da Silva AMP, Horta Dos Santos FA, Mota RF, Teixeira MKS, Telles DM, Lourenço EJV. Clinical and radiographic outcomes of a two-piece ceramic implant: one year results from a prospective clinical trial. Clin Oral Investig 2024; 28:380. [PMID: 38886209 DOI: 10.1007/s00784-024-05783-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 06/11/2024] [Indexed: 06/20/2024]
Abstract
OBJECTIVE To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.
Collapse
Affiliation(s)
- Alexandre Marques Paes da Silva
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | | | - Rodrigo Franco Mota
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Mayla Kezy Silva Teixeira
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil.
| | - Daniel Moraes Telles
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Eduardo José Veras Lourenço
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| |
Collapse
|
2
|
Zieliński R, Lipa S, Piechaczek M, Sowiński J, Kołkowska A, Simka W. Finite Element Analysis and Fatigue Test of INTEGRA Dental Implant System. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1213. [PMID: 38473684 DOI: 10.3390/ma17051213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/25/2024] [Accepted: 02/29/2024] [Indexed: 03/14/2024]
Abstract
The study involved numerical FEA (finite element analysis) of dental implants. Based on this, fatigue tests were conducted according to the PN-EN 14801 standard required for the certification of dental products. Thanks to the research methodology developed by the authors, it was possible to conduct a thorough analysis of the impact of external and internal factors such as material, geometry, loading, and assembly of the dental system on the achieved value of fatigue strength limit in the examined object. For this purpose, FEM studies were based on identifying potential sites of fatigue crack initiation in reference to the results of the test conducted on a real model. The actions described in the study helped in the final evaluation of the dental system design process named by the manufacturer as INTEGRA OPTIMA 3.35. The objective of the research was to identify potential sites for fatigue crack initiation in a selected dental system built on the INTEGRA OPTIMA 3.35 set. The material used in the research was titanium grade 4. A map of reduced von Mises stresses was used to search for potential fatigue crack areas. The research [loading] was conducted on two mutually perpendicular planes positioned in such a way that the edge intersecting the planes coincided with the axis of the system. The research indicated that the connecting screw showed the least sensitivity (stress change) to the change in the loading plane, while the value of preload has a significant impact on the achieved fatigue strength of the system. In contrast, the endosteal implant (root) and the prosthetic connector showed the greatest sensitivity to the change in the loading plane. The method of mounting [securing] the endosteal implant using a holder, despite meeting the standards, may contribute to generating excessive stress concentration in the threaded part. Observation of the prosthetic connector in the Optima 3.35 system, cyclically loaded with a force of F ≈ 300 N in the area of the upper hexagonal peg, revealed a fatigue fracture. The observed change in stress peak in the dental connector for two different force application surfaces shows that the positioning of the dental system (setting of the socket in relation to the force action plane) is significantly decisive in estimating the limited fatigue strength.
Collapse
Affiliation(s)
- Rafał Zieliński
- Stomatologia na Ksiezym Mlynie, 16 D Tymienieckiego, 90-365 Lodz, Poland
| | - Sebastian Lipa
- Institute of Materials Science and Engineering, Lodz University of Technology, 90-924 Lodz, Poland
| | - Martyna Piechaczek
- Stomatologia na Ksiezym Mlynie, 16 D Tymienieckiego, 90-365 Lodz, Poland
| | - Jerzy Sowiński
- Private Dental Clinic, Tetmajera 3A Rd., 05-080 Izabelin C, Poland
| | - Agata Kołkowska
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
- Department of Inorganic Chemistry, Faculty of Chemistry, Analytical Chemistry and Electrochemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| | - Wojciech Simka
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| |
Collapse
|
3
|
Kohal RJ, Schikofski T, Adolfsson E, Vach K, Patzelt SBM, Nold J, Wemken G. Fracture Resistance of a Two-Piece Zirconia Implant System after Artificial Loading and/or Hydrothermal Aging-An In Vitro Investigation. J Funct Biomater 2023; 14:567. [PMID: 38132821 PMCID: PMC10743638 DOI: 10.3390/jfb14120567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/29/2023] [Accepted: 12/11/2023] [Indexed: 12/23/2023] Open
Abstract
The purpose of the present study was to assess the fracture resistance of a two-piece alumina-toughened zirconia implant system with a carbon-reinforced PEEK abutment screw. METHODS Thirty-two implants with screw-retained zirconia abutments were divided into four groups of eight samples each. Group 0 (control group) was neither loaded nor aged in a chewing simulator; group H was hydrothermally aged; group L was loaded with 98 N; and group HL was subjected to both hydrothermal aging and loading in a chewing simulator. One sample of each group was evaluated for t-m phase transformation, and the others were loaded until fracture. A one-way ANOVA was applied to evaluate differences between the groups. RESULTS No implant fracture occurred during the artificial chewing simulation. Furthermore, there were no statistically significant differences (p > 0.05) between the groups in terms of fracture resistance (group 0: 783 ± 43 N; group H: 742 ± 43 N; group L: 757 ± 86 N; group HL: 740 ± 43 N) and bending moment (group 0: 433 ± 26 Ncm; group H: 413 ± 23 Ncm; group L: 422 ± 49 Ncm; group HL: 408 ± 27 Ncm). CONCLUSIONS Within the limitations of the present investigation, it can be concluded that artificial loading and hydrothermal aging do not reduce the fracture resistance of the investigated implant system.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Tim Schikofski
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Erik Adolfsson
- RISE Research Institutes of Sweden, 431 53 Mölndal, Sweden;
| | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany;
| | - Sebastian Berthold Maximilian Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
- Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany
| | - Julian Nold
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| | - Gregor Wemken
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (T.S.); (J.N.); (G.W.)
| |
Collapse
|
4
|
Helal E, Gierthmuehlen PC, Bonfante EA, Campos TMB, Prott LS, Langner R, Spitznagel FA. Influence of straight versus angulated screw channel titanium bases on failure loads of two-piece ceramic and titanium implants restored with screw-retained monolithic crowns: An in-vitro study. Clin Oral Implants Res 2023; 34:1217-1229. [PMID: 37565379 DOI: 10.1111/clr.14157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 07/13/2023] [Accepted: 07/25/2023] [Indexed: 08/12/2023]
Abstract
OBJECTIVE To analyze the influence of titanium-base (straight [SSC]/angulated-screw-channel [ASC]) on failure-loads and bending-moments of two-piece ceramic and titanium-zirconium implants restored with monolithic-zirconia crowns after fatigue. MATERIALS AND METHODS Thirty-two anterior monolithic-screw-retained zirconia crowns were divided into four groups (n = 8/group) according to the factors: (1) type of implant material: two-piece titanium-zirconium implant (Ti-Zr; control-group) versus two-piece ceramic implant (CI; test-group) and (2) type of titanium-base: SSC (0° angle) versus ASC (25°). An intact implant was used for field emission gun-scanning electronic microscopy (FEG-SEM) characterization and Raman spectroscopy for phase analyses and residual stress quantification. All samples were exposed to fatigue with thermodynamic loading (1.2-million-cycles, 49 N, 1.6 Hz, 5-55°C) at a 30° angle. Surviving specimens were loaded until failure (SLF) and bending moments were recorded. Failed samples were examined using light microscope and SEM. Statistical analyses included ANOVA and Mann-Whitney U-test. RESULTS Raman-spectroscopy revealed the presence of residual compressive stresses. FEG-SEM revealed a roughened surface between threads and polished surface at the cervical-collar of the ceramic implant. All samples survived fatigue and were free of complications. Mean bending-moments (±SD) were: Ti-Zr-0: 241 ± 45 N cm, Ti-Zr-25: 303 ± 86 N cm, CI-0: 326 ± 58 N cm, CI-25: 434 ± 71 N cm. Titanium-base and implant-material had significant effects in favor of ASC titanium bases (p = .001) and ceramic-implants (p < .001). Failure analysis after SLF revealed severe fractures in ceramic implants, whereas titanium implants were restricted to plastic deformation. CONCLUSIONS Ceramic and titanium implants exhibited high reliability after fatigue, with no failures. From a mechanical perspective, titanium bases with ASC can be recommended for both ceramic and titanium implants and are safe for clinical application.
Collapse
Affiliation(s)
- E Helal
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - P C Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - E A Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - T M B Campos
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - L S Prott
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - R Langner
- Institute of Systems Neuroscience, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- Institute of Neuroscience and Medicine, Brain and Behavior (INM-7), Research Center Jülich, Jülich, Germany
| | - F A Spitznagel
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
5
|
Kohal RJ, Burkhardt F, Chevalier J, Patzelt SBM, Butz F. One-Piece Zirconia Oral Implants for Single Tooth Replacement: Five-Year Results from a Prospective Cohort Study. J Funct Biomater 2023; 14:jfb14020116. [PMID: 36826915 PMCID: PMC9964460 DOI: 10.3390/jfb14020116] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/06/2023] [Accepted: 02/15/2023] [Indexed: 02/22/2023] Open
Abstract
The intention of this 5-year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one-piece zirconia implant system for single tooth replacement. Sixty-five patients received a total of 66 single-tooth implants. All implants immediately received temporary restorations and were finally restored with all-ceramic crowns. Follow-ups were performed at the prosthetic delivery, after 1, 3, and 5 years. Peri-implant and dental soft-tissue parameters were evaluated and patient-reported outcomes recorded. To monitor peri-implant bone remodelling, standardised radiographs were taken at the implant insertion and at the 1-, 3-, and 5-year follow-ups. In the course of 5 years, 14 implants were lost, resulting in a cumulative implant survival rate of 78.2%. The mean marginal bone loss from the implant insertion to the 5-year follow-up amounted to 1.12 mm. Probing depth, clinical attachment level, bleeding, and plaque index increased over time. In 91.5% of the implants, the papilla index showed levels of 1 or 2, respectively. At the end of the study, the patient satisfaction was higher compared to the pre-treatment measurements. Due to the low survival rate after five years and the noticeably high frequency of advanced bone loss observed in this study, the implant has not met the launch criteria, as it would have not been recommended for routine clinical use.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Jerome Chevalier
- INSA-Lyon, MATEIS Laboratory, University of Lyon, UMR CNRS 5510, 20 Avenue Albert Einstein, CEDEX, 69621 Villeurbanne, France
| | - Sebastian Berthold Maximilian Patzelt
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Frank Butz
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Belchenstrasse 6a, 79189 Bad Krozingen, Germany
- Correspondence:
| |
Collapse
|
6
|
Kohal RJ, von Schierholz C, Nold J, Spies BC, Adolfsson E, Vach K, Burkhardt F. Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment. Clin Oral Implants Res 2023; 34:105-115. [PMID: 36444693 DOI: 10.1111/clr.14022] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/31/2022] [Accepted: 11/22/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging. METHODS Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 107 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT). One group remained untreated (group 0). A sample from each group was cross-sectioned and examined by scanning electron microscopy for possible crystal phase transformation. The remaining samples were then loaded to fracture in a static loading test. A one-way ANOVA was used for statistical analyses. RESULTS During dynamic loading, three implants of group DL and six implants of group DL/HT fractured at a load of 98 N. The fracture strength of group DL/HT (108 ± 141 Ncm) was significantly reduced compared to the other groups (group 0: 342 ± 36 Ncm; HT: 363 ± 49 Ncm; DL: 264 ± 198 Ncm) (p < .05). Fractures from group 0 and HT occurred at both implant and abutment level, whereas implants from group DL and DL/HT fractured only at implant level. A shallow monoclinic transformation zone of approximately 2 μm was observed following hydrothermal treatment. CONCLUSIONS Within the limitations of this study, it can be concluded that dynamic loading and the combination of loading and aging reduced the fracture strength of the implant abutment combination. Hydrothermal treatment caused a shallow transformation zone which had no influence on the fracture strength.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Christopher von Schierholz
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Julian Nold
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | | | - Kirstin Vach
- Faculty of Medicine, Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, University of Freiburg, Freiburg, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
7
|
Zhang F, Monzavi M, Li M, Čokić S, Manesh A, Nowzari H, Vleugels J, Van Meerbeek B. Fracture analysis of one/two-piece clinically failed zirconia dental implants. Dent Mater 2022; 38:1633-1647. [PMID: 36064469 DOI: 10.1016/j.dental.2022.08.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/13/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Analyzing factors that may have led to fracture of zirconia implants by macro/micro-fractography. METHODS Six one-piece and ten two-piece full-ceramic zirconia implants from two manufacturers, Z-Systems and CeraRoot, were retrieved after clinical failure. The time-to-failure ranged from 3 to 49 months. Optical and scanning electron microscopy (SEM) were used to analyze the fracture planes at the macro- and microscopic level. Treatment planning, surgical protocol, fracture-origin location and characteristic fracture features were assessed. RESULTS The fracture of all implants seemed to have been primarily due to overload in bending mode, while the fracture-initiation sites varied for the one- and two-piece implants. The fracture of all one-piece implants originated in the constriction region between two threads in the endosseous implant part. For two-piece implants, the abutment neck, internal abutment-implant connections and inner threads were found to be the main fracture-initiation sites. Surface defects at the root area for one-piece implants and damages at the abutment surface for two-piece implants were connected to the fracture origins. Importantly, the clinical failures of implants were often found to result from combined effects related to patient aspects, treatment planning/protocols, a high bending moment at the weakest link, implant-surface conditions and specific implant designs. SIGNIFICANCE This study provided information to be considered for future optimization of treatment planning and the surgical protocol for zirconia implants. Optimization of the surface conditions and the zirconia-starting powder were also suggested.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`; KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium.
| | - Mona Monzavi
- Periodontics and Ceramic Implantology (private Practice), 1401N Tustin Ave Suite #345, Santa Ana, CA 92705, USA
| | - Maoyin Li
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Stevan Čokić
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| | - Al Manesh
- Mission Dental Implant Center (private Practice), 26800 Crown Valley Pkwy Ste 425, Mission Viejo, CA 92691, USA
| | - Hessam Nowzari
- Periodontics and Implant Dentistry (private practice), 120 S Spalding Dr #201, Beverlyhills, CA 90210, USA
| | - Jef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| |
Collapse
|
8
|
Bending moment of implants restored with CAD/CAM polymer-based restoration materials with or without a titanium base before and after artificial aging. Dent Mater 2022; 38:e245-e255. [PMID: 35715247 DOI: 10.1016/j.dental.2022.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 05/05/2022] [Accepted: 06/05/2022] [Indexed: 11/22/2022]
Abstract
OBJECTIVES To test and compare two types of implant systems restored with four monolithic polymer-based materials with regard to their bending moments (BM) before and after aging. METHODS A total of 192 tissue-level implants (TRI Dental Implants) differing in the presence (TiB, Octa line, n = 96) or absence (NTiB, Matrix line, n = 96) of a titanium base were restored with mandibular right first molar crowns manufactured from composite (CC), polymer-infiltrated ceramic (VE), PMMA (PM) and a 3D printed resin (ND) (n = 24). Half of the specimens (n = 12) were loaded for 1,200,000 cycles (50 N, 1.3 Hz, TC: 5/55 °C, 6000×) and examined for failures. Fracture load was measured according to ISO standard 14801, BM was calculated, and fracture types were examined. Data were analyzed using parametric statistics (p < 0.05). RESULTS No failures were observed after 600,000 cycles. After 1,200,000 cycles, wear traces were recorded in all groups except PM, VE and CC on TiB implants. In group CC on NTiB implants, three specimens were rated zero in BM testing as they showed fracture of the screw. Regarding BM, TiB implants exhibited higher values than NTiB implants with aged CC (p = 0.023), aged PM (p < 0.001), initial PM (p = 0.011) and initial VE (p < 0.001). No differences occurred among the implant types with initial CC, initial ND, aged ND and aged VE. With regard to initial BM values, NTiB implants showed higher values for ND and CC compared with PM and VE (p < 0.001). No differences in initial BM values were found for the tested materials on TiB implants (p > 0.116). When aged, restoration material had no impact on the BM values of NTiB implants (p ≥ 0.233). Aged TiB implants showed higher values in combination with CC than with ND (p = 0.001). PM and VE showed similar values as ND and CC. Artificial aging led to a decrease of BM within PM, CC and ND on NTiB implants and ND on TiB implants. The majority of failures after testing were characterized by crown fractures in two to four pieces. Fractures in more pieces with smaller fragments occurred primarily for ND. SIGNIFICANCE The use of NTiB implants with the polymer-based materials tested can only be recommended for clinical use as interim prostheses. CC seems to show a positive effect on the BM. Clinical research investigating the in vivo behavior is necessary to confirm these findings.
Collapse
|
9
|
Spitznagel FA, Balmer M, Wiedemeier DB, Jung RE, Gierthmuehlen PC. Clinical outcomes of all-ceramic single crowns and fixed dental prostheses supported by ceramic implants: A systematic review and meta-analyses. Clin Oral Implants Res 2021; 33:1-20. [PMID: 34665900 PMCID: PMC9297865 DOI: 10.1111/clr.13871] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 06/17/2021] [Accepted: 09/28/2021] [Indexed: 02/07/2023]
Abstract
Objective To analyze the clinical outcomes of all‐ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. Materials and Methods Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all‐ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient‐related outcome measurements. Meta‐analyses were performed after 1, 2, and 5 years using random‐effect meta‐analyses. Results Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement‐retained reconstructions (mean observation: 12.0–61.0 months). Meta‐analyses estimated a 5‐year survival rate of 94% (95% confidence interval [CI]: 82%–100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%–100%); veneered zirconia SCs, 89% (95%CI: 62%–100%); and veneered zirconia FDPs 94% (95%CI: 81%–100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%–11%); veneered zirconia SCs, 38% (95%CI: 24%–54%); and veneered zirconia FDPs, 57% (95%CI: 38%–76%). Further outcomes were summarized descriptively. Conclusions Due to the limited data available, only tendencies could be identified. All‐ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid‐term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.
Collapse
Affiliation(s)
- Frank Akito Spitznagel
- Department of Prosthodontics, School of Dentistry, Heinrich-Heine-University, Düsseldorf, Germany
| | - Marc Balmer
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Daniel B Wiedemeier
- Statistical Services, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Ronald Ernst Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | | |
Collapse
|
10
|
李 文, 丁 茜, 原 福, 孙 丰, 郑 剑, 鲍 蕊, 张 磊. [Effects of femtosecond laser treatment on surface characteristics and flexural strength of zirconia]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2021; 53:770-775. [PMID: 34393243 PMCID: PMC8365050 DOI: 10.19723/j.issn.1671-167x.2021.04.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Indexed: 06/13/2023]
Abstract
OBJECTIVE To evaluate the effects of femtosecond laser treated microgrooved surface on microscopic topography, phase transformation, and three-points flexural strength of zirconia, and to provide reference for surface microstructure optimization of zirconia implant. METHODS According to different surface treatment methods, 57 computer aided design/computer aided manufacture (CAD/CAM) zirconia bars (20.0 mm×4.0 mm×1.4 mm) were evenly divided into three groups: sintered group, no treatment after sintering, taken as control; sandblasted group, sandblasted with 110 μm aluminium oxide (Al2O3) after sintering; microgrooved group, femtosecond laser fabricated microgrooves with 50 μm width, 30 μm depth, and 100 μm pitch. Surface microscopic topography was observed with scanning electron microscope (SEM) and 3D laser microscope. Further, surface roughness in each group and microgroove size were measured. Crystal phase was analyzed with X-ray diffraction. Specimens were subjected to three- points flexural strength test, and Weibull distribution was used to analyze their strength characteristics. RESULTS SEM showed that sintered surface was flat with clear grain structure; sandblasted surface exihibited bumps and holes with sharp margins and irregular shape; microgrooves were regularly aligned without evident defect, and nano-scale particles were observed on the surface inside of the microgrooves. Ra value of microgrooved group [(9.42±0.28)] μm was significantly higher than that of sandblasted group [(1.04±0.03) μm] and sintered group [(0.60±0.04) μm], and there was statistical difference between sandblasted group and sintered group (P < 0.001). The microgroove size was precise with (49.75±1.24) μm width, (30.85±1.02) μm depth, and (100.58±1.94) μm pitch. Crystal phase analysis showed that monoclinic volume fraction of sandblasted group (18.17%) was much higher than that of sintered group (1.55%), while microgrooved group (2.21%) was similar with sintered group. The flexural strength of sandblasted group (986.22±163.25) MPa had no statistical difference with that of sintered group (946.46±134.15) MPa (P=0.847), but the strength in microgrooved group (547.92±30.89) MPa dropped significantly compared with the other two groups (P < 0.001). Weibull modulus of sintered, sandblasted, microgrooved groups were 7.89, 6.98, and 23.46, respectively. CONCLUSION Femtosecond laser was able to form micro/nanostructured microgrooves on zirconia surface, which deleteriously affected the flexural strength of zirconia.
Collapse
Affiliation(s)
- 文锦 李
- 北京大学口腔医学院·口腔医院,修复科 国家口腔医学中心 国家口腔疾病临床医学研究中心 口腔数字化医疗技术和材料国家工程实验室,北京 100081Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
| | - 茜 丁
- 北京大学口腔医学院·口腔医院,修复科 国家口腔医学中心 国家口腔疾病临床医学研究中心 口腔数字化医疗技术和材料国家工程实验室,北京 100081Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
| | - 福松 原
- 北京大学口腔医学院·口腔医院,口腔医学数字化研究中心 口腔数字医学北京市重点实验室 国家卫生健康委口腔医学计算机应用工程技术研究中心,北京 100081Center for Digital Dentistry, Peking University School and Hospital of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, Beijing 100081, China
| | - 丰博 孙
- 清华大学材料学院,北京 100084School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - 剑桥 郑
- 北京大学口腔医学院·口腔医院,口腔医学数字化研究中心 口腔数字医学北京市重点实验室 国家卫生健康委口腔医学计算机应用工程技术研究中心,北京 100081Center for Digital Dentistry, Peking University School and Hospital of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, Beijing 100081, China
| | - 蕊 鲍
- 北京航空航天大学航空科学与工程学院,北京 100191School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
| | - 磊 张
- 北京大学口腔医学院·口腔医院,修复科 国家口腔医学中心 国家口腔疾病临床医学研究中心 口腔数字化医疗技术和材料国家工程实验室,北京 100081Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
| |
Collapse
|
11
|
Burkhardt F, Spies BC, Riemer L, Adolfsson E, Doerken S, Kohal RJ. Fracture resistance and crystal phase transformation of a one- and a two-piece zirconia implant with and without simultaneous loading and aging-An in vitro study. Clin Oral Implants Res 2021; 32:1288-1298. [PMID: 34352139 DOI: 10.1111/clr.13825] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Lennart Riemer
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | | | - Sam Doerken
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
12
|
Microstructure and Young’s modulus evolution during re-sintering of partially sintered alumina-zirconia composites (ATZ ceramics). Ann Ital Chir 2021. [DOI: 10.1016/j.jeurceramsoc.2021.01.045] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
13
|
Burkhardt F, Harlass M, Adolfsson E, Vach K, Spies BC, Kohal RJ. A Novel Zirconia-Based Composite Presents an Aging Resistant Material for Narrow-Diameter Ceramic Implants. MATERIALS 2021; 14:ma14092151. [PMID: 33922688 PMCID: PMC8122934 DOI: 10.3390/ma14092151] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 04/19/2021] [Accepted: 04/21/2021] [Indexed: 01/23/2023]
Abstract
A novel ceria-stabilized zirconia-alumina-aluminate composite (Ce-TZP-comp) that is not prone to aging presents a potential alternative to yttrium-stabilized zirconia for ceramic oral implants. The objective of this study was to evaluate the long-term stability of a one-piece narrow-diameter implant made of Ce-TZP-comp. Implant prototypes with a narrow (3.4 mm) and regular (4.0 mm) diameter were embedded according to ISO 14801, and subgroups (n = 8) were subsequently exposed to dynamic loading (107 cycles, 98N) and/or hydrothermal treatment (aging, 85 °C). Loading/aging was only applied as a combined protocol for the 4.0 mm diameter implants. One subgroup of each diameter remained untreated. One sample was cross-sectioned from each subgroup and evaluated with a scanning electron microscope for phase-transformation of the lattice. Finally, the remaining samples were loaded to fracture. A multivariate linear regression model was applied for statistical analyses (significance at p < 0.05). All samples withstood the different loading/aging protocols and no transformation propagation was observed. The narrow diameter implants showed the lowest fracture load after combined loading/aging (628 ± 56 N; p < 0.01), whereas all other subgroups exhibited no significantly reduced fracture resistance (between 762 ± 62 and 806 ± 73 N; p > 0.05). Therefore, fracture load values of Ce-TZP-comp implants suggest a reliable intraoral clinical application in the anterior jaw regions.
Collapse
Affiliation(s)
- Felix Burkhardt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Markus Harlass
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | | | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
- Correspondence:
| |
Collapse
|
14
|
Optimized Planning and Evaluation of Dental Implant Fatigue Testing: A Specific Software Application. BIOLOGY 2020; 9:biology9110372. [PMID: 33142807 PMCID: PMC7693306 DOI: 10.3390/biology9110372] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 10/29/2020] [Accepted: 10/30/2020] [Indexed: 11/17/2022]
Abstract
Mechanical complications in implant-supported fixed dental prostheses are often related to implant and prosthetic design. Although the current ISO 14801 provides a framework for the evaluation of dental implant mechanical reliability, strict adherence to it may be difficult to achieve due to the large number of test specimens which it requires as well as the fact that it does not offer any probabilistic reference for determining the endurance limit. In order to address these issues, a new software program called ProFatigue is presented as a potentially powerful tool to optimize fatigue testing of implant-supported prostheses. The present work provides a brief description of some concepts such as load, fatigue and stress-number of cycles to failure curves (S-N curves), before subsequently describing the current regulatory situation. After analyzing the two most recent versions of the ISO recommendation (from 2008 and 2016), some limitations inherent to the experimental methods which they propose are highlighted. Finally, the main advantages and instructions for the correct implementation of the ProFatigue free software are given. This software will contribute to improving the performance of fatigue testing in a more accurate and optimized way, helping researchers to gain a better understanding of the behavior of dental implants in this type of mechanical test.
Collapse
|
15
|
Reliability of an injection-moulded two-piece zirconia implant with PEKK abutment after long-term thermo-mechanical loading. J Mech Behav Biomed Mater 2020; 110:103967. [PMID: 32851978 DOI: 10.1016/j.jmbbm.2020.103967] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/29/2020] [Accepted: 07/01/2020] [Indexed: 01/18/2023]
Abstract
Zirconia implants are appreciated in some clinical indications in light of their aesthetic appearance and good biocompatibility. The aim of this work was to evaluate the performance of a newly developed two-piece zirconia/polyether ketone ketone (PEKK) implant-abutment combination after long-term cyclic loading in a hydrothermal environment, using a new protocol adapted from two available ISO standards. Sixteen implants (n = 8/group) were embedded according to ISO 14801 and divided into two groups: implants in the Observational Group (OG) were cyclically loaded for 60 days (98 N, 10 million loading cycles, 2 Hz) in 85 °C water in a chewing simulator, while non-loaded/non-aged implants (as-received) constituted the Control Group (CG). After 4.7 million loading cycles, one OG implant fractured in the chewing simulator. The surviving implants were compared to CG implants by X-ray diffraction (XRD) to investigate potential ageing as suggested by ISO 13356, but also μ-Raman spectroscopy, Focused-Ion-Beam - Scanning-Electron-Microscopy (FIB-SEM), and load-to-fracture. Ageing was shown to have limited influence on the evaluated zirconia implant, with increased monoclinic content after loading/ageing being to a shallow transformed zone of ~2 μm at the implant surface. However, OG implants showed a significantly decreased fracture load of 751 ± 231 N (CG: 995 ± 161 N; p = .046). These values enable clinical application, but the fact that one failure was recorded during cyclic fatigue along with the significant decrease in strength after cyclic loading/ageing suggest that there may be room for further optimization of especially the PEKK abutment. Furthermore, good agreement was observed between the fracture modes of the implant that failed during the cyclic fatigue experiment and the in vivo failure of one implant during pre-clinical trials, validating the interest of the in vitro protocol used in this work to check the reliability of zirconia implant.
Collapse
|
16
|
Kim JH, Kim MY, Knowles JC, Choi S, Kang H, Park SH, Park SM, Kim HW, Park JT, Lee JH, Lee HH. Mechanophysical and biological properties of a 3D-printed titanium alloy for dental applications. Dent Mater 2020; 36:945-958. [DOI: 10.1016/j.dental.2020.04.027] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 04/20/2020] [Accepted: 04/30/2020] [Indexed: 12/22/2022]
|
17
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|
18
|
Monzavi M, Zhang F, Meille S, Douillard T, Adrien J, Noumbissi S, Nowzari H, Chevalier J. Influence of artificial aging on mechanical properties of commercially and non-commercially available zirconia dental implants. J Mech Behav Biomed Mater 2019; 101:103423. [PMID: 31536885 DOI: 10.1016/j.jmbbm.2019.103423] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 09/04/2019] [Accepted: 09/07/2019] [Indexed: 02/04/2023]
Abstract
OBJECTIVE To evaluate the effect of artificial aging on the mechanical resistance and micromechanical properties of commercially and noncommercially available zirconia dental implants. METHODS Scanning electron microscopy (SEM) and X-ray computed tomography (X-CT) were performed on implant systems including: Z-systems®, Straumann®, Zibone® and commercially and non-commercially available TAV dental® with varying grain sizes. Accelerated aging was performed at 134 °C and 2-bar pressure for 30 hours. Before and after aging, the mechanical load to failure was investigated and the bending moments were calculated. Nanoindentation responses of the representative Zibone implant before and after aging were performed to evaluate the effects of aging on hardness (H) and Young's modulus (E). A two-sample t-test statistical analysis was used to determine significant differences of bending moments within groups. RESULTS All implants presented with compact and homogenous core structures without porosities. The bending moment was significantly increased after aging for all groups (P ≤ 0.05) except for Z-systems (significant decrease (P = 0.022)) and TAV group 3 (no significant increase (P = 0.181)). The increase in bending moment was less pronounced with increasing grain size in TAV groups (group 1: P = 0.036, group 2: P = 0.05, group 3: P = 0.18). E and H were reduced approximately 32% and 18% respectively following aging within the transformed, microcracked zone of the presentative Zibone implant. CONCLUSIONS Aging led to both increase and decrease of the mechanical properties of the implant systems analyzed. The apparent contrast amongst groups can be explained based on differences in grain sizes and surface features. Aging decreased micromechanical properties of one implant system which warrants further investigation.
Collapse
Affiliation(s)
- Mona Monzavi
- Private Practice, 120 S Spalding Drive, Beverly Hills, CA, 90212, USA; Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France.
| | - Fei Zhang
- Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France
| | - Sylvain Meille
- Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France
| | - Thierry Douillard
- Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France
| | - Jérôme Adrien
- Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France
| | - Sammy Noumbissi
- International Academy of Ceramic Implantology Zirconia Implant Research Group-ZIRG, 801 Wayne Avenue, Suite G200, Silver Spring, MD, 20910, USA
| | - Hessam Nowzari
- Private Practice, 120 S Spalding Drive, Beverly Hills, CA, 90212, USA
| | - Jérôme Chevalier
- Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 7 Avenue Jean Capelle, 69621, Villeurbanne Cedex, France
| |
Collapse
|
19
|
Stimmelmayr M, Lang A, Beuer F, Mansour S, Erdelt K, Krennmair G, Güth JF. Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants-an in vitro study. Clin Oral Investig 2019; 24:1801-1806. [PMID: 31478098 DOI: 10.1007/s00784-019-03043-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 08/05/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES To measure the abutment rotation and fracture load of two-piece zirconia implants screwed with three different abutment screw materials. MATERIAL AND METHODS Thirty-six zirconia implants with 36 zirconia abutments were distributed into 3 test groups: group G connected with gold screws, group T with titanium screws, and group P with peek screws. In the first part of the study, the rotation angle of the abutments was measured. The second part of the study measured the maximum fracture force of adhesively bonded lithium disilicate crowns after artificial aging and fracture modes were reported. RESULTS In group G, the median rotation angle was 8.0°, in group T 11.6°, and in group P 9.5°. After artificial aging, no screw loosening, crown, abutment, or implant fracture occurred. The median fracture force in group G was 250 N, in group T 263 N, and in group P 196 N. CONCLUSIONS Rotation angles and fracture loads of two-piece zirconia implants with gold, titanium, or peek screws showed no significant differences; however, fracture loads showed inferior results for group P. CLINICAL RELEVANCE The indication for the material peek as an abutment screw is still questionable and should be considered carefully.
Collapse
Affiliation(s)
- Michael Stimmelmayr
- Private Practice for Oral Surgery, 93413, Cham, Germany. .,Department of Prosthodontics, University of Munich, Goethestr 70, 80336, Munich, Germany.
| | - Anna Lang
- Department of Prosthodontics, University of Munich, Goethestr 70, 80336, Munich, Germany
| | - Florian Beuer
- Department of Prosthodontics and Gerontostomtology, University of Berlin, Assmannshauser Strasse 4-6, 14197, Berlin, Germany
| | - Sonia Mansour
- Department of Prosthodontics and Gerontostomtology, University of Berlin, Assmannshauser Strasse 4-6, 14197, Berlin, Germany
| | - Kurt Erdelt
- Department of Prosthodontics, University of Munich, Goethestr 70, 80336, Munich, Germany
| | - Gerald Krennmair
- Dental School, University of Vienna, Sensengasse 2a, 1090, Vienna, Austria
| | - Jan-Frederik Güth
- Department of Prosthodontics, University of Munich, Goethestr 70, 80336, Munich, Germany
| |
Collapse
|
20
|
Agustín-Panadero R, Serra-Pastor B, Roig-Vanaclocha A, Fons-Font A, Solá-Ruiz MF. Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants. PLoS One 2019; 14:e0220551. [PMID: 31393888 PMCID: PMC6687178 DOI: 10.1371/journal.pone.0220551] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 07/18/2019] [Indexed: 11/19/2022] Open
Abstract
The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic loading and thermocycling), followed by static loading to evaluate mechanical fracture resistance, and the mode of failure produced. Mean fracture resistance values were: Control Group T-MC, 575.85±120.01 N; Group Z-Z 459.64±66.52 N; Group Z-LD, 531.77±34.10 N; and Group Z-NCR, 587.05±59.27 N. In Group T-MC, fracture occurred in the prosthetic fixing screw in 100% of specimens. In Group Z-Z, 80% of fractures occurred in the fixing screw, 15% in the abutment, and 5% in the abutment and crown. In Group Z-LD, 60% of fractures were produced in the fixing screw and 40% in the abutment. In Group Z-NCR, 70% of fractures were produced in the fixing screw and 30% in the abutment. All the abutments and crowns analyzed have the potential to withstand the physiological occlusal forces to which they would be subject in the anterior region. Lithium disilicate and nano-ceramic resin crowns cemented onto zirconia abutments are a good restoration alternative for single implants in the anterior sector.
Collapse
Affiliation(s)
- Rubén Agustín-Panadero
- Department of Dental Medicine, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - Blanca Serra-Pastor
- Department of Dental Medicine, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - Ana Roig-Vanaclocha
- Department of Dental Medicine, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - Antonio Fons-Font
- Department of Dental Medicine, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - María Fernanda Solá-Ruiz
- Department of Dental Medicine, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
- * E-mail:
| |
Collapse
|
21
|
Current status of zirconia implants in dentistry: preclinical tests. J Prosthodont Res 2018; 63:1-14. [PMID: 30205949 DOI: 10.1016/j.jpor.2018.07.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 07/18/2018] [Accepted: 07/26/2018] [Indexed: 11/23/2022]
Abstract
PURPOSE This systematic review aimed to provide an overview of zirconia implants as well as regarding the outcome of the implant-restorative complex in preclinical studies. STUDY SELECTION An electronic search of the literature prior to July 2017 was performed to identify all articles related to preclinical research on zirconia implants. The search was conducted using MEDLINE (National Library of Medicine) and PubMed without restrictions concerning the date of publication. The search terminology included: zirconia implant, osseointegration, bone-to-implant contact, soft tissue, histology, histomorphometry, surface modification, surface roughness, surface characteristics, and restoration (connecting multiple keywords with AND, OR). RESULTS Fifty-seven studies were finally selected from an initial yield of 654 titles, and the data were extracted. The identified preclinical studies focused on several aspects related to zirconia implants, namely biocompatibility, mechanical properties, implant design, osseointegration capacity, soft tissue response, and restorative options. Due to heterogeneity of the studies, a meta-analysis was not possible. The most frequently used zirconia material for the fabrication of implants is yttria-stabilized tetragonal zirconia polycrystal. The resistance-to-fracture for zirconia implants ranged between 516-2044N. The mostly investigated parameter was osseointegration, which is compared to that of titanium. A lack of evidence was found with other parameters. CONCLUSIONS Due to its good biocompatibility as well as favorable physical and mechanical properties, zirconia implants are a potential alternative to titanium implants. However, knowledge regarding the implant-restorative complex and related aspects is still immature to recommend its application for daily practice.
Collapse
|
22
|
Spies BC, Fross A, Adolfsson E, Bagegni A, Doerken S, Kohal RJ. Stability and aging resistance of a zirconia oral implant using a carbon fiber-reinforced screw for implant-abutment connection. Dent Mater 2018; 34:1585-1595. [PMID: 30180975 DOI: 10.1016/j.dental.2018.08.290] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/16/2018] [Accepted: 08/18/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the long-term stability of a metal-free zirconia two-piece implant assembled with a carbon fiber-reinforced (CRF) screw by means of transformation propagation, potential changes in surface roughness, the gap size of the implant-abutment connection, and fracture load values. METHODS In a combined procedure, two-piece implants made from alumina-toughened zirconia were dynamically loaded (107 cycles) and hydrothermally aged (85°, 60days). Implants made from titanium (Ti) and a titanium-zirconium (TiZr) alloy with a titanium abutment screw served as control. Transformation propagation (ATZ) and gap size of the IAC were monitored at cross-sections by scanning electron microscopy (SEM). Furthermore, changes in surface roughness of ATZ implants were measured. Finally, implants were statically loaded to fracture. Linear regression models and pairwise comparisons were used for statistical analyses. RESULTS Independent of the implant bulk material, dynamic loading/hydrothermal aging did not decrease fracture resistance (p=0.704). All test and control implants fractured at mean loads >1100N. Gap size of the IAC remained stable (<5μm) or decreased. None of the CFR screws fractured during static or dynamic loading. Monoclinic layer thickness of ATZ implants increased by 2-3μm at surfaces exposed to water, including internal surfaces of the IAC. No changes in surface roughness were observed. SIGNIFICANCE Combined hydrothermal aging and dynamic loading did not affect the above-mentioned parameters of the evaluated two-piece ATZ implant. Mean fracture loads >1100N suggest a reliable clinical application.
Collapse
Affiliation(s)
- Benedikt C Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, Berlin, Germany.
| | - Alexander Fross
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | | | - Aimen Bagegni
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sam Doerken
- Medical Center - University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany
| | - Ralf-Joachim Kohal
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| |
Collapse
|
23
|
Evaluation of Fatigue Behavior in Dental Implants from In Vitro Clinical Tests: A Systematic Review. METALS 2018. [DOI: 10.3390/met8050313] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
24
|
Ultimate force and stiffness of 2-piece zirconium dioxide implants with screw-retained monolithic lithium-disilicate reconstructions. J Prosthodont Res 2018; 62:258-263. [DOI: 10.1016/j.jpor.2017.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Revised: 09/01/2017] [Accepted: 11/13/2017] [Indexed: 11/21/2022]
|
25
|
Janner SFM, Gahlert M, Bosshardt DD, Roehling S, Milz S, Higginbottom F, Buser D, Cochran DL. Bone response to functionally loaded, two-piece zirconia implants: A preclinical histometric study. Clin Oral Implants Res 2017; 29:277-289. [PMID: 29288505 DOI: 10.1111/clr.13112] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/16/2017] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To evaluate the bone response to a two-piece zirconia implant in comparison with a control titanium implant in the canine mandible 4 and 16 weeks after restoration. MATERIAL AND METHODS Zirconia and titanium implants were alternately placed bilaterally in healed mandibular molar and premolar sites of five canines. Full-ceramic single-tooth restorations were cemented after 6 weeks of transmucosal healing, allowing for full functional loading of the implants. Histologic and histometric analyses were performed on orofacial and mesiodistal undecalcified sections of the specimens obtained upon sacrifice after 4 and 16 weeks of functional loading. Bone-to-implant contact (BIC), multinucleated giant cells-to-implant contact (MIC), crestal bone level, and peri-implant bone density were histometrically assessed. RESULTS All 60 implants and 60 restorations were still in function after 4 and 16 weeks of loading in both test and control groups. No implant loss, no implant or abutment fracture, and no chipping of the restorations could be detected. Histometric analysis showed no statistically significant differences between zirconia and titanium implants in BIC, crestal bone level, and peri-implant bone density at both time points. Between 4 and 16 weeks, the crestal bone level around zirconia implants showed a small but statistically significant increase in its distance from the implant shoulder. MIC was very low on both implant types and both time points and decreased statistically significantly overtime. CONCLUSION The present two-piece zirconia implant showed a similar bone integration compared to the titanium implant with similar surface morphology after 4 and 16 weeks of loading.
Collapse
Affiliation(s)
- Simone F M Janner
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.,Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Michael Gahlert
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland.,Private Practice, Munich, Germany
| | - Dieter D Bosshardt
- Robert K. Schenk Laboratory of Oral Histology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Stefan Roehling
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.,Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Stefan Milz
- Anatomische Anstalt, Ludwig-Maximilians University, Munich, Germany
| | | | - Daniel Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - David L Cochran
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| |
Collapse
|
26
|
Dicationic Imidazolium-Based Ionic Liquid Coatings on Zirconia Surfaces: Physico-Chemical and Biological Characterization. J Funct Biomater 2017; 8:jfb8040050. [PMID: 29236088 PMCID: PMC5748557 DOI: 10.3390/jfb8040050] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 12/06/2017] [Accepted: 12/07/2017] [Indexed: 01/07/2023] Open
Abstract
In the present work, dicationic imidazolium-based ionic liquids (ILs) were investigated as multi-functional coatings on a zirconia (ZrO2) surface to prevent biofilm formation and enhance the wear performance of zirconia while maintaining the material’s compatibility with host cells. ILs containing phenylalanine and methionine were synthesized and deposited on zirconia. Intermolecular interactions driving IL deposition on zirconia were studied using X-ray photoelectron spectroscopy (XPS). Anti-biofilm activity and cell compatibility were evaluated in vitro after one and seven days, and wear performance was tested using a pin-on-disk apparatus. ILs were observed to form strong hydrogen bonds with zirconia. IL containing phenylalanine formed a stable film on the surface after one and seven days in phosphate-buffered saline (PBS) and artificial saliva and showed excellent anti-biofilm properties against Streptococcussalivarius and Streptococcussanguinis. Compatibility with gingival fibroblasts and pre-osteoblasts was maintained, and conditions for growth and differentiation were preserved. A significantly lower coefficient of friction and wear volume loss were observed for IL-coated surfaces as compared to non-coated substrates. Overall, zirconia is an emerging alternative to titanium in dental implants systems, and this study provides additional evidence of the materials’ behavior and IL coatings as a potential surface treatment technology for improvement of its properties.
Collapse
|
27
|
Kohal RJ, Spies BC, Bauer A, Butz F. One-piece zirconia oral implants for single-tooth replacement: Three-year results from a long-term prospective cohort study. J Clin Periodontol 2017; 45:114-124. [DOI: 10.1111/jcpe.12815] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/07/2017] [Indexed: 11/26/2022]
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry; Center for Dental Medicine; Medical Center - University of Freiburg; Faculty of Medicine; University of Freiburg; Freiburg Germany
| | - Benedikt C. Spies
- Department of Prosthetic Dentistry; Center for Dental Medicine; Medical Center - University of Freiburg; Faculty of Medicine; University of Freiburg; Freiburg Germany
| | - Annalena Bauer
- Department of Prosthetic Dentistry; Center for Dental Medicine; Medical Center - University of Freiburg; Faculty of Medicine; University of Freiburg; Freiburg Germany
| | - Frank Butz
- Department of Prosthetic Dentistry; Center for Dental Medicine; Medical Center - University of Freiburg; Faculty of Medicine; University of Freiburg; Freiburg Germany
| |
Collapse
|
28
|
Pieralli S, Kohal RJ, Lopez Hernandez E, Doerken S, Spies BC. Osseointegration of zirconia dental implants in animal investigations: A systematic review and meta-analysis. Dent Mater 2017; 34:171-182. [PMID: 29122237 DOI: 10.1016/j.dental.2017.10.008] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 10/17/2017] [Accepted: 10/18/2017] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To determine the osseointegration rate of zirconium dioxide (ZrO2) dental implants in preclinical investigations. DATA Data on the osseointegration rate was extracted considering the bone to implant contact (BIC), removal torque analysis (RTQ) and push-in tests. Meta analyses were conducted using multilevel multivariable mixed-effects linear regression models. The Šidák method was used in case of multiple testing. SOURCES An electronic screening of the literature (MEDLINE/Pubmed, Cochrane Library and Embase) and a supplementary manual search were performed. Animal investigations with a minimum sample size of 3 units evaluating implants made of zirconia (ZrO2) or its composites (ZrO2>50vol.%) were included. STUDY SELECTION The search provided 4577 articles, and finally 54 investigations were included and analyzed. Fifty-two studies included implants made from zirconia, 4 zirconia composite implants and 37 titanium implants. In total, 3435 implants were installed in 954 animals. CONCLUSIONS No significant influence of the evaluated bulk materials on the outcomes of interest could be detected. When comparing different animal models, significant differences for the evaluated variables could be found. These results might be of interest for the design of further animal investigations.
Collapse
Affiliation(s)
- Stefano Pieralli
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Straße 4-6, 14197 Berlin, Germany.
| | - Ralf-Joachim Kohal
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Emilia Lopez Hernandez
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sam Doerken
- Medical Center - University of Freiburg, Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Faculty of Medicine - University of Freiburg, Hebelstr. 11, 79104 Freiburg, Germany
| | - Benedikt Christopher Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Straße 4-6, 14197 Berlin, Germany
| |
Collapse
|
29
|
Sivaraman K, Chopra A, Narayan AI, Balakrishnan D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J Prosthodont Res 2017; 62:121-133. [PMID: 28827030 DOI: 10.1016/j.jpor.2017.07.003] [Citation(s) in RCA: 112] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/22/2017] [Accepted: 07/11/2017] [Indexed: 02/04/2023]
Abstract
PURPOSE Titanium based implant systems, though considered as the gold standard for rehabilitation of edentulous spaces, have been criticized for many inherent flaws. The onset of hypersensitivity reactions, biocompatibility issues, and an unaesthetic gray hue have raised demands for more aesthetic and tissue compatible material for implant fabrication. Zirconia is emerging as a promising alternative to conventional Titanium based implant systems for oral rehabilitation with superior biological, aesthetics, mechanical and optical properties. This review aims to critically analyze and review the credibility of Zirconia implants as an alternative to Titanium for prosthetic rehabilitation. STUDY SELECTION The literature search for articles written in the English language in PubMed and Cochrane Library database from 1990 till December 2016. The following search terms were utilized for data search: "zirconia implants" NOT "abutment", "zirconia implants" AND "titanium implants" AND "osseointegration", "zirconia implants" AND compatibility. RESULTS The number of potential relevant articles selected were 47. All the human in vivo clinical, in vitro, animals' studies were included and discussed under the following subheadings: Chemical composition, structure and phases; Physical and mechanical properties; Aesthetic and optical properties; Osseointegration and biocompatibility; Surface modifications; Peri-implant tissue compatibility, inflammation and soft tissue healing, and long-term prognosis. CONCLUSIONS Zirconia implants are a promising alternative to titanium with a superior soft-tissue response, biocompatibility, and aesthetics with comparable osseointegration. However, further long-term longitudinal and comparative clinical trials are required to validate zirconia as a viable alternative to the titanium implant.
Collapse
Affiliation(s)
- Karthik Sivaraman
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India.
| | - Aditi Chopra
- Department of Periodontology, Manipal College of Dental Sciences, Manipal University, Manipal, India
| | - Aparna I Narayan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| | - Dhanasekar Balakrishnan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| |
Collapse
|
30
|
Long-term stability of an injection-molded zirconia bone-level implant: A testing protocol considering aging kinetics and dynamic fatigue. Dent Mater 2017. [DOI: 10.1016/j.dental.2017.06.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
31
|
Spies BC, Pieralli S, Vach K, Kohal RJ. CAD/CAM-fabricated ceramic implant-supported single crowns made from lithium disilicate: Final results of a 5-year prospective cohort study. Clin Implant Dent Relat Res 2017; 19:876-883. [DOI: 10.1111/cid.12508] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 04/05/2017] [Accepted: 05/17/2017] [Indexed: 11/27/2022]
Affiliation(s)
- Benedikt Christopher Spies
- Department of Prosthetic Dentistry; Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg; Germany
| | - Stefano Pieralli
- Department of Prosthetic Dentistry; Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg; Germany
| | - Kirstin Vach
- Medical Center-University of Freiburg; Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics; Freiburg Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry; Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg; Germany
| |
Collapse
|
32
|
Cionca N, Hashim D, Mombelli A. Zirconia dental implants: where are we now, and where are we heading? Periodontol 2000 2016; 73:241-258. [DOI: 10.1111/prd.12180] [Citation(s) in RCA: 141] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
33
|
Pieralli S, Kohal R, Jung R, Vach K, Spies B. Clinical Outcomes of Zirconia Dental Implants: A Systematic Review. J Dent Res 2016; 96:38-46. [DOI: 10.1177/0022034516664043] [Citation(s) in RCA: 118] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Affiliation(s)
- S. Pieralli
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center–University of Freiburg, Freiburg, Germany
| | - R.J. Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center–University of Freiburg, Freiburg, Germany
| | - R.E. Jung
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - K. Vach
- Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Medical Center–University of Freiburg, Freiburg, Germany
| | - B.C. Spies
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center–University of Freiburg, Freiburg, Germany
| |
Collapse
|