1
|
Vojnov L, Carmona S, Zeh C, Markby J, Boeras D, Prescott MR, Mayne ALH, Sawadogo S, Adje-Toure C, Zhang G, Perez Gonzalez M, Stevens WS, Doherty M, Yang C, Alexander H, Peter TF, Nkengasong J. The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis. PLoS Med 2022; 19:e1004076. [PMID: 35994520 PMCID: PMC9447868 DOI: 10.1371/journal.pmed.1004076] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 09/06/2022] [Accepted: 07/13/2022] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Accurate routine HIV viral load testing is essential for assessing the efficacy of antiretroviral treatment (ART) regimens and the emergence of drug resistance. While the use of plasma specimens is the standard for viral load testing, its use is restricted by the limited ambient temperature stability of viral load biomarkers in whole blood and plasma during storage and transportation and the limited cold chain available between many health care facilities in resource-limited settings. Alternative specimen types and technologies, such as dried blood spots, may address these issues and increase access to viral load testing; however, their technical performance is unclear. To address this, we conducted a meta-analysis comparing viral load results from paired dried blood spot and plasma specimens analyzed with commonly used viral load testing technologies. METHODS AND FINDINGS Standard databases, conferences, and gray literature were searched in 2013 and 2018. Nearly all studies identified (60) were conducted between 2007 and 2018. Data from 40 of the 60 studies were included in the meta-analysis, which accounted for a total of 10,871 paired dried blood spot:plasma data points. We used random effects models to determine the bias, accuracy, precision, and misclassification for each viral load technology and to account for between-study variation. Dried blood spot specimens produced consistently higher mean viral loads across all technologies when compared to plasma specimens. However, when used to identify treatment failure, each technology compared best to plasma at a threshold of 1,000 copies/ml, the present World Health Organization recommended treatment failure threshold. Some heterogeneity existed between technologies; however, 5 technologies had a sensitivity greater than 95%. Furthermore, 5 technologies had a specificity greater than 85% yet 2 technologies had a specificity less than 60% using a treatment failure threshold of 1,000 copies/ml. The study's main limitation was the direct applicability of findings as nearly all studies to date used dried blood spot samples prepared in laboratories using precision pipetting that resulted in consistent input volumes. CONCLUSIONS This analysis provides evidence to support the implementation and scale-up of dried blood spot specimens for viral load testing using the same 1,000 copies/ml treatment failure threshold as used with plasma specimens. This may support improved access to viral load testing in resource-limited settings lacking the required infrastructure and cold chain storage for testing with plasma specimens.
Collapse
Affiliation(s)
- Lara Vojnov
- Clinton Health Access Initiative, Boston, Massachusetts, United States of America
- * E-mail:
| | - Sergio Carmona
- National Health Laboratory Service, Johannesburg, South Africa
| | - Clement Zeh
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | | | - Debrah Boeras
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | - Marta R. Prescott
- Clinton Health Access Initiative, Boston, Massachusetts, United States of America
| | | | - Souleymane Sawadogo
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Windhoek, Namibia
| | - Christiane Adje-Toure
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Abidjan, Cote d’Ivoire
| | - Guoqing Zhang
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | | | - Wendy S. Stevens
- National Health Laboratory Service, Johannesburg, South Africa
- Department of Molecular Medicine and Haematology, University of the Witwatersrand, Johannesburg, South Africa
| | - Meg Doherty
- World Health Organization, Geneva, Switzerland
| | - Chunfu Yang
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | - Heather Alexander
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | - Trevor F. Peter
- Clinton Health Access Initiative, Boston, Massachusetts, United States of America
| | - John Nkengasong
- Center for Global Health, Division of Global HIV/TB, US Centers for Disease Control, Atlanta, Georgia, United States of America
| | | |
Collapse
|
2
|
OUP accepted manuscript. J Appl Lab Med 2022; 7:1120-1130. [DOI: 10.1093/jalm/jfac026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 03/01/2022] [Indexed: 11/12/2022]
|
3
|
Yacouba A, Congo M, Dioma GK, Somlare H, Coulidiaty D, Ouattara K, Sangare L. Whatman FTA cards versus plasma specimens for the quantitation of HIV-1 RNA using two real-time PCR assays. Access Microbiol 2020; 2:acmi000138. [PMID: 32974600 PMCID: PMC7497827 DOI: 10.1099/acmi.0.000138] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 02/17/2020] [Indexed: 11/24/2022] Open
Abstract
Background Several studies have compared the use of dried blot spot (DBS) as an alternative to plasma specimens, mainly using Whatman 903 cards as filter paper. The aim of this study was to evaluate the use of Whatman FTA card (FTA card) specimens for HIV-1 viral load testing compared to plasma specimens using two real-time PCR assays manufactured by Roche and Abbott. Methodology A cross-sectional study was conducted between April 2017 and September 2017 on HIV-1 patients admitted to Yalgado Ouédraogo Teaching Hospital. Paired FTA cards and plasma specimens were collected and analysed using the Abbott Real-Time HIV-1 assay (Abbott) and COBAS AmpliPrep/COBAS TaqMan v2.0 (Roche). Results In total, 107 patients were included. No statistical differences (P>0.05) were observed between the mean viral loads obtained from the FTA cards and those of the plasma specimens using the Roche and Abbott assays. In total, 29 samples with Roche and 15 samples with Abbott assay showed discrepant results. At viral loads of ≤1000 copies ml−1, the sensitivity and specificity of the FTA cards were 78.6 and 100% with Roche, and 92.3 and 95.9% with Abbott, respectively. Both the Roche and Abbott assays showed good correlation and agreement between the FTA cards and plasma values. Conclusion Our study demonstrates the feasibility of using FTA card filter paper for HIV-1 viral load testing. However, further studies will be required for the validation of the use of FTA card filter paper in HIV-1 treatment monitoring.
Collapse
Affiliation(s)
- Abdourahamane Yacouba
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - Malika Congo
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - Gérard Komonsira Dioma
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - Hermann Somlare
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - David Coulidiaty
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - Kalifa Ouattara
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| | - Lassana Sangare
- Unité de Formation et des Recherches en Sciences de la Santé, Université Ouaga I Pr Joseph KI-ZERBO, 03 B.P. 7021 Ouaga 03, Ouagadougou, Burkina Faso
- Laboratoire National de Référence du VIH/Sida et des Infections Sexuellement Transmissibles, Centre Hospitalier Universitaire Yalgado Ouédraogo, 03 B.P. 7022 Ouaga 03, Ouagadougou, Burkina Faso
| |
Collapse
|
4
|
Hanhauser E, Bono MS, Vaishnav C, Hart AJ, Karnik R. Solid-Phase Extraction, Preservation, Storage, Transport, and Analysis of Trace Contaminants for Water Quality Monitoring of Heavy Metals. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:2646-2657. [PMID: 32069029 DOI: 10.1021/acs.est.9b04695] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Accurate quantification of trace contaminants currently requires collection, preservation, and transportation of large volumes (250-1000 mL) of water to centralized laboratories, which impedes monitoring of trace-level pollutants in many resource-limited environments. To overcome this logistical challenge, we propose a new paradigm for trace contaminant monitoring based on dry preservation: solid-phase extraction, preservation, storage, transport, and analysis of trace contaminants (SEPSTAT). We show that a few grams of low-cost, commercially available cation exchange resin can be repurposed to extract heavy metal cations from water samples even in the presence of background ions, dryly preserve these cations for at least 24 months, and release them by acid elution for accurate quantification. A compact, human-powered device incorporating the sorbent removes spiked contaminants from real water samples in a few minutes. The device can be stored and transported easily and produces a sample suitable for measurement by standard methods, predicting the original sample heavy metal concentration generally within an error of 15%. These results suggest that, by facilitating the collection, storage, handling, and transportation of water samples and by enabling cost-effective use of high-throughput capital-intensive instruments, SEPSTAT has the potential to increase the ease and reach of water quality monitoring of trace contaminants.
Collapse
Affiliation(s)
- Emily Hanhauser
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Tata Center for Technology and Design, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Michael S Bono
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Tata Center for Technology and Design, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Chintan Vaishnav
- Tata Center for Technology and Design, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Sloan School of Management, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - A John Hart
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Rohit Karnik
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
5
|
Khamduang W, Kaewbundit A, Duangmano A, Hongjaisee S, Klinbuayaem V, Halue G, Chutanunta A, Sirirungsi W, Jourdain G, Ngo-Giang-Huong N. HIV RNA measurement in dried blood spots of HIV-infected patients in Thailand using Abbott m2000 system. PLoS One 2020; 15:e0227929. [PMID: 31978113 PMCID: PMC6980635 DOI: 10.1371/journal.pone.0227929] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 01/02/2020] [Indexed: 11/18/2022] Open
Abstract
World Health Organization recommends using dried blood spots (DBS) for HIV RNA viral load (VL) measurement whenever plasma processing is not convenient or feasible. DBS collected from 80 treatment-naïve HIV-infected patients presenting in three hospitals of two different regions of Thailand were shipped to a central laboratory along with corresponding plasma specimens. Viral load was measured in both DBS and plasma using the Abbott m2000 system. HIV RNA levels were strongly correlated (r = 0.94) with a mean of differences of 0.23 log10 copies/mL. Using the 1,000 copies/mL cut-off, the sensitivity of DBS was 97% (95%CI, 91–100%) and specificity was 75% (95%CI, 19–99%). DBS are useful to scale-up HIV RNA VL testing in settings with limited access to VL testing.
Collapse
Affiliation(s)
- Woottichai Khamduang
- Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand.,Infectious Diseases Research Unit, Division of Clinical Microbiology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand.,Institut de Recherche pour le Développement (IRD), Chiangmai, Thailand
| | - Ampika Kaewbundit
- Institut de Recherche pour le Développement (IRD), Chiangmai, Thailand
| | - Amonrat Duangmano
- Institut de Recherche pour le Développement (IRD), Chiangmai, Thailand
| | - Sayamon Hongjaisee
- Research Institute for Health Sciences, Chiang Mai University, Chiangmai, Thailand
| | | | | | | | - Wasna Sirirungsi
- Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand
| | - Gonzague Jourdain
- Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand.,Institut de Recherche pour le Développement (IRD), Chiangmai, Thailand.,Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, MA, United States of America
| | - Nicole Ngo-Giang-Huong
- Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand.,Institut de Recherche pour le Développement (IRD), Chiangmai, Thailand.,Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, MA, United States of America
| |
Collapse
|
6
|
Thepbundit V, Ngo-Giang-Huong N, Salvadori N, Laolue A, Kunyanone N, Sata-Un J, Jourdain G, Sirirungsi W, Khamduang W. Feasibility of using dried blood spots for HIV viral load testing among HIV-infected individuals in Thailand using QIAGEN QIAsymphony-artus HIV-1 platform. J Med Virol 2019; 91:1652-1659. [PMID: 31095748 DOI: 10.1002/jmv.25506] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 04/25/2019] [Accepted: 05/14/2019] [Indexed: 01/08/2023]
Abstract
In settings where plasma preparation and sample centralization are not feasible or inconvenient, dried blood spots (DBS) could be used as an alternative specimen to plasma to assess antiretroviral treatment response among HIV-infected individuals. This study was aimed to (1) validate the recent QIAsymphony-artus assay for DBS HIV viral load (VL) and (2) assess the feasibility of measuring HIV VL on DBS using this assay in Thailand. Ethylenediaminetetraacetic acid-blood samples from 99 HIV-infected individuals were used to prepare paired DBS and plasma. Also, DBS samples were shipped to three distant hospitals in the northern region. After short-term storage, DBS were returned by regular post to the AMS laboratory and were re-tested for HIV VL using the same platform. HIV VL results were compared using Pearson's correlation and Bland-Altman analysis. DBS HIV VL fairly correlated to plasma HIV VL (R = 0.62) with a mean difference of 0.02 log10 IU/mL (SD = 1.06). A high correlation (R = 0.79) was observed between HIV VL in DBS before and after shipping (mean difference = 0.14 log10 IU/mL, SD = 0.74), indicating good stability of HIV RNA in DBS. DBS can be used as an alternative specimen for HIV VL monitoring in Thailand. However, measurement of HIV VL with the QIAGEN QIAsymphony-artus assay should be improved, especially the DBS pre-extraction process.
Collapse
Affiliation(s)
- Viraporn Thepbundit
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand
| | - Nicole Ngo-Giang-Huong
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand.,Unité Internationale174-PHPT, Health and Societies Department, Institut de Recherche pour Développement (IRD), Chiangmai, Thailand.,Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, Massachusetts
| | - Nicolas Salvadori
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand.,Unité Internationale174-PHPT, Health and Societies Department, Institut de Recherche pour Développement (IRD), Chiangmai, Thailand
| | - Auswin Laolue
- Department of Medical Laboratory, Wiangsa Hospital, Nan, Thailand
| | - Naowarat Kunyanone
- Department of Medical Laboratory, Chiangrai Prachanukroh Hospital, Chiangrai, Thailand
| | - Jaggrit Sata-Un
- Department of Medical Laboratory, Thoeng Hospital, Chiangrai, Thailand
| | - Gonzague Jourdain
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand.,Unité Internationale174-PHPT, Health and Societies Department, Institut de Recherche pour Développement (IRD), Chiangmai, Thailand.,Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, Massachusetts
| | - Wasna Sirirungsi
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand
| | - Woottichai Khamduang
- Department of Medical Technology, Faculty of Associated Medical Sciences (AMS), Chiang Mai University, Chiangmai, Thailand.,Infectious Diseases Research Unit, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiangmai, Thailand
| |
Collapse
|
7
|
Mahajan S, Choudhary MC, Kumar G, Gupta E. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system. Virusdisease 2018; 29:141-146. [PMID: 29911146 PMCID: PMC6003055 DOI: 10.1007/s13337-018-0441-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Accepted: 02/26/2018] [Indexed: 01/05/2023] Open
Abstract
Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log10 IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log10 IU/ml was comparable to DBS (3.93; range 0-7.24) log10 IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r2 = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.
Collapse
Affiliation(s)
- Supriya Mahajan
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Manish Chandra Choudhary
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Guresh Kumar
- Department of Clinical Research, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Ekta Gupta
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| |
Collapse
|
8
|
Performance of Virological Testing for Early Infant Diagnosis: A Systematic Review. J Acquir Immune Defic Syndr 2017; 75:308-314. [PMID: 28418986 DOI: 10.1097/qai.0000000000001387] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Improved access to both maternal antiretroviral therapy and infant prophylaxis may have an impact on the performance of virological assays for diagnosis of HIV infection in infants. This systematic review was performed to assess the diagnostic accuracy of virological testing at birth as well as the performance of virological testing on dried blood spots at 6 weeks among HIV- and antiretroviral (ARV)-exposed infants. METHODS A systematic review was performed for studies published between January 1, 2009 and January 30, 2015. The search strategy included studies related to HIV, nucleic acid amplification tests, and newborns/infants and queried PubMed, Embase, the Cochrane Library, LILACS as well as several conference proceedings. Two independent reviewers collected studies and extracted data. The final analysis includes summary estimates of the sensitivities and specificities of the virological assays assessed. The GRADE approach was used to assess the overall quality of evidence and Quality Assessment of Diagnostic Accuracy Studies was used to evaluate the risk of bias in the studies. RESULTS A total of 2243 records were screened with a final selection of 5 manuscripts. To assess the test characteristics of virological testing at birth, 2 studies were used to calculate a pooled sensitivity of 69.3% (95% confidence interval: 61.1 to 77.4) and a specificity of 99.9% (98.6-100%). The quality of evidence to support the sensitivity of assays at birth was low, whereas the quality of evidence for the specificity of such tests was intermediate-high. In terms of the performance of virological testing on dried blood spots for HIV- and ARV-exposed infants, 3 studies were used to calculate a pooled sensitivity of 99.4% (98.3-100.00%) and specificity of 99.6% (99.1-100.00%). The quality of evidence for both outcomes was low. CONCLUSION The performance of polymerase chain reaction at birth demonstrates low sensitivity and high specificity, reflecting the difficulty of detecting intrapartum infections at birth and transmission dynamics. In addition, there is no evidence to suggest poor performance of virological testing on dried blood spots for ARV-exposed infants. Overall, given the very limited and low-quality evidence, further research is needed to assess the accuracy of polymerase chain reaction at different time points and in the context of more effective prevention of mother-to-child transmission interventions.
Collapse
|
9
|
Chang J, de Sousa A, Sabatier J, Assane M, Zhang G, Bila D, Vaz P, Alfredo C, Cossa L, Bhatt N, Koumans EH, Yang C, Rivadeneira E, Jani I, Houston JC. Performance characteristics of finger-stick dried blood spots (DBS) on the determination of human immunodeficiency virus (HIV) treatment failure in a pediatric population in Mozambique. PLoS One 2017; 12:e0181054. [PMID: 28704560 PMCID: PMC5509298 DOI: 10.1371/journal.pone.0181054] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Accepted: 06/26/2017] [Indexed: 12/13/2022] Open
Abstract
Quantitative plasma viral load (VL) at 1000 copies /mL was recommended as the threshold to confirm antiretroviral therapy (ART) failure by the World Health Organization (WHO). Because of ongoing challenges of using plasma for VL testing in resource-limited settings (RLS), especially for children, this study collected 717 DBS and paired plasma samples from children receiving ART ≥1 year in Mozambique and compared the performance of DBS using Abbott’s VL test with a paired plasma sample using Roche’s VL test. At a cut-off of 1000 copies/mL, sensitivity of DBS using Abbott DBS VL test was 79.9%, better than 71.0% and 63.9% at 3000 and 5000 copies/mL, respectively. Specificities were 97.6%, 98.8%, 99.3% at 1000, 3000, and 5000 copies/mL, respectively. The Kappa value at 1000 copies/mL, 0.80 (95% CI: 0.73, 0.87), was higher than 0.73 (95% CI: 0.66, 0.80) and 0.66 (95% CI: 0.59, 0.73) at 3000, 5000 copies/mL, respectively, also indicating better agreement. The mean difference between the DBS and plasma VL tests with 95% limits of agreement by Bland-Altman was 0.311 (-0.908, 1.530). Among 73 children with plasma VL between 1000 to 5000 copies/mL, the DBS results were undetectable in 53 at the 1000 copies/mL threshold. While one DBS sample in the Abbott DBS VL test may be an alternative method to confirm ART failure at 1000 copies/mL threshold when a plasma sample is not an option for treatment monitoring, because of sensitivity concerns between 1,000 and 5,000 copies/ml, two DBS samples may be preferred accompanied by careful patient monitoring and repeat testing.
Collapse
Affiliation(s)
- Joy Chang
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
- * E-mail: (jc); (jch)
| | - Amina de Sousa
- Instituto Nacional de Saúde (INS), Ministry of Health, Maputo, Mozambique
| | - Jennifer Sabatier
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
| | - Mariamo Assane
- Instituto Nacional de Saúde (INS), Ministry of Health, Maputo, Mozambique
| | - Guoqing Zhang
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
| | - Dulce Bila
- Fundação Ariel Glaser contra o SIDA Pediátrico (Ariel), Maputo, Mozambique
| | - Paula Vaz
- Fundação Ariel Glaser contra o SIDA Pediátrico (Ariel), Maputo, Mozambique
| | - Charity Alfredo
- Centers for Disease Control and Prevention, Maputo, Mozambique
| | - Loide Cossa
- Instituto Nacional de Saúde (INS), Ministry of Health, Maputo, Mozambique
| | - Nilesh Bhatt
- Instituto Nacional de Saúde (INS), Ministry of Health, Maputo, Mozambique
| | - Emilia H. Koumans
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
| | - Chunfu Yang
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
| | - Emilia Rivadeneira
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
| | - Ilesh Jani
- Instituto Nacional de Saúde (INS), Ministry of Health, Maputo, Mozambique
| | - James C. Houston
- Centers for Disease Control and Prevention (CDC), Atlanta, GA, United States of America
- * E-mail: (jc); (jch)
| |
Collapse
|
10
|
Makadzange AT, Boyd FK, Chimukangara B, Masimirembwa C, Katzenstein D, Ndhlovu CE. A Simple Phosphate-Buffered-Saline-Based Extraction Method Improves Specificity of HIV Viral Load Monitoring Using Dried Blood Spots. J Clin Microbiol 2017; 55:2172-2179. [PMID: 28468852 PMCID: PMC5483919 DOI: 10.1128/jcm.00176-17] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 04/19/2017] [Indexed: 12/30/2022] Open
Abstract
Although Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) systems are widely used in sub-Saharan Africa for early infant diagnosis of HIV from dried blood spots (DBS), viral load monitoring with this system is not practical due to nonspecific extraction of both cell-free and cell-associated viral nucleic acids. A simplified DBS extraction technique for cell-free virus elution using phosphate-buffered saline (PBS) may provide an alternative analyte for lower-cost quantitative HIV virus load (VL) testing to monitor antiretroviral therapy (ART). We evaluated the CAP/CTM v2.0 assay in 272 paired plasma and DBS specimens using the cell-free virus elution method and determined the level of agreement, sensitivity, and specificity at thresholds of target not detected (TND), target below the limit of quantification (BLQ) (<20 copies/ml in plasma or <400 copies/ml in DBS), and VL of <1,000 copies/ml, and VL of <5,000 copies/ml. Reported plasma VL ranged from TND, or <20, to 5,781,592 copies/ml, and DBS VL ranged from TND, or <400, to 467,600 copies/ml. At <1000 copies/ml, agreement between DBS and plasma was 96.7% (kappa coefficient, 0.93; P < 0.0001). The mean difference between DBS and plasma VL values was -1.06 log10 copies/ml (95% confidence interval [CI], -1.17, -0.97; P < 0.0001). At a treatment failure threshold of >1,000 copies/ml, the sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) were 92.7%, 100%, 100%, and 94.3%, respectively. PBS elution of DBS offers a sensitive and specific method for monitoring plasma viremia among adults and children on ART at the WHO-recommended threshold of >1,000 copies/ml on the Roche CAP/CTM system.
Collapse
Affiliation(s)
- A Tariro Makadzange
- Ragon Institute of MGH, MIT and Harvard, Cambridge, Massachussetts, USA
- Department of Medicine, University of Zimbabwe College of Health Sciences, Harare, Zimbabwe
| | - F Kathryn Boyd
- Department of Medicine, University of Zimbabwe College of Health Sciences, Harare, Zimbabwe
| | - Benjamin Chimukangara
- Department of Virology, National Health Laboratory Service, University of KwaZulu-Natal, Durban, South Africa
| | | | - David Katzenstein
- Division of Infectious Diseases, Stanford University, Palo Alto, California, USA
| | - Chiratidzo E Ndhlovu
- Department of Medicine, University of Zimbabwe College of Health Sciences, Harare, Zimbabwe
| |
Collapse
|
11
|
Performance of Roche CAP/CTM HIV-1 qualitative test version 2.0 using dried blood spots for early infant diagnosis. J Virol Methods 2015; 229:12-5. [PMID: 26706730 DOI: 10.1016/j.jviromet.2015.12.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Revised: 12/14/2015] [Accepted: 12/14/2015] [Indexed: 11/21/2022]
Abstract
In the context of early infant diagnosis (EID) decentralization in sub-Saharan Africa, dried blood spot (DBS) is now widely used for HIV proviral DNA detection in resource-limited settings. A new version of CAP/CTM (version 2) has been introduced, recently by Roche Diagnosis as a new real-time PCR assay to replace previous technologies on qualitative detection of HIV-1 DNA using whole blood and DBS samples. The objective of this study was to evaluate CAP/CTM version 2 compared to CAP/CTM version 1 and Amplicor on DBS. A total of 261 DBS were collected from children aged 4 weeks to 17 months born from HIV-seropositive mothers and tested by the three techniques. CAP/CTM version 2 showed 100% of agreement with Amplicor including 74 positive results and 187 negative results. CAP/CTM version 2 versus CAP/CTM version 1 as well as CAP/CTM version 1 versus Amplicor showed two discordant results giving a sensitivity of 98.6%, specificity of 99.5%, positive predictive value of 98.6% and negative predictive value of 99.5%. The concordance was 99.12% (95% of confidence interval) giving a Kappa coefficient of 0.97 (p<0.001). These findings confirmed the expected good performance of CAP/CTM version 2 for HIV-1 EID.
Collapse
|
12
|
Performance of an Early Infant Diagnostic Test, AmpliSens DNA-HIV-FRT, Using Dried Blood Spots Collected from Children Born to Human Immunodeficiency Virus-Infected Mothers in Ukraine. J Clin Microbiol 2015; 53:3853-8. [PMID: 26447114 DOI: 10.1128/jcm.02392-15] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Accepted: 10/05/2015] [Indexed: 11/20/2022] Open
Abstract
An accurate accessible test for early infant diagnosis (EID) is crucial for identifying HIV-infected infants and linking them to treatment. To improve EID services in Ukraine, dried blood spot (DBS) samples obtained from 237 HIV-exposed children (≤18 months of age) in six regions in Ukraine in 2012 to 2013 were tested with the AmpliSens DNA-HIV-FRT assay, the Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) HIV-1 Qual test, and the Abbott RealTime HIV-1 Qualitative assay. In comparison with the paired whole-blood results generated from AmpliSens testing at the oblast HIV reference laboratories in Ukraine, the sensitivity was 0.99 (95% confidence interval [CI], 0.95 to 1.00) for the AmpliSens and Roche CAP/CTM Qual assays and 0.96 (95% CI, 0.90 to 0.98) for the Abbott Qualitative assay. The specificity was 1.00 (95% CI, 0.97 to 1.00) for the AmpliSens and Abbott Qualitative assays and 0.99 (95% CI, 0.96 to 1.00) for the Roche CAP/CTM Qual assay. McNemar analysis indicated that the proportions of positive results for the tests were not significantly different (P > 0.05). Cohen's kappa (0.97 to 0.99) indicated almost perfect agreement among the three tests. These results indicated that the AmpliSens DBS and whole-blood tests performed equally well and were comparable to the two commercially available EID tests. More importantly, the performance characteristics of the AmpliSens DBS test meets the World Health Organization EID test requirements; implementing AmpliSens DBS testing might improve EID services in resource-limited settings.
Collapse
|
13
|
Aitken SC, Wallis CL, Stevens W, de Wit TR, Schuurman R. Stability of HIV-1 Nucleic Acids in Dried Blood Spot Samples for HIV-1 Drug Resistance Genotyping. PLoS One 2015; 10:e0131541. [PMID: 26147689 PMCID: PMC4493047 DOI: 10.1371/journal.pone.0131541] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 06/03/2015] [Indexed: 11/19/2022] Open
Abstract
Dried blood spots (DBS) are an easy to collect sample-type that can stabilize biological material at ambient temperature for transport and storage, making them ideal for use in resource-limited settings (RLS). We investigated the effect of storage temperature and duration on ability to detect mixed HIV-1 viral RNA populations, and subsequently viral RNA populations in a background of proviral DNA. Part one of the study used DBS samples of whole blood spiked with specific quantities of HIV-1 subtype-B and -C RNA to study mixed virus population detection. Part two used DBS comprising of HIV-1 subtype-B proviral DNA containing U1 cells combined with HIV-1 subtype-C RNA to mimic HIV-1 infected clinical samples as a model system to study the relative stability of HIV-1 RNA and DNA in DBS. Prepared DBS were stored at -20 °C and +30 °C for periods of one day, one, two, and four weeks. Samples were genotyped to determine changes in the detection of mixtures in the sample over time. From two weeks onwards, storage at +30 °C resulted in gradual, time-related reduction in the detection of mixed virus population at log10 VL 4.0 but not at log10 5.0. Proviral DNA and viral RNA were both stable for at least 52 weeks when stored at -20 °C, compared to progressive RNA decay over time at +30 °C. DBS storage conditions and duration had a significant effect on HIV-1 RNA amplification. Our results demonstrate that DBS storage at ambient temperature (+30 °C) should not exceed two weeks, with long-term storage at -20 °C or lower.
Collapse
Affiliation(s)
- Susan C. Aitken
- Department of Medical Microbiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | | | - Wendy Stevens
- Department of Molecular Medicine and Hematology, University of the Witwatersrand, Johannesburg, South Africa
- National Health Laboratory Services, Johannesburg, South Africa
| | - Tobias Rinke de Wit
- PharmAccess International, Amsterdam, The Netherlands
- Global Health Department, Amsterdam Institute for Global Health and Development (AIGHD), Academic Medical Center, Amsterdam, the Netherlands
| | - Rob Schuurman
- Department of Medical Microbiology, University Medical Centre Utrecht, Utrecht, The Netherlands
- * E-mail:
| |
Collapse
|
14
|
HIV-1 variability and viral load technique could lead to false positive HIV-1 detection and to erroneous viral quantification in infected specimens. J Infect 2015; 71:368-76. [PMID: 26033694 DOI: 10.1016/j.jinf.2015.05.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 05/12/2015] [Accepted: 05/25/2015] [Indexed: 11/23/2022]
Abstract
OBJECTIVES Viral load (VL) testing is used for early HIV diagnosis in infants (EID) and for detecting early therapeutic failure events, but can be affected by HIV genetic variability. Dried blood samples (DBS) increase VL access and EID in remote settings and when low blood volume is available. METHODS This study compares VL values using Siemens VERSANT HIV-1 RNA 1.0 kPCR assay (kPCR) and Roche CAP/CTM Quantitative test v2.0 (CAP/CTM v2.0) in 176 DBS carrying different HIV-1 variants collected from 69 Equatoguinean mothers and their infants with known HIV-1 status (71 infected, 105 uninfected). RESULTS CAP/CTM v2.0 provided false positive VLs in 11 (10.5%) cases. VL differences above 0.5 log10 were observed in 42/49 (87.5%) DBS, and were above 1 log10 in 18 cases. CAP/CTM v2.0 quantified all the 41 specimens with previously inferred HIV-1 variant by phylogenetic analysis (68.3% recombinants) whereas kPCR only identified 90.2% of them, and was unable to detect 14.3% of 21 CRF02_AG viruses. CAP/CTM v2.0 showed higher sensitivity than kPCR (95.8% vs. 70.1%), quantifying a higher rate of viruses in infected DBS from subjects under antiretroviral exposure at sampling time compared to kPCR (94.7% vs. 96.2%, p-value<0.001). kPCR showed maximum specificity (100%) whereas for CAP/CTM v2.0 was 89.5%. CONCLUSIONS VL assays should increase their sensitivity and specificity to avoid overestimated HIV-1 quantifications, which could be interpreted as virological failure events, or false negative diagnostic results due to genetic variability. We recommend using the same VL technique for each patient during antiretroviral therapy monitoring.
Collapse
|
15
|
Dokubo EK, Evans J, Winkelman V, Cyrus S, Tobler LH, Asher A, Briceno A, Page K. Comparison of Hepatitis C Virus RNA and antibody detection in dried blood spots and plasma specimens. J Clin Virol 2014; 59:223-7. [PMID: 24529844 PMCID: PMC4026019 DOI: 10.1016/j.jcv.2014.01.014] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 01/19/2014] [Indexed: 12/11/2022]
Abstract
BACKGROUND Current diagnostic tests for Hepatitis C Virus (HCV) involve phlebotomy and serologic testing for HCV antibodies (anti-HCV) and RNA, which are not always feasible. Dried blood spots (DBS) present a minimally invasive sampling method and are suitable for sample collection, storage and testing. OBJECTIVES To assess the utility of DBS in HCV detection, we evaluated the sensitivity and specificity of DBS for anti-HCV and HCV RNA detection compared to plasma specimens. STUDY DESIGN This cross-sectional validation study was conducted in the context of an existing prospective study of HCV in young injection drug users. Blood samples were collected by venipuncture into serum separator tubes (SST) and via finger stick onto Whatman 903(®) protein-saver cards. Plasma samples and eluates from the DBS were tested for anti-HCV using either a third generation enzyme-linked or chemiluminescent immunoassay (IA), and HCV RNA using discriminatory HCV transcription-mediated amplification assay (dHCV TMA). DBS results were compared to their corresponding plasma sample results. RESULTS 148 participants were tested for anti-HCV and 132 participants were tested for HCV RNA. For anti-HCV, the sensitivity of DBS was 70%, specificity was 100%, positive predictive value (PPV) was 100%, negative predictive value (NPV) was 76% and Kappa was 0.69. For HCV RNA, the sensitivity of DBS was 90%, specificity was 100%, PPV was 100%, NPV was 94% and Kappa was 0.92. CONCLUSIONS DBS are sensitive and very specific in detecting anti-HCV and HCV RNA, demonstrate good correlation with plasma results, and have potential to facilitate diagnosis of HCV infection.
Collapse
Affiliation(s)
- E Kainne Dokubo
- University of California San Francisco, 50 Beale Street, Suite 1200, San Francisco, CA 94105, USA.
| | - Jennifer Evans
- University of California San Francisco, 50 Beale Street, Suite 1200, San Francisco, CA 94105, USA
| | - Valerie Winkelman
- Creative Testing Solutions, 2424 West Erie Drive, Tempe, AZ 85282, USA
| | - Sherri Cyrus
- Creative Testing Solutions, 2424 West Erie Drive, Tempe, AZ 85282, USA
| | - Leslie H Tobler
- Blood Systems Research Institute, 270 Masonic Avenue, San Francisco, CA 94118, USA
| | - Alice Asher
- University of California San Francisco, 50 Beale Street, Suite 1200, San Francisco, CA 94105, USA
| | - Alya Briceno
- University of California San Francisco, 50 Beale Street, Suite 1200, San Francisco, CA 94105, USA
| | - Kimberly Page
- University of California San Francisco, 50 Beale Street, Suite 1200, San Francisco, CA 94105, USA
| |
Collapse
|
16
|
Smit PW, Sollis KA, Fiscus S, Ford N, Vitoria M, Essajee S, Barnett D, Cheng B, Crowe SM, Denny T, Landay A, Stevens W, Habiyambere V, Perriens JH, Peeling RW. Systematic review of the use of dried blood spots for monitoring HIV viral load and for early infant diagnosis. PLoS One 2014; 9:e86461. [PMID: 24603442 PMCID: PMC3945725 DOI: 10.1371/journal.pone.0086461] [Citation(s) in RCA: 87] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Accepted: 12/10/2013] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID. METHODS AND FINDINGS Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52-100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78-100% compared to plasma at VL below 1000 copies/ml, but this increased to 100% at a threshold of 5000 copies/ml. Unlike a plasma VL test which measures only cell free HIV RNA, a DBS VL also measures proviral DNA as well as cell-associated RNA, potentially leading to false positive results when using DBS. The systematic review showed that specificity was close to 100% at DBS VL above 5000 copies/ml, and this threshold would be the most reliable for predicting true virologic failure using DBS. For early infant diagnosis, DBS has a sensitivity of 100% compared to fresh whole blood or plasma in all studies. CONCLUSIONS Although limited data are available for EID, DBS offer a highly sensitive and specific sampling strategy to make viral load monitoring and early infant diagnosis more accessible in remote settings. A standardized approach for sampling, storing, and processing DBS samples would be essential to allow successful implementation. TRIAL REGISTRATION PROSPERO Registration #: CRD42013003621.
Collapse
Affiliation(s)
- Pieter W. Smit
- Department of Clinical Research, London School of Hygiene and Tropical Medicine, London, United Kingdom
| | - Kimberly A. Sollis
- Department of Clinical Research, London School of Hygiene and Tropical Medicine, London, United Kingdom
| | - Susan Fiscus
- Department of Microbiology and Immunology, University of North Carolina, Chapel Hill, North Carolina, United States of America
| | - Nathan Ford
- Department of HIV/AIDS, World Health Organization, Geneva, Switzerland
| | - Marco Vitoria
- Department of HIV/AIDS, World Health Organization, Geneva, Switzerland
| | - Shaffiq Essajee
- HIV, Medicine and Science, Clinton Health Access Initiative, New York, New York, United States of America
| | - David Barnett
- Department of Haematology, UK NEQAS for Leucocyte Immunophenotyping, Sheffield, United Kingdom
| | - Ben Cheng
- Department of Technology and Innovation, Pangaea Global AIDS Foundation, San Fransisco, California, United States of America
| | - Suzanne M. Crowe
- Centre for Biomedical Research, Burnet Institute, Melbourne, Australia
| | - Thomas Denny
- Department of Medicine, Duke Human Vaccine Institute and Center for HIV/AIDS Vaccine Immunology, Durham, North Carolina, United States of America
| | - Alan Landay
- Department of Immunology- Microbiology, Rush University Medical Center, Chicago, Illinois, United States of America
| | - Wendy Stevens
- Department of Molecular Medicine and Haematology, University of the Witwatersrand, Johannesburg, South Africa
| | | | | | - Rosanna W. Peeling
- Department of Clinical Research, London School of Hygiene & Tropical Medicine, London, United Kingdom
| |
Collapse
|
17
|
Prospective evaluation of diagnostic accuracy of dried blood spots from finger prick samples for determination of HIV-1 load with the NucliSENS Easy-Q HIV-1 version 2.0 assay in Malawi. J Clin Microbiol 2014; 52:1343-51. [PMID: 24501032 DOI: 10.1128/jcm.03519-13] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
HIV-1 viral load (VL) testing is not widely available in resource-limited settings. The use of finger prick dried blood spot (FP-DBS) samples could remove barriers related to sample collection and transport. Measurement of VL using DBS from EDTA venous blood (VB-DBS) in place of plasma has previously been validated using the NucliSENS Easy-Q HIV-1 v2.0 assay, but information on the accuracy of FP-DBS samples for measuring VL is limited. This prospective study, conducted at Thyolo District Hospital in southern Malawi, compared VL levels measured on FP-DBS samples and plasma using the NucliSENS Easy-Q HIV-1 v2.0 assay. Comparability was assessed by means of agreement and correlation (131 patients with VLs of ≥100 copies/ml), sensitivity, and specificity (612 patients on antiretroviral treatment [ART]). Samples of EDTA venous blood and FP-DBS from 1,009 HIV-infected individuals were collected and prepared in the laboratory. Bland-Altman analysis found good agreement between plasma and FP-DBS VL levels, with a mean difference of -0.35 log10, and 95% limits of agreement from -1.26 to 0.55 log10. FP-DBS had a sensitivity of 88.7% (95% confidence interval [CI], 81.1 to 94.4%) and a specificity of 97.8% (95% CI, 96.1 to 98.9%) using a 1,000-copies/ml cut point and a sensitivity of 83.0% (95% CI, 73.4 to 90.1%) and a specificity of 100% (95% CI, 99.3 to 100%) using a 5,000-copies/ml cut point. This study shows that FP-DBS is an acceptable alternative to plasma for measuring VL using the NucliSENS Easy-Q HIV-1 v2.0. We are conducting a second study to assess the proficiency of health workers at preparing FP-DBS in primary health care clinics.
Collapse
|
18
|
Smit PW, Elliott I, Peeling RW, Mabey D, Newton PN. An overview of the clinical use of filter paper in the diagnosis of tropical diseases. Am J Trop Med Hyg 2014; 90:195-210. [PMID: 24366501 PMCID: PMC3919219 DOI: 10.4269/ajtmh.13-0463] [Citation(s) in RCA: 95] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Accepted: 11/04/2013] [Indexed: 12/16/2022] Open
Abstract
Tropical infectious diseases diagnosis and surveillance are often hampered by difficulties of sample collection and transportation. Filter paper potentially provides a useful medium to help overcome such problems. We reviewed the literature on the use of filter paper, focusing on the evaluation of nucleic acid and serological assays for diagnosis of infectious diseases using dried blood spots (DBS) compared with recognized gold standards. We reviewed 296 eligible studies and included 101 studies evaluating DBS and 192 studies on other aspects of filter paper use. We also discuss the use of filter paper with other body fluids and for tropical veterinary medicine. In general, DBS perform with sensitivities and specificities similar or only slightly inferior to gold standard sample types. However, important problems were revealed with the uncritical use of DBS, inappropriate statistical analysis, and lack of standardized methodology. DBS have great potential to empower healthcare workers by making laboratory-based diagnostic tests more readily accessible, but additional and more rigorous research is needed.
Collapse
Affiliation(s)
- Pieter W. Smit
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| | - Ivo Elliott
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| | | | | | - Paul N. Newton
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
19
|
Wu G, Srivastava J, Zaman MH. Stability measurements of antibodies stored on paper. Anal Biochem 2013; 449:147-54. [PMID: 24361717 DOI: 10.1016/j.ab.2013.12.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Revised: 10/23/2013] [Accepted: 12/09/2013] [Indexed: 10/25/2022]
Abstract
Reagent storage has been a long-standing challenge for diagnostics, especially those designed for low-resource settings and point-of-care applications. In general, the stability of a reagent relies on careful temperature control, often by refrigeration, which is costly and often unavailable in these remote settings. Poor reagent integrity can negatively affect the reproducibility and reliability of an assay. Given the recent interest in paper-based devices designed for quantitative analysis in point-of-care settings, a better understanding of reagent stability on filter paper is critical for proper device use and its longevity. In this article, we present an independent method to examine the stability of reconstituted antibodies that were stored on filter paper using flow cytometry. We validated the method by measuring the activity as measured by the mean fluorescence intensity (MFI) of antibodies stored with known stabilizers. Furthermore, we demonstrated the potential of our method to screen the influence of other paper treatments and storage processes on antibody stability, which may be applicable to the storage of reagents on paper in general.
Collapse
Affiliation(s)
- Grace Wu
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Jaya Srivastava
- Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Muhammad H Zaman
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
| |
Collapse
|
20
|
Diouara AAM, Diop-Ndiaye H, Kebe-Fall K, Tchiakpè E, Ndiaye O, Ayouba A, Peeters M, Mboup S, Kane CT. Dried blood spots for HIV-1 drug resistance genotyping in decentralized settings in Senegal. J Med Virol 2013; 86:45-51. [PMID: 24122937 DOI: 10.1002/jmv.23778] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/09/2013] [Indexed: 11/11/2022]
Abstract
The aim of this study was to evaluate the use for HIV-1 drug resistance testing dried blood spots collected in remote areas and sent under field conditions to a reference laboratory and also to document virological failure in patients with suspected treatment failure. Samples were collected from patients receiving first line ART at 11 hospital sites around country, kept at room temperature (<37°C) and sent within 15 days maximum to the reference laboratory. Viral nucleic acids were obtained by magnetic extraction with NucliSENS (bioMérieux, Marcy l'Etoile, France). Genotyping of HIV-1 pol gene was performed using the ANRS protocol. Drug resistance mutations were analyzed according to the Stanford University HIV database version 6.0.8. Two hundred thirty one HIV-infected adults' on HAART first line regimen composed study population. The median time on ART was 18 months (range 6-68). Regardless of the treatment duration, the overall rate of virological failure (VL ≥ 3 log10 cp/ml) was 23.8% (n = 55/231). HIV genotypes were obtained successfully in 94.5% (n = 52/55). Drug resistance mutation was found in 41/52 patients in virological failure, for 17.7% (n = 41/231) an overall rate of drug resistance mutations. M184V/I was the most frequent mutation occurring, followed by K103N. Phylogenetic analysis of the 52 genotyped viral isolates showed the predominance of CRF02_AG with 62% (n = 32/52). Use of a DBS specimen is suitable to assist national programs for monitoring in remote areas HIV drug resistance in resources limited-settings.
Collapse
|
21
|
Analytical performance of an automated assay quantifying HIV-1 from dried blood spots. J Clin Virol 2013; 57:271-3. [DOI: 10.1016/j.jcv.2013.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2013] [Revised: 03/02/2013] [Accepted: 03/02/2013] [Indexed: 11/17/2022]
|
22
|
Quantitation of cytomegalovirus DNA load in dried blood spots correlates well with plasma viral load. J Clin Microbiol 2013; 51:2360-4. [PMID: 23678066 DOI: 10.1128/jcm.00316-13] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
An assay to accurately quantitate cytomegalovirus (CMV) load in finger-stick-collected dried blood spots (DBS) could potentially be useful for field studies or for analyzing patient self-collected specimens. We therefore assessed CMV DNA load in paired venipuncture-collected plasma samples and finger-stick DBS, using a previously validated quantitative PCR assay. Assay variability, sensitivity, and changes in viral load during antiviral therapy in finger-stick DBS were compared to the reference plasma quantitative PCR assay, using 106 prospectively collected pairs of finger-stick DBS and plasma samples from 35 solid-organ transplant (SOT) patients. The DBS assay showed good agreement with the reference plasma viral load assay on the log10 scale (Pearson correlation coefficient, 0.92; P < 0.001). The 95% limit of detection of the DBS assay was estimated at 2,700 plasma copies/ml (675 plasma IU/ml). In 94% (76/81) of paired DBS and plasma samples above the limit of detection, the difference in CMV load was <1 log10. CMV viral load changes during antiviral treatment were comparable in plasma and DBS. We conclude that finger-stick DBS provides a convenient sample type for quantitation of CMV load that correlates well with plasma levels. Future studies to optimize and evaluate this methodology for patient self-collected samples are warranted.
Collapse
|
23
|
Evaluation of quantification of HIV-1 RNA viral load in plasma and dried blood spots by use of the semiautomated Cobas Amplicor assay and the fully automated Cobas Ampliprep/TaqMan assay, version 2.0, in Kisumu, Kenya. J Clin Microbiol 2013; 51:1208-18. [PMID: 23390278 DOI: 10.1128/jcm.03048-12] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specificity, negative and positive predictive values (NPV and PPV, respectively), concordance, and agreement between HIV-1 viral load measurements using plasma and DBS specimens obtained from 512 HIV-1-infected pregnant females enrolled in the Kisumu Breastfeeding Study and tested with the Cobas Amplicor and CAP/CTM assays. The sensitivity and NPV of viral load detection in DBS specimens were higher with CAP/CTM (sensitivity, 100%; 95% confidence interval [CI], 99.1 to 100.0%; NPV, 100%; 95% CI, 59.0 to 100.0%) than the Cobas Amplicor (sensitivity, 96.6%; 95% CI, 94.3 to 98.1%; NPV, 58.8%; 95% CI, 40.7 to 75.4%). The PPVs were comparable between both assays when using DBS. The specificity of viral load detection in DBS specimens was lower with CAP/CTM (77.8%; 95% CI, 40.0 to 97.2%) than that of the Cobas Amplicor (95.2%; 95% CI, 76.2 to 99.9%). Good concordance and agreement were observed when paired plasma and DBS specimens were tested with both assays. Lower specificity with the CAP/CTM is likely due to proviral HIV-1 DNA amplification and lower detection limits with RT-PCR. However, the CAP/CTM has better sensitivity and higher throughput than the Cobas Amplicor. These findings suggest that DBS may be a suitable alternative to plasma when using RT-PCR, which could increase access to viral load monitoring in resource-limited settings.
Collapse
|
24
|
Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing. J Clin Microbiol 2012; 50:4128-30. [PMID: 23052309 DOI: 10.1128/jcm.02549-12] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.
Collapse
|
25
|
Masciotra S, Khamadi S, Bilé E, Puren A, Fonjungo P, Nguyen S, Girma M, Downing R, Ramos A, Subbarao S, Ellenberger D. Evaluation of blood collection filter papers for HIV-1 DNA PCR. J Clin Virol 2012; 55:101-6. [DOI: 10.1016/j.jcv.2012.06.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 06/14/2012] [Accepted: 06/15/2012] [Indexed: 10/28/2022]
|
26
|
David S, Sachithanandham J, Jerobin J, Parasuram S, Kannangai R. Comparison of HIV-1 RNA level estimated with plasma and DBS samples: A pilot study from India (South). Indian J Med Microbiol 2012. [DOI: 10.4103/0255-0857.103759] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
27
|
Montgomery ET, van der Pol B, van der Straten A, Ramjee G, de Bruyn G, Chipato T, Blanchard K, Padian NS. Discrepancies in diagnosis of incident HIV infection between antibody- and DNA-based tests in a phase III prevention trial in southern Africa. Int J STD AIDS 2012; 23:649-52. [DOI: 10.1258/ijsa.2009.009124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Dried blood spots (DBS) are widely used to test for HIV in a variety of research and service delivery settings; however, uniform guidelines regarding collection, storage and DNA extraction processes have neither been developed nor evaluated. Previously published reports suggested DBS may be stored at room temperature for up to 60 days, and intensive stability tests have shown that DBS can withstand high temperatures, humidity and freeze–thawing. During the implementation of a large randomized controlled trial (RCT) in southern Africa, with HIV acquisition as the primary endpoint, we observed 65 instances when DBS samples collected from the same day as a positive HIV antibody test yielded negative DNA polymerase chain reaction (PCR) results. The source of this discrepancy may have been due to inadequate specimen volume, filter paper or DNA extraction procedures, but were most likely due to storage conditions that have been reported as acceptable in other settings.
Collapse
Affiliation(s)
- E T Montgomery
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | - B van der Pol
- Indiana University School of Medicine, Infectious Disease Laboratory, Indianapolis, IN
| | - A van der Straten
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
- Center for AIDS Prevention Studies, Department of Medicine, University of California San Francisco, San Francisco, CA, USA
| | - G Ramjee
- Medical Research Council, Kwazulu-Natal
| | - G de Bruyn
- Perinatal HIV Research Unit, Johannesburg, South Africa
| | - T Chipato
- University of Zimbabwe-University of California San Francisco Research Collaborative Programme in Women's Health, Harare, Zimbabwe
| | - K Blanchard
- Ibis Reproductive Health, Cambridge, MA, USA
- Ibis Reproductive Health, Johannesburg, South Africa
| | - N S Padian
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | | |
Collapse
|
28
|
[Dried blood spots for monitoring HIV infection in Public Health Programs in developing countries]. Enferm Infecc Microbiol Clin 2012; 31:100-7. [PMID: 22560588 DOI: 10.1016/j.eimc.2012.03.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2011] [Revised: 12/30/2011] [Accepted: 03/16/2012] [Indexed: 11/22/2022]
Abstract
As access to antiretroviral treatment increases in the developing countries, efforts towards making it easier and less costly to collect, store, and deliver the biological samples to reference laboratories, where the serological and genetic diagnosis techniques are performed, have become a high priority. Blood sampling on filter papers is an inexpensive and practical alternative to plasma for antiretroviral treatment monitoring in countries with limited resources and no access to cold chains or refrigeration. The main clinical applications and uses of blood-sampling onto filter papers (dried blood spots [DBS]) are reviewed, focusing on how these can be applied in monitoring HIV infection, particularly for use in National Health Programs in developing countries, or in resource-limited settings. A review is presented of studies that have used the DBS technique for quantifying viral load, analysis of antiretroviral drug-resistance mutations, early infant diagnosis, adult serological diagnosis, detection of viral p24 antigen, and molecular epidemiology of HIV-1, in different geographical locations. Those variables that could affect the use of DBS, particularly in the HIV field, as well as explaining how these procedures can be optimised to increase their sensitivity are also reviewed. The aim of this study was to review the advantages of implementing the DBS technique in the HIV field, especially in resource-constrained regions.
Collapse
|
29
|
Stevens DS, Crudder CH, Domingo GJ. Post-extraction stabilization of HIV viral RNA for quantitative molecular tests. J Virol Methods 2012; 182:104-10. [PMID: 22433512 DOI: 10.1016/j.jviromet.2012.03.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2011] [Revised: 02/13/2012] [Accepted: 03/05/2012] [Indexed: 11/19/2022]
Abstract
Two approaches to stabilize viral nucleic acid in processed clinical specimens were evaluated. HIV-1 RNA extracted from clinical specimens was stabilized in a dry matrix in a commercial product (RNAstable, Biomatrica, San Diego, CA, USA) and in a reverse-transcription reaction mixture in liquid form as cDNA. As few as 145 HIV-1 genome copies of viral RNA are reliably stabilized by RNAstable at 45°C for 92 days and in the cDNA format at 45°C for 7 days as determined by real-time PCR. With RNAstable the R(2) at days 1, 7, and 92 were 0.888, 0.871, and 0.943 when compared to baseline viral load values. The cDNA generated from the same clinical specimens was highly stable with an R(2) value of 0.762 when comparing viral load determinations at day 7 to baseline values. In conclusion viral RNA stabilized in a dry RNAstable matrix is highly stable for long periods of time at high temperatures across a substantial dynamic range. Viral RNA signal can also be stabilized in liquid in the form of cDNA for limited periods of time. Methods that reduce reliance on the cold chain and preserve specimen integrity are critical for extending the reach of molecular testing to low-resource settings. Products based on anhydrobiosis, such as the RNAstable should be evaluated further to support viral pathogen diagnosis.
Collapse
|
30
|
Vidya M, Saravanan S, Rifkin S, Solomon SS, Waldrop G, Mayer KH, Solomon S, Balakrishnan P. Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay. J Virol Methods 2012; 181:177-81. [PMID: 22401801 DOI: 10.1016/j.jviromet.2012.02.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Revised: 02/19/2012] [Accepted: 02/22/2012] [Indexed: 11/17/2022]
Abstract
High costs and stringent requirements for storage and transport of plasma, often prohibit the availability of HIV viral load quantification in resource-limited settings. Dried blood spots (DBS) represent a better method of specimen collection that removes many of these logistical and technical limitations. The present study aimed to assess the performance of the Abbott m2000rt assay for quantitation of HIV-1 RNA in DBS specimens using plasma as a "gold standard" for comparison. One hundred paired DBS and plasma specimens were collected from patients infected with HIV, who were 18 years and older during routine visits to a private tertiary-care clinic in Chennai, India. HIV-1 RNA was extracted manually and then detected using the m2000rt assay. The mean plasma and DBS viral loads were 4.27 (95% CI: 2.65, 5.88) and 4.14 (95% CI: 1.96, 6.32) log copies/mL, respectively. The overall sensitivity of DBS reached 95%; with sensitivities of 62%, 88% and 100% when stratified by viral load ranges of ≤1000, 1000-3000 and >3000 copies/mL, respectively. An over quantitation of the viral load with DBS was observed in pairs with plasma viral load<3000 copies/mL [d=-0.3 log copies/mL (ranging from -0.1 to 0.6 log copies/mL)]. The study showed a strong concordance in RNA levels between plasma and DBS. The use of DBS specimens should be considered for HIV monitoring and for detection of virologic failure in resource-limited settings.
Collapse
Affiliation(s)
- Madhavan Vidya
- YRG Centre for AIDS Research and Education, Chennai, Tamil Nadu, India
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Maritz J, Preiser W, van Zyl GU. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots. J Clin Virol 2012; 53:106-9. [DOI: 10.1016/j.jcv.2011.12.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Revised: 11/28/2011] [Accepted: 12/01/2011] [Indexed: 10/14/2022]
|
32
|
Wessman MJ, Theilgaard Z, Katzenstein TL. Determination of HIV status of infants born to HIV-infected mothers: A review of the diagnostic methods with special focus on the applicability of p24 antigen testing in developing countries. ACTA ACUST UNITED AC 2011; 44:209-15. [DOI: 10.3109/00365548.2011.627569] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
33
|
Lee CE, Sri Ponnampalavanar S, Syed Omar SF, Mahadeva S, Ong LY, Kamarulzaman A. Evaluation of the Dried Blood Spot (DBS) Collection Method as a Tool for Detection of HIV Ag/Ab, HBsAg, anti-HBs and anti-HCV in a Malaysian Tertiary Referral Hospital. ANNALS OF THE ACADEMY OF MEDICINE, SINGAPORE 2011. [DOI: 10.47102/annals-acadmedsg.v40n10p448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Introduction: Dried blood spot (DBS) collection is an appealing alternative to whole blood or plasma sampling, as it has technical and economic advantages over the latter. Materials and Methods: A prospective cross-sectional study was conducted at a Malaysian tertiary referral hospital from November 2009 to March 2010. One hundred and fifty paired specimens of DBS and plasma were analysed by the standard assays for HIV Ag/Ab, HBsAg, anti-HBS and anti-HCV, separately (total 600 paired specimens). DBS sample titres were then compared to the results of plasma testing, which was used as the gold standard. Results: For the HIV Ag/Ab assay with a cut-off point of 0.35 Relative Light Units (RLUs), the sensitivity and specificity were both 100%. For the HBsAg assay, the sensitivity was 96.5% and the specificity was 97.8%, with a cut-off point of 1.72 RLUs. Sensitivity for the anti-HBs test was 74.2% and the specificity was 86.9%, using a cut-off point of 0.635 RLUs. For the anti-HCV assay, the sensitivity was 97.3% and the specificity was 100%, with a cut-off point of 0.10 RLUs. Conclusion: DBS is an ideal choice to be used as a screening tool for the detection of HIV, Hepatitis B and Hepatitis C virus infections. However, different cut-off values need to be used for the validation of test positivity in DBS samples because the small amount of blood in the DBS specimens leads to lower assay titres.
Key words: Anti-HBs, Anti-HCV, dried blood spot (DBS), HBsAg, Human immunodeficiency virus (HIV), HIV Ag/Ab
Collapse
|
34
|
Huang S, Erickson B, Mak WB, Salituro J, Abravaya K. A novel RealTime HIV-1 Qualitative assay for the detection of HIV-1 nucleic acids in dried blood spots and plasma. J Virol Methods 2011; 178:216-24. [PMID: 21968095 DOI: 10.1016/j.jviromet.2011.09.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 09/10/2011] [Accepted: 09/19/2011] [Indexed: 12/17/2022]
Abstract
Abbott RealTime HIV-1 Qualitative is an in vitro real-time PCR assay for detecting HIV-1 nucleic acids in human plasma and dried blood spots (DBS). The assay was designed to be used in diagnosis of HIV-1 infections in pediatric and adult patients, with an emphasis on the applicability in resource-limited settings. Use of DBS facilitates specimen collection from remote areas and transportation to testing laboratories. Small sample input requirement facilitates testing of specimens with limited collection volume. The Abbott RealTime HIV-1 Qualitative assay is capable of detecting HIV-1 group M subtypes A-H, group O and group N samples. HIV-1 virus concentrations detected with 95% probability were 80 copies/mL of plasma using the plasma protocol, and 2469 copies/mL of whole blood using the DBS protocol. The assay detected HIV-1 infection in 13 seroconversion panels an average 10.5 days earlier than an HIV-1 antibody test and 4.9 days earlier than a p24 antigen test. For specimens collected from 6 weeks to 18 months old infants born to HIV-1 positive mothers, assay results using both the DBS and plasma protocols agreed well with the Roche Amplicor HIV-1 DNA Test version 1.5 (95.5% agreement for DBS and 97.8% agreement for plasma).
Collapse
Affiliation(s)
- Shihai Huang
- Abbott Molecular Inc., 1300 E Touhy Avenue, Des Plaines, IL 60018-3315, USA.
| | | | | | | | | |
Collapse
|
35
|
Pirillo MF, Recordon-Pinson P, Andreotti M, Mancini MG, Amici R, Giuliano M. Quantification of HIV-RNA from dried blood spots using the Siemens VERSANT® HIV-1 RNA (kPCR) assay. J Antimicrob Chemother 2011; 66:2823-6. [PMID: 21930572 DOI: 10.1093/jac/dkr383] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Simplified methods for virological monitoring in resource-limited settings are increasingly needed. We evaluated the performance of the VERSANT(®) HIV-1 RNA (kPCR) assay for the determination of HIV-1 viral load from dried blood spots (DBS). Assay sensitivity and correlation with plasma quantification values were assessed. METHODS A total of 98 DBS were prepared from fresh blood samples of HIV-infected patients. DBS were kept at room temperature for 6 weeks or 7 months before processing while the corresponding plasma samples were stored at -80°C. DBS were first pre-treated in a special DBS buffer. The DBS extracts and the plasma samples were then purified and amplified using the VERSANT assay reagents. RESULTS In the first series of tests, performed after 6 weeks of storage, there was good correlation between quantification of viral load in plasma and in DBS (r = 0.95, P < 0.001). The detection rate in DBS was 100% when plasma levels were >1000 copies/mL. The sensitivity and specificity of the DBS assay were 88.2% [95% confidence interval (CI) 79.4-93.6] and 69.2% (95% CI 42.0-87.4), respectively. Using the 5000 copies/mL threshold (defining virological failure in resource-limited settings), both positive and negative predictive values were high (95.2% and 87.5%, respectively). After 7 months of storage there was a modest decrease in the detection rate and less significant correlations for samples with HIV-RNA <5000 copies/mL. CONCLUSIONS Quantification of HIV-RNA from DBS by the VERSANT automated sample preparation and detection method can be used to diagnose virological failure in HIV-positive patients.
Collapse
Affiliation(s)
- Maria Franca Pirillo
- Department of Therapeutic Research and Medicines Evaluation, Istituto Superiore di Sanità, Rome, Italy
| | | | | | | | | | | |
Collapse
|
36
|
Okonji JA, Basavaraju SV, Mwangi J, Shiraishi RW, Odera M, Ouma K, Pitman JP, Marum LH, Ou CY, Zeh C. Comparison of HIV-1 detection in plasma specimens and dried blood spots using the Roche COBAS Ampliscreen HIV-1 test in Kisumu, Kenya. J Virol Methods 2011; 179:21-5. [PMID: 21777620 DOI: 10.1016/j.jviromet.2011.07.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Revised: 06/30/2011] [Accepted: 07/04/2011] [Indexed: 11/18/2022]
Abstract
The World Health Organization recommends screening donor blood for HIV in centralized laboratories. This recommendation contributes to quality, but presents specimen transport challenges for resource-limited settings which may be relieved by using dried blood spots (DBS). In sub-Saharan Africa, most countries screen donor blood with serologic assays only. Interest in window period reduction has led blood services to consider adding HIV nucleic acid testing (NAT). The U.S. Food and Drug Administration (FDA) mandates that HIV-1 NAT blood screening assays have a 95% detection limit at or below 100 copies/ml and 5000 copies/ml for pooled and individual donations, respectively. The Roche COBAS Ampliscreen HIV-1 test, version 1.5, used for screening whole blood or components for transfusion, has not been tested with DBS. We compared COBAS Ampliscreen HIV-1 RNA detection limits in DBS and plasma. An AIDS Clinical Trials Group, Viral Quality Assurance laboratory HIV-1 standard with a known viral load was used to create paired plasma and DBS standard nine member dilution series. Each was tested in 24 replicates with the COBAS Ampliscreen. A probit analysis was conducted to calculate 95% detection limits for plasma and DBS, which were 23.8 copies/ml (95% CI 15.1-51.0) for plasma and 106.7 copies/ml (95% CI 73.8-207.9) for DBS. The COBAS Ampliscreen detection threshold with DBS suggests acceptability for individual donations, but optimization may be required for pooled specimens.
Collapse
Affiliation(s)
- Jully A Okonji
- Centre for Biomedical Research and Technology, Kenya Medical Research Institute (KEMRI), Off Kisumu-Busia Road, P.O. Box 1578-40100, Kisumu, Kenya.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Economic evaluation of monitoring virologic responses to antiretroviral therapy in HIV-infected children in resource-limited settings. AIDS 2011; 25:1143-51. [PMID: 21505319 DOI: 10.1097/qad.0b013e3283466fab] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Antiretroviral therapy (ART) management for HIV-infected children is critical in many resource-constrained countries. We investigated the cost-effectiveness and cost-utility of different frequencies of monitoring plasma viral load among HIV-positive children initiating ART in a resource-limited setting. DESIGN/METHODS A stochastic agent-based simulation model was built and directly informed by a cohort of 304 HIV-infected children starting ART in Thailand between 2001 and 2009. The model simulated the expected costs and clinical outcomes over time according to different viral load monitoring frequencies and initiation of second-line therapies when appropriate. RESULTS The optimal frequency of viral load monitoring was found to be annual, after a single screening at 6 months. Associated costs of viral load monitoring and appropriate ART would approximately triple current treatment costs. Compared with current conditions, a single screening during the first year of ART led to a 58.4% reduction in the total person-years of virological failure with annual monitoring leading to a 76.6% reduction. The incremental cost per quality adjusted life year gained from the optimal monitoring frequency was estimated as US$ 68,084 when including costs of ART and US$ 7224 without ART costs. The estimated cost attributed to preventing 1 year of virological failure was US$ 3393 with ART costs and US$ 359 without ART costs. CONCLUSION Even infrequent viral load monitoring is likely to provide substantial clinical benefit to HIV-infected children on ART. Viral load monitoring can be considered cost-effective in many resource-limited settings. However, the costs associated with second-line therapies could be a barrier to its economic feasibility.
Collapse
|
38
|
RNA versus DNA (NucliSENS EasyQ HIV-1 v1.2 versus Amplicor HIV-1 DNA test v1.5) for early diagnosis of HIV-1 infection in infants in Senegal. J Clin Microbiol 2011; 49:2590-3. [PMID: 21543563 DOI: 10.1128/jcm.02402-10] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The objective of this study was to compare the performance of the NucliSENS EasyQ HIV-1 v1.2 platform (bioMérieux, France) to the Amplicor HIV-1 DNA test v1.5 (Roche Molecular Systems, Switzerland) in detecting HIV-1 infection in infants using venipuncture-derived whole blood in tubes and dried blood spots. A total of 149 dried blood spots and 43 EDTA-anticoagulated peripheral blood samples were collected throughout Dakar and other areas in Senegal from infants and children aged 3 weeks to 24 months who were born to HIV-1-infected mothers. Samples were tested using the NucliSENS and Amplicor technologies. The NucliSENS and Amplicor results were 100% concordant using either EDTA-anticoagulated peripheral blood or dried blood spots. Compared to Amplicor, the sensitivity and specificity of the NucliSENS test were 100%. The NucliSENS EasyQ HIV-1 RNA assay performed as well as the Amplicor HIV-1 DNA test in detecting HIV-1 infection in infants. In addition, this platform can give an indication of the viral load baseline. The NucliSENS EasyQ platform is a good alternative for early infant diagnosis of HIV-1 infection.
Collapse
|
39
|
Winters M, Lloyd R, Shahidi A, Brown S, Holodniy M. Use of dried clinical samples for storing and detecting influenza RNA. Influenza Other Respir Viruses 2011; 5:413-7. [PMID: 21668673 PMCID: PMC5780658 DOI: 10.1111/j.1750-2659.2011.00253.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Please cite this paper as: Winters et al. (2011) Use of dried clinical samples for storing and detecting influenza RNA. Influenza and Other Respiratory Viruses 5(6), 413–417. Background Most clinical samples collected for diagnostic influenza testing and monitoring require refrigerated or frozen storage or shipment, which imparts logistic and cost burdens. The ability to store and ship dried clinical specimens under ambient conditions for influenza testing would significantly reduce costs and protect samples from improper storage or equipment failure, especially in remote or resource‐limited areas. Objectives To evaluate the collection and storage of dried clinical samples on a transport matrix (ViveST™, ST) for influenza RNA testing by real‐time reverse‐transcription PCR (RT‐PCR). Methods Viral transport medium from swab or sputum samples was applied to ST, dried, and stored under ambient conditions from 2 days to 6 months. Additional aliquots of samples were frozen. Testing of frozen and ST‐stored samples was performed using the WHO/CDC real‐time influenza A (H1N1) RT‐PCR protocol and compared to the Luminex xTAG RVP assay. Results ST‐stored samples yielded slightly higher threshold cycle values (median 2·54 cycles) compared to frozen samples tested in parallel. This difference was consistent regardless of viral input. There was no significant difference in signal recovery between samples stored for 1 week versus samples stored for 3 weeks, or from three samples stored for 6 months. Qualitatively, clinical specimens stored on ST were 100% concordant (36/36) with frozen samples for detecting the presence of influenza A RNA. Conclusion ST‐processed dried specimens produced similar rates of seasonal or novel 2009 HIN1 influenza RNA detection compared to conventional sample processing and thus presents a viable alternative to refrigerated or frozen samples.
Collapse
Affiliation(s)
- Mark Winters
- VA Palo Alto Health Care System, Palo Alto, CA, USA.
| | | | | | | | | |
Collapse
|
40
|
Effect on transmission of HIV-1 resistance of timing of implementation of viral load monitoring to determine switches from first to second-line antiretroviral regimens in resource-limited settings. AIDS 2011; 25:843-50. [PMID: 21192233 DOI: 10.1097/qad.0b013e328344037a] [Citation(s) in RCA: 72] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND There is concern that antiretroviral therapy (ART) use with only clinical monitoring for failure will result in high rates of transmission of virus with resistance to drugs currently in use. METHODS A stochastic simulation model of transmission of HIV, natural history and the effect of ART, was developed and used to predict the proportion of new infections with resistance according to whether and when viral load monitoring is introduced. RESULTS In our base model, there was predicted to be 12.4% of new HIV infections with primary antiretroviral resistance in 2020 if clinical monitoring is used throughout, compared with 5.4 and 6.1% if viral load-guided switching (based on viral load measured every 6 months, with switch determined by a value >500 copies/ml) was introduced in 2010 or 2015, respectively. The death rate for those on ART was lowest when viral load monitoring was used, but the overall death rate in all infected people was higher if viral load monitoring was introduced at the expense of scale-up in HIV diagnosis and ART initiation beyond their 2010 coverage levels (4.7 compared with 3.1 per 100 person-years). INTERPRETATION To preserve current first-line drugs for the long term there is an eventual need for some form of cheap and practical viral load monitoring in resource-limited settings. However, a delay in introduction of 5 years has limited consequences for resistance transmission so the current priority for countries' ART programmes is to increase HIV testing and provide treatment for all those in need of ART.
Collapse
|
41
|
Dried blood spots in HIV monitoring: applications in resource-limited settings. Bioanalysis 2011; 2:1893-908. [PMID: 21083497 DOI: 10.4155/bio.10.120] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
By the end of 2008, 4 million people were receiving antiretroviral treatment for HIV/AIDS in low- and middle-income countries. In industrialized countries, monitoring of treatment with viral load measurements and drug resistance testing is the standard of care to ensure early detection of treatment failure and a prompt switch to a fully active second-line regimen, before drug-resistant mutations accumulate. These tests, however, require highly specialized laboratories and stringent procedures for storage and shipment of plasma, and are rarely available in resource-limited settings. Therefore, treatment failure in such settings is usually not detected until patients develop severe immunodeficiency, at which stage widespread resistance is likely. Dried blood spots (DBS) are easy to collect and store, and can be a convenient alternative to plasma in settings with limited laboratory capacity. This review provides an overview of possible applications of DBS technologies in the monitoring of HIV treatment, with the main focus on viral load quantification and drug resistance testing.
Collapse
|
42
|
Niemz A, Ferguson TM, Boyle DS. Point-of-care nucleic acid testing for infectious diseases. Trends Biotechnol 2011; 29:240-50. [PMID: 21377748 DOI: 10.1016/j.tibtech.2011.01.007] [Citation(s) in RCA: 568] [Impact Index Per Article: 43.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2010] [Revised: 01/17/2011] [Accepted: 01/20/2011] [Indexed: 02/05/2023]
Abstract
Nucleic acid testing for infectious diseases at the point of care is beginning to enter clinical practice in developed and developing countries; especially for applications requiring fast turnaround times, and in settings where a centralized laboratory approach faces limitations. Current systems for clinical diagnostic applications are mainly PCR-based, can only be used in hospitals, and are still relatively complex and expensive. Integrating sample preparation with nucleic acid amplification and detection in a cost-effective, robust, and user-friendly format remains challenging. This review describes recent technical advances that might be able to address these limitations, with a focus on isothermal nucleic acid amplification methods. It briefly discusses selected applications related to the diagnosis and management of tuberculosis, HIV, and perinatal and nosocomial infections.
Collapse
Affiliation(s)
- Angelika Niemz
- Keck Graduate Institute of Applied Life Sciences, 535 Watson Drive, Claremont, CA 91711, USA.
| | | | | |
Collapse
|
43
|
Desai D, Wu G, Zaman MH. Tackling HIV through robust diagnostics in the developing world: current status and future opportunities. LAB ON A CHIP 2011; 11:194-211. [PMID: 21125097 PMCID: PMC5181793 DOI: 10.1039/c0lc00340a] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Over the last thirty years, the world has seen HIV circulate the globe, affecting 33 million people to date and killing 2 million people a year. The disease has affected developed and developing countries alike, and in the U.S., remains one of the top ten leading causes of death. Many regions of the world are highly impacted by this disease, including sub-Saharan Africa, South and South-East Asia, and Eastern Europe. Fortunately, multilateral, global efforts, along with successful developments in diagnostic tools and anti-retroviral drugs (ARVs) have successfully curbed the spread of HIV over the last ten years. In spite of this fact, access to HIV treatment and preventive healthcare is varying and limited in developing countries. A lack of healthcare infrastructure, financial support, and healthcare workers are some logistical factors that are responsible. HIV stigmatization, discrimination, and inadequate education pose additional social challenges that are hindering countries from advancing in HIV prevention. This review focuses on current technological tools that are used for HIV diagnosis and ongoing research that is aimed at addressing the conditions in low-resource settings. Recent developments in microfluidic applications and mobile health technologies are promising approaches to building a compact, portable, and robust device that can provide information-rich, real-time diagnoses. We also discuss the role that governments, healthcare workers, and even researchers can play in order to increase the acceptance of newly introduced devices and treatments in rural communities.
Collapse
|
44
|
Comparative effectiveness of dried plasma HIV-1 viral load testing in Brazil using ViveST for sample collection. J Clin Virol 2010; 49:245-8. [DOI: 10.1016/j.jcv.2010.08.017] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Revised: 08/20/2010] [Accepted: 08/28/2010] [Indexed: 11/18/2022]
|
45
|
Li P, Ruel T, Fujimoto K, Hatano H, Yukl S, Eller LA, Liegler T, Kamya M, Gassasira A, Dorsey G, Rosenthal PJ, Havlir DV, Wong JK. Novel application of Locked Nucleic Acid chemistry for a Taqman assay for measuring diverse human immunodeficiency virus type 1 subtypes. J Virol Methods 2010; 170:115-20. [PMID: 20863855 DOI: 10.1016/j.jviromet.2010.09.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2009] [Revised: 09/10/2010] [Accepted: 09/14/2010] [Indexed: 11/24/2022]
Abstract
There remains a need for sensitive and cost-effective assays to monitor therapy in human immunodeficiency virus type-1 (HIV-1) infection. However, the genetic diversity of HIV poses difficulties for traditional real-time PCR assays that require long oligonucleotides probes. LNA™ probes may be useful in overcoming these limits to traditional probe design. A new application of LNA™ chemistry in a Taqman assay applicable to a wide range of HIV-1 subtypes is described. This assay, based on a 13-mer LNA™ probe that matches the majority of HIV-1 sequences in the Los Alamos database, exhibited a wide dynamic range (10(1)-10(7) copies of HIV DNA), high sensitivity (limit of detection of 1 copy of HIV DNA in 10(5) cells), and broad applicability to a range of HIV-1 subtypes (including A, B, C, D, F, H, B/C, and A/E CRFs). Using the LNA™ probe assay, HIV-1 DNA was detected in all dried blood spots (DBS) from treatment naïve HIV-1 positive Ugandan children, and HIV DNA levels significantly correlated with viral RNA levels in plasma (r=0.765, p<0.0001). This approach to Taqman probe design should be explored further for use in diagnosis and monitoring of HIV in resource-limited settings, especially where several subtypes co-circulate.
Collapse
Affiliation(s)
- Peilin Li
- University of California, San Francisco (UCSF), Department of Medicine, San Francisco, CA 94121, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Schito ML, D'Souza MP, Owen SM, Busch MP. Challenges for rapid molecular HIV diagnostics. J Infect Dis 2010; 201 Suppl 1:S1-6. [PMID: 20225941 DOI: 10.1086/650394] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
The introduction of serological point-of-care assays 10 years ago dramatically changed the way that human immunodeficiency virus (HIV) infection was identified and diagnosed. Testing at the point of care has lead to a dramatic increase in the number of individuals who are screened and, most importantly, receive their HIV test result. As the AIDS epidemic continues to mature and scientific advances in prevention and treatment are evaluated and implemented, there is a need to identify acute (viremic preseroconversion) infections and to discriminate "window phase" infections from those that are serologically positive, especially in resource-limited settings, where the majority of vulnerable populations reside and where the incidence of HIV infection is highest. Rapid testing methods are now at a crossroads. There is opportunity to implement and evaluate the incremental diagnostic usefulness of new test modalities that are based on sophisticated molecular diagnostic technologies and that can be performed in settings where laboratory infrastructure is minimal. The way forward requires sound scientific judgment and an ability to further develop and implement these tests despite a variety of technical, social, and operational hurdles, to declare success.
Collapse
Affiliation(s)
- Marco L Schito
- Henry Jackson Foundation for the Advancement of Military Medicine, Division of AIDS, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Maryland 20817, USA.
| | | | | | | |
Collapse
|
47
|
Lilian RR, Bhowan K, Sherman GG. Early diagnosis of human immunodeficiency virus-1 infection in infants with the NucliSens EasyQ assay on dried blood spots. J Clin Virol 2010; 48:40-3. [PMID: 20211580 DOI: 10.1016/j.jcv.2010.02.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2009] [Revised: 02/04/2010] [Accepted: 02/10/2010] [Indexed: 11/17/2022]
Abstract
BACKGROUND More routine laboratories in South Africa are equipped to perform quantitative than qualitative HIV viral detection assays. The accessibility of early infant diagnosis would be improved if a quantitative viral load (VL) assay performed on dried blood spots (DBS) could accurately diagnose HIV-infection. The VL assay routinely used in the country has not previously been assessed on DBS for early infant diagnosis. OBJECTIVES To determine the accuracy of the NucliSens EasyQ assay (bioMerieux, Lyon, France) on DBS for early infant diagnosis of HIV in a subtype C-infected population. STUDY DESIGN Stored DBS samples collected from children presenting for HIV testing were analyzed. DBS EasyQ VL results were compared to the child's HIV status as determined by a whole blood HIV DNA PCR result. RESULTS The EasyQ assay was performed on 235 stored DBS samples from 71 HIV-infected and 164 HIV-uninfected children. Of the 216 infants (children aged 12 months or less) tested, all 52 HIV-infected infants were detected (sensitivity of 100%). Six of 164 HIV-uninfected infants yielded false positive results (specificity 96.3%). All false positive and six of the true positive infants had VL<3.7 log IU/ml. These 12 (5.6%) infants would require repeat testing to differentiate true from false positives. Using a threshold above 3.7 log IU/ml (equivalent to 4 log copies/ml) to define a positive result would yield an accurate diagnosis in 204 (94.4%) infants. CONCLUSIONS DBS EasyQ VL assays provide an accurate option for early infant diagnosis in low resource settings.
Collapse
Affiliation(s)
- R R Lilian
- Paediatric HIV Diagnostic Syndicate, Wits Health Consortium, 8 Blackwood Avenue, Parktown, Johannesburg, South Africa
| | | | | |
Collapse
|
48
|
Lofgren SM, Morrissey AB, Chevallier CC, Malabeja AI, Edmonds S, Amos B, Sifuna DJ, von Seidlein L, Schimana W, Stevens WS, Bartlett JA, Crump JA. Evaluation of a dried blood spot HIV-1 RNA program for early infant diagnosis and viral load monitoring at rural and remote healthcare facilities. AIDS 2009; 23:2459-66. [PMID: 19741481 PMCID: PMC2890230 DOI: 10.1097/qad.0b013e328331f702] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To assess technical and operational performance of a dried blood spot (DBS)-based HIV-1 RNA service for remote healthcare facilities in a low-income country. DESIGN A method comparison and operational evaluation of DBS RNA against conventional tests for early infant diagnosis of HIV and HIV RNA quantitation under field conditions in Tanzania. METHODS DBSs were prepared and plasma was frozen at -80 degrees C. DBSs were mailed and plasma couriered to a central laboratory for testing using the Abbott m2000 system. Infant diagnosis DBSs were also tested for HIV-1 DNA by ROCHE COBAS AmpliPrep/COBAS TaqMan System. Results of DBS RNA were compared with conventional tests; program performance was described. RESULTS Among 176 infant diagnosis participants, using a threshold of at least 1000 copies/ml, sensitivity and specificity of DBS versus plasma RNA were 1.00 and 0.99, and of DBS RNA versus DBS DNA were 0.97 and 1.00. Among 137 viral load monitoring participants, when plasma and DBS RNA were compared, r value was 0.9709; r value was 0.9675 for at least 5000 copies/ml but was 0.7301 for less than 5000 copies/ml. The highest plasma RNA value at which DBS RNA was not detected was 2084 copies/ml. Median (range) turnaround time from sample collection to result receipt at sites was 23 (4-69) days. The Tanzania mail service successfully transmitted all DBS and results between sites and the central laboratory. CONCLUSION Under program conditions in Tanzania, DBS provided HIV-1 RNA results comparable to conventional methods to remote healthcare facilities. DBS RNA testing is an alternative to liquid plasma for HIV-1 RNA services in remote areas.
Collapse
Affiliation(s)
- Sarah M. Lofgren
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA
| | - Anne B. Morrissey
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA
| | - Caroline C. Chevallier
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA
- Duke Global Health Institute, Duke University, Durham, North Carolina, USA
| | | | | | - Ben Amos
- Teule Hospital, Muheza, Tanzania
| | | | | | | | - Wendy S. Stevens
- Department of Molecular Medicine and Haematology, School of Pathology, Faculty of Health Sciences, University of Witwatersrand, Parktown, South Africa
- National Health Laboratory Service, Parktown, South Africa
| | - John A. Bartlett
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA
- Duke Global Health Institute, Duke University, Durham, North Carolina, USA
| | - John A. Crump
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA
- Duke Global Health Institute, Duke University, Durham, North Carolina, USA
- Kilimanjaro Christian Medical Centre, Moshi, Tanzania
- Kilimanjaro Christian Medical College, Tumaini University, Moshi, Tanzania
| |
Collapse
|
49
|
Johannessen A, Troseid M, Calmy A. Dried blood spots can expand access to virological monitoring of HIV treatment in resource-limited settings. J Antimicrob Chemother 2009; 64:1126-9. [DOI: 10.1093/jac/dkp353] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
50
|
Crump JA, Scott LE, Msuya E, Morrissey AB, Kimaro EE, Shao JF, Stevens WS. Evaluation of the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation compared with the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR v1.5 using specimens from East Africa. J Virol Methods 2009; 162:218-22. [PMID: 19729037 DOI: 10.1016/j.jviromet.2009.08.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2009] [Revised: 08/13/2009] [Accepted: 08/25/2009] [Indexed: 12/27/2022]
Abstract
The performance of the Abbott m2000rt RealTime HIV-1 assay (RealTime HIV-1) with manual sample preparation was compared against the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR Test v1.5 (CAP/CA HIV-1) using samples collected from 100 donors infected with HIV and 20 donors not infected with HIV in northern Tanzania where HIV-1 subtypes A, C, D, and their recombinant forms predominate. The RealTime HIV-1 appeared to have more within-run variability at high HIV-1 RNA concentrations, but total assay variability over the dynamic range tested was within the manufacturer's claim of <0.3 SD copies/mL. Accuracy studies showed 100% concordance for positive and negative values. When continuous values were examined, CAP/CA HIV-1 yielded higher values than the RealTime HIV-1 at higher nominal HIV-1 RNA concentrations. The RealTime HIV-1 assay showed excellent linearity between 2.5 and 7.0 log copies/mL. Of negative samples, 100% showed negative results, and >95% of samples with nominal concentrations of 40 copies/mL were detected at > or = 40 copies/mL by RealTime HIV-1. Manual sample preparation may contribute to higher total assay variability. This study suggests that the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation is an acceptable and feasible alternative to the conventional ROCHE COBAS AmpliPrep/AMLICOR HIV-1 Monitor v1.5 assay and that the RealTime HIV-1 assay performs well on samples from East Africa.
Collapse
Affiliation(s)
- John A Crump
- Division of Infectious Diseases and International Health, Department of Medicine, Duke University Medical Center, Box 102359, Durham, NC 27710, USA.
| | | | | | | | | | | | | |
Collapse
|