Ramirez GO, Mariano CA, Carter D, Eskandari M. Visceral pleura mechanics: Characterization of human, pig, and rat lung material properties. Acta Biomater 2024:S1742-7061(24)00519-1. [PMID: 39251049 DOI: 10.1016/j.actbio.2024.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 08/13/2024] [Accepted: 09/04/2024] [Indexed: 09/11/2024]
Abstract
Pulmonary air leaks are amongst the most common complications in lung surgery. Lung sealants are applied to the organ surface and need to synchronously stretch with the visceral pleura, the layer of tissue which encompasses the lung parenchymal tissue. These adhesives are commonly tested on pig and rat lungs, but applied to human lungs. However, the unknown mechanics of human lung visceral pleura undermines the clinical translatability of such animal-tested sealants and the absence of how pig and rat lung visceral pleura compare to human tissues is necessary to address. Here we quantify the biaxial planar tensile mechanics of visceral pleura from healthy transplant-eligible and smoker human lungs for the first time, and further compare the material behaviors to pig and rat lung visceral pleura. Initial and final stiffness moduli, maximum stress, low-to-high strain transition, and stress relaxation are analyzed and compared between and within groups, further considering regional and directional dependencies. Visceral pleura tissue from all species behave isotropically, and pig and human visceral pleura exhibits regional heterogeneity (i.e. upper versus lower lobe differences). We find that pig visceral pleura exhibits similar initial stiffness moduli and regional trends compared to human visceral pleura, suggesting pig tissue may serve as a viable animal model candidate for lung sealant testing. The outcomes and mechanical characterization of these scarce tissues enables future development of biomimetic lung sealants for improved surgical applications. STATEMENT OF SIGNIFICANCE: Surgical lung sealants must synchronously deform with the underlying tissue and with each breath to minimize post-operative air leaks, which remain the most frequent complications of pulmonary intervention. These adhesives are often tested on pig and rat lungs, but applied to humans; however, the material properties of human lung visceral pleura were previously unexplored. Here, for the first time, the mechanics of human visceral pleura tissue are investigated, further contrasting rarely acquired donated lungs from healthy and smoking individuals, and additionally, comparing biaxial planar material characterizations to animal models often employed for pulmonary sealant development. This fundamental material characterization addresses key hindrances in the advancement of biomimetic sealants and evaluates the translatability of animal model experiments for clinical applications.
Collapse
Affiliation(s)
- Gustavo O Ramirez
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - David Carter
- Department of Molecular, Cell and Systems Biology, University of California, Riverside, CA, USA
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA; BREATHE Center, School of Medicine University of California, Riverside, CA, USA; Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
2
|
Nelson TM, Mariano CA, Ramirez GO, Badrou A, Quiros KAM, Shankel M, Eskandari M. Lung Mechanics: Material Characterization of Pulmonary Constituents for an Experimentally Informed Computational Pipeline. Curr Protoc 2024; 4:e70001. [PMID: 39240156 DOI: 10.1002/cpz1.70001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
The lung comprises multiple components including the parenchyma, airways, and visceral pleura, where each constituent displays specific material properties that together govern the whole organ's properties. The structural and mechanical complexity of the lung has historically undermined its comprehensive characterization, especially compared to other biological organs, such as the heart or bones. This knowledge void is particularly remarkable when considering that pulmonary disease is one of the leading causes of morbidity and mortality across the globe. Establishing the mechanical properties of the lung is central to formulating a baseline understanding of its operation, which can facilitate investigations of diseased states and how the lung will potentially respond to clinical interventions. Here, we present established and widely accepted experimental protocols for pulmonary material quantification, specifying how to extract, prepare, and test each type of lung constituent under planar biaxial tensile loading to investigate the mechanical properties, such as physiological stress-strain profiles, anisotropy, and viscoelasticity. These methods are presented across an array of commonly studied species (murine, rat, and porcine). Additionally, we highlight how such material properties may inform the construction of an inverse finite element model, which is central to implementing predictive computational tools for accurate disease diagnostics and optimized medical treatments. These presented methodologies are aimed at supporting research advancements in the field of pulmonary biomechanics and to help inaugurate future novel studies. © 2024 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: General procedures in lung biaxial testing Alternate Protocol 1: Parenchymal-specific preparation and loading procedures Alternate Protocol 2: Airway-specific preparation and loading procedures Alternate Protocol 3: Visceral pleura-specific preparation and loading procedures Basic Protocol 2: Computational analysis.
Collapse
Affiliation(s)
- Talyah M Nelson
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Gustavo O Ramirez
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Arif Badrou
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Kathrine A M Quiros
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Matthew Shankel
- Department of Mechanical Engineering, University of California, Riverside, California
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, California
- BREATHE Center, School of Medicine University of California, Riverside, California
- Department of Bioengineering, University of California, Riverside, California
| |
Collapse
|
3
|
Quiros KAM, Nelson TM, Ulu A, Dominguez EC, Biddle TA, Lo DD, Nordgren TM, Eskandari M. A Comparative Study of Ex-Vivo Murine Pulmonary Mechanics Under Positive- and Negative-Pressure Ventilation. Ann Biomed Eng 2024; 52:342-354. [PMID: 37906375 PMCID: PMC10808462 DOI: 10.1007/s10439-023-03380-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 10/03/2023] [Indexed: 11/02/2023]
Abstract
Increased ventilator use during the COVID-19 pandemic resurrected persistent questions regarding mechanical ventilation including the difference between physiological and artificial breathing induced by ventilators (i.e., positive- versus negative-pressure ventilation, PPV vs NPV). To address this controversy, we compare murine specimens subjected to PPV and NPV in ex vivo quasi-static loading and quantify pulmonary mechanics via measures of quasi-static and dynamic compliances, transpulmonary pressure, and energetics when varying inflation frequency and volume. Each investigated mechanical parameter yields instance(s) of significant variability between ventilation modes. Most notably, inflation compliance, percent relaxation, and peak pressure are found to be consistently dependent on the ventilation mode. Maximum inflation volume and frequency note varied dependencies contingent on the ventilation mode. Contradictory to limited previous clinical investigations of oxygenation and end-inspiratory measures, the mechanics-focused comprehensive findings presented here indicate lung properties are dependent on loading mode, and importantly, these dependencies differ between smaller versus larger mammalian species despite identical custom-designed PPV/NPV ventilator usage. Results indicate that past contradictory findings regarding ventilation mode comparisons in the field may be linked to the chosen animal model. Understanding the differing fundamental mechanics between PPV and NPV may provide insights for improving ventilation strategies and design to prevent associated lung injuries.
Collapse
Affiliation(s)
- K A M Quiros
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA
| | - T M Nelson
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA
| | - A Ulu
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
| | - E C Dominguez
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
| | - T A Biddle
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
| | - D D Lo
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
- Center for Health Disparities Research, University of California, Riverside, CA, USA
| | - T M Nordgren
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA.
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA.
- Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
4
|
Castaño J, Giraldo MA, Montoya Y, Montagut YJ, Palacio AF, Jiménez LD. Electropneumatic system for the simulation of the pulmonary viscoelastic effect in a mechanical ventilation scenario. Sci Rep 2023; 13:21275. [PMID: 38042871 PMCID: PMC10693622 DOI: 10.1038/s41598-023-41881-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 09/01/2023] [Indexed: 12/04/2023] Open
Abstract
The viscoelastic properties of the lung have important implications during respiratory mechanics in terms of lung movement or work of breathing, for example. However, this property has not been well characterized due to several reasons, such as the complex nature of the lung, difficulty accessing its tissues, and the lack of physical simulators that represent viscoelastic effects. This research proposes an electropneumatic system and a method to simulate the viscoelastic effect from temporary forces generated by the opposition of magnetic poles. The study was tested in a mechanical ventilation scenario with inspiratory pause, using a Hamilton-S1 mechanical ventilator (Hamilton Medical) and a simulator of the human respiratory system (SAMI-SII). The implemented system was able to simulate the stress relaxation response of a Standard Linear Solid model in the Maxwell form and showed the capacity to control elastic and viscous parameters independently. To the best of our knowledge, this is the first system incorporated into a physical lung simulator that represents the viscoelastic effect in a mechanical ventilation scenario.
Collapse
Affiliation(s)
| | | | | | | | - Andrés F Palacio
- Universidad EIA, Envigado, Colombia
- Hospital Alma Máter de Antioquia, Medellín, Colombia
| | | |
Collapse
|
5
|
Pydi YS, Nath A, Chawla A, Mukherjee S, Lalwani S, Malhotra R, Datla NV. Strain-rate-dependent material properties of human lung parenchymal tissue using inverse finite element approach. Biomech Model Mechanobiol 2023; 22:2083-2096. [PMID: 37535253 DOI: 10.1007/s10237-023-01751-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 07/09/2023] [Indexed: 08/04/2023]
Abstract
Automobile crashes and blunt trauma often lead to life-threatening thoracic injuries, especially to the lung tissues. These injuries can be simulated using finite element-based human body models that need dynamic material properties of lung tissue. The strain-rate-dependent material parameters of human parenchymal tissues were determined in this study using uniaxial quasi-static (1 mm/s) and dynamic (1.6, 3, and 5 m/s) compression tests. A bilinear material model was used to capture the nonlinear behavior of the lung tissue, which was implemented using a user-defined material in LS-DYNA. Inverse mapping using genetic algorithm-based optimization of all experimental data with the corresponding FE models yielded a set of strain-rate-dependent material parameters. The bilinear material parameters are obtained for the strain rates of 0.1, 100, 300, and 500 s-1. The estimated elastic modulus increased from 43 to 153 kPa, while the toe strain reduced from 0.39 to 0.29 when the strain rate was increased from 0.1 to 500 s-1. The optimized bilinear material properties of parenchymal tissue exhibit a piecewise linear relationship with the strain rate.
Collapse
Affiliation(s)
- Yeswanth S Pydi
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India.
| | - Atri Nath
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India
| | - Anoop Chawla
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India
| | - Sudipto Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India
| | - Sanjeev Lalwani
- Department of Forensic Science and Toxicology, All India Institute of Medical Sciences, New Delhi, India
| | - Rajesh Malhotra
- Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India
| | - Naresh V Datla
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, 110016, India
| |
Collapse
|
6
|
Sattari S, Mariano CA, Eskandari M. Pressure-volume mechanics of inflating and deflating intact whole organ porcine lungs. J Biomech 2023; 157:111696. [PMID: 37413822 DOI: 10.1016/j.jbiomech.2023.111696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 06/14/2023] [Accepted: 06/19/2023] [Indexed: 07/08/2023]
Abstract
Pressure-volume curves of the lung are classical measurements of lung function and are impacted by changes in lung structure due to disease or shifts in air-delivery volume or cycling rate. Diseased and preterm infant lungs have been found to show heterogeneous behavior which is highly frequency dependent. This breathing rate dependency has motivated the exploration of multi-frequency oscillatory ventilators to deliver volume oscillation with optimal frequencies for various portions of the lung to provide more uniform air distribution. The design of these advanced ventilators requires the examination of lung function and mechanics, and an improved understanding of the pressure-volume response of the lung. Therefore, to comprehensively analyze whole lung organ mechanics, we investigate six combinations of varying applied volumes and frequencies using ex-vivo porcine specimens and our custom-designed electromechanical breathing apparatus. Lung responses were evaluated through measurements of inflation and deflation slopes, static compliance, peak pressure and volume, as well as hysteresis, energy loss, and pressure relaxation. Generally, we observed that the lungs were stiffer when subjected to faster breathing rates and lower inflation volumes. The lungs exhibited greater inflation volume dependencies compared to frequency dependencies. This study's reported response of the lung to variations of inflation volume and breathing rate can help the optimization of conventional mechanical ventilators and inform the design of advanced ventilators. Although frequency dependency is found to be minimal in normal porcine lungs, this preliminary study lays a foundation for comparison with pathological lungs, which are known to demonstrate marked rate dependency.
Collapse
Affiliation(s)
- Samaneh Sattari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA; BREATHE Center, School of Medicine, University of California at Riverside, Riverside, CA, USA; Department of Bioengineering, University of California at Riverside, Riverside, CA, USA.
| |
Collapse
|
7
|
Mariano CA, Sattari S, Ramirez GO, Eskandari M. Effects of tissue degradation by collagenase and elastase on the biaxial mechanics of porcine airways. Respir Res 2023; 24:105. [PMID: 37031200 PMCID: PMC10082978 DOI: 10.1186/s12931-023-02376-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Accepted: 02/22/2023] [Indexed: 04/10/2023] Open
Abstract
BACKGROUND Common respiratory illnesses, such as emphysema and chronic obstructive pulmonary disease, are characterized by connective tissue damage and remodeling. Two major fibers govern the mechanics of airway tissue: elastin enables stretch and permits airway recoil, while collagen prevents overextension with stiffer properties. Collagenase and elastase degradation treatments are common avenues for contrasting the role of collagen and elastin in healthy and diseased states; while previous lung studies of collagen and elastin have analyzed parenchymal strips in animal and human specimens, none have focused on the airways to date. METHODS Specimens were extracted from the proximal and distal airways, namely the trachea, large bronchi, and small bronchi to facilitate evaluations of material heterogeneity, and subjected to biaxial planar loading in the circumferential and axial directions to assess airway anisotropy. Next, samples were subjected to collagenase and elastase enzymatic treatment and tensile tests were repeated. Airway tissue mechanical properties pre- and post-treatment were comprehensively characterized via measures of initial and ultimate moduli, strain transitions, maximum stress, hysteresis, energy loss, and viscoelasticity to gain insights regarding the specialized role of individual connective tissue fibers and network interactions. RESULTS Enzymatic treatment demonstrated an increase in airway tissue compliance throughout loading and resulted in at least a 50% decrease in maximum stress overall. Strain transition values led to significant anisotropic manifestation post-treatment, where circumferential tissues transitioned at higher strains compared to axial counterparts. Hysteresis values and energy loss decreased after enzymatic treatment, where hysteresis reduced by almost half of the untreated value. Anisotropic ratios exhibited axially led stiffness at low strains which transitioned to circumferentially led stiffness when subjected to higher strains. Viscoelastic stress relaxation was found to be greater in the circumferential direction for bronchial airway regions compared to axial counterparts. CONCLUSION Targeted fiber treatment resulted in mechanical alterations across the loading range and interactions between elastin and collagen connective tissue networks was observed. Providing novel mechanical characterization of elastase and collagenase treated airways aids our understanding of individual and interconnected fiber roles, ultimately helping to establish a foundation for constructing constitutive models to represent various states and progressions of pulmonary disease.
Collapse
Affiliation(s)
- Crystal A Mariano
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - Samaneh Sattari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - Gustavo O Ramirez
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA.
- BREATHE Center, School of Medicine, University of California at Riverside, Riverside, CA, USA.
- Department of Bioengineering, University of California at Riverside, Riverside, CA, USA.
| |
Collapse
|
8
|
Nelson TM, Quiros KAM, Dominguez EC, Ulu A, Nordgren TM, Eskandari M. Diseased and healthy murine local lung strains evaluated using digital image correlation. Sci Rep 2023; 13:4564. [PMID: 36941463 PMCID: PMC10026788 DOI: 10.1038/s41598-023-31345-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 03/09/2023] [Indexed: 03/22/2023] Open
Abstract
Tissue remodeling in pulmonary disease irreversibly alters lung functionality and impacts quality of life. Mechanical ventilation is amongst the few pulmonary interventions to aid respiration, but can be harmful or fatal, inducing excessive regional (i.e., local) lung strains. Previous studies have advanced understanding of diseased global-level lung response under ventilation, but do not adequately capture the critical local-level response. Here, we pair a custom-designed pressure-volume ventilator with new applications of digital image correlation, to directly assess regional strains in the fibrosis-induced ex-vivo mouse lung, analyzed via regions of interest. We discuss differences between diseased and healthy lung mechanics, such as distensibility, heterogeneity, anisotropy, alveolar recruitment, and rate dependencies. Notably, we compare local and global compliance between diseased and healthy states by assessing the evolution of pressure-strain and pressure-volume curves resulting from various ventilation volumes and rates. We find fibrotic lungs are less-distensible, with altered recruitment behaviors and regional strains, and exhibit disparate behaviors between local and global compliance. Moreover, these diseased characteristics show volume-dependence and rate trends. Ultimately, we demonstrate how fibrotic lungs may be particularly susceptible to damage when contrasted to the strain patterns of healthy counterparts, helping to advance understanding of how ventilator induced lung injury develops.
Collapse
Affiliation(s)
- T M Nelson
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - K A M Quiros
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - E C Dominguez
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California Riverside, Riverside, CA, USA
| | - A Ulu
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
| | - T M Nordgren
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California Riverside, Riverside, CA, USA
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA.
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA.
- Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
9
|
Sattari S, Mariano CA, Kuschner WG, Taheri H, Bates JHT, Eskandari M. Positive- and Negative-Pressure Ventilation Characterized by Local and Global Pulmonary Mechanics. Am J Respir Crit Care Med 2023; 207:577-586. [PMID: 36194677 PMCID: PMC10870900 DOI: 10.1164/rccm.202111-2480oc] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 10/04/2022] [Indexed: 11/16/2022] Open
Abstract
Rationale: There is continued debate regarding the equivalency of positive-pressure ventilation (PPV) and negative-pressure ventilation (NPV). Resolving this question is important because of the different practical ramifications of the two paradigms. Objectives: We sought to investigate the parallel between PPV and NPV and determine whether or not these two paradigms cause identical ventilation profiles by analyzing the local strain mechanics when the global tidal volume (Vt) and inflation pressure was matched. Methods: A custom-designed electromechanical apparatus was used to impose equal global loads and displacements on the same ex vivo healthy porcine lung using PPV and NPV. High-speed high-resolution cameras recorded local lung surface deformations and strains in real time, and differences between PPV and NPV global energetics, viscoelasticity, as well as local tissue distortion were assessed. Measurements and Main Results: During initial inflation, NPV exhibited significantly more bulk pressure-volume compliance than PPV, suggestive of earlier lung recruitment. NPV settings also showed reduced relaxation, hysteresis, and energy loss compared with PPV. Local strain trends were also decreased in NPV, with reduced tissue distortion trends compared with PPV, as revealed through analysis of tissue anisotropy. Conclusions: Apparently, contradictory previous studies are not mutually exclusive. Equivalent changes in transpulmonary pressures in PPV and NPV lead to the same changes in lung volume and pressures, yet local tissue strains differ between PPV and NPV. Although limited to healthy specimens and ex vivo experiments in the absence of a chest cavity, these results may explain previous reports of better oxygenation and less lung injury in NPV.
Collapse
Affiliation(s)
| | | | - Ware G. Kuschner
- Medical Service, Veterans Affairs Palo Alto Health Care System, Division of Pulmonary, Allergy & Critical Care Medicine, Stanford University, Stanford, California; and
| | | | - Jason H. T. Bates
- Department of Medicine, University of Vermont Larner College of Medicine, Burlington, Vermont
| | - Mona Eskandari
- Department of Mechanical Engineering
- BREATHE Center, School of Medicine, and
- Department of Bioengineering, University of California Riverside, Riverside, California
| |
Collapse
|
10
|
Biaxial mechanical properties of the bronchial tree: Characterization of elasticity, extensibility, and energetics, including the effect of strain rate and preconditioning. Acta Biomater 2023; 155:410-422. [PMID: 36328122 DOI: 10.1016/j.actbio.2022.10.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 10/18/2022] [Accepted: 10/21/2022] [Indexed: 11/05/2022]
Abstract
Distal airways commonly obstruct in lung disease and despite their importance, their mechanical properties are vastly underexplored. The lack of bronchial experiments restricts current airway models to either assume rigid structures, or extrapolate the material properties of the trachea to represent the small airways. Furthermore, past works are exclusively limited to uniaxial testing; investigating the multidirectional tensile loads of both the proximal and distal pulmonary airways is long overdue. Here we present comprehensive mechanical and viscoelastic properties of the porcine airway tree, including the trachea, trachealis muscle, large bronchi, and small bronchi, via measures of elasticity, extensibility, and energetics to explore regional and directional dependencies, cross-examining strain rate and preconditioning effects using planar equibiaxial tensile tests for the first time. We find bronchial regions are notably heterogeneous, where the trachea exhibits greater stiffness, energy loss, and preconditioning sensitivity than the smaller airways. Interestingly, the trachealis muscle is similar to the distal bronchi, despite being anatomically located adjacent to the proximal ring. Tissues are anisotropic and axially stiffer under initial loading, losing more energy with greater stress relaxation circumferentially. Strain rate dependency is also noted, where tissues are more energetically efficient at the faster strain rate, likely attributable to the microstructure. Findings highlight assumptions of homogeneity and isotropy are inadequate, and enable the improvement of aerosol flow and dynamic airway deformation computational predictive models. These results provide much needed fundamental material properties for future explorations contrasting healthy versus diseased pulmonary airway mechanics to better understand the relationship between structure and lung function. STATEMENT OF SIGNIFICANCE: We present comprehensive multiaxial mechanical tensile experiments of the proximal and distal airways via measures of maximum stress, initial and ultimate moduli, strain and stress transitions, hysteresis, energy loss, and stress relaxation, and further assess preconditioning and strain rate dependencies to examine the relationship between lung function and structure. The mechanical response of the bronchial tree demonstrates significant anisotropy and heterogeneity, even within the tracheal ring, and emphasizes that contrary to past studies, the behavior of the proximal airways cannot be extended to distal bronchial tree analyses. Establishing these material properties is critical to advancing our understanding of airway function and in developing accurate computational simulations to help diagnose and monitor pulmonary diseases.
Collapse
|
11
|
Nelson TM, Quiros KAM, Mariano CA, Sattari S, Ulu A, Dominguez EC, Nordgren TM, Eskandari M. Associating local strains to global pressure-volume mouse lung mechanics using digital image correlation. Physiol Rep 2022; 10:e15466. [PMID: 36207795 PMCID: PMC9547081 DOI: 10.14814/phy2.15466] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 08/22/2022] [Accepted: 08/28/2022] [Indexed: 12/24/2022] Open
Abstract
Pulmonary diseases alter lung mechanical properties, can cause loss of function, and necessitate use of mechanical ventilation, which can be detrimental. Investigations of lung tissue (local) scale mechanical properties are sparse compared to that of the whole organ (global) level, despite connections between regional strain injury and ventilation. We examine ex vivo mouse lung mechanics by investigating strain values, local compliance, tissue surface heterogeneity, and strain evolutionary behavior for various inflation rates and volumes. A custom electromechanical, pressure-volume ventilator is coupled with digital image correlation to measure regional lung strains and associate local to global mechanics by analyzing novel pressure-strain evolutionary measures. Mean strains at 5 breaths per minute (BPM) for applied volumes of 0.3, 0.5, and 0.7 ml are 5.0, 7.8, and 11.3%, respectively, and 4.7, 8.8, and 12.2% for 20 BPM. Similarly, maximum strains among all rate and volume combinations range 10.7%-22.4%. Strain values (mean, range, mode, and maximum) at peak inflation often exhibit significant volume dependencies. Additionally, select evolutionary behavior (e.g., local lung compliance quantification) and tissue heterogeneity show significant volume dependence. Rate dependencies are generally found to be insignificant; however, strain values and surface lobe heterogeneity tend to increase with increasing rates. By quantifying strain evolutionary behavior in relation to pressure-volume measures, we associate time-continuous local to global mouse lung mechanics for the first time and further examine the role of volume and rate dependency. The interplay of multiscale deformations evaluated in this work can offer insights for clinical applications, such as ventilator-induced lung injury.
Collapse
Affiliation(s)
- Talyah M. Nelson
- Department of Mechanical EngineeringUniversity of CaliforniaRiversideCaliforniaUSA
| | | | - Crystal A. Mariano
- Department of Mechanical EngineeringUniversity of CaliforniaRiversideCaliforniaUSA
| | - Samaneh Sattari
- Department of Mechanical EngineeringUniversity of CaliforniaRiversideCaliforniaUSA
| | - Arzu Ulu
- BREATHE CenterSchool of Medicine University of CaliforniaRiversideCaliforniaUSA,Division of Biomedical SciencesSchool of Medicine, University of CaliforniaRiversideCaliforniaUSA
| | - Edward C. Dominguez
- BREATHE CenterSchool of Medicine University of CaliforniaRiversideCaliforniaUSA,Division of Biomedical SciencesSchool of Medicine, University of CaliforniaRiversideCaliforniaUSA
| | - Tara M. Nordgren
- BREATHE CenterSchool of Medicine University of CaliforniaRiversideCaliforniaUSA,Division of Biomedical SciencesSchool of Medicine, University of CaliforniaRiversideCaliforniaUSA
| | - Mona Eskandari
- Department of Mechanical EngineeringUniversity of CaliforniaRiversideCaliforniaUSA,BREATHE CenterSchool of Medicine University of CaliforniaRiversideCaliforniaUSA,Department of BioengineeringUniversity of CaliforniaRiversideCaliforniaUSA
| |
Collapse
|
12
|
Kageyama S, Takeishi N, Taenaka H, Yoshida T, Wada S. Fluid dynamic assessment of positive end-expiratory pressure in a tracheostomy tube connector during respiration. Med Biol Eng Comput 2022; 60:2981-2993. [PMID: 36002620 PMCID: PMC9402408 DOI: 10.1007/s11517-022-02649-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 08/19/2022] [Indexed: 11/24/2022]
Abstract
High-flow oxygen therapy using a tracheostomy tube is a promising clinical approach to reduce the work of breathing in tracheostomized patients. Positive end-expiratory pressure (PEEP) is usually applied during oxygen inflow to improve oxygenation by preventing end-expiratory lung collapse. However, much is still unknown about the geometrical effects of PEEP, especially regarding tracheostomy tube connectors (or adapters). Quantifying the degree of end-expiratory pressure (EEP) that takes patient-specific spirometry into account would be useful in this regard, but no such framework has been established yet. Thus, a platform to assess PEEP under respiration was developed, wherein three-dimensional simulation of airflow in a tracheostomy tube connector is coupled with a lumped lung model. The numerical model successfully reflected the magnitude of EEP measured experimentally using a lung phantom. Numerical simulations were further performed to quantify the effects of geometrical parameters on PEEP, such as inlet angles and rate of stenosis in the connector. Although sharp inlet angles increased the magnitude of EEP, they cannot be expected to achieve clinically reasonable PEEP. On the other hand, geometrical constriction in the connector can potentially result in PEEP as obtained with conventional nasal cannulae.
Collapse
|
13
|
Naumann J, Koppe N, Thome UH, Laube M, Zink M. Mechanical properties of the premature lung: From tissue deformation under load to mechanosensitivity of alveolar cells. Front Bioeng Biotechnol 2022; 10:964318. [PMID: 36185437 PMCID: PMC9523442 DOI: 10.3389/fbioe.2022.964318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 08/23/2022] [Indexed: 11/16/2022] Open
Abstract
Many preterm infants require mechanical ventilation as life-saving therapy. However, ventilation-induced overpressure can result in lung diseases. Considering the lung as a viscoelastic material, positive pressure inside the lung results in increased hydrostatic pressure and tissue compression. To elucidate the effect of positive pressure on lung tissue mechanics and cell behavior, we mimic the effect of overpressure by employing an uniaxial load onto fetal and adult rat lungs with different deformation rates. Additionally, tissue expansion during tidal breathing due to a negative intrathoracic pressure was addressed by uniaxial tension. We found a hyperelastic deformation behavior of fetal tissues under compression and tension with a remarkable strain stiffening. In contrast, adult lungs exhibited a similar response only during compression. Young’s moduli were always larger during tension compared to compression, while only during compression a strong deformation-rate dependency was found. In fact, fetal lung tissue under compression showed clear viscoelastic features even for small strains. Thus, we propose that the fetal lung is much more vulnerable during inflation by mechanical ventilation compared to normal inspiration. Electrophysiological experiments with different hydrostatic pressure gradients acting on primary fetal distal lung epithelial cells revealed that the activity of the epithelial sodium channel (ENaC) and the sodium-potassium pump (Na,K-ATPase) dropped during pressures of 30 cmH2O. Thus, pressures used during mechanical ventilation might impair alveolar fluid clearance important for normal lung function.
Collapse
Affiliation(s)
- Jonas Naumann
- Research Group Biotechnology and Biomedicine, Peter-Debye-Institute for Soft Matter Physics, Leipzig University, Leipzig, Germany
| | - Nicklas Koppe
- Research Group Biotechnology and Biomedicine, Peter-Debye-Institute for Soft Matter Physics, Leipzig University, Leipzig, Germany
| | - Ulrich H. Thome
- Center for Pediatric Research Leipzig, Department of Pediatrics, Division of Neonatology, Leipzig University, Leipzig, Germany
| | - Mandy Laube
- Center for Pediatric Research Leipzig, Department of Pediatrics, Division of Neonatology, Leipzig University, Leipzig, Germany
| | - Mareike Zink
- Research Group Biotechnology and Biomedicine, Peter-Debye-Institute for Soft Matter Physics, Leipzig University, Leipzig, Germany
- *Correspondence: Mareike Zink,
| |
Collapse
|
14
|
Quiros KAM, Nelson TM, Sattari S, Mariano CA, Ulu A, Dominguez EC, Nordgren TM, Eskandari M. Mouse lung mechanical properties under varying inflation volumes and cycling frequencies. Sci Rep 2022; 12:7094. [PMID: 35501363 PMCID: PMC9059689 DOI: 10.1038/s41598-022-10417-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 03/30/2022] [Indexed: 01/23/2023] Open
Abstract
Respiratory pathologies alter the structure of the lung and impact its mechanics. Mice are widely used in the study of lung pathologies, but there is a lack of fundamental mechanical measurements assessing the interdependent effect of varying inflation volumes and cycling frequency. In this study, the mechanical properties of five male C57BL/6J mice (29-33 weeks of age) lungs were evaluated ex vivo using our custom-designed electromechanical, continuous measure ventilation apparatus. We comprehensively quantify and analyze the effect of loading volumes (0.3, 0.5, 0.7, 0.9 ml) and breathing rates (5, 10, 20 breaths per minute) on pulmonary inflation and deflation mechanical properties. We report means of static compliance between 5.4-16.1 µl/cmH2O, deflation compliance of 5.3-22.2 µl/cmH2O, percent relaxation of 21.7-39.1%, hysteresis of 1.11-7.6 ml•cmH2O, and energy loss of 39-58% for the range of four volumes and three rates tested, along with additional measures. We conclude that inflation volume was found to significantly affect hysteresis, static compliance, starting compliance, top compliance, deflation compliance, and percent relaxation, and cycling rate was found to affect only hysteresis, energy loss, percent relaxation, static compliance and deflation compliance.
Collapse
Affiliation(s)
- K A M Quiros
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - T M Nelson
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - S Sattari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - C A Mariano
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - A Ulu
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
| | - E C Dominguez
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
| | - T M Nordgren
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA.
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA.
- Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
15
|
Mariano CA, Sattari S, Quiros KAM, Nelson TM, Eskandari M. Examining lung mechanical strains as influenced by breathing volumes and rates using experimental digital image correlation. Respir Res 2022; 23:92. [PMID: 35410291 PMCID: PMC8999998 DOI: 10.1186/s12931-022-01999-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 03/18/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Mechanical ventilation is often employed to facilitate breathing in patients suffering from respiratory illnesses and disabilities. Despite the benefits, there are risks associated with ventilator-induced lung injuries and death, driving investigations for alternative ventilation techniques to improve mechanical ventilation, such as multi-oscillatory and high-frequency ventilation; however, few studies have evaluated fundamental lung mechanical local deformations under variable loading. METHODS Porcine whole lung samples were analyzed using a novel application of digital image correlation interfaced with an electromechanical ventilation system to associate the local behavior to the global volume and pressure loading in response to various inflation volumes and breathing rates. Strains, anisotropy, tissue compliance, and the evolutionary response of the inflating lung were analyzed. RESULTS Experiments demonstrated a direct and near one-to-one linear relationship between applied lung volumes and resulting local mean strain, and a nonlinear relationship between lung pressures and strains. As the applied air delivery volume was doubled, the tissue surface mean strains approximately increased from 20 to 40%, and average maximum strains measured 70-110%. The tissue strain anisotropic ratio ranged from 0.81 to 0.86 and decreased with greater inflation volumes. Local tissue compliance during the inflation cycle, associating evolutionary strains in response to inflation pressures, was also quantified. CONCLUSION Ventilation frequencies were not found to influence the local stretch response. Strain measures significantly increased and the anisotropic ratio decreased between the smallest and greatest tidal volumes. Tissue compliance did not exhibit a unifying trend. The insights provided by the real-time continuous measures, and the kinetics to kinematics pulmonary linkage established by this study offers valuable characterizations for computational models and establishes a framework for future studies to compare healthy and diseased lung mechanics to further consider alternatives for effective ventilation strategies.
Collapse
Affiliation(s)
- C A Mariano
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - S Sattari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - K A M Quiros
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - T M Nelson
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California at Riverside, Riverside, CA, USA.
- BREATHE Center, School of Medicine, University of California at Riverside, Riverside, CA, USA.
- Department of Bioengineering, University of California at Riverside, Riverside, CA, USA.
| |
Collapse
|
16
|
Dong S, Wang L, Chitano P, Coxson HO, Vasilescu DM, Paré PD, Seow CY. Lung resistance and elastance are different in ex vivo sheep lungs ventilated by positive and negative pressures. Am J Physiol Lung Cell Mol Physiol 2022; 322:L673-L682. [PMID: 35272489 DOI: 10.1152/ajplung.00464.2021] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Lung resistance (RL) and elastance (EL) can be measured during positive or negative pressure ventilation. Whether the different modes of ventilation produce different RL and EL is still being debated. Although negative pressure ventilation (NPV) is more physiological, positive pressure ventilation (PPV) is more commonly used for treating respiratory failure. In the present study we measured lung volume, airway diameter and airway volume, as well as RL and EL with PPV and NPV in explanted sheep lungs. We found that lung volume under a static pressure, either positive or negative, was not different. However, RL and EL were significantly higher in NPV at high inflation pressures. Interestingly, diameters of smaller airways (diameters < 3.5 mm) and total airway volume were significantly greater at high negative inflation pressures compared with those at high positive inflation pressures. This suggests that NPV is more effective in distending the peripheral airways, likely due to the fact that negative pressure is applied through the pleural membrane and reaches the central airways via the peripheral airways, whereas positive pressure is applied in the opposite direction. More distension of lung periphery could explain why RL is higher in NPV (vs. PPV), because the peripheral parenchyma is a major source of tissue resistance, which is a part of the RL that increases with pressure. This explanation is consistent with the finding that during high frequency ventilation (>1 Hz, where RL reflects airway resistance more than tissue resistance), the difference in RL between NPV and PPV disappeared.
Collapse
Affiliation(s)
- Shoujin Dong
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Respiratory Department, Chengdu First People's Hospital, Chengdu, China
| | - Lu Wang
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | - Pasquale Chitano
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | - Harvey O Coxson
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada
| | | | - Peter D Paré
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Department of Medicine, University of British Columbia, Vancouver, BC, Canada
| | - Chun Y Seow
- The UBC Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, BC, Canada.,Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
17
|
Brannen M, Kang G, Dutrisac S, Banton R, Clayton JD, Petel OE. The influence of the tertiary bronchi on dynamic lung deformation. J Mech Behav Biomed Mater 2022; 130:105181. [DOI: 10.1016/j.jmbbm.2022.105181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 02/23/2022] [Accepted: 03/12/2022] [Indexed: 10/18/2022]
|
18
|
Maghsoudi-Ganjeh M, Mariano CA, Sattari S, Arora H, Eskandari M. Developing a Lung Model in the Age of COVID-19: A Digital Image Correlation and Inverse Finite Element Analysis Framework. Front Bioeng Biotechnol 2021; 9:684778. [PMID: 34765590 PMCID: PMC8576180 DOI: 10.3389/fbioe.2021.684778] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 10/04/2021] [Indexed: 02/02/2023] Open
Abstract
Pulmonary diseases, driven by pollution, industrial farming, vaping, and the infamous COVID-19 pandemic, lead morbidity and mortality rates worldwide. Computational biomechanical models can enhance predictive capabilities to understand fundamental lung physiology; however, such investigations are hindered by the lung’s complex and hierarchical structure, and the lack of mechanical experiments linking the load-bearing organ-level response to local behaviors. In this study we address these impedances by introducing a novel reduced-order surface model of the lung, combining the response of the intricate bronchial network, parenchymal tissue, and visceral pleura. The inverse finite element analysis (IFEA) framework is developed using 3-D digital image correlation (DIC) from experimentally measured non-contact strains and displacements from an ex-vivo porcine lung specimen for the first time. A custom-designed inflation device is employed to uniquely correlate the multiscale classical pressure-volume bulk breathing measures to local-level deformation topologies and principal expansion directions. Optimal material parameters are found by minimizing the error between experimental and simulation-based lung surface displacement values, using both classes of gradient-based and gradient-free optimization algorithms and by developing an adjoint formulation for efficiency. The heterogeneous and anisotropic characteristics of pulmonary breathing are represented using various hyperelastic continuum formulations to divulge compound material parameters and evaluate the best performing model. While accounting for tissue anisotropy with fibers assumed along medial-lateral direction did not benefit model calibration, allowing for regional material heterogeneity enabled accurate reconstruction of lung deformations when compared to the homogeneous model. The proof-of-concept framework established here can be readily applied to investigate the impact of assorted organ-level ventilation strategies on local pulmonary force and strain distributions, and to further explore how diseased states may alter the load-bearing material behavior of the lung. In the age of a respiratory pandemic, advancing our understanding of lung biomechanics is more pressing than ever before.
Collapse
Affiliation(s)
- Mohammad Maghsoudi-Ganjeh
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Samaneh Sattari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Hari Arora
- Faculty of Science and Engineering, Swansea University, Swansea, United Kingdom
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States.,BREATHE Center, School of Medicine, University of California, Riverside, Riverside, CA, United States.,Department of Bioengineering, University of California, Riverside, Riverside, CA, United States
| |
Collapse
|
19
|
Vindin HJ, Oliver BG, Weiss AS. Elastin in healthy and diseased lung. Curr Opin Biotechnol 2021; 74:15-20. [PMID: 34781101 DOI: 10.1016/j.copbio.2021.10.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/12/2021] [Accepted: 10/19/2021] [Indexed: 01/05/2023]
Abstract
Elastic fibers are an essential part of the pulmonary extracellular matrix (ECM). Intact elastin is required for normal function and its damage contributes profoundly to the etiology and pathology of lung disease. This highlights the need for novel lung-specific imaging methodology that enables high-resolution 3D visualization of the ECM. We consider elastin's involvement in chronic respiratory disease and examine recent methods for imaging and modeling of the lung in the context of advances in lung tissue engineering for research and clinical application.
Collapse
Affiliation(s)
- Howard J Vindin
- Charles Perkins Centre, The University of Sydney, Sydney 2006, NSW, Australia; School of Life and Environmental Sciences, The University of Sydney, 2006 Sydney, NSW, Australia; The Woolcock Institute, The University of Sydney, Sydney 2006, NSW, Australia
| | - Brian Gg Oliver
- The Woolcock Institute, The University of Sydney, Sydney 2006, NSW, Australia
| | - Anthony S Weiss
- Charles Perkins Centre, The University of Sydney, Sydney 2006, NSW, Australia; School of Life and Environmental Sciences, The University of Sydney, 2006 Sydney, NSW, Australia; Sydney Nano Institute, The University of Sydney, 2006 Sydney, NSW, Australia.
| |
Collapse
|
20
|
|
21
|
Mariano CA, Sattari S, Maghsoudi-Ganjeh M, Tartibi M, Lo DD, Eskandari M. Novel Mechanical Strain Characterization of Ventilated ex vivo Porcine and Murine Lung using Digital Image Correlation. Front Physiol 2020; 11:600492. [PMID: 33343395 PMCID: PMC7746832 DOI: 10.3389/fphys.2020.600492] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 11/03/2020] [Indexed: 12/14/2022] Open
Abstract
Respiratory illnesses, such as bronchitis, emphysema, asthma, and COVID-19, substantially remodel lung tissue, deteriorate function, and culminate in a compromised breathing ability. Yet, the structural mechanics of the lung is significantly understudied. Classical pressure-volume air or saline inflation studies of the lung have attempted to characterize the organ’s elasticity and compliance, measuring deviatory responses in diseased states; however, these investigations are exclusively limited to the bulk composite or global response of the entire lung and disregard local expansion and stretch phenomena within the lung lobes, overlooking potentially valuable physiological insights, as particularly related to mechanical ventilation. Here, we present a method to collect the first non-contact, full-field deformation measures of ex vivo porcine and murine lungs and interface with a pressure-volume ventilation system to investigate lung behavior in real time. We share preliminary observations of heterogeneous and anisotropic strain distributions of the parenchymal surface, associative pressure-volume-strain loading dependencies during continuous loading, and consider the influence of inflation rate and maximum volume. This study serves as a crucial basis for future works to comprehensively characterize the regional response of the lung across various species, link local strains to global lung mechanics, examine the effect of breathing frequencies and volumes, investigate deformation gradients and evolutionary behaviors during breathing, and contrast healthy and pathological states. Measurements collected in this framework ultimately aim to inform predictive computational models and enable the effective development of ventilators and early diagnostic strategies.
Collapse
Affiliation(s)
- Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Samaneh Sattari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Mohammad Maghsoudi-Ganjeh
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | | | - David D Lo
- Division of Biomedical Sciences, School of Medicine, University of California, Riverside, Riverside, CA, United States.,BREATHE Center, School of Medicine, University of California, Riverside, Riverside, CA, United States
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States.,BREATHE Center, School of Medicine, University of California, Riverside, Riverside, CA, United States.,Department of Bioengineering, Riverside, CA, United States
| |
Collapse
|
22
|
Sattari S, Mariano CA, Vittalbabu S, Velazquez JV, Postma J, Horst C, Teh E, Nordgren TM, Eskandari M. Introducing a Custom-Designed Volume-Pressure Machine for Novel Measurements of Whole Lung Organ Viscoelasticity and Direct Comparisons Between Positive- and Negative-Pressure Ventilation. Front Bioeng Biotechnol 2020; 8:578762. [PMID: 33195138 PMCID: PMC7643401 DOI: 10.3389/fbioe.2020.578762] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 09/17/2020] [Indexed: 12/13/2022] Open
Abstract
Asthma, emphysema, COVID-19 and other lung-impacting diseases cause the remodeling of tissue structural properties and can lead to changes in conducting pulmonary volume, viscoelasticity, and air flow distribution. Whole organ experimental inflation tests are commonly used to understand the impact of these modifications on lung mechanics. Here we introduce a novel, automated, custom-designed device for measuring the volume and pressure response of lungs, surpassing the capabilities of traditional machines and built to range size-scales to accommodate both murine and porcine tests. The software-controlled system is capable of constructing standardized continuous volume-pressure curves, while accounting for air compressibility, yielding consistent and reproducible measures while eliminating the need for pulmonary degassing. This device uses volume-control to enable viscoelastic whole lung macromechanical insights from rate dependencies and pressure-time curves. Moreover, the conceptual design of this device facilitates studies relating the phenomenon of diaphragm breathing and artificial ventilation induced by pushing air inside the lungs. System capabilities are demonstrated and validated via a comparative study between ex vivo murine lungs and elastic balloons, using various testing protocols. Volume-pressure curve comparisons with previous pressure-controlled systems yield good agreement, confirming accuracy. This work expands the capabilities of current lung experiments, improving scientific investigations of healthy and diseased pulmonary biomechanics. Ultimately, the methodologies demonstrated in the manufacturing of this system enable future studies centered on investigating viscoelasticity as a potential biomarker and improvements to patient ventilators based on direct assessment and comparisons of positive- and negative-pressure mechanics.
Collapse
Affiliation(s)
- Samaneh Sattari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Crystal A Mariano
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Swathi Vittalbabu
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
| | - Jalene V Velazquez
- BREATHE Center at the School of Medicine, University of California, Riverside, Riverside, CA, United States.,Division of Biomedical Sciences, School of Medicine, University of California, Riverside, Riverside, CA, United States
| | | | - Caleb Horst
- CellScale Biomaterials Testing, Waterloo, ON, Canada
| | - Eric Teh
- CellScale Biomaterials Testing, Waterloo, ON, Canada
| | - Tara M Nordgren
- BREATHE Center at the School of Medicine, University of California, Riverside, Riverside, CA, United States.,Division of Biomedical Sciences, School of Medicine, University of California, Riverside, Riverside, CA, United States
| | - Mona Eskandari
- Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States.,BREATHE Center at the School of Medicine, University of California, Riverside, Riverside, CA, United States.,Department of Bioengineering, University of California, Riverside, Riverside, CA, United States
| |
Collapse
|