Ahmad Azahari AFA, Wan Ab Naim WN, Md Sari NA, Lim E, Mohamed Mokhtarudin MJ. Advancement in computational simulation and validation of congenital heart disease: a review. Comput Methods Biomech Biomed Engin 2024:1-14. [PMID: 39001803 DOI: 10.1080/10255842.2024.2377338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 07/02/2024] [Indexed: 07/15/2024]
Abstract
The improvement in congenital heart disease (CHD) treatment and management has increased the life expectancy in infants. However, the long-term efficacy is difficult to assess and thus, computational modelling has been applied for evaluating this. Here, we provide an overview of the applications of computational modelling in CHD based on three categories; CHD involving large blood vessels only, heart chambers only, and CHD that occurs at multiple heart structures. We highlight the advancement of computational simulation of CHD that uses multiscale and multiphysics modelling to ensure a complete representation of the heart and circulation. We provide a brief future direction of computational modelling of CHD such as to include growth and remodelling, detailed conduction system, and occurrence of myocardial infarction. We also proposed validation technique using advanced three-dimensional (3D) printing and particle image velocimetry (PIV) technologies to improve the model accuracy.
Collapse
Affiliation(s)
| | - Wan Naimah Wan Ab Naim
- Faculty of Manufacturing and Mechatronic Engineering Technology, Universiti Malaysia Pahang, Pekan, Pahang, Malaysia
| | - Nor Ashikin Md Sari
- Division of Cardiology, Department of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Einly Lim
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohd Jamil Mohamed Mokhtarudin
- Faculty of Manufacturing and Mechatronic Engineering Technology, Universiti Malaysia Pahang, Pekan, Pahang, Malaysia
- Centre for Research in Advanced Fluid and Processes (Fluid Centre), Universiti Malaysia Pahang, Lebuhraya Tun Razak, Kuantan, Pahang, Malaysia
| |
Collapse
|
2
|
Tikenoğullar i OZ, Peirlinck M, Chubb H, Dubin AM, Kuhl E, Marsden AL. Effects of cardiac growth on electrical dyssynchrony in the single ventricle patient. Comput Methods Biomech Biomed Engin 2024; 27:1011-1027. [PMID: 37314141 PMCID: PMC10719423 DOI: 10.1080/10255842.2023.2222203] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 04/27/2023] [Accepted: 05/04/2023] [Indexed: 06/15/2023]
Abstract
Single ventricle patients, including those with hypoplastic left heart syndrome (HLHS), typically undergo three palliative heart surgeries culminating in the Fontan procedure. HLHS is associated with high rates of morbidity and mortality, and many patients develop arrhythmias, electrical dyssynchrony, and eventually ventricular failure. However, the correlation between ventricular enlargement and electrical dysfunction in HLHS physiology remains poorly understood. Here we characterize the relationship between growth and electrophysiology in HLHS using computational modeling. We integrate a personalized finite element model, a volumetric growth model, and a personalized electrophysiology model to perform controlled in silico experiments. We show that right ventricle enlargement negatively affects QRS duration and interventricular dyssynchrony. Conversely, left ventricle enlargement can partially compensate for this dyssynchrony. These findings have potential implications on our understanding of the origins of electrical dyssynchrony and, ultimately, the treatment of HLHS patients.
Collapse
Affiliation(s)
- O. Z. Tikenoğullar i
- Department of Mechanical Engineering, Stanford University, Stanford, California, USA
| | - M. Peirlinck
- Department of Biomechanical Engineering, Delft University of Technology, Delft, Netherlands
| | - H. Chubb
- Department of Pediatrics (Cardiology), Stanford University, Stanford, California, USA
| | - A. M. Dubin
- Department of Pediatrics (Cardiology), Stanford University, Stanford, California, USA
| | - E. Kuhl
- Department of Mechanical Engineering, Stanford University, Stanford, California, USA
| | - A. L. Marsden
- Department of Mechanical Engineering, Stanford University, Stanford, California, USA
- Department of Pediatrics (Cardiology), Stanford University, Stanford, California, USA
- Department of Bioengineering, Stanford University, Stanford, California, USA
- Institute for Computational and Mathematical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
3
|
Aramburu J, Ruijsink B, Chabiniok R, Pushparajah K, Alastruey J. Patient-specific closed-loop model of the fontan circulation: Calibration and validation. Heliyon 2024; 10:e30404. [PMID: 38742066 PMCID: PMC11089314 DOI: 10.1016/j.heliyon.2024.e30404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/16/2024] Open
Abstract
The Fontan circulation, designed for managing patients with a single functional ventricle, presents challenges in long-term outcomes. Computational methods offer potential solutions, yet their application in cardiology practice remains largely unexplored. Our aim was to assess the ability of a patient-specific, closed-loop, reduced-order blood flow model to simulate pulsatile blood flow in the Fontan circulation. Using one-dimensional models, we simulated the aorta, superior and inferior venae cavae, and right and left pulmonary arteries, while lumping heart chambers and remaining vessels into zero-dimensional models. The model was calibrated with patient-specific haemodynamic data from combined cardiac catheterisation and magnetic resonance exams, using a novel physics-based stepwise methodology involving simpler open-loop models. Testing on a 10-year-old, anesthetised patient, demonstrated the model's capability to replicate pulsatile pressure and flow in the larger vessels and ventricular pressure. Average relative errors in mean pressure and flow were 2.9 % and 3.6 %, with average relative point-to-point errors (RPPE) in pressure and flow at 5.2 % and 16.0 %. Comparing simulation results to measurements, mean aortic pressure and flow values were 50.7 vs. 50.4 mmHg and 41.6 vs. 41.9 ml/s, respectively, while ventricular pressure values were 28.7 vs. 27.4 mmHg. The model accurately described time-varying ventricular volume with a RPPE of 2.9 %, with mean, minimum, and maximum ventricular volume values for simulation results vs. measurements at 59.2 vs. 58.2 ml, 38.0 vs. 37.6 ml, and 76.0 vs. 74.4 ml, respectively. It provided physiologically realistic predictions of haemodynamic changes from pulmonary vasodilation and atrial fenestration opening. The new model and calibration methodology are freely available, offering a platform to virtually investigate the Fontan circulation's response to clinical interventions and explore potential mechanisms of Fontan failure. Future efforts will concentrate on broadening the model's applicability to a wider range of patient populations and clinical scenarios, as well as testing its effectiveness.
Collapse
Affiliation(s)
- Jorge Aramburu
- Universidad de Navarra, TECNUN Escuela de Ingeniería, P° Manuel Lardizabal 13, 20018, Donostia/San Sebastián, Spain
| | - Bram Ruijsink
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK
| | - Radomir Chabiniok
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK
- Division of Pediatric Cardiology, Department of Pediatrics, UT Southwestern Medical Center, Dallas, TX, USA
| | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK
- Department of Congenital Heart Disease, Evelina Children's Hospital, SE1 7EH, London, UK
| | - Jordi Alastruey
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, SE1 7EH, London, UK
| |
Collapse
|
4
|
Kaiser AD, Haidar MA, Choi PS, Sharir A, Marsden AL, Ma MR. Simulation-based design of bicuspidization of the aortic valve. J Thorac Cardiovasc Surg 2024:S0022-5223(24)00009-6. [PMID: 38211896 DOI: 10.1016/j.jtcvs.2023.12.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/05/2023] [Accepted: 12/21/2023] [Indexed: 01/13/2024]
Abstract
OBJECTIVE Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptable durability. However, most understanding of the procedure is empirical and retrospective. This work seeks to design the optimal gross morphology associated with surgical bicuspidization with simulations based on the hypothesis that modifications to the free edge length cause or relieve stenosis. METHODS Model bicuspid valves were constructed with varying free edge lengths and gross morphology. Fluid-structure interaction simulations were conducted in a single patient-specific model geometry. The models were evaluated for primary targets of stenosis and regurgitation. Secondary targets were assessed and included qualitative hemodynamics, geometric height, effective height, orifice area, and billow. RESULTS Stenosis decreased with increasing free edge length and was pronounced with free edge length less than or equal to 1.3 times the annular diameter d. With free edge length 1.5d or greater, no stenosis occurred. All models were free of regurgitation. Substantial billow occurred with free edge length 1.7d or greater. CONCLUSIONS Free edge length 1.5d or greater was required to avoid aortic stenosis in simulations. Cases with free edge length 1.7d or greater showed excessive billow and other changes in gross morphology. Cases with free edge length 1.5d to 1.6d have a total free edge length approximately equal to the annular circumference and appeared optimal. These effects should be studied in vitro and in animal studies.
Collapse
Affiliation(s)
- Alexander D Kaiser
- Division of Pediatric Cardiology, Department of Pediatrics, Stanford University, Stanford, Calif; Cardiovascular Institute, Stanford University, Stanford, Calif
| | - Moussa A Haidar
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Perry S Choi
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Amit Sharir
- Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Alison L Marsden
- Division of Pediatric Cardiology, Department of Pediatrics, Stanford University, Stanford, Calif; Cardiovascular Institute, Stanford University, Stanford, Calif; Department of Bioengineering, Stanford University, Stanford, Calif; Institute for Computational and Mathematical Engineering, Stanford University, Stanford, Calif
| | - Michael R Ma
- Cardiovascular Institute, Stanford University, Stanford, Calif; Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.
| |
Collapse
|
5
|
Yang W, Conover TA, Figliola RS, Giridharan GA, Marsden AL, Rodefeld MD. Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support. Sci Rep 2023; 13:12668. [PMID: 37542111 PMCID: PMC10403595 DOI: 10.1038/s41598-023-38559-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 07/11/2023] [Indexed: 08/06/2023] Open
Abstract
Patients with single ventricle defects undergoing the Fontan procedure eventually face Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are currently being developed as a subpulmonary power source to prevent and treat Fontan failure. Low hydraulic resistance is a critical safety requirement in the event of pump failure (0 RPM) as a modest 2 mmHg cavopulmonary pressure drop can compromise patient hemodynamics. The goal of this study is therefore to assess the passive performance of a viscous impeller pump (VIP) we are developing for Fontan patients, and validate flow simulations against in-vitro data. Two different blade heights (1.09 mm vs 1.62 mm) and a blank housing model were tested using a mock circulatory loop (MCL) with cardiac output ranging from 3 to 11 L/min. Three-dimensional flow simulations were performed and compared against MCL data. In-silico and MCL results demonstrated a pressure drop of < 2 mmHg at a cardiac output of 7 L/min for both blade heights. There was good agreement between simulation and MCL results for pressure loss (mean difference - 0.23 mmHg 95% CI [0.24-0.71]). Compared to the blank housing model, low wall shear stress area and oscillatory shear index on the pump surface were low, and mean washout times were within 2 s. This study demonstrated the low resistance characteristic of current VIP designs in the failed condition that results in clinically acceptable minimal pressure loss without increased washout time as compared to a blank housing model under normal cardiac output in Fontan patients.
Collapse
Affiliation(s)
- Weiguang Yang
- Department of Pediatrics (Cardiology), Stanford University, Stanford, CA, USA.
| | - Timothy A Conover
- Departments of Mechanical Engineering, Clemson University, Clemson, SC, USA
| | - Richard S Figliola
- Departments of Mechanical Engineering, Clemson University, Clemson, SC, USA
| | | | - Alison L Marsden
- Department of Pediatrics (Cardiology), Stanford University, Stanford, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Mark D Rodefeld
- Section of Cardiothoracic Surgery, Department of Surgery, Indiana University School of Medicine, Indianapolis, IN, USA
| |
Collapse
|
6
|
Schwarz EL, Pegolotti L, Pfaller MR, Marsden AL. Beyond CFD: Emerging methodologies for predictive simulation in cardiovascular health and disease. BIOPHYSICS REVIEWS 2023; 4:011301. [PMID: 36686891 PMCID: PMC9846834 DOI: 10.1063/5.0109400] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 12/12/2022] [Indexed: 01/15/2023]
Abstract
Physics-based computational models of the cardiovascular system are increasingly used to simulate hemodynamics, tissue mechanics, and physiology in evolving healthy and diseased states. While predictive models using computational fluid dynamics (CFD) originated primarily for use in surgical planning, their application now extends well beyond this purpose. In this review, we describe an increasingly wide range of modeling applications aimed at uncovering fundamental mechanisms of disease progression and development, performing model-guided design, and generating testable hypotheses to drive targeted experiments. Increasingly, models are incorporating multiple physical processes spanning a wide range of time and length scales in the heart and vasculature. With these expanded capabilities, clinical adoption of patient-specific modeling in congenital and acquired cardiovascular disease is also increasing, impacting clinical care and treatment decisions in complex congenital heart disease, coronary artery disease, vascular surgery, pulmonary artery disease, and medical device design. In support of these efforts, we discuss recent advances in modeling methodology, which are most impactful when driven by clinical needs. We describe pivotal recent developments in image processing, fluid-structure interaction, modeling under uncertainty, and reduced order modeling to enable simulations in clinically relevant timeframes. In all these areas, we argue that traditional CFD alone is insufficient to tackle increasingly complex clinical and biological problems across scales and systems. Rather, CFD should be coupled with appropriate multiscale biological, physical, and physiological models needed to produce comprehensive, impactful models of mechanobiological systems and complex clinical scenarios. With this perspective, we finally outline open problems and future challenges in the field.
Collapse
Affiliation(s)
- Erica L. Schwarz
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Luca Pegolotti
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Martin R. Pfaller
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Alison L. Marsden
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| |
Collapse
|
7
|
Zhang Y, Fang M, Wang Z, Liu Y, Zhang C, Wang Z, Wang H. The prediction and verification of outcome of extracardiac conduits fontan based on computational fluid dynamics simulation. Front Physiol 2022; 13:1078140. [PMID: 36505086 PMCID: PMC9729743 DOI: 10.3389/fphys.2022.1078140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/14/2022] [Indexed: 11/25/2022] Open
Abstract
Objective: This study applied preoperative computed tomography angiography (CTA) and computational fluid dynamics (CFD) simulation to predicte and verify the outcome of Y-shaped extracardiac conduits Fontan for functional single ventricle. Methods: Based on the preoperative CTA data of functional single ventricle (FSV), 4 types of spatial structures of extracardiac conduits were designed for 4 experimental groups: Group A, a traditional TCPC group (20 mm); Group B, a diameter-preserving Y-shaped TCPC (YCPC) group (branch 10 mm); Group C, YCPC group (branch 12 mm); and Group D, an area-preserving YCPC group (branch14 mm). Four indicators including flow velocity, pressure gradient (PG), energy efficiency and inferior vena cava (IVC) blood flow distribution were compared. The optimal procedure was applied. The radionuclide lung perfusion, CTA, echocardiography, cardiovascular angiography and catheterization were performed postoperatively. Results: There were the lowest PG, the lowest flow velocity of branches, the highest energy efficiency, and a relatively balanced and stable distribution of IVC flow for group D. Subsequently, the group D, a handcrafted Y-shaped conduit (14 mm) was used for the YCPC procedure. There was no postoperative PG between the conduit and pulmonary artery with normal pressure and resistance. IVC flow was distributed uniformly. Conclusion: CTA-based CFD provided more guidance for the clinical application of TCPC. A comprehensive surgical design could bring good postoperative outcome. Area-preserving YCPC has more advantages than TCPC and the diameter-preserving YCPC. The study effectively improved the feasibility of clinical applications of YCPC.
Collapse
|
8
|
Liu X, Aslan S, Kim B, Warburton L, Jackson D, Muhuri A, Subramanian A, Mass P, Cleveland V, Loke YH, Hibino N, Olivieri L, Krieger A. Computational Fontan Analysis: Preserving Accuracy While Expediting Workflow. World J Pediatr Congenit Heart Surg 2022; 13:293-301. [PMID: 35446218 DOI: 10.1177/21501351211073619] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Background: Postoperative outcomes of the Fontan operation have been linked to geometry of the cavopulmonary pathway, including graft shape after implantation. Computational fluid dynamics (CFD) simulations are used to explore different surgical options. The objective of this study is to perform a systematic in vitro validation for investigating the accuracy and efficiency of CFD simulation to predict Fontan hemodynamics. Methods: CFD simulations were performed to measure indexed power loss (iPL) and hepatic flow distribution (HFD) in 10 patient-specific Fontan models, with varying mesh and numerical solvers. The results were compared with a novel in vitro flow loop setup with 3D printed Fontan models. A high-resolution differential pressure sensor was used to measure the pressure drop for validating iPL predictions. Microparticles with particle filtering system were used to measure HFD. The computational time was measured for a representative Fontan model with different mesh sizes and numerical solvers. Results: When compared to in vitro setup, variations in CFD mesh sizes had significant effect on HFD (P = .0002) but no significant impact on iPL (P = .069). Numerical solvers had no significant impact in both iPL (P = .50) and HFD (P = .55). A transient solver with 0.5 mm mesh size requires computational time 100 times more than a steady solver with 2.5 mm mesh size to generate similar results. Conclusions: The predictive value of CFD for Fontan planning can be validated against an in vitro flow loop. The prediction accuracy can be affected by the mesh size, model shape complexity, and flow competition.
Collapse
Affiliation(s)
- Xiaolong Liu
- Department of Mechanical Engineering, 1466Johns Hopkins University, Baltimore, MD, USA.,Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Seda Aslan
- Department of Mechanical Engineering, 1466Johns Hopkins University, Baltimore, MD, USA.,Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Byeol Kim
- Department of Mechanical Engineering, 1466Johns Hopkins University, Baltimore, MD, USA.,Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Linnea Warburton
- Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Derrick Jackson
- Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Abir Muhuri
- Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Akshay Subramanian
- Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| | - Paige Mass
- Sheikh Zayed Institute for Pediatric Surgical Innovation, 8404Children's National Medical Center, Washington, DC, USA
| | - Vincent Cleveland
- Sheikh Zayed Institute for Pediatric Surgical Innovation, 8404Children's National Medical Center, Washington, DC, USA
| | - Yue-Hin Loke
- 8404Division of Cardiology, Children's National Medical Center, Washington, DC, USA
| | - Narutoshi Hibino
- 2462Department of Cardiac Surgery, University of Chicago/21880Advocate Children's Hospital, Chicago, IL, USA
| | - Laura Olivieri
- Sheikh Zayed Institute for Pediatric Surgical Innovation, 8404Children's National Medical Center, Washington, DC, USA.,8404Division of Cardiology, Children's National Medical Center, Washington, DC, USA
| | - Axel Krieger
- Department of Mechanical Engineering, 1466Johns Hopkins University, Baltimore, MD, USA.,Department of Mechanical Engineering, 1068University of Maryland, College Park, MD, USA
| |
Collapse
|
9
|
Tobin N, Good BC, Plasencia JD, Fogel MA, Weiss WJ, Manning KB. Computational Investigation of Anastomosis Options of a Right-Heart Pump to Patient Specific Pulmonary Arteries. Ann Biomed Eng 2022; 50:929-940. [PMID: 35451680 DOI: 10.1007/s10439-022-02969-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 04/12/2022] [Indexed: 11/30/2022]
Abstract
Patients with Fontan circulation have increased risk of heart failure, but are not always candidates for heart transplant, leading to the development of the subpulmonic Penn State Fontan Circulation Assist Device. The aim of this study was to use patient-specific computational fluid dynamics simulations to evaluate anastomosis options for implanting this device. Simulations were performed of the pre-surgical anatomy as well as four surgical options: a T-junction and three Y-grafts. Cases were evaluated based on several fluid-dynamic quantities. The impact of imbalanced left-right pulmonary flow distribution was also investigated. Results showed that a 12-mm Y-graft was the most energy efficient. However, an 8-mm graft showed more favorable wall shear stress distribution, indicating lower risk of thrombosis and endothelial damage. The 8-mm Y-grafts also showed a more balanced pulmonary flow split, and lower residence time, also indicating lower thrombosis risk. The relative performance of the surgical options was largely unchanged whether or not the pulmonary vascular resistance remained imbalanced post-implantation.
Collapse
Affiliation(s)
- Nicolas Tobin
- Department of Biomedical Engineering, The Pennsylvania State University, 122 Chemical and Biomedical Engineering Building, University Park, PA, 16802-4400, USA
| | - Bryan C Good
- Department of Biomedical Engineering, The Pennsylvania State University, 122 Chemical and Biomedical Engineering Building, University Park, PA, 16802-4400, USA
| | | | - Mark A Fogel
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, 19104, USA
| | - William J Weiss
- Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, 17033, USA
| | - Keefe B Manning
- Department of Biomedical Engineering, The Pennsylvania State University, 122 Chemical and Biomedical Engineering Building, University Park, PA, 16802-4400, USA. .,Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, 17033, USA.
| |
Collapse
|
10
|
Kim B, Nguyen P, Loke YH, Cleveland V, Liu X, Mass P, Hibino N, Olivieri L, Krieger A. CorFix: Virtual Reality Cardiac Surgical Planning Software for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study (Preprint). JMIR Cardio 2021; 6:e35488. [PMID: 35713940 PMCID: PMC9250062 DOI: 10.2196/35488] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 05/05/2022] [Accepted: 05/17/2022] [Indexed: 11/17/2022] Open
Abstract
Background Patients with single ventricle heart defects receive 3 stages of operations culminating in the Fontan procedure. During the Fontan procedure, a vascular graft is sutured between the inferior vena cava and pulmonary artery to divert deoxygenated blood flow to the lungs via passive flow. Customizing the graft configuration can maximize the long-term benefits. However, planning patient-specific procedures has several challenges, including the ability for physicians to customize grafts and evaluate their hemodynamic performance. Objective The aim of this study was to develop a virtual reality (VR) Fontan graft modeling and evaluation software for physicians. A user study was performed to achieve 2 additional goals: (1) to evaluate the software when used by medical doctors and engineers, and (2) to explore the impact of viewing hemodynamic simulation results in numerical and graphical formats. Methods A total of 5 medical professionals including 4 physicians (1 fourth-year resident, 1 third-year cardiac fellow, 1 pediatric intensivist, and 1 pediatric cardiac surgeon) and 1 biomedical engineer voluntarily participated in the study. The study was pre-scripted to minimize the variability of the interactions between the experimenter and the participants. All participants were trained to use the VR gear and our software, CorFix. Each participant designed 1 bifurcated and 1 tube-shaped Fontan graft for a single patient. A hemodynamic performance evaluation was then completed, allowing the participants to further modify their tube-shaped design. The design time and hemodynamic performance for each graft design were recorded. At the end of the study, all participants were provided surveys to evaluate the usability and learnability of the software and rate the intensity of VR sickness. Results The average times for creating 1 bifurcated and 1 tube-shaped graft after a single 10-minute training session were 13.40 and 5.49 minutes, respectively, with 3 out 5 bifurcated and 1 out of 5 tube-shaped graft designs being in the benchmark range of hepatic flow distribution. Reviewing hemodynamic performance results and modifying the tube-shaped design took an average time of 2.92 minutes. Participants who modified their tube-shaped graft designs were able to improve the nonphysiologic wall shear stress (WSS) percentage by 7.02%. All tube-shaped graft designs improved the WSS percentage compared to the native surgical case of the patient. None of the designs met the benchmark indexed power loss. Conclusions VR graft design software can quickly be taught to physicians with no engineering background or VR experience. Improving the CorFix system could improve performance of the users in customizing and optimizing grafts for patients. With graphical visualization, physicians were able to improve WSS percentage of a tube-shaped graft, lowering the chance of thrombosis. Bifurcated graft designs showed potential strength in better flow split to the lungs, reducing the risk for pulmonary arteriovenous malformations.
Collapse
Affiliation(s)
- Byeol Kim
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Phong Nguyen
- Department of Computer Science, University of Maryland, College Park, MD, United States
| | - Yue-Hin Loke
- Division of Cardiology, Children's National Hospital, Washington, DC, United States
| | - Vincent Cleveland
- Division of Cardiology, Children's National Hospital, Washington, DC, United States
| | - Xiaolong Liu
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Paige Mass
- Division of Cardiology, Children's National Hospital, Washington, DC, United States
| | - Narutoshi Hibino
- Department of Surgery, University of Chicago, Chicago, IL, United States
| | - Laura Olivieri
- Division of Cardiology, Children's National Hospital, Washington, DC, United States
| | - Axel Krieger
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States
| |
Collapse
|
11
|
Schwarz EL, Kelly JM, Blum KM, Hor KN, Yates AR, Zbinden JC, Verma A, Lindsey SE, Ramachandra AB, Szafron JM, Humphrey JD, Shin'oka T, Marsden AL, Breuer CK. Hemodynamic performance of tissue-engineered vascular grafts in Fontan patients. NPJ Regen Med 2021; 6:38. [PMID: 34294733 PMCID: PMC8298568 DOI: 10.1038/s41536-021-00148-w] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 06/11/2021] [Indexed: 02/06/2023] Open
Abstract
In the field of congenital heart surgery, tissue-engineered vascular grafts (TEVGs) are a promising alternative to traditionally used synthetic grafts. Our group has pioneered the use of TEVGs as a conduit between the inferior vena cava and the pulmonary arteries in the Fontan operation. The natural history of graft remodeling and its effect on hemodynamic performance has not been well characterized. In this study, we provide a detailed analysis of the first U.S. clinical trial evaluating TEVGs in the treatment of congenital heart disease. We show two distinct phases of graft remodeling: an early phase distinguished by rapid changes in graft geometry and a second phase of sustained growth and decreased graft stiffness. Using clinically informed and patient-specific computational fluid dynamics (CFD) simulations, we demonstrate how changes to TEVG geometry, thickness, and stiffness affect patient hemodynamics. We show that metrics of patient hemodynamics remain within normal ranges despite clinically observed levels of graft narrowing. These insights strengthen the continued clinical evaluation of this technology while supporting recent indications that reversible graft narrowing can be well tolerated, thus suggesting caution before intervening clinically.
Collapse
Affiliation(s)
- Erica L Schwarz
- Department of Bioengineering, Stanford University, Stanford, CA, USA.
| | - John M Kelly
- Center for Regenerative Medicine, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH, USA
- The Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
| | - Kevin M Blum
- Center for Regenerative Medicine, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Kan N Hor
- The Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
- Department of Pediatrics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Andrew R Yates
- The Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
- Department of Pediatrics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Jacob C Zbinden
- Center for Regenerative Medicine, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Aekaansh Verma
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Stephanie E Lindsey
- Department of Bioengineering, Stanford University, Stanford, CA, USA
- Department of Pediatrics, Stanford University, Stanford, CA, USA
| | | | - Jason M Szafron
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Toshiharu Shin'oka
- Center for Regenerative Medicine, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH, USA
- The Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
- Department of Cardiothoracic Surgery, Nationwide Children's Hospital, Columbus, OH, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Stanford, CA, USA
- Department of Pediatrics, Stanford University, Stanford, CA, USA
| | - Christopher K Breuer
- Center for Regenerative Medicine, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH, USA
- Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
- Department of Surgery, Nationwide Children's Hospital, Columbus, OH, USA
| |
Collapse
|
12
|
Engineering Perspective on Cardiovascular Simulations of Fontan Hemodynamics: Where Do We Stand with a Look Towards Clinical Application. Cardiovasc Eng Technol 2021; 12:618-630. [PMID: 34114202 DOI: 10.1007/s13239-021-00541-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 04/30/2021] [Indexed: 01/02/2023]
Abstract
BACKGROUND Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.
Collapse
|
13
|
Rijnberg FM, van der Woude SFS, van Assen HC, Juffermans JF, Hazekamp MG, Jongbloed MRM, Kenjeres S, Lamb HJ, Westenberg JJM, Wentzel JJ, Roest AAW. Non-uniform mixing of hepatic venous flow and inferior vena cava flow in the Fontan conduit. J R Soc Interface 2021; 18:20201027. [PMID: 33823607 PMCID: PMC8086942 DOI: 10.1098/rsif.2020.1027] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Fontan patients require a balanced hepatic blood flow distribution (HFD) to prevent pulmonary arteriovenous malformations. Currently, HFD is quantified by tracking Fontan conduit flow, assuming hepatic venous (HV) flow to be uniformly distributed within the Fontan conduit. However, this assumption may be unvalid leading to inaccuracies in HFD quantification with potential clinical impact. The aim of this study was to (i) assess the mixing of HV flow and inferior vena caval (IVC) flow within the Fontan conduit and (ii) quantify HFD by directly tracking HV flow and quantitatively comparing results with the conventional approach. Patient-specific, time-resolved computational fluid dynamic models of 15 total cavopulmonary connections were generated, including the HV and subhepatic IVC. Mixing of HV and IVC flow, on a scale between 0 (no mixing) and 1 (perfect mixing), was assessed at the caudal and cranial Fontan conduit. HFD was quantified by tracking particles from the caudal (HFDcaudal conduit) and cranial (HFDcranial conduit) conduit and from the hepatic veins (HFDHV). HV flow was non-uniformly distributed at both the caudal (mean mixing 0.66 ± 0.13) and cranial (mean 0.79 ± 0.11) level within the Fontan conduit. On a cohort level, differences in HFD between methods were significant but small; HFDHV (51.0 ± 20.6%) versus HFDcaudal conduit (48.2 ± 21.9%, p = 0.033) or HFDcranial conduit (48.0 ± 21.9%, p = 0.044). However, individual absolute differences of 8.2–14.9% in HFD were observed in 4/15 patients. HV flow is non-uniformly distributed within the Fontan conduit. Substantial individual inaccuracies in HFD quantification were observed in a subset of patients with potential clinical impact.
Collapse
Affiliation(s)
- Friso M Rijnberg
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Hans C van Assen
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Joe F Juffermans
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Mark G Hazekamp
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Monique R M Jongbloed
- Department of Cardiology and Anatomy and Embryology, Leiden University Medical Center, Leiden, The Netherlands
| | - Sasa Kenjeres
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology and J. M. Burgerscentrum Research School for Fluid Mechanics, Delft, The Netherlands
| | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jolanda J Wentzel
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
| | - Arno A W Roest
- Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
14
|
Tran K, Yang W, Marsden A, Lee JT. Patient-specific computational flow modelling for assessing hemodynamic changes following fenestrated endovascular aneurysm repair. JVS Vasc Sci 2021; 2:53-69. [PMID: 34258601 PMCID: PMC8274562 DOI: 10.1016/j.jvssci.2020.11.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective This study aimed to develop an accessible patient-specific computational flow modelling pipeline for evaluating the hemodynamic performance of fenestrated endovascular aneurysm repair (fEVAR), with the hypothesis that computational flow modelling can detect aortic branch hemodynamic changes associated with fEVAR graft implantation. Methods Patients who underwent fEVAR for juxtarenal aortic aneurysms with the Cook ZFEN were retrospectively selected. Using open-source SimVascular software, preoperative and postoperative visceral aortic anatomy was manually segmented from computed tomography angiograms. Three-dimensional geometric models were then discretized into tetrahedral finite element meshes. Patient-specific pulsatile in-flow conditions were derived from known supraceliac aortic flow waveforms and adjusted for patient body surface area, average resting heart rate, and blood pressure. Outlet boundary conditions consisted of three-element Windkessel models approximated from physiologic flow splits. Rigid wall flow simulations were then performed on preoperative and postoperative models with the same inflow and outflow conditions. We used SimVascular's incompressible Navier-Stokes solver to perform blood flow simulations on a cluster using 72 cores. Results Preoperative and postoperative flow simulations were performed for 10 patients undergoing fEVAR with a total of 30 target vessels (20 renal stents, 10 mesenteric scallops). Postoperative models required a higher mean number of mesh elements to reach mesh convergence (3.2 ± 1.8 × 106 vs 2.6 ± 1.1 × 106; P = .005) with a longer mean computational time (10.3 ± 6.3 hours vs 7.8 ± 3.5 hours; P = .04) compared with preoperative models. fEVAR was associated with small but statistically significant increases in mean peak proximal aortic arterial pressure (140.3 ± 11.0 mm Hg vs 136.9 ± 8.7 mm Hg; P = .02) and peak renal artery pressure (131.6 ± 14.8 mm Hg vs 128.9 ± 11.8 mm Hg; P = .04) compared with preoperative simulations. No differences were observed in peak pressure in the celiac, superior mesenteric, or distal aortic arteries (P = .17-.96). When measuring blood flow, the only observed difference was an increase in peak renal flow rate after fEVAR (17.5 ± 3.8 mL/s vs 16.9 ± 3.5 mL/s; P = .04). fEVAR was not associated with changes in the mean pressure or the mean flow rate in the celiac, superior mesenteric, or renal arteries (P = .06-.98). Stenting of the renal arteries did not induce significant changes time-averaged wall shear stress in the proximal renal artery (23.4 ± 8.1 dynes/cm2 vs 23.2 ± 8.4 dynes/cm2; P = .98) or distal renal artery (32.7 ± 13.9 dynes/cm2 vs 29.6 ± 11.8 dynes/cm2; P = .23). In addition, computational visualization of cross-sectional velocity profiles revealed low flow disturbances associated with protrusion of renal graft fabric into the aortic lumen. Conclusions In a pilot study involving a selective cohort of patients who underwent uncomplicated fEVAR, patient-specific flow modelling was a feasible method for assessing the hemodynamic performance of various two-vessel fenestrated device configurations and revealed subtle differences in computationally derived peak branch pressure and blood flow rates. Structural changes in aortic flow geometry after fEVAR do not seem to affect computationally estimated renovisceral branch perfusion or wall shear stress adversely. Additional studies with invasive angiography or phase contrast magnetic resonance imaging are required to clinically validate these findings. (JVS–Vascular Science 2021;2:53-69.) Clinical Relevance Using a computational flow modelling for assessing the hemodynamic performance of fenestrated endovascular aneurysm repair (fEVAR), this real-world, patient-specific study included 10 participants and found that structural changes in aortic flow geometry after fEVAR did not seem to adversely impact estimated renal or visceral branch perfusion metrics (eg, peak and mean arterial pressure and flow rates) or wall shear stress. These findings overall support the ongoing clinical use of commercially available fEVAR devices for repair of juxtarenal aortic aneurysms, and provides a computational framework for future evaluation of fEVAR configurations in a preoperative or postoperative settings.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford University.,Cardiovascular Institute, Stanford University
| | - Weiguang Yang
- Department of Pediatrics (Cardiology), Stanford University
| | - Alison Marsden
- Department of Pediatrics (Cardiology), Stanford University.,Department of Bioengineering, Stanford University
| | - Jason T Lee
- Division of Vascular Surgery, Stanford University.,Cardiovascular Institute, Stanford University
| | | |
Collapse
|
15
|
Wei ZA, Ratnayaka K, Si B, Singh-Gryzbon S, Cetatoiu MA, Fogel MA, Slesnick T, Yoganathan AP, Nigro JJ. An Anterior Anastomosis for the Modified Fontan Connection: A Hemodynamic Analysis. Semin Thorac Cardiovasc Surg 2021; 33:816-823. [PMID: 33662555 DOI: 10.1053/j.semtcvs.2021.01.056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 01/05/2021] [Indexed: 12/25/2022]
Abstract
This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.
Collapse
Affiliation(s)
- Zhenglun Alan Wei
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia; Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, Massachusetts
| | - Kanishka Ratnayaka
- Division of Pediatric Cardiology, Rady Children's Hospital and UC San Diego School of Medicine, San Diego, California
| | - Biao Si
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | - Shelly Singh-Gryzbon
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | | | - Mark A Fogel
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Timothy Slesnick
- Emory University School of Medicine, Children's Healthcare of Atlanta, Atlanta, Georgia
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia.
| | - John J Nigro
- Division of Cardiovascular Surgery, Rady Children's Hospital and UC San Diego School of Medicine, San Diego, California
| |
Collapse
|
16
|
Non-Newtonian Effects on Patient-Specific Modeling of Fontan Hemodynamics. Ann Biomed Eng 2020; 48:2204-2217. [PMID: 32372365 DOI: 10.1007/s10439-020-02527-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 04/29/2020] [Indexed: 12/15/2022]
Abstract
The Fontan procedure is a common palliative surgery for congenital single ventricle patients. In silico and in vitro patient-specific modeling approaches are widely utilized to investigate potential improvements of Fontan hemodynamics that are related to long-term complications. However, there is a lack of consensus regarding the use of non-Newtonian rheology, warranting a systematic investigation. This study conducted in silico patient-specific modeling for twelve Fontan patients, using a Newtonian and a non-Newtonian model for each patient. Differences were quantified by examining clinically relevant metrics: indexed power loss (iPL), indexed viscous dissipation rate (iVDR), hepatic flow distribution (HFD), and regions of low wall shear stress (AWSS). Four sets of "non-Newtonian importance factors" were calculated to explore their effectiveness in identifying the non-Newtonian effect. No statistical differences were observed in iPL, iVDR, and HFD between the two models at the population-level, but large inter-patient variations exist. Significant differences were detected regarding AWSS, and its correlations with non-Newtonian importance factors were discussed. Additionally, simulations using the non-Newtonian model were computationally faster than those using the Newtonian model. These findings distinguish good importance factors for identifying non-Newtonian rheology and encourage the use of a non-Newtonian model to assess Fontan hemodynamics.
Collapse
|
17
|
Ebrahimi P, Youssef D, Salve G, Ayer J, Dehghani F, Fletcher DF, Winlaw DS. Evaluation of personalized right ventricle to pulmonary artery conduits using in silico design and computational analysis of flow. JTCVS OPEN 2020; 1:33-48. [PMID: 36003197 PMCID: PMC9390144 DOI: 10.1016/j.xjon.2020.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Revised: 11/09/2019] [Accepted: 02/03/2020] [Indexed: 11/28/2022]
Abstract
Objectives Right ventricle to pulmonary artery (RV-PA) conduits are required for the surgical management of pulmonary atresia with ventricular septal defect and truncus arteriosus. Bioengineered RV-PA connections may address some of the shortcomings of homografts and xenografts, such as lack of growth potential and structural deterioration and may be manufactured to accommodate patient-specific anatomy. The aim of this study was to develop a methodology for in silico patient-specific design and analysis of RV-PA conduits. Methods Cross-sectional imaging was obtained from patients with truncus arteriosus (n = 5) and pulmonary atresia with ventricular septal defect (n = 5) who underwent complete repair with a RV-PA conduit. Three-dimensional models of the heart were constructed by segmentation of the right ventricle, existing conduit, branch pulmonary arteries, and surrounding structures. A customized conduit design for each patient was proposed. Computational fluid dynamics analysis was performed and outputs, including wall shear stress and energy loss, were used to compare the performance of the existing conduits and the customized geometries. Results In this study, a methodology for patient-specific analysis of RV-PA conduit in silico was developed. The results of simulations for 10 patients showed between 23% and 56% decrease in the average wall shear stress and between 24% and 87% reduction in average power requirements in customized designs compared with the stenosed conduits, translating into better hemodynamic performance. Conclusions Creation of an optimal conduit for an individual patient can be achieved using surgeon-guided design and computational fluid dynamics analysis. Manufacture of personalized RV-PA conduits may obviate the need for surgical customization to accommodate existing materials and provide superior long-term outcomes.
Collapse
Affiliation(s)
- Pegah Ebrahimi
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia
- Heart Centre for Children, The Children's Hospital at Westmead, Sydney, Australia
| | - David Youssef
- Heart Centre for Children, The Children's Hospital at Westmead, Sydney, Australia
| | - Gananjay Salve
- Heart Centre for Children, The Children's Hospital at Westmead, Sydney, Australia
| | - Julian Ayer
- Heart Centre for Children, The Children's Hospital at Westmead, Sydney, Australia
- Faculty of Medicine and Health, Discipline of Paediatrics and Child Health, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Fariba Dehghani
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia
| | - David F. Fletcher
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia
| | - David S. Winlaw
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, Australia
- Faculty of Medicine and Health, Discipline of Paediatrics and Child Health, Sydney Medical School, The University of Sydney, Sydney, Australia
- Address for reprints: David S. Winlaw, MBBS, MD, FRACS, Heart Centre for Children, The Children's Hospital at Westmead, Locked Bag 4001, Corner Hawkesbury Rd and Hainsworth St, Westmead, 2145, Sydney, Australia.
| |
Collapse
|
18
|
Contijoch F, Li B, Yang W, Silva-Sepulveda JA, Vodkin I, Printz B, Vavinskaya V, Hegde S, Marsden A, El-Sabrout H, Alshawabkeh L, Moore JW, El-Said H. Exercise MRI highlights heterogeneity in cardiovascular mechanics among patients with Fontan circulation: proposed protocol for routine evaluation. J Thorac Dis 2020; 12:1204-1212. [PMID: 32274201 PMCID: PMC7139092 DOI: 10.21037/jtd.2019.09.59] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 09/17/2019] [Indexed: 11/30/2022]
Abstract
Single ventricle physiology and palliation via the Fontan operation lead to a series of cardiovascular changes. In addition, organs such as the kidneys and liver have been shown to experience insults and subsequent injury. This has led to routine surveillance of patients. We present findings from a small cohort of patients that was deeply phenotyped to illustrate the need for comprehensive evaluation. A cohort of four Fontan patients with fairly high cardiovascular function was recruited 5-10 years post-Fontan. Patients underwent a rigorous clinical work-up after which a research MRI scan was performed during which (I) data were obtained during exercise to evaluate changes in stroke volume during supine exercise and (II) magnetic resonance angiograms with phase-contrast images were obtained for computational modeling of flows through the Fontan circulation at rest. Clinical measures were consistent with a fairly homogeneous high function cohort (peak oxygen consumption >20 mL/kg/min, robust response to exercise, peak ventilatory efficiency below levels associated with heart failure, MR-derived ejection fraction >50%). Liver evaluation did not reveal clear signs of cirrhosis or extensive fibrosis. However, we observed considerable variability (27-162%) in the increase in stroke index with exercise [100%±64% increase, 53.9±17.4 mL/beat m2 (rest), 101.1±20.7 mL/beat m2, (exercise)]. Computational flow modeling at rest in two patients also showed marked differences in flow distribution and shear stress. We report marked differences in both changes in stroke index during an exercise MRI protocol as well as computational flow patterns at rest suggesting different compensation strategies may be associated with high functioning Fontan patients. The observed heterogeneity illustrates the need for deep phenotyping to capture patient-specific adaptive mechanisms.
Collapse
Affiliation(s)
- Francisco Contijoch
- Department of Bioengineering, UC San Diego, La Jolla CA, USA
- Department of Radiology, UC San Diego, La Jolla CA, USA
| | - Bochao Li
- Department of Bioengineering, UC San Diego, La Jolla CA, USA
| | - Weiguang Yang
- Department of Pediatrics, Stanford University, Palo Alto, CA, USA
| | | | - Irine Vodkin
- Department of Medicine, UC San Diego, La Jolla, CA, USA
| | - Beth Printz
- Department of Pediatric Cardiology, Rady Children’s Hospital, San Diego, CA, USA
| | | | - Sanjeet Hegde
- Department of Pediatric Cardiology, Rady Children’s Hospital, San Diego, CA, USA
| | - Alison Marsden
- Department of Pediatrics, Stanford University, Palo Alto, CA, USA
- Department of Bioengineering, Stanford University, Palo Alto, CA, USA
| | - Hannah El-Sabrout
- Department of Society and Genetics, UC Los Angeles, Los Angeles, CA, USA
| | | | - John W. Moore
- Department of Pediatric Cardiology, Rady Children’s Hospital, San Diego, CA, USA
| | - Howaida El-Said
- Department of Pediatric Cardiology, Rady Children’s Hospital, San Diego, CA, USA
| |
Collapse
|
19
|
Chen X, Yuan H, Liu J, Zhang N, Zhou C, Huang M, Jian Q, Zhuang J. Hemodynamic Effects of Additional Pulmonary Blood Flow on Glenn and Fontan Circulation. Cardiovasc Eng Technol 2020; 11:268-282. [PMID: 32072439 DOI: 10.1007/s13239-020-00459-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 02/10/2020] [Indexed: 10/25/2022]
Abstract
PURPOSE Additional pulmonary blood flow (APBF) can provide better pulsating blood flow and systemic arterial oxygen saturation, while low blood pulsation and low oxygen saturation are defects of the Fontan and Glenn procedure. Studying the hemodynamic effect of APBF is beneficial for clinical decisions. This study aimed to explore the effect on particle washout, as well as the differences among the sensitivities of both different hemodynamic parameters and different procedures to APBF. METHODS The patient-specific clinical datasets of a patient who underwent bilateral bidirectional Glenn (BBDG) with APBF were enrolled in this study, and using these datasets, Glenn- and Fontan-type artery models were reconstructed. A series of parameters, including the total caval flow pulsatility index (TCPI), indexed energy loss (iPL), wall shear stress (WSS), systemic arterial oxygen saturation (Satart), particle washout time (WOT), pressure in the right superior vena cava (PRSVC), pulmonary flow distribution (PFD) and hepatic flow distribution (HFD), were computed from computational fluid dynamic (CFD) simulation to evaluate the hemodynamic effect of APBF. RESULTS The result showed that APBF led to better iPL and Satart but worse PRSVC and heart load accompanied by a great impact on HFD, making hepatic flow easier to perfuse the side without MPA and APBF. The increase in the APBF rate also effectively results in larger flow pulsation, region velocity, and wall shear stress and lower WOT, and this effect may be more effective for patients with persistent left superior vena cava (PLSVC). However, APBF might have little effect on PFD. Furthermore, APBF might affect WOT, iPL and HFD more significantly than PRSVC and has a greater improvement effect in patients with poorer iPL and WOT. CONCLUSIONS Moderate APBF is not only a measure to promote pulmonary artery growth and systemic arterial oxygen saturation but also an effective method against endothelial dysfunction and thrombosis. However, moderate APBF is patient-specific and should be determined based on hemodynamic preference that leads to desired patient outcomes, and care should be taken to prevent PRSVC and heart load from being too high as well as an imbalance in HFD.
Collapse
Affiliation(s)
- Xiangyu Chen
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510000, China
| | - Haiyun Yuan
- Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Cardiovascular Surgery, Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangzhou, 510000, China
| | - Jiawei Liu
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510000, China
| | - Neichuan Zhang
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510000, China
| | - Chengbin Zhou
- Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Cardiovascular Surgery, Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangzhou, 510000, China
| | - Meiping Huang
- Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Catheterization Lab, Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Qifei Jian
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510000, China.
| | - Jian Zhuang
- Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Cardiovascular Surgery, Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangzhou, 510000, China.
| |
Collapse
|
20
|
Role of surgeon intuition and computer-aided design in Fontan optimization: A computational fluid dynamics simulation study. J Thorac Cardiovasc Surg 2020; 160:203-212.e2. [PMID: 32057454 DOI: 10.1016/j.jtcvs.2019.12.068] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 11/27/2019] [Accepted: 12/13/2019] [Indexed: 01/14/2023]
Abstract
OBJECTIVE Customized Fontan designs, generated by computer-aided design (CAD) and optimized by computational fluid dynamics simulations, can lead to novel, patient-specific Fontan conduits unconstrained by off-the-shelf grafts. The relative contributions of both surgical expertise and CAD to Fontan optimization have not been addressed. In this study, we assessed hemodynamic performance of Fontans designed by both surgeon's unconstrained modeling (SUM) and by CAD. METHODS Ten cardiac magnetic resonance imaging datasets were used to create 3-dimensional (3D) models of Fontans. Baseline computational fluid dynamics simulations assessed Fontan indexed power loss (iPL), hepatic flow distribution, and percentage of conduit surface area with abnormally low wall shear stress for venous flow (<1 dyne/cm2). Fontans not meeting thresholds were redesigned using 2 methods: SUM (ie, original venous anatomy without the Fontan was 3D printed and sent to surgeon for Fontan redesign with clay modeling) and CAD (ie, the same 3D geometry was sent to engineers for iterative Fontan redesign guided by computational fluid dynamics). Both groups were blinded to each other's results. RESULTS Eight Fontans were redesigned by SUM and CAD methods. Both SUM and CAD redesigns met iPL thresholds. SUM had lower iPL, whereas CAD demonstrated balanced hepatic flow distribution and lower wall shear stress percentage. Wall shear stress percentage shared an inverse relationship with iPL, preventing oversized Fontan designs. CONCLUSIONS Customized Fontan conduits with low iPL can be created by either a surgeon or CAD. CAD can also improve hepatic flow distribution and prevent oversized Fontan designs. Future studies should investigate workflows that combine SUM and CAD to optimize Fontan conduits.
Collapse
|
21
|
Cheng AL, Wee CP, Pahlevan NM, Wood JC. A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow. Am J Physiol Heart Circ Physiol 2019; 317:H1243-H1253. [PMID: 31585044 DOI: 10.1152/ajpheart.00296.2019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The Fontan procedure for univentricular heart defects creates a nonphysiologic circulation where systemic venous blood drains directly into the pulmonary arteries, leading to multiorgan dysfunction secondary to chronic low-shear nonpulsatile pulmonary blood flow and central venous hypertension. Although blood viscosity increases exponentially in this low-shear environment, the role of shear-dependent ("non-Newtonian") blood viscosity in this pathophysiology is unclear. We studied three-dimensional (3D)-printed Fontan models in an in vitro flow loop with a Philips 3-T magnetic resonance imaging (MRI) scanner. A 4D flow phase-contrast sequence was used to acquire a time-varying 3D velocity field for each experimental condition. On the basis of blood viscosity of a cohort of patients who had undergone the Fontan procedure, it was decided to use 0.04% xanthan gum as a non-Newtonian blood analog; 45% glycerol was used as a Newtonian control fluid. MRI data were analyzed using GTFlow and MATLAB software. The primary outcome, power loss, was significantly higher with the Newtonian fluid [14.8 (13.3, 16.4) vs. 8.1 (6.4, 9.8)%, medians with 95% confidence interval, P < 0.0001]. The Newtonian fluid also demonstrated marginally higher right pulmonary artery flow, marginally lower shear stress, and a trend toward higher caval flow mixing. Outcomes were modulated by Fontan model complexity, cardiac output, and caval flow ratio. Vortexes, helical flow, and stagnant flow were more prevalent with the non-Newtonian fluid. Our data demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.NEW & NOTEWORTHY Although blood viscosity increases exponentially in low-shear environments, the role of shear-dependent ("non-Newtonian") blood viscosity in the pathophysiology of the low-shear Fontan circulation is unclear. We demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.
Collapse
Affiliation(s)
- Andrew L Cheng
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Choo Phei Wee
- Biostatistics Core, Children's Hospital Los Angeles, Los Angeles, California
| | - Niema M Pahlevan
- Keck School of Medicine, University of Southern California, Los Angeles, California.,Department of Aerospace and Mechanical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| | - John C Wood
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| |
Collapse
|
22
|
Naci H, Salcher-Konrad M, Mcguire A, Berger F, Kuehne T, Goubergrits L, Muthurangu V, Wilson B, Kelm M. Impact of predictive medicine on therapeutic decision making: a randomized controlled trial in congenital heart disease. NPJ Digit Med 2019; 2:17. [PMID: 31304365 PMCID: PMC6550204 DOI: 10.1038/s41746-019-0085-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 02/01/2019] [Indexed: 11/09/2022] Open
Abstract
Computational modelling has made significant progress towards clinical application in recent years. In addition to providing detailed diagnostic data, these methods have the potential to simulate patient-specific interventions and to predict their outcome. Our objective was to evaluate to which extent patient-specific modelling influences treatment decisions in coarctation of the aorta (CoA), a common congenital heart disease. We selected three cases with CoA, two of which had borderline indications for intervention according to current clinical guidelines. The third case was not indicated for intervention according to guidelines. For each case, we generated two separate datasets. First dataset included conventional diagnostic parameters (echocardiography and magnetic resonance imaging). In the second, we added modelled parameters (pressure fields). For the two cases with borderline indications for intervention, the second dataset also included pressure fields after virtual stenting simulations. All parameters were computed by modelling methods that were previously validated. In an online-administered, invitation-only survey, we randomized 178 paediatric cardiologists to view either conventional (control) or add-on modelling (experimental) datasets. Primary endpoint was the proportion of participants recommending different therapeutic options: (1) surgery or catheter lab (collectively, "intervention") or (2) no intervention (follow-up with or without medication). Availability of data from computational predictive modelling influenced therapeutic decision making in two of three cases. There was a statistically significant association between group assignment and the recommendation of an intervention for one borderline case and one non-borderline case: 94.3% vs. 72.2% (RR: 1.31, 95% CI: 1.14-1.50, p = 0.00) and 18.8% vs. 5.1% (RR: 3.09, 95% CI: 1.17-8.18, p = 0.01) of participants in the experimental and control groups respectively recommended an intervention. For the remaining case, there was no difference between the experimental and control group and the majority of participants recommended intervention. In sub-group analyses, findings were not affected by the experience level of participating cardiologists. Despite existing clinical guidelines, the therapy recommendations of the participating physicians were heterogeneous. Validated patient-specific computational modelling has the potential to influence treatment decisions. Future studies in broader areas are needed to evaluate whether differences in decisions result in improved outcomes (Trial Registration: NCT02700737).
Collapse
Affiliation(s)
- Huseyin Naci
- 1LSE Health, Department of Health Policy, London School of Economics and Political Science, London, UK
| | - Maximilian Salcher-Konrad
- 1LSE Health, Department of Health Policy, London School of Economics and Political Science, London, UK
| | - Alistair Mcguire
- 1LSE Health, Department of Health Policy, London School of Economics and Political Science, London, UK
| | - Felix Berger
- 2German Heart Institute Berlin (DHZB), Berlin, Germany.,3Charité - Universitätsmedizin Berlin, Pediatric Cardiology, Berlin, Germany.,4DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Titus Kuehne
- 2German Heart Institute Berlin (DHZB), Berlin, Germany.,4DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany.,Institute for Computational and Imaging Science in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Leonid Goubergrits
- Institute for Computational and Imaging Science in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Vivek Muthurangu
- 6Great Ormond Street Hospital, University College London, London, UK
| | - Ben Wilson
- 7Department of Sociology, Stockholm University, Stockholm, Sweden.,8Department of Methodology, London School of Economics and Political Science, London, UK
| | - Marcus Kelm
- 2German Heart Institute Berlin (DHZB), Berlin, Germany.,3Charité - Universitätsmedizin Berlin, Pediatric Cardiology, Berlin, Germany.,Institute for Computational and Imaging Science in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
23
|
Lan H, Updegrove A, Wilson NM, Maher GD, Shadden SC, Marsden AL. A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package. J Biomech Eng 2019; 140:2666622. [PMID: 29238826 DOI: 10.1115/1.4038751] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Indexed: 11/08/2022]
Abstract
Patient-specific simulation plays an important role in cardiovascular disease research, diagnosis, surgical planning and medical device design, as well as education in cardiovascular biomechanics. simvascular is an open-source software package encompassing an entire cardiovascular modeling and simulation pipeline from image segmentation, three-dimensional (3D) solid modeling, and mesh generation, to patient-specific simulation and analysis. SimVascular is widely used for cardiovascular basic science and clinical research as well as education, following increased adoption by users and development of a GATEWAY web portal to facilitate educational access. Initial efforts of the project focused on replacing commercial packages with open-source alternatives and adding increased functionality for multiscale modeling, fluid-structure interaction (FSI), and solid modeling operations. In this paper, we introduce a major SimVascular (SV) release that includes a new graphical user interface (GUI) designed to improve user experience. Additional improvements include enhanced data/project management, interactive tools to facilitate user interaction, new boundary condition (BC) functionality, plug-in mechanism to increase modularity, a new 3D segmentation tool, and new computer-aided design (CAD)-based solid modeling capabilities. Here, we focus on major changes to the software platform and outline features added in this new release. We also briefly describe our recent experiences using SimVascular in the classroom for bioengineering education.
Collapse
Affiliation(s)
- Hongzhi Lan
- Department of Pediatrics, Stanford University, Stanford, CA 94305
| | - Adam Updegrove
- Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA 94720
| | - Nathan M Wilson
- Open Source Medical Software Corporation, Santa Monica, CA 90403
| | | | - Shawn C Shadden
- Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA 94720
| | - Alison L Marsden
- Department of Pediatrics, Stanford University, , Stanford, CA 94305-5428.,ICME, Stanford University, Stanford, CA 94305.,Department of Bioengineering, Stanford University, Stanford, CA 94305 e-mail:
| |
Collapse
|
24
|
Trusty PM, Wei Z, Sales M, Kanter KR, Fogel MA, Yoganathan AP, Slesnick TC. Y-graft modification to the Fontan procedure: Increasingly balanced flow over time. J Thorac Cardiovasc Surg 2019; 159:652-661. [PMID: 31399233 DOI: 10.1016/j.jtcvs.2019.06.063] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 06/03/2019] [Accepted: 06/13/2019] [Indexed: 12/28/2022]
Abstract
OBJECTIVE The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. METHODS Ten Fontan patients with commercially available Y-graft connections and serial postoperative cardiac magnetic resonance data were included in this study. Patient-specific computational fluid dynamics simulations were used to estimate HFD and energy losses. Y-graft performance was compared with 3 extracardiac conduit Fontan groups (n = 10 for each) whose follow-up times straddle the Y-graft time points. RESULTS Y-graft HFD became significantly more balanced over time (deviation from 50% decreased from 18% ± 14% to 8% ± 8%; P = .015). Total cavopulmonary connection resistance did not significantly change. Y-grafts at 3-year follow-up showed more balanced HFD than the extracardiac conduit groups at both the earlier and later follow-up times. Total cavopulmonary connection resistance was not significantly different between any Y-graft or extracardiac conduit group. CONCLUSIONS Y-grafts showed significantly more balanced HFD over a 3-year follow-up without an increase in total cavopulmonary connection resistance, and therefore may be a valuable option for Fontan completion. Additional follow-up data at longer follow-up times are still needed to thoroughly characterize the potential advantages of Y-graft use.
Collapse
Affiliation(s)
- Phillip M Trusty
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Ga
| | - Zhenglun Wei
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Ga
| | - Megan Sales
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Ga
| | - Kirk R Kanter
- Division of Cardiothoracic Surgery, Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, Ga
| | - Mark A Fogel
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Ga.
| | - Timothy C Slesnick
- Division of Cardiology, Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, Ga
| |
Collapse
|
25
|
Wei ZA, Huddleston C, Trusty PM, Singh-Gryzbon S, Fogel MA, Veneziani A, Yoganathan AP. Analysis of Inlet Velocity Profiles in Numerical Assessment of Fontan Hemodynamics. Ann Biomed Eng 2019; 47:2258-2270. [PMID: 31236791 DOI: 10.1007/s10439-019-02307-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Accepted: 06/08/2019] [Indexed: 12/16/2022]
Abstract
Computational fluid dynamic (CFD) simulations are widely utilized to assess Fontan hemodynamics that are related to long-term complications. No previous studies have systemically investigated the effects of using different inlet velocity profiles in Fontan simulations. This study implements real, patient-specific velocity profiles for numerical assessment of Fontan hemodynamics using CFD simulations. Four additional, artificial velocity profiles were used for comparison: (1) flat, (2) parabolic, (3) Womersley, and (4) parabolic with inlet extensions [to develop flow before entering the total cavopulmonary connection (TCPC)]. The differences arising from the five velocity profiles, as well as discrepancies between the real and each of the artificial velocity profiles, were quantified by examining clinically important metrics in TCPC hemodynamics: power loss (PL), viscous dissipation rate (VDR), hepatic flow distribution, and regions of low wall shear stress. Statistically significant differences were observed in PL and VDR between simulations using real and flat velocity profiles, but differences between those using real velocity profiles and the other three artificial profiles did not reach statistical significance. These conclusions suggest that the artificial velocity profiles (2)-(4) are acceptable surrogates for real velocity profiles in Fontan simulations, but parabolic profiles are recommended because of their low computational demands and prevalent applicability.
Collapse
Affiliation(s)
- Zhenglun Alan Wei
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Connor Huddleston
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, USA
| | - Phillip M Trusty
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Shelly Singh-Gryzbon
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Mark A Fogel
- Department of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Alessandro Veneziani
- Department of Mathematics, Department of Computer Science, Emory University, Atlanta, GA, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA.
| |
Collapse
|
26
|
Current Challenges and Emergent Technologies for Manufacturing Artificial Right Ventricle to Pulmonary Artery (RV-PA) Cardiac Conduits. Cardiovasc Eng Technol 2019; 10:205-215. [DOI: 10.1007/s13239-019-00406-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 02/05/2019] [Indexed: 01/12/2023]
|
27
|
Oakes JM, Mummy D, Poorbahrami K, Zha W, Fain SB. Patient-Specific Computational Simulations of Hyperpolarized 3He MRI Ventilation Defects in Healthy and Asthmatic Subjects. IEEE Trans Biomed Eng 2018; 66:1318-1327. [PMID: 30281426 DOI: 10.1109/tbme.2018.2872845] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Combined, medical imaging data and respiratory computer simulations may facilitate novel insight into pulmonary disease phenotypes, including the structure/function relationships within the airways. This integration may ultimately enable improved classification and treatment of asthma. Severe asthma (15% of asthmatics) is particularly challenging to treat, as these patients do not respond well to inhaled therapeutics. METHODS This study combines medical image data with patient-specific computational models to predict gas distributions and airway mechanics in healthy and asthmatic subjects. We achieve this by integrating segmental volume defect percent (SVDP), measured from hyperpolarized 3He MRI and CT images, to create models of patient-specific gas flow within the conducting airways. Predicted and measured SVDP distributions are achieved when the prescribed resistances are increased systematically. RESULTS Because of differences in airway morphology and regional function, airway resistances and flow structures varied between the asthmatic subjects. Specifically, while mean SVDP was similar between the severe asthmatics (4.30±5.22 versus 3.54±5.98%), one subject exhibited abnormal flow structures, high near wall flow gradients, and enhanced conducting airway resistances (17.3E-3versus 1.1E-3 cmH2O-s/mL) in comparison to the other severe asthmatic subject. CONCLUSION By coupling medical imaging data with computer simulations, we provide detailed insight into pathological flow characteristics and airway mechanics in asthmatics, beyond what could be inferred independently.
Collapse
|
28
|
Trusty PM, Slesnick TC, Wei ZA, Rossignac J, Kanter KR, Fogel MA, Yoganathan AP. Fontan Surgical Planning: Previous Accomplishments, Current Challenges, and Future Directions. J Cardiovasc Transl Res 2018; 11:133-144. [PMID: 29340873 PMCID: PMC5910220 DOI: 10.1007/s12265-018-9786-0] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 01/05/2018] [Indexed: 11/29/2022]
Abstract
The ultimate goal of Fontan surgical planning is to provide additional insights into the clinical decision-making process. In its current state, surgical planning offers an accurate hemodynamic assessment of the pre-operative condition, provides anatomical constraints for potential surgical options, and produces decent post-operative predictions if boundary conditions are similar enough between the pre-operative and post-operative states. Moving forward, validation with post-operative data is a necessary step in order to assess the accuracy of surgical planning and determine which methodological improvements are needed. Future efforts to automate the surgical planning process will reduce the individual expertise needed and encourage use in the clinic by clinicians. As post-operative physiologic predictions improve, Fontan surgical planning will become an more effective tool to accurately model patient-specific hemodynamics.
Collapse
Affiliation(s)
- Phillip M Trusty
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Timothy C Slesnick
- Department of Pediatrics, Division of Cardiology, Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA, USA
| | - Zhenglun Alan Wei
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- School of Life Science, Fudan University, Shanghai, China
| | - Jarek Rossignac
- School of Interactive Computing, Georgia Institute of Technology, Atlanta, GA, USA
| | - Kirk R Kanter
- Division of Cardiothoracic Surgery, Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA, USA
| | - Mark A Fogel
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.
| |
Collapse
|
29
|
Cheng AL, Pahlevan NM, Rinderknecht DG, Wood JC, Gharib M. Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation. EUROPEAN JOURNAL OF MECHANICS. B, FLUIDS 2018; 68:184-192. [PMID: 29736127 PMCID: PMC5935448 DOI: 10.1016/j.euromechflu.2017.12.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The Fontan procedure for univentricular heart defects creates a unique circulation where all pulmonary blood flow is passively supplied directly from systemic veins. Computational simulations, aimed at optimizing the surgery, have assumed blood to be a Newtonian fluid without evaluating the potential error introduced by this assumption. We compared flow behavior between a non-Newtonian blood analog (0.04% xanthan gum) and a control Newtonian fluid (45% glycerol) in a simplified model of the Fontan circulation. Particle image velocimetry was used to examine flow behavior at two different cardiac outputs and two caval blood flow distributions. Pressure and flow rates were measured at each inlet and outlet. Velocity, shear strain, and shear stress maps were derived from velocity data. Power loss was calculated from pressure, flow, and velocity data. Power loss was increased in all test conditions with xanthan gum vs. glycerol (mean 10±2.9% vs. 5.6±1.3%, p=0.032). Pulmonary blood flow distribution differed in all conditions, more so at low cardiac output. Caval blood flow mixing patterns and shear stress were also qualitatively different between the solutions in all conditions. We conclude that assuming blood to be a Newtonian fluid introduces considerable error into simulations of the Fontan circulation, where low-shear flow predominates.
Collapse
Affiliation(s)
- Andrew L. Cheng
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Niema M. Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA
- Huntington Medical Research Institutes, Pasadena, CA, USA
| | - Derek G. Rinderknecht
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
| | - John C. Wood
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Morteza Gharib
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
- Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
30
|
Siallagan D, Loke YH, Olivieri L, Opfermann J, Ong CS, de Zélicourt D, Petrou A, Daners MS, Kurtcuoglu V, Meboldt M, Nelson K, Vricella L, Johnson J, Hibino N, Krieger A. Virtual surgical planning, flow simulation, and 3-dimensional electrospinning of patient-specific grafts to optimize Fontan hemodynamics. J Thorac Cardiovasc Surg 2017; 155:1734-1742. [PMID: 29361303 DOI: 10.1016/j.jtcvs.2017.11.068] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 11/09/2017] [Accepted: 11/27/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Despite advances in the Fontan procedure, there is an unmet clinical need for patient-specific graft designs that are optimized for variations in patient anatomy. The objective of this study is to design and produce patient-specific Fontan geometries, with the goal of improving hepatic flow distribution (HFD) and reducing power loss (Ploss), and manufacturing these designs by electrospinning. METHODS Cardiac magnetic resonance imaging data from patients who previously underwent a Fontan procedure (n = 2) was used to create 3-dimensional models of their native Fontan geometry using standard image segmentation and geometry reconstruction software. For each patient, alternative designs were explored in silico, including tube-shaped and bifurcated conduits, and their performance in terms of Ploss and HFD probed by computational fluid dynamic (CFD) simulations. The best-performing options were then fabricated using electrospinning. RESULTS CFD simulations showed that the bifurcated conduit improved HFD between the left and right pulmonary arteries, whereas both types of conduits reduced Ploss. In vitro testing with a flow-loop chamber supported the CFD results. The proposed designs were then successfully electrospun into tissue-engineered vascular grafts. CONCLUSIONS Our unique virtual cardiac surgery approach has the potential to improve the quality of surgery by manufacturing patient-specific designs before surgery, that are also optimized with balanced HFD and minimal Ploss, based on refinement of commercially available options for image segmentation, computer-aided design, and flow simulations.
Collapse
Affiliation(s)
- Dominik Siallagan
- Sheikh Zayed Institute for Surgical Innovation, Children's National Medical Center, Washington, DC; Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Yue-Hin Loke
- Division of Cardiology, Children's National Health System, Washington, DC
| | - Laura Olivieri
- Sheikh Zayed Institute for Surgical Innovation, Children's National Medical Center, Washington, DC; Division of Cardiology, Children's National Health System, Washington, DC
| | - Justin Opfermann
- Sheikh Zayed Institute for Surgical Innovation, Children's National Medical Center, Washington, DC
| | - Chin Siang Ong
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | - Diane de Zélicourt
- The Interface Group, Institute of Physiology, University of Zürich, Zurich, Switzerland; Swiss National Centre of Competence in Research, Kidney Control of Homeostasis, Zurich, Switzerland
| | - Anastasios Petrou
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Vartan Kurtcuoglu
- The Interface Group, Institute of Physiology, University of Zürich, Zurich, Switzerland; Swiss National Centre of Competence in Research, Kidney Control of Homeostasis, Zurich, Switzerland
| | - Mirko Meboldt
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | | | - Luca Vricella
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md
| | | | - Narutoshi Hibino
- Division of Cardiac Surgery, Johns Hopkins Hospital, Baltimore, Md.
| | - Axel Krieger
- Sheikh Zayed Institute for Surgical Innovation, Children's National Medical Center, Washington, DC; Department of Mechanical Engineering, University of Maryland, College Park, Md
| |
Collapse
|
31
|
Yang W, Hanley FL, Chan FP, Marsden AL, Vignon-Clementel IE, Feinstein JA. Computational simulation of postoperative pulmonary flow distribution in Alagille patients with peripheral pulmonary artery stenosis. CONGENIT HEART DIS 2017; 13:241-250. [PMID: 29194961 DOI: 10.1111/chd.12556] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2017] [Revised: 10/24/2017] [Accepted: 10/28/2017] [Indexed: 11/28/2022]
Abstract
BACKGROUND Up to 90% of individuals with Alagille syndrome have congenital heart diseases. Peripheral pulmonary artery stenosis (PPS), resulting in right ventricular hypertension and pulmonary flow disparity, is one of the most common abnormalities, yet the hemodynamic effects are ill-defined, and optimal patient management and treatment strategies are not well established. The purpose of this pilot study is to use recently refined computational simulation in the setting of multiple surgical strategies, to examine the influence of pulmonary artery reconstruction on hemodynamics in this population. MATERIALS AND METHODS Based on computed tomography angiography and cardiac catheterization data, preoperative pulmonary artery models were constructed for 4 patients with Alagille syndrome with PPS (all male, age range: 0.6-2.9 years), and flow simulations with deformable walls were performed. Surgeon directed virtual surgery, mimicking the surgical procedure, was then performed to derive postoperative models. Postoperative simulation-derived hemodynamics and blood flow distribution were then compared with the clinical results. RESULTS Simulations confirmed substantial resistance, resulting from preoperative severe ostial stenoses, and the use of newly developed adaptive outflow boundary conditions led to excellent agreement with in vivo measurements. Relief of PPS decreased pulmonary artery pressures and improved pulmonary flow distribution both in vivo and in silico with good correlation. CONCLUSIONS Using adaptive outflow boundary conditions, computational simulations can estimate postoperative overall pulmonary flow distribution in patients with Alagille syndrome after pulmonary artery reconstruction. Obstruction relief along with pulmonary artery vasodilation determines postoperative pulmonary flow distribution and newer methods can incorporate these physiologic changes. Evolving blood flow simulations may be useful in surgical or transcatheter planning and in understanding the complex interplay among various obstructions in patients with peripheral pulmonary stenosis.
Collapse
Affiliation(s)
- Weiguang Yang
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, California, USA
| | - Frank L Hanley
- Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, California, USA
| | - Frandics P Chan
- Department of Radiology, Stanford University School of Medicine, Stanford, California, USA
| | - Alison L Marsden
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, California, USA.,Department of BioEngineering, Stanford University School of Medicine, Stanford, California, USA
| | - Irene E Vignon-Clementel
- INRIA and Sorbonne Universités UPMC, Univ. Paris 6, Laboratoire Jacques-Louis Lions, Paris, France
| | - Jeffrey A Feinstein
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, California, USA.,Department of BioEngineering, Stanford University School of Medicine, Stanford, California, USA
| |
Collapse
|
32
|
Impact of the location of the fenestration on Fontan circulation haemodynamics: a three-dimensional, computational model study. Cardiol Young 2017; 27:1289-1294. [PMID: 28376950 DOI: 10.1017/s1047951117000099] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVES There is no consensus or theoretical explanation regarding the optimal location for the fenestration during the Fontan operation. We investigated the impact of the location of the fenestration on Fontan haemodynamics using a three-dimensional Fontan model in various physiological conditions. METHODS A three-dimensional Fontan model was constructed on the basis of CT images, and a 4-mm-diameter fenestration was located between the extracardiac Fontan conduit and the right atrium at three positions: superior, middle, and inferior part of the conduit. Haemodynamics in the Fontan route were analysed using a three-dimensional computational fluid dynamic model in realistic physiological conditions, which were predicted using a lumped parameter model of the cardiovascular system. The respiratory effect of the caval flow was taken into account. The flow rate through the fenestration, the effect of lowering the central venous pressure, and wall shear stress in the Fontan circuit were evaluated under central venous pressures of 10, 15, and 20 mmHg. The pulse power index and pulsatile energy loss index were calculated as energy loss indices. RESULTS Under all central venous pressures, the middle-part fenestration demonstrated the most significant effect on enhancing the flow rate through the fenestration while lowering the central venous pressure. The middle-part fenestration produced the highest time-averaged wall shear stress, pressure pulse index, and pulsatile energy loss index. CONCLUSIONS Despite slightly elevated energy loss, the middle-part fenestration most significantly increased cardiac output and lowered central venous pressure under respiration in the Fontan circulation.
Collapse
|
33
|
Lee JW, Park JJ, Goo HW, Ko JK. Fontan Revision with Y-Graft in a Patient with Unilateral Pulmonary Arteriovenous Malformation. THE KOREAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2017; 50:207-210. [PMID: 28593158 PMCID: PMC5460969 DOI: 10.5090/kjtcs.2017.50.3.207] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 10/27/2016] [Accepted: 10/28/2016] [Indexed: 11/18/2022]
Abstract
The extracardiac conduit Fontan procedure is the last surgical step in the treatment of patients with a functional single ventricle. An acquired pulmonary arteriovenous malformation may appear perioperatively or postoperatively due to an uneven hepatic flow distribution. Here we report a case of a bifurcated Y-graft Fontan operation in a 15-year-old male patient with a unilateral pulmonary arteriovenous malformation after an extracardiac conduit Fontan operation.
Collapse
Affiliation(s)
- Jeong-Woo Lee
- Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine
| | - Jeong-Jun Park
- Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine
| | - Hyun Woo Goo
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Jae Kon Ko
- Department of Pediatric Cardiology, Asan Medical Center, University of Ulsan College of Medicine
| |
Collapse
|
34
|
Hariharan P, D’Souza GA, Horner M, Morrison TM, Malinauskas RA, Myers MR. Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations. PLoS One 2017; 12:e0178749. [PMID: 28594889 PMCID: PMC5464577 DOI: 10.1371/journal.pone.0178749] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 05/18/2017] [Indexed: 12/14/2022] Open
Abstract
A "credible" computational fluid dynamics (CFD) model has the potential to provide a meaningful evaluation of safety in medical devices. One major challenge in establishing "model credibility" is to determine the required degree of similarity between the model and experimental results for the model to be considered sufficiently validated. This study proposes a "threshold-based" validation approach that provides a well-defined acceptance criteria, which is a function of how close the simulation and experimental results are to the safety threshold, for establishing the model validity. The validation criteria developed following the threshold approach is not only a function of Comparison Error, E (which is the difference between experiments and simulations) but also takes in to account the risk to patient safety because of E. The method is applicable for scenarios in which a safety threshold can be clearly defined (e.g., the viscous shear-stress threshold for hemolysis in blood contacting devices). The applicability of the new validation approach was tested on the FDA nozzle geometry. The context of use (COU) was to evaluate if the instantaneous viscous shear stress in the nozzle geometry at Reynolds numbers (Re) of 3500 and 6500 was below the commonly accepted threshold for hemolysis. The CFD results ("S") of velocity and viscous shear stress were compared with inter-laboratory experimental measurements ("D"). The uncertainties in the CFD and experimental results due to input parameter uncertainties were quantified following the ASME V&V 20 standard. The CFD models for both Re = 3500 and 6500 could not be sufficiently validated by performing a direct comparison between CFD and experimental results using the Student's t-test. However, following the threshold-based approach, a Student's t-test comparing |S-D| and |Threshold-S| showed that relative to the threshold, the CFD and experimental datasets for Re = 3500 were statistically similar and the model could be considered sufficiently validated for the COU. However, for Re = 6500, at certain locations where the shear stress is close the hemolysis threshold, the CFD model could not be considered sufficiently validated for the COU. Our analysis showed that the model could be sufficiently validated either by reducing the uncertainties in experiments, simulations, and the threshold or by increasing the sample size for the experiments and simulations. The threshold approach can be applied to all types of computational models and provides an objective way of determining model credibility and for evaluating medical devices.
Collapse
Affiliation(s)
- Prasanna Hariharan
- US Food and Drug Administration, Silver Spring, Maryland, United States of America
- * E-mail:
| | - Gavin A. D’Souza
- US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Marc Horner
- ANSYS, Inc., Evanston, Illinois, United States of America
| | - Tina M. Morrison
- US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | | | - Matthew R. Myers
- US Food and Drug Administration, Silver Spring, Maryland, United States of America
| |
Collapse
|
35
|
Local Hemodynamic Differences Between Commercially Available Y-Grafts and Traditional Fontan Baffles Under Simulated Exercise Conditions: Implications for Exercise Tolerance. Cardiovasc Eng Technol 2017; 8:390-399. [DOI: 10.1007/s13239-017-0310-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 05/23/2017] [Indexed: 10/19/2022]
|
36
|
Updegrove A, Wilson NM, Merkow J, Lan H, Marsden AL, Shadden SC. SimVascular: An Open Source Pipeline for Cardiovascular Simulation. Ann Biomed Eng 2016; 45:525-541. [PMID: 27933407 DOI: 10.1007/s10439-016-1762-8] [Citation(s) in RCA: 258] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Accepted: 11/10/2016] [Indexed: 12/19/2022]
Abstract
Patient-specific cardiovascular simulation has become a paradigm in cardiovascular research and is emerging as a powerful tool in basic, translational and clinical research. In this paper we discuss the recent development of a fully open-source SimVascular software package, which provides a complete pipeline from medical image data segmentation to patient-specific blood flow simulation and analysis. This package serves as a research tool for cardiovascular modeling and simulation, and has contributed to numerous advances in personalized medicine, surgical planning and medical device design. The SimVascular software has recently been refactored and expanded to enhance functionality, usability, efficiency and accuracy of image-based patient-specific modeling tools. Moreover, SimVascular previously required several licensed components that hindered new user adoption and code management and our recent developments have replaced these commercial components to create a fully open source pipeline. These developments foster advances in cardiovascular modeling research, increased collaboration, standardization of methods, and a growing developer community.
Collapse
Affiliation(s)
- Adam Updegrove
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Nathan M Wilson
- Open Source Medical Software Corporation, Santa Monica, CA, USA
| | - Jameson Merkow
- Department of Electrical and Computer Engineering, University of California, San Diego, CA, USA
| | - Hongzhi Lan
- Department of Bioengineering, Stanford University, Palo Alto, CA, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Palo Alto, CA, USA.,Department of Pediatrics, Stanford University, Palo Alto, CA, USA
| | - Shawn C Shadden
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA. .,University of California, Berkeley, CA, 94720-1740, USA.
| |
Collapse
|
37
|
Biglino G, Capelli C, Bruse J, Bosi GM, Taylor AM, Schievano S. Computational modelling for congenital heart disease: how far are we from clinical translation? Heart 2016; 103:98-103. [PMID: 27798056 PMCID: PMC5284484 DOI: 10.1136/heartjnl-2016-310423] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 09/26/2016] [Accepted: 09/29/2016] [Indexed: 12/17/2022] Open
Abstract
Computational models of congenital heart disease (CHD) have become increasingly sophisticated over the last 20 years. They can provide an insight into complex flow phenomena, allow for testing devices into patient-specific anatomies (pre-CHD or post-CHD repair) and generate predictive data. This has been applied to different CHD scenarios, including patients with single ventricle, tetralogy of Fallot, aortic coarctation and transposition of the great arteries. Patient-specific simulations have been shown to be informative for preprocedural planning in complex cases, allowing for virtual stent deployment. Novel techniques such as statistical shape modelling can further aid in the morphological assessment of CHD, risk stratification of patients and possible identification of new ‘shape biomarkers’. Cardiovascular statistical shape models can provide valuable insights into phenomena such as ventricular growth in tetralogy of Fallot, or morphological aortic arch differences in repaired coarctation. In a constant move towards more realistic simulations, models can also account for multiscale phenomena (eg, thrombus formation) and importantly include measures of uncertainty (ie, CIs around simulation results). While their potential to aid understanding of CHD, surgical/procedural decision-making and personalisation of treatments is undeniable, important elements are still lacking prior to clinical translation of computational models in the field of CHD, that is, large validation studies, cost-effectiveness evaluation and establishing possible improvements in patient outcomes.
Collapse
Affiliation(s)
- Giovanni Biglino
- Bristol Heart Institute, School of Clinical Sciences, University of Bristol, Bristol, UK.,Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | - Claudio Capelli
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,Institute of Cardiovascular Science, University College London, London, UK
| | - Jan Bruse
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,Institute of Cardiovascular Science, University College London, London, UK
| | - Giorgia M Bosi
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,Institute of Cardiovascular Science, University College London, London, UK
| | - Andrew M Taylor
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,Institute of Cardiovascular Science, University College London, London, UK
| | - Silvia Schievano
- Cardiorespiratory Unit, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,Institute of Cardiovascular Science, University College London, London, UK
| |
Collapse
|
38
|
Ramachandra AB, Kahn AM, Marsden AL. Patient-Specific Simulations Reveal Significant Differences in Mechanical Stimuli in Venous and Arterial Coronary Grafts. J Cardiovasc Transl Res 2016; 9:279-90. [PMID: 27447176 DOI: 10.1007/s12265-016-9706-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 07/04/2016] [Indexed: 01/17/2023]
Abstract
Mechanical stimuli are key to understanding disease progression and clinically observed differences in failure rates between arterial and venous grafts following coronary artery bypass graft surgery. We quantify biologically relevant mechanical stimuli, not available from standard imaging, in patient-specific simulations incorporating non-invasive clinical data. We couple CFD with closed-loop circulatory physiology models to quantify biologically relevant indices, including wall shear, oscillatory shear, and wall strain. We account for vessel-specific material properties in simulating vessel wall deformation. Wall shear was significantly lower (p = 0.014*) and atheroprone area significantly higher (p = 0.040*) in venous compared to arterial grafts. Wall strain in venous grafts was significantly lower (p = 0.003*) than in arterial grafts while no significant difference was observed in oscillatory shear index. Simulations demonstrate significant differences in mechanical stimuli acting on venous vs. arterial grafts, in line with clinically observed graft failure rates, offering a promising avenue for stratifying patients at risk for graft failure.
Collapse
Affiliation(s)
- Abhay B Ramachandra
- Department of Mechanical and Aerospace Engineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA 92093, USA.,Departments of Pediatrics and Bioengineering, Institute for Computational and Mathematical Engineering, Stanford University, Stanford, CA, 94305, USA
| | - Andrew M Kahn
- Department of Medicine, University of California San Diego, 9500 Gilman Drive, La Jolla, CA 92093, USA
| | - Alison L Marsden
- Departments of Pediatrics and Bioengineering, Institute for Computational and Mathematical Engineering, Stanford University, Clark Center E100B 318 Campus Drive, Stanford,, CA, 94305-5428, USA.
| |
Collapse
|
39
|
|
40
|
A pulsatile hemodynamic evaluation of the commercially available bifurcated Y-graft Fontan modification and comparison with the lateral tunnel and extracardiac conduits. J Thorac Cardiovasc Surg 2016; 151:1529-36. [DOI: 10.1016/j.jtcvs.2016.03.019] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 03/01/2016] [Accepted: 03/05/2016] [Indexed: 11/22/2022]
|
41
|
Adaptive outflow boundary conditions improve post-operative predictions after repair of peripheral pulmonary artery stenosis. Biomech Model Mechanobiol 2016; 15:1345-53. [PMID: 26843118 DOI: 10.1007/s10237-016-0766-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Accepted: 01/19/2016] [Indexed: 12/21/2022]
Abstract
Peripheral pulmonary artery stenosis (PPS) is a congenital abnormality resulting in pulmonary blood flow disparity and right ventricular hypertension. Despite recent advance in catheter-based interventions, surgical reconstruction is still preferred to treat complex PPS. However optimal surgical strategies remain unclear. It would be of great benefit to be able to predict post-operative hemodynamics to assist with surgical planning toward optimizing outcomes. While image-based computational fluid dynamics has been used in cardiovascular surgical planning, most studies have focused on the impact of local geometric changes on hemodynamic performance. Previous experimental studies suggest morphological changes in the pulmonary arteries not only alter local hemodynamics but also lead to distal pulmonary adaptation. In this proof of concept study, a constant shear stress hypothesis and structured pulmonary trees are used to derive adaptive outflow boundary conditions for post-operative simulations. Patient-specific simulations showed the adaptive outflow boundary conditions by the constant shear stress model to provide better predictions of pulmonary flow distribution than the conventional strategy of maintaining outflow boundary conditions. On average, the relative difference, when compared to the gold standard clinical test, in blood flow distribution to the right lung is reduced from 20 to 4 %. This suggests adaptive outflow boundary conditions should be incorporated into post-operative modeling in patients with complex PPS.
Collapse
|
42
|
Abstract
PURPOSE OF REVIEW Recent methodological advances in computational simulations are enabling increasingly realistic simulations of hemodynamics and physiology, driving increased clinical utility. We review recent developments in the use of computational simulations in pediatric and congenital heart disease, describe the clinical impact in modeling in single-ventricle patients, and provide an overview of emerging areas. RECENT FINDINGS Multiscale modeling combining patient-specific hemodynamics with reduced order (i.e., mathematically and computationally simplified) circulatory models has become the de-facto standard for modeling local hemodynamics and 'global' circulatory physiology. We review recent advances that have enabled faster solutions, discuss new methods (e.g., fluid structure interaction and uncertainty quantification), which lend realism both computationally and clinically to results, highlight novel computationally derived surgical methods for single-ventricle patients, and discuss areas in which modeling has begun to exert its influence including Kawasaki disease, fetal circulation, tetralogy of Fallot (and pulmonary tree), and circulatory support. SUMMARY Computational modeling is emerging as a crucial tool for clinical decision-making and evaluation of novel surgical methods and interventions in pediatric cardiology and beyond. Continued development of modeling methods, with an eye towards clinical needs, will enable clinical adoption in a wide range of pediatric and congenital heart diseases.
Collapse
|
43
|
de Zélicourt DA, Kurtcuoglu V. Patient-Specific Surgical Planning, Where Do We Stand? The Example of the Fontan Procedure. Ann Biomed Eng 2015; 44:174-86. [PMID: 26183962 DOI: 10.1007/s10439-015-1381-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Accepted: 07/02/2015] [Indexed: 11/30/2022]
Abstract
The Fontan surgery for single ventricle heart defects is a typical example of a clinical intervention in which patient-specific computational modeling can improve patient outcome: with the functional heterogeneity of the presenting patients, which precludes generic solutions, and the clear influence of the surgically-created Fontan connection on hemodynamics, it is acknowledged that individualized computational optimization of the post-operative hemodynamics can be of clinical value. A large body of literature has thus emerged seeking to provide clinically relevant answers and innovative solutions, with an increasing emphasis on patient-specific approaches. In this review we discuss the benefits and challenges of patient-specific simulations for the Fontan surgery, reviewing state of the art solutions and avenues for future development. We first discuss the clinical impact of patient-specific simulations, notably how they have contributed to our understanding of the link between Fontan hemodynamics and patient outcome. This is followed by a survey of methodologies for capturing patient-specific hemodynamics, with an emphasis on the challenges of defining patient-specific boundary conditions and their extension for prediction of post-operative outcome. We conclude with insights into potential future directions, noting that one of the most pressing issues might be the validation of the predictive capabilities of the developed framework.
Collapse
Affiliation(s)
- Diane A de Zélicourt
- The Interface Group, Institute of Physiology, University of Zurich, Winterthurerstrasse 190, 8057, Zurich, Switzerland.
| | - Vartan Kurtcuoglu
- The Interface Group, Institute of Physiology, University of Zurich, Winterthurerstrasse 190, 8057, Zurich, Switzerland
- Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland
- National Center of Competence 'Kidney.CH', Zurich, Switzerland
| |
Collapse
|
44
|
Martin MH, Feinstein JA, Chan FP, Marsden AL, Yang W, Reddy VM. Technical feasibility and intermediate outcomes of using a handcrafted, area-preserving, bifurcated Y-graft modification of the Fontan procedure. J Thorac Cardiovasc Surg 2015; 149:239-45.e1. [DOI: 10.1016/j.jtcvs.2014.08.058] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 08/16/2014] [Accepted: 08/23/2014] [Indexed: 11/16/2022]
|
45
|
Tang E, Yoganathan AP. Optimizing hepatic flow distribution with the Fontan Y-graft: Lessons from computational simulations. J Thorac Cardiovasc Surg 2015; 149:255-6. [DOI: 10.1016/j.jtcvs.2014.09.094] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2014] [Accepted: 09/25/2014] [Indexed: 10/24/2022]
|
46
|
Davies RR, Pizarro C. Decision-Making for Surgery in the Management of Patients with Univentricular Heart. Front Pediatr 2015; 3:61. [PMID: 26284226 PMCID: PMC4515559 DOI: 10.3389/fped.2015.00061] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 06/21/2015] [Indexed: 12/24/2022] Open
Abstract
A series of technical refinements over the past 30 years, in combination with advances in perioperative management, have resulted in dramatic improvements in the survival of patients with univentricular heart. While the goal of single-ventricle palliation remains unchanged - normalization of the pressure and volume loads on the systemic ventricle, the strategies to achieve that goal have become more diverse. Optimal palliation relies on a thorough understanding of the changing physiology over the first years of life and the risks and consequences of each palliative strategy. This review describes how to optimize surgical decision-making in univentricular patients based on a current understanding of anatomy, physiology, and surgical palliation.
Collapse
Affiliation(s)
- Ryan Robert Davies
- Nemours Cardiac Center, A. I. duPont Hospital for Children , Wilmington, DE , USA ; Thomas Jefferson University , Philadelphia, PA , USA
| | - Christian Pizarro
- Nemours Cardiac Center, A. I. duPont Hospital for Children , Wilmington, DE , USA ; Thomas Jefferson University , Philadelphia, PA , USA
| |
Collapse
|