1
|
Şentürk Z. A Journey from the Drops of Mercury to the Mysterious Shores of the Brain: The 100-Year Adventure of Voltammetry. Crit Rev Anal Chem 2022:1-12. [PMID: 35994268 DOI: 10.1080/10408347.2022.2113760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Voltammetry, which is at the core of electroanalytical chemistry, is an analytical method that investigates and evaluates the current-potential relationship obtained at a given working electrode. If it is used dropping mercury as working electrode, the method is called as polarography. The current year 2022 marks the 100th anniversary of the discovery of polarography by Czech Jaroslav Heyrovský. He received the Nobel Prize in Chemistry in 1959 for this discovery and his contribution to the scientific world. A hundred years, within the endless existence of the universe is maybe nothing. A hundred years, in the history of mankind is a line, maybe a short paragraph. But, in science, a hundred years can lead to very significant advances in a field and often to the birth and establishment of an entirely new scientific discipline. Indeed, in the last hundred years, the design and use of new electrochemical devices, depending on the progress in microelectronics and computer technologies, has almost revolutionized voltammetry. Besides these developments, due to the fact that the redox (oxidation/reduction) process is very basic for living organisms; the voltammetry, especially with the beginning of the 21st century, has started to be used as a very powerful tool in neuroscience to solve the mystery of the brain (the basic problems of biomolecules with physiological and genetic importance in brain tissue). This review article is an overview of the 100-year history and fascinating development of voltammetry from Heyrovský to the present.
Collapse
Affiliation(s)
- Zühre Şentürk
- Faculty of Science, Department of Analytical Chemistry, Van Yuzuncu Yil University, Van, Turkey
| |
Collapse
|
2
|
Liu R, Feng ZY, Li D, Jin B, Yan Lan, Meng LY. Recent trends in carbon-based microelectrodes as electrochemical sensors for neurotransmitter detection: A review. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116541] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
3
|
Robke R, Hashemi P, Ramsson E. A simplified LED-driven switch for fast-scan controlled-adsorption voltammetry instrumentation. HARDWAREX 2019; 5:e00051. [PMID: 34113744 PMCID: PMC8189313 DOI: 10.1016/j.ohx.2018.e00051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Fast-scan cyclic voltammetry (FSCV) is an analytical tool used to probe neurochemical processes in real-time. A major drawback for specialized applications of FSCV is that instrumentation must be constructed or modified in-house by those with expertise in electronics. One such specialized application is the newly developed fast-scan controlled-adsorption voltammetry (FSCAV) that measures basal (tonic) in vivo dopamine and serotonin concentrations. FSCAV requires additional software and equipment (an operational amplifier coupled to a transistor-transistor logic) allowing the system to switch between applying a FSCV waveform and a constant potential to the working electrode. Herein we describe a novel, simplified switching component to facilitate the integration of FSCAV into existing FSCV instruments, thereby making this method more accessible to the community. Specifically, we employ two light emitting diodes (LEDs) to generate the voltage needed to drive a NPN bipolar junction transistor, substantially streamlining the circuitry and fabrication of the switching component. We performed in vitro and in vivo analyses to compare the new LED circuit vs. the original switch. Our data shows that the novel simplified switching component performs equally well when compared to traditional instrumentation. Thus, we present a new, simplified scheme to perform FSCAV that is cheap, simple, and easy to construct by individuals without a background in engineering and electronics.
Collapse
Affiliation(s)
- Rhiannon Robke
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, USA
| | - Parastoo Hashemi
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, USA
| | - Eric Ramsson
- Department of Biomedical Science, Grand Valley State University, Allendale, MI, USA
- Corresponding author. (E. Ramsson)
| |
Collapse
|
4
|
Nicolai EN, Michelson NJ, Settell ML, Hara SA, Trevathan JK, Asp AJ, Stocking KC, Lujan JL, Kozai TDY, Ludwig KA. Design Choices for Next-Generation Neurotechnology Can Impact Motion Artifact in Electrophysiological and Fast-Scan Cyclic Voltammetry Measurements. MICROMACHINES 2018; 9:E494. [PMID: 30424427 PMCID: PMC6215211 DOI: 10.3390/mi9100494] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 09/15/2018] [Accepted: 09/21/2018] [Indexed: 12/23/2022]
Abstract
Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.
Collapse
Affiliation(s)
- Evan N Nicolai
- Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN 55905, USA.
| | - Nicholas J Michelson
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- Department of Psychiatry, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
| | - Megan L Settell
- Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN 55905, USA.
| | - Seth A Hara
- Division of Engineering, Mayo Clinic, Rochester, MN 55905, USA.
| | - James K Trevathan
- Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN 55905, USA.
| | - Anders J Asp
- Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN 55905, USA.
| | - Kaylene C Stocking
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
| | - J Luis Lujan
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, USA.
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA.
| | - Takashi D Y Kozai
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- Center for the Neural Basis of Cognition, University of Pittsburgh and Carnegie Mellon University, Pittsburgh, PA 15213, USA.
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15213, USA.
- NeuroTech Center of the University of Pittsburgh Brain Institute, Pittsburgh, PA 15213, USA.
- Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA 15213, USA.
| | - Kip A Ludwig
- Department of Bioengineering, University of Wisconsin, Madison, WI 53706, USA.
- Department of Neurological Surgery, University of Wisconsin, Madison, WI 53706, USA.
| |
Collapse
|
5
|
Dorta-Quiñones CI, Wang XY, Dokania RK, Gailey A, Lindau M, Apsel AB. A Wireless FSCV Monitoring IC With Analog Background Subtraction and UWB Telemetry. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:289-99. [PMID: 26057983 PMCID: PMC4793395 DOI: 10.1109/tbcas.2015.2421513] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5- mm(2) chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pA(rms) and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm(2), weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV.
Collapse
Affiliation(s)
| | - Xiao Y. Wang
- Cornell University, Ithaca, NY 14853 USA. He is now with MIT Lincoln Laboratory, Lexington, MA 02420 USA ()
| | - Rajeev K. Dokania
- Cornell University, Ithaca, NY 14853 USA. He is now with Intel Corporation, Hillsboro, OR 97124 USA ()
| | - Alycia Gailey
- Cornell University, Ithaca, NY 14853 USA. She is now with the School of Biological and Health Systems Engineering in Arizona State University, Tempe, AZ 85287 USA ()
| | - Manfred Lindau
- School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853 USA ()
| | - Alyssa B. Apsel
- School of Electrical and Computer Engineering, Cornell University, Ithaca, NY 14853 USA ()
| |
Collapse
|
6
|
Ebrazeh A, Bozorgzadeh B, Mohseni P. Impulse radio ultra wideband wireless transmission of dopamine concentration levels recorded by fast-scan cyclic voltammetry. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7103-6. [PMID: 26737929 DOI: 10.1109/embc.2015.7320029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This paper demonstrates the feasibility of utilizing impulse radio ultra wideband (IR-UWB) signaling technique for reliable, wireless transmission of dopamine concentration levels recorded by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) to address the problem of elevated data rates in high-channel-count neurochemical monitoring. Utilizing an FSCV-sensing chip fabricated in AMS 0.35μm 2P/4M CMOS, a 3-5-GHz, IR-UWB transceiver (TRX) chip fabricated in TSMC 90nm 1P/9M RF CMOS, and two off-chip, miniature, UWB antennae, wireless transfer of pseudo-random binary sequence (PRBS) data at 50Mbps over a distance of <;1m is first shown with bit-error rates (BER) <; 10(-3). Further, IR-UWB wireless transmission of dopamine concentration levels prerecorded with FSCV at a CFM during flow injection analysis (FIA) is also demonstrated with transmitter (TX) power dissipation of only ~4.4μW from 1.2V, representing two orders of magnitude reduction in TX power consumption compared to that of a conventional frequency-shift-keyed (FSK) link operating at ~433MHz.
Collapse
|
7
|
Smith AR, Garris PA, Casto JM. Real-time monitoring of electrically evoked catecholamine signals in the songbird striatum using in vivo fast-scan cyclic voltammetry. J Chem Neuroanat 2015; 66-67:28-39. [PMID: 25900708 DOI: 10.1016/j.jchemneu.2015.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Revised: 04/04/2015] [Accepted: 04/04/2015] [Indexed: 01/06/2023]
Abstract
Fast-scan cyclic voltammetry is a powerful technique for monitoring rapid changes in extracellular neurotransmitter levels in the brain. In vivo fast-scan cyclic voltammetry has been used extensively in mammalian models to characterize dopamine signals in both anesthetized and awake preparations, but has yet to be applied to a non-mammalian vertebrate. The goal of this study was to establish in vivo fast-scan cyclic voltammetry in a songbird, the European starling, to facilitate real-time measurements of extracellular catecholamine levels in the avian striatum. In urethane-anesthetized starlings, changes in catecholamine levels were evoked by electrical stimulation of the ventral tegmental area and measured at carbon-fiber microelectrodes positioned in the medial and lateral striata. Catecholamines were elicited by different stimulations, including trains related to phasic dopamine signaling in the rat, and were analyzed to quantify presynaptic mechanisms governing exocytotic release and neuronal uptake. Evoked extracellular catecholamine dynamics, maximal amplitude of the evoked catecholamine signal, and parameters for catecholamine release and uptake did not differ between striatal regions and were similar to those determined for dopamine in the rat dorsomedial striatum under similar conditions. Chemical identification of measured catecholamine by its voltammogram was consistent with the presence of both dopamine and norepinephrine in striatal tissue content. However, the high ratio of dopamine to norepinephrine in tissue content and the greater sensitivity of the carbon-fiber microelectrode to dopamine compared to norepinephrine favored the measurement of dopamine. Thus, converging evidence suggests that dopamine was the predominate analyte of the electrically evoked catecholamine signal measured in the striatum by fast-scan cyclic voltammetry. Overall, comparisons between the characteristics of these evoked signals suggested a similar presynaptic regulation of dopamine in the starling and rat striatum. Fast-scan cyclic voltammetry thus has the potential to be an invaluable tool for investigating the neural underpinnings of behavior in birds.
Collapse
Affiliation(s)
- Amanda R Smith
- School of Biological Sciences, Illinois State University, Campus Box 4120, Normal, IL 61790-4120, USA.
| | - Paul A Garris
- School of Biological Sciences, Illinois State University, Campus Box 4120, Normal, IL 61790-4120, USA
| | - Joseph M Casto
- School of Biological Sciences, Illinois State University, Campus Box 4120, Normal, IL 61790-4120, USA
| |
Collapse
|
8
|
Farina D, Alvau MD, Puggioni G, Calia G, Bazzu G, Migheli R, Sechi O, Rocchitta G, Desole MS, Serra PA. Implantable (Bio)sensors as new tools for wireless monitoring of brain neurochemistry in real time. World J Pharmacol 2014; 3:1-17. [DOI: 10.5497/wjp.v3.i1.1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 05/01/2014] [Accepted: 05/29/2014] [Indexed: 02/06/2023] Open
Abstract
Implantable electrochemical microsensors are characterized by high sensitivity, while amperometric biosensors are very selective in virtue of the biological detecting element. Each sensor, specific for every neurochemical species, is a miniaturized high-technology device resulting from the combination of several factors: electrode material, shielding polymers, applied electrochemical technique, and in the case of biosensors, biological sensing material, stabilizers, and entrapping chemical nets. In this paper, we summarize the available technology for the in vivo electrochemical monitoring of neurotransmitters (dopamine, norepinephrine, serotonin, acetylcholine, and glutamate), bioenergetic substrates (glucose, lactate, and oxygen), neuromodulators (ascorbic acid and nitric oxide), and exogenous molecules such as ethanol. We also describe the most represented biotelemetric technologies in order to wirelessly transmit the signals of the above-listed neurochemicals. Implantable (Bio)sensors, integrated into miniaturized telemetry systems, represent a new generation of analytical tools that could be used for studying the brain’s physiology and pathophysiology and the effects of different drugs (or toxic chemicals such as ethanol) on neurochemical systems.
Collapse
|
9
|
Chandra S, Miller AD, Bendavid A, Martin PJ, Wong DKY. Minimizing Fouling at Hydrogenated Conical-Tip Carbon Electrodes during Dopamine Detection in Vivo. Anal Chem 2014; 86:2443-50. [DOI: 10.1021/ac403283t] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
| | | | - Avi Bendavid
- CSIRO Materials
Science and Engineering, P.O. Box 218, Lindfield, New South Wales 2070, Australia
| | - Philip J. Martin
- CSIRO Materials
Science and Engineering, P.O. Box 218, Lindfield, New South Wales 2070, Australia
| | | |
Collapse
|
10
|
Rocchitta G, Secchi O, Alvau MD, Farina D, Bazzu G, Calia G, Migheli R, Desole MS, O'Neill RD, Serra PA. Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats. Anal Chem 2013; 85:10282-8. [PMID: 24102201 DOI: 10.1021/ac402071w] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
A new telemetry system for simultaneous detection of extracellular brain glucose and lactate and motion is presented. The device consists of dual-channel, single-supply miniature potentiostat-I/V converter, a microcontroller unit, a signal transmitter, and a miniaturized microvibration sensor. Although based on simple and inexpensive components, the biotelemetry device has been used for accurate transduction of the anodic oxidation currents generated on the surface of implanted glucose and lactate biosensors and animal microvibrations. The device was characterized and validated in vitro before in vivo experiments. The biosensors were implanted in the striatum of freely moving animals and the biotelemetric device was fixed to the animal's head. Physiological and pharmacological stimulations were given in order to induce striatal neural activation and to modify the motor behavior in awake, untethered animals.
Collapse
Affiliation(s)
- Gaia Rocchitta
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari , Viale S. Pietro 43/b, 07100 Sassari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Li YT, Wickens JR, Huang YL, Pan WHT, Chen FYB, Chen JJJ. Integrated wireless fast-scan cyclic voltammetry recording and electrical stimulation for reward-predictive learning in awake, freely moving rats. J Neural Eng 2013; 10:046007. [PMID: 23770892 DOI: 10.1088/1741-2560/10/4/046007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Fast-scan cyclic voltammetry (FSCV) is commonly used to monitor phasic dopamine release, which is usually performed using tethered recording and for limited types of animal behavior. It is necessary to design a wireless dopamine sensing system for animal behavior experiments. APPROACH This study integrates a wireless FSCV system for monitoring the dopamine signal in the ventral striatum with an electrical stimulator that induces biphasic current to excite dopaminergic neurons in awake freely moving rats. The measured dopamine signals are unidirectionally transmitted from the wireless FSCV module to the host unit. To reduce electrical artifacts, an optocoupler and a separate power are applied to isolate the FSCV system and electrical stimulator, which can be activated by an infrared controller. MAIN RESULTS In the validation test, the wireless backpack system has similar performance in comparison with a conventional wired system and it does not significantly affect the locomotor activity of the rat. In the cocaine administration test, the maximum electrically elicited dopamine signals increased to around 230% of the initial value 20 min after the injection of 10 mg kg(-1) cocaine. In a classical conditioning test, the dopamine signal in response to a cue increased to around 60 nM over 50 successive trials while the electrically evoked dopamine concentration decreased from about 90 to 50 nM in the maintenance phase. In contrast, the cue-evoked dopamine concentration progressively decreased and the electrically evoked dopamine was eliminated during the extinction phase. In the histological evaluation, there was little damage to brain tissue after five months chronic implantation of the stimulating electrode. SIGNIFICANCE We have developed an integrated wireless voltammetry system for measuring dopamine concentration and providing electrical stimulation. The developed wireless FSCV system is proven to be a useful experimental tool for the continuous monitoring of dopamine levels during animal learning behavior studies of freely moving rats.
Collapse
Affiliation(s)
- Yu-Ting Li
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan, Republic of China
| | | | | | | | | | | |
Collapse
|
12
|
Kasasbeh A, Lee K, Bieber A, Bennet K, Chang SY. Wireless neurochemical monitoring in humans. Stereotact Funct Neurosurg 2013; 91:141-7. [PMID: 23445903 DOI: 10.1159/000345111] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Accepted: 09/19/2012] [Indexed: 01/15/2023]
Abstract
Electrochemical techniques have long been utilized to investigate chemical changes in the neuronal microenvironment. Preclinical models have demonstrated the successful monitoring of changes in various neurotransmitter systems in vivo with high temporal and spatial resolution. The expansion of electrochemical recording to humans is a critical yet challenging goal to elucidate various aspects of human neurophysiology and to create future therapies. We have designed a novel device named the WINCS (Wireless Instantaneous Neurotransmitter Concentration Sensing) system that combines rapid scan voltammetry with wireless telemetry for highly resolved electrochemical recording and analysis. WINCS utilizes fast-scan cyclic voltammetry and fixed potential amperometry for in vivo recording and has demonstrated high temporal and spatial resolution in detecting changes in extracellular levels of a wide range of analytes including dopamine, adenosine, glutamate, serotonin, and histamine. Neurochemical monitoring in humans represents a new approach to understanding the neurophysiology of the central nervous system, the neurobiology of numerous diseases, and the underlying mechanism of various neurosurgical therapies. This article addresses the current understanding of electrochemistry, its application in humans, and future directions.
Collapse
Affiliation(s)
- Aimen Kasasbeh
- Department of Neurosurgery, Mayo Clinic, Rochester, MN 55905, USA
| | | | | | | | | |
Collapse
|
13
|
Roberts JG, Lugo-Morales LZ, Loziuk PL, Sombers LA. Real-time chemical measurements of dopamine release in the brain. Methods Mol Biol 2013; 964:275-94. [PMID: 23296789 DOI: 10.1007/978-1-62703-251-3_16] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Rapid changes in extracellular dopamine concentrations in freely moving or anesthetized rats can be detected using fast-scan cyclic voltammetry (FSCV). Background-subtracted FSCV is a real-time electrochemical technique that can monitor neurochemical transmission in the brain on a subsecond timescale, while providing chemical information on the analyte. Also, this voltammetric approach allows for the investigation of the kinetics of release and uptake of molecules in the brain. This chapter describes, completely, how to make these measurements and the properties of FSCV that make it uniquely suitable for performing chemical measurements of dopaminergic neurotransmission in vivo.
Collapse
Affiliation(s)
- James G Roberts
- Department of Chemistry, North Carolina State University, Raleigh, NC, USA
| | | | | | | |
Collapse
|
14
|
Nakazato T. Dual modes of extracellular serotonin changes in the rat ventral striatum modulate adaptation to a social stress environment, studied with wireless voltammetry. Exp Brain Res 2012; 230:583-96. [DOI: 10.1007/s00221-012-3168-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Accepted: 06/25/2012] [Indexed: 02/03/2023]
|
15
|
Zamani H, Mohseni P. A high-speed circuit architecture for IR-UWB transmission of fast-scan cyclic voltammetry in 0.35 εm CMOS. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2010:1561-4. [PMID: 21096381 DOI: 10.1109/iembs.2010.5626697] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper reports on the design of a high-speed circuit for impulse radio ultra-wideband (IR-UWB) transmission of 16-channel neurochemical activity recorded using 300-V/s fast-scan cyclic voltammetry (FSCV). Simulated in a low-cost 0.35-εm standard complementary metal-oxide-semiconductor (CMOS) technology, the circuit generates 3(rd)-derivative Gaussian pulses with sub-nanosecond duration, which are highpass filtered externally using a 4(th)-order Butterworth filter before feeding to an off-chip UWB antenna. The power spectral density (PSD) achieves a peak emission frequency of 4.6 GHz with a 2.3-GHz bandwidth (-10 dB), and is fully compliant with the UWB emission mask. The energy efficiency in pulse generation is 161.7 pJ/pulse that leads to a power consumption of 4.85 mW from 3.3 V for a data rate of 15 Mbps, when two pulses are used to transmit a single data bit.
Collapse
Affiliation(s)
- Hamidreza Zamani
- Electrical Engineering and Computer Science Department, Case Western Reserve University, Cleveland, OH 44106, USA
| | | |
Collapse
|
16
|
Bazzu G, Puggioni GGM, Dedola S, Calia G, Rocchitta G, Migheli R, Desole MS, Lowry JP, O'Neill RD, Serra PA. Real-time monitoring of brain tissue oxygen using a miniaturized biotelemetric device implanted in freely moving rats. Anal Chem 2010; 81:2235-41. [PMID: 19222224 DOI: 10.1021/ac802390f] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.
Collapse
Affiliation(s)
- Gianfranco Bazzu
- Department of Neuroscience, Medical School, University of Sassari, Viale S. Pietro 43/b, 07100 Sassari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Van Gompel JJ, Chang SY, Goerss SJ, Kim IY, Kimble C, Bennet KE, Lee KH. Development of intraoperative electrochemical detection: wireless instantaneous neurochemical concentration sensor for deep brain stimulation feedback. Neurosurg Focus 2010; 29:E6. [PMID: 20672923 PMCID: PMC2939376 DOI: 10.3171/2010.5.focus10110] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Deep brain stimulation (DBS) is effective when there appears to be a distortion in the complex neurochemical circuitry of the brain. Currently, the mechanism of DBS is incompletely understood; however, it has been hypothesized that DBS evokes release of neurochemicals. Well-established chemical detection systems such as microdialysis and mass spectrometry are impractical if one is assessing changes that are happening on a second-to-second time scale or for chronically used implanted recordings, as would be required for DBS feedback. Electrochemical detection techniques such as fast-scan cyclic voltammetry (FSCV) and amperometry have until recently remained in the realm of basic science; however, it is enticing to apply these powerful recording technologies to clinical and translational applications. The Wireless Instantaneous Neurochemical Concentration Sensor (WINCS) currently is a research device designed for human use capable of in vivo FSCV and amperometry, sampling at subsecond time resolution. In this paper, the authors review recent advances in this electrochemical application to DBS technologies. The WINCS can detect dopamine, adenosine, and serotonin by FSCV. For example, FSCV is capable of detecting dopamine in the caudate evoked by stimulation of the subthalamic nucleus/substantia nigra in pig and rat models of DBS. It is further capable of detecting dopamine by amperometry and, when used with enzyme linked sensors, both glutamate and adenosine. In conclusion, WINCS is a highly versatile instrument that allows near real-time (millisecond) detection of neurochemicals important to DBS research. In the future, the neurochemical changes detected using WINCS may be important as surrogate markers for proper DBS placement as well as the sensor component for a "smart" DBS system with electrochemical feedback that allows automatic modulation of stimulation parameters. Current work is under way to establish WINCS use in humans.
Collapse
Affiliation(s)
| | - Su-Youne Chang
- Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota
| | - Stephan J. Goerss
- Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota
| | - In Yong Kim
- Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota
| | | | | | - Kendall H. Lee
- Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota
- Division of Engineering, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
18
|
Kimble CJ, Johnson DM, Winter BA, Whitlock SV, Kressin KR, Horne AE, Robinson JC, Bledsoe JM, Tye SJ, Chang SY, Agnesi F, Griessenauer CJ, Covey D, Shon YM, Bennet KE, Garris PA, Lee KH. Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) for intraoperative neurochemical monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:4856-9. [PMID: 19963865 DOI: 10.1109/iembs.2009.5332773] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans - a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery.
Collapse
|
19
|
Bledsoe JM, Kimble CJ, Covey DP, Blaha CD, Agnesi F, Mohseni P, Whitlock S, Johnson DM, Horne A, Bennet KE, Lee KH, Garris PA. Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry. J Neurosurg 2009; 111:712-23. [PMID: 19425890 PMCID: PMC2808191 DOI: 10.3171/2009.3.jns081348] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. METHODS The FSCV study consisted of a triangle wave scanned between -0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 mum) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by approximately 100 microm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. RESULTS The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus-connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. CONCLUSIONS Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.
Collapse
Affiliation(s)
| | | | - Daniel P. Covey
- Department of Biological Sciences, Illinois State University, Normal, Illinois
| | | | - Filippo Agnesi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | - Pedram Mohseni
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, Ohio
| | | | | | - April Horne
- Division of Engineering, Mayo Clinic, Rochester, Minnesota
| | | | - Kendall H. Lee
- Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | - Paul A. Garris
- Department of Biological Sciences, Illinois State University, Normal, Illinois
| |
Collapse
|
20
|
Lee KH, Blaha CD, Garris PA, Mohseni P, Horne AE, Bennet KE, Agnesi F, Bledsoe JM, Lester DB, Kimble C, Min HK, Kim YB, Cho ZH. Evolution of Deep Brain Stimulation: Human Electrometer and Smart Devices Supporting the Next Generation of Therapy. Neuromodulation 2009; 12:85-103. [PMID: 20657744 DOI: 10.1111/j.1525-1403.2009.00199.x] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Deep Brain Stimulation (DBS) provides therapeutic benefit for several neuropathologies including Parkinson's disease (PD), epilepsy, chronic pain, and depression. Despite well established clinical efficacy, the mechanism(s) of DBS remains poorly understood. In this review we begin by summarizing the current understanding of the DBS mechanism. Using this knowledge as a framework, we then explore a specific hypothesis regarding DBS of the subthalamic nucleus (STN) for the treatment of PD. This hypothesis states that therapeutic benefit is provided, at least in part, by activation of surviving nigrostriatal dopaminergic neurons, subsequent striatal dopamine release, and resumption of striatal target cell control by dopamine. While highly controversial, we present preliminary data that are consistent with specific predications testing this hypothesis. We additionally propose that developing new technologies, e.g., human electrometer and closed-loop smart devices, for monitoring dopaminergic neurotransmission during STN DBS will further advance this treatment approach.
Collapse
Affiliation(s)
- Kendall H Lee
- Department of Neurosurgery and Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Development of a Parallel-Computing Embedded Telemetry System for Voltammetric Microsensor and Biosensor Applications. SENSORS FOR ENVIRONMENT, HEALTH AND SECURITY 2009. [DOI: 10.1007/978-1-4020-9009-7_14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
22
|
Nematollahi D, Shayani-jam H. Kinetic Study of Electrochemically Induced Michael Reactions of o-Quinones with Meldrum’s Acid Derivatives. Synthesis of Highly Oxygenated Catechols. J Org Chem 2008; 73:3428-34. [DOI: 10.1021/jo800115n] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- D. Nematollahi
- Faculty of Chemistry, University of Bu-Ali-Sina, Hamadan, 65174, Iran
| | - H. Shayani-jam
- Faculty of Chemistry, University of Bu-Ali-Sina, Hamadan, 65174, Iran
| |
Collapse
|
23
|
|
24
|
|
25
|
Kagohashi M, Nakazato T, Yoshimi K, Moizumi S, Hattori N, Kitazawa S. Wireless voltammetry recording in unanesthetised behaving rats. Neurosci Res 2007; 60:120-7. [PMID: 17983679 DOI: 10.1016/j.neures.2007.09.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2007] [Revised: 09/21/2007] [Accepted: 09/25/2007] [Indexed: 11/20/2022]
Abstract
In vivo voltammetry is a valuable technique for rapid measurement of dopamine in the brain of freely behaving rats. Using a conventional voltammetry system, however, behavioural freedom is restricted by cables connecting the head assembly to the measurement system. To overcome these difficulties, we developed a wireless voltammetry system utilizing radio waves. This system consisted of a potentiostat and transmitter system that was mounted on the back of the rat, and a receiver and analysis system. A single-step pulse (100-250 mV) was applied at 4 Hz after an activation pulse to a carbon fibre recording electrode (diameter: 7 microm). Measurement of dopamine (detection limit: 2.7 x 10(-7)M) was demonstrated in vitro. In vivo experiment was performed at least 1 week after the recording electrode was implanted in the rat striatum. Administration of 2-phenylethylamine to rats increased dopamine signal current, which was consistent with the result in the microdialysis measurement. During a resident-intruder test, dopamine signal current in a resident rat increased upon introduction of an intruder rat. These results show that the present wireless system is useful for a long-term measurement of dopamine in behaving rats.
Collapse
Affiliation(s)
- Maki Kagohashi
- Department of Physiology, Juntendo University School of Medicine, Hongo 2-1-1, Tokyo 113-0033, Japan
| | | | | | | | | | | |
Collapse
|
26
|
Greco PG, Meisel RL, Heidenreich BA, Garris PA. Voltammetric measurement of electrically evoked dopamine levels in the striatum of the anesthetized Syrian hamster. J Neurosci Methods 2005; 152:55-64. [PMID: 16176838 DOI: 10.1016/j.jneumeth.2005.08.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2004] [Revised: 07/13/2005] [Accepted: 08/18/2005] [Indexed: 10/25/2022]
Abstract
Microdialysis measurements in the Syrian hamster clearly demonstrate a role for accumbal dopamine (DA) in female sexual behavior. However, large probe size and slow sampling rate prevent associating specific behaviors with DA changes in subregions of the heterogeneous nucleus accumbens. Fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), which affords millisecond temporal resolution at a micron-sized probe, could address these important issues. Mostly used in other rodents, e.g. rats and mice, this technique has not been applied to hamsters. The goal of the present study was to establish the measurement of DA in the nucleus accumbens of the anesthetized male Syrian hamster using FSCV at a CFM. For comparison, DA was simultaneously measured in the caudate-putamen. Stimulation of the medial forebrain bundle was used to elicit DA. Electrically evoked DA levels in both striatal regions were sensitive to location of the stimulating electrode and CFM, stimulation frequency, inhibition of DA uptake by cocaine and DA autoreceptor blockade by raclopride. Regional differences were observed for DA release and uptake parameters, and the effects of cocaine. Taken together, these results establish the measurement of electrically evoked DA levels in the hamster striatum using FSCV at a CFM.
Collapse
Affiliation(s)
- Phillip G Greco
- Cellular and Integrative Physiology Section, Department of Biological Sciences, Campus Box 4120, Illinois State University, Normal, IL 61790-4120, USA
| | | | | | | |
Collapse
|