1
|
Robinson AD, Hill-Casey F, Duckett SB, Halse ME. Quantitative reaction monitoring using parahydrogen-enhanced benchtop NMR spectroscopy. Phys Chem Chem Phys 2024; 26:14317-14328. [PMID: 38695736 DOI: 10.1039/d3cp06221j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
The parahydrogen-induced polarisation (PHIP) NMR signal enhancement technique is used to study H2 addition to Vaska's complex (trans-[IrCl(CO)(PPh3)2]) with both standard high-field (9.4 T) NMR and benchtop (1 T) NMR detection. Accurate and repeatable rate constants of (0.84 ± 0.03) dm3 mol-1 s-1 and (0.89 ± 0.03) dm3 mol-1 s-1 were obtained for this model system using standard high-field and benchtop NMR, respectively. The high-field NMR approach is shown to be susceptible to systematic errors associated with interference from non-hyperpolarised signals, which can be overcome through a multiple-quantum filtered acquisition scheme. This challenge is avoided when using benchtop NMR detection because the non-hyperpolarised signals are much weaker due to the lower magnetic field, enabling the use of a simpler and more efficient single RF pulse detection scheme. Method validation against several experimental parameters (NMR relaxation, %pH2 enrichment and temperature) demonstrates the robustness of the benchtop NMR approach but also highlights the need for sample temperature control throughout reaction monitoring. A simple temperature equilibration protocol, coupled with use of an insulated sample holder while manipulating the sample outside the spectrometer, is found to provide sufficient temperature stabilisation to ensure that accurate and repeatable rate constants are obtained. Finally, the benchtop NMR reaction monitoring protocol is applied to the analysis of a complex mixture, where multiple reaction products form simultaneously. H2 addition to a mixture of three Vaska's complex derivatives was monitored, revealing the presence of competitive reaction pathways within the mixture.
Collapse
|
2
|
Downey K, Bermel W, Soong R, Lysak DH, Ronda K, Steiner K, Costa PM, Wolff WW, Decker V, Busse F, Goerling B, Haber A, Simpson MJ, Simpson AJ. Low-field, not low quality: 1D simplification, selective detection, and heteronuclear 2D experiments for improving low-field NMR spectroscopy of environmental and biological samples. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:345-360. [PMID: 37811556 DOI: 10.1002/mrc.5401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/15/2023] [Accepted: 09/19/2023] [Indexed: 10/10/2023]
Abstract
Understanding environmental change is challenging and requires molecular-level tools to explain the physicochemical phenomena behind complex processes. Nuclear magnetic resonance (NMR) spectroscopy is a key tool that provides information on both molecular structures and interactions but is underutilized in environmental research because standard "high-field" NMR is financially and physically inaccessible for many and can be overwhelming to those outside of disciplines that routinely use NMR. "Low-field" NMR is an accessible alternative but has reduced sensitivity and increased spectral overlap, which is especially problematic for natural, heterogeneous samples. Therefore, the goal of this study is to investigate and apply innovative experiments that could minimize these challenges and improve low-field NMR analysis of environmental and biological samples. Spectral simplification (JRES, PSYCHE, singlet-only, multiple quantum filters), selective detection (GEMSTONE, DREAMTIME), and heteronuclear (reverse and CH3/CH2/CH-only HSQCs) NMR experiments are tested on samples of increasing complexity (amino acids, spruce resin, and intact water fleas) at-high field (500 MHz) and at low-field (80 MHz). A novel experiment called Doubly Selective HSQC is also introduced, wherein 1H signals are selectively detected based on the 1H and 13C chemical shifts of 1H-13C J-coupled pairs. The most promising approaches identified are the selective techniques (namely for monitoring), and the reverse and CH3-only HSQCs. Findings ultimately demonstrate that low-field NMR holds great potential for biological and environmental research. The multitude of NMR experiments available makes NMR tailorable to nearly any research need, and low-field NMR is therefore anticipated to become a valuable and widely used analytical tool moving forward.
Collapse
Affiliation(s)
- Katelyn Downey
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | | | - Ronald Soong
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Daniel H Lysak
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Kiera Ronda
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Katrina Steiner
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Peter M Costa
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - William W Wolff
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | | | | | | | | | - Myrna J Simpson
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Andre J Simpson
- Environmental NMR Centre, University of Toronto Scarborough, Toronto, Ontario, Canada
| |
Collapse
|
3
|
Phuong J, Romero Z, Hasse H, Münnemann K. Polarization transfer methods for quantitative analysis of flowing mixtures with benchtop 13C NMR spectroscopy. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:398-411. [PMID: 38114253 DOI: 10.1002/mrc.5417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/06/2023] [Accepted: 11/09/2023] [Indexed: 12/21/2023]
Abstract
Benchtop NMR spectroscopy is attractive for process monitoring; however, there are still drawbacks that often hamper its use, namely, the comparatively low spectral resolution in 1H NMR, as well as the low signal intensities and problems with the premagnetization of flowing samples in 13C NMR. We show here that all these problems can be overcome by using 1H-13C polarization transfer methods. Two ternary test mixtures (one with overlapping peaks in the 1H NMR spectrum and one with well-separated peaks, which was used as a reference) were studied with a 1 T benchtop NMR spectrometer using the polarization transfer sequence PENDANT (polarization enhancement that is nurtured during attached nucleus testing). The mixtures were analyzed quantitatively in stationary as well as in flow experiments by PENDANT enhanced 13C NMR experiments, and the results were compared with those from the gravimetric sample preparation and from standard 1H and 13C NMR spectroscopy. Furthermore, as a proxy for a process monitoring application, continuous dilution experiments were carried out, and the composition of the mixture was monitored in a flow setup by 13C NMR benchtop spectroscopy with PENDANT. The results demonstrate the high potential of polarization transfer methods for applications in quantitative process analysis with benchtop NMR instruments, in particular with flowing samples.
Collapse
Affiliation(s)
- Johnnie Phuong
- Laboratory of Engineering Thermodynamics (LTD), RPTU Kaiserslautern, Kaiserslautern, Germany
- Laboratory of Advanced Spin Engineering - Magnetic Resonance (LASE-MR), RPTU Kaiserslautern, Kaiserslautern, Germany
| | - Zeno Romero
- Laboratory of Engineering Thermodynamics (LTD), RPTU Kaiserslautern, Kaiserslautern, Germany
- Laboratory of Advanced Spin Engineering - Magnetic Resonance (LASE-MR), RPTU Kaiserslautern, Kaiserslautern, Germany
| | - Hans Hasse
- Laboratory of Engineering Thermodynamics (LTD), RPTU Kaiserslautern, Kaiserslautern, Germany
- Laboratory of Advanced Spin Engineering - Magnetic Resonance (LASE-MR), RPTU Kaiserslautern, Kaiserslautern, Germany
| | - Kerstin Münnemann
- Laboratory of Engineering Thermodynamics (LTD), RPTU Kaiserslautern, Kaiserslautern, Germany
- Laboratory of Advanced Spin Engineering - Magnetic Resonance (LASE-MR), RPTU Kaiserslautern, Kaiserslautern, Germany
| |
Collapse
|
4
|
Zhang RY, Huang XY, Chen PX, Li T, Jiang MM, Wang YL, Zhu WX, Liu HM. A novel non-centrifugal sugar prepared from tiger nut (Cyperus esculentus L.) meal: Preparation methods and comparison with sugarcane. Food Res Int 2023; 174:113519. [PMID: 37986421 DOI: 10.1016/j.foodres.2023.113519] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 09/24/2023] [Accepted: 09/26/2023] [Indexed: 11/22/2023]
Abstract
The lack of research on the rich sucrose in tiger nut meal has been a major obstruction to the comprehensive utilization of tiger nut (Cyperus esculentus L.). In this study, for the first time, tiger nut meal was used to producing non-centrifugal sugar (NCS). Three samples - NCS-W1 (NCS prepared by water extraction and concentrated at 115 °C), NCS-W2 (NCS prepared by water extraction and concentrated at 135 °C), and NCS-E (NCS prepared by 70 % ethanol-water extraction and concentrated at 115 °C) were obtained, with yields of 14.25-14.59 %. These samples and sugarcane NCS products (NCS-C1, NCS-C2, NCS-L) were compared and analyzed in terms of color, pH, turbidity, soluble solid content, and proximate composition. Their Fourier-transformed infrared spectra, crystal patterns, and thermal stabilities were also analyzed. The NCS-W1, -W2, and -E showed excellent performance, and they were better than sugarcane NCS products in terms of free radical scavenging ability and cytoprotective effects. Differences in phenolic acid composition, flavonoid composition, amino acid, mineral content, and vitamins C and E content were also analyzed. This work demonstrates that tiger nut meal might be a new source of NCS. As such it would contribute to the full utilization of tiger nut.
Collapse
Affiliation(s)
- Run-Yang Zhang
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou 450001, China
| | - Xin-Yun Huang
- College of Food Science and Engineering & Institute of Special Oilseed Processing and Technology, Henan University of Technology, Zhengzhou 450001, China
| | - Peng-Xiao Chen
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou 450001, China
| | - Tian Li
- College of Food Science and Engineering & Institute of Special Oilseed Processing and Technology, Henan University of Technology, Zhengzhou 450001, China
| | - Meng-Meng Jiang
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou 450001, China
| | - Yi-Long Wang
- College of Food Science and Engineering & Institute of Special Oilseed Processing and Technology, Henan University of Technology, Zhengzhou 450001, China
| | - Wen-Xue Zhu
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou 450001, China.
| | - Hua-Min Liu
- College of Food Science and Engineering & Institute of Special Oilseed Processing and Technology, Henan University of Technology, Zhengzhou 450001, China.
| |
Collapse
|
5
|
Cytotoxic and antibacterial activities of compounds isolated from the fruits and stem-bark of Tetrapleura tetraptera (Schumach. & Thonn.) Taub. (Fabaceae). Med Chem Res 2022. [DOI: 10.1007/s00044-022-02956-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
6
|
Alagöz Kabakcı S, Türkyılmaz M, Özkan M. Effects of fermentation time and pH on quality of black carrot juice fermented by kefir culture during storage. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2022; 102:2563-2574. [PMID: 34687233 DOI: 10.1002/jsfa.11598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 10/01/2021] [Accepted: 10/23/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND The effects of fermentation time (17-48 h) and pH (3.37-4.50) on qualities of fermented beverages (FBs) produced from black carrot juice (BCJ) were monitored during storage at 4 °C for 20 weeks. RESULTS Fermentation and adjusting the pH level provided significant increases (up to 22%) in anthocyanin content and the absorbance value at λmax (Amax ). Moreover, the stability of anthocyanins, color density, and Amax in FBs was somewhat higher than those in BCJ. Lactic acid showed a co-pigmentation effect on cyanidin-3-galactoside-xyloside-glucoside-sinapic acid and cyanidin-3-galactoside-xyloside-glucoside-ferulic acid. Sucrose was degraded much faster at pH 4.50 (17 h) and 4.35 (48 h) than at lower pH levels. During storage, pH 4.35 caused a balanced distribution between counts of lactic acid bacteria (LAB) and yeasts, and antioxidant activity of all FBs increased. Fermented beverages at 4.35 and 3.90 were found to be more palatable by panelists. CONCLUSION We recommend FB production at pH 4.35 after 48 h fermentation due to the balanced distribution of probiotics, high color enhancement, and consumer preference. © 2021 Society of Chemical Industry.
Collapse
Affiliation(s)
- Sümeyye Alagöz Kabakcı
- Ministry of Agriculture and Forestry, National Food Reference Laboratory, Ankara, Turkey
| | | | - Mehmet Özkan
- Department of Food Engineering, Faculty of Engineering, Ankara University, Ankara, Turkey
| |
Collapse
|
7
|
Gerzon G, Sheng Y, Kirkitadze M. Process Analytical Technologies - Advances in bioprocess integration and future perspectives. J Pharm Biomed Anal 2022; 207:114379. [PMID: 34607168 DOI: 10.1016/j.jpba.2021.114379] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 09/12/2021] [Accepted: 09/15/2021] [Indexed: 12/22/2022]
Abstract
Process Analytical Technology (PAT) instruments include analyzers capable of measuring physical and chemical process parameters and key attributes with the goal of optimizing process controls. PAT in the form of a probe or sensor is designed to integrate within the pharmaceutical manufacturing line and is coupled with computing equipment to perform chemometric modeling for result interpretation and multilayer statistical control of processes. PAT solutions are intended for understanding bioprocesses with a goal to control quality at all stages of product manufacturing and achieve quality by design (QbD). The goal of PAT implementation is to promote real-time release of products to decrease the cycle time and cost of production. This review focuses on the applications of PAT solutions at different stages of the manufacturing process for vaccine production, the advantages, challenges at present state, and the vision of the future development of biopharmaceutical industries.
Collapse
Affiliation(s)
- Gabriella Gerzon
- Department of Biology, Faculty of Science, York University, Toronto, Canada; Analytical Sciences, Sanofi Pasteur, Toronto, Canada
| | - Yi Sheng
- Department of Biology, Faculty of Science, York University, Toronto, Canada
| | | |
Collapse
|
8
|
Abstract
Benchtop nuclear magnetic resonance (NMR) spectroscopy uses small permanent magnets to generate magnetic fields and therefore offers the advantages of operational simplicity and reasonable cost, presenting a viable alternative to high-field NMR spectroscopy. In particular, the use of benchtop NMR spectroscopy for rapid in-field analysis, e.g., for quality control or forensic science purposes, has attracted considerable attention. As benchtop NMR spectrometers are sufficiently compact to be operated in a fume hood, they can be efficiently used for real-time reaction and process monitoring. This review introduces the recent applications of benchtop NMR spectroscopy in diverse fields, including food science, pharmaceuticals, process and reaction monitoring, metabolomics, and polymer materials.
Collapse
|
9
|
Li D, Weng C, Ruan Y, Li K, Cai G, Song C, Lin Q. An Optical Chiral Sensor Based on Weak Measurement for the Real-Time Monitoring of Sucrose Hydrolysis. SENSORS 2021; 21:s21031003. [PMID: 33540721 PMCID: PMC7867249 DOI: 10.3390/s21031003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/22/2021] [Accepted: 01/28/2021] [Indexed: 11/16/2022]
Abstract
A chiral sensor with optical rotation detection based on weak measurement for the kinetic study of sucrose hydrolysis is presented. Based on the polarization modulation to the pre-selection state, the optical rotation of chiral sample was accurately determined through the central wavelength shift of the output spectrum. With this approach, the concentration response curves of sucrose and its hydrolysis products, i.e., fructose and glucose, were experimentally obtained for the hydrolysis analysis. By collecting the output spectrum with a frequency of 100 Hz and fitting the central wavelength shift synchronously during the measurement, the sucrose hydrolysis process was monitored in real time. Different hydrolysis conditions with varied concentration of invertase enzyme and citrate were implemented in this work. As a consequence, the real-time hydrolysis curves of the hydrolysis process with distinct velocities was achieved and analyzed. Such a kinetic monitoring about sucrose hydrolysis with optical rotation detection technology played a critical role in the researches involving sucrose, and also revealed the great potential of weak measurement in intersections, such as food safety inspection and chemical analysis.
Collapse
|
10
|
van Beek TA. Low-field benchtop NMR spectroscopy: status and prospects in natural product analysis †. PHYTOCHEMICAL ANALYSIS : PCA 2021; 32:24-37. [PMID: 31989704 DOI: 10.1002/pca.2921] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 12/14/2019] [Accepted: 12/28/2019] [Indexed: 06/10/2023]
Abstract
INTRODUCTION Since a couple of years, low-field (LF) nuclear magnetic resonance (NMR) spectrometers (40-100 MHz) have re-entered the market. They are used for various purposes including analyses of natural products. Similar to high-field instruments (300-1200 MHz), modern LF instruments can measure multiple nuclei and record two-dimensional (2D) NMR spectra. OBJECTIVE To review the commercial availability as well as applications, advantages, limitations, and prospects of LF-NMR spectrometers for the purpose of natural products analysis. METHOD Commercial LF instruments were compared. A literature search was performed for articles using and discussing modern LF-NMR. Next, the articles relevant to natural products were read and summarised. RESULTS Seventy articles were reviewed. Most appeared in 2018 and 2019. Low costs and ease of operation are most often mentioned as reasons for using LF-NMR. CONCLUSION As the spectral resolution of LF instruments is limited, they are not used for structure elucidation of new natural products but rather applied for quality control (QC), forensics, food and health research, process control and teaching. Chemometric data handling is valuable. LF-NMR is a rapidly developing niche and new instruments keep being introduced.
Collapse
Affiliation(s)
- Teris André van Beek
- Laboratory of Organic Chemistry, Wageningen University, Stippeneng 4, WE Wageningen, The Netherlands
| |
Collapse
|
11
|
Gouilleux B, Farjon J, Giraudeau P. Gradient-based pulse sequences for benchtop NMR spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106810. [PMID: 33036709 DOI: 10.1016/j.jmr.2020.106810] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/12/2020] [Accepted: 08/13/2020] [Indexed: 06/11/2023]
Abstract
Benchtop NMR spectroscopy has been on the rise for the last decade, by bringing high-resolution NMR in environments that are not easily compatible with high-field NMR. Benchtop spectrometers are accessible, low cost and show an impressive performance in terms of sensitivity with respect to the relatively low associated magnetic field (40-100 MHz). However, their application is limited by the strong and ubiquitous peak overlaps arising from the complex mixtures which are often targeted, often characterized by a great diversity of concentrations and by strong signals from non-deuterated solvents. Such limitations can be addressed by pulse sequences making clever use of magnetic field gradient pulses, capable of performing efficient coherence selection or encoding chemical shift or diffusion information. Gradients pulses are well-known ingredients of high-field pulse sequence recipes, but were only recently made available on benchtop spectrometers, thanks to the introduction of gradient coils in 2015. This article reviews the recent methodological advances making use of gradient pulses on benchtop spectrometers and the applications stemming from these developments. Particular focus is made on solvent suppression schemes, diffusion-encoded, and spatially-encoded experiments, while discussing both methodological advances and subsequent applications. We eventually discuss the exciting development and application perspectives that result from such advances.
Collapse
Affiliation(s)
- Boris Gouilleux
- Université Paris-Saclay, ICMMO, UMR CNRS 8182, RMN en Milieu Orienté, France
| | - Jonathan Farjon
- Université de Nantes, CNRS, CEISAM UMR 6230, F-44000 Nantes, France
| | - Patrick Giraudeau
- Université de Nantes, CNRS, CEISAM UMR 6230, F-44000 Nantes, France.
| |
Collapse
|
12
|
De Santis P, Meyer LE, Kara S. The rise of continuous flow biocatalysis – fundamentals, very recent developments and future perspectives. REACT CHEM ENG 2020. [DOI: 10.1039/d0re00335b] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Very recent developments in the field of biocatalysis in continuously operated systems. Special attention on the future perspectives in this key emerging technological area ranging from process analytical technologies to digitalization.
Collapse
Affiliation(s)
- Piera De Santis
- Aarhus University
- Department of Engineering, Biological and Chemical Engineering Section
- Biocatalysis and Bioprocessing Group
- DK 8000 Aarhus
- Denmark
| | - Lars-Erik Meyer
- Aarhus University
- Department of Engineering, Biological and Chemical Engineering Section
- Biocatalysis and Bioprocessing Group
- DK 8000 Aarhus
- Denmark
| | - Selin Kara
- Aarhus University
- Department of Engineering, Biological and Chemical Engineering Section
- Biocatalysis and Bioprocessing Group
- DK 8000 Aarhus
- Denmark
| |
Collapse
|