1
|
Iida N, Thoreson AR, Reisdorf RL, Tsukamoto I, El Hor H, Zhao C. Relationship Between the Changes of Tendon Elastic Moduli With Ultrasound Shear Wave Elastography and Mechanical Compression Test. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:586-591. [PMID: 38272742 DOI: 10.1016/j.ultrasmedbio.2024.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 12/07/2023] [Accepted: 01/01/2024] [Indexed: 01/27/2024]
Abstract
OBJECTIVE The purpose of this study was to investigate the consistency of the changes in the elastic modulus measured with ultrasound shear wave elastography (SWE) with changes measured through mechanical testing using tendons that were artificially altered by chemical modifications. METHODS Thirty-six canine flexor digitorum profundus tendons were used for this experiment. To mimic tendon mechanical property changes induced by tendinopathy conditions, tendons were treated with collagenase to soften the tissue by collagen digestion or with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) to stiffen the tissues through chemical crosslinking. Tendons were randomly assigned to one of three groups: immersion in phosphate-buffered saline (PBS) as a control group (n = 12), collagenase treatment (n = 12) or EDC treatment (n = 12). Immediately following SWE measurement of each tendon, mechanical compression testing was performed as a gold standard to validate the SWE measurement. Both tests were conducted before and after treatment. RESULTS The compressive modulus and SWE shear modulus significantly decreased after collagenase treatment. Conversely, both moduli significantly increased after EDC treatment. There was no significant difference in either modulus before or after PBS treatment. As a result of a regression analysis with the percentage change of the compressive modulus as the dependent variable and SWE shear modulus as the independent variable, the best-fit regression was found to be an exponential function and the coefficient of determination was 0.687. CONCLUSION The changes in the compressive moduli and SWE shear moduli in tendons induced by chemical treatments were correlated by approximately 70%.
Collapse
Affiliation(s)
- Naoya Iida
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Andrew R Thoreson
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA
| | | | - Ichiro Tsukamoto
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Hicham El Hor
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Chunfeng Zhao
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
2
|
Experimental characterisation of porcine subcutaneous adipose tissue under blunt impact up to irreversible deformation. Int J Legal Med 2021; 136:897-910. [PMID: 34862924 PMCID: PMC9005403 DOI: 10.1007/s00414-021-02755-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 11/26/2021] [Indexed: 12/04/2022]
Abstract
A deeper understanding of the mechanical characteristics of adipose tissue under large deformation is important for the analysis of blunt force trauma, as adipose tissue alters the stresses and strains that are transferred to subjacent tissues. Hence, results from drop tower tests of subcutaneous adipose tissue are presented (i) to characterise adipose tissue behaviour up to irreversible deformation, (ii) to relate this to the microstructural configuration, (iii) to quantify this deformation and (iv) to provide an analytical basis for computational modelling of adipose tissue under blunt impact. The drop tower experiments are performed exemplarily on porcine subcutaneous adipose tissue specimens for three different impact velocities and two impactor geometries. An approach based on photogrammetry is used to derive 3D representations of the deformation patterns directly after the impact. Median values for maximum impactor acceleration for tests with a flat cylindrical impactor geometry at impact velocities of 886 mm/s, 1253 mm/s and 2426 mm/s amount to 61.1 g, 121.6 g and 264.2 g, respectively, whereas thickness reduction of the specimens after impact amount to 16.7%, 30.5% and 39.3%, respectively. The according values for tests with a spherically shaped impactor at an impact velocity of 1253 mm/s are 184.2 g and 78.7%. Based on these results, it is hypothesised that, in the initial phase of a blunt impact, adipose tissue behaviour is mainly governed by the behaviour of the lipid inside the adipocytes, whereas for further loading, contribution of the extracellular collagen fibre network becomes more dominant.
Collapse
|
3
|
O'Brien C, Marr N, Thorpe C. Microdamage in the equine superficial digital flexor tendon. Equine Vet J 2021; 53:417-430. [PMID: 32772396 DOI: 10.1111/evj.13331] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 06/02/2020] [Accepted: 07/30/2020] [Indexed: 12/24/2022]
Abstract
The forelimb superficial digital flexor tendon (SDFT) is an energy-storing tendon that is highly susceptible to injury during activities such as galloping and jumping, such that it is one of the most commonly reported causes of lameness in the performance horse. This review outlines the biomechanical and biothermal effects of strain on the SDFT and how these contribute to the accumulation of microdamage. The effect of age-related alterations on strain response and subsequent injury risk is also considered. Given that tendon is a slowly healing and poorly regenerative tissue, prompt detection of early stages of pathology in vivo and timely adaptations to training protocols are likely to have a greater outcome than advances in treatment. Early screening tools and detection protocols could subsequently be of benefit in identifying subclinical signs of degeneration during the training programme. This provides an opportunity for preventative strategies to be implemented to minimise incidences of SDFT injury and reduce recovery periods in elite performance horses. Therefore, this review will focus on the modalities available to implement early screening and prevention protocols as opposed to methods to diagnose and treat injuries.
Collapse
Affiliation(s)
| | - Neil Marr
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| | - Chavaunne Thorpe
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| |
Collapse
|
4
|
Theodossiou SK, Pancheri NM, Martes AC, Bozeman AL, Brumley MR, Raveling AR, Courtright JM, Schiele NR. Neonatal Spinal Cord Transection Decreases Hindlimb Weight-Bearing and Affects Formation of Achilles and Tail Tendons. J Biomech Eng 2021; 143:1097185. [PMID: 33537729 DOI: 10.1115/1.4050031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Indexed: 01/08/2023]
Abstract
Mechanical loading may be required for proper tendon formation. However, it is not well understood how tendon formation is impacted by the development of weight-bearing locomotor activity in the neonate. This study assessed tendon mechanical properties, and concomitant changes in weight-bearing locomotion, in neonatal rats subjected to a low thoracic spinal cord transection or a sham surgery at postnatal day (P)1. On P10, spontaneous locomotion was evaluated in spinal cord transected and sham controls to determine impacts on weight-bearing hindlimb movement. The mechanical properties of P10 Achilles tendons (ATs), as representative energy-storing, weight-bearing tendons, and tail tendons (TTs), as representative positional, non-weight-bearing tendons were evaluated. Non- and partial weight-bearing hindlimb activity decreased in spinal cord transected rats compared to sham controls. No spinal cord transected rats showed full weight-bearing locomotion. ATs from spinal cord transected rats had increased elastic modulus, while cross-sectional area trended lower compared to sham rats. TTs from spinal cord transected rats had higher stiffness and cross-sectional area. Collagen structure of ATs and TTs did not appear impacted by surgery condition, and no significant differences were detected in the collagen crimp pattern. Our findings suggest that mechanical loading from weight-bearing locomotor activity during development regulates neonatal AT lateral expansion and maintains tendon compliance, and that TTs may be differentially regulated. The onset and gradual increase of weight-bearing movement in the neonate may provide the mechanical loading needed to direct functional postnatal tendon formation.
Collapse
Affiliation(s)
- Sophia K Theodossiou
- Biological Engineering, University of Idaho, 875 Perimeter Drive, MS 0904, Moscow, ID 83844
| | - Nicholas M Pancheri
- Biological Engineering, University of Idaho, 875 Perimeter Drive, MS 0904, Moscow, ID 83844
| | - Alleyna C Martes
- Psychology, Idaho State University, 921 South 8th Avenue Stop 8112, Pocatello, ID 83209
| | - Aimee L Bozeman
- Psychology, Idaho State University, 921 South 8th Avenue Stop 8112, Pocatello, ID 83209
| | - Michele R Brumley
- Psychology, Idaho State University, 921 South 8th Avenue Stop 8087, Pocatello, ID 83209
| | - Abigail R Raveling
- Biological Engineering, University of Idaho, 875 Perimeter Drive, MS 0904, Moscow, ID 83844
| | - Jeffrey M Courtright
- Biological Engineering, University of Idaho, 875 Perimeter Drive, MS 0904, Moscow, ID 83844
| | - Nathan R Schiele
- Biological Engineering, University of Idaho, 875 Perimeter Drive, MS 0904, Moscow, ID 83844
| |
Collapse
|
5
|
Bansal S, Peloquin JM, Keah NM, O'Reilly OC, Elliott DM, Mauck RL, Zgonis MH. Structure, function, and defect tolerance with maturation of the radial tie fiber network in the knee meniscus. J Orthop Res 2020; 38:2709-2720. [PMID: 32301519 PMCID: PMC7572531 DOI: 10.1002/jor.24697] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Revised: 04/03/2020] [Accepted: 04/11/2020] [Indexed: 02/04/2023]
Abstract
The knee menisci are comprised of two orthogonal collagenous networks-circumferential and radial-that combine to enable efficient load bearing by the tissue in adults. Here, we assessed how the structural and functional characteristics of these networks developed over the course of skeletal maturation and determined the role of these fiber networks in defect tolerance with tissue injury. Imaging of the radial tie fiber (RTF) collagen structure in medial bovine menisci from fetal, juvenile, and adult specimens showed increasing heterogeneity, anisotropy, thickness, and density with skeletal development. The mechanical analysis showed that the tensile modulus in the radial direction did not change with skeletal development, though the resilience (in the radial direction) increased and the tolerance to defects in the circumferential direction decreased, in adult compared to fetal tissues. This loss of defect tolerance correlated with increased order in the RTF network in adult tissue. These data provide new insights into the role of the radial fiber network in meniscus function, will lead to improved clinical decision-making in the presence of a tear and may improve engineering efforts to reproduce this critical load-bearing structure in the knee.
Collapse
Affiliation(s)
- Sonia Bansal
- Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania
- Translational Musculoskeletal Research Center, Corporal Michael J Crescenz Veterans Administration Medical Center, Philadelphia, Pennsylvania
| | - John M Peloquin
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - Niobra M Keah
- Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Translational Musculoskeletal Research Center, Corporal Michael J Crescenz Veterans Administration Medical Center, Philadelphia, Pennsylvania
| | - Olivia C O'Reilly
- Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Translational Musculoskeletal Research Center, Corporal Michael J Crescenz Veterans Administration Medical Center, Philadelphia, Pennsylvania
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - Robert L Mauck
- Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania
- Translational Musculoskeletal Research Center, Corporal Michael J Crescenz Veterans Administration Medical Center, Philadelphia, Pennsylvania
| | - Miltiadis H Zgonis
- Department of Orthopaedic Surgery, McKay Orthopaedic Research Laboratory, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Translational Musculoskeletal Research Center, Corporal Michael J Crescenz Veterans Administration Medical Center, Philadelphia, Pennsylvania
| |
Collapse
|
6
|
Gains CC, Correia JC, Baan GC, Noort W, Screen HRC, Maas H. Force Transmission Between the Gastrocnemius and Soleus Sub-Tendons of the Achilles Tendon in Rat. Front Bioeng Biotechnol 2020; 8:700. [PMID: 32766214 PMCID: PMC7379440 DOI: 10.3389/fbioe.2020.00700] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/04/2020] [Indexed: 01/19/2023] Open
Abstract
The Achilles tendon (AT) is comprised of three distinct sub-tendons bound together by the inter-subtendon matrix (ISTM). The interactions between sub-tendons will have important implications for AT function. The aim of this study was to investigate the extent to which the ISTM facilitates relative sliding between sub-tendons, and serves as a pathway for force transmission between the gastrocnemius (GAS) and soleus (SOL) sub-tendons of the rat AT. In this study, ATs were harvested from Wistar rats, and the mechanical behavior and composition of the ISTM were explored. To determine force transmission between sub-tendons, the proximal and distal ends of the GAS and SOL sub-tendons were secured, and the forces at each of these locations were measured during proximal loading of the GAS. To determine the ISTM mechanical behavior, only the proximal GAS and distal SOL were secured, and the ISTM was loaded in shear. Finally, for compositional analysis, histological examination assessed the distribution of matrix proteins throughout sub-tendons and the ISTM. The results revealed distinct differences between the forces at the proximal and distal ends of both sub-tendons when proximal loading was applied to the GAS, indicating force transmission between GAS and SOL sub-tendons. Inter-subtendon matrix tests demonstrated an extended initial low stiffness toe region to enable some sub-tendon sliding, coupled with high stiffness linear region such that force transmission between sub-tendons is ensured. Histological data demonstrate an enrichment of collagen III, elastin, lubricin and hyaluronic acid in the ISTM. We conclude that ISTM composition and mechanical behavior are specialized to allow some independent sub-tendon movement, whilst still ensuring capacity for force transmission between the sub-tendons of the AT.
Collapse
Affiliation(s)
- Connor C Gains
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, United Kingdom
| | - Janaina C Correia
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, Netherlands
| | - Guus C Baan
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, Netherlands
| | - Wendy Noort
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, Netherlands
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, United Kingdom
| | - Huub Maas
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, Netherlands
| |
Collapse
|
7
|
Martin JA, Kindig MW, Stender CJ, Ledoux WR, Thelen DG. Calibration of the shear wave speed-stress relationship in in situ Achilles tendons using cadaveric simulations of gait and isometric contraction. J Biomech 2020; 106:109799. [PMID: 32517985 DOI: 10.1016/j.jbiomech.2020.109799] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 04/10/2020] [Indexed: 11/26/2022]
Abstract
It has been shown that shear wave speed is directly dependent on axial stress in ex vivo tendons. Hence, a wave speed sensor could be used to track tendon loading during movement. However, adjacent soft tissues and varying joint postures may affect the wave speed-load relationship for intact tendons. The purpose of this study was to determine whether the proportional relationship between squared wave speed and stress holds for in situ cadaveric Achilles tendons, to evaluate whether this relationship is affected by joint angle, and to assess potential calibration techniques. Achilles tendon wave speed and loading were simultaneously measured during cadaveric simulations of gait and isometric contractions performed in a robotic gait simulator. Squared wave speed and axial stress were highly correlated during isometric contraction at all ankle postures (R2avg = 0.98) and during simulations of gait (R2avg = 0.92). Ankle plantarflexion angle did not have a consistent effect on the constant of proportionality (p = 0.217), but there was a significant specimen-angle interaction effect (p < 0.001). Wave speed-based predictions of tendon stress were most accurate (average RMS error = 11% of maximum stress) when calibrating to isometric contractions performed in a dorsiflexed posture that resembled the posture at peak Achilles loading during gait. The results presented here show that the linear relationship between tendon stress and squared shear wave speed holds for a case resembling in vivo conditions, and that calibration during an isometric task can yield accurate predictions of tendon loading during a functional task.
Collapse
Affiliation(s)
- Jack A Martin
- Department of Materials Science and Engineering , University of Wisconsin-Madison, United States; Department of Mechanical Engineering, University of Wisconsin-Madison, United States; Department of Orthopaedics and Rehabilitation, University of Wisconsin-Madison, United States.
| | - Matthew W Kindig
- RR&D Center for Limb Loss and MoBility, VA Puget Sound Health Care System, United States
| | - Christina J Stender
- RR&D Center for Limb Loss and MoBility, VA Puget Sound Health Care System, United States
| | - William R Ledoux
- RR&D Center for Limb Loss and MoBility, VA Puget Sound Health Care System, United States; Department of Mechanical Engineering, University of Washington, United States; Department of Orthopaedics and Sports Medicine, University of Washington, United States
| | - Darryl G Thelen
- Department of Materials Science and Engineering , University of Wisconsin-Madison, United States; Department of Mechanical Engineering, University of Wisconsin-Madison, United States; Department of Orthopaedics and Rehabilitation, University of Wisconsin-Madison, United States; Department of Biomedical Engineering, University of Wisconsin-Madison, United States
| |
Collapse
|
8
|
Onset of neonatal locomotor behavior and the mechanical development of Achilles and tail tendons. J Biomech 2019; 96:109354. [PMID: 31630773 DOI: 10.1016/j.jbiomech.2019.109354] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 08/21/2019] [Accepted: 09/18/2019] [Indexed: 12/27/2022]
Abstract
Tendon tissue engineering approaches are challenged by a limited understanding of the role mechanical loading plays in normal tendon development. We propose that the increased loading that developing postnatal tendons experience with the onset of locomotor behavior impacts tendon formation. The objective of this study was to assess the onset of spontaneous weight-bearing locomotion in postnatal day (P) 1, 5, and 10 rats, and characterize the relationship between locomotion and the mechanical development of weight-bearing and non-weight-bearing tendons. Movement was video recorded and scored to determine non-weight-bearing, partial weight-bearing, and full weight-bearing locomotor behavior at P1, P5, and P10. Achilles tendons, as weight-bearing tendons, and tail tendons, as non-weight-bearing tendons, were mechanically evaluated. We observed a significant increase in locomotor behavior in P10 rats, compared to P1 and P5. We also found corresponding significant differences in the maximum force, stiffness, displacement at maximum force, and cross-sectional area in Achilles tendons, as a function of postnatal age. However, the maximum stress, strain at maximum stress, and elastic modulus remained constant. Tail tendons of P10 rats had significantly higher maximum force, maximum stress, elastic modulus, and stiffness compared to P5. Our results suggest that the onset of locomotor behavior may be providing the mechanical cues regulating postnatal tendon growth, and their mechanical development may proceed differently in weight-bearing and non-weight-bearing tendons. Further analysis of how this loading affects developing tendons in vivo may inform future engineering approaches aiming to apply such mechanical cues to regulate engineered tendon formation in vitro.
Collapse
|
9
|
Bojsen-Møller J, Magnusson SP. Mechanical properties, physiological behavior, and function of aponeurosis and tendon. J Appl Physiol (1985) 2019; 126:1800-1807. [DOI: 10.1152/japplphysiol.00671.2018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
During human movement, the muscle and tendinous structures interact as a mechanical system in which forces are generated and transmitted to the bone and energy is stored and released to optimize function and economy of movement and/or to reduce risk of injury. The present review addresses certain aspects of how the anatomical design and mechanical and material properties of the force-transmitting tissues contribute to the function of the muscle-tendon unit and thus overall human function. The force-bearing tissues are examined from a structural macroscopic point of view down to the nanoscale level of the collagen fibril. In recent years, the understanding of in vivo mechanical function of the force-bearing tissues has increased, and it has become clear that these tissues adapt to loading and unloading and furthermore that force transmission mechanics is more complex than previously thought. Future investigations of the force-transmitting tissues in three dimensions will enable a greater understanding of the complex functional interplay between muscle and tendon, with relevance for performance, injury mechanisms, and rehabilitation strategies.
Collapse
Affiliation(s)
- Jens Bojsen-Møller
- Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark
- Section for Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - S. Peter Magnusson
- Institute of Sports Medicine, Department of Orthopaedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Department of Occupational and Physical Therapy, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
10
|
Choi R, Smith M, Clarke E, Little C. Cellular, matrix, and mechano-biological differences in load-bearing versus positional tendons throughout development and aging: a narrative review. Connect Tissue Res 2018; 59:483-494. [PMID: 30231648 DOI: 10.1080/03008207.2018.1504929] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE Summarise available evidence comparing the cellular, biochemical, structural and biomechanical properties, and the changes that occur in these parameters in response to stimuli, in differentially loaded tendons across different stages of life. METHODS The PubMed database was searched for literature pertaining to differences between tendons using the term "tendon" or "tendinopathy", plus one or more of the following descriptors: "loading", "positional", "weight- or load-bearing", and "energy-storing". The abstracts were reviewed and relevant full-length articles retrieved and used to assemble a narrative review. RESULTS The incidence and prevalence of tendon disorders ("tendinopathies") is increasing in Western societies, with limited evidence that currently available treatments have any significant long-term effect on the disease course. A key emerging hypothesis is that disease in different tendons and even different regions within a tendon may be distinct. The available literature indicates that there are phenotypic differences, not only in the constitutive compositional and material properties but also in resident cells of positional compared with load-bearing tendons. Evident during early tendon growth, such differences have become well established by adulthood. CONCLUSIONS The pheno-endotype of tendinopathy may be distinct between load-bearing tendons compared to positional tendons, which has translational implications with regard to preventing and managing tendinopathy. Better understanding of the molecular, cellular, and biomechanical pathophysiology underlying disease phenotypes, will allow more targeted/personalised treatment and therefore improve outcomes.
Collapse
Affiliation(s)
- Rachel Choi
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia.,b Murray Maxwell Biomechanics Laboratory, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Margaret Smith
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Elizabeth Clarke
- b Murray Maxwell Biomechanics Laboratory, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Christopher Little
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| |
Collapse
|
11
|
Fang F, Lake SP. Experimental evaluation of multiscale tendon mechanics. J Orthop Res 2017; 35:1353-1365. [PMID: 27878999 DOI: 10.1002/jor.23488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 11/16/2016] [Indexed: 02/04/2023]
Abstract
Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Orthopaedic Surgery, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| |
Collapse
|
12
|
Linderman SW, Kormpakis I, Gelberman RH, Birman V, Wegst UGK, Genin GM, Thomopoulos S. Shear lag sutures: Improved suture repair through the use of adhesives. Acta Biomater 2015; 23:229-239. [PMID: 26022966 PMCID: PMC4522236 DOI: 10.1016/j.actbio.2015.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 03/27/2015] [Accepted: 05/07/2015] [Indexed: 10/23/2022]
Abstract
Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model.
Collapse
Affiliation(s)
- Stephen W Linderman
- Department of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States; Department of Biomedical Engineering, Washington University, St Louis, MO 63130, United States
| | - Ioannis Kormpakis
- Department of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States
| | - Richard H Gelberman
- Department of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States
| | - Victor Birman
- Engineering Education Center, Missouri University of Science and Technology, St Louis, MO 63131, United States
| | - Ulrike G K Wegst
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States
| | - Guy M Genin
- Department of Mechanical Engineering and Materials Science, Washington University, St Louis, MO 63130, United States.
| | - Stavros Thomopoulos
- Department of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States; Department of Biomedical Engineering, Washington University, St Louis, MO 63130, United States; Department of Mechanical Engineering and Materials Science, Washington University, St Louis, MO 63130, United States.
| |
Collapse
|
13
|
Kondratko-Mittnacht J, Lakes R, Vanderby R. Shear loads induce cellular damage in tendon fascicles. J Biomech 2015; 48:3299-305. [PMID: 26162546 DOI: 10.1016/j.jbiomech.2015.06.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Revised: 05/26/2015] [Accepted: 06/17/2015] [Indexed: 11/17/2022]
Abstract
Tendon is vital to musculoskeletal function, transferring loads from muscle to bone for joint motion and stability. It is an anisotropic, highly organized, fibrous structure containing primarily type I collagen in addition to tenocytes and other extracellular matrix components contributing to maintenance and function. Tendon is generally loaded via normal stress in a longitudinal direction. However, certain situations, including fiber breakage, enzymatic remodeling, or tendon pathology may introduce various degrees of other loading modalities, such as shear-lag at the fiber level, potentially affecting cellular response and subsequent function. Fascicles from rat tail tendon were dissected and placed in one of three paired groups: intact, single laceration, or double laceration. Each pair had a mechanically tested and control specimen. Single laceration fascicles contained one transverse laceration to mimic a partial tear. Double laceration fascicles had overlapping, longitudinally separated lacerations on opposite sides to cause intra-fascicular shear transfer to be the primary mechanism of loading. Elastic properties of the fascicle, e.g. peak load, steady state load, and stiffness, decreased from intact to single laceration to double laceration groups. Surprisingly, 45% of the intact strength was maintained when shear was the primary internal load transfer mechanism. Cellular viability decreased after mechanical testing in both laceration groups; cell death appeared primarily in a longitudinal plane where high shear load transfer occurred. This cell death extended far from the injury site and may further compromise an already damaged tendon via enzymatic factors and subsequent remodeling associated with cell necrosis.
Collapse
Affiliation(s)
- Jaclyn Kondratko-Mittnacht
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, 53705 WI, USA
| | - Roderic Lakes
- Materials Science Program, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Engineering Physics, University of Wisconsin-Madison, Madison, 53705 WI, USA
| | - Ray Vanderby
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, 53705 WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, 53705 WI, USA; Materials Science Program, University of Wisconsin-Madison, Madison, 53705 WI, USA.
| |
Collapse
|