1
|
Waitayagitgumjon K, Poocharoen W, Trirongjitmoah S, Treeprapin K, Suttiwongsing A, Wirifai T, Trirongchitmoh C, Tangkabuanbutr P. A Multicenter Pilot Study of Biliary Atresia Screening Using Digital Stool Color Imaging. Pediatr Gastroenterol Hepatol Nutr 2024; 27:168-175. [PMID: 38818277 PMCID: PMC11134179 DOI: 10.5223/pghn.2024.27.3.168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/29/2024] [Accepted: 03/15/2024] [Indexed: 06/01/2024] Open
Abstract
Purpose The presence of alcoholic stool in biliary atresia (BA) patients is the basis of a stool color card (SCC), a screening tool that has led to more patients receiving Kasai portoenterostomy earlier. This study aimed to evaluate the color image processing of stool images captured using smartphones. We propose that measuring digital color parameters is a more objective method for identifying BA stools and may improve the sensitivity of BA screening. Methods A prospective study was conducted in five hospitals in Thailand between October 1, 2020, and December 31, 2021. Stools from infants presenting with jaundice, acholic stool, or dark-colored urine were photographed. Digital image color analysis was performed, and software was developed based on the color on the original SCC. Sensitivity and specificity for predicting BA stools were compared between the SCC and the software. Results Of 33 infants eligible for data collection, 19 were diagnosed with BA. Saturation and blue were two potential digital color parameters used to differentiate BA stools. The receiver operating characteristic curve was used to determine the optimum cutoff point of both values, and when saturation ≤56 or blue ≥61 was set as a threshold for detecting BA stool, high accuracy was achieved at 81.8% and 78.8%, respectively. Conclusion Digital image processing is a promising technology. With appropriate cutoff values of saturation in hue, saturation, value and blue in red, green, blue color models, BA stools can be identified, and equivocal-colored stools of non-BA patients can be differentiated with acceptable accuracy in infants presenting with jaundice.
Collapse
Affiliation(s)
| | - Wannisa Poocharoen
- Department of Surgery, Queen Sirikit National Institute of Child Health, Ratchathewi, Bangkok, Thailand
- Department of Surgery, College of Medicine, Rangsit University, Bangkok, Thailand
| | - Suchin Trirongjitmoah
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Ubon Ratchathani University, Ubon Ratchathani, Thailand
| | - Kriengsak Treeprapin
- Department of Mathematics, Statistics and Computer, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, Thailand
| | - Arada Suttiwongsing
- Department of Surgery, Chiangrai Prachanukroh Hospital, Chiang Rai, Thailand
| | - Thetiya Wirifai
- Department of Surgery, Khon Kaen Hospital, Khon Kaen, Thailand
| | | | | |
Collapse
|
2
|
Arshad A, Gardiner J, Ho C, Rees P, Chadda K, Baker A, Sutcliffe AG. Population-based screening methods in biliary atresia: a systematic review and meta-analysis. Arch Dis Child 2023; 108:468-473. [PMID: 36797045 DOI: 10.1136/archdischild-2022-324946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 01/30/2023] [Indexed: 02/18/2023]
Abstract
OBJECTIVE The aim of this study was to investigate tested methods of population-based biliary atresia (BA) screening. DESIGN We searched 11 databases between 1 January 1975 and 12 September 2022. Data extraction was independently done by two investigators. MAIN OUTCOME MEASURES Our primary outcomes were: sensitivity and specificity of screening method in BA detection, age at Kasai, BA associated morbidity and mortality, cost-effectiveness of screening. RESULTS Six methods of BA screening were evaluated: stool colour charts (SCCs), conjugated bilirubin measurements, stool colour saturations (SCSs), measurements of urinary sulfated bile acids (USBAs), assessments of blood spot bile acids and blood carnitine measurements.In a meta-analysis, USBA was the most sensitive and specific, with a pooled sensitivity and specificity of 100.0% (95% CI 2.5% to 100.0%) and 99.5% (95% CI 98.9% to 99.8%) (based on one study). This was followed by conjugated bilirubin measurements: 100.0% (95% CI 0.0% to 100.0%) and 99.3% (95% CI 91.9% to 99.9%), SCS: 100.0% (95% CI 0.00% to 100.0%) and 92.4% (95% CI 83.4% to 96.7%), and SCC: 87.9% (95% CI 80.4% to 92.8%) and 99.9% (95% CI 99.9% to 99.9%).SCC reduced the age of Kasai to ~60 days, compared with 36 days for conjugated bilirubin. Both SCC and conjugated bilirubin improved overall and transplant-free survival. The use of SCC was considerably more cost-effective than conjugated bilirubin measurements. CONCLUSION Conjugated bilirubin measurements and SCC are the most researched and demonstrate improved sensitivity and specificity in detecting BA. However, their use is expensive. Further research into conjugated bilirubin measurements, as well as alternative methods of population-based BA screening, is required. PROSPERO REGISTRATION NUMBER CRD42021235133.
Collapse
Affiliation(s)
- Adam Arshad
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, London, UK
| | - Julian Gardiner
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, London, UK
| | - Carmen Ho
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, London, UK
| | - Philippa Rees
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, London, UK
| | - Karan Chadda
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, London, UK
| | - Alastair Baker
- Department of Paediatric Hepatology, Kings College Hospital, London, UK
| | - Alastair G Sutcliffe
- Population, Policy & Practice Department, UCL GOS Institute of Child Health, Institute of Child Health, London, UK
| |
Collapse
|
3
|
de Castro CM, Olivi P, de Freitas Araújo KC, Barbosa Segundo ID, Dos Santos EV, Martínez-Huitle CA. Environmental application of a cost-effective smartphone-based method for COD analysis: Applicability in the electrochemical treatment of real wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 855:158816. [PMID: 36115407 DOI: 10.1016/j.scitotenv.2022.158816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 09/11/2022] [Accepted: 09/12/2022] [Indexed: 06/15/2023]
Abstract
This study aims to develop a cheap method for the evaluation of quality of water or the assessment of the treatment of water by chemical oxygen demand (COD) measurements throughout the use of the HSV color model in digital devices. A free application installed on a smartphone was used for analyzing the images in which the colors were acquired before to be quantified. The proposed method was also validated by the standard and spectrophotometric methods, demonstrating that no significant statistical differences were attained (average accuracy of 97 %). With these results, the utilization of this smartphone-based method for COD analysis was used/evaluated, for first time, by treating electrochemically a real water matrix with substantial organic and salts content using BDD and Pt/Ti anodes. Aiming to understand the performance of both anodes, bulk experiments were performed under real pH by applying current densities (j) of 15, 30, and 60 mA cm-2. COD abatement results (which were achieved with this novel smart water security solution) clearly showed that different organic matter removal efficiencies were achieved, depending on the electrocatalytic material used as well as the applied current density (42 %, 45 %, and 85 % for Ti/Pt while 93 %, 97 % and total degradation for BDD by applying 15, 30, and 60 mA cm-2, respectively). However, when the persulfate-mediated oxidation approach was used, with the addition of 2 or 4 g Na2SO4 L-1, COD removal efficiencies were enhanced, obtaining total degradation with 4 g Na2SO4 L-1 and by applying 15 mA cm-2. Finally, this smartphone imaging-based method provides a simple and rapid method for the evaluation of COD during the use of electrochemical remediation technology, developing and decentralizing analytics technologies for smart water solutions which play a key role in achieving the Sustainable Development Goal 6 (SDG6).
Collapse
Affiliation(s)
- Cláudio M de Castro
- Departamento de Química da Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto - Universidade de São Paulo, Ribeirão Preto 14.040-901, Brazil; Instituto Federal de Educação, Ciência e Tecnologia do Triângulo Mineiro, Uberaba 38.064-790, Brazil
| | - Paulo Olivi
- Departamento de Química da Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto - Universidade de São Paulo, Ribeirão Preto 14.040-901, Brazil
| | | | | | - Elisama V Dos Santos
- Instituto de Química, Universidade Federal do Rio Grande do Norte, Natal 59.078-970, Brazil
| | | |
Collapse
|
4
|
Schreiber RA, Harpavat S, Hulscher JBF, Wildhaber BE. Biliary Atresia in 2021: Epidemiology, Screening and Public Policy. J Clin Med 2022; 11:jcm11040999. [PMID: 35207269 PMCID: PMC8876662 DOI: 10.3390/jcm11040999] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 02/05/2022] [Accepted: 02/09/2022] [Indexed: 12/12/2022] Open
Abstract
Biliary atresia (BA) is a rare newborn liver disease with significant morbidity and mortality, especially if not recognized and treated early in life. It is the most common cause of liver-related death in children and the leading indication for liver transplantation in the pediatric population. Timely intervention with a Kasai portoenterostomy (KPE) can significantly improve prognosis. Delayed disease recognition, late patient referral, and untimely surgery remains a worldwide problem. This article will focus on biliary atresia from a global public health perspective, including disease epidemiology, current national screening programs, and their impact on outcome, as well as new and novel BA screening initiatives. Policy challenges for the implementation of BA screening programs will also be discussed, highlighting examples from the North American, European, and Asian experience.
Collapse
Affiliation(s)
- Richard A. Schreiber
- Division of Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
- Correspondence: ; Tel.: +1-604-875-2332 (ext. 1); Fax: +1-604-875-3244
| | - Sanjiv Harpavat
- Division of Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, Baylor College of Medicine and Texas Children’s Hospital, Houston, TX 77030, USA;
| | - Jan B. F. Hulscher
- Department of Surgery, Division of Pediatric Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands;
| | - Barbara E. Wildhaber
- Swiss Pediatric Liver Center, Division of Pediatric Surgery, Department of Pediatrics, Gynecology, and Obstetrics, University of Geneva, 1205 Geneva, Switzerland;
| |
Collapse
|
5
|
Angelico R, Liccardo D, Paoletti M, Pietrobattista A, Basso MS, Mosca A, Safarikia S, Grimaldi C, Saffioti MC, Candusso M, Maggiore G, Spada M. A novel mobile phone application for infant stool color recognition: An easy and effective tool to identify acholic stools in newborns. J Med Screen 2020; 28:230-237. [PMID: 33241758 DOI: 10.1177/0969141320974413] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Early diagnosis of biliary atresia is essential to improve long-term outcomes. Newborn screening with an infant stool color card allows early recognition of biliary atresia patients. Our aim was to develop and validate a mobile phone application (PopòApp) able to identify acholic stools. METHODS An intuitive app was developed for iOS and Android smartphones. A learning machine process was used to generate an algorithm for stools color recognition based on the seven colors of the infant stool color card, which were considered as the gold standard. Consecutive images of stools were taken by the PopòApp, directly into the diapers of children aged ≤6 months. The PopòApp classified the photographs as "normal", "acholic" or "uncertain". To validate the PopòApp, four doctors independently classified all images, and only those for which all doctors agreed were included. The sensitivity, specificity, positive/negative predictive values, and accuracy of the PopòApp were evaluated. RESULTS Of 165 images collected, 160 were included in the study. All acholic stools were recognized by the PopòApp. The PopòApp sensitivity was 100% (95% CI:93.9%-100%) with no false negatives, regardless of the brand of phone. The specificity was 99.0% (95% CI:94.6%-99.9%). The accurancy of the PopòApp was 99.4% (95% CI:96.6%-99.9%), with a positive predictive value of 98.4% (95% CI:89.8%-99.8%). CONCLUSION The current study proved, in a large cohort, that the PopòApp is an accurate and easy tool for recognition of acholic stools. The mobile App may represent an effective strategy for the early referral of children with acholic stools, and potentially could improve the outcomes of biliary atresia.
Collapse
Affiliation(s)
- Roberta Angelico
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy.,Department of Surgical Science, HPB and Transplant Unit, University of Rome Tor Vergata, Rome, Italy
| | - Daniela Liccardo
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Monica Paoletti
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Andrea Pietrobattista
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Maria S Basso
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Antonella Mosca
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Samira Safarikia
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Chiara Grimaldi
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Maria C Saffioti
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Manila Candusso
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Giuseppe Maggiore
- Division of Gastroenterology, Hepatology and Nutrition, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Marco Spada
- Division of Abdominal Transplantation and Hepatobiliopancreatic Surgery, Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| |
Collapse
|
6
|
Abstract
Biliary atresia (BA) is a common cause of surgical jaundice during the neonatal period. It is currently considered as a spectrum of diseases with a common final pathology characterized by obliteration of the extrahepatic biliary tract and the absence of normally branching intrahepatic ducts. Though it is a global disease that can be found in all ethnicities there are some clear differences between BA arising in the East and the West. This is likely to be related to different genetic, environmental and cultural factors. BA is more frequently found in Far Eastern infants (both Chinese and Japanese) though the syndromic associations are much less common. Many Eastern countries have national screening programmes not seen in the West possibly due to debate over its cost effectiveness in countries where incidence is low. Kasai portoenterostomy (KPE) is considered as the primary treatment of BA but its outcome still remains unsatisfactory across the region. Given the complexity of BA, it is unlikely that strategic advances could be made by the sole effort of individual countries and we believe that collaboration between the East and West is the way forward.
Collapse
|
7
|
Shende P, Vaidya J, Kulkarni YA. Bio-inspired nano-engineered strip for semiquantitative FeNO analysis. J Breath Res 2019; 13:046002. [PMID: 31063980 DOI: 10.1088/1752-7163/ab1faf] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A point-of-care, non-invasive, low-cost and sensitive nano-biodiagnostic is needed in today's age for rapid and accurate self-diagnosis as well as for the management of asthma, which is advantageous for low resource areas where asthma is prevalent. The objective of this research work was to prepare the miniature, nanosponges coated paper strip to detect the asthma using certain biomarkers present in exhaled air. The asthma biomarker, nitric oxide present in exhaled air (FeNO) was chosen, which on reaction with nanosponges of diazotizing agent gave significant color change. The pyromellitic anhydride cross-linked β-cyclodextrin-based nanosponges of sulfanilamide and N-(1-naphthyl) ethylenediamine dihydrochloride were prepared using a polymer condensation method and coated on Whatman filter paper strip (1 × 5 cm2). The thickness of coating was found to be uniform (400 ± 50 μm) which was determined using SEM analysis. The Hue-Saturation-Value scale was used to detect the color change using a smartphone app. We also investigated the performance of a nano-engineered paper strip by comparing this with commercially available, FDA approved FeNO analyzer-NIOX MINO. Our findings demonstrated no significant difference in results obtained using both the techniques. Besides good repeatability, the paper strip showed increasing saturation with NO concentration and the capacity to detect the biomarker down to mean value of 20.33 ppb level. The successful validation and method comparison indicated that a bioinspired strip can provide on-site analysis and daily monitoring for diagnosis and management of asthma.
Collapse
Affiliation(s)
- Pravin Shende
- Shobhaben Pratapbhai Patel School of Pharmacy and Technology Management, SVKM's NMIMS, V.L. Mehta road, Vile Parle (W), Mumbai, India
| | | | | |
Collapse
|
8
|
Validity of an observational assessment tool for multifaceted evaluation of faecal condition. Sci Rep 2019; 9:3760. [PMID: 30842504 PMCID: PMC6403287 DOI: 10.1038/s41598-019-40178-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Accepted: 01/31/2019] [Indexed: 12/13/2022] Open
Abstract
Faecal volume, form, colour, and odour are associated with various diseases, dietary habits, and the gut microbiome. Multifaceted assessment of faecal condition will be needed for future research and practice. Faecal observation has advantages, as it is non-invasive, frequent, and easy. We have developed and validated an illustrative card tool for comprehensively faecal assessment. In 38 healthy adults, observations of volume, form, colour, and odour of faeces using the tool were compared to the objective characteristics of the actual faeces determined using a weighing scale, moisture meter, hardness meter, colourimeter, and odour measuring device. A significant positive correlation (ρ = 0.778) was observed between the number of faecal model (2 cm × 10 cm) units and the actual weight. The Bristol Stool Form Scale showed a significant positive correlation with the moisture content (ρ = 0.717) and negative correlations with faecal hardness (ρ = −0.843) and adhesiveness (ρ = −0.761). The L*a*b* colour space values of the stool differed significantly among observational judgments using the colour card tool. No significant correlation was observed between the observation of odour and the measured odour index. In conclusion, the faecal volume, form, and colour can be estimated by observation using the multifaceted assessment card tool.
Collapse
|
9
|
Province-wide Biliary Atresia Home Screening Program in British Columbia: Evaluation of First 2 Years. J Pediatr Gastroenterol Nutr 2018; 66:845-849. [PMID: 29570556 DOI: 10.1097/mpg.0000000000001950] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND OBJECTIVES Biliary atresia (BA), a rare newborn liver disease, is the leading cause of liver-related death in children. Early disease recognition and timely surgical Kasai hepatoportoenterostomy (KP) offers long-term survival without liver transplant. Universal BA screening in Taiwan using infant stool color cards (ISCCs) has proven effectiveness. We report our experience with infant stool color card (ISCC) BA screening in a province-wide program in British Columbia (BC). The objective of this study is to assess program performance and cost from launch April 1, 2014 to March 31, 2016. METHODS ISCCs distributed to families upon maternity ward discharge. Parents were instructed to monitor their infant's stool color for 1 month and contacted the screening center with concerns. The number of live births, ISCC distribution, BA cases, and costs were recorded. Cases with Program screen success had both acholic stool recognition (ISCC screen success) and timely referral for BA. RESULTS All 126 maternity units received ISCCs. Of 87,583 live births there were 6 BA cases. Of the 5 cases with ISCC Screen Success 3 had Program Screen Success. The median KP age in the program screen success and failure groups was 49 (42-52) and 116 (49-184) days, respectively. Program sensitivity was 50%, specificity 99%, positive predictive value 4%, and negative predictive value 99%. A random sample of 1054 charts at BC Children's Hospital found an ISCC distribution rate of 94%. After a phase-in period, the annual program cost was $30,033.82, and the ISCC cost per birth was $0.68. CONCLUSIONS The screening program has high specificity and distribution with low cost. Successful program case identification had earlier age at KP. Program modifications aim to improve sensitivity. Longer-term studies will determine program impact on health outcomes.
Collapse
|
10
|
Wang L, Yang Y, Chen Y, Zhan J. Early differential diagnosis methods of biliary atresia: a meta-analysis. Pediatr Surg Int 2018; 34:363-380. [PMID: 29397405 DOI: 10.1007/s00383-018-4229-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/11/2018] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the accuracy of early differential diagnosis methods of biliary atresia in patients with infantile cholestasis. METHODS We searched PubMed, EMBASE and the Web of Science databases for articles evaluated the early differential diagnosis methods of biliary atresia. The methodological quality of each study was assessed with version 2 of the Quality Assessment of Diagnostic Accuracy Studies tool. Two reviewers extracted data independently. Pooled sensitivity, specificity, positive likelihood ratio (LR +), negative likelihood ratio (LR -), diagnostic odds ratio (DOR) with 95% CIs were calculated to assess each diagnosis method. RESULTS A total of 38 articles were included. Summary sensitivity and specificity were 77% (95% CI 74-80%) and 93% (95% CI 91-94%), respectively, for B-US in 23 studies; 96% (95% CI 92-98%) and 58% (95% CI 51-65%), respectively, for MRCP in five studies; 87% (95% CI 82-91%) and 78% (95% CI 74-82%), respectively, for acholic stool in seven studies; 84% (95% CI 78-89%) and 97% (95% CI 97-98%), respectively, for serum liver function test in seven studies; 96% (95% CI 94-97%) and 73% (95% CI 70-76%), respectively, for hepatobiliary scintigraphy in 18 studies; 98% (95% CI 96-99%) and 93% (95% CI 89-95%), respectively, for percutaneous liver biopsy in 11 studies. CONCLUSION The accuracy rate of percutaneous liver biopsy is better than all of the noninvasive methods. Take into consideration the advantages and disadvantages of the six methods, combination of multidisciplinary noninvasive diagnosis methods is the first choice for differential diagnosis of BA from other causes of neonatal cholestasis.
Collapse
Affiliation(s)
- Li Wang
- Department of Pediatric Surgery, Tianjin Children's Hospital, Tianjin, 300134, China
| | - Yuan Yang
- Department of Pediatric Surgery, Tianjin Children's Hospital, Tianjin, 300134, China
| | - Yang Chen
- Department of Pediatric Surgery, Tianjin Children's Hospital, Tianjin, 300134, China
| | - Jianghua Zhan
- Department of Pediatric Surgery, Tianjin Children's Hospital, Tianjin, 300134, China.
- Tianjin Pediatrics Research Institute, Tianjin, 300134, China.
| |
Collapse
|