and complex hierarchical structures)], biosensing prototype, and micro-electronics makes biosensing suitable for early diagnosis, detection & prevention of life-threatening diseases. However, a knowledge gap associated with the potential of 0D, 1D, 2D, and 3D nanostructures for the design and development of efficient POC sensing is yet to be explored carefully and critically. With this focus, this review highlights the latest engineered 0D, 1D, 2D, and 3D nanomaterials for developing next-generation miniaturized, portable POC biosensors development to achieve high sensitivity with potential integration with the internet of medical things (IoMT, for miniaturization and data collection, security, and sharing), artificial intelligence (AI, for desired analytics), etc. for better diagnosis and disease management at the personalized level.
Collapse
Affiliation(s)
- Manisha Byakodi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
| | - Narlawar Sagar Shrikrishna
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, 121001, Haryana (NCR Delhi), India
| | - Riya Sharma
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
| | - Shekhar Bhansali
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL, 33174, USA
| | - Yogendra Mishra
- Mads Clausen Institute, NanoSYD, University of Southern Denmark, Alsion 2, 6400, Sønderborg, Denmark
| | - Ajeet Kaushik
- NanoBioTech Laboratory, Department of Environmental Engineering, Florida Polytechnic University, Lakeland, FL, USA
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, 121001, Haryana (NCR Delhi), India
| |
Collapse
|
11
|
Shah M, Kolhe P, Roberts A, Shrikrishna NS, Gandhi S. Ultrasensitive immunosensing of Penicillin G in food samples using reduced graphene oxide (rGO) decorated electrode surface. Colloids Surf B Biointerfaces 2022; 219:112812. [PMID: 36088829 DOI: 10.1016/j.colsurfb.2022.112812] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 08/23/2022] [Accepted: 08/25/2022] [Indexed: 01/02/2023]
Abstract
The impact of uncontrolled antibiotic use in animals has subsequently led to emergence of antibiotic-resistant bacteria among humans due to consumption of animal by-products. Hence, to investigate antibiotic contamination in animal origin food products, we have developed a reduced graphene oxide (rGO) based immunosensor using fabricated electrode conjugated with anti-Penicillin antibody (rGO/Pen-Ab) for sensitive detection of Penicillin G. To execute this, Penicillin was first conjugated with Bovine Serum Albumin (BSA) which was confirmed via chromatographic, spectroscopic and electrophoretic-based techniques against both the in-house developed Penicillin conjugate (Pen-BSA) as well as the commercial Penicillin conjugate (Com-Pen-BSA). Further, we fabricated electrode based on one step synthesized rGO and immobilized with antibodies generated against Pen-BSA (Pen-Ab), and Com-Pen-BSA (Com-Pen-Ab), separately for detection of Penicillin. Each synthesis and conjugation step was confirmed by different spectroscopic methods. For efficient working of the electrode, various parameters were optimized using Voltammetry. The limit of detection for Penicillin G against Pen-Ab and Com-Pen-Ab was determined as 0.724 pM and 0.668 pM respectively and both displayed negligible cross reactivity against other β-lactam antibiotics (Cefalexin and Ampicillin). Furthermore, antibiotics were also detected in spiked milk, egg and meat samples and the electrode was evaluated for repeatability and storage stability. In conclusion, in-house developed Pen-Ab showed better sensitivity as compared to Com-Pen-Ab. The fabricated rGO/Pen-Ab biosensor shows future potential for rapid detection of penicillin and other β-lactam antibiotics for safe consumption of animal by-products in humans.
Collapse
Affiliation(s)
- Maitri Shah
- DBT -National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | - Pratik Kolhe
- DBT -National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | - Akanksha Roberts
- DBT -National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India
| | | | - Sonu Gandhi
- DBT -National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India.
| |
Collapse
|
12
|
Roberts A, Gandhi S. A brief review on novel biomarkers identified and advanced biosensing technologies developed for rapid diagnosis of Japanese Encephalitis Virus. PROCEEDINGS OF THE INDIAN NATIONAL SCIENCE ACADEMY 2022. [PMCID: PMC9483901 DOI: 10.1007/s43538-022-00113-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Advanced biosensor technology research is imperative for the management of infectious disease outbreaks such as Japanese Encephalitis (JE), a zoonotic disease caused by the flavivirus JE virus (JEV) which is transmitted to humans (dead-end hosts) from the amplification host, pigs, via mosquitoes. To avoid future pandemic scenarios, proactive research rather than responsive research in the field of diagnostics is a requirement for development of rapid, sensitive and specific screening detection methods. In this mini-review, we have critically compared and evaluated the different types of biomarkers (antigen, antibody, nucleic acid) identified for JEV diagnostics and their specific roles in the manifestation of the infection which may be potentially used for therapeutics and drug development as no treatment is available for JE. Furthermore, different biosensors developed for the detection of JEV biomarkers have been discussed in detail to give an overview of the working principles (electrochemical, optical, etc.), fabrication components (signal amplifier, bioreceptor, etc.), detection limits and response times. This review provides a compact compiled base on available JEV diagnostic research work being currently carried out along with their limitations, future prospective, and major challenges faced. This will enable future development of rapid point-of-care diagnostic screening methods for JEV infection management, which may help reduce number of fatalities.
Collapse
Affiliation(s)
- Akanksha Roberts
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, Telangana 500032 India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, Haryana 121001 India
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, Telangana 500032 India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, Haryana 121001 India
| |
Collapse
|
13
|
Roberts A, Prakashan D, Dhanze H, Gandham RK, Gandhi S, Sharma GT. Immuno-chromatic probe based lateral flow assay for point-of-care detection of Japanese encephalitis virus NS1 protein biomarker in clinical samples using a smartphone-based approach. NANOSCALE ADVANCES 2022; 4:3966-3977. [PMID: 36133331 PMCID: PMC9470087 DOI: 10.1039/d2na00463a] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 08/08/2022] [Indexed: 05/08/2023]
Abstract
Lateral flow assays (LFAs) are one of the most economical, point-of-care (PoC) diagnostic assays that exploit the colorimetric properties of gold nanoparticles (AuNPs). Up to the best of our knowledge, no rapid antigen-based LFA exists for Japanese Encephalitis Virus (JEV) detection. Herein, we have reported a novel portable sandwich-type LFA for on-site detection of the non-structural 1 (NS1) secretory protein of JEV. In-house JEV NS1 antibodies (Abs) were generated and labelled with AuNPs as immunoprobes. A glass fibre membrane conjugate pad was soaked with AuNPs-Ab solution, while the JEV NS1 Ab and anti-rabbit IgG 2° Ab were coated as the test and control lines, respectively, on a nitrocellulose (NC) membrane. Different layers of the LFA were fabricated and various parameters were standardised for optimum colour intensity development. JEV negative serum samples spiked with JEV NS1 Ags (linear range - 1 pg ml-1 to 1 μg ml-1) were applied onto the sample pad and the intensity of the red colour developed on the test line increased with increasing concentration of Ag. The visual limit of detection (LOD) determined from the LFA was 10 pg ml-1, which corresponded to the LOD determined by the graphical data obtained from ImageJ software and the Colorimeter smartphone application. Furthermore, the colorimetric based immunosensor showed minimal non-specific detection of other closely related flaviviral NS1 Ags in the spiked serum, provided a rapid result within 10 min, showed storage stability up to a month at 4 °C, successfully detected the JEV NS1 protein in clinically infected pig serum samples, and hence, may be developed into a PoC screening diagnostic kit for JEV.
Collapse
Affiliation(s)
- Akanksha Roberts
- DBT-National Institute of Animal Biotechnology (NIAB) Hyderabad-500032 Telangana India +91-040-23120127
- DBT-Regional Centre for Biotechnology (RCB) Faridabad-121001 Haryana India
| | - Drishya Prakashan
- DBT-National Institute of Animal Biotechnology (NIAB) Hyderabad-500032 Telangana India +91-040-23120127
- DBT-Regional Centre for Biotechnology (RCB) Faridabad-121001 Haryana India
| | - Himani Dhanze
- ICAR-Indian Veterinary Research Institute (IVRI) Bareilly-243122 Uttar Pradesh India
| | - Ravi Kumar Gandham
- ICAR-Indian Veterinary Research Institute (IVRI) Bareilly-243122 Uttar Pradesh India
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB) Hyderabad-500032 Telangana India +91-040-23120127
- DBT-Regional Centre for Biotechnology (RCB) Faridabad-121001 Haryana India
| | - G Taru Sharma
- DBT-National Institute of Animal Biotechnology (NIAB) Hyderabad-500032 Telangana India +91-040-23120127
| |
Collapse
|
14
|
Kolhe P, Roberts A, Gandhi S. Fabrication of an ultrasensitive electrochemical immunosensor coupled with biofunctionalized zero-dimensional graphene quantum dots for rapid detection of cephalexin. Food Chem 2022; 398:133846. [DOI: 10.1016/j.foodchem.2022.133846] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 07/05/2022] [Accepted: 07/31/2022] [Indexed: 12/18/2022]
|