1
|
Moreira PM, Carvalho GLM, de Castro Albuquerque R, André CB. Effect of hydrofluoric acid and self-etch ceramic primers on the flexural strength and fatigue resistance of glass ceramics: A systematic review and meta-analysis of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2024; 60:198-210. [PMID: 39027733 PMCID: PMC11254839 DOI: 10.1016/j.jdsr.2024.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 05/06/2024] [Accepted: 06/04/2024] [Indexed: 07/20/2024] Open
Abstract
This systematic review evaluated the effect of different hydrofluoric acid (HF) etching regimens and a self-etch ceramic primer (SECP) on the flexural strength (FS) and fatigue failure load (FFL) of glass-ceramic materials.The identification of relevant studies was conducted by two authors in five databases: PubMED, Scopus, Web Of Science, LILACS and Virtual Health Library (BVS) until July 2022 with no year limit. The analysis was conducted in RevMan 5.4.1 Software (Cochrane Collaboration) using Random effect model at 5 %. The risk of bias of the included studies were assessed. From the 5349 articles identified, 34 were included for quantitative analysis. Meta-analysis showed that for predominantly glassy ceramics, etching with HF 5 % had no significant impact on FS, however, HF acid etching with concentrations greater than 5 % negatively impacted FS. For lithium disilicate glass-ceramics (LDGC) HF acid etching, negatively influenced FS, while increasing the FFL. HF etching negatively affected FS of hybrid ceramics. The self-etch ceramic primer and HF acid etching showed a similar impact on FFL and FS. This meta-analysis indicates that the impact of SECP and HF acid etching on the mechanical behavior of glass ceramics is material-dependent.
Collapse
Affiliation(s)
- Paulo Matias Moreira
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | | | - Rodrigo de Castro Albuquerque
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Carolina Bosso André
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| |
Collapse
|
2
|
Bresser RA, Carvalho MA, Naves LZ, Melma H, Cune MS, Gresnigt MMM. Biomechanical behavior of molars restored with direct and indirect restorations in combination with deep margin elevation. J Mech Behav Biomed Mater 2024; 152:106459. [PMID: 38394767 DOI: 10.1016/j.jmbbm.2024.106459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/30/2024] [Accepted: 02/05/2024] [Indexed: 02/25/2024]
Abstract
STATEMENT OF PROBLEM The existing knowledge is insufficient for comprehending the fatigue survival and fracture resistance of molars that have deep approximal direct and indirect restorations, whether with or without deep margin elevation (DME). PURPOSE The aim of this laboratory and in silico study is to investigate the fatigue survival, fracture strength, failure pattern and tooth deformation of molars restored with DME in combination with a direct or indirect restoration. MATERIAL AND METHODS This study utilized 45 extracted sound human molars, divided into three groups (n = 15). Standardized 100% inter-cuspal inlay preparations were performed, extending 2 mm below the CEJ and immediate dentin sealing (IDS) was applied. Group 1 (Co_1) was restored with direct composite; Group 2 (Hyb_2) with a 2 mm DME of direct composite and a glass-ceramic lithium disilicate restoration; Group 3 (Cer_3) a glass-ceramic lithium disilicate restoration. All specimens were exposed to a fatigue process involving thermal-cyclic loading (50N for 1.2 × 106 cycles at 1.7 Hz, between 5 and 55 °C), if teeth survived, they were fractured using a load-to-failure test and failure types were analyzed. Finite element analysis (FEA) was conducted to assess tooth deformation and tensile stress in the restorations. Statistical evaluation of fracture strength was conducted using the Kruskal-Wallis test. Fisher's exact test was utilized to analyze the fracture types and repairability. A statistical significance level of α < 0.05 was set for all analyses. RESULTS All specimens successfully withstood the fatigue testing procedure, and no statistically significant differences in fracture strength were observed among the three groups (P > 0.05). The Fisher's exact test indicated a significant association between the restorative material and fracture type (F2 = 18.315, df = 2, P = 0.004), but also for repairability (F2 = 13.725, df = 2, P = 0.001). Crown-root fractures were significantly more common in the Cer_3 group compared to the Co_1 group (P = 0.001) and the Co_1 group had significantly more repairable fractures (F2 = 13.197, df = 2, P = 0.001). FEA revealed comparable outcomes of deformation among models and higher maximum tensile stress on models with higher frequency of catastrophic failures. CONCLUSIONS All tested restoration materials exhibited comparable fatigue survival and fracture strength in this laboratory and in silico study. However, it is important to recognize the potential for more severe and irreparable fractures when opting for deeply luted glass-ceramic inlay restorations in clinical practice. In such cases, it would be prudent to consider the alternative option being a direct composite approach, because of its more forgiving fracture types and repairability. CLINICAL IMPLICATIONS Molars with deep approximal direct and indirect restorations, whether with or without DME, are comparable in their fatigue survival and fracture resistance to withstand intra-oral forces. Deep direct restorations exhibit more repairable fractures compared to deeply luted glass-ceramics.
Collapse
Affiliation(s)
- Rijkje A Bresser
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands.
| | - Marco A Carvalho
- Dental School, Evangelical University of Goias, Anapolis, Brazil
| | - Lucas Z Naves
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands
| | - H Melma
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands
| | - Marco S Cune
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; St. Antonius Hospital Nieuwegein, Department of Oral Maxillofacial Surgery, Prosthodontics and Special Dental Care, Nieuwegein, the Netherlands
| | - Marco M M Gresnigt
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; Martini Hospital, Department of Special Dental Care, Groningen, the Netherlands
| |
Collapse
|
3
|
Pilecco RO, Machry RV, Ribeiro VF, Dal Piva AMDO, Tribst JPM, Kleverlaan CJ, Moraes RR, Pereira GKR. Impact of try-in paste removal on the fatigue behavior of bonded lithium disilicate ceramics. J Mech Behav Biomed Mater 2024; 151:106394. [PMID: 38218045 DOI: 10.1016/j.jmbbm.2024.106394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/06/2024] [Accepted: 01/07/2024] [Indexed: 01/15/2024]
Abstract
This in vitro study assessed the effectiveness of three cleaning protocols (air-water spray, 37% phosphoric acid, or Ivoclean) on lithium disilicate restorations' fatigue behavior after try-in paste application, compared to a clean condition. Lithium disilicate discs (IPS e.max CAD, Ivoclar) with Ø-= 12 mm and 1 mm thickness were prepared from prefabricated CAD-CAM blocks, polished, subjected to CAD-CAM milling topography simulation and crystallization. After, etching with 5% hydrofluoric acid and the application of try-in paste (Variolink try-in paste shade white; load of 2.5 N for 5 min) was performed. Discs that received try-in paste were divided into three groups according to the removal protocol: SPRAY - air-water spray for 30 s; HPO - active application of 37% phosphoric acid for 60 s; IVOC - application of Ivoclean for 20 s. Control group (CTRL group) did not receive the try-in paste application. Half of the specimens (n= 15) were tested in the baseline condition (24 h up to 7 days), and the others underwent 25,000 thermal cycles (5 - 55 °C) + 210 days of distilled water storage (37 °C). Additional specimens (n= 3) underwent monotonic testing (1 mm/min). Fatigue testing involved a cyclic fatigue approach (20 Hz, initial load = 100 N - 5000 cycles, step size = 50 N - 10,000 cycles) until a visible crack appeared. Fractographic and topographic analyses were performed. Fatigue data were statistically analyzed with two-way ANOVA, Kaplan-Meier log-rank (Mantel-Cox), and independent t-test (α= 0.05). In the baseline condition, the IVOC group resulted in a superior fatigue behavior compared to the CTRL and SPRAY groups, but similar to the HPO group. The HPO and SPRAY presented a similar fatigue behavior to the CTRL group. It was noticed a decrease in fatigue behavior after aging, which resulted in all the cleaning protocols leading to similar fatigue behavior compared to the CTRL group. On the SPRAY group surface, try-in pastes remnants were noticed. In summary, despite a detrimental impact at baseline conditions, all tested cleaning protocols seem proper to remove the try-in paste from the ceramic's surface in the long-term evaluation.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Universidade Federal de Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Universidade Federal de Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | | | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands.
| | - Rafael R Moraes
- Graduate Program in Dentistry, Universidade Federal de Pelotas (UFPel), Pelotas, RS, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Universidade Federal de Santa Maria (UFSM), Santa Maria, RS, Brazil.
| |
Collapse
|
4
|
Pilecco RO, da Rosa LS, Pereira GKR, Tribst JPM, May LG, Valandro LF. The loss of resin cement adhesion to ceramic influences the fatigue behavior of bonded lithium disilicate restorations. J Mech Behav Biomed Mater 2023; 148:106169. [PMID: 37837872 DOI: 10.1016/j.jmbbm.2023.106169] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/06/2023] [Accepted: 10/06/2023] [Indexed: 10/16/2023]
Abstract
When partial and/or non-retentive preparation, such as those for occlusal veneers, is indicated, a proper and stable adhesion is essential. Therefore, the aim of this in vitro study was to evaluate the effect of loss of adhesion in different regions of the bonding interface on the fatigue behavior of simplified lithium disilicate restorations. For this, lithium disilicate (IPS e.max CAD) discs (1 mm thick and Ø = 10 mm) were fabricated, polished with #400-, #600-, #1200-grit silicon carbide (SiC) papers, and crystallized. As substrate, fiber-reinforced resin epoxy discs (2.5 mm thick and Ø = 10 mm) were fabricated and polished with #600-grit SiC paper. The ceramic bonding surface was treated with 5% hydrofluoric acid and a silane-containing primer (Monobond N), while the substrate was etched with 10% hydrofluoric acid followed by the application of the bonding system primers (Primer A + B). A lacquer (nail polish) was used to simulate the loss of adhesion in specific areas according to the study design to compose the testing groups: bonded (control; did not received nail polish application); - non-bonded (loss of adhesion in the whole specimen area); - margin (loss of adhesion in the ceramic margin); - center (loss of adhesion in the ceramic central area). The adhesive area of partially bonded groups was 50% of the adhesive surface. Then, the discs (n = 12) were bonded to the respective substrate using a resin cement (Multilink N), light-cured, water-stored for 90 days, and subjected to thermocycling (25,000 cycles, 5° to 55 °C) before testing. A cyclic fatigue test was run (20 Hz, initial load of 200 N for 5000 cycles, 50 N step size for 10,000 cycles each until specimen failure), and the fatigue failure load and number of cycles for failure were recorded. As complementary analysis, finite element analysis (FEA) and scanning electron microscopy analysis were performed. Kaplan-Meier log-rank (Mantel-Cox) was conducted for survival analysis. The results showed that as the loss of adhesion reaches the central area, the worse is the fatigue behavior and the higher is the stress peak concentration in the ceramic bonding surface. The bonded specimens presented better fatigue behavior and stress distribution compared to the others. In conclusion in a non-retentive preparation situation, proper adhesion is a must for the restoration fatigue behavior even after aging; while the loss of adhesion reaches central areas the mechanical functioning is compromised.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, the Netherlands.
| | - Liliana Gressler May
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| |
Collapse
|
5
|
Porto TS, Medeiros da Silva IG, de Freitas Vallerini B, Fernando de Goes M. Different surface treatment strategies on etchable CAD-CAM materials: Part 1-Effect on the surface morphology. J Prosthet Dent 2023; 130:761-769. [PMID: 35094771 DOI: 10.1016/j.prosdent.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 10/12/2021] [Accepted: 10/12/2021] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM Polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials have either a high content of ceramic filler particles or a ceramic network structure. Proper etching of these materials is challenging. Therefore, it is relevant to assess different surface etching strategies and morphological alterations as a result of these techniques. PURPOSE The purpose of this 2-part in vitro study was to evaluate different etching strategies on the surface roughness and its relationship to the surface contact angle with a subsequent morphological characterization of different CAD-CAM materials. MATERIAL AND METHODS Two CAD-CAM polymer-based materials and 1 CAD-CAM ceramic material were selected for this study. The materials were treated with different strategies, including a combination of airborne-particle abrasion and an application of 9% hydrofluoric acid etching. After the surface treatment, roughness measurements (Sa) were assessed by using an optical profilometer on an area of 1.47 mm2. Subsequently, the contact angle on the surface was examined by means of the sessile drop technique and an optical contact angle meter. The data were analyzed by using a 2-way analysis of variance, the post hoc Tukey test (α=.05), and the Pearson correlation coefficient. RESULTS The 3 materials tested showed an increase in surface roughness when treated with surface airborne-particle abrasion. However, the materials with polymer in their composition concomitantly increased the contact angle. More hydrophilic surfaces were observed when hydrofluoric acid was applied, regardless of the composition of the materials. The surface roughness presented a strong positive linear tendency in the surface treatments used. CONCLUSIONS The application of airborne-particle abrasion on the surface of the polymer-based CAD-CAM materials increased the roughness and contact angle. However, the application of acid etching after the airborne-particle abrasion decreased the contact angle for polymer-based CAD-CAM materials, resulting in considerable enhancement of the surface quality for proper bonding.
Collapse
Affiliation(s)
- Thiago Soares Porto
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
| | - Italo Guimaraes Medeiros da Silva
- Researcher, Department of Macromolecular Science and Engineering, School of Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Bruna de Freitas Vallerini
- PhD Candidate, Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, Sao Paulo State University, UNESP, Sao Paulo, Brazil
| | - Mario Fernando de Goes
- Professor, Department of Restorative Dentistry (Dental Materials Area), Piracicaba Dental School, University of Campinas, UNICAMP, Sao Paulo, Brazil
| |
Collapse
|
6
|
Cheng PJ, Liu SM, Huang SM, Wang JC, Hung CC, Chen WC. Survival assessment of fractured porcelain-fused-to-metal crowns surface roughened by sandblasted and repaired by composite resin after in vitro thermal fatigue. J Dent Sci 2023; 18:1706-1715. [PMID: 37799887 PMCID: PMC10547947 DOI: 10.1016/j.jds.2023.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/02/2023] [Indexed: 01/15/2023] Open
Abstract
Background/purpose Intraoral repair usually takes the convenience of the patient's daily life as the starting point, taking into account the bonding strength, operational feasibility, and safety. This study aimed to evaluate the survival of composite resin by simulating cavity fracture repair in porcelain-fused-to-metal (PFM) crowns and referring to the G.V. Black classification of caries as ceramic- and metal-site exposure. Materials and methods Mechanical sandblast experimental and a nonsandblast control groups comprised 120 samples, and interfacial locking was enhanced through acid etching, bonding, and light-curing composite resin restoration. Classes of VI buccal (B), III mesial (M), and IV mesiobuccal (MB) types, were investigated. Load tests were performed on two sets, with one set at room temperature for 24 h and the other via thermal cycling at 5 °C/50 °C 720 times. Loading was gradually applied to the samples until a maximum of 450 N was reached. Results Results showed that 24 h survival rates of B-, M - , and MB-repaired PFM crowns were 88%, 84%, and 88%, respectively. The repaired PFM survival rates for B, M, and MB were 52%, 44%, and 28%, respectively, after thermal cycling and loading tests. Multiple logistic regression and chi-square test (α = 0.05) showed that the regression results of factors affecting survival assessment were only significant between groups after thermal fatigue (P < 0.05). Survival rate of repairing metal-site in the MB model was significantly higher than that of ceramic-sites repairing in non-blasted samples. For the MB cavity model, sandblasting can significantly improve the survival rate of the repair of ceramic parts in the MB model (P < 0.05). Conclusion Our results suggest that sandblasting can be further considered, especially for MB cavity fractures when ceramic-site restorations are required.
Collapse
Affiliation(s)
- Po-Jen Cheng
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
- Division of Dental Research, Department of Dentistry, Kaohsiung Municipal Min-Sheng Hospital, Kaohsiung, Taiwan
| | - Shih-Ming Liu
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
| | - Ssu-Meng Huang
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
| | - Jen-Chyan Wang
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chun-Cheng Hung
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Wen-Cheng Chen
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
7
|
Dapieve KS, Pilecco RO, Temp RW, Villetti MA, Pereira GKR, Valandro LF. Adhesion to lithium disilicate glass-ceramics after aging: Resin viscosity and ceramic surface treatment effects. J Mech Behav Biomed Mater 2023; 142:105819. [PMID: 37062098 DOI: 10.1016/j.jmbbm.2023.105819] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 03/26/2023] [Accepted: 03/30/2023] [Indexed: 04/08/2023]
Abstract
OBJECTIVE To evaluate the influence of intaglio ceramic surface treatments, resin cement viscosities, and storage regimens on the microshear bond strength of lithium disilicate ceramic. In addition, to investigate the dynamic viscosity of the resin-based luting agents. MATERIALS AND METHODS Ceramic slices were randomly allocated into eight groups (n = 19) considering three factors: ceramic surface treatment (hydrofluoric acid followed by silane, HF; or self-etching ceramic primer, E&P), resin cement viscosity (high, HIGH; or low, LOW) and storage regimen (baseline or aging). Surface treatments were performed, resin cement cylinders were built and microshear bond strength tests (μSBS, wire-loop method, speed: 1.0 mm/min) were run according to the storage factor. Failure mode, topographic and dynamic viscosity (37 °C; shear rate of 1.0-100 s-1) of resin cement components (base, high and low catalyst) were also performed. RESULTS Resin cement viscosity and the association among ceramic surface treatment, resin cement viscosity, and storage regimen were statistically significant factors (p < 0.05). Worse behavior was identified for the E&P_HIGH group compared to the E&P_LOW and HF_LOW in the baseline condition. After aging, the HF_HIGH group (16.78 MPa) presented the worst result among the aged groups (21.44-25.25 MPa). Most of the failures were adhesive. Surface micrographs revealed a distinct pattern after etching, more aggressive by HF and milder by E&P. High viscosity catalyst is 5.3 and 8.5-fold more viscous than the base and low viscosity catalyst, respectively (high > base > low). CONCLUSION Differences in filler content can impact the resin viscosity of the material (more fillers increase the viscosity), which in turn can influence the bond strength of a lithium disilicate ceramic, depending on the surface treatment and storage regimen.
Collapse
|
8
|
A brief review on fatigue test of ceramic and some related matters in Dentistry. J Mech Behav Biomed Mater 2023; 138:105607. [PMID: 36549251 DOI: 10.1016/j.jmbbm.2022.105607] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/28/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.
Collapse
|
9
|
Abstract
Resin-bonded ceramic restorations are common treatment options. Clinical longevity of resin-bonded ceramic restorations depends on the quality and durability of the resin-ceramic bond. The type and composition of the specific ceramic determines the selection of the most effective bonding protocol. Such protocol typically includes a surface pretreatment step followed by application of a priming agent. Understanding of fundamental ceramic properties and chemical compositions enables the clinician to make proper material selection decisions for clinically successful and long-lasting restorations. Based on research accrued over the past decades, this article reviews and discusses current resin-bonding protocols to most commonly used dental ceramics.
Collapse
Affiliation(s)
- Markus B Blatz
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA 19104, USA.
| | - Julian Conejo
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA 19104, USA
| | - Amirah Alammar
- Sijam Medical Center, Northern Ring Road, Alghadeer District, Riyadh, Saudi Arabia
| | - Jose Ayub
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA 19104, USA
| |
Collapse
|
10
|
Dapieve KS, Pilecco RO, Pivetta JP, Machry RV, Werner A, Kleverlaan CJ, Pereira GKR, Valandro LF. Is the application of a silane-based coupling agent necessary to stabilize the fatigue performance of bonded simplified lithium disilicate restorations? J Mech Behav Biomed Mater 2021; 126:104989. [PMID: 34864398 DOI: 10.1016/j.jmbbm.2021.104989] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/16/2021] [Accepted: 11/18/2021] [Indexed: 11/16/2022]
Abstract
This study evaluated the influence of ceramic surface conditioning and storage regimen (baseline vs. aging) on the fatigue performance of simplified lithium disilicate glass-ceramic restorations. A total of 90 ceramic discs (Ø= 10 mm; thickness= 1.0 mm) were allocated into 6 groups (n= 15), considering 2 factors: "ceramic surface treatment" - CA (only silane-based coupling agent, Monobond N), HF (5% hydrofluoric acid etching), or HF+CA (5% HF acid etching plus silane-based coupling agent); and "storage regimen" - baseline (24 hours - 5 days of distilled water at 37 °C), or long-term aging (180 days of distilled water at 37 °C + 25,000 thermal cycles). After intaglio ceramic conditioning, adhesive bonding (Multilink N) was performed onto epoxy resin discs (Ø= 10 mm; thickness= 2.5 mm) and the bonded sets were subjected to step-stress fatigue tests (initial load: 200 N; step-size: 50 N; 10,000 cycles per step; 20 Hz). Fatigue data were analyzed using Kaplan-Meier and Weibull statistical analyses. Fractography and topography analyses were also conducted. The fatigue findings demonstrated that the performance among groups for both baseline and aging conditions maintained a tendency: the CA groups had the worst behavior (baseline: 893 N/143,667 cycles; aging: 639 N/84,179 cycles), while the surface etching with HF (baseline: 1247 N/214,333 cycles; aging: 816.67 N/128,333 cycles) and HF+CA groups (baseline: 1290 N/222,333 cycles; aging: 900 N/145,000 cycles) had no statistically significant difference between them. The aging protocol reduced the performance of all groups. The groups with better fatigue performance (HF and HF+CA) did not have statistical differences regarding structural reliability (Weibull modulus). Most failures were radial cracks from the cementation interface, except for CA aging specimens, with 27% failing from debonding. The HF etching led to noteworthy surface topographical alterations. Micromechanical interlocking resulting from HF acid etching remained prevalent in the fatigue behavior. Thus, the silane-based coupling agent (Monobond N) does not need to be applied after HF etching in terms of fatigue behavior outcomes.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Rafaela Oliveira Pilecco
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Jordana Pavanelo Pivetta
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renan Vaz Machry
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Arie Werner
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, the Netherlands.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
11
|
Machry RV, Cadore-Rodrigues AC, Packaeser MG, Lorenzett E, Burgo TADL, Pereira GKR, Valandro LF. Influence of surface treatment of resin composite substrate on the load-bearing capacity under fatigue of lithium disilicate monolithic simplified restorations. J Mech Behav Biomed Mater 2021; 124:104792. [PMID: 34488172 DOI: 10.1016/j.jmbbm.2021.104792] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/20/2021] [Accepted: 08/22/2021] [Indexed: 10/20/2022]
Abstract
This study evaluated the influence of surface treatments of resin composite substrate on the fatigue behavior of adhesively cemented lithium disilicate glass-ceramic simplified restorations. CAD/CAM lithium disilicate ceramic blocks were shaped into discs (N = 60, Ø = 10 mm; thickness = 1.0 mm). Resin composite discs (N = 60, Ø = 10 mm, thickness = 2 mm) were allocated into four groups considering the "surface treatment" factor: Ctrl - no surface treatment; Bur - grinding with coarse diamond bur (#3101G, KG Sorensen); PA - etching with 37% phosphoric acid (15 s); AA - air abrasion with alumina particles (45 μm, 10 mm distance, 2.8 bars, 10 s). The surface topography, the roughness, the fractal dimension (estimated by the box-counting method) and the contact angle analyses were performed after the surface treatments. The lithium disilicate discs were etched (5% hydrofluoric acid, 20 s), silanized and adhesively cemented (Multilink N, Ivoclar Vivadent) on the resin composite discs. The samples (bonded restoration set) were subjected to a step-stress fatigue test at 20 Hz, 10,000 cycles/step with a step-size of 100 N applied on the ceramic surface, having ceramic up and resin composite down. Fractographic analysis was performed. The fatigue data (Fatigue Failure Load - FFL; and Cycles for Failure - CFF) were analyzed by Kaplan Meier with Mantel-Cox log-rank post-hoc tests (α = 0.05). No statistical difference for fatigue performance could be found among the groups (FFL means: 820-867 N; CFF means: 53,195-61,090 cycles). The bur group showed higher surface roughness and contact angle values. The PA group has the highest average fractal dimension. Therefore, the resin composite surface treatment induces topographical changes, however, it has no effect on the fatigue behavior of lithium disilicate restorations.
Collapse
Affiliation(s)
- Renan Vaz Machry
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ezequiel Lorenzett
- Post-Graduate Program in Physics, Physics Department, Federal University of Santa Maria, Brazil.
| | | | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| |
Collapse
|
12
|
Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP. Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 2021; 123:104760. [PMID: 34418777 DOI: 10.1016/j.jmbbm.2021.104760] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/03/2021] [Indexed: 11/17/2022]
Abstract
The fatigue behavior and FEA analysis of different ceramic materials cemented over distinct substrates for implant-supported crowns were evaluated in this study. Discs of 10 mm in diameter of both restorative and substrate materials were made and randomly allocated into pairs (n = 15) considering the two study factors: 'restorative ceramic material' (1 mm thickness) - polymer-infiltrated ceramic network (PICN), lithium disilicate (LD), zirconia-reinforced lithium silicate (ZLS), or translucent zirconia (TZ); and 'foundation substrate' (2 mm thickness) - polyetheretherketone (Peek) or yttrium-stabilized zirconia (YZ). Adhesive cementation was made with a dual cure resin cement. Fatigue testing was run using the step-stress methodology: initial load of 200 N for 5000 cycles, followed by steps of 10,000 cycles starting at 400 N up to 2800 N or until failure, step size of 200 N, frequency of 20 Hz. Data were analyzed by the Kaplan Meier and log-rank post-hoc tests. Fractography analysis (stereomicroscope and SEM) and FEA were also performed. Both factors under study and their interaction statistically influenced the fatigue failure load (FFL), cycles for failure (CFF) and survival rates (p < 0.001). The restorative materials bonded to YZ had higher FFL and CFF than when adhering to Peek, while restorative materials with more crystalline content (TZ and ZLS) showed higher FFL and CFF than LD and PICN. The fractography analysis showed that all materials bonded to YZ resulted in failures starting at the occlusal surface (Hertzian cone cracks), while materials bonded to Peek had radial cracks from the ceramic-cement intaglio surface. FEA analysis showed that tensile stress concentration decreased in the intaglio surface when testing the restorative material over a stiffer (YZ) foundation substrate. In addition, the higher the restorative material's crystalline content, the more the stress is concentrated within the material (TZ > ZLS ≥ LD > PICN) when bonded to the same foundation substrate. Thus, it concluded that a stiffer foundation substrate (YZ) enhances the load-bearing capacity under fatigue of the restorative set; that restorative materials with higher crystalline content results in higher fatigue performance of the set, regardless of the foundation used; and that the foundation material influences the failure pattern of the restorative set.
Collapse
Affiliation(s)
- Pablo Machado Soares
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
13
|
Pilecco RO, Dalla-Nora F, Guilardi LF, Pereira GKR, de Andrade GS, de Melo RM, Valandro LF, Rippe MP. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: Effect on the fatigue behavior of the bonded ceramic. J Mech Behav Biomed Mater 2021; 121:104604. [PMID: 34087550 DOI: 10.1016/j.jmbbm.2021.104604] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/11/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.5 mm and 1.5 mm of thickness) were produced in different ways: milled in a CAD/CAM system (CAD/CAM - control group); mirror-polished (POL group); produced in-lab and ground with #60 silicon carbide paper (SiC group); with #60 wood sandpaper (WS group); with a fine diamond bur (DB group); or with a CAD/CAM bur adapted in a handpiece with a custom mandrel (MANDREL group). The ceramic discs were adhesively luted (Multilink N) onto dentin analogue discs (Ø = 12 mm and 2 mm of thickness) and fatigue testing (n = 19 discs) was performed by step-stress methodology (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Surface roughness and contact angle analysis were also performed. According to Kaplan-Meier and post-hoc Mantel-Cox (log-rank), distinct fabrication methods affected the fatigue performance of bonded glass-ceramic discs (p< 0.001). The CAD/CAM group presented the lowest fatigue failure loads (1250 N) and number of cycles for failure (185,000), while the POL groups obtained the highest results (1752 N; 284,444 cycles). The in-lab groups had intermediate values (1355 - 1526 N; 206,052 - 238,684 cycles). Polished specimens presented the lowest roughness values (Ra = 0.041 μm), while the SiC (1.604 μm), WS (1.701 μm), and MANDREL (1.867 μm) groups showed statistically similar roughness values to the CAD/CAM group (1.738 μm). Despite differences before etching, the contact angle was similar among the milled and simulated groups after etching, except for the polished group. Even with some topographic similarities, the tested in-lab simulation methods were not able to mimic the milled specimens in terms of fatigue findings, leading to distinct magnitude of overestimations of the results.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Dalla-Nora
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
14
|
Step-stress vs. staircase fatigue tests to evaluate the effect of intaglio adjustment on the fatigue behavior of simplified lithium disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2020; 113:104091. [PMID: 33032009 DOI: 10.1016/j.jmbbm.2020.104091] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 09/05/2020] [Accepted: 09/14/2020] [Indexed: 11/24/2022]
Abstract
The aim of the study was to compare the outcomes for the fatigue mechanical behavior of bonded simplified lithium disilicate restorations, with and without an internal adjustment by grinding with diamond bur in running two fatigue tests: Staircase and Step-stress testing approaches. Ceramic discs (IPS e.max CAD) were prepared (Ø = 10 mm; thickness = 1.0 mm), submitted to an in-lab simulation of CAD/CAM milling (#60 SiC paper) and allocated into 2 groups according to the internal adjustment by grinding of the cementation surface: no adjustment (CTRL); or grinding with a coarse diamond bur (GR). Adhesive cementation (Multilink N) was performed onto epoxy resin discs (Ø = 10 mm; thickness = 2 mm) after ceramic/epoxy surface treatments. The cemented assemblies of each group were randomly assigned into 2 subgroups considering two fatigue tests (n = 15): Staircase - SC (250,000 cycles; 20 Hz), or Step-stress - SS (10,000 cycles per step; 20 Hz). Roughness, topographic and fractographic analyses were additionally performed. Statistical analyses were carried out using the Dixon and Mood method for Staircase data, and Kaplan-Meier and Mantel-Cox (log-rank) tests for Step-stress data. Ceramic restorations having its intaglio surface ground (GR group: SC test = 306.67 N; SS test = 646.67 N) presented lower fatigue failure load (FFL) values than the CTRL group (SC test = 879.28 N; SS test = 1090.00 N), regardless of the fatigue testing approach. The percentage of mean FFL decrease comparing the CTRL to GR group was higher for SC (65.1%) than the SS (40.7%) approach. However, a different total number of cycles was applied for each method. Both fatigue tests were able to detect the negative effect of internal adjustments of lithium disilicate glass-ceramic simplified restorations on their mechanical behavior. Therefore, both methods can be applied for similar evaluations (fatigue testing for ceramic restorations).
Collapse
|
15
|
Dapieve KS, Machry RV, Pilecco RO, Kleverlaan CJ, Rocha Pereira GK, Venturini AB, Valandro LF. One-step ceramic primer as surface conditioner: Effect on the load-bearing capacity under fatigue of bonded lithium disilicate ceramic simplified restorations. J Mech Behav Biomed Mater 2020; 104:103686. [DOI: 10.1016/j.jmbbm.2020.103686] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/06/2020] [Accepted: 02/07/2020] [Indexed: 10/25/2022]
|
16
|
Dartora G, Rocha Pereira GK, Varella de Carvalho R, Zucuni CP, Valandro LF, Cesar PF, Caldas RA, Bacchi A. Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution. J Mech Behav Biomed Mater 2019; 100:103401. [PMID: 31445400 DOI: 10.1016/j.jmbbm.2019.103401] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/14/2019] [Accepted: 08/19/2019] [Indexed: 11/15/2022]
Abstract
This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars were randomly assigned into 03 groups (n = 16) and restored with endocrowns (LD - lithium disilicate glass-ceramic or PICN - polymer-infiltrated ceramic network) or with direct composite restorations. Fatigue testing followed a step-stress approach (initial maximum load of 200 N and 5000 cycles, incremental step load of 200N and 10,000 cycles/step, being the specimens loaded until failure or to a maximum of 135,000 cycles at 2800 N). The fatigue failure load and number of cycles until failure were recorded and statistically analyzed. Fractographic and finite element (FEA) analyzes were conducted as well. There were no differences in fatigue failure load, number of cycles until fracture and mean survival probabilities among groups. However, indirect endocrowns had higher mechanical structural reliability, and LD restorations lasted more time before start to failing. FEA showed that the stress concentration in tooth tissues was higher for the resin composite, followed by PICN and LD in a decreasing order. Almost all fractures were restricted to the restorative material (without tooth involvement), and origins were identified at occlusal surface. The type of restoration did not influence the fatigue failure load, number of cycles until fracture and mean survival probabilities of the restorative strategies. Despite that, the mechanical structural reliability of endocrowns, especially those made of lithium disilicate, was higher and lasted more time before start to failing.
Collapse
Affiliation(s)
- Gustavo Dartora
- MSciD Post-Graduate Program in Dentistry, Meridional Faculty, IMED, Passo Fundo, Brazil.
| | | | | | - Camila Pauleski Zucuni
- MSciD and PhD Post-Graduate Program in Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Paulo Francisco Cesar
- Department of Biomaterials and Oral Biology, University of São Paulo, USP, São Paulo, Brazil.
| | | | - Atais Bacchi
- MSciD Post-Graduate Program in Dentistry, Meridional Faculty, IMED, Passo Fundo, Brazil.
| |
Collapse
|
17
|
Lawson NC, Jurado CA, Huang CT, Morris GP, Burgess JO, Liu PR, Kinderknecht KE, Lin CP, Givan DA. Effect of Surface Treatment and Cement on Fracture Load of Traditional Zirconia (3Y), Translucent Zirconia (5Y), and Lithium Disilicate Crowns. J Prosthodont 2019; 28:659-665. [PMID: 31145492 DOI: 10.1111/jopr.13088] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2019] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To determine if surface treatment and cement selection for traditional 3 mol% yttria partially stabilized zirconia (3Y-PSZ), "translucent" 5 mol% yttria-stabilized zirconia (5Y-Z), or lithium disilicate crowns affected their fracture load. MATERIALS AND METHODS Crowns with 0.8 mm uniform thickness (96, n = 8/group) were milled of 3Y-PSZ (Lava Plus), 5Y-Z (Lava Esthetic), or lithium disilicate (e.max CAD) and sintered/crystallized. Half the crowns were either particle-abraded with 30 µm alumina (zirconias) or etched with 5% hydrofluoric acid (lithium disilicate), and the other half received no surface treatment. Half the crowns from each group were luted with resin-modified glass ionomer (RMGI, RelyX Luting Plus) and half were luted with a resin cement (RelyX Unicem 2) to resin composite dies. Crowns were load cycled (100,000 cycles, 100 N force, 24°C water) and then loaded with a steel indenter until failure. A three-way ANOVA examined the effects of material, cement, and surface treatment on fracture load. Post-hoc comparisons were performed with the Tukey-Krammer method. RESULTS Fracture load was signficiantly different for materials and cements (p < 0.0001) but not surface treatments (p = 0.77). All lithium disilicate crowns luted with RMGI failed in fatigue loading cycling; 3Y-PSZ and 5Y-Z crowns luted with resin showed a higher fracture load compared with RMGI (p < 0.001). With resin cement, there was no signficant difference in fracture load between 5Y-Z and lithium disiliciate (p = 1) whereas 3Y-PSZ had a higher fracture load (p < 0.0001). CONCLUSIONS Cement type affected fracture load of crowns but surface treatment did not. The 0.8 mm uniform thick crowns tested benefited from using resin cement regardless of type of ceramic material. Crowns fabricated from 5Y-Z may be particle-abraded if luted with resin cement.
Collapse
Affiliation(s)
- Nathaniel C Lawson
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Carlos A Jurado
- Department of Restorative Dentistry, Oregon Health & Science University, Portland, OR
| | - Chan-Te Huang
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL.,Department of Dentistry, Chang Gung Memorial Hospital at Keelung, Taiwan
| | | | - John O Burgess
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Perng-Ru Liu
- Department of Restorative Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Keith E Kinderknecht
- Department of Restorative Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Chee Paul Lin
- Center for Clinical and Translational Science, Birmingham, AL
| | - Daniel A Givan
- Department of Restorative Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| |
Collapse
|
18
|
Schmitt de Andrade G, Diniz V, Datte CE, Pereira GKR, Venturini AB, Campos TMB, Amaral M, Bottino MA, Valandro LF, Marques de Melo R. Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2019; 95:172-179. [PMID: 31009901 DOI: 10.1016/j.jmbbm.2019.04.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 04/02/2019] [Accepted: 04/05/2019] [Indexed: 10/27/2022]
Abstract
This study evaluated the effect of the CAD/CAM burs experience (newer vs older as consequence of the milling sequence) on fatigue failure load (FFL), number of cycles for failure (CFF), and survival rates of lithium disilicate glass-ceramic simplified restorations adhesively cemented to a dentin analogue substrate. Three sets of CAD/CAM burs were used to mill disc-shaped ceramic specimens (1 bur set - 18 milled discs with 10 mm diameter and 1.5 mm thickness), considering the bur experience as a result of the milling sequence to compose the study groups: G1-6 - discs obtained from the 1st to 6th milling of each bur set; G7-12 - specimens from the 7th to 12th milling; G13-18 - discs from the 13th to 18th. Discs of dentin analogue (G10, 10 mm diameter and 2.0 mm thickness) were made to serve as substrate (base material) and randomly assigned into pairs with the respective ceramic discs. Then, the ceramic discs were adhesively cemented onto the dentin analogue substrate, composing a three-layer specimen that mimics a monolithic restoration of a posterior tooth. Specimens were tested under stepwise fatigue approach: frequency = 20 Hz, 5000 cycles at maximum load of 400 N to accommodate the testing assembly, followed by incremental steps of 200 N with initial load ranging from 10 to 1000 N, to a maximum of 20,000 cycles/each step, until the occurrence of failure (radial crack). FFL and CFF were recorded at the end of the testing and subjected to statistical analysis. Supplementary roughness analysis of the milled surface was performed (n = 18) using a contact profilometer. Residual stress after milling and acid etching were accessed via X-ray Diffractometry analysis. FFL and CFF were not affected by increase on bur experience (no statistical differences among groups), despite that, it affected both Ra and Rz parameters (G1-6 had the smoothest surface). The residual stress concentration was negligible (milling did not induce residual stress concentration). It is concluded that the fatigue behavior of adhesively cemented lithium-disilicate glass-ceramic restorations was not influenced by CAD/CAM bur experience (newer vs older as consequence of the milling sequence), and so the residual stress concentration induced by milling was negligible.
Collapse
Affiliation(s)
- Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp) - Institute of Science and Technology, São José dos Campos, Brazil.
| | - Vandeberg Diniz
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp) - Institute of Science and Technology, São José dos Campos, Brazil.
| | - Carlos Eduardo Datte
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp) - Institute of Science and Technology, São José dos Campos, Brazil.
| | | | - Andressa Borin Venturini
- Oral Science, Prosthodontics Unit, Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | | | - Marina Amaral
- Department of Dentistry (Prosthetic Dentistry), University of Taubaté (UNITAU), Taubaté, Brazil.
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp) - Institute of Science and Technology, São José dos Campos, Brazil.
| | - Luiz Felipe Valandro
- Oral Science, Prosthodontics Unit, Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp) - Institute of Science and Technology, São José dos Campos, Brazil.
| |
Collapse
|
19
|
Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: Fatigue failure load, number of cycles for failure, survival rates, and stress distribution. J Mech Behav Biomed Mater 2019; 91:122-130. [DOI: 10.1016/j.jmbbm.2018.12.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 12/09/2018] [Accepted: 12/12/2018] [Indexed: 11/21/2022]
|
20
|
Zucuni CP, Venturini AB, Prochnow C, Rocha Pereira GK, Valandro LF. Load-bearing capacity under fatigue and survival rates of adhesively cemented yttrium-stabilized zirconia polycrystal monolithic simplified restorations. J Mech Behav Biomed Mater 2019; 90:673-680. [DOI: 10.1016/j.jmbbm.2018.11.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 11/08/2018] [Accepted: 11/10/2018] [Indexed: 02/04/2023]
|