de Bastos RS, da Silva TV, Vieira VTL, Silva EJNL. Evaluation of mechanical properties of an original and a replica-like reciprocating instruments. AUST ENDOD J 2024; 50:486-492. [PMID: 38747371 DOI: 10.1111/aej.12854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/04/2024] [Accepted: 05/06/2024] [Indexed: 12/13/2024]
Abstract
This study assessed the mechanical properties of the Only One File Blue and the Reciproc Blue instruments. A total of 80 new 25 mm reciprocating NiTi instruments (25/.08v) were evaluated for their mechanical performance (n = 40 per group). Cyclic fatigue resistance, torsional fatigue, flexural resistance and buckling resistance tests were conducted. Statistical analysis was employed with a significance level set at 5%. The results indicated no statistically significant differences in resistance to cyclic fatigue neither in the fragment length between the instruments (p > 0.05). However, the Reciproc Blue instrument exhibited greater torque to fracture and a larger rotation angle than the Only One File Blue instrument (p < 0.05). The Only One File Blue instrument demonstrated higher flexibility but lower resistance to buckling compared to the Reciproc Blue instrument (p < 0.05). In conclusion, the tested instruments exhibit differences in mechanical properties, with the Reciproc Blue instrument generally presenting greater advantages than the Only One File Blue.
Collapse
|
2
|
Romeo VR, La Rosa GRM, Generali L, Pedullà E, Angerame D. Influence of different kinematics on shaping ability and accumulated hard tissue debris: an ex vivo study. Odontology 2024:10.1007/s10266-024-01025-w. [PMID: 39585498 DOI: 10.1007/s10266-024-01025-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Accepted: 11/11/2024] [Indexed: 11/26/2024]
Abstract
To determine the shaping ability, the amount of accumulated hard tissue debris (AHTD) and untouched area is generated by different kinematics through micro-CT. Thirty-two mesial roots of mandibular molars with Vertucci type IV were pre-scanned through micro-CT evaluation and randomized to one of the four experimental groups according to the kinematics tested: Continuous Rotation (CR), Reciprocation (REC), Optimum Torque Reverse (OTR) and Jeni motion. The root canal preparation was performed with HyFlex EDM (Coltène/Whaledent AG) up to OneFile. After each file used, irrigation was performed with 2 mL 5.25% NaOCl for 1 min. The final rinse was performed with 1 ml of 5.25% NaOCl followed by a 1 ml of 17% EDTA and, 1 ml of distilled water. Then, the samples were scanned and the images, before and after preparation, were superimposed and analyzed to determine the AHTD, untouched areas, canal transportation, centering ability, and shaping time. Data were statistically analyzed using Kruskal-Wallis test and Dunn post hoc with p < 0.05. No significant differences were detected among the tested kinematics in terms of untouched areas, AHTD, canal transportation and shaping time (p > 0.05). Significantly more untouched areas were detected in the coronal third compared to the middle (p = 0.0301) and apical ones (p = 0.0399) under continuous rotation. Moreover, a significantly higher centering ratio in the middle third compared to the apical was observed for Jeni motion (p = 0.0207). The tested kinematics showed similar untouched areas, AHTD, shaping ability and shaping time. All motions determined an appropriate mechanical preparation; yet, none of them was able to prepare all canal walls and keep the root canals completely free from hard tissue debris.
Collapse
Affiliation(s)
- Virginia Rosy Romeo
- Department of General Surgery and Medical Surgical Specialties, University of Catania, Catania, Italy
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical Surgical Specialties, University of Catania, Catania, Italy.
| | - Luigi Generali
- Unit of Dentistry and Oral-Maxillo-Facial Surgery, Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance, University of Modena and Reggio Emilia, Modena, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical Surgical Specialties, University of Catania, Catania, Italy
| | - Daniele Angerame
- Clinical Department of Medical Science, Surgery and Health, University of Trieste, Trieste, Italy
| |
Collapse
|
3
|
Martins JNR, Silva EJNL, Marques D, Versiani MA. Influence of Continuous Rotation and Optimal Torque Reverse Kinematics on the Cyclic Fatigue Strength of Endodontic NiTi Clockwise Cutting Rotary Instruments. Dent J (Basel) 2024; 12:317. [PMID: 39452445 PMCID: PMC11506770 DOI: 10.3390/dj12100317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2024] [Revised: 09/24/2024] [Accepted: 09/29/2024] [Indexed: 10/26/2024] Open
Abstract
Objectives: The objective of the present study was to evaluate the cyclic fatigue strength of clockwise cutting rotary endodontic instruments when subjected to two different kinematics: continuous clockwise rotation and clockwise reciprocation movement under optimum torque reverse (OTR) motion. Methods: New ProTaper Next X1 (n = 20) and X2 (n = 20) instruments were randomly divided into two subgroups (n = 10) based on kinematics (continuous rotation or OTR). The specimens were tested using a custom-made device with a non-tapered stainless-steel artificial canal measuring 19 mm in length, featuring a 6 mm radius and an 86-degree curvature. All instruments were tested with a lubricant at room temperature until a fracture occurred. The time to fracture and the length of the separated fragment were recorded. Subsequently, the fractured instruments were inspected under a scanning electron microscope for signs of cyclic fatigue failure, plastic deformation, and/or crack propagation. The subgroup comparisons for time to fracture and instrument length were performed using the independent samples t-test, with the level of statistical significance set at 0.05. Results: When using OTR movement, the ProTaper Next X1 increased the time to fracture from 52.9 to 125.8 s (p < 0.001), while the ProTaper Next X2 increased from 45.4 to 66.0 s (p < 0.001). No subgroup exhibited plastic deformations, but both showed dimpling marks indicative of cyclic fatigue as the primary mode of failure. Additionally, OTR movement resulted in more metal alloy microcracks. Conclusions: The use of OTR motion extended the lifespan of the tested instruments and resulted in a higher number of metal microcracks. This suggests that OTR motion helped to distribute the mechanical stress more evenly across the instrument, thereby relieving localized tension. As a result, it delayed the formation of a single catastrophic crack, enhancing the overall performance of the instruments during the experimental procedures.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Emmanuel J. N. L. Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
- Department of Endodontics, Fluminense Federal University, Rio de Janeiro 24220-900, Brazil
- Department of Endodontics, Rio de Janeiro University (UERJ), Rio de Janeiro 20550-013, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Marco A. Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte 30350-190, Brazil
| |
Collapse
|
4
|
Subramanian SK, Joshi V, Kalra S, Adhikari S. Unveiling the fatigue life of NiTi endodontic files: An integrated computational-experimental study. J Mech Behav Biomed Mater 2024; 157:106657. [PMID: 39024733 DOI: 10.1016/j.jmbbm.2024.106657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 07/03/2024] [Accepted: 07/07/2024] [Indexed: 07/20/2024]
Abstract
Nickel-titanium (NiTi) rotary files used in root canal treatments experience fatigue and shear damage due to the complex curved geometries and operating conditions encountered within the root canal. This can lead to premature file fracture, causing severe complications. A comprehensive understanding of how different factors contribute to file damage is crucial for improving their functional life. This study investigates the combined effects of root canal curvature radius, file canal curvature, and rotational speed on the fatigue life and failure modes of NiTi endodontic files through an integrated computational and experimental approach. Advanced finite element simulations precisely replicating the dynamic motion of files inside curved canal geometries were conducted. Critical stress/strain values were extracted and incorporated into empirical fatigue models to predict the functional life of endodontic files. Extensive experiments with files rotated inside artificial curved canals at various canal curvatures and speeds provided validation. Increasing the canal curvature beyond 60∘ and shorter curvature radii below 5 mm dramatically reduced the functional life of the endodontic file, especially at rotational speeds over 360 rpm. The Coffin-Manson fatigue model based on strain amplitude showed the closest agreement with experiments. Shear stresses dominated damage at low canal curvatures, while the combined shear-fatigue loading effects were prominent at higher canal curvatures. This conclusive study elucidates how operational parameters like canal curvature radii, canal curvature, and rotational speed synergistically influence the fatigue damage processes in NiTi files. The findings offer valuable guidelines to optimize these factors, significantly extending the functional life of endodontic files and reducing the risk of intra-operative failures. The validated computational approach provides a powerful tool for virtual testing and estimation of the functional life of the new file designs before manufacturing.
Collapse
Affiliation(s)
| | - Vivek Joshi
- Department of Mechanical Engineering, Indian Institute of Technology Jammu, India.
| | - Sahil Kalra
- Department of Mechanical Engineering, Indian Institute of Technology Jammu, India.
| | - Sondipon Adhikari
- James Watt School of Engineering, The University of Glasgow, Glasgow G12 8QQ, UK.
| |
Collapse
|
5
|
Aydın U, Özdemir M, Çulha E, Baştürk Özer MN, Turan B. Evaluation of Cyclic Fatigue Resistance of Novel Replica-Like Instruments in Static Test Model. Appl Bionics Biomech 2024; 2024:8842478. [PMID: 39206445 PMCID: PMC11357823 DOI: 10.1155/2024/8842478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 08/06/2024] [Indexed: 09/04/2024] Open
Abstract
Introduction The aim of our study is to comparatively analyze the canal cyclic fatigue resistance of widely used rotary file systems, including EndoArt Touch Gold (ETG), Perfect MTF Plus Gold (PPG), Fanta V-Taper Gold (FVG), and ProTaper Next (PTN). Methods Stainless steel canals with a 60° angle and a 3-mm curvature radius were specially prepared. The canals were shaped with each rotary file system and tested for resistance using a cyclic fatigue testing apparatus. The number of fracture cycles (NFC; K file tip separation) was measured. Data were analysed by one-way ANOVA and post hoc LSD tests. Results PTN and PPG rotary file systems exhibited the highest NFC. The NFC value for PTN was 589 ± 63, and for PPG, it was 507 ± 51. Conclusion The results of this study demonstrate that rotary file systems such as PTN and PPG exhibit higher cyclic fatigue resistance. ETG and FVG rotary file systems also possess generally acceptable cyclic fatigue resistance levels.
Collapse
Affiliation(s)
- Uğur Aydın
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Melih Özdemir
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Emre Çulha
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | | | - Bilal Turan
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| |
Collapse
|
6
|
Ragozzini G, Abu Hasna A, dos Reis FAS, de Moura FB, Campos TMB, Bueno CES, Carvalho CAT, de Martin AS. Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments. Int J Dent 2024; 2024:6628146. [PMID: 38938694 PMCID: PMC11208808 DOI: 10.1155/2024/6628146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/31/2024] [Accepted: 05/22/2024] [Indexed: 06/29/2024] Open
Abstract
This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments' fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micro-Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi-square, one-way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4-Gold, and Roll-Wave-Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.
Collapse
Affiliation(s)
- Gustavo Ragozzini
- Faculdade São Leopoldo MandicInstituto de Pesquisas São Leopoldo Mandic, Endodontia, Campinas, São Paulo, Brazil
| | - Amjad Abu Hasna
- Department of Restorative DentistryEndodontics DivisionInstitute of Science and TechnologySão Paulo State University (ICT-UNESP), Eng. Francisco José Longo Avenue 777, São José dos Campos, São Paulo CEP 12245-000, Brazil
- School of DentistryUniversidad Espíritu Santo, Samborondón, Ecuador
| | | | - Felipe Bernardo de Moura
- Department of Restorative DentistryEndodontics DivisionInstitute of Science and TechnologySão Paulo State University (ICT-UNESP), Eng. Francisco José Longo Avenue 777, São José dos Campos, São Paulo CEP 12245-000, Brazil
| | | | | | - Cláudio Antonio Talge Carvalho
- Department of Restorative DentistryEndodontics DivisionInstitute of Science and TechnologySão Paulo State University (ICT-UNESP), Eng. Francisco José Longo Avenue 777, São José dos Campos, São Paulo CEP 12245-000, Brazil
| | - Alexandre Sigrist de Martin
- Faculdade São Leopoldo MandicInstituto de Pesquisas São Leopoldo Mandic, Endodontia, Campinas, São Paulo, Brazil
| |
Collapse
|
7
|
Martins JNR, Silva EJNL, Marques D, Braz Fernandes FM, Versiani MA. Comprehensive Assessment of Cyclic Fatigue Strength in Five Multiple-File Nickel-Titanium Endodontic Systems. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2345. [PMID: 38793413 PMCID: PMC11123240 DOI: 10.3390/ma17102345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/02/2024] [Accepted: 05/09/2024] [Indexed: 05/26/2024]
Abstract
The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Emmanuel J. N. L. Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
- Department of Endodontics, Fluminense Federal University, Rio de Janeiro 24220-900, Brazil
- Department of Endodontics, Rio de Janeiro University (UERJ), Rio de Janeiro 20550-013, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Francisco M. Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Marco A. Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte 30350-190, Brazil
| |
Collapse
|
8
|
Dos Reis FAS, Abu Hasna A, Ragozzini G, de Moura FB, Campos TMB, de Martin AS, Carvalho CAT, Bueno CES. Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue. Sci Rep 2023; 13:22956. [PMID: 38151487 PMCID: PMC10752872 DOI: 10.1038/s41598-023-50096-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 12/15/2023] [Indexed: 12/29/2023] Open
Abstract
This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey's test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.
Collapse
Affiliation(s)
| | - Amjad Abu Hasna
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil.
- School of Dentistry, Universidad Espíritu Santo, Samborondón, Ecuador.
| | - Gustavo Ragozzini
- Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Endodontia, Campinas, SP, Brazil
| | - Felipe Bernardo de Moura
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil
| | | | | | - Cláudio Antonio Talge Carvalho
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil
| | | |
Collapse
|
9
|
dos Reis FAS, Abu Hasna A, Ragozzini G, de Moura FB, Campos TMB, de Martin AS, Carvalho CAT, Bueno CES. Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue. Sci Rep 2023; 13:22956. [DOI: https:/doi.org/10.1038/s41598-023-50096-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 12/15/2023] [Indexed: 01/17/2024] Open
Abstract
AbstractThis study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey’s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.
Collapse
|
10
|
Chan WS, Gulati K, Peters OA. Advancing Nitinol: From heat treatment to surface functionalization for nickel–titanium (NiTi) instruments in endodontics. Bioact Mater 2023; 22:91-111. [PMID: 36203965 PMCID: PMC9520078 DOI: 10.1016/j.bioactmat.2022.09.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/04/2022] [Accepted: 09/09/2022] [Indexed: 11/27/2022] Open
Abstract
Nickel-titanium (NiTi) alloy has been extensively researched in endodontics, particularly in cleaning and shaping the root canal system. Research advances have primarily focused on the design, shape, and geometry of the NiTi files as well as metallurgy and mechanical properties. So far, extensive investigations have been made surrounding surface and thermomechanical treatments, however, limited work has been done in the realm of surface functionalization to augment its performance in endodontics. This review summarizes the unique characteristics, current use, and latest developments in thermomechanically treated NiTi endodontic files. It discusses recent improvements in nano-engineering and the possibility of customizing the NiTi file surface for added functionalization. Whilst clinical translation of this technology has yet to be fully realized, future research direction will lie in the use of nanotechnology. Nitinol (Nickel Titanium alloy) is widely used to clean/shape root canal system in endodontics. To enhance its performance, various thermo-mechanical and nano-engineering modifications have been performed. This comprehensive review summarizes the latest advances and future trends relating to functionalized NiTi endodontic files.
Collapse
|
11
|
Thu M, Ebihara A, Maki K, Nishijo M, Kimura S, Nakatsukasa T, Kyaw MS, Okiji T. Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments. BMC Oral Health 2022; 22:617. [PMID: 36529721 PMCID: PMC9761994 DOI: 10.1186/s12903-022-02639-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND To evaluate the effect of pecking motions with faster upward speed on the dynamic cyclic fatigue resistance of nickel-titanium rotary instruments with different metallurgy. METHODS Forty each of ProTaper Universal F3 (PTU) and ProTaper Gold F3 (PTG) instruments (size #30/.09) were equally divided into four groups. The test was performed using an 18-mm-long stainless steel artificial canal with a 5-mm radius of curvature, a 45° canal curvature and a 2-mm canal diameter. A downward speed of 100 mm/min was employed, while the upward speed was set at 100, 150, 200 or 300 mm/min. Time to failure (Tf), number of cycles to failure (Nf) and number of pecking motions to failure (Np) were recorded. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests for Tf, Nf, and Np (α = 0.05). RESULTS The 100/300 mm/min group showed significantly higher Np values than the 100/100 mm/min group (p < 0.05), whereas there were no significant differences in Tf and Nf among the tested speed groups (p < 0.05) in either PTU or PTG. PTG exhibited significantly higher Tf, Nf, and Np than PTU (p < 0.05). CONCLUSIONS Under the tested conditions, the fastest upward speed group showed significantly higher cyclic fatigue resistance, as demonstrated by larger Np, than the same speed group. PTG had significantly higher cyclic fatigue resistance than PTU in all groups.
Collapse
Affiliation(s)
- Myint Thu
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Arata Ebihara
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Keiichiro Maki
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Miki Nishijo
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Shunsuke Kimura
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Taro Nakatsukasa
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Moe Sandar Kyaw
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Takashi Okiji
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| |
Collapse
|
12
|
Moreira EJL, Silva EJNL, Belladonna FG, Maciel AC, Vieira VTL, De-Deus G. Mechanical performance of original; yellowish and blueish ProFile instruments: isolating heat-treatment as a variable. Braz Dent J 2022; 33:47-53. [PMID: 36043568 DOI: 10.1590/0103-6440202204978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Accepted: 06/23/2022] [Indexed: 11/21/2022] Open
Abstract
The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min. After reaching the programmed temperatures of 450 ºC or 500 ºC the system remained at a constant temperature for 10 minutes; followed by cooling in water at room temperature. Afterwards; the three groups (n=30 per group) of instruments were compared regarding their cyclic fatigue (n=10 per group); bending (n=10 per group); and buckling resistance (n=10 per group). After cyclic fatigue tests; a scanning electron microscope was used to analyze the fracture surfaces and observe the fracture mode. Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls test; with an alpha type error set at 0.05. Yellowish and blueish coloration was observed in the ProFile instruments after 450 ºC or 500 ºC heat treatments; respectively. Conventional ProFile instruments showed the lower cyclic fatigue; and the higher bending and buckling resistance (P<0.05). In contrast; yellowish ProFile instruments (heat treated at 500° C) showed the higher cyclic fatigue; and the lower bending and buckling resistance (P>0.05). It can be concluded that the different heat treatments performed on ProFile instruments increased its cyclic fatigue resistance and improved the flexibility and buckling resistance.
Collapse
Affiliation(s)
- Edson J L Moreira
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| | - Emmanuel J N L Silva
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| | - Felipe G Belladonna
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| | - Ana Carolina Maciel
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| | - Victor T L Vieira
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| | - Gustavo De-Deus
- Department of Endodontics; Fluminense Federal University (UFF); Niterói; RJ; Brazil
| |
Collapse
|
13
|
Uslu O, Haznedaroglu F, Keskin C. Comparison of mechanical resistance and standardisation between original brand and replica-like endodontic systems. AUST ENDOD J 2022; 49:149-158. [PMID: 35703893 DOI: 10.1111/aej.12639] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 04/11/2022] [Accepted: 05/16/2022] [Indexed: 11/30/2022]
Abstract
This study compared the original (ProTaper Next and Reciproc) endodontic systems with their replica-like brands (X File and Only One File) in terms of standardisation, design, phase-transformation behaviour, composition and mechanical behaviour. X File showed greater taper values than ProTaper Next, while Only One File had the greatest tip diameter. Both replica-like files had an active tip and greater dimensions than their reports. There were also significant differences between the original and replica-like systems in terms of their phase-transformation behaviour and the precision of the measurement lines. Only One File showed significantly lower cyclic fatigue and torsional resistance than Reciproc (p < 0.05). There were no significant differences in the cyclic fatigue, torsional resistance and composition of NiTi between X File and ProTaper Next (p > 0.05). Although replica systems show mechanical properties that can be acceptable, they are not consistent in terms of standardisation and design.
Collapse
Affiliation(s)
- Orkun Uslu
- Department of Endodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.,Institute of Graduate Studies in Health Sciences, Istanbul University, Istanbul, Turkey
| | - Faruk Haznedaroglu
- Department of Endodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | - Cangül Keskin
- Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| |
Collapse
|
14
|
What meaningful information are the instruments mechanical testing giving us? A comprehensive review. J Endod 2022; 48:985-1004. [PMID: 35667567 DOI: 10.1016/j.joen.2022.05.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 04/21/2022] [Accepted: 05/26/2022] [Indexed: 11/22/2022]
Abstract
Instruments mechanical strength and flexibility are traditionally tested by running cyclic fatigue, torsional, bending, buckling and microhardness tests. Several cyclic fatigue test models have been used in endodontics, all capable of providing a curved trajectory for the instrument to rotate. The cyclic fatigue testing allowed to identify conditions that may affect the fatigue strength outcomes, such as canal radius and degree of curvature, handpiece static vs dynamic motions, test temperature, kinematics, instrument previously wear and sterilization cycles, or instrument's size and metal alloy features. Due to the international test specifications for both torsional and bending tests, the variations of their models are not as many as for cyclic fatigue. These tests have also identified conditions capable of affecting the outcomes, such as kinematics, instrument's preloading, cross-sectional diameters, or alloy heat treatments. Buckling and microhardness are less common, with the metal alloy being considered to have a major influence on the results. Instruments mechanical testing, having all these individual conditions as independent variables, allowed to understand them and moulded the way the technical procedures are performed clinically. Even though the artificiality and simplicity of these tests will hardly mimic real working situations, and independently of being capable of producing cornerstone knowledge, these tests are also associated with inconsistency, lack of reproducibility and low external validity. Several attempts have been made to increase the generalizability of the outcomes by adding test settings that intend to mimic the clinical condition. Although pertinent, these settings may also add variabilities inherent to their concepts and practical applications in the laboratory environment. Although the actual studies should be seen as laboratory mechanical tests that measure very specific parameters under very particular conditions and that by far do not mimic the clinical condition, the lower validity drawback seems to be possible to be minimized when achieving a comprehensive understanding of the instrument behaviour. A Finite Elements Method and/or a multimethod research approach may lead to superior data collection, analysis, and results' interpretation, which when associated with a reliable confounding factors control and proper study designs may be helpful tools and strategies in order to increase the reliability of the outcomes.
Collapse
|
15
|
Faus-Matoses V, Faus-Llácer V, Ruiz-Sánchez C, Jaramillo-Vásconez S, Faus-Matoses I, Martín-Biedma B, Zubizarreta-Macho Á. Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue-An In Vitro Study. J Clin Med 2022; 11:jcm11113143. [PMID: 35683530 PMCID: PMC9181116 DOI: 10.3390/jcm11113143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 05/23/2022] [Accepted: 05/30/2022] [Indexed: 11/22/2022] Open
Abstract
The present study aims to evaluate and contrast the function of the rotational speed of NiTi alloy endodontic rotary files on how resistant they are to dynamic cyclic fatigue. Methods: A total of 150 NiTi alloy endodontic rotary files with similar geometrical design and metallurgical properties were randomly divided into study groups: Group A: 200 rpm (n = 30); Group B: 350 rpm (n = 30); Group C: 500 rpm (n = 30); Group D: reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion (350 rpm+) (n = 30); and Group E: reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion (400 rpm+) (n = 30). A dynamic device was designed to carry out dynamic cyclic fatigue tests using artificial root canal systems made from stainless steel with an apical diameter of 250 µm, 5 mm radius of curvature, 60° curvature angle, and 6% taper, and 20 mm in length. A Weibull statistical analysis and ANOVA test were used to analyze the results. Results: The ANOVA analysis showed differences in time to failure among all the study groups that were of statistical significance (p < 0.001). Conclusions: NiTi alloy endodontic rotary files using reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion exhibit greater resistance to dynamic cyclic fatigue than files used with a reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion, continuous rotational speed at 200 rpm, continuous rotational speed at 350 rpm, or continuous rotational speed at 500 rpm; it is therefore advisable to use reciprocating movements at a low speed.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (V.F.-L.); (C.R.-S.); (S.J.-V.)
| | - Vicente Faus-Llácer
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (V.F.-L.); (C.R.-S.); (S.J.-V.)
| | - Celia Ruiz-Sánchez
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (V.F.-L.); (C.R.-S.); (S.J.-V.)
| | - Sharon Jaramillo-Vásconez
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (V.F.-L.); (C.R.-S.); (S.J.-V.)
| | - Ignacio Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (V.F.-L.); (C.R.-S.); (S.J.-V.)
- Correspondence:
| | - Benjamín Martín-Biedma
- Department of Surgery and Medical-Surgical Specialties, School of Medicine and Dentistry, Universidad de Santiago de Compostela, 15705 Santiago de Compostela, Spain;
| | - Álvaro Zubizarreta-Macho
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain;
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain
| |
Collapse
|
16
|
Faus-Matoses V, Pérez García R, Faus-Llácer V, Faus-Matoses I, Alonso Ezpeleta Ó, Albaladejo Martínez A, Zubizarreta-Macho Á. Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19074414. [PMID: 35410096 PMCID: PMC8998441 DOI: 10.3390/ijerph19074414] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 02/04/2023]
Abstract
In this study, we compare and analyze the scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), morphometry and cyclic fatigue resistance of Endogal, PathMax, and Smarttrack novel brands of nickel−titanium (NiTi) alloy endodontic files. Material and Methods: Thirty sterile NiTi endodontic rotary files were randomly selected and assigned to one of the following study groups: A: 25.08 F2 Endogal (EDG) (n = 10); B: 25.08 F2 Path Max Pro (PMP) (n = 10); and C: 25.06 Smarttrack (ST) (n = 10). Dynamic cyclic fatigue tests were conducted using a cyclic fatigue device in stainless steel artificial root canal systems with an apical diameter of 250 µm, curvature angle of 60°, radius of curvature of 3 mm, and taper of 6%. Additionally, we analyzed the NiTi endodontic rotary files using EDX, SEM, and morphometry after micro-CT scanning. The results were analyzed using Weibull statistical analysis and ANOVA testing. Results: SEM, EDX, and morphometric analyses showed differences between the three novel brands of NiTi endodontic rotary files. Moreover, statistically significant differences were observed between the number of cycles to failure and time to failure of the three novel brands of NiTi endodontic rotary files (p < 0.001). Conclusions: Smarttrack NiTi alloy endodontic reciprocating files display greater resistance to cyclic fatigue than Endogal and Path Max Pro NiTi alloy endodontic rotary files, due to the reciprocating movement and metallurgical composition.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Raúl Pérez García
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Vicente Faus-Llácer
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Ignacio Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
- Correspondence:
| | - Óscar Alonso Ezpeleta
- Department of Endodontics, School of Health Sciences, University of Zaragoza, 22006 Zaragoza, Spain;
| | - Alberto Albaladejo Martínez
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
| | - Álvaro Zubizarreta-Macho
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
- Department of Endodontics, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain
| |
Collapse
|
17
|
Kyaw MS, Ebihara A, Maki K, Kimura S, Nakatsukasa T, Htun PH, Thu M, Omori S, Okiji T. Effect of kinematics on the torque/force generation, surface characteristics, and shaping ability of a nickel titanium rotary glide path instrument: an ex-vivo study. Int Endod J 2022; 55:531-543. [PMID: 35263803 DOI: 10.1111/iej.13718] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 03/01/2022] [Accepted: 03/01/2022] [Indexed: 11/30/2022]
Abstract
AIM To evaluate the effect of various rotational motions on the torque/force generation, surface wear, and shaping ability of the ProGlider glide path instrument (Dentsply Sirona). METHODOLOGY Mesiobuccal and mesiolingual canals of mandibular molars were selected based on the canal volume, length, angle of curvature (25°-40°), and radius of curvature (4-8 mm) after micro-computed tomographic scanning. The samples were randomly assigned to four groups (n = 13, each) according to movement kinematics [continuous rotation (CR; 300 rpm), optimum torque reverse motion (OTR; 180° forward and 90° reverse when torque > 0.4 N·cm), time-dependent reciprocal motion (TmR; 180° forward and 90° reverse), and optimum glide path motion (OGP; a combination of 90° forward, 90° reverse, 90° forward, and 120° reverse)]. Instrumentation was performed with an automated root canal instrument and torque/force analysing device. Maximum torque/force values, canal volume changes, and canal-centring ratios at 1, 3, 5, and 7 mm were evaluated. Surface defects (pits, grooves, microcracks, blunt cutting edges, and disruption of cutting edges) and spiral distortion on the ProGlider instrument were scored at the tip and 5 mm short of the tip before and after five consecutive uses with scanning electron microscopy. The Kruskal-Wallis test followed by Dunn's post-test with Bonferroni correction and Wilcoxon signed-rank test were used to analyse the data (α = 0.05). RESULTS OGP generated significantly less clockwise torque and greater upward force than other groups (P < 0.05). OGP resulted in significantly fewer surface defects than CR (P < 0.05). In OGP and CR, the tip exhibited more surface defects than 5 mm short of the tip (P < 0.05). CR resulted in greater volume changes than OGP and TmR (P < 0.05) and greater centring ratios (i.e., more deviation) than OGP at 1 mm and OTR at 3 mm (P < 0.05). CONCLUSIONS Under laboratory conditions using the ProGlider instrument, OGP generated significantly less clockwise torque and greater upward force than the other rotatory motions. OGP generated fewer superficial defects than CR, and the three modes of reciprocal rotation better maintained the apical curvature of root canals than CR with the ProGlider instrument.
Collapse
Affiliation(s)
- M S Kyaw
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.,Department of Conservative Dentistry, University of Dental Medicine (Mandalay), Mandalay, Myanmar
| | - A Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - K Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - S Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - T Nakatsukasa
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - P H Htun
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - M Thu
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - S Omori
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - T Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| |
Collapse
|
18
|
Evolution and development: engine-driven endodontic rotary nickel-titanium instruments. Int J Oral Sci 2022; 14:12. [PMID: 35181648 PMCID: PMC8857196 DOI: 10.1038/s41368-021-00154-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/06/2021] [Accepted: 12/20/2021] [Indexed: 11/08/2022] Open
Abstract
Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
Collapse
|
19
|
Martins JNR, Marques D, Vasconcelos I, Arantes-Oliveira S, Caramês J, Braz Fernandes FM. Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments. Dent J (Basel) 2022; 10:dj10020030. [PMID: 35200255 PMCID: PMC8870709 DOI: 10.3390/dj10020030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/03/2022] Open
Abstract
Background: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. Methods: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyzed by stereomicroscopy and scanning electron microscopy, including the number of blades, helical angle means, cross-sectional design, surface finishing, and symmetry. Energy-dispersive X-ray spectroscopy was used determine the nickel/titanium elements ratio, and differential scanning calorimetry determined the instruments’ phase transformation temperatures. The cyclic fatigue tests were conducted in an artificial canal with a 6 mm radius and 86 degrees of curvature. The Mood’s median test and one-way ANOVA were used to determine differences, with the significance level set at 0.05. Results: The ProGlider presented the highest number of blades (n = 21), while R-Pilot had the highest helical angles (26.4°). Differences were noted in the instruments’ cross-sections and surface finishing. The ProGlider and R-Pilot showed some similarities regarding the phase transformation temperatures but differed from the Edge Glide Path. All alloys showed an almost equiatomic nickel/titanium ratio. The R-Pilot instruments showed a significantly higher (p < 0.05) time to fracture than both the other files. Conclusion: Reciprocating R-Pilot instruments showed a higher cyclic fatigue time to fracture than the ProGlider and Edge Glide Path rotary files.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
- Implantology Institute, 1070-064 Liaboa, Portugal
- Correspondence:
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
- Implantology Institute, 1070-064 Liaboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - Isabel Vasconcelos
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Center for Rapid and Sustainable Product Development, Polytechnic Institute of Leiria, 2411-901 Leiria, Portugal
| | - Sofia Arantes-Oliveira
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - João Caramês
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Implantology Institute, 1070-064 Liaboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - Francisco Manuel Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal;
| |
Collapse
|
20
|
Metallurgical Tests in Endodontics: A Narrative Review. Bioengineering (Basel) 2022; 9:bioengineering9010030. [PMID: 35049739 PMCID: PMC8773015 DOI: 10.3390/bioengineering9010030] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/07/2022] [Accepted: 01/11/2022] [Indexed: 11/17/2022] Open
Abstract
Since there are no reviews of the literature on this theme, the aim of this narrative review is to summarize the metallurgical tests used in endodontics, pointing out their functional use and their pros and cons and giving readers a user-friendly guide to serve as an orientation aid in the plethora of metallurgical tests. With this purpose, a literature search for articles published between January 2001 and December 2021 was conducted, using the electronic database PubMed to collect all published articles regarding the metallurgical tests used in endodontics for the evaluation of NiTi rotary instruments. The search was conducted using the following keywords: “metallurgy”, “differential scanning calorimetry” (DSC), “X-ray diffraction” (XRD), “atomic force microscopy” (AFM), “energy-dispersive X-ray spectroscopy” (EDS), “focused ion beam analysis” (FIB) and “Auger electron spectroscopy” (AES) combined with the term “endodontics” or “NiTi rotary instruments”. Considering the inclusion and exclusion criteria, of the 248 articles found, only 81 were included in the narrative review. According to the results, more than 50% of the selected articles were published in one of the two most relevant journals in endodontics: International Endodontic Journal (22.2%) and Journal of Endodontics (29.6%). The most popular metallurgical test was DSC, with 43 related articles, followed by EDS (33 articles), AFM (22 articles) and XRD (21 articles). Few studies were conducted using other tests such as FIB (2 articles), micro-Raman spectroscopy (4 articles), metallographic analysis (7 articles) and Auger electron spectroscopy (2 articles).
Collapse
|
21
|
Martins JNR, Silva EJNL, Marques D, Belladonna FG, Simões-Carvalho M, da Costa RP, Ginjeira A, Braz Fernandes FM, Versiani MA. Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation-a multimethod research. Clin Oral Investig 2021; 26:3299-3310. [PMID: 34860307 DOI: 10.1007/s00784-021-04311-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 11/20/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. MATERIAL AND METHODS A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. RESULTS Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 °C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P < .05). No significant difference was noted regarding the untouched root canal walls after preparation with the tested systems (P > .05). CONCLUSIONS Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems. CLINICAL RELEVANCE Root canal preparation systems with similar geometries might present different mechanical behaviors but equivalent shaping ability.
Collapse
Affiliation(s)
- Jorge N R Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal.
- Grupo de Investigação Em Bioquimica E Biologia Oral, Faculdade de Medicina Dentária, Unidade de Investigação Em Ciências Orais E Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal.
- Centro de Estudo de Medicina Dentária Baseada Na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.
| | - Emmanuel João Nogueira Leal Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Rio de Janeiro, Brazil
- Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal
- Grupo de Investigação Em Bioquimica E Biologia Oral, Faculdade de Medicina Dentária, Unidade de Investigação Em Ciências Orais E Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal
- Centro de Estudo de Medicina Dentária Baseada Na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, Lisbon, Portugal
| | | | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | - Rui Pereira da Costa
- Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal
| | - António Ginjeira
- Faculdade de Medicina Dentária, Universidade de Lisboa, Cidade Universitária, 1649-003, Lisbon, Portugal
- Grupo de Investigação Em Bioquimica E Biologia Oral, Faculdade de Medicina Dentária, Unidade de Investigação Em Ciências Orais E Biomédicas (UICOB), Universidade de Lisboa, Lisbon, Portugal
| | - Francisco Manuel Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | - Marco Aurélio Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
22
|
Nino-Barrera J, Sanchez-Aleman J, Acosta-Humanez M, Gamboa-Martinez L, Cortes-Rodriguez C. Shot peening increases resistance to cyclic fatigue fracture of endodontic files. Sci Rep 2021; 11:12961. [PMID: 34155287 PMCID: PMC8217493 DOI: 10.1038/s41598-021-92382-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 06/09/2021] [Indexed: 11/09/2022] Open
Abstract
The objective of this study was to assess the resistance to fatigue fracture of conventional nickel–titanium files after undergoing shot peening. Forty NITIFLEX endodontic files, number 30, were divided into two groups; one was submitted to shot peening treatment and the other was not. All instruments were tested for fatigue fracture in simulated canals with a TRI-AUTO ZX endodontic motor. One file of each group was subjected to a residual stress analysis by XRD. Finally, the fractured surface was observed and elemental analysis performed by means of SEM and EDX. Roughness analysis was made by focal variation microscope. The shot peening group showed greater resistance to fatigue fracture; there was no difference in the length of the fractured fragments. XRD results showed the presence of residual compression stresses in the file submitted to shot peening, a decrease in the interplanar spacing, and an increase in the full-width-at-half-maximum and the microstrains. SEM and EDX showed a ductile fracture with zones of fatigue and an equiatomic ratio between the nickel and titanium. Surface roughness increased after the file was subjected to the shot peening procedure. In conclusion, shot peening increases the resistance to fatigue fracture due to the presence of residual compression stresses in files manufactured from a conventional nickel–titanium alloy.
Collapse
Affiliation(s)
- Javier Nino-Barrera
- Faculty of Dentistry, Endodontics Program, Universidad Nacional de Colombia, Building 210, Office 301, Bogotá, Colombia.
| | - Jose Sanchez-Aleman
- Faculty of Dentistry, Endodontics Program, Universidad Nacional de Colombia, Building 210, Office 301, Bogotá, Colombia
| | | | - Luis Gamboa-Martinez
- School of Dentistry, Endodontics Program, Universidad El Bosque, Bogotá, Colombia
| | | |
Collapse
|
23
|
Martins JNR, Silva EJNL, Marques D, Belladonna F, Simões-Carvalho M, Vieira VTL, Antunes HS, Braz Fernandes FMB, Versiani MA. Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments. Int Endod J 2021; 54:1623-1637. [PMID: 33829516 DOI: 10.1111/iej.13529] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 04/05/2021] [Indexed: 11/28/2022]
Abstract
AIM To compare six reciprocating instruments regarding their geometric design, metallurgical characteristics, mechanical behaviour and ability to prepare root canals. METHODOLOGY A total of 246 new 25-mm NiTi instruments (41 per group) from six reciprocating systems (Reciproc, Reciproc Blue, One Files, One Files Blue, Reverso Silver, and WaveOne Gold) were evaluated throughout a multimethod approach regarding their design using stereomicroscopy (number of blades and helix angle) and scanning electron microscopy (blades symmetry, cross section and surface finishing), nickel-titanium composition, phase transformation temperatures, mechanical performance (cyclic fatigue, torsional and bending resistance) and unprepared canal surface area on anatomically matched mandibular molars assessed by micro-CT. One-way ANOVA and post hoc Tukey's or Mood's median tests were selected depending on sample distribution with significance level set at 5%. RESULTS The instruments had similarities regarding their metal composition and unprepared canal area, whilst differences in phase transformation temperatures and geometric design (number of blades, surface finishing and tip geometry) were observed. Overall, no difference was observed regarding the maximum torque values (P > 0.05), whilst One Files (72 s) and One Files Blue (414 s) had the shortest and longest times to fracture, respectively (P < 0.05). Similar angles of rotation were observed in Reciproc (310°), One Files (285°) and Reverso Silver (318°) instruments (P > 0.05), which were significantly lower than Reciproc Blue (492°), One Files Blue (456°) and WaveOne Gold (492°; P < 0.05). Maximum bending load demonstrated that Reciproc Blue (201.3 gf) was significantly more flexible that the other instruments (P < 0.05). CONCLUSION Although there were similarities in metal composition and percentage of unprepared canal surface, the instruments had differences in the overall geometric design, phase transformation temperatures and in the four mechanical resistance parameters (time to fracture, maximum torque, angle of rotation and maximum bending load).
Collapse
Affiliation(s)
- J N R Martins
- Department of Endodontics, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal
| | - E J N L Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil.,Department of Endodontics, Fluminense Federal University, Niteroi, Brazil
| | - D Marques
- Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,LIBPhys-FCT UID/FIS/04559/2013, Lisboa, Portugal
| | - F Belladonna
- Department of Endodontics, Fluminense Federal University, Niteroi, Brazil
| | - M Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niteroi, Brazil
| | - V T L Vieira
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - H S Antunes
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - F M B Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | - M A Versiani
- Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil
| |
Collapse
|
24
|
Moreira EJL, Antunes HDS, Vieira VTL, Cavalcante DM, Oliveira HE, Oliveira DDS, DE-Deus G, Silva EJNLD. Effects of clinical use of NiTi reciprocating instruments on cyclic and torsional resistance, and on roughness. Braz Oral Res 2021; 35:e021. [PMID: 33605352 DOI: 10.1590/1807-3107bor-2021.vol35.0021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 10/08/2020] [Indexed: 11/22/2022] Open
Abstract
The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey's test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.
Collapse
Affiliation(s)
- Edson Jorge Lima Moreira
- Universidade Federal Fluminense - UFF, School of Dentistry , Department of Endodontics , Niterói , RJ , Brazil
| | - Henrique Dos Santos Antunes
- Universidade do Grande Rio - Unigranrio, School of Dentistry , Department of Endodontics , Rio de Janeiro , RJ , Brazil
| | - Victor Talarico Leal Vieira
- Universidade do Grande Rio - Unigranrio, School of Dentistry , Department of Endodontics , Rio de Janeiro , RJ , Brazil
| | - Daniele Moreira Cavalcante
- Universidade Federal Fluminense - UFF, School of Dentistry , Department of Endodontics , Niterói , RJ , Brazil
| | - Henrique Eduardo Oliveira
- Universidade Federal Fluminense - UFF, School of Dentistry , Department of Endodontics , Niterói , RJ , Brazil
| | - Diogo da Silva Oliveira
- Universidade Federal Fluminense - UFF, School of Dentistry , Department of Endodontics , Niterói , RJ , Brazil
| | - Gustavo DE-Deus
- Universidade Federal Fluminense - UFF, School of Dentistry , Department of Endodontics , Niterói , RJ , Brazil
| | | |
Collapse
|
25
|
Martins JNR, Silva EJNL, Marques D, Belladonna F, Simões-Carvalho M, Camacho E, Braz Fernandes FM, Versiani MA. Comparison of design, metallurgy, mechanical performance and shaping ability of replica-like and counterfeit instruments of the ProTaper Next system. Int Endod J 2021; 54:780-792. [PMID: 33300121 DOI: 10.1111/iej.13463] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 12/06/2020] [Accepted: 12/07/2020] [Indexed: 11/30/2022]
Abstract
AIM To compare the ProTaper Next (PTN) system with a replica-like and a counterfeit system regarding design, metallurgy, mechanical performance and shaping ability. METHODOLOGY Replica-like (X-File) and counterfeit (PTN-CF) instruments were compared to the PTN system regarding design (microscopy), phase transformation temperatures (differential scanning calorimetry), nickel-titanium ratio (energy-dispersive X-ray spectroscopy), cyclic fatigue, torsional resistance, bending strength, and untouched canal areas in extracted mandibular molars (micro-CT). anova, post hoc Tukey's and Kruskal-Wallis tests were used according to normality assessment (Shapiro-Wilk test) with the significance level set at 5%. RESULTS Overall similarities in design and nickel-titanium (Ni/Ti) ratio were observed amongst instruments with the X-File having a smoother surface finish. PTN and PTN-CF had mixed austenite plus R-phase (R-phase start approximately at 45 ºC and near 30 ºC, respectively), whilst X-File instruments were austenitic (R-phase started at approximately at 17 ºC) at room temperature (20 ºC). PTN-CF had the greatest inconsistency in the phase transformation temperatures. Time to fracture of PTN-CF X2 and X3 was significantly shorter than PTN and X-File instruments (P < 0.05), whilst no difference was noted in maximum torque to fracture amongst the tested systems (P > 0.05). X-Files and PTN-CF had a stress-induced phase change during bending load. Mean unprepared surface areas of root canals were 25.8% (PTN), 31.1% (X-File) and 32.5% (PTN-CF) with no significant difference amongst groups (P > 0.05). CONCLUSION Similarities amongst the systems were noted in the Ni/Ti ratio and maximum torque to fracture, whilst differences were observed in the design, phase transformation temperatures and mechanical behaviour. The ProTaper Next counterfeit instruments could be considered as the less secure system considering its low-cyclic fatigue resistance. Apart from these differences, the unprepared canal surface areas, obtained with the tested systems, were similar.
Collapse
Affiliation(s)
- J N R Martins
- Department of Endodontics, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal
| | - E J N L Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Rio de Janeiro, Brazil.,Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | - D Marques
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,LIBPhys-FCT UID/FIS/04559/2013, Lisboa, Portugal
| | - F Belladonna
- Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | - M Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | - E Camacho
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | - F M Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | - M A Versiani
- Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil
| |
Collapse
|
26
|
Abstract
OBJECTIVE The aim of this study was to evaluate the cyclic fatigue, torsional behavior and bending resistance of EdgeTaper Platinum [ETP (tip 25, taper 0.06)], Flex Gold [FG (tip 25, taper 0.08)], Pro-T [PT (tip 25, taper 0.08)] and ProTaper Gold [PTG (tip 25, taper 0.08)] systems. METHODS Rotary instruments of ETP, PT, FG, and PTG were used (n=30). Cyclic fatigue tests were performed using an artificial stainless-steel canal with a 60o angle and a 5-mm radius of curvature at body temperature (35°±1°C). The time and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). The bending test evaluated the torque required to bend the instruments at an angular deflection of 60°. Data were analyzed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. RESULTS The ETP had highest time until fracture and NCF than all the groups (P<0.05). The PTG had the highest torsional strength, followed by FG (P<0.05). The ETP had the highest angular rotation, followed by PT and PTG (P<0.05). The FG showed the highest bending resistance, followed by the PTG (P<0.05). CONCLUSION In conclusion, the ETP and PT exhibited higher cyclic fatigue resistance, higher angular deflection values and lower bending force than FG and PTG. The PTG instruments showed the highest torsional strength and the lowest cyclic fatigue resistance.
Collapse
|
27
|
Weissheimer T, Heck L, Calefi PHS, Alcalde MP, Rosa RA, Vivan RR, Duarte MAH, Só MVR. Evaluation of the mechanical properties of different nickel–titanium retreatment instruments. AUST ENDOD J 2020; 47:265-272. [DOI: 10.1111/aej.12474] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 10/27/2020] [Accepted: 11/21/2020] [Indexed: 11/27/2022]
Affiliation(s)
- Theodoro Weissheimer
- Department of Conservative Dentistry Federal University of Rio Grande do Sul Porto Alegre Brazil
| | - Luana Heck
- Department of Conservative Dentistry Federal University of Rio Grande do Sul Porto Alegre Brazil
| | - Pedro Henrique Souza Calefi
- Department of Operative Dentistry Endodontics and Dental Materials Bauru School of Dentistry University of São Paulo São Paulo Brazil
| | | | - Ricardo Abreu Rosa
- Department of Conservative Dentistry Federal University of Rio Grande do Sul Porto Alegre Brazil
| | - Rodrigo Ricci Vivan
- Department of Operative Dentistry Endodontics and Dental Materials Bauru School of Dentistry University of São Paulo São Paulo Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Operative Dentistry Endodontics and Dental Materials Bauru School of Dentistry University of São Paulo São Paulo Brazil
| | - Marcus Vinícius Reis Só
- Department of Conservative Dentistry Federal University of Rio Grande do Sul Porto Alegre Brazil
| |
Collapse
|
28
|
Martins JN, Silva EJ, Marques D, Pereira MR, Ginjeira A, Silva RJ, Braz Fernandes FM, Versiani MA. Mechanical Performance and Metallurgical Features of ProTaper Universal and 6 Replicalike Systems. J Endod 2020; 46:1884-1893. [DOI: 10.1016/j.joen.2020.08.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/25/2020] [Accepted: 08/29/2020] [Indexed: 11/29/2022]
|