Murillo-Gómez F, Hernández-Víquez JR, Sauma-Montes de Oca JR, Vargas-Vargas C, González-Vargas N, Vega-Baudrit JR, Chavarría-Bolaños D. Mechanical, Adhesive and Surface Properties of a Zirconia-Reinforced Lithium Silicate CAD/CAM Ceramic Exposed to Different Etching Protocols. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5039. [PMID: 39459744 PMCID: PMC11509709 DOI: 10.3390/ma17205039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2024] [Revised: 10/09/2024] [Accepted: 10/12/2024] [Indexed: 10/28/2024]
Abstract
The aim of this investigation was to evaluate the effect of etching protocols on bond strength, surface roughness, and mechanical properties of a zirconia-reinforced lithium silicate (ZLS) CAD/CAM-ceramic. In total, 100 bars (ISO 6872), 75 plaques, and 25 cubes were cut from ZLS blocks(Vita Suprinity®). The surfaces were standardized, crystallized and divided into five groups: 1. control (no/treatment-C), 2. 5%-Hydrofluoric-acid (HF)/20 s (HF5%20s), 3.HF5%60s, 4.HF10%20s, and 5.HF10%60s. Flexural strength (FS) (three-point bending test, 1 mm/min), roughness (Pa), and micro-shear bond-strength (µSBS) tests were performed. The data were statistically analyzed with one-way ANOVA, Tukey's test (p ˂ 0.05) and Weibull (FS data). C showed higher Pa (1.176 ± 0.370 µm) than HF10%60s (0.627 ± 0.236 µm) and all other groups. Groups C and 20 s showed the most irregular surface patterns. The FS results were not influenced by etching protocols, while the Weibull modulus was, with the 5%HF groups being the most reliable (m: 5.63/6.70), while C and HF10%60s (m: 2.78/2.73) were the least reliable. All fractures originated from surface defects on the treated side of specimens. The 5%HF groups showed higher µSBS (20 s: 21.35 ± 4.70 MPa; 60 s: 23.50 ± 4.27 MPa) than the 10%HF groups (20 s: 14.51 ± 2.47 MPa; 60 s: 16.54 ± 3.12 MPa) and C (6.46 ± 2.71 MPa). The most prevalent failure pattern was "mixed" for etched groups, and "adhesive" for C. Etching protocols affect the evaluated properties by roughening materials' surface and, in some cases, regularizing surface defects. The best overall outcomes were achieved when applying 5%HF.
Collapse
Affiliation(s)
- Fabián Murillo-Gómez
- Restorative Dentistry Department, School of Dentistry-FOd, University of Costa Rica-UCR, San José 11502, Costa Rica
- Dental Materials Research Laboratory (LIMD), School of Dentistry-FOd, University of Costa Rica-UCR, San José 11502, Costa Rica
| | | | | | - Cristina Vargas-Vargas
- Restorative Dentistry Department, School of Dentistry-FOd, University of Costa Rica-UCR, San José 11502, Costa Rica
| | - Natalia González-Vargas
- Restorative Dentistry Department, School of Dentistry-FOd, University of Costa Rica-UCR, San José 11502, Costa Rica
| | - José Roberto Vega-Baudrit
- National Laboratory of Nanotechnology-LANOTEC, National Centre of High Technology-CENAT, San José 10109, Costa Rica;
| | - Daniel Chavarría-Bolaños
- Dentistry Graduate Program, University of Costa Rica-UCR, San José 11502, Costa Rica; (J.R.S.-M.d.O.); (D.C.-B.)
- National Laboratory of Nanotechnology-LANOTEC, National Centre of High Technology-CENAT, San José 10109, Costa Rica;
| |
Collapse
|
2
|
Nishizawa Y, Komagata Y, Nagamatsu Y, Kawamoto T, Ikeda H. Chemical etching of CAD-CAM glass-ceramic-based materials using fluoride solutions for bonding pretreatment. Dent Mater J 2024; 43:504-516. [PMID: 38825449 DOI: 10.4012/dmj.2023-333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
The surface treatment of glass-ceramic-based materials, namely, lithium disilicate glass (IPS e.max CAD), feldspar porcelain (VITABLOCS Mark II), and a polymer-infiltrated ceramic network (VITA ENAMIC), using aqueous fluoride solutions and their influence on luting agent bonding were investigated. Six experimental aqueous fluoride solutions were applied to these materials, and their effects were assessed by surface topological analysis. The obtained results were compared using non-parametric statistical analyses. Ammonium hydrogen fluoride (AHF) etchant demonstrated the greatest etching effect. Subsequent experiments focused on evaluating different concentrations of the AHF etchant for the bonding pretreatment of glass-ceramic-based materials with a luting agent (PANAVIA V5). AHF, particularly at concentrations above 5 wt%, effectively roughened the surfaces of the materials and improved the bonding performance. Notably, AHF at a concentration of 30 wt% exhibited a more pronounced effect on both etching and bonding capabilities compared to hydrofluoric acid.
Collapse
Affiliation(s)
- Yusaku Nishizawa
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
- Division of Orofacial Functions and Orthodontics, Department of Health Improvement, Kyushu Dental University
| | - Yuya Komagata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Tatsuo Kawamoto
- Division of Orofacial Functions and Orthodontics, Department of Health Improvement, Kyushu Dental University
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| |
Collapse
|
3
|
Calheiros-Lobo MJ, Carbas R, da Silva LFM, Pinho T. Impact of in vitro findings on clinical protocols for the adhesion of CAD-CAM blocks: A systematic integrative review and meta-analysis. J Prosthet Dent 2024; 131:1051-1070. [PMID: 36543700 DOI: 10.1016/j.prosdent.2022.08.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 12/23/2022]
Abstract
STATEMENT OF PROBLEM Computer-aided design and computer-aided manufacturing (CAD-CAM) blocks have evolved rapidly, making it difficult to establish the best clinical protocol for bonding a given block and whether an established protocol is appropriate for a newly introduced product. PURPOSE This integrative systematic review and meta-analysis aimed to clarify whether the clinician can select the most efficient adhesion protocols for CAD-CAM blocks by reading published in vitro studies and implementing them in daily practice. MATERIAL AND METHODS Based on the population, intervention, comparison, and outcome (PICO) strategy, 3 databases were searched for in vitro studies, randomized clinical trials, prospective or retrospective studies, and case reports from January 1, 2015, to July 31, 2021. A meta-analysis analyzed 28 studies to calculate the mean difference between best and worst protocols for each author and block with a random-effects model (α=.05). RESULTS From 508 relevant studies, 37 in vitro studies, 2 clinical studies, and 1 clinical report were selected for data extraction and qualitative analysis. Vita Enamic, IPS e.max CAD, LAVA Ultimate, and Vita Mark II blocks were the most studied, and RelyX Ultimate was the most used luting cement. The meta-analysis confirmed the null hypothesis that the evidence-based efficacy of clinical protocols to bond CAD-CAM blocks is still controversial (P<.05). CONCLUSIONS There are objective standards for individual in vitro tests, but the studies lack standardization. Some tested protocols were more efficient than others. Randomized clinical trials and well-documented clinical situations were almost nonexistent, making direct application of in vitro findings in clinical practice impossible.
Collapse
Affiliation(s)
- Maria João Calheiros-Lobo
- Clinical Professor, Department of Conservative Dentistry and Researcher, UNIPRO - Oral Pathology and Rehabilitation Research Unit, IUCS - CESPU, Gandra, Portugal.
| | - Ricardo Carbas
- Postdoctoral Researcher, INEGI - Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, Porto, Portugal
| | - Lucas F M da Silva
- Full Professor, Department of Mechanical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Teresa Pinho
- Full Professor and Researcher, UNIPRO - Oral Pathology and Rehabilitation Research Unit, IUCS - CESPU, Gandra, Portugal
| |
Collapse
|
4
|
Lima RBW, Muniz IDAF, Campos DES, Murillo-Gómez F, Andrade AKMD, Duarte RM, de Souza GM. Effect of universal adhesives and self-etch ceramic primers on bond strength to glass-ceramics: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2024; 131:392-402. [PMID: 35282935 DOI: 10.1016/j.prosdent.2022.01.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 12/28/2021] [Accepted: 01/04/2022] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM To simplify dental procedures, multicomponent products such as universal adhesives and self-etch ceramic primers have been recommended for glass-ceramic bonding; however, studies have shown a wide range of results. PURPOSE The purpose of this systematic review and meta-analysis was to analyze the in vitro bond strength promoted by hydrofluoric acid+silane-containing universal adhesives and a self-etch ceramic primer to glass-ceramics and compare it with that of conventional treatments. MATERIAL AND METHODS A systematic search was conducted in the PubMed/Medline, Scopus, LILACS, and ISI Web of Science databases up to April 2021. In vitro studies assessing the resin-mediated bond to glass-ceramics by using a self-etch ceramic primer and hydrofluoric acid+silane-containing universal adhesives and/or compared with traditional hydrofluoric acid+glass-ceramic primers were included. Selection of studies, data extraction, and risk-of-bias analysis were performed. Statistical analysis was performed by using a review management software program using a random effects model (α=.05). RESULTS A total of 33 studies were included in the qualitative analysis and 26 studies in the quantitative analysis. Bond strength to lithium disilicate ceramic was higher when a hydrofluoric acid+glass-ceramic primer was used than when using a hydrofluoric acid+silane-containing universal adhesive (P<.05), except when 9% to 10% acid concentration was used in combination with static aging (P=.100). A self-etch ceramic primer promoted bond strength values to lithium disilicate that were similar to those of the hydrofluoric acid+glass-ceramic primer (P>.100). CONCLUSIONS Hydrofluoric acid+silane-containing universal adhesive was not as effective as the hydrofluoric acid+glass-ceramic primer in promoting bond strength to glass-ceramic. Bond strength values generated by a self-etch ceramic primer to glass-ceramic were similar to those generated by the conventional treatment.
Collapse
Affiliation(s)
| | - Isis de Araújo Ferreira Muniz
- Doctoral student, Department of Restorative Dentistry, Federal University of Paraiba (UFPB), João Pessoa, Paraíba, Brazil
| | - Débora E Silva Campos
- Doctoral student, Department of Restorative Dentistry, Federal University of Paraiba (UFPB), João Pessoa, Paraíba, Brazil
| | - Fabián Murillo-Gómez
- Professor, Department of Restorative Dentistry, School of Dentistry, University of Costa Rica- UCR, San José, Costa Rica
| | - Ana Karina Maciel de Andrade
- Professor, Department of Restorative Dentistry, Federal University of Paraiba (UFPB), João Pessoa, Paraíba, Brazil
| | - Rosângela Marques Duarte
- Professor, Department of Restorative Dentistry, Federal University of Paraiba (UFPB), João Pessoa, Paraíba, Brazil
| | - Grace Mendonça de Souza
- Professor, Department of Clinical Sciences, Faculty of Dentistry, University of Toronto (UofT), Toronto, Ontario, Canada
| |
Collapse
|
5
|
Temp RW, Packaeser MG, Machry RV, Dapieve KS, Rippe MP, Pereira GKR, Valandro LF. Characteristic fatigue strength and reliability of dental glass-ceramics: Effect of distinct surface treatments - Hydrofluoric acid etching and silane treatment vs one-step self-etching ceramic primer. J Mech Behav Biomed Mater 2024; 150:106338. [PMID: 38159495 DOI: 10.1016/j.jmbbm.2023.106338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/14/2023] [Accepted: 12/16/2023] [Indexed: 01/03/2024]
Abstract
The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.
Collapse
Affiliation(s)
- Renatta Wrasse Temp
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Kiara Serafini Dapieve
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Marilia Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
6
|
Maqbool B, Rego HMC, Santos GC, Ari N, Santos MJMC. Effect of different surface treatment protocols on the bond strength between lithium disilicate and resin cements. Odontology 2024; 112:74-82. [PMID: 37036616 DOI: 10.1007/s10266-023-00809-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 03/24/2023] [Indexed: 04/11/2023]
Abstract
Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.
Collapse
Affiliation(s)
- Bilal Maqbool
- Schulich Medicine and Dentistry, Western University, London, ON, Canada
| | - Heleine Maria Chagas Rego
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, DSB, London, ON, N6A 5C1, Canada
| | - Gildo Coelho Santos
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, DSB, London, ON, N6A 5C1, Canada
| | - Nilgun Ari
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, London, ON, Canada
| | | |
Collapse
|
7
|
Turunç Oğuzman R, Şişmanoğlu S. Adhesive Performance of Resin Cement to Glass-Ceramic and Polymer-Based Ceramic CAD/CAM Materials after Applying Self-Etching Ceramic Primer or Different Surface Treatments. MATERIALS (BASEL, SWITZERLAND) 2023; 17:2. [PMID: 38203856 PMCID: PMC10780083 DOI: 10.3390/ma17010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/13/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024]
Abstract
Ensuring optimum bond strength during cementation is vital for restoration success, with the practicality of the process being crucial in clinical practice. This study analyzed the effect of a single-step self-etching ceramic primer (MEP) and various surface treatments on the microshear bond strength (µSBS) between resin cement and glass-ceramic or polymer-based ceramic CAD/CAM materials. Specimens were fabricated from leucite-based glass-ceramic (LEU), lithium disilicate glass-ceramic (LDC), resin nanoceramic (RNC), and polymer infiltrated ceramic network (PICN) (n = 160). They were then classified based on the surface treatments (n = 10): control (no treatment); sandblasting with Al2O3 (AL); etching with hydrofluoric acid (HF); and MEP application. Scanning electron microscopy was used to evaluate the surface topography. µSBS was measured after cementation and thermocycling procedures. Failure modes were examined with a stereomicroscope. Statistical analysis involved two-way analysis of variance and Tukey HSD tests with a significance level of 0.05. µSBS was significantly influenced by both surface treatment and CAD/CAM material type. The most enhanced µSBS values for each material, regarding the surface treatment, were: LEU and LDC, HF; RNC, AL; PICN, AL or HF. MEP significantly increased the µSBS values of CAD/CAM materials except RNC, yet it did not yield the highest µSBS values for any of them.
Collapse
Affiliation(s)
- Rana Turunç Oğuzman
- Department of Prosthodontics, Faculty of Dentistry, Altınbaş University, 34147 Istanbul, Turkey
| | - Soner Şişmanoğlu
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University-Cerrahpaşa, 34098 Istanbul, Turkey;
| |
Collapse
|
8
|
Tang T, Suputtamongkol K, Harnirattisai C, Neoh SP, Pongprueksa P. Interfacial fracture toughness of different surface treatments on zirconia-reinforced lithium silicate glass-ceramics. Dent Mater J 2023; 42:835-843. [PMID: 37880135 DOI: 10.4012/dmj.2023-124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
This study investigated the influence of different surface treatments on unfiring or firing zirconia-reinforced lithium silicate (ZLS) glass-ceramics. Celtra Duo and IPS e.max CAD blocks were cut and process following manufacturer protocols. The specimen surface was treated with seven different protocols. Two ceramic blocks with the same surface treatment were bonded with luting agent and prepared for mini-interfacial fracture toughness tests (mini-iFT). The specimens were tested after 1-week storage. The data was statistically analyzed using two-way ANOVA and Dunnett's T3 comparison (α=0.05). The highest mini-iFT of both Celtra Duo unfired and fired was shown in the HF+S group, which was not significantly different from HF+S+UA. For IPS e.max CAD, the mini-iFT was higher in the groups treated with hydrofluoric acid. Additional adhesive after silane application did not significantly improve bonding effectiveness. Therefore, surface treatment with hydrofluoric acid and silane is recommended for both unfiring and firing ZLS glass ceramics.
Collapse
Affiliation(s)
- Tianyu Tang
- Dental Biomaterials Science (International Programme), Faculty of Dentistry, Mahidol University
- School and Hospital of Stomatology, Kunming Medical University
| | | | | | - Siew Peng Neoh
- Department of Orthodontics, Faculty of Dentistry, Mahidol University
| | - Pong Pongprueksa
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University
| |
Collapse
|
9
|
Cheng PJ, Liu SM, Huang SM, Wang JC, Hung CC, Chen WC. Survival assessment of fractured porcelain-fused-to-metal crowns surface roughened by sandblasted and repaired by composite resin after in vitro thermal fatigue. J Dent Sci 2023; 18:1706-1715. [PMID: 37799887 PMCID: PMC10547947 DOI: 10.1016/j.jds.2023.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/02/2023] [Indexed: 01/15/2023] Open
Abstract
Background/purpose Intraoral repair usually takes the convenience of the patient's daily life as the starting point, taking into account the bonding strength, operational feasibility, and safety. This study aimed to evaluate the survival of composite resin by simulating cavity fracture repair in porcelain-fused-to-metal (PFM) crowns and referring to the G.V. Black classification of caries as ceramic- and metal-site exposure. Materials and methods Mechanical sandblast experimental and a nonsandblast control groups comprised 120 samples, and interfacial locking was enhanced through acid etching, bonding, and light-curing composite resin restoration. Classes of VI buccal (B), III mesial (M), and IV mesiobuccal (MB) types, were investigated. Load tests were performed on two sets, with one set at room temperature for 24 h and the other via thermal cycling at 5 °C/50 °C 720 times. Loading was gradually applied to the samples until a maximum of 450 N was reached. Results Results showed that 24 h survival rates of B-, M - , and MB-repaired PFM crowns were 88%, 84%, and 88%, respectively. The repaired PFM survival rates for B, M, and MB were 52%, 44%, and 28%, respectively, after thermal cycling and loading tests. Multiple logistic regression and chi-square test (α = 0.05) showed that the regression results of factors affecting survival assessment were only significant between groups after thermal fatigue (P < 0.05). Survival rate of repairing metal-site in the MB model was significantly higher than that of ceramic-sites repairing in non-blasted samples. For the MB cavity model, sandblasting can significantly improve the survival rate of the repair of ceramic parts in the MB model (P < 0.05). Conclusion Our results suggest that sandblasting can be further considered, especially for MB cavity fractures when ceramic-site restorations are required.
Collapse
Affiliation(s)
- Po-Jen Cheng
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
- Division of Dental Research, Department of Dentistry, Kaohsiung Municipal Min-Sheng Hospital, Kaohsiung, Taiwan
| | - Shih-Ming Liu
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
| | - Ssu-Meng Huang
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
| | - Jen-Chyan Wang
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chun-Cheng Hung
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Wen-Cheng Chen
- Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
10
|
Cardoso GC, Nakanishi L, Isolan CP, Rodrigues CS, Moraes RR. Bonding stability of universal adhesives to feldspathic ceramic with or without prior silane application. J Prosthodont 2023. [PMID: 37771238 DOI: 10.1111/jopr.13775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 09/01/2023] [Accepted: 09/23/2023] [Indexed: 09/30/2023] Open
Abstract
PURPOSE This study aimed to assess the bonding stability of three universal adhesives to a CAD-CAM feldspathic ceramic with or without prior silane application. MATERIALS AND METHODS The universal adhesives tested were Ambar Universal (FGM), Single Bond Universal (3M), and Ybond Universal (Yller). Scotchbond Multipurpose Plus (3M) was used as a control. The silane used was RelyX Ceramic Primer (3M). Microtensile bond strength (μTBS) to Vitablocs Mark II was measured after 24 h or 6 months of water aging (n = 20). Failure modes were observed through scanning electron microscopy, and pH and degree of C=C conversion (DC) of the adhesives were measured (n = 3). Data were analyzed using one-, two-, and three-way ANOVA. RESULTS The pH values differed significantly among the adhesives (p < 0.001), while the DC was similar (p = 0.141). The universal adhesives showed significant differences in μTBS, with higher immediate results when using silane and lower results after aging. Notably, a significant decrease in μTBS was observed after 6 months when silane was applied. In contrast, the control adhesive exhibited consistent results between the 24-h and 6-month storage periods. The universal adhesives showed a decrease in μTBS ranging from 25.5% to 40.1% after prolonged storage. Adhesive failures were predominant in all groups. The presence or absence of silane in the adhesive composition did not affect the bonding performance. CONCLUSIONS The application of a separate silane coupling agent improved the immediate bond strength of universal adhesives to CAD-CAM feldspathic ceramic. However, this bond strength significantly decreased after 6 months of water aging. The bond strength remained stable for universal adhesives when applied without silane after 6 months of aging.
Collapse
Affiliation(s)
- Gabriela C Cardoso
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Leina Nakanishi
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Cristina P Isolan
- School of Dentistry, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, Brazil
| | - Camila S Rodrigues
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Rafael R Moraes
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| |
Collapse
|
11
|
Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of surface treatments on optical, topographical and mechanical properties of CAD/CAM reinforced lithium silicate glass ceramics. Dent Mater 2023; 39:779-789. [PMID: 37438204 DOI: 10.1016/j.dental.2023.07.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/21/2023] [Accepted: 07/04/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVES To investigate the effect of different surface treatments on optical, topographical and mechanical properties of CAD/CAM lithium silicate-based glass ceramics (LSC's) and their combined effect on the output of a light curing unit (LCU). METHODS Four CAD/CAM LSC's were investigated: Lithium Disilicate (Emax CAD; EC), Zirconia-reinforced silicates (Vita Suprinity; VS and Celtra Duo;CD) and Lithium Aluminum Disilicate (CEREC Tessera; CT). Ceramic specimens (n = 240) were divided into six subgroups according to their surface treatment: (a) Control, (b) Hydrofluoric acid (HF) 5%, (c) HF 5% + Neutralizing agent (N), (d) HF 9%, (e) HF 9% +N and (f) Self-etching ceramic primer (SEP). Irradiance, power and radiant exposure of a LCU were measured with MARC-LC following ceramic specimen interposition. Direct light transmission (T%) and absorbance (Abs%) of the specimens were measured with UV-Vis spectrophotometry. Roughness (Sa, Sq) and wettability (θ°) were measured with optical profilometry and sessile drop profile analysis, respectively. Biaxial flexural strength (σ) of the ceramic specimens was measured by the ball-on-three-balls method and ceramic specimens were examined microscopically. Statistical analyses was performed by two-way ANOVA followed by post hoc multiple comparisons (α = 0.05). RESULTS Acid neutralization decreased T% and increased Abs% in all LSC's and highest T% was exhibited with VS. Neutralized EC, VS and CD displayed higher Sa in HF9, while neutralized CT displayed higher Sa in HF5. Self-etch primer significantly reduced θ° (p < 0.001). σ was observed in the followed ascending order: HF9 +N < HF9 < HF5 +N < HF5 < SEP < Control for all LSC's. SIGNIFICANCE Optical, topographical and mechanical properties of the CAD/CAM ceramic blocks were strongly dependent on the type of surface treatment. Results of neutralization post-etching indicate promising potential for future investigations.
Collapse
Affiliation(s)
- Hanan Al-Johani
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Restorative Dentistry, Division of Biomaterials, Faculty of Dentistry, King Abdulaziz University, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK.
| | | |
Collapse
|
12
|
Zahran M, Abo El-Farag S, Soltan H, Attia A. Fracture load of ultrathin occlusal veneers: Effect of thickness and surface conditioning. J Mech Behav Biomed Mater 2023; 145:106030. [PMID: 37473575 DOI: 10.1016/j.jmbbm.2023.106030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/12/2023] [Accepted: 07/15/2023] [Indexed: 07/22/2023]
Abstract
OBJECTIVE This in-vitro study is planned to analyze the effect of different thicknesses of ceramic occlusal veneers and different surface treatments on fracture resistance. MATERIALS AND METHODS A total of 48 sound mandibular molars are anatomically prepared from the occlusal surface with two different thicknesses (1.0 and 0.5 mm). CAD/CAM zirconia-reinforced glass ceramic blocks (Vita Suprinity) are used for fabricating occlusal veneers. The teeth are randomly divided into two primary groups A and B (n=24) according to occlusal veneer thickness. Each group is subdivided according to surface conditioning into three equal subgroups (n=8)-subgroup HF: etching with hydrofluoric acid and ceramic primer application; subgroup APF: etching with acidulated phosphate fluoride and ceramic primer application; subgroup EP: conditioning with etch and prime only. Dual-cure adhesive resin cement (Multilink Automix) is utilized to adhesively bond the veneers. All specimens are subjected to 240,000 cycles of dynamic load aging prior to the fracture resistance test. The fracture resistance is measured in Newton (N). The Failure mode patterns are analyzed and categorized using a scanning electron microscope (SEM). The results are analyzed using a two-way ANOVA with Bonferroni's Post-Hoc test, followed by a one-way ANOVA for each factor. That is in addition to one-way ANOVA for surface treatment under each thickness, each followed by Bonferroni's Post-Hoc test. Then, a T-test is used to compare the two thicknesses under each surface treatment. All tests are set at 0.05 significance level. RESULTS The two-way ANOVA test revealed that restoration thickness and surface treatment both significantly affect the fracture resistance values (p<0.05). The highest fracture resistance mean (2672±216N) is obtained from HF at 1.0 mm thickness, while the lowest mean (2104±299N) is obtained from APF at 0.5 mm thickness. CONCLUSION All test groups, regardless of thickness, demonstrated fracture resistance values that exceeded both normal and parafunctional bite forces. The veneers that bonded after hydrofluoric acid etching followed by ceramic primer application showed more favourable fracture patterns.
Collapse
Affiliation(s)
- Maged Zahran
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Shaimaa Abo El-Farag
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Hassan Soltan
- Production and Mechanical Design Engineering Department, Faculty of Engineering, Mansoura University, Mansoura 35516, Egypt.
| | - Ahmed Attia
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| |
Collapse
|
13
|
Haralur SB, Alqahtani AM, Shiban AS, Alattaf ZM, Chaturvedi S, AlQahtani SM, Alqahtani NM. Influence of different surface treatment on bonding of metal and ceramic Orthodontic Brackets to CAD-CAM all ceramic materials. BMC Oral Health 2023; 23:564. [PMID: 37574557 PMCID: PMC10423419 DOI: 10.1186/s12903-023-03246-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Accepted: 07/21/2023] [Indexed: 08/15/2023] Open
Abstract
BACKGROUND Developing efficient bonding techniques for orthodontic brackets and all-ceramic materials continues to pose a clinical difficulty. This study aimed to evaluate the shear bond strengths (SBS) of metal and ceramic brackets to various all-ceramic CAD-CAM materials, such as lithium disilicate CAD (LDS-CAD), polymer-infiltrated ceramic (PIC), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia after different surface treatments and thermal cycling. MATERIALS AND METHODS The samples were divided into two groups to be bonded with ceramic and metal lower incisor brackets. Each group was subdivided into a control group devoid of any surface treatment, 10% HF acid (HFA) etching, ceramic etch & prime (MEP), Al2O3 air abrasion, and medium grit diamond bur roughening. After surface treatment, brackets were bonded with composite resin cement, thermal cycled, and tested for shear bond strength. The failed surfaces were evaluated with a digital microscope to analyse the type of failure. The data were statistically analysed using a one-way ANOVA and Tukey HSD tests at p < 0.05. RESULTS The highest mean bond strengths were found with HFA etching in LDS-CAD (13.17 ± 0.26 MPa) and ZLS (12.85 0.52 MPa). Diamond bur recorded the lowest mean bond strength roughening across all the ceramic groups. There were significant differences in mean shear bond values per surface treatment (p < 0.001) and ceramic materials. CONCLUSION Among the surface treatment protocols evaluated, HFA etching and MEP surface treatment resulted in enhanced bond strength of both ceramic and metal brackets to CAD-CAM all ceramic materials.
Collapse
Affiliation(s)
- Satheesh B Haralur
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, 62529, Saudi Arabia.
| | | | - Abdullah Saeed Shiban
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, 62529, Saudi Arabia
| | | | - Saurabh Chaturvedi
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, 62529, Saudi Arabia
| | - Saeed M AlQahtani
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, 62529, Saudi Arabia
| | - Nasser M Alqahtani
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, 62529, Saudi Arabia
| |
Collapse
|
14
|
Jassim SJ, Majeed MA. Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study). Heliyon 2023; 9:e17790. [PMID: 37449108 PMCID: PMC10336531 DOI: 10.1016/j.heliyon.2023.e17790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 06/09/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023] Open
Abstract
Objectives This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods Sixty cylindrical specimens (5 mm diameter × 3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was treated with a plasma device (PiezoBrush® PZ3 Handheld Device, Relyon Plasma, Regensburg, Germany). G-Multi PRIMER was applied, then self-adhesive cement (G-CEM ONE) was applied using a split mold (1 mm diameter × 3 mm height), and μSBS was tested in a universal testing machine. The surface roughness was measured using a profilometer. Nine additional specimens of each material for wettability test using an optical tensiometer. Statistical analysis The data were analyzed using ANOVA and Bonferroni test at a level of significance of 0.05. Results The highest mean of μSBS was recorded by AII (27.3 MPa), while the lowest was recorded by AI (17.9 MPa). One-way ANOVA test revealed a significant difference among groups. Bonferroni test showed each two subgroups significant difference except subgroups AI, CI and BII, CII, where there was a non-significant difference. For all CAD/CAM materials, conventional treatment increased the surface roughness compared to plasma treatment, while the contact angle decreased after plasma treatment. Conclusion Plasma treatment increased the μSBS of resin cement to zirconia significantly while not significantly affecting the μSBS of resin nano-ceramic. Conventional treatment of lithium disilicate provided significantly higher μSBS than plasma treatment.
Collapse
|
15
|
Vohra F, Alsaif R, Alsayed H, AlSaeed MM, Mourad AME. Decontamination of lithium disilicate ceramics using various photosensitizers, herbal and chemical disinfectants, and the effect of surface conditioners on bond strength values. Photodiagnosis Photodyn Ther 2023:103619. [PMID: 37209762 DOI: 10.1016/j.pdpdt.2023.103619] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/11/2023] [Accepted: 05/15/2023] [Indexed: 05/22/2023]
Abstract
AIM To assess and compare the antimicrobial efficacy of disinfectants on lithium disilicate ceramic (LDC) used in dental applications and shear bond strength (SBS) of LDC after using different conditioners hydrofluoric acid (HF), self-etching ceramic primers (SECP) and Neodymium-doped yttrium orthovanadate (Nd: YVO4). MATERIALS AND METHODS One hundred and twenty LDC discs were fabricated by auto-polymerizing acrylic resin using the lost wax technique. S. aureus, S. mutans, and C. albican were inoculated on thirty discs (n=30 each). Each group was further divided into three subgroups based on different disinfecting agents used (n=30) Group 1: Garlic extract, Group 2: Rose Bengal (RB) activated by PDT, and Group 3: Sodium hypochlorite (NaOCl). An assessment of the survival rate of microorganisms was performed. The remaining thirty samples were surface treated using three different LDC surface conditioners (n=10) Group 1: HF + Silane (S), group 2: SECP, and Group 3: Nd: YVO4 laser+S. SBS and failure mode analysis were performed using a universal testing machine and stereomicroscope at 40x magnification, The statistical analysis was conducted using one-way ANOVA and Post Hoc Tukey test. RESULTS Garlic extract, RB, and 2% NaOCl sample displayed comparable outcomes of antimicrobial potency against C. albicans, S aureus, and S. mutans (p>0.05). Furthermore, SBS analysis showed HF+S, SECP, and Nd: YVO4+S exhibited comparable outcomes of bond strength (p>0.05). CONCLUSION Garlic extract and Rose bengal activated by PDT can be contemplated as alternatives to the chemical agent NaOCl used for LDC disinfection. Similarly, SECP and Nd: YVO4 possess the potential to be used for the surface conditioning of LDC to improve the bond integrity with resin cement.
Collapse
Affiliation(s)
- Fahim Vohra
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Rawan Alsaif
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Hussain Alsayed
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Mojahid M AlSaeed
- University Dental Hospital King Saud University P.O Box 60169, Riyadh 11545, Saudi Arabia.
| | | |
Collapse
|
16
|
Essam N, Soltan H, Attia A. Influence of thickness and surface conditioning on fracture resistance of occlusal veneer. BMC Oral Health 2023; 23:258. [PMID: 37138255 PMCID: PMC10157962 DOI: 10.1186/s12903-023-02932-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 04/03/2023] [Indexed: 05/05/2023] Open
Abstract
BACKGROUND The purpose of the current study was to assess the impact of restoration thickness, surface conditioning and the interaction between them on the fracture resistance of CAD/CAM fabricated lithium disilicate occlusal veneers. METHODS A total of 42 maxillary molars were prepared to receive CAD/CAM fabricated lithium disilicate occlusal veneer either with 0.5 mm (n = 21) or 1 mm (n = 21) thickness. Each main group was divided into 3 subgroups (n = 7), according to surface treatment, HF acid (HF-1, HF-0.5), acidulated phosphate fluoride (APF-1, APF-0.5) and Monobond etch & prime (MON-1, MON-0.5). Multilinik N (Ivoclar-Vivadent) adhesive resin cement was used for bonding according to the manufacturer instructions. One hour after bonding, specimens were stored in water bath for 75 days followed by cyclic loading fatigue for 240,000 cycles to simulate clinical situation. Finally, specimens were fractured under compressive load in (N) using a universal testing machine. Two and one-way ANOVA and Post Hoc Tukey test were used for statistical analysis. RESULTS The means ± SD (N) fracture load for each group were calculated. MON-1 group showed the highest fracture load (1644.7 ± 155.3) followed by HF-1 group (1514.6 ± 212.5). Meanwhile, APF-0.5 showed the lowest fracture load (962 ± 249.6). CONCLUSION CAD/CAM fabricated lithium disilicate occlusal veneers can be used with a thickness of 0.5 mm instead of conventional crowns. Monobond etch & prime is recommended as a surface treatment for CAD/CAM fabricated lithium disilicate occlusal veneer due to biological hazards of Hydrofluoric acid.
Collapse
Affiliation(s)
- Noha Essam
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura university, El Gomhouria St, Mansoura, Dakahlia Governorate, Egypt
| | - Hassan Soltan
- Faculty of Engineering, Mansoura university, Dakahlia Governorate, Egypt
| | - Ahmed Attia
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura university, El Gomhouria St, Mansoura, Dakahlia Governorate, Egypt.
| |
Collapse
|
17
|
Fuchs F, Westerhove SM, Schmohl L, Koenig A, Suharbiansah RSR, Hahnel S, Rauch A. Influence of the Application Time of Silane for the Bonding Performance between Feldspar or Lithium Disilicate Ceramics and Luting Resin Composites. J Funct Biomater 2023; 14:jfb14040231. [PMID: 37103321 PMCID: PMC10143910 DOI: 10.3390/jfb14040231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/11/2023] [Accepted: 04/14/2023] [Indexed: 04/28/2023] Open
Abstract
A correct silanization time is essential for successful surface functionalization and sufficient bonding to dental ceramics. The shear bond strength (SBS) of lithium disilicate (LDS) and feldspar (FSC) ceramics and luting resin composite was investigated with respect to different silanization times, taking into account the physical properties of the individual surfaces. The SBS test was performed with a universal testing machine, and the fracture surfaces were evaluated by stereomicroscopy. The surface roughness of the prepared specimens was analyzed after etching. Changes in surface properties due to surface functionalization were evaluated by surface free energy (SFE) via contact angle measurement. Fourier transform infrared spectroscopy (FTIR) was used to determine the chemical binding. The roughness and SBS of the control group (no silane, etched) were higher for FSC than for LDS. Regarding the SFE, the dispersive fraction increased and the polar fraction decreased after silanization. FTIR confirmed the presence of silane on the surfaces. The SBS of LDS showed a significant increase from 5 to 15 s, depending on the silane and luting resin composite. For FSC, cohesive failure was observed for all samples. For LDS specimens, a silane application time of 15 to 60 s is recommended. Based on clinical conditions, no difference between the silanization times was observed for FSC specimens, indicating that etching alone produces sufficient bonding.
Collapse
Affiliation(s)
- Florian Fuchs
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
| | - Sina Maria Westerhove
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
| | - Leonie Schmohl
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
| | - Andreas Koenig
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
| | | | - Sebastian Hahnel
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
- Department of Dental Prosthetics, UKR University Hospital Regensburg, 93053 Regensburg, Germany
| | - Angelika Rauch
- Department of Prosthetic Dentistry and Material Science, Leipzig University, 04109 Leipzig, Germany
- Department of Dental Prosthetics, UKR University Hospital Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
18
|
Utar M, Demirtağ Z. Four-point flexural strength and microtensile bond strength of digitally and conventionally veneered zirconia. Eur J Oral Sci 2023; 131:e12926. [PMID: 36792368 DOI: 10.1111/eos.12926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 01/27/2023] [Indexed: 02/17/2023]
Abstract
This study intended to evaluate the effect of digital veneering on four-point flexural strength (FS) and microtensile bond strength (μTBS) of veneered zirconia. Two different zirconia blocks, a lithium disilicate and a feldspathic ceramic block, and two different layering ceramics were used. IPS e.max Zir CAD (ZC) and Vita In-Ceram YZ (YZ) with yttria stabilized tetragonal zirconia polycrystals (3Y-TZP) were used as substructures. IPS e.max CAD (LD), Vita Mark II (VMII), IPS e.max Ceram (EC) and Vita VM9 (VM9) were used for veneering. Resin cement and fusion ceramic were placed between veneer and zirconia substructure for digital veneering. A total of one hundred and fifty specimens in five groups (n = 30) were prepared for FS and tested in universal machine at 1.0 mm/min. One hundred specimens in five groups (n = 20) were obtained for the μTBS and tested at 1.0 mm/min. Statistical analysis was made by one way ANOVA and Tukey HSD. Conventional veneering showed statistically significant FS. ZC veneered with EC had the highest mean FS and the lowest was obtained in groups veneered through resin cement. YZ layered with VM9 had the highest mean μTBS. ZC veneered through fusion ceramic and YZ veneered through resin cement showed significantly lower and similar μTBS.
Collapse
Affiliation(s)
- M Utar
- Kırıkkale University, Kırıkkale, Turkey
| | | |
Collapse
|
19
|
Alayed A. Influence of Lithium disilicate pretreatment using photodynamic therapy, non-thermal plasma, and laser treatment on surface roughness and bond strength. Photodiagnosis Photodyn Ther 2023; 42:103512. [PMID: 36935048 DOI: 10.1016/j.pdpdt.2023.103512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 02/26/2023] [Accepted: 03/08/2023] [Indexed: 03/19/2023]
Abstract
AIMS To assess the shear bond strength (SBS) and surface roughness (Ra) of lithium disilicate ceramic (LDC) after using different pretreatment methods i.e., Non-Thermal Plasma (NTP), self-etching ceramic primer (SECP), curcumin photosensitizer (CP), Er and Cr: YSGG lasers (ECL) in comparison to hydrofluoric acid + Silane (HF + S) MATERIALS AND METHODS: : A total of fifty LDC discs were prepared. All the discs were arbitrarily divided into five groups based on the surface conditioning used (n=10). Group 1: PDT+S, group 2: HF+ S, group 3: NTP + S, group 4: SECP, and group 5: ECL+ S. A confocal optical microscope was used to calculate Ra for each sample. A self-adhesive resin cement was applied followed by LED light curing. A universal testing machine was used to assess SBS and a stereomicroscope was used to determine the failure mode. Two-way analysis of variance (ANOVA), and a Tukey post hoc test was used to analyze data (p=0.05) RESULTS: : The highest bond integrity of resin luting bonded to conditioned LDS ceramics were presented by group 2 (HF+ S) (21.48±1.39 MPa) and lowest by group 1 (CP+S) (13.01±1.19 MPa) respectively. Intergroup comparison analysis revealed that group 1(13.01±1.19 MPa) and group 3 (14.28±0.62 MPa) displayed comparable outcomes of bond integrity(p>0.05). Similarly, it was observed that group 2 (21.48±1.39 MPa) and group 5 (21.31±1.85MPa) exhibited comparable values of bond strength(p>0.05). Specimens conditioned with HF+ S showed the highest Ra (1445.86±0.019µm). However, discs treated with SECP exhibited the lowest Ra (0139.76±0.081µm) CONCLUSION: Er, Cr: YSGG laser retains the ability to be used as an LDC surface conditioner as an alternative to HF+ S.Both the methods of pretreatment results in high surface roughness of LDC.
Collapse
Affiliation(s)
- Abdullah Alayed
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| |
Collapse
|
20
|
Dapieve KS, Velho HC, da Rosa LS, Pivetta JP, Maidana FC, Venturini AB, Kleverlaan CJ, Pereira GKR, Valandro LF. Ceramic surface conditioning, resin cement viscosity, and aging relationships affect the load-bearing capacity under fatigue of bonded glass-ceramics. J Mech Behav Biomed Mater 2023; 139:105667. [PMID: 36657192 DOI: 10.1016/j.jmbbm.2023.105667] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/09/2023]
Abstract
This study aimed to evaluate the influence of ceramic surface treatments, resin cement viscosities, and storage regimens on the fatigue performance of bonded glass-ceramics (lithium disilicate, LD; feldspathic, FEL). Ceramic discs (Ø = 10 mm; thickness = 1.5 mm) were allocated into eight groups per ceramic (n = 15), considering three factors: "ceramic surface treatment" in two levels - 5% hydrofluoric acid etching and silane-based coupling agent application (HF), or self-etching ceramic primer (E&P); "resin cement viscosity" in two levels - in high or low viscosity; and "storage regimen" in two levels - baseline, 24 h to 5 days; or aging, 180 days + 25,000 thermal cycles. Adhesive luting was performed onto glass fiber-reinforced epoxy resin discs (Ø = 10 mm; thickness = 2 mm) and the bonded assemblies were subjected to cyclic fatigue tests: initial load = 200 N; step-size = 25 N (FEL) and 50 N (LD); 10,000 cycles/step; 20 Hz. Scanning electron microscopy (SEM) inspections were performed. Regarding the LD ceramic, the fatigue behavior was reduced after aging for HF_HIGH and E&P_LOW conditions, while stable performance was observed for HF_LOW and E&P_HIGH. Regarding the FEL results, aging negatively affected HF_HIGH, E&P_HIGH, and E&P_LOW, being that only the HF_LOW condition presented a stable behavior. The failure initiated from defects on the etched surface of the ceramics, where the cross-sectional analysis commonly revealed unfilled areas. Long-term aging might induce a decrease in mechanical behavior. The 'ceramic microstructure/surface conditioning/resin cement viscosity relationships' modulate the fatigue performance of lithium disilicate and feldspathic glass-ceramics.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Helder Callegaro Velho
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Jordana Pavanelo Pivetta
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Cocco Maidana
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andressa Borin Venturini
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North-Holland, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
21
|
Lambert H, Corn S, Léger R, Ienny P, Slangen P, Fages M. Ceramic Bonding Interface under Shear-Compression Stress: Ultra-High-Speed Imaging Contribution. J Dent Res 2023; 102:295-301. [PMID: 36562502 DOI: 10.1177/00220345221138500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
The aim of this study is to visualize and characterize by ultra-high-speed imaging (UHSI) the failure phenomena at the resin-ceramic bonding interface of lithium disilicate (LiSi2) samples bonded with gold-standard protocol (Monobond Plus [MB]) and the nontoxic one (Monobond Etch & Prime [MEP]) subjected to mechanical loading. Unprecedented frame rate, image resolution, and recording time were reached by using the most advanced UHSI camera. The finite element analysis (FEA) of the proposed mechanical test confirmed that the specific design of our samples enables a combined shear and compression stress state, prone to test the bonding interface while being close to physiological stresses. Ten LiSi2 samples were pretreated by gold standard (MB, n = 5) and self-etching primer (MEP, n = 5). Axial compression loading gradually increased until catastrophic failure was performed. As shown by the FEA, the angle between the bonding interface and load direction leads to shear-compression stresses at the resin-ceramic bonding interface. Failure was recorded by UHSI at 300,000 fps. All recorded images were analyzed to segregate events and isolate the origin of fracture. For the first time, thanks to the image recording setup, it was observed that debonding is the first event before breakage, highlighting that sample fracture occurs by interfacial rupture followed by slippage and cohesive failure of materials. Failure mode could be described as mixed. MEP and MB showed similar results and behavior.
Collapse
Affiliation(s)
- H Lambert
- Laboratory Bioengineering and Nanosciences, University of Montpellier, Montpellier, France.,Department of Prosthetic Dentistry, Faculty of Odontology, Montpellier University, France
| | - S Corn
- LMGC, Univ Montpellier, IMT Mines Ales, CNRS, Ales, France
| | - R Léger
- LMGC, Univ Montpellier, IMT Mines Ales, CNRS, Ales, France
| | - P Ienny
- LMGC, Univ Montpellier, IMT Mines Ales, CNRS, Ales, France
| | - P Slangen
- EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, Ales, France
| | - M Fages
- Laboratory Bioengineering and Nanosciences, University of Montpellier, Montpellier, France.,Department of Prosthetic Dentistry, Faculty of Odontology, Montpellier University, France
| |
Collapse
|
22
|
The Effect of Surface Treatments on Zirconia Bond Strength and Durability. J Funct Biomater 2023; 14:jfb14020089. [PMID: 36826888 PMCID: PMC9968119 DOI: 10.3390/jfb14020089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 02/10/2023] Open
Abstract
To evaluate the effects of airborne particle abrasion (APA) combined with MDP-containing resin cement, a glass-ceramic spray deposition (GCSD) method on the shear bond strengths (SBSs) and durability of 3 mol% yttrium oxide-stabilized zirconia ceramic (3Y-TZP) compared with lithium disilicate glass ceramics (LDGC). 3Y-TZP disks were randomly treated as follows: for Group APA+MDP, 3Y-TZP was abrased using 50 μm Al2O3 particles under 0.1 Mpa and bonded with MDP-containing resin cement; for Group GCSD, 3Y-TZP was treated with the GCSD method, etched by 5% HF for 90 s, silanized and bonded with resin cement without MDP. Group LDGC was bonded as the Group GCSD. X-ray diffraction (XRD), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and energy dispersive X-ray detector (EDX) were used to analyze the surface chemical and micro-morphological changes of the ceramics before bonding. The bonded ceramic specimens were randomly divided into subgroups, and the SBSs were determined before and after 10,000 thermocycling. The SBSs were analyzed with a one-way ANOVA analysis. Failure modes were determined with optical microscopy and SEM. The XRD, ATR-FTIR and XPS results identified the formation of lithium disilicate and zirconium silicate on 3Y-TZP after GCSD. The SEM micrographs revealed that 3Y-TZP surfaces were roughened by APA, while 3Y-TZP with GCSD and LDGC surfaces could be etched by HF to be porous. The APA treatment combined with MDP-containing resin cement produced the high immediate zirconia shear bond strengths (SBSs: 37.41 ± 13.51 Mpa) that was similar to the SBSs of the LDGC (34.87 ± 11.02 Mpa, p > 0.05), but, after thermocycling, the former dramatically decreased (24.00 ± 6.86 Mpa, maximum reduction by 35.85%) and the latter exhibited the highest SBSs (30.72 ± 7.97 Mpa, minimum reduction by 11.9%). The 3Y-TZP with GCSD treatment displayed the lower zirconia SBSs before thermocycling (27.03 ± 9.76 Mpa, p < 0.05), but it was similar to the 3Y-TZP treated with APA and MDP containing resin cement after thermocycling (21.84 ± 7.03 vs. 24.00 ± 6.86 Mpa, p > 0.05). The APA combined with MDP-containing resin cement could achieve the high immediate zirconia SBSs of those of the LDGC, but it decreased significantly after thermocycling. The GCSD technique could yield the immediate zirconia SBSs similar to those of LDGC before thermocycling, and long-term zirconia SBSs were similar to those of 3Y-TZP treated with APA followed by MDP-containing resin cement after thermocycling. Hence, the GCSD technique could enrich zirconia surface treatments and is an alternative to zirconia surface pretreatment for 3Y-TZP bond durability.
Collapse
|
23
|
Effects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD-CAM Blocks under Aging Protocols. BIOMED RESEARCH INTERNATIONAL 2023. [DOI: 10.1155/2023/7982813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one-component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium-infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD-CAM material blocks with a thickness of 2 mm made of lithium disilicate glass-ceramic (IPS e.max CAD) and zirconium-infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N-Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD-CAM blocks, and two different aging procedures (
). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long-term (TL) and short-term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov-Smirnov/Shapiro-Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (
). The TS-TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was
, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.
Collapse
|
24
|
Ma KSK, Wang LT, Blatz MB. Efficacy of adhesive strategies for restorative dentistry: A systematic review and network meta-analysis of double-blind randomized controlled trials over 12 months of follow-up. J Prosthodont Res 2023; 67:35-44. [PMID: 35691823 DOI: 10.2186/jpr.jpr_d_21_00279] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
PURPOSE The efficacy of etch-and-rinse, selective enamel-etching, and self-etching protocols for universal adhesives in follow-ups of over 12 months was compared in a network meta-analysis. STUDY SELECTION Randomized controlled trials (RCTs) published from 1998 to 2022 that compared marginal staining, marginal adaptation, retention and fractures, post-operative sensitivity, or recurrence of caries that took place over 12-months post-restoration were selected. A network meta-analysis determined the performance of each adhesive protocol. RESULTS After screening 981 articles, 16 RCTs were subjected to data extraction. Of which, 674 patients with 2816 restorations, were included in the network meta-analysis. The pooled risk of marginal discoloration following self-etching was significantly higher than that following etch-and-rinse at over 12, 24, and 36 months, which was time-dependent. The pooled risks of unfavorable marginal adaptation and unfavorable retention and fractures following self-etching were also significantly higher than that following etch-and-rinse, with the rates of unfavorable retention and fractures in non-carious cervical lesions increasing in a time-dependent manner. The pooled risks of marginal discoloration, unfavorable marginal adaptation, retention and fractures were similar between etch-and-rinse and selective enamel-etching protocols. Post-operative hypersensitivity and recurrence of caries were not significantly different among etch-and-rinse, selective enamel-etching, and self-etching protocols. CONCLUSIONS In follow-ups over 12 months, esthetic and functional outcomes of restorations completed with an etch-and-rinse adhesive protocol were superior to the ones achieved with a self-etching strategy without selective enamel-etching. Selective enamel etching is recommended for self-etching systems. Biological responses were similar for all three adhesive strategies.
Collapse
Affiliation(s)
- Kevin Sheng-Kai Ma
- Center for Global Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA.,Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, MA.,Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Li-Tzu Wang
- National Taiwan University (NTU) Hospital and College of Medicine, NTU, Taipei, Taiwan
| | - Markus B Blatz
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
25
|
Avram LT, Galațanu SV, Opriș C, Pop C, Jivănescu A. Effect of Different Etching Times with Hydrofluoric Acid on the Bond Strength of CAD/CAM Ceramic Material. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7071. [PMID: 36295139 PMCID: PMC9605186 DOI: 10.3390/ma15207071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 09/28/2022] [Accepted: 09/30/2022] [Indexed: 06/16/2023]
Abstract
The objective of this study was to evaluate the influence of hydrofluoric acid (HF) and conditioning time on the micro-shear bond strength (µSBS) between dual-cure resin cement and glass-ceramic materials, such as lithium disilicate ceramic (IPS e.max CAD, Ivoclar Vivadent) (EX) and leucite-reinforced ceramic (IPS Empress CAD, Ivoclar Vivadent) (EP), and also a hybrid ceramic (Vita Enamic, Vita Zahnfabrik) (VE). Eighteen sections with 1 mm thickness were cut from each CAD/CAM material and randomly divided into three groups, according to the surface etching time (30 s, 60 s, 90 s). The surface treatment was performed using 9.5% HF acid gel, then resin cement was applied on the prepared ceramic plates and light cured. µSBS values between resin cement and the ceramic material were measured with a universal testing machine at a crosshead speed of 0.5 mm/min until the failure occurred. The fractured surfaces of specimens were microscopically evaluated, and failure modes were classified as: adhesive between resin cement and ceramic, cohesive within ceramic or cement and mixed failure. Surface roughness of etched samples was examined using a scanning electron microscope. Obtained data were statistically analysed using one-way analysis of variance (ANOVA) and Bonferroni post hoc test with a level of significance α = 0.05. The results of the statistical methods applied indicate that µSBS mean difference for leucite-reinforced ceramic (EP) was statistically significant (p < 0.05). However, µSBS values for hybrid ceramic (VE) and lithium disilicate ceramic (EX) were not affected, from a statistical point of view, by the conditioning time (p > 0.05).
Collapse
Affiliation(s)
- Liane Tabitha Avram
- Department of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy “Victor Babeș” Timișoara, Revoluţiei din 1989 Bd. No. 9, 300070 Timișoara, Romania
| | - Sergiu-Valentin Galațanu
- Department of Mechanics and Strength of Materials, Politehnica University of Timisoara, Mihai Viteazu Bd., 300222 Timisoara, Romania
| | - Carmen Opriș
- Department of Materials and Manufacturing Engineering, Politehnica University of Timisoara, Mihai Viteazu Bd., Timis, 300222 Timisoara, Romania
| | - Cristian Pop
- Department of Mechatronics, Politehnica University of Timisoara, Mihai Viteazu Bd., 300222 Timisoara, Romania
| | - Anca Jivănescu
- Department of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy “Victor Babeș” Timișoara, Revoluţiei din 1989 Bd. No. 9, 300070 Timișoara, Romania
- TADERP Research Center, University of Medicine and Pharmacy “Victor Babeș” Timișoara, Revoluţiei din 1989 Bd. No. 9, 300070 Timișoara, Romania
| |
Collapse
|
26
|
Grangeiro MTV, Rodrigues CDS, Rossi NR, da Silva JMD, Ramos NDC, Tribst JPM, Anami LC, Bottino MA. Effect of Surface-Etching Treatment, Glaze, and the Antagonist on Roughness of a Hybrid Ceramic after Two-Body Wear. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15196870. [PMID: 36234211 PMCID: PMC9573409 DOI: 10.3390/ma15196870] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 07/26/2022] [Accepted: 08/01/2022] [Indexed: 06/12/2023]
Abstract
Stains and glaze are effective procedures for achieving an aesthetic smoothness on indirect restorations. Thus, the effect of surface-etching treatments previous to the stain layer and the glaze application on the occlusal and antagonist wear of a hybrid ceramic were evaluated against different antagonists. Disc-shaped samples were prepared from polymer-infiltrated ceramic network (PICN) blocks. The specimens were divided into eight groups, according to the surface-etching treatment and glaze application: P (polished specimens); PG (polishing plus glaze); E (hydrofluoric acid etching plus stain); EG (acid etching plus stain plus glaze); A (aluminum oxide sandblasting plus stain); AG (sandblasting plus stain plus glaze); S (self-etching primer plus stain); SG (self-etching primer plus stain plus glaze). Half of the samples were subjected to a wear simulation with a steatite antagonist, and the other half was tested using a PICN antagonist. The test parameters were: 15 N, 1.7 Hz, 6 mm of horizontal sliding, 5000 cycles. The discs and the antagonists' masses were measured before and after the wear tests. The average roughness and spacing defects were evaluated. The etching treatment affected the surface and antagonist mass loss when tested against steatite. AG showed the highest mass loss. This influence was not detected when using the PICN antagonist. The glaze application after staining ensures a smoother surface and avoids antagonist wear.
Collapse
|
27
|
Velho HC, da Rosa LS, Temp RW, Cocco FM, Pereira GKR, May LG, Valandro LF. Adhesive application after ceramic surface treatment is detrimental to load-bearing capacity under fatigue of a lithium disilicate glass-ceramic. J Mech Behav Biomed Mater 2022; 135:105453. [PMID: 36126505 DOI: 10.1016/j.jmbbm.2022.105453] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/30/2022] [Accepted: 09/03/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate whether an adhesive application after surface treatment on a lithium disilicate ceramic (LD) has an influence on its load-bearing capacity under fatigue. METHODS LD discs (Ø= 10 mm; thickness= 1 mm) were allocated into 8 groups (n= 15), considering 3 factors: "ceramic surface treatment" - HF: hydrofluoric acid + universal primer application; or MEP: single-component ceramic primer; "adhesive application" - with or without; and "aging protocol" - baseline: 24 h to 7 days; or aging: 180 days of storage + 25,000 thermal cycles. The LD discs were adhesively bonded to glass fiber-reinforced epoxy resin discs (Ø= 10 mm; thickness= 2 mm) and stored according to the condition and each group. Cyclic fatigue testing (initial load= 100 N; step size= 100 N until600 N and after step size= 25 N to failure; 10,000 cycles/step; 20 Hz frequency) was performed. Fractographic and adhesive interface analyzes were also performed. The collected data were then analyzed by Kaplan Meier and Mantel-Cox tests and One-way ANOVA. RESULTS The adhesive application in the baseline condition had no influence on the load-bearing capacity under fatigue when the HF surface treatment was performed, however, adhesive application for the MEP treatment led to worse results than without it. The adhesive application in the aged condition showed worse fatigue outcomes for both treatments. All specimens presented radial cracks. MEP treatment followed by adhesive application presented the thickest luting layer. CONCLUSION The adhesive application after surface treatments of a lithium disilicate glass-ceramic is detrimental to its load-bearing capacity under fatigue when adhesively luted onto a supporting substrate.
Collapse
Affiliation(s)
- Helder Callegaro Velho
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renatta Wrasse Temp
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Maidana Cocco
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Liliana Gressler May
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
28
|
Hilgemberg B, de Siqueira FSF, Cardenas AFM, Ribeiro JL, Dávila-Sánchez A, Sauro S, Loguercio AD, Arrais CAG. Effect of Bonding Protocols on the Performance of Luting Agents Applied to CAD-CAM Composites. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6004. [PMID: 36079385 PMCID: PMC9457303 DOI: 10.3390/ma15176004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/17/2022] [Accepted: 08/19/2022] [Indexed: 06/15/2023]
Abstract
This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (μSBS) of luting agents to CAD−CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD−CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers’ recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the μSBS test. Data were analyzed using two-way ANOVA and Bonferroni’s post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The μSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest μSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in μSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD−CAM composite but also to resin cement/bonding agent/silane used.
Collapse
Affiliation(s)
- Bruna Hilgemberg
- Department of Restorative Dentistry, State University of Ponta Grossa (UEPG), Ponta Grossa 840030-900, Brazil
| | | | | | - Josiane Loch Ribeiro
- Department of Restorative Dentistry, State University of Ponta Grossa (UEPG), Ponta Grossa 840030-900, Brazil
| | - Andrés Dávila-Sánchez
- Departmento de Odontología Restauradora y Materiales Dentales, Escuela de Odontología, Universidad San Francisco de Quito USFQ, Pampite y Diego de Robles, Quito 170901, Ecuador
| | - Salvatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Departmento de Odontologia, Facultad de Ciencias de la Salud Universidad, CEU-Cardenal Herrera, Alfara del Patriarca, 46115 Valencia, Spain
- Department of Therapeutic Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia
| | | | - Cesar Augusto Galvao Arrais
- Department of Restorative Dentistry, State University of Ponta Grossa (UEPG), Ponta Grossa 840030-900, Brazil
| |
Collapse
|
29
|
Okutan Y, Kandemir B, Donmez MB, Yucel MT. Effect of the thickness of CAD-CAM materials on the shear bond strength of light-polymerized resin cement. Eur J Oral Sci 2022; 130:e12892. [PMID: 35969188 DOI: 10.1111/eos.12892] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/19/2022] [Indexed: 11/29/2022]
Abstract
This study aimed to investigate the effect of the thickness of computer aided design-computer aided manufacturing (CAD-CAM) restorative materials on the bond strength of light-polymerized resin cement. Ninety specimens were prepared from three different CAD-CAM materials (a leucite-based glass-ceramic [Empress CAD], a polymer-infiltrated ceramic network [Vita Enamic], and a zirconia-reinforced lithium silicate glass-ceramic [Vita Suprinity]) in different thicknesses (1, 2, and 3 mm). One surface of each specimen was treated by using a single-step self-etching ceramic primer (Monobond Etch & Prime). Light-polymerized resin cement was bonded to treated surfaces by exposure to a light-emitting diode curing unit from the untreated side of the samples. Shear bond strength (SBS) between the ceramic and the resin cement was measured by using a universal testing machine. The leucite-based glass-ceramic had higher SBS values than the other materials at each thickness. For each material, 1 mm-thick specimens had the highest SBS values. The difference between the SBS values of 2 mm- and 3 mm-thick polymer-infiltrated ceramic network was nonsignificant, whereas the SBS values of 2 mm-thick leucite-based glass-ceramic and the zirconia-reinforced lithium silicate glass-ceramic were significantly higher than those of the corresponding 3 mm-thick specimens. The choice of the material and its thickness may be highly important for clinical success when light-polymerized resin cements are used for cementation.
Collapse
Affiliation(s)
- Yener Okutan
- Department of Prosthodontics, Faculty of Dentistry, Aydin Adnan Menderes University, Aydin, Turkey
| | - Banucicek Kandemir
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Munir Tolga Yucel
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| |
Collapse
|
30
|
Wahjuningrum DA, Norberto CRJ, Fernanda MML, Sari AA, Pawar AM, Cruz González AC. Micro-shear bond strength of different surface treatments on a polymer infiltrated ceramic network. F1000Res 2022; 11:798. [PMID: 37997604 PMCID: PMC10665602 DOI: 10.12688/f1000research.122108.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/11/2022] [Indexed: 11/25/2023] Open
Abstract
Background: Polymer infiltrated ceramic networks, or hybrid ceramics, are a combination of infiltrating polymerizable organic monomers into a pre-sintered porous ceramic matrix. In addition to having good mechanical properties, the polymer infiltrated ceramic network must comply with the possibility of adequate bonding to the resinous cement. The surface conditioning of this hybrid material must be carefully considered due to its organic composition and ceramic network. The purpose of this research is to evaluate the effect of hydrofluoric acid and a self-etching ceramic primer, under two different application times, on the bond strength of a polymer infiltrated ceramic network. Methods: Blocks of a polymer infiltrated ceramic network were cut to obtain sheets, and these were randomized into five groups. For the group termed AAS, airborne-particle abrasion with Al 2O 3 (aluminum oxide) of 50µm was used. For groups HF2 and HF6, hydrofluoric acid was used for 20 and 60 seconds respectively, and for the groups MB2 and MB6, a self-etch ceramic primer was applied for 20 and 60 seconds respectively. A silane was applied to the groups AAS, HF2, and HF6 after the treatment. After 24-hour storage in distilled water, a micro-shear bond strength test was performed using a universal mechanical testing machine. All samples were evaluated in a stereomicroscope at 40x and 50x to determine the type of failure. Results: The highest and lowest values of bond strength were reported by groups MB6 and AAS, respectively. Groups HF2, HF6, MB6, and MB2 did not report statistically significant differences. The predominant failure pattern was a mixed failure. Conclusions: With the limitations of the present investigation, the treatments of self-etching ceramic primer and hydrofluoric acid followed by silane were reported to be statistically equal at 20 and 60 seconds.
Collapse
Affiliation(s)
- Dian Agustin Wahjuningrum
- Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia
| | | | | | - Amanda Andika Sari
- Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia
| | - Ajinkya M. Pawar
- Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai 400008, Maharashtra, India
| | | |
Collapse
|
31
|
Pinto RDAS, Castro FM, Moura DMD, de Miranda LM, Miranda JS, de Carvalho RLA, Souza RODAE, Leite FPP. Effect of different surface treatments on the micro tensile bond strength to dentin, biaxial flexural strength and roughness of CAD/CAM resin composite and polymer infiltrated ceramic. J Mech Behav Biomed Mater 2022; 131:105257. [DOI: 10.1016/j.jmbbm.2022.105257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/21/2022] [Accepted: 04/25/2022] [Indexed: 11/27/2022]
|
32
|
de Brito OFF, Sandes JM, de Lima FCG, Oliveira JB, Alves LC, Brayner FA, de Melo Monteiro GQ. The Influence of Cement Removal Techniques on In Situ Bacterial Adhesion and Biodegradation at the Marginal Interface of Ceramic Laminates. Oper Dent 2022; 47:190-201. [DOI: 10.2341/20-269-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/02/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives
This in situ study aimed to analyze the influence of different resin cement removal techniques on bacterial adhesion and biodegradation at the marginal interface of ceramic laminates.
Methods and Materials
Eighty feldspathic ceramic (F) blocks were prepared and cemented onto bovine enamel slabs (7×2.5×2 mm). Excess cement was removed using a microbrush (MBR), a scalpel blade (SCP), or a Teflon spatula (TSP). For the biodegradation analysis, 40 disc-shaped resin cement specimens were prepared (7×1.5 mm) using a Teflon mold. The specimens were randomly allocated into two groups: (1) No finishing procedure (only Mylar strip), and (2) with finishing and polishing procedures using the Jiffy system (Ultradent, South Jordan, UT, USA) (n=20). The in situ phase consisted of using an intraoral palatal device by 20 volunteers for 7 days. Each device contained five cylindrical wells (8×3 mm), where three dental blocks and two cement specimens were included in the wells. Surface roughness (Ra) was measured using a contact profilometer. A micromorphological analysis was performed under a stereomicroscope and a scanning electron microscope. Bacterial adhesion was quantitated based on the number of colony-forming units (CFU/mL) and their biofilm development potential.
Results
The cement removal techniques directly affected surface roughness at the marginal interface (p<0.001), and the SCP technique produced higher mean roughness, regardless of the surface area analyzed. Surface polishing protected cement specimens from further biodegradation (p=0.148). There were no differences in CFU counts between the groups after the in situ phase (p=0.96). All specimens showed CFU with a strong ability to develop a biofilm.
Conclusions
The techniques used for cement removal increased the surface roughness of ceramic laminates, particularly SCP, but they did not affect bacterial adhesion at the marginal interface. Surface polishing of the resin cement is recommended to mitigate biodegradation.
Collapse
Affiliation(s)
- OFF de Brito
- *Oscar Felipe Fonseca de Brito, DDS, MSc, PhD, Dental School, University of Pernambuco, FOP/UPE, Brazil
| | - JM Sandes
- Jana Messias Sandes, BSc, MSc, PhD, Electronic Microscopy, Laboratory of Immunopathology Keizo Asami, Federal University of Pernambuco, Brazil
| | - FCG de Lima
- Fernanda Cristina Gomes de Lima, BSc, MSc, PhD, Laboratory of Molecular and Cellular Biology, Department of Parasitology, Institute Aggeu Magalhães – Fiocruz, Pernambuco, Brazil
| | - JB Oliveira
- Jorge Belém Oliveira Júnior, BSc, MSc, Laboratory of Molecular and Cellular Biology, Department of Parasitology, Institute Aggeu Magalhães - Fiocruz, Pernambuco, Brazil
| | - LC Alves
- Luiz Carlos Alves, Biol, MSc, PhD, Electronic Microscopy, Laboratory of Immunopathology Keizo Asami, Federal University of Pernambuco and Laboratory of Molecular and Cellular Biology, Department of Parasitology, Institute Aggeu Magalhães - Fiocruz, Pernambuco, Brazil
| | - FA Brayner
- Fábio André Brayner, Biol, MSc, PhD, Electronic Microscopy, Laboratory of Immunopathology Keizo Asami, Federal University of Pernambuco and Laboratory of Molecular and Cellular Biology, Department of Parasitology, Institute Aggeu Magalhães - Fiocruz, Pernambuco, Brazil
| | - GQ de Melo Monteiro
- Gabriela Queiroz de Melo Monteiro, DDS, MSc, PhD, Dental School, University of Pernambuco, FOP/UPE, Brazil
| |
Collapse
|
33
|
Martins JD, Moura DMD, Lima CM, de Carvalho RLA, Leite FPP, Souza ROA. Surface Treatment and Cementation of Lithium Silicate Ceramics Containing ZrO2. Oper Dent 2022; 47:202-213. [DOI: 10.2341/20-156-l] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective
To evaluate the effect of different surface treatments on the shear bond strength (SBS) of lithium silicate (LS) and lithium disilicate (LD) ceramics, after thermocycling.
Methods and Materials
For SBS test, 72 ceramic blocks (18×14×2 mm) were made (24 blocks from each ceramic material): VITA Suprinity (LSS), Celtra Duo (LSC), and Lithium disilicate (LD). The blocks were polished with sandpaper of increasing grit (#280, #400, #800, and #1200) and embedded in chemically activated acrylic resin. Afterwards, they were randomly divided into 12 groups (6 blocks per group) according to: “Ceramic” (LD, LSC, and LSS) and “Surface treatment” (HFS: hydrofluoric acid + silane; MEP: Monobond Etch & Prime/Ivoclar). From each treated surface ceramic block, four dual-curing resin cement cylinders (RelyX U200, 3M Oral Care) were prepared using a Tygon tube (Ø=3 mm and h=2 mm) and light cured for 40 seconds (1000 mW/cm2) (N=288/n=24). All specimens were submitted to thermocycling (10,000 cycles, 5°C and 55°C, 30 seconds) and then to SBS test at a crosshead speed of 1 mm/min using a 50-kgf load cell. Forty-five additional blocks were made for roughness and SEM analysis. Failure mode was also performed. The data (MPa) were statistically analyzed by oneway analysis of variance (ANOVA), Tukey test (5%), and Weibull analysis. The Ra was analyzed by Kruskal–Wallis and Dunn Test (5%). The other variables were analyzed qualitatively.
Results
ANOVA revealed that “surface treatment” was significant for all ceramic materials (p<0.05). The LD-HFS (18.66±3.49), LSC-HFS (16.81±2.62), and LSS-HFS (16.33±3.08) groups had significantly higher SBS than the LD-MEP (7.00±4.2), LSC-MEP (14.12±3.51), and LSS-MEP (13.87±2.52) groups. Complete adhesive failures at the cement– dentin interface were more frequent. Weibull modulus was superior for the LD-HFS (6.22), LSC-HFS (8.8), and LSS-HFS (7.4) groups.
Conclusion
HF followed by silanization is the most suitable surface treatment for the cementation of LS and LD glass ceramics.
Collapse
Affiliation(s)
- JD Martins
- Jordana Dias Martins, DDS, MSc, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - DMD Moura
- Dayanne Monielle Duarte Moura, DDS, MSc, PhD, professor, Department of Dentistry, State University of Rio Grande do Norte (UERN), Caicó/RN, Brazil
| | - CM Lima
- Camila Moreira Lima, DDS, MSc, PhD student, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - RLA de Carvalho
- Ronaldo Luís Almeida de Carvalho, MSc, PhD, professor, Department of Dentistry, School of Dentistry, Centro Universitário Braz Cubas, Mogi das Cruzes, Brazil
| | - FPP Leite
- Fabíola Pessôa Pereira Leite, DDS, MSc, PhD, professor Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - ROA Souza
- *Rodrigo Othávio Assunção e Souza, DDS, MSc, PhD, adjunct professor, Health Science Center, Department of Dentistry, School of Dentistry, Federal University of Rio Grande do Norte (UFRN), Lagoa Nova, Natal, Brazil
| |
Collapse
|
34
|
Almiro M, Marinho B, Delgado AHS, Rua J, Monteiro P, Santos IC, Proença L, Mendes JJ, Gresnigt MMM. Increasing Acid Concentration, Time and Using a Two-Part Silane Potentiates Bond Strength of Lithium Disilicate-Reinforced Glass Ceramic to Resin Composite: An Exploratory Laboratory Study. MATERIALS 2022; 15:ma15062045. [PMID: 35329495 PMCID: PMC8950098 DOI: 10.3390/ma15062045] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 02/21/2022] [Accepted: 03/04/2022] [Indexed: 02/04/2023]
Abstract
There is still a lack of consensus concerning the recommended etching concentration, application time and type of silane when bonding lithium disilicate-reinforced glass ceramics manufactured by CAD/CAM. The purpose of this study was thus to conduct an in vitro study which investigates the influence of hydrofluoric acid (HF) concentration, etching time and silane type on the microtensile bond strength (μTBS) of lithium disilicate to resin composites. Thirty-nine IPS e.max CAD blocks were randomly divided between thirteen groups (n = 3). The variables were HF concentration (9.5 or 4.9%), etching time (20 or 60 s) and silane type (Bis-Silane, Monobond Plus and ESPE Sil Silane). The blocks were cut into beams, aged for 10,000 cycles in a thermocycler and submitted to tensile stress to determine μTBS. A control group featuring the Monobond Etch & Prime (MEP) agent that combines etching/silanisation into a simultaneous process was also added. This group was discarded from the analysis due to only having pre-test failures. The data were analysed using a three-way ANOVA (α = 0.05). The HF concentration, etching time and silane type significantly influenced μTBS (p < 0.001). Significant interactions between time and silane type (p = 0.004), HF concentration and silane type (p < 0.001) and among the three factors (p < 0.001) were noted. Etching lithium disilicate with 9.5% HF (60 s), followed by the application of Bis-Silane, resulted in the highest μTBS (16.6 ± 9.0 MPa). The highest concentration and etching time under study, combined with a two-part silane, resulted in the highest bond strength, while the application of MEP showed a complete pre-test failure.
Collapse
Affiliation(s)
- Matilde Almiro
- Department of Conservative Dentistry, Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (M.A.); (B.M.)
| | - Beatriz Marinho
- Department of Conservative Dentistry, Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (M.A.); (B.M.)
| | - António H. S. Delgado
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
- Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London (UCL), London NW3 2PF, UK
| | - João Rua
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Paulo Monteiro
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Inês Caetano Santos
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Luís Proença
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - José João Mendes
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Marco M. M. Gresnigt
- University Medical Center Groningen, Department of Restorative Dentistry and Biomaterials, Center for Dentistry and Oral Hygiene, University of Groningen, 9713 AV Groningen, The Netherlands
- Department of Special Dental Care, Martini Hospital, 9728 NT Groningen, The Netherlands
- Faculty of Health Sciences, University Arthuro Prat, Iquique 2120, Chile
- Correspondence:
| |
Collapse
|
35
|
Lührs A, Brachmann C, Jacker‐Guhr S. Dentin contamination during repair procedures: A threat to universal adhesives? Clin Exp Dent Res 2022. [PMCID: PMC9209802 DOI: 10.1002/cre2.551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Objective This study examined the influence of surface contamination during repair procedures with hydrofluoric acid, silane, or ammonium polyfluoride on the bond strength of universal adhesives to dentin using different etching modes before and after thermocycling. Materials and Methods Dentin surfaces of human molars were contaminated in different ways (silane, hydrofluoric acid, ammonium polyfluoride, and no pretreatment as control) followed by application of a universal adhesive (etch & rinse or self‐etch mode). After a composite build‐up was placed onto each tooth, sticks for the microtensile bond strength (MTBS) test were sectioned. Half of the sticks were tested after water storage for 24 h, the other half after thermocycling (15,000 cycles, 5/55°C). The MTBS data were analyzed statistically by using the Kolmogorov–Smirnov test, one‐way analysis of variance, and Tukey HSD test (p < 0.05). The fracture patterns of all specimens were evaluated and analyzed using a χ2 test. Results Dentin contamination with a multifunctional silane does not influence microtensile bond strength irrespective of aging. Contamination with hydrofluoric acid or an ammonium polyfluoride primer leads to a significantly lower bond strength after aging, irrespective of the etch mode. Conclusion Dentin contamination with hydrofluoric acid or ammonium polyfluorides during repair procedures should be avoided, as they appear to decrease the bond strength of universal adhesives.
Collapse
Affiliation(s)
- Anne‐Katrin Lührs
- Department of Conservative Dentistry, Periodontology and Preventive Dentistry Hannover Medical School Hannover Germany
| | - Cosima Brachmann
- Department of Prosthetic Dentistry and Biomedical Materials Research Hannover Medical School Hannover Germany
| | - Silke Jacker‐Guhr
- Department of Conservative Dentistry, Periodontology and Preventive Dentistry Hannover Medical School Hannover Germany
| |
Collapse
|
36
|
Zhang LX, Hong DW, Zheng M, Yu H. Is the bond strength of zirconia-reinforced lithium silicate lower than that of lithium disilicate? A systematic review and metaanalysis. J Prosthodont Res 2021; 66:530-537. [PMID: 34853237 DOI: 10.2186/jpr.jpr_d_20_00112] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study systematically reviewed the literature to compare the bond strength of resin composites with that of zirconia-reinforced lithium silicate (ZLS) and lithium disilicate (LD). STUDY SELECTION This review was structured based on the Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA 2020) statement. This study was registered at the International Prospective Register of Systematic Reviews (CRD42021256900). Studies were searched via PubMed, Web of Science, and Google Scholar databases without language or publication year limits. In vitro studies that evaluated the bond strength of the resin composites to ZLS and LD were included. The risk of bias in all the included articles was evaluated. Statistical analyses were performed using the Review Manager software (version 5.3, Cochrane Collaboration, Oxford, UK). RESULTS Of the 90 potentially related articles, the full texts of 16 articles were evaluated after screening. Finally, sevenstudies were included in the qualitative synthesis and meta-analysis. All the studies presented a medium risk of bias. The results showed no significant difference in bond strength between the ZLS and LD groups (P = 0.94, mean difference=0.08, and 95% confidence interval=-1.93 to 2.10). However, a significant difference was found in the subgroup analysis considering different types of aging treatments (P = 0.0008) and different types of bond strength tests (P < 0.00001). CONCLUSION The bond strength of resin composites was found to be similar to that of ZLS and LD, but different aging treatments and bond strength tests exhibited varying effects on the bond strength.
Collapse
Affiliation(s)
- Li-Xian Zhang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Deng-Wei Hong
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Ming Zheng
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China.,Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
| |
Collapse
|
37
|
Orthodontic bonding to silicate ceramics: impact of different pretreatment methods on shear bond strength between ceramic restorations and ceramic brackets. Clin Oral Investig 2021; 26:2827-2837. [PMID: 34792666 PMCID: PMC8898251 DOI: 10.1007/s00784-021-04260-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 10/23/2021] [Indexed: 12/04/2022]
Abstract
Objective The study aims to investigate the shear bond strength (SBS) between silicate ceramic restorations and ceramic brackets after different pretreatments and aging methods. Material and methods Leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with (i) 4% hydrofluoric acid + silane (HF), (ii) Monobond Etch&Prime (MEP), (iii) silicatization + silane (CoJet), and (iv) SiC grinder + silane (SiC). Molars etched (phosphoric acid) and conditioned acted as comparison group. SBS was measured after 24 h (distilled water, 37 °C), 500 × thermocycling (5/55 °C), and 90 days (distilled water, 37 °C). Data was analyzed using Shapiro–Wilk, Kruskal–Wallis with Dunn’s post hoc test and Bonferroni correction, Mann–Whitney U, and Chi2 test (p < 0.05). The adhesive remnant index (ARI) was determined. Results LEU pretreated with MEP showed lower SBS than pretreated with HF, CoJet, or SiC. LiSi pretreated with MEP resulted in lower initial SBS than pretreated with HF or SiC. After thermocycling, pretreatment using MEP led to lower SBS than with CoJet. Within LiSi group, after 90 days, the pretreatment using SiC resulted in lowest SBS values. After HF and MEP pretreatment, LEU showed lower initial SBS than LiSi. After 90 days of water storage, within specimens pretreated using CoJet or SiC showed LEU higher SBS than LiSi. Enamel presented higher or comparable SBS values to LEU and LiSi. With exception of MEP pretreatment, ARI 3 was predominantly observed, regardless the substrate, pretreatment, and aging level. Conclusions MEP pretreatment presented the lowest SBS values, regardless the silicate ceramic and aging level. Further research is necessary. Clinical relevance There is no need for intraoral application of HF for orthodontic treatment.
Collapse
|
38
|
Comparison between Hydrofluoric Acid and Single-Component Primer as Conditioners on Resin Cement Adhesion to Lithium Silicate and Lithium Disilicate Glass Ceramics. MATERIALS 2021; 14:ma14226776. [PMID: 34832176 PMCID: PMC8621437 DOI: 10.3390/ma14226776] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 10/25/2021] [Accepted: 10/30/2021] [Indexed: 11/17/2022]
Abstract
This study aimed at evaluating the effects of different surface conditionings on the microshear bond strength (µSBS) of a self-adhesive resin cement to VITA Suprinity (ZLS) and IPS e.max CAD (LD). Three surface conditioning protocols were performed on ZLS and LD before luting with a self-adhesive resin cement (RelyX Unicem 2, RXU): hydrofluoric acid (HF), HF + silane (HF + S), or Monobond Etch & Prime (EP). In each group, 15 cylindrical buildups of RXU were prepared on five milled bars and submitted to a µSBS test. Data were statistically analyzed with two-way ANOVA and Tukey’s post hoc test (p < 0.05). Failure modes were recorded and classified as adhesive, mixed, cohesive in resin, or ceramic, and statistically analyzed with Fisher’s exact test (p = 0.05). One additional bar per group was used for the morphological characterization of the conditioned surface by means of SEM. The material per se did not significantly influence adhesion (p = 0.744). Conditioning protocol was a significant factor: EP yielded significantly higher μSBS than HF (p = 0.005), while no significant differences emerged between EP and HF + S (p = 0.107), or HF + S and HF (p = 0.387). The material-conditioning protocol interaction was not statistically significant (p = 0.109). Significant intergroup differences were found in distribution of failure modes: mixed failures were predominant in the ZLS/EP group, while the other groups showed a prevalence of adhesive failures. The self-etching primer showed promising results in terms of immediate bond strength of a self-adhesive resin cement to lithium-silica-based glass ceramics, suggesting its alternative use to hydrofluoric acid and silane conditioning protocols.
Collapse
|
39
|
Repair Bond Strength of Composite Resin to Aged Resin and Glass-Matrix CAD/CAM Ceramic Materials Using Two Different Repair Systems. COATINGS 2021. [DOI: 10.3390/coatings11111331] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study evaluates the repair bond strength of resin-matrix and glass-matrix CAD/CAM ceramic materials based on two repair systems. Thirty specimens measuring 2.5 mm in thickness were prepared from Crystal Ultra (CU), Vita Enamic (EN), Lava Ultimate (LU), Cerasmart (CS), and Vitablocs Mark II (VM2) materials and aged for 5000 thermal cycles. Specimens were randomly allocated into three groups: control, Monobond-S (MS) primer, and Monobond Etch & Prime (MEP). Composite resin (Tetric N Ceram) (5 mm in diameter and 2 mm thick) was packed and light-cured onto treated specimen surfaces. Subsequently, the specimens’ shear bond strength (SBS) was evaluated, and failure modes was recorded. Statistical analysis was performed using factorial ANOVA and Tukey’s post hoc tests (a = 0.05). The factorial ANOVA revealed significant interactions between the material type and repair system, which was significant (p < 0.01). The highest and lowest SBS were obtained for CU (27.09 ± 1.11) and VM2 (4.30 ± 0.59) in MS and control groups, respectively. In all the groups, CU demonstrated higher SBS, whereas VM2 demonstrated lower SBS. There were no significant differences in SBS between EN and LU, and CS and CU in all the study groups (p > 0.05). The Monobond-S repair system provided non-significantly higher SBS compared to the MEP systems, except for VM2 and LU materials. The new resin-matrix CAD/CAM material demonstrated the highest SBS compared to the other materials for both conventional and MEP repair systems. Both repair systems showed clinically acceptable bond strength and allowed for successful repair of the resin-matrix ceramic materials.
Collapse
|
40
|
Nagasawa Y, Eda Y, Shigeta H, Ferrari M, Nakajima H, Hibino Y. Effect of sandblasting and/or priming treatment on the shear bond strength of self-adhesive resin cement to CAD/CAM blocks. Odontology 2021; 110:70-80. [PMID: 34272634 DOI: 10.1007/s10266-021-00635-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 06/24/2021] [Indexed: 11/30/2022]
Abstract
The aim of this study was to investigate the effect of two different priming agents and/or sandblasting on the shear bond strength of self-adhesive resin cement to the resin composite for core build-up to CAD/CAM blocks. A CAD/CAM ceramic block (GN I CERAMIC BLOCK, GC) and a CAD/CAM resin composite block (CERASMART 270, GC), a self-adhesive resin cement (G-CEM ONE, GC) and two different primers, i.e., a multipurpose primer (MP; G-Multi Primer, GC) and a ceramic primer (CP; Ceramic Primer II, GC), were examined. Five different surface treatments with priming and/or sandblasting and no surface treatment (control) were performed on the block. Disk specimens (6 mm in diameter and 4 mm in thickness) made from core composites were cemented to the blocks after the surface treatments. Then, the 24-h shear bond strength of the resin cement between the block and the resin composite core was determined (n = 15). Sandblasted specimens had greater bond strength than controls for both blocks (p < 0.05). Priming to both blocks significantly increased the bond strength of resin cement compared to that of controls (p < 0.05). Although Weibull moduli were not significantly changed among all surface treatments for both blocks, the strengths with 5% and 95% failure probability of sandblasted and/or primed blocks were estimated to be greater than those of controls. The combination of priming and sandblasting to the CAD/CAM composite and ceramic surface was effective in increasing the bond strength of the resin cement.
Collapse
Affiliation(s)
- Yuko Nagasawa
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan.
| | - Yoshikazu Eda
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Hirotaka Shigeta
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Marco Ferrari
- Department of Prosthodontics and Dental Materials, School of Dental Medicine, University of Siena, Viale Mario Bracci, 16, Siena, Italy
| | - Hiroshi Nakajima
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Yasushi Hibino
- Division of Dental Biomaterials Science, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1, Keyakidai, Sakado, Saitama, 350-0283, Japan
| |
Collapse
|
41
|
Dalla-Nora F, Guilardi LF, Zucuni CP, Valandro LF, Rippe MP. Fatigue Behavior of Monolithic Zirconia-Reinforced Lithium Silicate Ceramic Restorations: Effects of Conditionings of the Intaglio Surface and the Resin Cements. Oper Dent 2021; 46:316-326. [PMID: 34251409 DOI: 10.2341/20-025-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/12/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study assessed the effect of conditioning of the intaglio surface and resin cements on the fatigue behavior of zirconia-reinforced lithium silicate ceramic (ZLS) restorations cemented to a dentin analogue. METHODS ZLS ceramic (Ø=10 mm, thickness=1.5 mm) and dentin analogue (Ø=10 mm, thickness=2.0 mm) discs were produced and allocated according to the study factors, totaling nine study groups: ceramic surface treatment (three levels: hydrofluoric acid etching [HF]; self-etching ceramic primer [EP]; tribochemical silica coating [TBS]) and resin cement (three levels: 10-methacryloyloxydecyl dihydrogen phosphate [nMDP]; MDP-containing conventional resin cement [MDP]; self-adhesive resin cement [SA]). The ceramic bonding surfaces were treated and cemented on the dentin analogue, and all the specimens were aged for 5000 thermal cycles (5°C-55°C) prior to fatigue testing. The stepwise fatigue test (20 Hz frequency) started with a load of 400 N (5000 cycles) followed by steps of 500, 600, and up to 1800 N (step-size: 100 N) at a maximum of 10,000 cycles each step. The specimens were loaded until failure (crack), which was detected by light transillumination and visual inspection at the end of each step. The fatigue failure load and number of cycles for failure data were analyzed by the Kaplan-Meier (log-rank test; α=0.05). Topographic and fractographic analyses were also performed. RESULTS HF- (973.33-1206.67 N) and EP- (866.67-1066.67 N) treated specimens failed at statistically similar loads and higher than TBS (546.67-733.33 N), regardless of the cement used. All the fractographical inspections demonstrated failure as radial crack. CONCLUSION The HF and EP treatments promoted better mechanical fatigue behavior of the ceramic restoration, while tribochemical silica coating induced worse fatigue results and should be avoided for treating the ZLS surface prior to bonding.
Collapse
|
42
|
Nascimento AR, Mantovani MB, Mendonça LC, Vesselovcz J, Pacheco RR, Pini NP, Sundfeld D. Two-Year Follow-Up of Self-Etching Ceramic Primer as Surface Treatment for Feldspathic Veneers: A Clinical Case Review. Oper Dent 2021; 46:126-135. [PMID: 34192329 DOI: 10.2341/20-036-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2020] [Indexed: 11/23/2022]
Abstract
The two-step approach of applying hydrofluoric acid followed by silane is deemed the goldstandard surface treatment protocol before bonding to glass ceramics. Given hydrofluoric acid is a toxic conditioning agent and with the intention to simplify this step, the dental company Ivoclar Vivadent (Schaan, Lietchtenstein) released a self-etching ceramic primer, Monobond Etch & Prime in 2015, claiming that hydrofluoric acid and silane application would no longer be required prior to luting glass ceramics. Therefore, this clinical case report and retrospective analysis describes the replacement of unsatisfactory anterior veneers due to clinical failures for new feldspathic glass ceramic veneers, using the aforementioned self-etching ceramic primer. After two years, feldspathic glass ceramics presented satisfying clinical performance with absence of debonding, tooth sensitivity, recurrent carious lesions, or marginal infiltration.
Collapse
|
43
|
Azevedo VLB, de Castro EF, Bonvent JJ, de Andrade OS, Nascimento FD, Giannini M, Cavalli V. Surface treatments on CAD/CAM glass-ceramics: Influence on roughness, topography, and bond strength. J ESTHET RESTOR DENT 2021; 33:739-749. [PMID: 33991436 DOI: 10.1111/jerd.12734] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 03/23/2021] [Accepted: 04/04/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the influence of surface treatment on roughness (SA), topography, and shear bond strength (SBS) of computer-aided designer and manufacture (CAD/CAM) zirconia-reinforced lithium silicate (ZLS) and feldspathic (FEL) glass-ceramics. MATERIALS AND METHODS FEL and ZLS specimens were submitted to 5% or 10% hydrofluoric acid (HF) or self-etching ceramic primer (MEP) and different application times (20, 40, and 60 s), or to sandblasting (Control, 20 s). Resin cement cylinders were bonded to the specimens and tested in shear (n = 10) after 24 h and 16-months of water storage. SA and topography were evaluated by atomic force (AFM, n = 10) and scanning electron microscopy. Data were analyzed by ANOVA and Bonferroni test (α = 0.05). RESULTS Sandblasting promoted the highest SA for ZLS, but 10% HF (40, 60 s) promoted higher SBS at 16 months. 10% HF produced the highest SA for FEL, but sandblasting and 5% HF (20 s) maintained SBS after 16 months, without differences from 10% HF (20 s) (p > 0.05). Overall, MEP produced lower SA and SBS among groups (p < 0.05). HF displayed greater morphological changes on FEL. CONCLUSION 10% HF (40 s) provided better results for ZLS, while 5% or 10% HF (20 s) was suitable for FEL. CLINICAL SIGNIFICANCE Surface treatments influenced SA, topography, and SBS of materials. HF etching is the surface treatment of choice for both CAD/CAM glass-ceramics.
Collapse
Affiliation(s)
| | - Eduardo Fernandes de Castro
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| | - Jean-Jacques Bonvent
- Department of Center for Natural and Human Sciences, Federal University of ABC, Santo André, Brazil
| | | | | | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| | - Vanessa Cavalli
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| |
Collapse
|
44
|
Ueda N, Takagaki T, Nikaido T, Takahashi R, Ikeda M, Tagami J. The effect of different ceramic surface treatments on the repair bond strength of resin composite to lithium disilicate ceramic. Dent Mater J 2021; 40:1073-1079. [PMID: 33883329 DOI: 10.4012/dmj.2020-362] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to evaluate the bonding abilities and long-term durability of different repair agents when applied to lithium disilicate ceramics (LDS). Blocks of IPS e.max CAD were prepared and divided into four groups according to the surface treatment: Monobond Etch & Prime (ME), K-etchant GEL+Clearfil Universal Bond (UB), Bondmer Lightless (BL), and K-etchant GEL+G-Multi Primer (GMP). All treated ceramic specimens were bonded to resin composite and light-cured. The micro-shear bond strength was measured after 24 h of water storage or 5,000 thermocycles. ME and BL showed significantly higher initial bond strengths than UB and GMP (p<0.05). After 5,000 thermocycles, there was no significant difference in ME (p>0.05), but BL and GMP showed considerable reduction in bond strength (p<0.05); moreover, the samples of UB were all de-bonded before testing. ME and BL proved to be effective surface treatment materials for LDS.
Collapse
Affiliation(s)
- Nanako Ueda
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Toru Nikaido
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Rena Takahashi
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masaomi Ikeda
- Department of Oral prosthetic Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
45
|
Abouelleil H, Colon P, Jeannin C, Goujat A, Attik N, Laforest L, Gauthier R, Grosgogeat B. Impact of the Microstructure of CAD/CAM Blocks on the Bonding Strength and the Bonded Interface. J Prosthodont 2021; 31:72-78. [PMID: 33835621 DOI: 10.1111/jopr.13361] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/31/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To investigate the relationship between the microstructure of CAD/CAM blocks and the quality of adhesion as function of the surface treatment and resin cement type. MATERIALS AND METHODS Two nano-ceramic composite resin CAD/CAM blocks, Lava Ultimate (LU) and Cerasmart (CS), and two Leucite-reinforced glass ceramic CAD/CAM IPS blocks, Empress® CAD (EM) and InitialTM LRF (IR), received either Hydrofluoric acid (HF) or sandblasting (SB) surface treatments. The blocks were then luted using two dual-cure resin cements, LinkForce (LF) and Multilink Automix (ML) with their corresponding silanes, resulting in 16 study groups. The luted blocks were then thermal-cycling (TC) for 5000 cycles and subjected to a microtensile bond strength (μTBS) test. Scanning electron microscopy (SEM) micrographs of the treated surfaces were analyzed using ImageJ software and XRD analyses were performed for the two ceramic blocks. The data obtained were submitted to Games-Howell post-hoc nonparametric test to compare combinations of groups or treatments and a linear mixed-effects model for the factors surface treatment, block type, and resin cement, together with their first-degree interactions (α = 0.05). RESULTS The lowest mean μTBS values were obtained with LU-HF, whereas the highest mean μTBS values were obtained with CS regardless of resin cement type and surface treatment method. IR-HF mean μTBS were significantly higher than IR-SB, EM-SB, and EM-HF. Analysis using ImageJ software demonstrated significant differences in the density and pore size after HF surface treatment. CONCLUSIONS The specific microstructure of each block material within the same family group impacted the micromechanical retention and the bonded interface strength.
Collapse
Affiliation(s)
- Hazem Abouelleil
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France
| | - Pierre Colon
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Département d'Odontologie Conservatrice - Endodontie. Université de Paris, Faculté dentaire, Hôpital Rothschild, Assistance Publique-Hôpitaux de Paris, France
| | - Christophe Jeannin
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| | - Alexis Goujat
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| | - Nina Attik
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France
| | - Laurent Laforest
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France
| | - Remy Gauthier
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France
| | - Brigitte Grosgogeat
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| |
Collapse
|
46
|
Tribst JPM, Maria de Oliveira Dal Piva A, Werner A, Sampaio Silva LT, Anami LC, Bottino MA, Kleverlaan CJ. Effect of surface treatment and glaze application on shade characterized resin-modified ceramic after toothbrushing. J Prosthet Dent 2021; 125:691.e1-691.e7. [PMID: 33820617 DOI: 10.1016/j.prosdent.2020.12.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 12/13/2020] [Accepted: 12/14/2020] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM The extrinsic characterization with pigments and glaze application on the surface of ceramic restorations promotes individualization and esthetics. However, whether this characterization is resistant to toothbrushing abrasive wear is unclear. PURPOSE The purpose of this in vitro study was to investigate the abrasive wear resistance of characterized and glazed resin-modified ceramic with different surface treatments before characterization. MATERIAL AND METHODS Eighty rectangular specimens (10×8×6 mm) were precision cut from Vita Enamic and randomly divided in 4 groups as per the surface treatment before the characterization technique. These groups included the following: no additional treatment or polishing only, acid etching, airborne-particle abrasion, and self-etching silanization. For each surface treatment, 2 subgroups were created considering the presence or absence of the glaze layer after shade characterization, totaling 8 groups (n=10). The specimens were submitted to toothbrushing simulation (150 000 cycles, 2.45-N, 180 strokes per minute) with a soft and straight toothbrush and a solution of toothpaste and distilled water (250 g/L). After each 50 000 cycles, the wear of the characterized surface was measured by using a contact profilometer in μm which was equivalent to 5, 10, and 15 years of simulated toothbrushing. The rates were analyzed by using 3-way ANOVA and the post hoc Tukey test (α=.05). Scanning electron microscopy analysis was performed to access the surface profile between the evaluated periods. RESULTS The mean wear rate (Rz) of the characterized surface was affected by the isolated factors, including surface treatment, glaze, and time (P<.001), with no interactive effects noted. A higher mean value of Rz was observed for polishing only (12.9 ±4.4 μm), followed by airborne-particle abrasion (10.2 ±4.5 μm), acid etching (9.4 ±2.4 μm), and then self-etching silanization (7.6 ±2.9 μm). Mean wear rate was also increased by the glaze (11.1 ±4.7 μm) compared with its absence (9 ±3.2 μm) and by the length of time, with 15 years (11.3 ±4.5 μm) followed by 10 years (9.8 ±4.0 μm) and 5 years (9 ±3.6 μm). The scanning electron microscopy images showed similar worn surfaces for each subgroup, glaze removal after 150 000 cycles, and surface homogeneity in function of time. CONCLUSIONS Self-etching silanization was found to be the treatment suitable for reducing the wear of characterized resin-modified ceramic during prolonged brushing of more than 5 years. Glaze application did not protect the characterization from surface wear, regardless of the ceramic surface treatment performed on the specimens.
Collapse
Affiliation(s)
| | - Amanda Maria de Oliveira Dal Piva
- PhD, Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| | - Arie Werner
- Engineer, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | | | - Lilian Costa Anami
- Professor, Department of Dentistry, Santo Amaro University (UNISA), São Paulo, Brazil
| | - Marco Antonio Bottino
- Professor, Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| | - Cornelis Johannes Kleverlaan
- Professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| |
Collapse
|
47
|
Baeshen HA. Influence of photodynamic therapy and different conventional methods on conditioning of lithium di silicate ceramics bonded to metallic brackets: An assessment of bond strength. Photodiagnosis Photodyn Ther 2021; 34:102210. [PMID: 33592331 DOI: 10.1016/j.pdpdt.2021.102210] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 01/21/2021] [Accepted: 02/05/2021] [Indexed: 01/08/2023]
Abstract
AIM The aim of the current study was to assess the effect of different conditioning methods on Lithium di silicate (LDC) employing conventional and contemporary regimes bonded to metallic brackets. MATERIAL AND METHODS 70 discs of LDC were prepared and polished to attain smooth surface. Samples were allocated into seven groups according to ceramic surface conditioning. Group 1 surface treated with Er-YAG laser and saline (S), Group 2 PDT using MBP + S, Group 3 H F + S (control), Group 3 HF (Hydrofluoric acid) + saline, Group 4 HF (Hydrofluoric acid) + ultrasonic bath (UB) + S, Group 5 sand blasting the glass ceramic surface with 120 um Al2O3, Group 6 LDC surface conditioned with SECP(Etch and Prime) and Group 7 ECL(Laser) + S on was irradiated on LDC. Both chemical and mechanical surface treatments of LDC were followed by placement of metallic brackets. Samples were arranged in universal testing machine for shear bond strength (SBS) testing. Bond failure of brackets were assessed using ARI. To assess and compare the mean and standard deviations (SD) among experimental groups analysis of variance (ANOVA) was employed. All treatment combination means were compared using the post hoc Tukey's multiple comparison test at a significance level of (p ≤ 0.05). RESULTS SBS values of Group 2 H F acid + S displayed highest bond durability (22.28 ± 1.09 MPa). Whereas, specimens in Group 4 surface treated with 120 μm Al2O3 displayed lowest SBS scores (11.81 ± 0.55 MPa) and these bond scores were comparable to PDT using MBP + S (12.54 ± 1.09 MPa) (p > 0.05). LDC surface treated by ECL + S (21.11 ± 3.85 MPa), HF + UB + S (19.28 ± 0.52 MPa) exhibited results comparable to HF acid + S (p > 0.05). CONCLUSION LDC conditioned with HFS still remains as gold standard. Use of PDT for surface treatment of LDC and bonded to metallic bracket is not recommended as it results in decreased bond durability. Use of ECL-S and HF + UB + S has a potential to be used alternatively to HFS for LDC conditioning.
Collapse
Affiliation(s)
- Hosam A Baeshen
- Orthodontic Department, Faculty of Dentistry, King Abdulaziz University. P.O. Box 80209, Jeddah, 21589, Saudi Arabia.
| |
Collapse
|
48
|
Recen D, Yildirim B, Othman E, Comlekoglu E, Aras I. Bond strength of metal brackets to feldspathic ceramic treated with different surface conditioning methods: an in vitro study. Eur Oral Res 2021; 55:1-7. [PMID: 33937755 PMCID: PMC8055263 DOI: 10.26650/eor.20210004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Purpose: To compare MEP which is originally manufactured for increasing bond strength between organic resins and ceramic with conventional surface treatment methods in preparation of leucite-reinforced FC surfaces regarding shear bond strength (SBS) of stainless steel brackets and the mode of bond failure. Materials and methods: Forty specimens that were fabricated from FC material and glazed were randomly assigned to four surface conditioning methods: (1) CoJet Sand; (2) MEP; (3) HF acid etching followed by silane coupling agent; (4) Diamond bur followed by silane coupling agent. The SBS was determined using universal testing machine. Bond failure sites were classified according to Adhesive Remnant Index (ARI). Results: No statistically significant difference (p less than 0.05) was found in SBS between the groups while significant intergroup differences were detected concerning ARI scores (p less than 0.001). Group 1 had ARI score 1 and 2 indicating mode of failure at the adhesive interface with greater percentage of the adhesive left on bracket base. The other groups had higher frequency of ARI score 3 and 2. The quantity of the ARI retained on the ceramic surface was highest in Group 3, followed by Group 4 and Group 2. Conclusion: MEP can be a suitable alternative for bonding metal brackets to FC surface.
Collapse
Affiliation(s)
- Duygu Recen
- Izmir Democracy University, Faculty of Dentistry,Department of Restorative Dentistry, Izmir,Turkey
| | - Bengisu Yildirim
- Usak University, Faculty of Dentistry, Department of Prosthodontics, Usak,Turkey
| | - Eman Othman
- Jacksonville University, Brooks Rehabilitation College of Healthcare Sciences, School of Orthodontics,Jacksonville, FL,USA
| | - Erhan Comlekoglu
- Ege University, Faculty of Dentistry, Department of Prosthodontics, İzmir,Turkey
| | - Isil Aras
- Jacksonville University, Brooks Rehabilitation College of Healthcare Sciences, School of Orthodontics,Jacksonville, FL,USA
| |
Collapse
|
49
|
Nogueira IDO, Oliveira PFGD, Magno MB, Ferreira DMTP, Maia LC, Rabello TB. Does the application of an adhesive layer improve the bond strength of etched and silanized glass-ceramics to resin-based materials? A systematic review and meta-analysis. J Prosthet Dent 2021; 125:56-64. [DOI: 10.1016/j.prosdent.2019.12.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 12/06/2019] [Accepted: 12/09/2019] [Indexed: 11/17/2022]
|
50
|
Lima CM, Silva NRD, Martins JD, Miranda JS, Tanaka R, Souza RODAE, Leite FPP. Effect of different surface treatments on the biaxial flexure strength, Weibull characteristics, roughness, and surface topography of bonded CAD/CAM silica-based ceramics. Dent Mater 2020; 37:e151-e161. [PMID: 33298316 DOI: 10.1016/j.dental.2020.11.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/28/2020] [Accepted: 11/13/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate the influence of different surface treatments on biaxial flexure strength, roughness, and surface topography of lithium silicate/disilicate-based ceramics. METHODS 225 discs (∅: 12 mm; 1.2 mm - ISO 6872) were made from three ceramics: IPS e.max CAD (LD - Ivoclar Vivadent), Suprinity (LSS - Vita) and Celtra Duo (LSC - Dentsply). The samples were randomly divided into 5 groups (n = 15): no treatment (C); 10% hydrofluoric acid + silane (HF); sandblasting Al2O3 + silane (SB); silicatization + silane (SC); and self-etching ceramic primer (SEP). After surface treatment, a resin cement layer was applied to the disc surface (RelyX U200, 3M ESPE), mechanical cycled (1.2 × 106 cycles, 50 N, 3.8 Hz) and submitted to biaxial flexural strength test (1 mm/min, 1000 Kgf). Roughness, EDS and SEM were also performed. Data were analyzed by one-way ANOVA, Tukey test (5%) and Weibull. RESULTS ANOVA revealed that the "surface treatment" factor was significant for all ceramics (p < 0.05). The groups LD-HF (289.30 ± 40) LD-SEP (298. 87 ± 53.29), LSC-HF (195.51 ± 42.12), LSS-HF (269.58 ± 27.07) and LSS-SEP (207.45 ± 28.63) presented significantly higher biaxial flexure strength than respective control groups, except for the LSC-SEP (165.41 ± 33.86), which was statistically similar to the control. The Weibull modulus was significantly higher for the LD-SB, LSC-SC groups. Additionally, the LD-SB, LSC-SC and LSS-HF groups showed higher roughness compared to the other treatments. SIGNIFICANCE HF etching followed by silanization and self-etching ceramic primer are the most suitable surface treatments for lithium silicate/disilicate-based glass-ceramics.
Collapse
Affiliation(s)
- Camila Moreira Lima
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| | - Nathalia Ramos da Silva
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787 - Lagoa Nova, Natal, RN, CEP: 59056-000, Brazil.
| | - Jordana Dias Martins
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| | - Jean Soares Miranda
- Braz Cubas University, Department of Dentistry, Av. Francisco Rodrigues Filho, 1233 - Vila Mogilar, Mogi das Cruzes, SP, CEP: 08773-380, Brazil.
| | - Ricardo Tanaka
- University of São Paulo (USP), Dental School, St. João de Santa Maria, 129 - Vila Brasilina, São Paulo, SP, CEP: 04158-070, Brazil.
| | - Rodrigo Othávio de Assunção E Souza
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787 - Lagoa Nova, Natal, RN, CEP: 59056-000, Brazil.
| | - Fabíola Pessôa Pereira Leite
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| |
Collapse
|