1
|
Dip A, Mozayani A. Evaluation of the Compatibility of Ethyl Glucuronide and Ethyl Sulphate Levels to Assess Alcohol Consumption in Decomposed and Diabetic Postmortem Cases. J Anal Toxicol 2021; 45:878-884. [PMID: 34086901 DOI: 10.1093/jat/bkab061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/22/2021] [Accepted: 06/03/2021] [Indexed: 11/14/2022] Open
Abstract
The aim of the study is to evaluate the contribution of ethanol metabolite detection in postmortem cases by showing the connection between the presence of ethanol metabolites, which are indicators of alcohol consumption, and the detection of potential postmortem ethanol formation in decomposed and diabetic cases. Determination of ethanol consumption before death is often one of the most important questions in death investigations. Postmortem ethanol formation or degradation products in the blood make it difficult to distinguish antemortem consumption or postmortem formation of ethanol and eventually may lead to misinterpretation. Decomposed bodies and diabetic cases are vulnerable to postmortem ethanol formation due to putrefaction, fermentation or other degradations. Ethyl glucuronide (EtG) and ethyl sulphate (EtS) are two metabolites of ethanol produced only in the antemortem time interval. In this study, EtG and EtS levels in urine and vitreous humor samples of 27 postmortem cases, including diabetic and degraded bodies were compared to ethanol results of their blood, urine, and vitreous humor samples. EtG and EtS in urine and vitreous humor were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS-MS) and ethanol was assayed by routine headspace gas chromatography-flame ionization detector (GC-FID). These cases were devoid of other influences from forensically relevant drugs, so ethanol and/or glucose were among the only positive findings in these cases. The results of this pilot study indicate the postmortem ethanol concentrations do not correlate with the measured EtG and EtS values but are beneficial in rulings of accidental or natural deaths. This preliminary study gives additional data to help distinguish between antemortem ethanol intake and postmortem formation. EtG and EtS were well correlated positively with antemortem ethanol use instead of forming spontaneously in samples from decedents who are decomposing or have a history of diabetic hyperglycemia.
Collapse
Affiliation(s)
- Aybike Dip
- Council of Forensic Medicine, Chemistry Department, Turkey Ministry of Justice, 01120 Adana, Turkey
| | - Ashraf Mozayani
- Department of Administration of Justice, Texas Southern University, 3100 Cleburne Street, Houston, Texas 77004, USA
| |
Collapse
|
2
|
Erkmen C, Gebrehiwot WH, Uslu B. Hydrophilic Interaction Liquid Chromatography (HILIC): Latest Applications in the Pharmaceutical Researches. CURR PHARM ANAL 2021. [DOI: 10.2174/1573412916666200402101501] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background:
Significant advances have been occurred in analytical research since the 1970s
by Liquid Chromatography (LC) as the separation method. Reverse Phase Liquid Chromatography
(RPLC) method, using hydrophobic stationary phases and polar mobile phases, is the most commonly
used chromatographic method. However, it is difficult to analyze some polar compounds with this
method. Another separation method is the Normal Phase Liquid Chromatography (NPLC), which involves
polar stationary phases with organic eluents. NPLC presents low-efficiency separations and
asymmetric chromatographic peak shapes when analyzing polar compounds. Hydrophilic Interaction
Liquid Chromatography (HILIC) is an interesting and promising alternative method for the analysis of
polar compounds. HILIC is defined as a separation method that combines stationary phases used in the
NPLC method and mobile phases used in the RPLC method. HILIC can be successfully applied to all
types of liquid chromatographic separations such as pharmaceutical compounds, small molecules, metabolites,
drugs of abuse, carbohydrates, toxins, oligosaccharides, peptides, amino acids and proteins.
Objective:
This paper provides a general overview of the recent application of HILIC in the pharmaceutical
research in the different sample matrices such as pharmaceutical dosage form, plasma, serum,
environmental samples, animal origin samples, plant origin samples, etc. Also, this review focuses on
the most recent and selected papers in the drug research from 2009 to the submission date in 2020,
dealing with the analysis of different components using HILIC.
Results and Conclusion:
The literature survey showed that HILIC applications are increasing every
year in pharmaceutical research. It was found that HILIC allows simultaneous analysis of many compounds
using different detectors.
Collapse
Affiliation(s)
- Cem Erkmen
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| | | | - Bengi Uslu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| |
Collapse
|
3
|
Dengiz H, Daglioglu N, Goren IE. Assessment of recent alcohol consumption by detecting ethyl glucuronide and ethyl sulphate level among traffic accident patients. TRAFFIC INJURY PREVENTION 2020; 21:371-374. [PMID: 32496812 DOI: 10.1080/15389588.2020.1767777] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 05/04/2020] [Accepted: 05/07/2020] [Indexed: 06/11/2023]
Abstract
Objective: This study aims to explain whether EtG and EtS, which are two non-oxidative ethanol metabolites secreted by the liver and used as markers of alcohol intake related to an incident, were also present in whole blood samples of patients with traffic accident injuries.Methods: EtG and EtS concentrations in all of the whole blood samples were sent to the Forensic Medicine Department of Cukurova University for testing Blood Alcohol Concentrations (BAC) via validated liquid chromatography-tandem mass spectrometer method.Results: The scope of the study covers 200 patients that were admitted to medical services within 12 h following the incident. Of all patients 16.5% were found to be BAC positive, while 35.5 and 23.5 were positive for EtG and EtS, respectively. All samples with a positive BAC result were also positive for EtG and EtS.Conclusion: Detection of EtG and EtS, minor metabolites along with ethanol in the blood can serve as an objective tool to provide further analysis regarding alcohol-related traffic accidents at emergency services.
Collapse
Affiliation(s)
- Huseyin Dengiz
- Department of Forensic Medicine, Faculty of Medicine, Cukurova University, Adana, Turkey
| | - Nebile Daglioglu
- Department of Forensic Medicine, Faculty of Medicine, University of Cukurova, Adana, Turkey
| | - Ismail Ethem Goren
- Department of Forensic Medicine, Faculty of Medicine, Cukurova University, Adana, Turkey
| |
Collapse
|
4
|
Müller A, Iwersen-Bergmann S. Determination of ethyl glucuronide in human hair samples: Decontamination vs extraction. Drug Test Anal 2020; 12:948-956. [PMID: 32171047 DOI: 10.1002/dta.2791] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 02/28/2020] [Accepted: 03/10/2020] [Indexed: 01/02/2023]
Abstract
Decontamination of samples prior to analysis is common practice and recommended for ethyl glucuronide (EtG) hair testing. The aim of this study was to evaluate the applied decontamination procedure during routine hair EtG analysis by monitoring the ethyl glucuronide concentrations in the washing solutions from a representative cohort of individual hair samples. Hair samples from 150 individuals were tested for hair EtG by a validated routine procedure (liquid chromatography/tandem mass spectrometry). A four-step decontamination procedure (ethanol, water, acetone, dichloromethane) was applied to all samples prior to analysis. Hair samples from 20 individuals were analyzed along with the complete set of individual washing solutions. Hair samples from an additional 130 individuals were analyzed along with the corresponding aqueous wash fraction only. No EtG was detected in the washing solutions from hair samples that tested negative for EtG (n = 42). Hair samples positive for ethyl glucuronide (n = 108) were found to liberate different amounts of EtG during decontamination: whereas no, or low portions of, EtG (< 10% of extracted hair EtG) were found in the corresponding washing solutions of the majority (n = 91) of individual samples, there was a minority of samples (n = 6) with more than half of the extracted hair EtG present in the decontamination solvent. No correlation of the decontaminated amount of EtG and the extracted hair EtG was observed. Further experimental studies are necessary to investigate if the observed easily removable fraction of EtG is associated with external contamination and if analysis of wash solutions could be helpful for identifying external contamination in hair testing for ethyl glucuronide.
Collapse
Affiliation(s)
- Alexander Müller
- Department of Legal Medicine, Toxicology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Stefanie Iwersen-Bergmann
- Department of Legal Medicine, Toxicology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
5
|
Biondi A, Freni F, Carelli C, Moretti M, Morini L. Ethyl glucuronide hair testing: A review. Forensic Sci Int 2019; 300:106-119. [PMID: 31096163 DOI: 10.1016/j.forsciint.2019.05.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 04/29/2019] [Accepted: 05/01/2019] [Indexed: 12/18/2022]
Abstract
Ethyl glucuronide (EtG) is a minor, non-oxidative ethanol metabolite that can be detected in several matrices (e.g. blood, urine, hair, meconium) for variable periods of time. Quantification of EtG in hair (hEtG) has established itself, over recent years, as one of the most reliable biomarkers of long-term alcohol consumption habits, with the Society of Hair Testing (SoHT) offering cut-off values for assessment of both abstinence and heavy drinking (>60 g/day). Despite its high diagnostic performance, however, issues concerning inter- and intra-laboratory variability as well as data interpretation are still being investigated and represent the ultimate barrier to widespread acceptance of hEtG in the forensic context. The aim of this review is to summarize currently available analytical methods of hEtG testing, provide a framework to understand current hEtG cut-offs and their possible upcoming changes (in particular, a lower abstinence cut-off has been proposed for the 2019 revision of the SoHT consensus), and offer a schematic but exhaustive overview of the pitfalls in result reproducibility and interpretation that may limit applications of hEtG testing in the forensic context. Ultimately, the purpose of the authors is not to undermine the reliability of hEtG as an alcohol use marker, but rather to enhance it by promoting familiarization with all aspects related to it, from ethanol pharmacokinetics and EtG incorporation into hair, to sample preparation and analytical methods, to specific cases warranting close attention and additional tests for correct interpretation of hEtG results.
Collapse
Affiliation(s)
- Anna Biondi
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy
| | - Francesca Freni
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy
| | - Claudia Carelli
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy
| | - Matteo Moretti
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy
| | - Luca Morini
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, Pavia, Italy.
| |
Collapse
|
6
|
Bioanalytical procedures and developments in the determination of alcohol biomarkers in biological specimens. Bioanalysis 2016; 8:229-51. [DOI: 10.4155/bio.15.240] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Excessive alcohol consumption is a global problem, and consequently its evaluation is of great clinical and forensic interest. Alcohol biomarkers have been the focus of several research works in the past decades, with new compounds being studied in more recent years. The main objective of this review is to discuss topics for an analyst to consider when evaluating alcohol consumption through the analysis of alcohol biomarkers in biological specimens. For this, existing alcohol biomarkers will be reviewed, including carbohydrate-deficient transferrin, 5-hydroxytryptophol, ethanol, hemoglobin-associated acetaldehyde, fatty acid ethyl esters, ethyl glucuronide, ethyl sulfate and phosphatidylethanol. Additionally, their potential will be discussed, as well as analytical considerations, main challenges, limitations, data interpretation and existing methodologies for their determination in biological specimens.
Collapse
|
7
|
Nanau RM, Neuman MG. Biomolecules and Biomarkers Used in Diagnosis of Alcohol Drinking and in Monitoring Therapeutic Interventions. Biomolecules 2015; 5:1339-85. [PMID: 26131978 PMCID: PMC4598755 DOI: 10.3390/biom5031339] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Revised: 05/15/2015] [Accepted: 05/29/2015] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND The quantitative, measurable detection of drinking is important for the successful treatment of alcohol misuse in transplantation of patients with alcohol disorders, people living with human immunodeficiency virus that need to adhere to medication, and special occupational hazard offenders, many of whom continually deny drinking. Their initial misconduct usually leads to medical problems associated with drinking, impulsive social behavior, and drunk driving. The accurate identification of alcohol consumption via biochemical tests contributes significantly to the monitoring of drinking behavior. METHODS A systematic review of the current methods used to measure biomarkers of alcohol consumption was conducted using PubMed and Google Scholar databases (2010-2015). The names of the tests have been identified. The methods and publications that correlate between the social instruments and the biochemical tests were further investigated. There is a clear need for assays standardization to ensure the use of these biochemical tests as routine biomarkers. FINDINGS Alcohol ingestion can be measured using a breath test. Because alcohol is rapidly eliminated from the circulation, the time for detection by this analysis is in the range of hours. Alcohol consumption can alternatively be detected by direct measurement of ethanol concentration in blood or urine. Several markers have been proposed to extend the interval and sensitivities of detection, including ethyl glucuronide and ethyl sulfate in urine, phosphatidylethanol in blood, and ethyl glucuronide and fatty acid ethyl esters in hair, among others. Moreover, there is a need to correlate the indirect biomarker carbohydrate deficient transferrin, which reflects longer lasting consumption of higher amounts of alcohol, with serum γ-glutamyl transpeptidase, another long term indirect biomarker that is routinely used and standardized in laboratory medicine.
Collapse
Affiliation(s)
- Radu M Nanau
- In Vitro Drug Safety and Biotechnology, University of Toronto, Toronto, ON M5G 0A3, Canada.
| | - Manuela G Neuman
- In Vitro Drug Safety and Biotechnology, University of Toronto, Toronto, ON M5G 0A3, Canada.
- Department of Pharmacology and Toxicology, Faculty of Medicine, University of Toronto, Toronto, ON M5G 0A3, Canada.
| |
Collapse
|
8
|
Abstract
Alcohol misuse is associated with significant morbidity and mortality. Although clinical history, examination, and the use of self-report questionnaires may identify subjects with harmful patterns of alcohol use, denial or under-reporting of alcohol intake is common. Existing biomarkers for detecting alcohol misuse include measurement of blood or urine ethanol for acute alcohol consumption, and carbohydrate-deficient transferrin and gamma-glutamyl transferase for chronic alcohol misuse. There is a need for a biomarker that can detect excessive alcohol consumption in the timeframe between 1 day and several weeks. Ethyl glucuronide (EtG) is a direct metabolite of ethanol detectable in urine for up to 90 h and longer in hair. Because EtG has high specificity for excess alcohol intake, it has great potential for use in detecting "binge" drinking. Using urine or hair, this noninvasive marker has a role in a variety of clinical and forensic settings.
Collapse
Affiliation(s)
- Natalie E Walsham
- Department of Clinical Biochemistry, University Hospital Lewisham, London, United Kingdom
| | - Roy A Sherwood
- Department of Clinical Biochemistry, King's College Hospital NHS Foundation Trust, London, United Kingdom.
| |
Collapse
|