1
|
Ceddia M, Romasco T, De Bortoli N, Mello BF, Piattelli A, Mijiritsky E, Di Pietro N, Trentadue B. Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5680. [PMID: 39685119 DOI: 10.3390/ma17235680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Revised: 11/09/2024] [Accepted: 11/13/2024] [Indexed: 12/18/2024]
Abstract
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30° inclined abutment (IA) and another positioned at a 30° angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
Collapse
Affiliation(s)
- Mario Ceddia
- Department of Mechanics, Mathematics and Management, Politecnico di Bari University, 70125 Bari, Italy
| | - Tea Romasco
- Department of Medical, Oral and Biotechnological Sciences, "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy
- Center for Advanced Studies and Technologies (CAST), "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy
| | - Nilton De Bortoli
- Department of Oral Implantology, Associação Paulista dos Cirurgiões Dentistas-APCD, São Bernardo do Campo 02011-000, Brazil
| | - Bruno Freitas Mello
- Department of Periodontics and Implant Dentistry, University of Vale do Itajaí, Itajaí 88302-901, Brazil
| | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy
- Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain
| | - Eitan Mijiritsky
- Department of Head and Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, School of Medicine, Tel-Aviv University, Tel Aviv 64239, Israel
- Goldschleger School of Dental Medicine, Faculty of Medicine, Tel-Aviv University, Tel Aviv 39040, Israel
| | - Natalia Di Pietro
- Department of Medical, Oral and Biotechnological Sciences, "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy
- Center for Advanced Studies and Technologies (CAST), "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy
| | - Bartolomeo Trentadue
- Department of Mechanics, Mathematics and Management, Politecnico di Bari University, 70125 Bari, Italy
| |
Collapse
|
2
|
Chmielewski M, Dąbrowski W, Ordyniec-Kwaśnica I. The Fracture Resistance Comparison between Titanium and Zirconia Implant Abutments with and without Ageing: Systematic Review and Meta-Analysis. Dent J (Basel) 2024; 12:274. [PMID: 39329840 PMCID: PMC11431843 DOI: 10.3390/dj12090274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/18/2024] [Accepted: 08/20/2024] [Indexed: 09/28/2024] Open
Abstract
Implant abutments are essential components of implant prosthetic restorations. The golden standard for abutment material is titanium; however, due to its properties, the esthetic result can be compromised. The most popular esthetic material alternatives are one- and two-piece zirconia. The study aimed to answer the questions of whether zirconia abutments can be used interchangeably with titanium in both anterior and posterior regions and how aging of the abutment affects durability. For this study, an electronic search of MEDLINE (PubMed) and Scopus (Embase) was conducted. The PRISMA guidelines were followed, and a systematic review was registered with PROSPERO. The search revealed 4031 results, of which 17 studies were selected. The strongest material for abutments is titanium, closely followed by two-piece zirconia. One-piece zirconia abutments were the weakest. The cyclic loading above 1,000,000 cycles decreased the fracture resistance of the abutments. Differences in implant diameter, angulation, and restoration affected the fracture strength of all compared materials. The main mode of failure for titanium abutments was screw bending or screw fracture. One-piece zirconia most often presented catastrophic failure with internal hexagon fracture below the implant neck. Two-piece zirconia exhibits a combination of failure modes. Two-piece zirconia abutments may be suitable for use in the posterior region, given their comparable fracture resistance to titanium abutments. Despite the fact that one-piece zirconia is capable of withstanding forces that exceed those exerted during mastication, it is recommended that it be employed primarily in the anterior dentition due to its propensity for unfavorable failure modes.
Collapse
Affiliation(s)
| | - Wojciech Dąbrowski
- Department of Dental Prosthetics, Faculty of Dentistry, Medical University of Gdansk, 80-210 Gdansk, Poland
| | - Iwona Ordyniec-Kwaśnica
- Department of Dental Prosthetics, Faculty of Dentistry, Medical University of Gdansk, 80-210 Gdansk, Poland
| |
Collapse
|
3
|
Yağır MO, Şen Ş, Şen U. Examination of Various Abutment Designs Behavior Depending on Load Using Finite Element Analysis. Biomimetics (Basel) 2024; 9:498. [PMID: 39194477 DOI: 10.3390/biomimetics9080498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Revised: 07/30/2024] [Accepted: 08/13/2024] [Indexed: 08/29/2024] Open
Abstract
Studies on dental implant abutments' geometric design and material selection offer significant innovations and results. These studies aim to improve the abutments' functionality and aesthetic performance, minimize microcavities' formation, and ensure implant-supported prostheses' longevity. For example, CAD-CAM fabricated custom abutments have been found to produce a better marginal fit and fewer microgaps than standard abutments. In an in vitro study, transepithelial abutments offered lower microgap values than titanium-based abutments and provided a better fit at the implant-abutment interface. It is known that studies to improve mechanical and biological performance with Polyether Ether Ketone (PEEK) material have been addressed. New materials such as PEEK and zirconia have offered significant advantages in biocompatibility and aesthetics. Along with those studies, different abutment designs are also important. Abutment geometry is optimized to improve stress distribution and minimize peri-implant bone loss. In implant and abutment connections with different angles, mechanical life performances may vary depending on static and dynamic load. These studies emphasize the importance of material research on different types of connections to improve dental implants' durability, homogeneous load distribution, and reliability. The abutment parts used in implant treatment are insufficient to distribute the load homogeneously against chewing pressure due to their materials and geometry. Non-uniform load distribution damages the abutment and the prosthetic crown, accelerating the wear process. This study aimed to create different abutment designs to improve dental implants' biomechanical performance and longevity. This study aimed to increase the mechanical durability of the implant-abutment connection by reducing stress concentrations in response to masticatory compression on the abutment in different directions and forces and to guarantee the long-term success of the implant system by providing a more homogeneous stress distribution. It aimed to apply different forces in the axial direction to these models in a simulation environment and to calculate and compare the deformation and stress load distribution. As a method, three-dimensional models of the parts used in implant treatments and forming the implant system were designed. Different abutment designs were created with these models. Taking the current material values used in implant treatments as a reference, finite element analysis (FEA) was performed by applying different axial loads to each implant system model in the ANSYS software (version 24.1). Comparative analysis graphs were prepared and interpreted for the stress values obtained after the applied load. This study evaluated the mechanical performance of different abutment models (A, B, C, D, and E) under a 100 N load using the Kruskal-Wallis test. The Kruskal-Wallis test showed significant differences between the groups (p < 0.001). The greatest difference was observed between models E and A (q' = 6.215), with a significant difference also found between models C and A (q' = 3.219, p < 0.005). Regarding stress values, the highest stress on the abutment was observed in Model B (97.4 MPa), while the lowest stress was observed in Model E (9.6 MPa). The crown exhibited the highest stress in Model B (22.7 MPa) and the lowest in Model E (17.3 MPa). The implant stress was highest in Model C (14.8 MPa) and lowest in Model B (11.3 MPa). The stress values for the cortical bone and cancellous bone were quite similar across the models, showing no significant differences. These findings indicate that the abutment design and material selection significantly impact mechanical performance. Among the implant systems created with five different abutment models, in which the existing abutment geometry was also compared, homogeneous and axial distribution of the load on the abutment was achieved, especially with viscoelastic and surface area increased abutment designs. Clinically, the inadequacy and limited mounting surface or geometry of the abutments used in today's implant treatment applications have led to different design searches. It was concluded that the designs in this study, which are considered alternatives to existing abutment models, contribute positively to the mechanical life of the abutment material, considering the von Mises stresses and directions. This study brings a new perspective to today's practices and offers an alternative to treatment practices.
Collapse
Affiliation(s)
- Mehmet Onur Yağır
- Electronics and Automation Program, Adapazarı Vocational School, Sakarya University, 54050 Sakarya, Turkey
- Dental Implant Design and Application Lab, Sakarya University, 54050 Sakarya, Turkey
| | - Şaduman Şen
- Metallurgical Materials Engineering, Faculty of Engineering, Sakarya University, 54050 Sakarya, Turkey
| | - Uğur Şen
- Metallurgical Materials Engineering, Faculty of Engineering, Sakarya University, 54050 Sakarya, Turkey
| |
Collapse
|
4
|
de Oliveira Rigotti RL, Tardelli JDC, Dos Reis AC, da Valente MLC. Influence of dental implant/mini-implant design on stress distribution in overdentures: a systematic review. Oral Maxillofac Surg 2024; 28:515-527. [PMID: 37665393 DOI: 10.1007/s10006-023-01177-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 08/18/2023] [Indexed: 09/05/2023]
Abstract
PURPOSE Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?". METHODS This systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters. RESULTS Sixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction). CONCLUSION It can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.
Collapse
Affiliation(s)
- Renan Leonardi de Oliveira Rigotti
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Juliana Dias Corpa Tardelli
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil
| | - Mariana Lima Costa da Valente
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. Do Café, S/N, Ribeirão Preto, SP, 14040-904, Brazil.
| |
Collapse
|
5
|
Riberti N, D’Amico E, Pierfelice TV, Furlani M, Giuliani A, Piattelli A, Iezzi G, Comuzzi L. Case Report of a Dental Implant with Conometric Abutment-Prosthetic Cap Connection: Advanced High-Resolution Imaging and Peri-Implant Connective Tissue Performance. Clin Pract 2024; 14:556-569. [PMID: 38666801 PMCID: PMC11049280 DOI: 10.3390/clinpract14020043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/19/2024] [Accepted: 03/25/2024] [Indexed: 04/28/2024] Open
Abstract
Background: In recent years, the use of conometric systems to connect dental implant abutments and prosthetic caps has been advocated because they seem to eliminate the side effects reported when using screw- and cement-connected prosthetic restorations. Objectives: The present case study is focused on conometric connection characterization and its performance in terms of the microarchitecture of peri-implant soft tissues by using a cross-linked approach based on optical microscopy and three-dimensional imaging. Methods: Two dental implants were characterized using micro-CT and another identical one was implanted into a patient; the latter was retrieved 45 days later due to changes in prosthetic needs. Afterward, the peri-implant soft tissues were investigated using synchrotron-based phase contrast imaging, histology, and polarized light microscopy. Results: Micro-CT analysis showed perfect adhesion between the abutment and prosthetic cap; histology and polarized light microscopy showed that connective tissue was richly present around the abutment retrieved from the patient. Moreover, the quantitative evaluation of connective tissues using synchrotron imaging, supported by artificial intelligence, revealed that this tissue was rich in mature collagen, with longitudinal and transverse collagen bundles intertwined. The number and connectivity of transverse bundles were consistently greater than those of the longitudinal bundles. Conclusion: It was found that the peri-implant soft tissue was already mature and well organized after only 45 days of implantation, supporting the hypothesis that conometric connections contribute to the significant stabilization of peri-implant soft tissues.
Collapse
Affiliation(s)
- Nicole Riberti
- Neuroscience, Imaging and Clinical Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Emira D’Amico
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Tania Vanessa Pierfelice
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Michele Furlani
- Odontostomatologic and Specialized Clinical Sciences Department, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;
| | - Alessandra Giuliani
- Odontostomatologic and Specialized Clinical Sciences Department, Polytechnic University of Marche, Via Brecce Bianche, 60131 Ancona, Italy;
| | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University for Health Sciences (Unicamillus), 00131 Rome, Italy;
| | - Giovanna Iezzi
- Medical, Oral and Biotechnological Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy; (E.D.); (T.V.P.); (G.I.)
| | - Luca Comuzzi
- Independent Researcher, Via Raffaello 36/a, 31020 San Vendemiano (TV), Italy;
| |
Collapse
|
6
|
Goyeneche VP, Cortellari GC, Rodriguez F, De Aza PN, Maria da Costa E, Scarano A, Júnior NDB, Gehrke SA. Does the index in Morse taper connection affect the abutment stability? An in vitro experimental study. PLoS One 2024; 19:e0298462. [PMID: 38457413 PMCID: PMC10923422 DOI: 10.1371/journal.pone.0298462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 01/24/2024] [Indexed: 03/10/2024] Open
Abstract
The present study compared three different implant and abutment sets of type Morse taper (MT) connection, with- and without-index, were analyzed regarding their mechanical behavior without and with cyclic load application simulating the masticatory function. Ninety implant and abutment (IA) sets were used in the present study, divided into three groups (n = 30 samples per group): Group A, Ideale solid straight abutment (one piece) without index; Group B, Ideale abutment with an angle of 30-degree (two pieces) without index; Group C, Ideale abutment with an angle of 30-degree (two pieces) with index. The abutment stability quotient (ASQ) values, detorque value and rotation angle were measured before and after the cycling load. Twenty IA sets of each group were submitted to mechanical load at 360,000 cycles. The ASQ without load were 64.7 ± 2.49 for the group A, 60.2 ± 2.64 for the group B, 54.4 ± 3.27 for the group C; With load were 66.1 ± 5.20 for the group A, 58.5 ± 6.14 for the group B, 58.9 ± 2.99 for the group C. Detorque values were lower in groups B and C compared to group A (p < 0.05). In conclusion, the presence of the index did not influence the stability values. However, solid straight abutments (group A) showed higher values of stability compared to groups of angled abutments (groups B and C).
Collapse
Affiliation(s)
| | | | | | - Piedad N. De Aza
- Departament of Bioingenieria, Universidad Miguel Hernández de Elche, Alicante, Spain
| | - Eleani Maria da Costa
- Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Antonio Scarano
- Departament of Implantology, Bioface/PgO/UCAM, Montevideo, Uruguay
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Chieti CH, Italy
| | | | - Sergio Alexandre Gehrke
- Departament of Implantology, Bioface/PgO/UCAM, Montevideo, Uruguay
- Departament of Bioingenieria, Universidad Miguel Hernández de Elche, Alicante, Spain
- Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
- Department of Biotechnology, Universidad Católica de Murcia (UCAM), Murcia, Spain
| |
Collapse
|
7
|
Yao KT, Chang TY, Huang GJ, Fang HW, Wang DH, Hsu ML. Survival of Four Conical Implant Abutment Connections After Removal of the Abutment Screw and Simulated Cyclic Loading: An In Vitro Comparative Study. J ORAL IMPLANTOL 2023; 49:393-400. [PMID: 37527179 DOI: 10.1563/aaid-joi-d-22-00037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 04/22/2023] [Accepted: 05/29/2023] [Indexed: 08/03/2023]
Abstract
This in vitro study evaluated the mechanical behavior of different conical connection implant systems after abutment screw withdrawal. Four conical connection systems were selected based on different conical half-angles: Ankylos (5.7°), Cowell (7.0°), Straumann (7.5°), and Astra (11.0°). In each system, 5 implants and abutments were used (n = 5). According to the recommended value, each abutment screw was torqued to settle the abutment and then withdrawn through a predesigned hole of the cemented crown. The retentiveness of the abutment was evaluated by the following mechanical testing. All specimens were subjected to cyclic loading of 20-200 N, 30°, and 4-mm off-axis to the implant axis, for 106 cycles. The pullout forces and axial displacements of the abutments were measured. The data of the Cowell system was obtained from our previous work. All groups other than Astra group, in which abutment loosened after abutment screw withdrawal, passed the cyclic loading test. Straumann group demonstrated a significantly lower pullout force (27.4 ± 21.1 N) than Ankylos (160.1 ± 41.4 N) and Cowell (183.7 ± 30.5 N) groups. All groups showed abutment rebound after screw withdrawal except Straumann group. In addition, Ankylos, Cowell, and Straumann groups demonstrated axial displacement after cyclic loading. In terms of the retentiveness of the abutment after abutment screw withdrawal examined in this study, Ankylos and Cowell groups had much higher retentiveness than Straumann group, while Astra group had none. Conical angle could be a key design parameter to make abutment screw withdrawal after conical abutment settlement feasible, but more studies must be conducted for clinical application.
Collapse
Affiliation(s)
- Kuang-Ta Yao
- School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Tsai-Yu Chang
- School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Guan-Jhong Huang
- School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology & Institute of Chemical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - Ding-Han Wang
- School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Ming-Lun Hsu
- School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
8
|
Körtvélyessy G, Szabó ÁL, Pelsőczi-Kovács I, Tarjányi T, Tóth Z, Kárpáti K, Matusovits D, Hangyási BD, Baráth Z. Different Conical Angle Connection of Implant and Abutment Behavior: A Static and Dynamic Load Test and Finite Element Analysis Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1988. [PMID: 36903102 PMCID: PMC10004464 DOI: 10.3390/ma16051988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/23/2023] [Accepted: 02/26/2023] [Indexed: 06/18/2023]
Abstract
Dental implants are artificial dental roots anchoring prosthetic restorations to replace natural teeth. Dental implant systems may have different tapered conical connections. Our research focused on the mechanical examination of implant-superstructure connections. Thirty-five samples with 5 different cone angles (24°, 35°, 55°, 75°, and 90°) were tested for static and dynamic loads, carried out by a mechanical fatigue testing machine. Fixing screws were fixed with a torque of 35 Ncm before measurements. For static loading, samples were loaded with a force of 500 N in 20 s. For dynamic loading, the samples were loaded for 15,000 cycles with a force of 250 ± 150 N. In both cases, the compression resulting from load and reverse torque was examined. At the highest compression load of the static tests, a significant difference (p = 0.021) was found for each cone angle group. Following dynamic loading, significant differences (p < 0.001) for the reverse torques of the fixing screw were also shown. Static and dynamic results showed a similar trend: under the same loading conditions, changing the cone angle-which determines the relationship between the implant and the abutment-had led to significant differences in the loosening of the fixing screw. In conclusion, the greater the angle of the implant-superstructure connection, the smaller the screw loosening due to loading, which may have considerable effects on the long-term, safe operation of the dental prosthesis.
Collapse
Affiliation(s)
- Győző Körtvélyessy
- Department of Oral Biology and Experimental Dental Research, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Árpád László Szabó
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - István Pelsőczi-Kovács
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Tamás Tarjányi
- Department of Oral Biology and Experimental Dental Research, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Zsolt Tóth
- Department of Medical Physics and Informatics, Albert Szent-Györgyi Medical School, Faculty of Science and Informatics, University of Szeged, Korányi fasor 9, H-6720 Szeged, Hungary
| | - Krisztina Kárpáti
- Department of Orthodontics and Pediatric Dentistry, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Danica Matusovits
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Botond Dávid Hangyási
- Department of Periodontology, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| | - Zoltán Baráth
- Department of Prosthodontics, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64-66, H-6720 Szeged, Hungary
| |
Collapse
|
9
|
Ožiūnas R, Sakalauskienė J, Staišiūnas L, Žekonis G, Žilinskas J, Janužis G. Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading. J Adv Prosthodont 2023; 15:33-43. [PMID: 36908752 PMCID: PMC9992696 DOI: 10.4047/jap.2023.15.1.33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 11/23/2022] [Accepted: 12/01/2022] [Indexed: 03/06/2023] Open
Abstract
PURPOSE This study investigated the physical and mechanical changes in the titanium base of three different hybrid abutment materials after cyclic loading by estimating the post-load reverse torque value (RTV), compressive side fulcrum wear pattern of titanium base, and surface roughness. MATERIALS AND METHODS A total of 24 dental implants were divided into three groups (n = 8 each): Group Z, LD, and P used zirconia, lithium disilicate, and polyetheretherketone, respectively, for hybrid abutment fabrication. RTV was evaluated after cyclic loading with 50 N for 1.2 × 106 chewing cycles. The compressive sides of the titanium bases were analyzed using a scanning electron microscope, and the roughness of the affected areas was measured using an optical profilometer after loading. Datasets were analyzed using Kruskal-Wallis test followed by Mann-Whitney tests with the Bonferroni correction (α = .05). RESULTS Twenty-three samples passed the test; one LD sample fractured after 770,474 cycles. Post-load RTV varied significantly depending on the hybrid-abutment material (P = .020). Group P had a significantly higher median of post-load RTVs than group Z (16.5 and 14.3 Ncm, respectively). Groups LD and P showed minor signs of wear, and group Z showed a more pronounced wear pattern. While evaluating compressive side affected area roughness of titanium bases, lower medians were shown in group LD (Ra 0.16 and Rq 0.22 µm) and group P (Ra 0.16 and Rq 0.23 µm) than in group Z (Ra 0.26 and Rq 0.34 µm); significant differences were found only among the unaffected surface and group Z. CONCLUSION The hybrid abutment material influences the post-load RTV. Group Z had a more pronounced wear pattern on the compressive side of titanium base; however, the surface roughness was not statistically different among the hybrid-abutment groups.
Collapse
Affiliation(s)
- Rimantas Ožiūnas
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Jurgina Sakalauskienė
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | | | - Gediminas Žekonis
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Juozas Žilinskas
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Gintaras Janužis
- Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
10
|
Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant–Abutment Connections. Int J Mol Sci 2022; 23:ijms23148031. [PMID: 35887378 PMCID: PMC9322952 DOI: 10.3390/ijms23148031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 07/17/2022] [Accepted: 07/19/2022] [Indexed: 12/10/2022] Open
Abstract
The presence of a microgap along an implant–abutment connection (IAC) is considered the main disadvantage of two-piece implant systems. Its existence may lead to mechanical and biological complications. Different IAC designs have been developed to minimise microleakage through the microgap and to increase the stability of prosthodontic abutments. Furthermore, different sealing materials have appeared on the market to seal the gap at the IAC. The purpose of this study was to evaluate the antimicrobial efficacy and permeability of different materials designed to seal the microgap, and their behaviour in conical and straight types of internal IACs. One hundred dental implants with original prosthodontic abutments were divided into two groups of fifty implants according to the type of IAC. Three different sealing materials (GapSeal, Flow.sil, and Oxysafe gel) were applied in the test subgroups. The contamination of implant–abutment assemblies was performed by a joint suspension containing Candida albicans and Staphylococcus aureus. It was concluded that the IAC type had no significant influence on microleakage regarding microbial infection. No significant difference was found between the various sealing agents. Only one sealing agent (GapSeal) was found to significantly prevent microleakage. A complete hermetic seal was not achieved with any of the sealing agents tested in this study.
Collapse
|
11
|
D’Ercole S, Dotta TC, Farani MR, Etemadi N, Iezzi G, Comuzzi L, Piattelli A, Petrini M. Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study. Bioengineering (Basel) 2022; 9:277. [PMID: 35877328 PMCID: PMC9311948 DOI: 10.3390/bioengineering9070277] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 06/18/2022] [Accepted: 06/22/2022] [Indexed: 11/28/2022] Open
Abstract
The objective of this study is to evaluate, in vitro, the microleakage of bacteria of 3 different implant connections for a period of 14 days. 60 dental implants (AoN) (n = 20) were distinguished into three groups, accordingly to the type of connection: External Hexagon (EH), Internal Hexagon (IH), and Cone Morse (CM) connection. All implants were inserted and fixed on sterile special vinyl support. Ten fixtures for each group were inoculated in the internal platform with 1.0 μL of Streptococcus oralis (SO) and the other ten with the same amount of Pseudomonas aeruginosa (PA). The penetration of bacterial suspension into the surrounding solution was determined by the observation of the turbidity of the broth. Five implants for each sub-group were randomly observed at SEM, to verify the correct fitting of the abutments. Considering the total of the samples analyzed, CM showed significantly lower bacterial contamination, with respect to IH. In particular, bacterial contamination was found in 45%, 55%, and 20% of EH, IH, and CM, respectively. Analyzing results for the type of inoculated bacteria, P. aeruginosa showed a higher ability to contaminate all the connections, with respect to S. oralis.
Collapse
Affiliation(s)
- Simonetta D’Ercole
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy; (S.D.); (G.I.)
| | - Tatiane Cristina Dotta
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo 05508-070, Brazil;
| | - Marzieh Ramezani Farani
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran 1416634793, Iran;
| | - Niloofar Etemadi
- Department of Materials Engineering-Tissue Engineering Najafabad Branch, Islamic Azad University, Isfhan 6134937333, Iran;
| | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy; (S.D.); (G.I.)
| | - Luca Comuzzi
- Private Practice, San Vendemiano-Conegliano, 31020 Treviso, Italy;
| | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University for Health Sciences (Unicamillus), 00131 Rome, Italy;
- Fondazione Villa Serena per la Ricerca, 65013 Città Sant’Angelo, Italy
- Casa di Cura Villa Serena, 65013 Città Saint’Angelo, Italy
| | - Morena Petrini
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy; (S.D.); (G.I.)
| |
Collapse
|
12
|
Mohamed AMA, Askar MG, El Homossany MEMB. Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study. BMC Oral Health 2022; 22:196. [PMID: 35599323 PMCID: PMC9125928 DOI: 10.1186/s12903-022-02228-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 05/11/2022] [Indexed: 11/10/2022] Open
Abstract
Background Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. Methods Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. Results The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. Conclusion The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme.
Collapse
|
13
|
Altuwaijri SM, Alotaibi HN, Alnassar TM. The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload. J Adv Prosthodont 2022; 14:22-31. [PMID: 35284054 PMCID: PMC8891687 DOI: 10.4047/jap.2022.14.1.22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/29/2021] [Accepted: 02/15/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The purpose of this study was to investigate the misfit and screw preload at the implant abutment connection of implant supported fixed dental prosthesis with cantilever (ICFDP) manufactured using different digital manufacturing techniques and to compare the screw preload before and after cyclic loading. MATERIALS AND METHODS Mandibular jaw model with four intra-foraminal implants was scanned using digital scanner. Stereolithography file was used to design a framework with nonengaging (NE) abutments and 10 mm cantilever distal to one terminal implant. Five frameworks were constructed using combined digital-conventional techniques (CAD-cast), and five frameworks were constructed using three-dimensional printing (3DP). Additional CAD-cast framework was constructed in a way that ensures passive fit (PF) to use as control. Scanning electron microscope (SEM) measured the implant abutment connection misfit. Sixty screws were used on the corresponding frameworks. Screws were torqued and pre-cyclic loading reverse torque value (RTV) was recorded. Frameworks were subjected to 200,000 loading cycles with a loading point 9 mm from the center of terminal implants adjacent to the cantilever and post-cyclic loading RTVs were recorded. RESULTS Microscopic readings showed significant differences between frameworks. PF demonstrated the lowest measurements of 16.04 (2.6) µm while CAD-cast demonstrated the highest measurements of 29.2 (3.1) µm. In all groups, RTVs were significantly lower than the applied torque. Post-cyclic loading RTV was significantly lower than pre-cyclic loading RTV in PF and 3DP frameworks. Differences in RTVs between the three manufacturing techniques were insignificant. CONCLUSION Although CAD-cast and three-dimensionally printed (3DP) both produce frameworks with clinically acceptable misfit, 3DP might not be the technique of choice for maintaining screw’s preload stability under an aggressive loading situation.
Collapse
Affiliation(s)
- Shahad Mohammmed Altuwaijri
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
- Department of Prosthetic Dental Sciences, College of Dentistry, Almajmaah University, Almajmaah, Kingdom of Saudi Arabia
| | - Hanan Nejer Alotaibi
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Talal Mughaileth Alnassar
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
14
|
Sun F, Lv LT, Cheng W, Zhang JL, Ba DC, Song GQ, Lin Z. Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5542. [PMID: 34639935 PMCID: PMC8509834 DOI: 10.3390/ma14195542] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 09/16/2021] [Accepted: 09/19/2021] [Indexed: 11/16/2022]
Abstract
Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Zeng Lin
- Key Laboratory of Implant Device and Interface Science of Liaoning Province, School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China; (F.S.); (L.-T.L.); (W.C.); (J.-L.Z.); (D.-C.B.); (G.-Q.S.)
| |
Collapse
|
15
|
Effects of tightening torque on screw stress and formation of implant-abutment microgaps: A finite element analysis. J Prosthet Dent 2021; 127:882-889. [PMID: 33472752 DOI: 10.1016/j.prosdent.2020.11.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 11/23/2020] [Accepted: 11/23/2020] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM The mechanical behavior of the conical connection implant with different torque levels requires evaluation. PURPOSE The purpose of the finite element analysis study was to investigate the impact of abutment screw torque on the formation of microgaps at the implant-to-abutment interface of a conical connection under oblique loading. This is important because it is thought that bacteria can invade the internal implant space through the abutment-implant microgaps, causing peri-implantitis. MATERIAL AND METHODS Three-dimensional finite element analyses of the conical implant-abutment connection were performed by using screw torques of 20 Ncm and 30 Ncm. Oblique loads from 10 N to 280 N were applied to the prosthesis placed on the implant. The maximum von Mises stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated. RESULTS The stresses in the abutment screw under oblique loading had limited sensitivity to the screw torque. However, the residual stress in the screw with a 30-Ncm torque was 35% higher than that with a 20-Ncm torque in the absence of an external load. The area in contact at the implant-to-abutment interface decreased with increasing load for both torque values. The critical load for bridging the internal implant space was 160 N for a screw torque of 20 Ncm and 220 N for a screw torque of 30 Ncm. The maximum gap size was approximately 470 μm with all the loads. CONCLUSIONS Increasing the screw torque can reduce the formation of microgaps at the implant-to-abutment interface. However, this will result in higher mean stress in the abutment screw, which may reduce its fatigue life and consequently that of the prosthesis. Further research is needed to evaluate the relationship between the abutment screw torque and microleakage in implant-supported restorations.
Collapse
|
16
|
Gao J, Min J, Chen X, Yu P, Tan X, Zhang Q, Yu H. Effects of two fretting damage modes on the dental implant–abutment interface and the generation of metal wear debris: An in vitro study. FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES 2020. [DOI: 10.1111/ffe.13399] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Jing Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Jie Min
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Xin Chen
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Ping Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Xin Tan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Qianqian Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology Sichuan University Chengdu 610041 China
| |
Collapse
|
17
|
Yao KT, Chang TY, Fang HW, Huang CH, Wang DH, Hsu ML. Abutment screw withdrawal after conical abutment settlement: A pilot study. Clin Oral Implants Res 2019; 31:144-152. [PMID: 31647133 DOI: 10.1111/clr.13550] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 10/11/2019] [Accepted: 10/19/2019] [Indexed: 12/01/2022]
Abstract
OBJECTIVE This study investigated the effects of abutment screw withdrawal after conical abutment settlement on the stability of the implant-abutment connection. MATERIALS AND METHODS Twenty implants of a conical connection system were used. Two two-piece abutment designs were used: cone only (n = 10; NI) and cone plus octagonal index design (n = 10; I); for each design, five samples were used with (S) and without (NS) abutment screw withdrawal before a cyclic test. Finally, four groups, namely Gr S(NI), Gr S(I), Gr NS(NI), and Gr NS(I), were included. The cyclic test included cyclic loading of 20-200 N, 30°, and 4-mm off-axis to implant axis at 10 Hz for 106 cycles, simulating a clinical time interval of 40 months. The fatigue cycles were recorded. The axial displacement of the conical abutments during abutment settlement, screw withdrawal, and cyclic loading were measured. Abutment morphology was examined through scanning electron microscopy (SEM). RESULTS Only Gr NS(NI) failed the test, indicating that without the index design and abutment screw withdrawal, and connection stability seriously deteriorated. Gr NS(I) exhibited significantly higher axial displacement into the implant after abutment settlement than did Gr NS(NI). It also exhibited continuous axial displacement into the implant after cyclic loading. SEM after cyclic testing in Gr NS(I) revealed marked burnishing on lateral edges of the index, indicating that the index design provides an antitorsional ability. CONCLUSION Although this study has few limitations, abutment screw withdrawal is feasible in this conical implant-abutment connection system with index design.
Collapse
Affiliation(s)
- Kuang-Ta Yao
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Tsai-Yu Chang
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology & Institute of Chemical Engineering, National Taipei University of Technology, Taipei, Taiwan.,Division of Medical Engineering Research, National Health Research Institutes, Miaoli, Taiwan
| | - Chang-Hung Huang
- Department of Medical Research, Mackay Memorial Hospital, New Taipei city, Taiwan
| | - Ding-Han Wang
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Ming-Lun Hsu
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
18
|
Kofron MD, Carstens M, Fu C, Wen HB. In vitro assessment of connection strength and stability of internal implant-abutment connections. Clin Biomech (Bristol, Avon) 2019; 65:92-99. [PMID: 31005695 DOI: 10.1016/j.clinbiomech.2019.03.007] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 03/01/2019] [Accepted: 03/11/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Various connections have been machined to improve the fit between the dental abutment and implant. In vivo, the instability created by imprecisely fitting components can cause soft tissue irritation and bacterial colonization of the implant system. The aim of this study was to quantify abutment stability under in vitro force applications. METHODS Abutment stability and fit were quantitatively measured after application of rotational, vertical, and horizontal forces. FINDINGS The abutment connection held by friction (Friction-Fit) was the only group to have 0° angular rotation. A significantly greater vertical force was required to pull the abutment from the implant for the Friction-Fit connection as compared to all other experimental groups. The abutment connection held by a mechanically locking friction-fit with four grooves (CrossFit) and Friction-Fit demonstrated significantly lower lateral movement as compared to all other connections. The remaining connections evaluated included two hexagon connections that rely on screw placement for abutment fit (Conical + Hex #1 and Conical + Hex #2), one connection with protruding slots to align with recessed channels inside the implant (Conical + 6 Indexing Slots), and an internal connection that allows for abutment indexing every 120° (Internal Tri-Channel). INTERPRETATION Internal connection geometry influenced the degree of abutment movement. Friction-Fit and CrossFit connections exhibited the lowest rotational and horizontal motions. Significant differences were found between Friction-Fit and CrossFit following the application of a vertical force, with the Friction-Fit requiring a significantly greater pull force to separate the abutment from the implant.
Collapse
Affiliation(s)
- Michelle D Kofron
- Biomet 3i, LLC, a Zimmer Biomet company, 4555 Riverside Drive, Palm Beach Gardens, FL, United States.
| | - Matthew Carstens
- Biomet 3i, LLC, a Zimmer Biomet company, 4555 Riverside Drive, Palm Beach Gardens, FL, United States
| | - Cong Fu
- Biomet 3i, LLC, a Zimmer Biomet company, 4555 Riverside Drive, Palm Beach Gardens, FL, United States
| | - Hai Bo Wen
- Biomet 3i, LLC, a Zimmer Biomet company, 4555 Riverside Drive, Palm Beach Gardens, FL, United States
| |
Collapse
|