1
|
Loke YH, Yildiran IN, Capuano F, Balaras E, Olivieri L. Tetralogy of Fallot regurgitation energetics and kinetics: an intracardiac flow analysis of the right ventricle using computational fluid dynamics. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024; 40:1135-1147. [PMID: 38668927 DOI: 10.1007/s10554-024-03084-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 03/11/2024] [Indexed: 06/05/2024]
Abstract
Repaired Tetralogy of Fallot (rTOF) patients suffer from pulmonary regurgitation and may require pulmonary valve replacement (PVR). Cardiac magnetic resonance imaging (cMRI) guides therapy, but conventional measurements do not quantify the intracardiac flow effects from pulmonary regurgitation or PVR. This study investigates intracardiac flow parameters of the right ventricle (RV) of rTOF by computational fluid dynamics (CFD). cMRI of rTOF patients and controls were retrospectively included. Feature-tracking captured RV endocardial contours from long-axis/short-axis cine. Ventricular motion was reconstructed via diffeomorphic mapping, serving as domain boundary for CFD simulations. Vorticity (1/s), viscous energy loss (ELoss, mJ/L) and turbulent kinetic energy (TKE, mJ/L) were quantified in RV outflow tract (RVOT) and RV inflow. These parameters were normalized against total RV kinetic energy (KE) and RV inflow vorticity to derive dimensionless metrics. Vorticity contours by Q-criterion were qualitatively compared. rTOF patients (n = 15) had mean regurgitant fraction 38 ± 12% and RV size 162 ± 35 mL/m2. Compared to controls (n = 12), rTOF had increased RVOT vorticity (142.6 ± 75.6/s vs. 40.4 ± 11.8/s, p < 0.0001), Eloss (55.6 ± 42.5 vs. 5.2 ± 4.4 mJ/L, p = 0.0004), and TKE (5.7 ± 5.9 vs. 0.84 ± 0.46 mJ/L, p = 0.0003). After PVR, there was decrease in normalized RVOT Eloss/TKE (p = 0.0009, p = 0.029) and increase in normalized tricuspid inflow vorticity/KE (p = 0.0136, p = 0.043), corresponding to reorganization of the "donut"-shaped tricuspid ring-vortex. The intracardiac flow in rTOF patients can be simulated to determine the impact of PVR and improve the clinical indications guided by cardiac imaging.
Collapse
Affiliation(s)
- Yue-Hin Loke
- Department of Cardiology, Children's National Hospital, 111 Michigan Ave NW, Washington, DC, 20010, USA.
| | - Ibrahim N Yildiran
- Laboratory for Computational Physics and Fluid Mechanics, Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, USA
| | - Francesco Capuano
- Department of Fluid Mechanics, Universitat Politècnica de Catalunya . BarcelonaTech (UPC), Barcelona, Spain
| | - Elias Balaras
- Laboratory for Computational Physics and Fluid Mechanics, Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, USA
| | - Laura Olivieri
- The Heart and Vascular Institute, UPMC Children's Hospital of Pittsburgh, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| |
Collapse
|
2
|
Meyers B, Nyce J, Zhang J, Frank LH, Balaras E, Vlachos PP, Loke YH. Intracardiac Flow Analysis of the Right Ventricle in Pediatric Patients With Repaired Tetralogy of Fallot Using a Novel Color Doppler Velocity Reconstruction. J Am Soc Echocardiogr 2023; 36:644-653. [PMID: 36822439 PMCID: PMC10247486 DOI: 10.1016/j.echo.2023.02.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 02/08/2023] [Accepted: 02/10/2023] [Indexed: 02/25/2023]
Abstract
BACKGROUND Repaired tetralogy of Fallot (RTOF) patients will develop right ventricular (RV) dysfunction from chronic pulmonary regurgitation (PR). Cardiac magnetic resonance sequences such as four-dimensional flow can demonstrate altered vorticity and flow energy loss (FEL); however, they are not as available as conventional echocardiography (echo). The study determined whether a novel, vendor-independent Doppler velocity reconstruction (DoVeR) could measure RV intracardiac flow in conventional echo of RTOF patients. The primary hypothesis was that DoVeR could detect increased vorticity and diastolic FEL in RTOF patients. METHODS Repaired tetralogy of Fallot patients with echo were retrospectively paired with age-/size-matched controls. Doppler velocity reconstruction employed the stream function-vorticity equation to approximate intracardiac flow fields from color Doppler. A velocity field of the right ventricle was reconstructed from the apical 4-chamber view. Vortex strength (VS, area integral of vorticity) and FEL were derived from DoVeR. Cardiac magnetic resonance and exercise stress parameters (performed within 1 year of echo) were collected for analysis. RESULTS Twenty RTOF patients and age-matched controls were included in the study. Mean regurgitant fraction was 40.5% ± 7.6%, and indexed RV end-diastolic volume was 158 ± 36 mL/m2. Repaired tetralogy of Fallot patients had higher total, mean diastolic, and peak diastolic VS (P = .0013, P = .0012, P = .0032, respectively) and higher total, mean diastolic, and peak diastolic body surface area-indexed FEL (P = .0016, P = .0022, P < .001, respectively). Peak diastolic indexed FEL and peak diastolic VS had weak-to-moderate negative correlation with RV ejection fraction (r = -0.52 [P = .019] and r = -0.49 [P = .030], respectively) and left ventricular ejection fraction (r = -0.47 [P = .034] and r = -0.64 [P = .002], respectively). Mean diastolic indexed FEL and VS had moderate-to-strong negative correlation with percent predicted maximal oxygen consumption (r = -0.69 [P = .012] and r = -0.75 [P = .006], respectively). CONCLUSIONS DoVeR can detect alterations to intracardiac flow in RTOF patients from conventional color Doppler imaging. Echo-based measures of diastolic VS and FEL correlated with ventricular function. DoVeR has the potential to provide serial evaluation of abnormal flow dynamics in RTOF patients.
Collapse
Affiliation(s)
- Brett Meyers
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana
| | - Jonathan Nyce
- Department of Cardiology, Children's National Hospital, Washington, D.C
| | - Jiacheng Zhang
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana
| | - Lowell H Frank
- Department of Cardiology, Children's National Hospital, Washington, D.C
| | - Elias Balaras
- School of Engineering & Applied Science, George Washington University, Washington, D.C
| | - Pavlos P Vlachos
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana
| | - Yue-Hin Loke
- Department of Cardiology, Children's National Hospital, Washington, D.C..
| |
Collapse
|
3
|
Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review. J Cardiovasc Dev Dis 2022; 9:jcdd9090304. [PMID: 36135449 PMCID: PMC9503592 DOI: 10.3390/jcdd9090304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 09/07/2022] [Accepted: 09/09/2022] [Indexed: 11/17/2022] Open
Abstract
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as “highly clinically applicable”. There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.
Collapse
|
4
|
Ashkir Z, Myerson S, Neubauer S, Carlhäll CJ, Ebbers T, Raman B. Four-dimensional flow cardiac magnetic resonance assessment of left ventricular diastolic function. Front Cardiovasc Med 2022; 9:866131. [PMID: 35935619 PMCID: PMC9355735 DOI: 10.3389/fcvm.2022.866131] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 06/30/2022] [Indexed: 11/13/2022] Open
Abstract
Left ventricular diastolic dysfunction is a major cause of heart failure and carries a poor prognosis. Assessment of left ventricular diastolic function however remains challenging for both echocardiography and conventional phase contrast cardiac magnetic resonance. Amongst other limitations, both are restricted to measuring velocity in a single direction or plane, thereby compromising their ability to capture complex diastolic hemodynamics in health and disease. Time-resolved three-dimensional phase contrast cardiac magnetic resonance imaging with three-directional velocity encoding known as '4D flow CMR' is an emerging technology which allows retrospective measurement of velocity and by extension flow at any point in the acquired 3D data volume. With 4D flow CMR, complex aspects of blood flow and ventricular function can be studied throughout the cardiac cycle. 4D flow CMR can facilitate the visualization of functional blood flow components and flow vortices as well as the quantification of novel hemodynamic and functional parameters such as kinetic energy, relative pressure, energy loss and vorticity. In this review, we examine key concepts and novel markers of diastolic function obtained by flow pattern analysis using 4D flow CMR. We consolidate the existing evidence base to highlight the strengths and limitations of 4D flow CMR techniques in the surveillance and diagnosis of left ventricular diastolic dysfunction.
Collapse
Affiliation(s)
- Zakariye Ashkir
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Saul Myerson
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Stefan Neubauer
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Carl-Johan Carlhäll
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Betty Raman
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
5
|
Loke YH, Capuano F, Kollar S, Cibis M, Kitslaar P, Balaras E, Reiber JHC, Pedrizzetti G, Olivieri L. Abnormal Diastolic Hemodynamic Forces: A Link Between Right Ventricular Wall Motion, Intracardiac Flow, and Pulmonary Regurgitation in Repaired Tetralogy of Fallot. Front Cardiovasc Med 2022; 9:929470. [PMID: 35911535 PMCID: PMC9329698 DOI: 10.3389/fcvm.2022.929470] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 06/20/2022] [Indexed: 11/25/2022] Open
Abstract
Background and Objective The effect of chronic pulmonary regurgitation (PR) on right ventricular (RV) dysfunction in repaired Tetralogy of Fallot (RTOF) patients is well recognized by cardiac magnetic resonance (CMR). However, the link between RV wall motion, intracardiac flow and PR has not been established. Hemodynamic force (HDF) represents the global force exchanged between intracardiac blood volume and endocardium, measurable by 4D flow or by a novel mathematical model of wall motion. In our study, we used this novel methodology to derive HDF in a cohort of RTOF patients, exclusively using routine CMR imaging. Methods RTOF patients and controls with CMR imaging were retrospectively included. Three-dimensional (3D) models of RV were segmented, including RV outflow tract (RVOT). Feature-tracking software (QStrain 2.0, Medis Medical Imaging Systems, Leiden, Netherlands) captured endocardial contours from long/short-axis cine and used to reconstruct RV wall motion. A global HDF vector was computed from the moving surface, then decomposed into amplitude/impulse of three directional components based on reference (Apical-to-Basal, Septal-to-Free Wall and Diaphragm-to-RVOT direction). HDF were compared and correlated against CMR and exercise stress test parameters. A subset of RTOF patients had 4D flow that was used to derive vorticity (for correlation) and HDF (for comparison against cine method). Results 68 RTOF patients and 20 controls were included. RTOF patients had increased diastolic HDF amplitude in all three directions (p<0.05). PR% correlated with Diaphragm-RVOT HDF amplitude/impulse (r = 0.578, p<0.0001, r = 0.508, p < 0.0001, respectively). RV ejection fraction modestly correlated with global HDF amplitude (r = 0.2916, p = 0.031). VO2-max correlated with Septal-to-Free Wall HDF impulse (r = 0.536, p = 0.007). Diaphragm-to-RVOT HDF correlated with RVOT vorticity (r = 0.4997, p = 0.001). There was no significant measurement bias between Cine-derived HDF and 4D flow-derived HDF by Bland-Altman analysis. Conclusion RTOF patients have abnormal diastolic HDF that is correlated to PR, RV function, exercise capacity and vorticity. HDF can be derived from conventional cine, and is a potential link between RV wall motion and intracardiac flow from PR in RTOF patients.
Collapse
Affiliation(s)
- Yue-Hin Loke
- Department of Cardiology, Children’s National Hospital, Washington, DC, United States
- 3D Cardiac Visualization Laboratory, Sheikh Zayed Institute for Pediatric Surgical Innovation, Children’s National Hospital, Washington, DC, United States
| | - Francesco Capuano
- Department of Fluid Mechanics, Universitat Politècnica de Catalunya BarcelonaTech (UPC), Barcelona, Spain
| | - Sarah Kollar
- Department of Cardiology, Children’s National Hospital, Washington, DC, United States
| | - Merih Cibis
- Medis Medical Imaging Systems, Leiden, Netherlands
| | | | - Elias Balaras
- Laboratory for Computational Physics and Fluid Mechanics, Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, United States
| | | | - Gianni Pedrizzetti
- Department of Engineering and Architecture, University of Trieste, Trieste, Italy
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, United States
| | - Laura Olivieri
- 3D Cardiac Visualization Laboratory, Sheikh Zayed Institute for Pediatric Surgical Innovation, Children’s National Hospital, Washington, DC, United States
- Department of Cardiology, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
6
|
Isoda H, Fukuyama A. Quality Control for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:278-292. [PMID: 35197395 PMCID: PMC9680545 DOI: 10.2463/mrms.rev.2021-0165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023] Open
Abstract
In recent years, 4D flow MRI has become increasingly important in clinical applications for the blood vessels in the whole body, heart, and cerebrospinal fluid. 4D flow MRI has advantages over 2D cine phase-contrast (PC) MRI in that any targeted area of interest can be analyzed post-hoc, but there are some factors to be considered, such as ensuring measurement accuracy, a long imaging time and post-processing complexity, and interobserver variability.Due to the partial volume phenomenon caused by low spatial and temporal resolutions, the accuracy of flow measurement in 4D flow MRI is reduced. For spatial resolution, it is recommended to include at least four voxels in the vessel of interest, and if possible, six voxels. In large vessels such as the aorta, large voxels can be secured and SNR can be maintained, but in small cerebral vessels, SNR is reduced, resulting in reduced accuracy. A temporal resolution of less than 40 ms is recommended. The velocity-to-noise ratio (VNR) of low-velocity blood flow is low, resulting in poor measurement accuracy. The use of dual velocity encoding (VENC) or multi-VENC is recommended to avoid velocity wrap around and to increase VNR. In order to maintain sufficient spatio-temporal resolution, a longer imaging time is required, leading to potential patient movement during examination and a corresponding decrease in measurement accuracy.For the clinical application of new technologies, including various acceleration techniques, in vitro and in vivo accuracy verification based on existing accuracy-validated 2D cine PC MRI and 4D flow MRI, as well as accuracy verification on the conservation of mass' principle, should be performed, and intraobserver repeatability, interobserver reproducibility, and test-retest reproducibility should be checked.
Collapse
Affiliation(s)
- Haruo Isoda
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
- Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Atsushi Fukuyama
- Faculty of Health Sciences, Department of Radiological Sciences, Japan Healthcare University, Sapporo, Hokkaido, Japan
| |
Collapse
|
7
|
Itatani K, Sekine T, Yamagishi M, Maeda Y, Higashitani N, Miyazaki S, Matsuda J, Takehara Y. Hemodynamic Parameters for Cardiovascular System in 4D Flow MRI: Mathematical Definition and Clinical Applications. Magn Reson Med Sci 2022; 21:380-399. [PMID: 35173116 DOI: 10.2463/mrms.rev.2021-0097] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Blood flow imaging becomes an emerging trend in cardiology with the recent progress in computer technology. It not only visualizes colorful flow velocity streamlines but also quantifies the mechanical stress on cardiovascular structures; thus, it can provide the detailed inspections of the pathophysiology of diseases and predict the prognosis of cardiovascular functions. Clinical applications include the comprehensive assessment of hemodynamics and cardiac functions in echocardiography vector flow mapping (VFM), 4D flow MRI, and surgical planning as a simulation medicine in computational fluid dynamics (CFD).For evaluation of the hemodynamics, novel mathematically derived parameters obtained using measured velocity distributions are essential. Among them, the traditional and typical parameters are wall shear stress (WSS) and its related parameters. These parameters indicate the mechanical damages to endothelial cells, resulting in degenerative intimal change in vascular diseases. Apart from WSS, there are abundant parameters that describe the strength of the vortical and/or helical flow patterns. For instance, vorticity, enstrophy, and circulation indicate the rotating flow strength or power of 2D vortical flows. In addition, helicity, which is defined as the cross-linking number of the vortex filaments, indicates the 3D helical flow strength and adequately describes the turbulent flow in the aortic root in cases with complicated anatomies. For the description of turbulence caused by the diseased flow, there exist two types of parameters based on completely different concepts, namely: energy loss (EL) and turbulent kinetic energy (TKE). EL is the dissipated energy with blood viscosity and evaluates the cardiac workload related to the prognosis of heart failure. TKE describes the fluctuation in kinetic energy during turbulence, which describes the severity of the diseases that cause jet flow. These parameters are based on intuitive and clear physiological concepts, and are suitable for in vivo flow measurements using inner velocity profiles.
Collapse
Affiliation(s)
- Keiichi Itatani
- Department of Cardiovascular Surgery, Osaka City University.,Cardio Flow Design Inc
| | - Tetsuro Sekine
- Department of Radiology, Nippon Medical School Musashi Kosugi Hospital
| | - Masaaki Yamagishi
- Department of Pediatric Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | - Yoshinobu Maeda
- Department of Pediatric Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | - Norika Higashitani
- Cardio Flow Design Inc.,Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | | | - Junya Matsuda
- Department of Cardiovascular Medicine, Nippon Medical School
| | - Yasuo Takehara
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya university Graduate School of Medicine
| |
Collapse
|
8
|
Umehara T, Takumi K, Ueda K, Tokunaga T, Harada-Takeda A, Sato M. Hemodynamic features underlying pulmonary vein stump thrombus formation after left upper lobectomy: four-dimensional flow magnetic resonance imaging study. Quant Imaging Med Surg 2022; 12:992-1003. [PMID: 35111600 DOI: 10.21037/qims-21-472] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 09/13/2021] [Indexed: 12/16/2022]
Abstract
BACKGROUND We previously reported that to-and-fro blood movement near the pulmonary vein stump was particularly prominent after left upper lobectomy compared with other lobectomy, which may be the cause of the high susceptibility of pulmonary vein thrombus after left upper lobectomy. The aim of the present study was to compare the hemodynamics in patients who developed pulmonary vein thrombus after left upper lobectomy with those in patients who did not develop pulmonary vein thrombus using four-dimensional flow magnetic resonance imaging (4D MRI). METHODS This was a retrospective evaluation of a prospectively collected clinical and radiological database of 37 patients who underwent 4D MRI 7 days after left upper lobectomy for lung cancer (n=37). We obtained two parameters by 4D MRI: the grade of to-and-fro blood movement and the flow energy loss around the pulmonary vein stump. The length of the pulmonary vein stump, a known risk factor for pulmonary vein thrombus, was also measured. RESULTS According to a scatterplot of the grade of to-and-fro blood movement versus the flow energy loss, patients with pulmonary vein thrombus (n=15) were concentrated in an area which appears to be a 'dangerous' hemodynamic condition. There were few patients without pulmonary vein thrombus in this 'dangerous' area, except for one who unfortunately developed delayed pulmonary vein thrombus and cerebral infarction. We proposed a formula using the 4D MRI-derived parameters based on a stepwise multiple regression analysis that was more closely associated with the development of pulmonary vein thrombus than the length of the pulmonary vein stump (area under the receiver operating characteristics curve: 0.918 vs. 0.705, P=0.0500). CONCLUSIONS We proposed the existence of a 'dangerous' hemodynamic condition responsible for pulmonary vein thrombus formation. 4D MRI before the development of pulmonary vein thrombus may help identify patients requiring preventive therapy against pulmonary vein thrombus and subsequent thromboembolic complications.
Collapse
Affiliation(s)
- Tadashi Umehara
- Department of General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Koji Takumi
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kazuhiro Ueda
- Department of General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Takuya Tokunaga
- Department of General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Aya Harada-Takeda
- Department of General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Masami Sato
- Department of General Thoracic Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| |
Collapse
|
9
|
Zhao X, Hu L, Leng S, Tan RS, Chai P, Bryant JA, Teo LLS, Fortier MV, Yeo TJ, Ouyang RZ, Allen JC, Hughes M, Garg P, Zhang S, van der Geest RJ, Yip JW, Tan TH, Tan JL, Zhong Y, Zhong L. Ventricular flow analysis and its association with exertional capacity in repaired tetralogy of Fallot: 4D flow cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 2022; 24:4. [PMID: 34980199 PMCID: PMC8722058 DOI: 10.1186/s12968-021-00832-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 11/23/2021] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it remains unclear whether 4D flow parameters can predict cardiopulmonary exercise testing (CPET) as a clinical outcome in repaired tetralogy of Fallot (rTOF). Current study aimed to (1) compare 4D flow CMR parameters in rTOF with age- and gender-matched healthy controls, (2) investigate associations of 4D flow parameters with functional and volumetric right ventricular (RV) remodelling markers, and CPET outcome. METHODS Sixty-three rTOF patients (14 paediatric, 49 adult; 30 ± 15 years; 29 M) and 63 age- and gender-matched healthy controls (14 paediatric, 49 adult; 31 ± 15 years) were prospectively recruited at four centers. All underwent cine and 4D flow CMR, and all adults performed standardized CPET same day or within one week of CMR. RV remodelling index was calculated as the ratio of RV to left ventricular (LV) end-diastolic volumes. Four flow components were analyzed: direct flow, retained inflow, delayed ejection flow and residual volume. Additionally, three phasic KE parameters normalized to end-diastolic volume (KEiEDV), were analyzed for both LV and RV: peak systolic, average systolic and peak E-wave. RESULTS In comparisons of rTOF vs. healthy controls, median LV retained inflow (18% vs. 16%, P = 0.005) and median peak E-wave KEiEDV (34.9 µJ/ml vs. 29.2 µJ/ml, P = 0.006) were higher in rTOF; median RV direct flow was lower in rTOF (25% vs. 35%, P < 0.001); median RV delayed ejection flow (21% vs. 17%, P < 0.001) and residual volume (39% vs. 31%, P < 0.001) were both greater in rTOF. RV KEiEDV parameters were all higher in rTOF than healthy controls (all P < 0.001). On multivariate analysis, RV direct flow was an independent predictor of RV function and CPET outcome. RV direct flow and RV peak E-wave KEiEDV were independent predictors of RV remodelling index. CONCLUSIONS In this multi-scanner multicenter 4D flow CMR study, reduced RV direct flow was independently associated with RV dysfunction, remodelling and, to a lesser extent, exercise intolerance in rTOF patients. This supports its utility as an imaging parameter for monitoring disease progression and therapeutic response in rTOF. Clinical Trial Registration https://www.clinicaltrials.gov . Unique identifier: NCT03217240.
Collapse
Affiliation(s)
- Xiaodan Zhao
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
| | - Liwei Hu
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Shuang Leng
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| | - Ru-San Tan
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| | - Ping Chai
- National University Hospital Singapore, Singapore, Singapore
| | - Jennifer Ann Bryant
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| | - Lynette L S Teo
- National University Hospital Singapore, Singapore, Singapore
| | - Marielle V Fortier
- Duke-NUS Medical School, Singapore, Singapore
- KK Women's and Children's Hospital, Singapore, Singapore
- Singapore Institute for Clinical Sciences, A*STAR, Singapore, Singapore
| | - Tee Joo Yeo
- National University Hospital Singapore, Singapore, Singapore
| | - Rong Zhen Ouyang
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | | | - Marina Hughes
- Department of Cardiovascular Medicine, University of East Anglia, Norwich, UK
| | - Pankaj Garg
- Department of Cardiovascular Medicine, University of East Anglia, Norwich, UK
| | - Shuo Zhang
- Philips Healthcare Germany, Hamburg, Germany
| | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
| | - James W Yip
- National University Hospital Singapore, Singapore, Singapore
| | - Teng Hong Tan
- Duke-NUS Medical School, Singapore, Singapore
- KK Women's and Children's Hospital, Singapore, Singapore
| | - Ju Le Tan
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| | - Yumin Zhong
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
| | - Liang Zhong
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore.
- Duke-NUS Medical School, Singapore, Singapore.
| |
Collapse
|
10
|
Loke YH, Capuano F, Cleveland V, Mandell JG, Balaras E, Olivieri LJ. Moving beyond size: vorticity and energy loss are correlated with right ventricular dysfunction and exercise intolerance in repaired Tetralogy of Fallot. J Cardiovasc Magn Reson 2021; 23:98. [PMID: 34412634 PMCID: PMC8377822 DOI: 10.1186/s12968-021-00789-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 06/28/2021] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND The global effect of chronic pulmonary regurgitation (PR) on right ventricular (RV) dilation and dysfunction in repaired Tetralogy of Fallot (rTOF) patients is well studied by cardiovascular magnetic resonance (CMR). However, the links between PR in the RV outflow tract (RVOT), RV dysfunction and exercise intolerance are not clarified by conventional measurements. Not all patients with RV dilation share the same intracardiac flow characteristics, now measurable by time resolved three-dimensional phase contrast imaging (4D flow). In our study, we quantified regional vorticity and energy loss in rTOF patients and correlated these parameters with RV dysfunction and exercise capacity. METHODS rTOF patients with 4D flow datasets were retrospectively analyzed, including those with transannular/infundibular repair and conduit repair. Normal controls and RV dilation patients with atrial-level shunts (Qp:Qs > 1.2:1) were included for comparison. 4D flow was post-processed using IT Flow (Cardioflow, Japan). Systolic/diastolic vorticity (ω, 1/s) and viscous energy loss (VEL, mW) in the RVOT and RV inflow were measured. To characterize the relative influence of diastolic vorticity in the two regions, an RV Diastolic Vorticity Quotient (ωRVOT-Diastole/ωRV Inflow-Diastole, RV-DVQ) was calculated. Additionally, RVOT Vorticity Quotient (ωRVOT-Diastole/ωRVOT-Systole, RVOT-VQ) and RVOT Energy Quotient (VELRVOT-Diastole/VELRVOT-Systole, RVOT-EQ) was calculated. In rTOF, measurements were correlated against conventional CMR and exercise stress test results. RESULTS 58 rTOF patients, 28 RV dilation patients and 12 controls were included. RV-DVQ, RVOT-VQ, and RVOT-EQ were highest in rTOF patients with severe PR compared to rTOF patients with non-severe PR, RV dilation and controls (p < 0.001). RV-DVQ positively correlated with RV end-diastolic volume (0.683, p < 0.001), PR fraction (0.774, p < 0.001) and negatively with RV ejection fraction (- 0.521, p = 0.003). Both RVOT-VQ, RVOT-EQ negatively correlated with VO2-max (- 0.587, p = 0.008 and - 0.617, p = 0.005) and % predicted VO2-max (- 0.678, p = 0.016 and - 0.690, p = 0.001). CONCLUSIONS In rTOF patients, vorticity and energy loss dominate the RVOT compared to tricuspid inflow, correlating with RV dysfunction and exercise intolerance. These 4D flow-based measurements may be sensitive biomarkers to guide surgical management of rTOF patients.
Collapse
Affiliation(s)
- Yue-Hin Loke
- Division of Cardiology, Children's National Medical Center, 111 Michigan Ave NW, W3-200, Washington, DC, 20010, USA.
| | - Francesco Capuano
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Bari, Italy
| | - Vincent Cleveland
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Medical Center, 111 Michigan Ave NW, Washington, DC, 20010, USA
| | - Jason G Mandell
- Division of Cardiology, Children's National Medical Center, 111 Michigan Ave NW, W3-200, Washington, DC, 20010, USA
| | - Elias Balaras
- Department of Mechanical and Aerospace Engineering, George Washington University, Washington, DC, 20052, USA
| | - Laura J Olivieri
- Division of Cardiology, Children's National Medical Center, 111 Michigan Ave NW, W3-200, Washington, DC, 20010, USA
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Medical Center, 111 Michigan Ave NW, Washington, DC, 20010, USA
| |
Collapse
|
11
|
Hohri Y, Itatani K, Matsuo A, Komori Y, Okamoto T, Goto T, Kobayashi T, Hiramatsu T, Miyazaki S, Nishino T, Yaku H. Estimating the Haemodynamic Streamline Vena Contracta as the Effective Orifice Area Measured from Reconstructed Multislice Phase-contrast MR Images for Patients with Moderately Accelerated Aortic Stenosis. Magn Reson Med Sci 2021; 21:569-582. [PMID: 34334586 DOI: 10.2463/mrms.mp.2021-0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In aortic stenosis (AS), the discrepancy between moderately accelerated flow and effective orifice area (EOA) continues to pose a challenge. We developed a method of measuring the vena contracta area as hemodynamic EOA using cardiac MRI focusing on AS patients with a moderately accelerated flow to solve the problem that AS severity can currently be determined only by echocardiography. METHODS We investigated 40 patients with a peak transvalvular velocity > 3.0 m/s on transthoracic echocardiography (TTE). The patients were divided into highly accelerated and moderately accelerated AS groups according to whether or not the peak transvalvular velocity was ≥ 4.0 m/s. From the multislice 2D cine phase-contrast MRI data, the cross-sectional area of the vena contracta of the reconstructed streamline in the Valsalva sinus was defined as MRI-EOAs. Patient symptoms and echocardiography data, including EOA (defined as TTE-EOA), were derived from the continuity equation using TTE. RESULTS All participants in the highly accelerated AS group (n = 19) showed a peak velocity ≥ 4.0 m/s in MRI. Eleven patients in the moderately accelerated AS group (n = 21) had a TTE-EOA < 1.00 cm2. In the moderately accelerated AS group, MRI-EOAs demonstrated a strong correlation with TTE-EOAs (r = 0.76, P < 0.01). Meanwhile, in the highly accelerated AS group, MRI-EOAs demonstrated positivity but a moderate correlation with TTE-EOAs (r = 0.63, P = 0.004). MRI-EOAs were overestimated compared to TTE-EOAs. In terms of the moderately accelerated AS group, the best cut-off value for MRI-EOAs was < 1.23 cm2, compatible with TTE-EOAs < 1.00 cm2, with an excellent prediction of the New York Heart Association classification ≥ III (sensitivity 87.5%, specificity 76.9%). CONCLUSION MRI-EOAs may be an alternative to conventional echocardiography for patients with moderately accelerated AS, especially those with discordant echocardiographic parameters.
Collapse
Affiliation(s)
- Yu Hohri
- Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | | | - Akiko Matsuo
- Department of Cardiology, Japanese Red Cross Kyoto Daini Hospital
| | | | - Takeshi Okamoto
- Department of Radiology, Japanese Red Cross Kyoto Daini Hospital
| | - Tomoyuki Goto
- Department of Cardiovascular Surgery, Japanese Red Cross Kyoto Daini Hospital
| | - Takuma Kobayashi
- Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | - Takeshi Hiramatsu
- Department of Cardiovascular Surgery, Tokyo Women's Medical University Yachiyo Medical Center
| | | | | | - Hitoshi Yaku
- Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| |
Collapse
|