1
|
Alves LVGL, Pires CRF, Sousa-Neto MD, Prado HS, Mazzi-Chaves JF, Candemil AP. Metal artifact reduction tool and mA levels impact on the diagnosis of fracture extension in endodontically treated teeth using cone-beam CT. Clin Oral Investig 2024; 28:531. [PMID: 39298025 DOI: 10.1007/s00784-024-05945-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 09/14/2024] [Indexed: 09/21/2024]
Abstract
AIM To evaluate the influence of different levels of metal artifact reduction (MAR) tool and milliamperage (mA) on the diagnosis of fracture extension in endodontically treated teeth using cone beam CT (CBCT). MATERIALS AND METHODS Ten maxillary premolars were endodontically treated and positioned in the empty sockets of a human maxilla covered with wax. CBCT acquisitions were performed using the Eagle Edge device (Dabi Atlante, Brazil) adjusted to 120 kVp, FOV of 4 × 6 cm, exposure time of 24 s and voxel size of 0.2 mm in 8 different conditions with different MAR (1, 2 and 3) and mA (3.2 and 6.3) levels. Crown-root fractures were simulated in the universal testing machine, and CBCT images were acquired again. Five radiologists evaluated the presence and extension of fractures with a 5-point scale. Statistical analysis was performed by analysis of variance, Tukey and Kappa test (α = 0.05). RESULTS Although different mA levels did not significantly (p > 0.05) affect the diagnosis values for fracture presence and extension, when evaluated the different levels of MAR, AUC and sensitivity showed significantly higher values (p < 0.05) for MAR 0 using 6.3 mA and kappa agreement showed significantly higher values (p < 0.05) for MAR 0 and 2 using 6.3 mA. CONCLUSIONS Although mA levels do not have a diagnostic effect when isolating the MAR level; in 6.3 mA, MAR 0 and 2 can positively influence the diagnosis of fracture extension in endodontically treated teeth using CBCT. CLINICAL RELEVANCE The isolate evaluation of dental fracture presence can overlook diagnostics error of its extension.
Collapse
Affiliation(s)
- Luísa Valente Gotardo Lara Alves
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Cassiano Ricardo Ferreira Pires
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Manoel Damião Sousa-Neto
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Heitor Silva Prado
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Jardel Francisco Mazzi-Chaves
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil.
| | - Amanda Pelegrin Candemil
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café- Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, 14040-904, Brazil
| |
Collapse
|
2
|
Gonzalez-Passos T, Barros-Costa M, Oliveira ML, Freitas DQ. Influence of tube current and metal artifact reduction on the diagnosis of external cervical resorption in teeth adjacent to a dental implant in CBCT: an ex-vivo study. Clin Oral Investig 2024; 28:356. [PMID: 38834721 DOI: 10.1007/s00784-024-05750-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/27/2024] [Indexed: 06/06/2024]
Abstract
OBJECTIVES This ex-vivo study aimed to assess the influence of tube current (mA) and metal artifact reduction (MAR) on the diagnosis of early external cervical resorption (EECR) in cone-beam computed tomography (CBCT) in the presence of an adjacent dental implant. MATERIALS AND METHODS Twenty-three single-rooted teeth were sectioned longitudinally and EECR was induced using a spherical drill and 5% nitric acid in 10 teeth. Each tooth was positioned in the socket of the lower right canine of a dry human mandible and CBCT scans were acquired using 90 kVp, voxel of 0.085 mm, field of view of 5 x 5 cm, and varying tube current (4, 8 or 12 mA), MAR (enabled or disabled) and implant conditions (with a zirconia implant in the socket of the lower right first premolar or without). Five oral radiologists evaluated the presence of EECR in a 5-point scale and the diagnostic values (area under the receiver operating characteristic curve - AUC, sensitivity, and specificity) were compared using multi-way Analysis of Variance (α = 0.05). Kappa test assessed intra-/inter-evaluator agreement. RESULTS The tube current only influenced the AUC values in the presence of the implant and when MAR disabled; in this case, 8 mA showed lower values (p<0.007). MAR did not influence the diagnostic values (p>0.05). In general, the presence of an implant reduced the AUC values (p<0.0001); sensitivity values with 8 mA and MAR disabled, and specificity values with 4 mA and MAR enabled and 8 mA regardless MAR were also decreased (p<0.0001). CONCLUSIONS Variations in tube current and MAR were unable to improve EECR detection, which was impaired by the presence of an adjacent implant. CLINICAL RELEVANCE Increasing tube current or activating MAR tool does not improve EECR diagnosis, which is hampered by the artifacts generated by dental implants.
Collapse
Affiliation(s)
- Thamiles Gonzalez-Passos
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil.
| | - Matheus Barros-Costa
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| | - Matheus L Oliveira
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil. Av. Limeira, 901, Zip Code13414903, Piracicaba, São Paulo, Brazil
| |
Collapse
|
3
|
Barros-Costa M, Barros-Candido JR, Sampaio-Oliveira M, Freitas DQ, Sverzut AT, Oliveira ML. Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide. Imaging Sci Dent 2024; 54:191-199. [PMID: 38948193 PMCID: PMC11211021 DOI: 10.5624/isd.20240016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/26/2024] [Accepted: 04/05/2024] [Indexed: 07/02/2024] Open
Abstract
Purpose The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test (α=0.05). Results Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.
Collapse
Affiliation(s)
- Matheus Barros-Costa
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Julia Ramos Barros-Candido
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Matheus Sampaio-Oliveira
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Deborah Queiroz Freitas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Alexander Tadeu Sverzut
- Division of Oral and Maxillofacial Surgery, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Matheus L Oliveira
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
4
|
Barros-Costa M, Nascimento EHL, Correia-Dantas IF, Oliveira ML, Freitas DQ. Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols. Imaging Sci Dent 2024; 54:49-56. [PMID: 38571773 PMCID: PMC10985521 DOI: 10.5624/isd.20230202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 12/07/2023] [Accepted: 12/09/2023] [Indexed: 04/05/2024] Open
Abstract
Purpose This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR (P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.
Collapse
Affiliation(s)
- Matheus Barros-Costa
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | | | - Iago Filipe Correia-Dantas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Matheus L. Oliveira
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|
5
|
Merken K, Monnens J, Marshall N, Johan N, Brasil DM, Santaella GM, Politis C, Jacobs R, Bosmans H. Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research. Med Phys 2023; 50:6714-6736. [PMID: 37602774 DOI: 10.1002/mp.16661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 07/17/2023] [Accepted: 07/17/2023] [Indexed: 08/22/2023] Open
Abstract
BACKGROUND Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE To present a methodology to develop and validate a virtual adult anthropomorphic voxel phantom for use in task-based image quality optimization studies in dental CBCT imaging research, focusing on root fracture (RF) detection tasks in the presence of metal artefacts. METHODS The phantom was developed from a CBCT scan with an isotropic voxel size of 0.2 mm, from which the main dental structures, mandible and maxilla were segmented. The missing large anatomical structures, including the spine, skull and remaining soft tissues, were segmented from a lower resolution full skull scan. Anatomical abnormalities were absent in the areas of interest. Fine detailed dental structures, that could not be segmented due to the limited resolution and noise in the clinical data, were modelled using a-priori anatomical knowledge. Model resolution of the teeth was therefore increased to 0.05 mm. Models of RFs as well as dental restorations to create the artefacts, were developed, and could be inserted in the phantom in any desired configuration. Simulated CBCT images of the models were generated using a newly developed multi-resolution simulation framework that incorporated the geometry, beam quality, noise and spatial resolution characteristics of a real dental CBCT scanner. Ray-tracing and Monte Carlo techniques were used to create the projection images, which were reconstructed using the classical FDK algorithm. Validation of the models was assessed by measurements of different tooth lengths, the pulp volume and the mandible, and comparison with reference values. Additionally, the simulated images were used in a reader study in which two oral radiologists had to score the realism level of the model's normal anatomy, as well as the modelled RFs and restorations. RESULTS A model of an adult head, as well as models of RFs and different types of dental restorations were created. Anatomical measurements were consistent with ranges reported in literature. For the tooth length measurements, the deviations from the mean reference values were less than 20%. In 77% of all the measurements, the deviations were within 10.1%. The pulp volumes, and mandible measurements were within one standard deviation of the reference values. Regarding the normal anatomy, both readers considered the realism level of the dental structures to be good. Background structures received a lower realism score due to the lack of detailed enough trabecular bone structure, which was expected but not the focus of this study. All modelled RFs were scored at least adequate by at least one of the readers, both in appearance and position. The realism level of the modelled restorations was considered to be good. CONCLUSIONS A methodology was proposed to develop and validate an anthropomorphic voxel phantom for image quality optimization studies in dental CBCT imaging, with a main focus on RF detection tasks. The methodology can be extended further to create more models representative of the clinical population.
Collapse
Affiliation(s)
- Karen Merken
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Janne Monnens
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nicholas Marshall
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nuyts Johan
- Department of Imaging and Pathology, Division of Nuclear Medicine & Molecular Imaging, KU Leuven, Leuven, Belgium
| | - Danieli Moura Brasil
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Gustavo Machado Santaella
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Constantinus Politis
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
- Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
| | - Hilde Bosmans
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| |
Collapse
|
6
|
Naralan ME, Ozdogan A, Guller MT, Miloglu O. Comparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices. J Prosthet Dent 2023:S0022-3913(23)00505-X. [PMID: 37716900 DOI: 10.1016/j.prosdent.2023.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 08/01/2023] [Accepted: 08/02/2023] [Indexed: 09/18/2023]
Abstract
STATEMENT OF PROBLEM Prosthodontic materials may cause unexpected artifacts in cone beam computed tomography (CBCT) images, but studies quantifying these artifacts are sparse. PURPOSE The purpose of this in vitro study was to compare the artifact expression of fixed prosthodontic materials with different CBCT devices. MATERIAL AND METHODS Ten prosthodontic materials (Co-Cr-Mo alloy, interim acrylic resin, polyetheretherketone, feldspathic ceramic, lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zircon core, and 3 monolithic zirconias) were scanned with 2 CBCT devices. The materials were placed in polymethyl methacrylate resin to simulate clinical conditions. To assess the impact of the devices on artifacts, the gray values of 8 areas in each material image were analyzed. The data were analyzed with the Kruskal-Wallis and Wilcoxon Signed-Rank tests (α=.05). RESULTS Statistically significant differences were found in the artifact expression of the materials (P<.001) and between CBCT devices (P<.001). CONCLUSIONS The artifact expression of polymeric and ceramic materials in CBCT images was less than that of other materials. The milliampere-second (mAs) value of CBCT devices had a significant impact on the artifact level.
Collapse
Affiliation(s)
- Muhammed Enes Naralan
- Assistant Professor, Department of Oral, Dental and Maxillofacial Radiology, Faculty of Dentistry, Recep Tayyip Erdoğan University, Rize, Turkey
| | - Alper Ozdogan
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey
| | - Mustafa Taha Guller
- Lecturer, Department of Dentistry Services, Vocational School of Health Services, Erzincan Binali Yıldırım University, Erzincan, Turkey.
| | - Ozkan Miloglu
- Professor, Department of Oral, Dental and Maxillofacial Radiology, Faculty of Dentistry, Atatürk University, Erzurum, Turkey
| |
Collapse
|
7
|
Shokri A, Eskandarloo A, Zahedi F, Karkehabadi H, Foroozandeh M, Farhadian M. Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone-beam computed tomography. AUST ENDOD J 2023; 49 Suppl 1:132-145. [PMID: 36269003 DOI: 10.1111/aej.12700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 09/24/2022] [Accepted: 10/05/2022] [Indexed: 11/28/2022]
Abstract
This study evaluated the effect of different amperage values and voxel sizes of two CBCT scanners on VRF detection in the presence of different intracanal posts. After post-space preparation, VRFs were induced in half of the samples of 20 maxillary premolars. Five different intracanal posts were passively placed in each root canal. Samples were scanned using CS 9300 and Cranex3D with two different voxel sizes and amperage setting in each unit. The diagnostic sensitivity, specificity and accuracy were compared using the Mann-Whitney and Kruskal-Wallis tests (α = 0.05). Changes in amperage and voxel size did not affect the detection of VRFs (p ⟩ 0.05). The VRF detection accuracy was the highest in fibreglass and the lowest in nickel-chromium group. Changes in amperage and voxel size within assessed values do not seem to influence the detection of VRF whereas different intracanal post-materials have significant effect on VRF detection.
Collapse
Affiliation(s)
- Abbas Shokri
- Dental Implants Research Center, Oral and Maxillofacial Radiology Department, Hamadan University of Medical Science, Hamadan, Iran
| | - Amir Eskandarloo
- Oral and Maxillofacial Radiology Department, Hamadan University of Medical Science, Hamadan, Iran
| | - Foozie Zahedi
- Oral and Maxillofacial Radiology Department, Hamadan University of Medical Science, Hamadan, Iran
| | - Hamed Karkehabadi
- Department of Endodontics, Dental School, Hamadan University of Medical Science, Hamadan, Iran
| | - Maryam Foroozandeh
- Oral and Maxillofacial Radiology Department, Hamadan University of Medical Science, Hamadan, Iran
| | - Maryam Farhadian
- Biostatistics, Modeling of Noncommunicable Diseases Research Center, Department of Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
8
|
de Lima JP, Mazzi-Chaves JF, de Sousa-Neto MD, Candemil AP. Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis? J Endod 2023; 49:1161-1168. [PMID: 37451335 DOI: 10.1016/j.joen.2023.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 07/18/2023]
Abstract
INTRODUCTION Cone-beam computed tomography (CBCT) allows three-dimensional evaluation and has high diagnostic accuracy of endodontic conditions. Considering that the most indicated protocol for endodontics should have smaller field-of-view and higher spatial resolution, a higher radiation dose may be associated. Thus, this study evaluated the accuracy of an optimized CBCT protocol for the detection of intraoperative endodontic complications. METHODS An image phantom was custom-made with a human mandible covered with Mix-D and forty mandibular first molars. The teeth were subdivided into 4 groups of endodontic complications which were simulated. All teeth were individually inserted into the left second molar socket of the phantom and CBCT images were acquired with OP 300 unit adjusted to a field-of-view of 6 × 4 cm, 90kVp, and 2 dose protocols: low and high. Furthermore, a titanium implant, a tooth with endodontic treatment, and a cobalt-chromium post were inserted into the empty sockets adjacent to the teeth of interest and additional images were acquired. Four endodontists evaluated the images and indicated the presence of endodontic complications on a 5-point scale. Sensitivity, specificity, and area under the receiver operating characteristic curve were obtained. The different groups were compared by ANOVA and Tukey tests (α = 0.05). RESULTS In most conditions, irrespective of the presence of metallic materials, the values of accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve did not differ significantly (P > .05) between the dose protocols. CONCLUSIONS Optimized CBCT protocols should be considered for the detection of intraoperative endodontic Diagnostic complications.
Collapse
Affiliation(s)
- João Pedro de Lima
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Jardel Francisco Mazzi-Chaves
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Manoel Damião de Sousa-Neto
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Amanda Pelegrin Candemil
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil.
| |
Collapse
|
9
|
Lagos de Melo LP, Queiroz PM, Moreira-Souza L, Nadaes MR, Santaella GM, Oliveira ML, Freitas DQ. Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study. Restor Dent Endod 2023; 48:e16. [PMID: 37284345 PMCID: PMC10240088 DOI: 10.5395/rde.2023.48.e16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 02/24/2023] [Accepted: 02/24/2023] [Indexed: 06/08/2023] Open
Abstract
Objectives The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.
Collapse
Affiliation(s)
- Larissa Pereira Lagos de Melo
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Polyane Mazucatto Queiroz
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Larissa Moreira-Souza
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Mariana Rocha Nadaes
- Dental Clinic Department, Division of Oral Radiology, Dental School, Federal Fluminense University, Niterói, Rio de Janeiro, Brazil
| | - Gustavo Machado Santaella
- Department of Diagnosis and Oral Health, University of Louisville, School of Dentistry, Louisville, KY, USA
| | - Matheus Lima Oliveira
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|
10
|
de Lima KL, Silva LR, de Paiva Prado TB, Silva MAG, de Freitas Silva BS, Yamamoto-Silva FP. Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:433-474. [PMID: 36700991 DOI: 10.1007/s00784-022-04797-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 11/14/2022] [Indexed: 01/27/2023]
Abstract
OBJECTIVES To evaluate the influence of image acquisition parameters (voxel, FOV, kVp, mA) on the accuracy of cone-beam computed tomography (CBCT) in detecting vertical root fracture (VRF). MATERIAL AND METHODS Searches were performed in 6 main databases and the gray literature, without restrictions of language or date. Observational clinical studies (OCS) and in vitro-extracted teeth (IV) studies were considered eligible for inclusion when investigating the accuracy (sensitivity, specificity) of CBCT in detecting VRF in human teeth. The risk of bias was assessed using QUADAS-2, and a meta-analysis was performed using Review Manager v5.4 software and Jamovi software v1.6. RESULTS A total of 60 out of 132 articles was included after fulfilling the eligibility criteria. Of these, 54 were IV studies while 6 were OCS. In the IV studies, it was seen that smaller FOV sizes tended to present higher accuracy values. The meta-analysis of the 6 OCS showed that the overall sensitivity and specificity values for 0.08 mm and 0.1 mm voxels were greater (0.84 and 0.79, respectively) than the sensitivity and specificity values for 0.125 mm and 0.2 mm voxels (0.70 and 0.55, respectively). CONCLUSIONS Despite the uncertain risk of bias found for the IV and OCS studies, smaller voxel and FOV sizes seem to provide more accurate VRF detection values when using CBCT. CLINICAL RELEVANCE This information is crucial for supporting the clinician when prescribing CBCT in cases of a clinical suspicion of VRF, and contributes to the personalization of the CBCT prescription, thereby ensuring greater accuracy in the VRF diagnosis. Registration This protocol was registered at the PROSPERO database (International Prospective Register of Systematic Review) under registration number CRD42020210118.
Collapse
Affiliation(s)
- Kaique Leite de Lima
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | - Lorena Rosa Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | | | - Maria Alves Garcia Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | - Brunno Santos de Freitas Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil. .,University of Anápolis, Anápolis, GO, Brazil.
| | - Fernanda Paula Yamamoto-Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.,University of Anápolis, Anápolis, GO, Brazil
| |
Collapse
|
11
|
Doriguêtto PVT, de Almeida D, de Lima CO, Lopes RT, Devito KL. Assessment of marginal gaps and image quality of crowns made of two different restorative materials: An in vitro study using CBCT images. J Dent Res Dent Clin Dent Prospects 2022; 16:243-250. [PMID: 37560496 PMCID: PMC10407872 DOI: 10.34172/joddd.2022.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 10/18/2022] [Indexed: 08/11/2023] Open
Abstract
Background The present study assessed the quality of images and the presence of marginal gaps on cone-beam computed tomography (CBCT) images of teeth restored with all-ceramic and metal-ceramic crowns and compared the gap sizes observed on CBCT images with those obtained on micro-CT images. Methods Thirty teeth restored with metal-ceramic and all-ceramic crowns, properly adapted and with gaps of 0.30 and 0.50 mm, were submitted to micro-CT and CBCT scans. Linear measurements corresponding to the marginal gap (MG) and the absolute marginal discrepancy (AMD) were obtained. The objective assessment of the quality of CBCT images was performed using the contrast-to-noise ratio (CNR), and the subjective assessment was defined by the diagnoses made by five examiners regarding the presence or absence of gaps. Results The measurements were always higher for CBCT, with a significant difference regarding AMD. No significant difference in image quality was observed using CNR between the crowns tested. Low accuracy and sensitivity values could be observed for both crowns. Conclusion Marginal mismatch measures were overestimated in CBCT images. No difference in image quality was observed between the crowns. The correct diagnosis of gaps was considered low, irrespective of crown type and gap size.
Collapse
Affiliation(s)
| | - Daniela de Almeida
- School of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| | | | - Ricardo Tadeu Lopes
- Nuclear Engineering Department, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Karina Lopes Devito
- Department of Dental Clinic, School of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| |
Collapse
|
12
|
Patel S, Bhuva B, Bose R. Vertical root fractures in root treated teeth-current status and future trends. Int Endod J 2022; 55 Suppl 3:804-826. [PMID: 35338655 PMCID: PMC9324143 DOI: 10.1111/iej.13737] [Citation(s) in RCA: 39] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/22/2022] [Accepted: 03/23/2022] [Indexed: 11/28/2022]
Abstract
Vertical root fracture (VRF) is a common reason for the extraction of root filled teeth. The accurate diagnosis of VRF may be challenging due to the absence of clinical signs, whilst conventional radiographic assessment is often inconclusive. However, an understanding of the aetiology of VRFs, and more importantly, the key predisposing factors, is crucial in identifying teeth that may be susceptible. Thorough clinical examination with magnification and co-axial lighting is essential in identifying VRFs, and although CBCT is unable to reliably detect VRFs per se, the pattern of bone loss typically associated with VRF can be fully appreciated, and therefore, increases the probability of correct diagnosis and management. The prevalence of VRFs in root filled teeth is significantly greater than in teeth with vital pulps, demonstrating that the combination of loss of structural integrity, presence of pre-existing fractures and biochemical effects of loss of vitality, are highly relevant. Careful assessment of the occlusal scheme, presence of deflective contacts and identification of parafunctional habits is imperative in both preventing and managing VRFs. Furthermore, anatomical factors such as root canal morphology, may predispose certain teeth to VRF. The influence of access cavity design and root canal instrumentation protocols should be considered although the impact of these on the fracture resistance of root filled teeth is not clearly validated. The post-endodontic restoration of root filled teeth should be expedient and considerate to the residual tooth structure. Posts should be placed 'passively' and excessive 'post-space' preparation should be avoided. This narrative review aims to present the aetiology, potential predisposing factors, histopathology, diagnosis and management of VRF and present perspectives for future research. Currently, there are limited options other than extraction for the management of VRF, although root resection may be considered in multi-rooted teeth. Innovative techniques to 'repair' VRFs using both orthograde and surgical approaches require further research and validation. The prevention of VRFs is critical; identifying susceptible teeth, utilizing conservative endodontic procedures, together with expedient and appropriate post-endodontic restorative procedures is paramount to reducing the incidence of terminal VRFs.
Collapse
Affiliation(s)
- Shanon Patel
- Department of Endodontology, King's College London Dental Institute, London, UK.,Specialist Practice, London, UK
| | - Bhavin Bhuva
- Department of Endodontology, King's College London Dental Institute, London, UK
| | - Raul Bose
- Department of Endodontology, King's College London Dental Institute, London, UK
| |
Collapse
|
13
|
González AR, Tosoni GM, Freitas DQ, Oliveira ML. Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography. Clin Oral Investig 2022; 26:4797-4803. [PMID: 35288809 DOI: 10.1007/s00784-022-04444-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 03/08/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT). MATERIALS AND METHODS Eighty-four CBCT volumes acquired at three mA levels of 28 teeth inserted in the dental socket of dry human skull were selected from a previous study. The teeth were divided into four groups according to the presence and absence of root fracture and endodontic filling. Five radiologists evaluated all CBCT volumes for the presence of root fracture with and without the application of "Sharpen 1x" and "Sharpen 2x" filters in OnDemand3D software. Area under the ROC curve (AUC), sensitivity, specificity, and inter- and intra-observer concordance were calculated and compared (α = 0.05). RESULTS Sharpening filters did not lead to significant differences in AUC, sensitivity, and specificity at the three mA levels tested (p > 0.05), regardless of the presence of endodontic filling (p > 0.05). However, the significant reduction of AUC observed in CBCT volumes at 4 mA without filter (p < 0.05) ceased to exist after the application of filters (p > 0.05). Sensitivity and specificity ranged from low and moderate. CONCLUSIONS The use of sharpening filters can be recommended in CBCT volumes at 4 mA for root fracture detection for leading to the same performance as those at 6.3 and 10 mA. The presence of endodontic filling material did not influence the action of filters in the diagnosis of root fracture. CLINICAL RELEVANCE Sharpening filters seem to contribute to the diagnosis of root fracture in CBCT volumes acquired with reduced radiation dose.
Collapse
Affiliation(s)
- Alexandra Robles González
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School (FOP/UNICAMP), University of Campinas, Av. Limeira, 901, Piracicaba, SP, 13414-903, Brazil
| | - Guilherme Monteiro Tosoni
- Department of Oral Diagnosis and Surgery, Division of Oral Radiology, Araraquara Dental School, São Paulo State University (FOAr/UNESP), Araraquara, SP, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School (FOP/UNICAMP), University of Campinas, Av. Limeira, 901, Piracicaba, SP, 13414-903, Brazil
| | - Matheus L Oliveira
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School (FOP/UNICAMP), University of Campinas, Av. Limeira, 901, Piracicaba, SP, 13414-903, Brazil.
| |
Collapse
|
14
|
Farias-Gomes A, Fontenele RC, Rosado LPL, Neves FS, Freitas DQ. The metal post material influences the performance of artefact reduction algorithms in CBCT images. Braz Dent J 2022; 33:31-40. [DOI: 10.1590/0103-6440202204222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/08/2021] [Indexed: 11/22/2022] Open
Abstract
Abstract This study aimed to assess the effect of the MAR tool on the expression of artefacts in different regions of a tooth restored with different types of metal posts. Alveolar sockets (anterior, and posterior region) of a mandible and an unirradicular tooth were used. Cone beam computed tomography scans of the tooth without a metal post, and with cobalt-chromium (Co-Cr), nickel-chromium (Ni-Cr), or silver-palladium (Ag-Pd) were individually obtained, with 2 MAR conditions: disabled, and enabled. In an axial reconstruction, lines of interest (LOIs) were set around the canal: 4 in oblique (mesiobuccal, distobuccal, mesiolingual, distolingual) directions, and 4 in orthogonal (mesial, distal, buccal, lingual) directions. Beam-hardening artefacts expression was determined by calculating the difference in the mean of gray values (DMGV) between the experimental and control groups for each LOI. There was no significant difference in the DMGV values between “without MAR” and “with MAR” for any LOI, in neither anterior nor posterior mandible (p>0.05), for the Ni-Cr and Co-Cr groups. For the Ag-Pd, significant differences in the DMGV values were observed between “without MAR” and “with MAR” for most LOIs (p<0.05), mainly in oblique directions in the anterior region, and mesio-distal direction in the posterior region. MAR acted mostly in hypodense artefacts (negative DMGV). The effectiveness of the MAR tool of the OP300 CBCT unit varied according to the post material tested. It was effective in reducing the expression of artefacts raised by the Ag-Pd post, mainly in the tooth regions affected by hypodense artefacts, regardless of the mandibular region.
Collapse
|
15
|
Cavalcanti MGP, Salineiro FC, Barros FM, Barros FBA. Influence of endodontic sealers artifacts in the detection of vertical root fractures. Braz Dent J 2022; 33:22-30. [DOI: 10.1590/0103-6440202204392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 11/25/2021] [Indexed: 11/22/2022] Open
Abstract
Abstract The aim of this study was to compare the influence of endodontic sealers artifacts on the detection of vertical root fracture in cone beam computed tomography (CBCT). Premolars and central incisors were assigned into five different groups: Control, Pulp Canal Sealer, AH Plus, Sealer 26, and BC Sealer (n= 10, per group). VRFs were mechanically induced and the teeth were inserted into an image phantom. Subsequently, CBCT (Cranex 3Dx, Soredex, Tuusula, Finland) images were obtained and two observers were asked separately to identify root fracture, by visual analysis. For both premolar and central incisors, kappa coefficients of intraobserver agreement varied from good to excellent (K: 80% - 87%), and the values for interobserver agreement varied from fair to moderate (K: 30% - 35%). As follows, the area under the curve (AUC) of receiver operating characteristic (ROC) values for VRFs highlighted that the use of BC sealer reduced the observers’ ability to discriminate VRFs relative to other sealers. Moreover, sensitivity values for premolars teeth ranged from 20% to 60%, and specificity ranged from 60% to 100%; while sensitivity values for central incisors ranged from 30% to 70%, and specificity ranged from 70% to 100%. In conclusion, the low sensitivity values, mainly for premolars, demonstrated the difficulty in VRF diagnosis. Furthermore, BC Sealer induced significantly more imaging artifacts than other sealers. These results highlighting that endodontic sealers may interfere with the diagnosis of VRFs.
Collapse
|
16
|
Bueno MR, Azevedo BC, Estrela C. A Critical Review of the Differential Diagnosis of Root Fracture Line in CBCT scans. Braz Dent J 2021; 32:114-128. [PMID: 34877973 DOI: 10.1590/0103-6440202104742] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 11/05/2021] [Indexed: 11/21/2022] Open
Abstract
The objective of this critical review of literature is to discuss relevant clinical factors associated with root fractures (RF) visualized by using a new CBCT software. RF constitutes a common occurrence and a challenge in clinical practice, in which the diagnosis becomes essential for the definition of rapid and precise decision-making. The characterization of RF may involve different aspects, such as orientation of the fracture line (horizontal, vertical, oblique), root position of the fracture (cervical, middle, apical third), fracture's coronal-radicular position (coronary, coronal-radicular, radicular), continuity of the fracture (crack, incomplete fracture, complete), bone extension of the fracture (supraosseous, bone level, infraosseous fracture). Imaging examinations have been routinely used to aid in the RF diagnosis. Even with high-resolution cone-beam computed tomography (CBCT) scans, many doubts often remain about the diagnostic outcome. Many interferences in the analysis of image quality to determine the diagnosis are identified, such as the sharpness, the noise, light and dark artifacts, among others. The professional's knowledge is essential for identifying the different patterns of fracture lines and their repercussions on adjacent bone tissues, as well as for the analysis of artifacts that may hide or show similarities to fracture lines. Fractures lines and root fractures that may be associated with phantom conditions that mimic fractures should be carefully analyzed. CBCT is the exam indicated to identify a root fracture. It is also added to the success of the diagnosis that the professional has scientific knowledge, training and mastery of advanced CBCT software.
Collapse
Affiliation(s)
| | - Bruno Correa Azevedo
- University of Louisville, School of Dentistry, Oral Radiology Department, Louisville, KY, USA
| | - Carlos Estrela
- Professor of Endodontics, Federal University of Goiás, Goiânia, Brazil
| |
Collapse
|
17
|
Combined Use of 2 Cone-beam Computed Tomography Scans in the Assessment of Vertical Root Fracture in Teeth with Intracanal Material. J Endod 2021; 47:1132-1137. [DOI: 10.1016/j.joen.2021.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 03/06/2021] [Accepted: 04/04/2021] [Indexed: 11/20/2022]
|
18
|
Bahmani A, Karkehabadi H, Shokri A, Farhadian M. Performance of Bioceramic-based Root Filling Material with Artifact Reduction Properties in the Detection of Vertical Root Fractures Using Cone-beam Computed Tomography. Open Dent J 2021. [DOI: 10.2174/1874210602115010170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Introduction:
In Cone-beam Computed Tomography (CBCT) images, metallic artifacts by root filling materials reduce the quality of images. It seems that bioceramic sealers produce fewer artifacts than gutta-percha. In this situation, the possibility of VRF detection could increase, and therefore, flap and exploratory surgery would not be needed. The purpose of this study was to evaluate the performance of a bioceramic-based root filling material in the detection of Vertical Root Fractures (VRF) in CBCT imaging.
Materials and Methods:
This study was conducted at the dental school from March to August 2019, and 100 healthy human mandibular premolar teeth were obtained and randomly divided into two equal groups. The teeth were filled with either AH26 and gutta-percha or bioceramic root filling materials. VRF was induced on half of the decoronated teeth in each group using a Global Testing Machine, and the others were considered control. CBCT imaging was performed by the Cranex 3D machine. Comparisons of the 2 groups were made using the Mann-Whitney test.
Results:
There was a significant difference between the two groups of bioceramic and gutta-percha in the measured indices, including sensitivity (P=0.017), specificity (P=0.018), positive predictive value (P=0.018), negative predictive value (P=0.018), and accuracy (P=0.011). The Area Under Curve (AUC) also showed a significant difference between the two groups (P=0.011). According to Kappa test results, no significant difference was obtained between the findings of the two observers.
Conclusion:
Different root filling materials showed a different extent of artifact in CBCT images. Bioceramic root filling material induces fewer artifacts in CBCT images, and the diagnostic value of VRF in CBCT images in the root canals filled with it is greater than those filled with AH26 and gutta-percha.
Collapse
|
19
|
Caetano AP, Sousa TO, Oliveira MR, Evanglista K, Bueno JM, Silva MA. Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures. Dentomaxillofac Radiol 2021; 50:20200334. [PMID: 33259236 DOI: 10.1259/dmfr.20200334] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES The aim of this study was to compare the accuracy of vertical root fracture (VRF) detection using three tomography devices and two software systems in teeth with different endodontic fillings. METHODS The sample consisted of 45 premolars divided into 3 groups: No filling (NF, n=15); Gutta percha (GP, n=15) and Metallic Post (MP, n=15). Cone-beam computed tomography (CBCT) images were acquired in Kodak 9000 3D, Orthopantomography 300 (OP300) and PreXion 3D devices, before and after induced root fractures. Two oral radiologists analyzed all images using InVivoDental and e-Vol DX software systems. The analysis was repeated after 15 days in 30% of the sample. Data analysis compared receiver operating characteristic (ROC) curves, as well the areas under the ROC curves. Accuracy, sensitivity, specificity, positive and negative predictive value were calculated according to each tomographic device and software. Intra- and interexaminer reliability were tested using the Kappa coefficient. RESULTS The highest accuracy was seen in the image set from the PreXion 3D, using InVivo (0.96) or e-Vol DX (0.92) in image analysis. The OP300 device presented a similar performance of the PreXion 3D in teeth with different endodontic fillings. When using e-Vol DX, the accuracy of Kodak 9000 3D improved from 0.62 to 0.74. CONCLUSIONS The PreXion 3D device is the most accurate when detecting VRF, with a performance similar to the OP300 in endodontic filled teeth. Kodak 9000 3D is indicated for teeth without fillings, with better accuracy using e-Vol DX software.
Collapse
Affiliation(s)
- Aline Pf Caetano
- Faculty of Dentistry, Federal University of Goiás, Goiânia, Goiás, Brazil
| | | | - Mariana R Oliveira
- Faculty of Dentistry, Federal University of Goiás, Goiânia, Goiás, Brazil
| | - Karine Evanglista
- Faculty of Dentistry, Federal University of Goiás, Goiânia, Goiás, Brazil
| | - Juliano M Bueno
- São Leopoldo Mandic, Private Practioner, Goiânia, Goiás, Brazil
| | - Maria Ag Silva
- Faculty of Dentistry, Federal University of Goiás, Goiânia, Goiás, Brazil
| |
Collapse
|
20
|
Mancini AXM, Santos MUC, Gaêta-Araujo H, Tirapelli C, Pauwels R, Oliveira-Santos C. Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction. Clin Oral Investig 2021; 25:5087-5094. [PMID: 33544197 DOI: 10.1007/s00784-021-03821-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 01/29/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the effect of cone-beam computed tomography (CBCT) tube current (mA) on the magnitude of artefacts at different distances from titanium or zirconia implants, with and without activation of a proprietary metal artefact reduction (MAR). MATERIAL AND METHODS Human mandibles were scanned on an OP300 Maxio CBCT unit (Instrumentarium, Tuusula, Finland) before and after the installation of dental implants, with four different tube currents (4 mA, 6.3 mA, 8 mA and 10 mA), with and without activation of proprietary MAR. The effect of mA on the standard deviation (SD) of gray values and contrast to noise ratio (CNR) were assessed in regions of interest located 1.5 cm, 2.5 cm, and 3.5 cm from implants. RESULTS In the presence of titanium implants, a significant decrease in SD was found by increasing tube current from 4 mA to 6.3 mA or 8 mA. For zirconia implants, 8 mA yielded better results for all distances. MAR improved CNR in the presence of zirconia implants at all distances, whereas no differences were observed with the use of MAR for titanium implants. CONCLUSION Increased tube current can improve overall image quality in the presence of implants, at all the distances tested. When a zirconia implant is present, such increase in mA should be higher in comparison to that for examinations with titanium implants. Activation of OP300 Maxio proprietary MAR improved image quality only among examinations with zirconia implants. CLINICAL RELEVANCE Artefact-generating implants are common in the field of view of CBCT examinations. Optimal exposure parameters, such as tube current, ensure high image quality with lowest possible radiation exposure.
Collapse
Affiliation(s)
- Arthur Xavier Maseti Mancini
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil.
| | - Matheus Urias Cruz Santos
- Department of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| | - Hugo Gaêta-Araujo
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil
| | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| | - Ruben Pauwels
- Medical Physics & Quality Assessment, Department of Imaging & Pathology, Catholic University of Leuven, Leuven, Belgium and Aarhus Institute of Advanced Studies, Aarhus University, Høegh-Guldbergs Gade 6B, 8000, Aarhus, Denmark
| | - Christiano Oliveira-Santos
- Department of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil
| |
Collapse
|
21
|
Rodrigues CT, Jacobs R, Vasconcelos KF, Lambrechts P, Rubira-Bullen IRF, Gaêta-Araujo H, Oliveira-Santos C, Duarte MAH. Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars. Dentomaxillofac Radiol 2021; 50:20200503. [PMID: 33400563 DOI: 10.1259/dmfr.20200503] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
OBJECTIVES To evaluate the influence of artefacts in cone beam CT (CBCT) images of filled root canals in isthmus-containing molars. METHODS 10 teeth presenting canals with an isthmus were instrumented and filled with a thermoplasticised obturation technique. The teeth were scanned using a micro-CT device and two CBCT devices: 3D Accuitomo 170 (ACC) and NewTom VGi evo (NT), with different acquisition protocols: larger and smaller voxel size. Three examiners assessed the CBCT images for: (1) detection of filling voids; (2) assessment of under- or overestimation of the filling material and (3) resemblance of CBCT images to the reference standard. Analyses of Task 1 yielded accuracy, sensitivity and specificity for detection of filling voids. For tasks 2 and 3, statistical analysis was performed using Wilcoxon test. The level of significance was set at p < .05. RESULTS For Task 1, ACC showed higher sensitivity, whereas NT presented higher specificity. No significant difference was found between the protocols in ACC, however, for NT, differences between protocols were significant for all diagnostic values. In Task 2, visualisation of the filling was overestimated for NT, while for ACC, underestimation was observed. For Task 3, images with smaller voxel size were more similar to the reference image, for both CBCT devices. CONCLUSIONS Different artefacts compromise the detection of filling voids on CBCT images of canals in mandibular molars with isthmus. ACC and NT present rather similar diagnostic accuracy, even though artefact expression remains device-specific.
Collapse
Affiliation(s)
- Clarissa Teles Rodrigues
- Department of Restorative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Reinhilde Jacobs
- Department of Imaging and Pathology, Faculty of Medicine, OMFS IMPATH Research Group, KU Leuven, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Karla Faria Vasconcelos
- Department of Imaging and Pathology, Faculty of Medicine, OMFS IMPATH Research Group, KU Leuven, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Paul Lambrechts
- Department of Oral Health Sciences, Endodontology, KU Leuven and Dentistry, University Hospitals Leuven, Leuven, Belgium.,Biomaterials-BIOMAT, Leuven, Belgium
| | | | - Hugo Gaêta-Araujo
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, São Paulo, Brazil
| | - Christiano Oliveira-Santos
- Department of Stomatology, Public Oral Health, and Forensic Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Restorative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
22
|
Gulibire A, Cao Y, Gao A, Wang C, Wang T, Xie X, Liang J, Li W, Lin Z. Assessment of true vertical root fracture line in endodontically treated teeth using a new subtraction software - A Micro-CT and CBCT study. AUST ENDOD J 2020; 47:290-297. [PMID: 33314451 DOI: 10.1111/aej.12476] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 11/09/2020] [Accepted: 11/21/2020] [Indexed: 11/30/2022]
Abstract
This study aimed to find true facture lines in endodontically treated teeth on CBCT images using digital subtraction and to evaluate the influence of width of facture lines in the diagnosis. Thirty-two endodontically treated teeth with vertical root fractures (VRFs) from 30 patients were included in this study. The CBCT images of the patients and the micro-CT images of extracted teeth were imported into our digital subtraction software to distinguish the true facture lines from the streak artefacts. Of them, 23(71.87%) teeth did not present true fracture lines on the CBCT images (CBCT negative), and 9 (28.13%) teeth presented true fracture lines on the CBCT images (CBCT positive). The width of the facture lines was significantly different between these two groups (P < 0.05). To summarise, for in vivo endodontically treated teeth with subtle VRFs, many true fractures lines could not be demonstrated on CBCT images and wider fractures could be better distinguished.
Collapse
Affiliation(s)
- Aihemaiti Gulibire
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Ya Cao
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Antian Gao
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Congyue Wang
- Department of Oral and Maxillofacial Surgery, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Tiemei Wang
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Xin Xie
- Department of Stomatology, Third People's Hospital of Danyang City, Danyang, China
| | - Jiahao Liang
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Weifeng Li
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Zitong Lin
- Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| |
Collapse
|
23
|
Chen YT, Hsu TY, Liu H, Chogle S. Factors Related to the Outcomes of Cracked Teeth after Endodontic Treatment. J Endod 2020; 47:215-220. [PMID: 33275995 DOI: 10.1016/j.joen.2020.11.024] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/27/2020] [Accepted: 11/23/2020] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Cracked teeth are a common clinical finding; however, their presence renders diagnosis and prognosis unreliable. The purpose of this research was to assess the correlations of multiple factors on the prognosis of cracked teeth that had undergone endodontic treatment. METHODS A total of 3680 patients who received endodontic treatment by an advanced postdoctoral education program in endodontics with follow-up records of at least 1 year were assessed. From this sample, 62 patients met the inclusion criteria and were included in the final analysis. The factors being evaluated included demographics, clinical symptoms and signs, radiographic findings, and restoration type. Statistical analysis was then completed using the chi-square and Fisher exact tests. RESULTS The mean follow-up period was 23.3 months, with an overall tooth success rate of 75.8%. The success rates differed significantly when the patient had an existing preoperative periapical lesion, lacked a proper permanent restoration on the treated tooth, or had a post placed after root canal treatment. Data analysis showed that restoring the tooth after endodontic treatment was the single most important factor for prognosis. In fact, the endodontically treated teeth with definitive full-coverage restorations had a 2-year success rate of 93.6%. CONCLUSION Full-coverage restorations should be considered an important part of the treatment plan for cracked teeth treated endodontically.
Collapse
Affiliation(s)
- Yen-Tung Chen
- Department of Endodontics, Boston University, Boston, Massachusetts
| | - Tun-Yi Hsu
- Department of Endodontics, Boston University, Boston, Massachusetts
| | - Hongsheng Liu
- Department of Endodontics, Boston University, Boston, Massachusetts
| | - Sami Chogle
- Department of Endodontics, Boston University, Boston, Massachusetts.
| |
Collapse
|
24
|
Influence of Metal Post in Adjacent Teeth in the Detection of Vertical Root Fracture Using Cone-beam Computed Tomography with Different Acquisition Parameters. J Endod 2020; 46:1655-1661. [PMID: 32835757 DOI: 10.1016/j.joen.2020.08.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/12/2020] [Accepted: 08/10/2020] [Indexed: 11/23/2022]
Abstract
INTRODUCTION The aim of the present study was to evaluate the detection of vertical root fracture (VRF) in the presence of adjacent teeth restored with a metal post and the influence of acquisition parameters (tube current and metal artifact reduction [MAR] algorithm) on this diagnostic task. METHODS Cone-beam computed tomographic images of 10 single-rooted teeth were acquired before and after the simulation of VRF. The acquisitions were set up to simulate different conditions regarding the presence of adjacent teeth restored with a metal post (control, 1 adjacent tooth, and both adjacent teeth), different tube currents (4, 8, and 10 mA), and the use of MAR (without MAR and with MAR). Images were assessed by 5 oral and maxillofacial radiologists using a 5-point scale for the presence of VRF. Diagnostic values were calculated and compared by 2-way analysis of variance (significance level of 5%). RESULTS The area under the receiver operating characteristic curve (Az) values for VRF detection were affected by the presence of adjacent teeth and the variation of milliamperes. For 4 mA, when both restored teeth were present, Az values were significantly lower than the control group (P ≤ .05). In the presence of both restored teeth, 8 mA presented significantly higher Az values compared with 4 mA (P ≤ .05). CONCLUSIONS The presence of both adjacent teeth restored with a metal post impairs VRF detection; however, an increase in tube current up to 8 mA may aid in this diagnostic task. Moreover, the MAR tool does not seem to be efficient in those cases.
Collapse
|
25
|
Mazzi-Chaves JF, de Faria Vasconcelos K, Pauwels R, Jacobs R, Sousa-Neto MD. Cone-beam Computed Tomographic-based Assessment of Filled C-shaped Canals: Artifact Expression of Cone-beam Computed Tomography as Opposed to Micro-computed Tomography and Nano-computed Tomography. J Endod 2020; 46:1702-1711. [PMID: 32682791 DOI: 10.1016/j.joen.2020.07.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 07/05/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The present study investigated the assessment of root canal fillings in a series of cone-beam computed tomographic (CBCT) images obtained from endodontically treated mandibular molars with C-shaped canals. METHODS Clinically comparable high (HR) and normal (NR) resolution protocols were selected in 3D Accuitomo 170 (J Morita Corporation, Kyoto, Japan), NewTom VGi evo (Cefla QR Verona, Verona, Italy), ProMax 3D Max (Pro; Planmeca, Helsinki, Finland), and Pax-i3D Green Premium (Pax; Vatech, Gyeonggi, South Korea). Micro-computed tomographic and nano-computed tomographic images were considered as the reference standard. The set of images was evaluated according to beam hardening artifact patterns (dark streaks, hypodense areas, and volume distortion). RESULTS Regarding dark streaks, the Fleiss kappa test showed that Pax HR and NR and Pro HR images showed the highest artifact expression. Hypodense areas were detected in 100% and 99.1% of the images obtained using Pax HR and NR, respectively. Kappa tests showed highest distortion for images derived from the Pax and Pro CBCT devices. Root canal filling assessment was considered appropriate in 100% of the 3D Accuitomo 170 HR, NewTom VGi evo NR, micro-computed tomographic, and nano-computed tomographic images. CONCLUSIONS The present study confirms the large variability in CBCT-derived artifact expression. Highlighting the increased artifact expression for particular CBCT systems, it may be concluded that for diagnosis of endodontically filled molars with C-shaped canals, the choice of CBCT unit and protocol is essential.
Collapse
Affiliation(s)
- Jardel Francisco Mazzi-Chaves
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil; Oral and Maxillofacial Surgery, Imaging and Pathology Research Group, Faculty of Medicine, Department of Imaging and Pathology, University of Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Karla de Faria Vasconcelos
- Oral and Maxillofacial Surgery, Imaging and Pathology Research Group, Faculty of Medicine, Department of Imaging and Pathology, University of Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Ruben Pauwels
- Oral and Maxillofacial Surgery, Imaging and Pathology Research Group, Faculty of Medicine, Department of Imaging and Pathology, University of Leuven, University Hospitals Leuven, Leuven, Belgium; Aarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark; Faculty of Dentistry, Department of Radiology, Chulalongkorn University, Bangkok, Thailand
| | - Reinhilde Jacobs
- Oral and Maxillofacial Surgery, Imaging and Pathology Research Group, Faculty of Medicine, Department of Imaging and Pathology, University of Leuven, University Hospitals Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Manoel Damião Sousa-Neto
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
| |
Collapse
|
26
|
Effect of digital enhancement on the radiographic assessment of vertical root fractures in the presence of different intracanal materials: an in vitro study. Clin Oral Investig 2020; 25:195-202. [PMID: 32506327 DOI: 10.1007/s00784-020-03353-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 05/19/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES To evaluate the effect of enhancement tools of intraoral digital radiographs on the assessment of vertical root fracture (VRF) and to quantify the resultant image noise. MATERIALS AND METHODS Thirty single-rooted human teeth (15 control and 15 fractured) were each radiographed in four intracanal conditions: no filling, gutta-percha, metal post, and fiberglass post, totaling 120 original images. Two filters were applied to the original images-Sharpen filter (SF) and Edge Enhancement filter (EE), and brightness and contrast were adjusted in four combinations (B&C1 to 4), resulting in 840 images. Five oral radiologists analyzed the images for VRF detection. Pixel intensity was obtained in two regions from the radiographs. Diagnostic values were calculated and compared by two-way ANOVA, and the SD values of pixel intensity values were compared by one-way ANOVA (α = 0.05). RESULTS There were no significant differences in accuracy for VRF detection between the experimental groups (p > 0.05). Teeth with metal post presented the lowest sensitivity (p < 0.05) for all experimental conditions, except for SF and EE (p > 0.05). B&C2, B&C3, and B&C4 had higher specificity than SF (p ≤ 0.05) for all intracanal conditions. Analysis of pixel intensity showed that all enhanced images presented statistically significant higher noise compared to those of the original images (p ≤ 0.05). CONCLUSION Digital enhancement tools in digital radiography increase image noise; however, they can be used without compromising VRF detection. CLINICAL RELEVANCE The use of digital enhancement does not impair the detection of VRF and, therefore, can be applied for this purpose according to the observer preference.
Collapse
|
27
|
Camargo RV, Mazzi-Chaves JF, Leoni GB, Vasconcelos KF, Lamira A, Jacobs R, Sousa-Neto MD. Quantitative Assessment of 2-dimensional Parameters in Tomographic Images by Using Different Segmentation Methods. J Endod 2020; 46:694-699. [DOI: 10.1016/j.joen.2020.01.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 01/14/2020] [Accepted: 01/19/2020] [Indexed: 10/24/2022]
|
28
|
Nascimento EHL, Fontenele RC, Santaella GM, Freitas DQ. Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant. Dentomaxillofac Radiol 2019; 48:20190058. [PMID: 31276425 DOI: 10.1259/dmfr.20190058] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVES To quantify the artefacts production and the performance of the metal artefact reduction (MAR) tool, enabled before or after the acquisition, in cortical plates (buccal and lingual) and other regions adjacent to zirconium implants. METHODS Cone beam CT scans were acquired using the OP300 Maxio unit before (control group) and after (implant group) the insertion of a zirconium implant into the posterior region of a dry mandible. Three conditions of MAR tool were tested: "without MAR", with "MAR activated after acquisition", and with "MAR activated before acquisition". The standard deviation (SD), contrast-to-noise ratio (CNR) and voxel values were calculated in the buccal and lingual cortical plates, medullary bone and water region, close to the implant. The structural bone analysis was performed in the medullary bone close to the implant. RESULTS Overall, in control and implant groups, the lingual cortical had higher SD, lower CNR and lower voxel values than the buccal cortical, regardless of the MAR condition (p < 0.05). Implant caused higher SD values and lower voxel values in adjacent regions "without MAR" (p < 0.05). MAR activation decreased SD and changed voxel values when the implant was present, regardless of MAR activation mode (p < 0.05). The activation of MAR increased the trabecular thickness values for the implant group (p < 0.05). CONCLUSION The expression of artefacts adjacent to zirconium implants is greater in the lingual than in the buccal cortical. The greater the expression of artefacts in this region, the greater the effectiveness of the MAR tool in homogenizing the grey values, regardless of the time of its activation.
Collapse
Affiliation(s)
- Eduarda Helena Leandro Nascimento
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| | - Rocharles Cavalcante Fontenele
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| | - Gustavo Machado Santaella
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| |
Collapse
|
29
|
Diniz de Lima E, Lira de Farias Freitas AP, Mariz Suassuna FC, Sousa Melo SL, Bento PM, Pita de Melo D. Assessment of Cone-beam Computed Tomographic Artifacts from Different Intracanal Materials on Birooted Teeth. J Endod 2019; 45:209-213.e2. [PMID: 30711180 DOI: 10.1016/j.joen.2018.11.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 11/12/2018] [Accepted: 11/18/2018] [Indexed: 11/16/2022]
Abstract
INTRODUCTION This study quantitatively evaluated the type and amount of image artifacts generated by different intracanal materials in birooted teeth scanned at different exposure parameters. METHODS The sample consisted of 15 birooted premolars. Seven different intracanal material combinations were used in each tooth one at a time: (1) roots without intracanal materials, (2) roots with gutta-percha, (3) a buccal root with gutta-percha and a lingual root with a fiberglass post, (4) a buccal root with gutta-percha and a lingual root with a metal core fiberglass post, (5) buccal and lingual roots with fiberglass posts, (6) buccal and lingual roots with metal core fiberglass posts, and (7) buccal and lingual roots with NiCr metal posts. Cone-beam computed tomographic scans were acquired using a CS 9000 unit (Carestream Dental, Atlanta, GA). An image of each tooth was captured under 5 exposure parameters: 2.5, 4, 6.3, 8, and 12 mA. The voxel size, field of view, and tube voltage were fixed at 0.076 mm, 5 × 3.75 cm, and 75 kV. We assessed each artifact quantitatively using ImageJ's threshold tool (National Institutes of Health, Bethesda, MD) to determine the hypodense and hyperdense artifact areas within 8-bit images extracted from the scans. All analyses were conducted with a 95% confidence level (α <0.05). RESULTS The inferential analysis showed that roots filled with metal posts presented the highest amount of hypodense and hyperdense artifacts, whereas fiberglass post in both roots presented fewer artifacts. All materials presented more hypodense than hyperdense artifact formation. Overall, the low-exposure settings presented fewer artifacts and higher values of preserved dental images. CONCLUSIONS Low-exposure protocols and fiberglass posts presented fewer image artifacts in CBCT scans.
Collapse
Affiliation(s)
- Elisa Diniz de Lima
- Department of Dentistry, State University of Paraíba, Campina Grande, Paraiba, Brazil
| | | | | | - Saulo L Sousa Melo
- Department of Oral Pathology, Radiology and Medicine, The University of Iowa, Iowa City, Iowa
| | - Patricia Meira Bento
- Department of Dentistry, State University of Paraíba, Campina Grande, Paraiba, Brazil
| | - Daniela Pita de Melo
- Department of Dentistry, State University of Paraíba, Campina Grande, Paraiba, Brazil.
| |
Collapse
|
30
|
Byakova SF, Novozhilova NE, Makeeva IM, Grachev VI, Kasatkina IV. The accuracy of CBCT for the detection and diagnosis of vertical root fracturesin vivo. Int Endod J 2019; 52:1255-1263. [DOI: 10.1111/iej.13114] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Accepted: 03/07/2019] [Indexed: 12/14/2022]
Affiliation(s)
- S. F. Byakova
- Department of Therapeutic Dentistry Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University (Sechenov University) of the Ministry of Health of the Russian Federation MoscowRussia
| | - N. E. Novozhilova
- Department of Therapeutic Dentistry Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University (Sechenov University) of the Ministry of Health of the Russian Federation MoscowRussia
| | - I. M. Makeeva
- Department of Therapeutic Dentistry Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University (Sechenov University) of the Ministry of Health of the Russian Federation MoscowRussia
| | - V. I. Grachev
- Independent X‐ray diagnostic laboratory “3D Lab” MoscowRussia
| | - I. V. Kasatkina
- A.N. Frumkin Institute of Physical Chemistry and Electrochemistry RAS Moscow Russia
| |
Collapse
|
31
|
Freitas DQ, Vasconcelos TV, Noujeim M. Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography. Clin Oral Investig 2018; 23:1263-1270. [PMID: 29984377 DOI: 10.1007/s00784-018-2558-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 07/02/2018] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate the influence of artifacts produced by zirconium implant on the diagnosis of vertical root fracture (VRF) in teeth close and distant to the implant in cone beam computed tomography (CBCT) images. We also determined if kilovoltage (kVp) and metal artifact reduction (MAR) tool could influence this diagnosis. MATERIALS AND METHODS Twenty single-root teeth were divided in control and fractured groups (n = 10). The teeth were randomly positioned in the first and second and right and left pre-molar alveoli of a dry human mandible. CBCT exams were acquired using a ProMax 3D unit with varying kVp (70, 80, or 90 kVp), with or without MAR, and with and without a zirconium implant placed in the alveolus of first right molar. The images were evaluated by five observers. The area under the receiver operating characteristic curve (ROC), sensitivity, and specificity were calculated and compared by analysis of variance with a significance level of 5%. RESULTS In general, ROC and sensitivity were not affected by the factors studied (p > 0.05). The main effects occurred in specificity; when implant was used without MAR, the values were lower for tooth 45 for all kVps (p = 0.0001). CONCLUSIONS Artifacts produced in the vicinity of teeth with suspected VRF impair the diagnosis by decreasing the specificity, because they can mimic the VRF line generating false positives. However, MAR improves the specificity, being its use recommended when metallic objects are present near teeth with suspected VRF. CLINICAL RELEVANCE Since nowadays, many patients who undergo CBCT show implants and they definitively produce artifacts, it is important to evaluate the influence of such artifacts in the diagnosis of teeth that are close to the generator-artifact object.
Collapse
Affiliation(s)
- Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil.
| | - Taruska Ventorini Vasconcelos
- Division of Oral Radiology, School of Dentistry, Federal University of Bahia, Rua Araújo Pinho, 62, Salvador, Bahia, 40110-040, Brazil
| | - Marcel Noujeim
- Department of Comprehensive Dentistry, Division of Oral and Maxillofacial Radiology, University of Texas Health Science Center at San Antonio, 7707, Floyd Curl Drive, San Antonio, TX, 78229, USA
| |
Collapse
|
32
|
Wanderley VA, Freitas DQ, Haiter-Neto F, Oliveira ML. Influence of Tooth Orientation on the Detection of Vertical Root Fracture in Cone-beam Computed Tomography. J Endod 2018; 44:1168-1172. [DOI: 10.1016/j.joen.2018.04.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 03/18/2018] [Accepted: 04/02/2018] [Indexed: 10/14/2022]
|