1
|
Chen X, Gao X, Yu P, Spanu L, Hinojosa J, Zhang S, Long M, Alvarez PJJ, Masiello CA. Rapid Simulation of Decade-Scale Charcoal Aging in Soil: Changes in Physicochemical Properties and Their Environmental Implications. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:128-138. [PMID: 36525597 DOI: 10.1021/acs.est.2c04751] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
In situ aging can change biochar properties, influencing their ecosystem benefits or risks over time. However, there is a lack of field verification of laboratory methods that attempt simulation of long-term natural aging of biochar. We exploited a decade-scale natural charcoal (a proxy for biochar) aging event to determine which lab-aging methods best mimicked field aging. We oxidized charcoal by ultraviolet A radiation (UVA), H2O2, or monochloramine (NH2Cl), and compared it to 10-year field-aged charcoal. We considered seven selected charcoal properties related to surface chemistry and organic matter release, and found that oxidation with 30% H2O2 most representatively simulated 10-year field aging for six out of seven properties. UVA aging failed to approximate oxidation levels while showing a distinctive dissolved organic carbon (DOC) release pattern. NH2Cl-aged charcoal was the most different, showing an increased persistent free radical (PFR) concentration and lower hydrophilicity. All lab oxidation techniques overpredicted polycyclic aromatic hydrocarbon release. The O/C ratio was well-correlated with DOC release, PFR concentration, surface charge, and charcoal pH, indicating the possibility to accurately predict biochar aging with a reduced suite of physicochemical properties. Overall, our rapid and verified lab-aging methods facilitate research toward derisking and enhancing long-term benefits of biochar application.
Collapse
Affiliation(s)
- Xiao Chen
- Department of Earth, Environmental and Planetary Sciences, Rice University, Houston, Texas 77005, United States
- Carbon Hub, Rice University, Houston, Texas 77005, United States
| | - Xiaodong Gao
- Department of Earth, Environmental and Planetary Sciences, Rice University, Houston, Texas 77005, United States
- Carbon Hub, Rice University, Houston, Texas 77005, United States
| | - Pingfeng Yu
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
| | - Leonardo Spanu
- Shell International Exploration & Production Inc., Houston, Texas 77082, United States
| | - Jessica Hinojosa
- Shell International Exploration & Production Inc., Houston, Texas 77082, United States
| | - Shuqi Zhang
- School of Environmental Science and Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai 200240, China
| | - Mingce Long
- School of Environmental Science and Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai 200240, China
| | - Pedro J J Alvarez
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
| | - Caroline A Masiello
- Department of Earth, Environmental and Planetary Sciences, Rice University, Houston, Texas 77005, United States
- Carbon Hub, Rice University, Houston, Texas 77005, United States
| |
Collapse
|
2
|
Miller S, Greenwald H, Kennedy LC, Kantor RS, Jiang R, Pisarenko A, Chen E, Nelson KL. Microbial Water Quality through a Full-Scale Advanced Wastewater Treatment Demonstration Facility. ACS ES&T ENGINEERING 2022; 2:2206-2219. [PMID: 36530600 PMCID: PMC9745798 DOI: 10.1021/acsestengg.2c00198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 06/17/2023]
Abstract
The fates of viruses, bacteria, and antibiotic resistance genes during advanced wastewater treatment are important to assess for implementation of potable reuse systems. Here, a full-scale advanced wastewater treatment demonstration facility (ozone, biological activated carbon filtration, micro/ultrafiltration, reverse osmosis, and advanced oxidation) was sampled over three months. Atypically, no disinfectant residual was applied before the microfiltration step. Microbial cell concentrations and viability were assessed via flow cytometry and adenosine triphosphate (ATP). Concentrations of bacteria (16S rRNA gene), viruses (human adenovirus and JC polyomavirus), and antibiotic resistance genes (sul1 and bla TEM ) were assessed via quantitative PCR following the concentration of large sample volumes by dead-end ultrafiltration. In all membrane filtration permeates, microbial concentrations were higher than previously reported for chloraminated membranes, and log10 reduction values were lower than expected. Concentrations of 16S rRNA and sul1 genes were reduced by treatment but remained quantifiable in reverse osmosis permeate. It is unclear whether sul1 in the RO permeate was from the passage of resistance genes or new growth of microorganisms, but the concentrations were on the low end of those reported for conventional drinking water distribution systems. Adenovirus, JC polyomavirus, and bla TEM genes were reduced below the limit of detection (∼10-2 gene copies per mL) by microfiltration. The results provide insights into how treatment train design and operation choices affect microbial water quality as well as the use of flow cytometry and ATP for online monitoring and process control.
Collapse
Affiliation(s)
- Scott Miller
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
| | - Hannah Greenwald
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
| | - Lauren C. Kennedy
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
- Department
of Civil and Environmental Engineering, College of Engineering, Stanford University, Stanford, California 94305, United States
| | - Rose S. Kantor
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
| | - Renjing Jiang
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
| | - Aleksey Pisarenko
- Trussell
Technologies, Inc., Solana
Beach, California 92075, United States
| | - Elise Chen
- Trussell
Technologies, Inc., Solana
Beach, California 92075, United States
| | - Kara L. Nelson
- Department
of Civil and Environmental Engineering, College of Engineering, University of California, Berkeley, Berkeley, California 94720, United States
- National
Science Foundation Engineering Research Center for Re-inventing the
Nation’s Urban Water Infrastructure (ReNUWIt), Berkeley, California 94720, United States
| |
Collapse
|
3
|
A deep neural networks framework for in-situ biofilm thickness detection and hydrodynamics tracing for filtration systems. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
4
|
Cheng W, Wang P, Zhang Y, Wang H, Ma J, Zhang T. Oxidation resistances of polyamide nanofiltration membranes to hydroxyl and sulfate radicals. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.121156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Wang HB, Wu YH, Wang WL, Chen Z, Chen GQ, Luo LW, Xue S, Tong X, Zhang ZW, Ikuno N, Ishii K, Hu HY. Comparison of disinfection-residual-bacteria (DRB) after seven different kinds of disinfection: Biofilm formation, membrane fouling and mechanisms. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:157079. [PMID: 35779720 DOI: 10.1016/j.scitotenv.2022.157079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/16/2022] [Accepted: 06/27/2022] [Indexed: 06/15/2023]
Abstract
Membrane fouling is the Achilles' heel of the reverse osmosis (RO) system for high-quality reclaimed water production. Previous studies have found that after the significant selection effect of traditional disinfection, the remaining disinfection-residual bacteria (DRB) may possess more severe biofouling potentials. To provide more constructive advice for the prevention of biofouling, we compared the RO membrane fouling characteristics of DRB after using five commonly used disinfection methods (NaClO, NH2Cl, ClO2, UV, and O3) and two novel disinfection methods (K2FeO4 and the flow-through electrode system (FES)). Compared with the control group (undisinfected, 21.1 % flux drop), the UV-DRB biofilm aggravated biofouling of the RO membrane (23.4 % flux drop), while the FES, K2FeO4, and NH2Cl treatments showed less severe biofouling, with final flux drops of 6.9 %, 8.1 %, and 8.1 %, respectively. Adenosine triphosphate (ATP) was found to be a capable indicator for predicting the biofouling potential of DRB. Systematic analysis showed that the thickness and density of the DRB biofilms were most closely related to the different fouling degree of RO membranes. Moreover, the relative abundance of bacteria with higher extracellular polymeric substance (EPS) secretion levels, such as Pseudomonas and Sphingomonas, was found closely related with the biofouling degree of RO membranes.
Collapse
Affiliation(s)
- Hao-Bin Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China.
| | - Wen-Long Wang
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Gen-Qiang Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Li-Wei Luo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Song Xue
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Xin Tong
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Zi-Wei Zhang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Nozomu Ikuno
- Kurita Water Industries Ltd., Nakano-ku, Tokyo 164-0001, Japan
| | - Kazuki Ishii
- Kurita Water Industries Ltd., Nakano-ku, Tokyo 164-0001, Japan
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Jiangsu, Suzhou 215163, PR China
| |
Collapse
|
6
|
Wu L, Patton SD, Liu H. Mechanisms of oxidative removal of 1,4-dioxane via free chlorine rapidly mixing into monochloramine: Implications on water treatment and reuse. JOURNAL OF HAZARDOUS MATERIALS 2022; 440:129760. [PMID: 35969953 DOI: 10.1016/j.jhazmat.2022.129760] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/04/2022] [Accepted: 08/09/2022] [Indexed: 06/15/2023]
Abstract
Free chlorine (HOCl) and monochloramine (NH2Cl) are two of the most commonly used water disinfectants in water treatment; however, the capability of rapid mixing of HOCl into NH2Cl to induce oxidative reactions for efficient removal of contaminants remains largely unknown. In this study, 1,4-dioxane (1,4-D) removal was quantified during the rapid mixing of HOCl into NH2Cl, to evaluate the effects of solution pH and HOCl-to-NH2Cl ratio, and to identify mechanisms by which reactive species are generated in the system. Results showed that the highest 1,4-D removal was observed at the near-neutral pH of 6 with the HOCl-to-NH2Cl molar ratio of 1. Hydroxyl radical (HO•) contributed to 60-70 % of 1,4-D degradation and its generation was initiated by the hydrolytic decay of NH2Cl and NHCl2 upon HOCl addition to NH2Cl with rapid mixing, and subsequent transformation of peroxynitrite (ONOO-) and peroxynitrous acid (ONOOH). The results also confirmed that the presence of dissolved oxygen was required to form ONOO-/ONOOH, and ONOO- was a crucial precursor for reactive radical generation. These findings provide insight into the reaction mechanism associated with the system of rapidly mixed HOCl into NH2Cl with the potential optimization and application for efficient trace organics removal in water treatment and reuse.
Collapse
Affiliation(s)
- Liang Wu
- Environmental Toxicology Program, University of California, Riverside, CA 92521, USA; Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, USA
| | - Samuel D Patton
- Environmental Toxicology Program, University of California, Riverside, CA 92521, USA; Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, USA
| | - Haizhou Liu
- Environmental Toxicology Program, University of California, Riverside, CA 92521, USA; Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, USA.
| |
Collapse
|
7
|
Farhat N, Kim L, Mineta K, Alarawi M, Gojobori T, Saikaly P, Vrouwenvelder J. Seawater desalination based drinking water: Microbial characterization during distribution with and without residual chlorine. WATER RESEARCH 2022; 210:117975. [PMID: 34952456 DOI: 10.1016/j.watres.2021.117975] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 12/12/2021] [Accepted: 12/14/2021] [Indexed: 06/14/2023]
Abstract
Monitoring the changes that occur to water during distribution is vital to ensure water safety. In this study, the biological stability of reverse osmosis (RO) produced drinking water, characterized by low cell concentration and low assimilable organic carbon, in combination with chlorine disinfection was investigated. Water quality at several locations throughout the existing distribution network was monitored to investigate whether microbial water quality changes can be identified. Results revealed that the water leaving the plant had an average bacterial cell concentration of 103 cells/mL. A 0.5-1.5 log increase in bacterial cell concentration was observed at locations in the network. The residual disinfectant was largely dissipated in the network from 0.5 mg/L at the treatment plant to less than 0.1 mg/L in the network locations. The simulative study involving miniature distribution networks, mimicking the dynamics of a distribution network, fed with the RO produced chlorinated and non-chlorinated drinking water revealed that distributing RO produced water without residual disinfection, especially at high water temperatures (25-30 °C), poses a higher chance for water quality change. Within six months of operation of the miniature network fed with unchlorinated RO produced water, the adenosine triphosphate (ATP) and total cell concentration (TCC) in the pipe biofilm were 4 × 102 pg ATP/cm2 and 1 × 107 cells/ cm2. The low bacterial cell concentration and organic carbon concentration in the RO-produced water did not prevent biofilm development inside the network with and without residual chlorine. The bacterial community analysis using 16S ribosomal RNA (rRNA) gene sequencing revealed that mesophilic bacteria with higher temperature tolerance and bacteria associated with oligotrophic, nutrient-poor conditions dominated the biofilm, with no indication of the existence of opportunistic pathogenic species. However, chlorination selected against most bacterial groups and the bacterial community that remained was mainly the bacteria capable of surviving disinfection regimes. Biofilms that developed in the presence of chlorine contained species classified as opportunistic pathogens. These biofilms have an impact on shaping the water quality received at the consumer tap. The presence of these bacteria on its own is not a health risk indicator; viability assessment and qPCRs targeting genes specific to the opportunistic pathogens as well as quantitative microbiological risk assessment (QMRA) should be included to assess the risk. The results from this study highlight the importance of implementing multiple barriers to ensure water safety. Changes in water quality detected even when high-quality disinfected RO-produced water is distributed highlight microbiological challenges that chlorinated systems endure, especially at high water temperatures.
Collapse
Affiliation(s)
- Nadia Farhat
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| | - Lanhee Kim
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Katsuhiko Mineta
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Mohammed Alarawi
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Takashi Gojobori
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Pascal Saikaly
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Johannes Vrouwenvelder
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Faculty of Applied Sciences, Department of Biotechnology, Delft University of Technology, Van der Maasweg 9, Delft 2629 HZ, Netherlands
| |
Collapse
|
8
|
Effect of halides on polyamide-based membrane flux and monomer degradation during chloramination. J Memb Sci 2021. [DOI: 10.1016/j.memsci.2021.119717] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
9
|
Kerdi S, Qamar A, Vrouwenvelder JS, Ghaffour N. Biofilm removal efficacy using direct electric current in cross-flow ultrafiltration processes for water treatment. J Memb Sci 2021. [DOI: 10.1016/j.memsci.2020.118808] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Maganha de Almeida Kumlien AC, Borrego CM, Balcázar JL. Antimicrobial Resistance and Bacteriophages: An Overlooked Intersection in Water Disinfection. Trends Microbiol 2021; 29:517-527. [PMID: 33500192 DOI: 10.1016/j.tim.2020.12.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 12/17/2020] [Accepted: 12/24/2020] [Indexed: 12/23/2022]
Abstract
This article focuses on how bacteriophages (phages), antibiotic-resistance genes (ARGs), and disinfection practices intersect. Phages are considered to be the most abundant biological entities on Earth and they have the potential to transfer genes (including ARGs) among their bacterial hosts. In the urban water cycle, phages are used as indicators of fecal pollution and surrogates for human viral pathogens but they are also known to withstand common disinfection treatments deployed to produce safe drinking/reclaimed water. Recent studies also suggest that phages have the potential to become an additional footprint to monitor water safety. A precautionary approach should therefore include phages in surveillance programs aimed at monitoring antimicrobial resistance (AMR) in the urban water cycle. This article argues that phages ought to be used to assess the efficiency of disinfection treatments (both classical and novel) on reducing the risk associated with antibiotic resistance. Finally, this article discusses contributions to the advancement of AMR stewardship in aquatic settings and is relevant for researchers and water industry practitioners.
Collapse
Affiliation(s)
| | - Carles M Borrego
- Catalan Institute for Water Research (ICRA), 17003 Girona, Spain; Group of Molecular Microbial Ecology, Institute of Aquatic Ecology, University of Girona, 17003 Girona, Spain
| | - José Luis Balcázar
- Catalan Institute for Water Research (ICRA), 17003 Girona, Spain; University of Girona, 17004 Girona, Spain
| |
Collapse
|
11
|
Hashiba K, Nakai S, Nishijima W, Ohno M, Gotoh T. Degradation of secondary polyamide reverse osmosis membrane by hypochlorite in the presence of calcium ions. Polym Degrad Stab 2020. [DOI: 10.1016/j.polymdegradstab.2020.109351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
12
|
Fujioka T, Tra Ngo MT, Mochochoko T, Boivin S, Ohkuma N, Yasui H, Terashima M. Biofouling control of a forward osmosis membrane during single-pass pre-concentration of wastewater. CHEMOSPHERE 2020; 257:127263. [PMID: 32512337 DOI: 10.1016/j.chemosphere.2020.127263] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/27/2020] [Accepted: 05/29/2020] [Indexed: 06/11/2023]
Abstract
Pre-concentration of wastewater using a forward osmosis (FO) membrane prior to processing by an anaerobic digester can enhance biogas production. However, biofouling caused by microbes in wastewater remains a challenge. The study aimed to evaluate the efficacy of chloramination in mitigating the biofouling of an FO membrane during a single-pass concentration of primary wastewater effluent. Pre-disinfection at a chloramine dose of 22-121 mg/L successfully alleviated membrane fouling. Bacterial cell counts in the feed and concentrate showed that most of the bacterial cells in the wastewater were trapped on the membrane surface or spacer. The FO membrane surfaces in non-chloraminated/chloraminated systems were fully-covered by intact/damaged bacterial cells, respectively, indicating that chloramination effectively mitigated biofouling. However, due to high permeate-recovery and low cross-flow velocity in a single-pass concentration process, organic fouling on the membrane surface (and possibly on the interior wall of the membrane-pores) appeared to cause a gradual reduction in permeate-flux. This study demonstrated successful biofouling control using chloramination during a single-pass and high-recovery pre-concentration of primary wastewater effluent.
Collapse
Affiliation(s)
- Takahiro Fujioka
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan.
| | - My Thi Tra Ngo
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Tanki Mochochoko
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Sandrine Boivin
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Naoki Ohkuma
- Water Reuse Promotion Center, 4-5 Nihonbashiyokoyamacho, Tokyo, 103-0003, Japan
| | - Hidenari Yasui
- Faculty of Environmental Engineering, The University of Kitakyushu, 1-1 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| | - Mitsuharu Terashima
- Faculty of Environmental Engineering, The University of Kitakyushu, 1-1 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| |
Collapse
|
13
|
Pinel ISM, Kim LH, Proença Borges VR, Farhat NM, Witkamp GJ, van Loosdrecht MCM, Vrouwenvelder JS. Effect of phosphate availability on biofilm formation in cooling towers. BIOFOULING 2020; 36:800-815. [PMID: 32883093 DOI: 10.1080/08927014.2020.1815011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/20/2020] [Accepted: 08/20/2020] [Indexed: 06/11/2023]
Abstract
Phosphate limitation has been suggested as a preventive method against biofilms. P-limited feed water was studied as a preventive strategy against biofouling in cooling towers (CTs). Three pilot-scale open recirculating CTs were operated in parallel for five weeks. RO permeate was fed to the CTs (1) without supplementation (reference), (2) with supplementation by biodegradable carbon (P-limited) and (3) with supplementation of all nutrients (non-P-limited). The P-limited water contained ≤10 µg PO4 l-1. Investigating the CT-basins and coupons showed that P-limited water (1) did not prevent biofilm formation and (2) resulted in a higher volume of organic matter per unit of active biomass compared with the other CTs. Exposure to external conditions and cycle of concentration were likely factors that allowed a P concentration sufficient to cause extensive biofouling despite being the limiting compound. In conclusion, phosphate limitation in cooling water is not a suitable strategy for CT biofouling control.
Collapse
Affiliation(s)
- Ingrid S M Pinel
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Lan Hee Kim
- Division of Biological and Environmental Science and Engineering (BESE), Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
| | - Vitor R Proença Borges
- Division of Biological and Environmental Science and Engineering (BESE), Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
| | - Nadia M Farhat
- Division of Biological and Environmental Science and Engineering (BESE), Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
| | - Geert-Jan Witkamp
- Division of Biological and Environmental Science and Engineering (BESE), Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
| | - Mark C M van Loosdrecht
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Johannes S Vrouwenvelder
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
- Division of Biological and Environmental Science and Engineering (BESE), Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
| |
Collapse
|
14
|
Fujioka T, Yoshikawa H, Eguchi M, Boivin S, Kodamatani H. Application of stabilized hypobromite for controlling membrane fouling and N-nitrosodimethylamine formation. CHEMOSPHERE 2020; 240:124939. [PMID: 31726604 DOI: 10.1016/j.chemosphere.2019.124939] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 09/19/2019] [Accepted: 09/21/2019] [Indexed: 06/10/2023]
Abstract
Chloramination is a conventional and successful pre-disinfection approach to control biological fouling for reverse osmosis (RO) treatment in water reuse. This study aimed to evaluate the possibility of using a new disinfectant-stabilized hypobromite-in controlling membrane fouling and the formation of a particular carcinogenic disinfection byproduct (DBP)-N-nitrosodimethylamine (NDMA). Our accelerated chemical exposure tests showed that the new disinfectant reduced the permeability of a polyamide RO membrane permeability from 6.7 to 4.1 L/m2hbar; however, its treatment impact was equivalent to that of chloramine. The disinfection efficacy of stabilized hypobromite was greater than that of chloramine when evaluated with intact bacterial counts, which suggests its potential for mitigating membrane biofouling. Additional pilot-scale tests using synthetic wastewater demonstrated that pre-disinfection with the use of stabilized hypobromite inhibits membrane fouling. Among 13 halogenated DBPs evaluated, the formation of bromoform by stabilized hypobromite was higher than that by chloramine at a high dose of 10 mg/L, thus suggesting the need for optimizing chemical doses for achieving sufficient biofouling mitigation. NDMA formation upon stabilized hypobromite treatment in two different types of actual treated wastewaters was found to be negligible and considerably lower than that by chloramine treatment. In addition, NDMA formation potential by stabilized hypobromite was 2-5 orders of magnitude lower than that by chloramine. Our findings suggest the potential of using stabilized hypobromite for controlling NDMA formation and biofouling, which are the keys to successful potable water reuse.
Collapse
Affiliation(s)
- Takahiro Fujioka
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan.
| | - Hiro Yoshikawa
- R&D Center, Organo Corporation, 4-4-1 Nishionuma Minamiku, Sagamihara, 252-0332, Japan
| | - Masahiro Eguchi
- R&D Center, Organo Corporation, 4-4-1 Nishionuma Minamiku, Sagamihara, 252-0332, Japan
| | - Sandrine Boivin
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Hitoshi Kodamatani
- Division of Earth and Environmental Science, Graduate School of Science and Engineering, Kagoshima University, 1-21-35 Korimoto, Kagoshima, 890-0065, Japan
| |
Collapse
|
15
|
Sacher F, Gerstner P, Merklinger M, Thoma A, Kinani A, Roumiguières A, Bouchonnet S, Richard-Tanaka B, Layousse S, Ata R, Marolleau F, Kinani S. Determination of monochloramine dissipation kinetics in various surface water qualities under relevant environmental conditions - Consequences regarding environmental risk assessment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 685:542-554. [PMID: 31181531 DOI: 10.1016/j.scitotenv.2019.05.364] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/23/2019] [Accepted: 05/23/2019] [Indexed: 06/09/2023]
Abstract
A total 190 experiments were performed to study the dissipation kinetics of monochloramine (NH2Cl, CAS no 10599-90-3) in surface water samples from six rivers (Loire, Rhône, Meuse, Garonne, Seine and Moselle) and an artificial reservoir (Mirgenbach), all located in France. Experiments were conducted in an open reactor, under relevant controlled environmental conditions. The impact of various parameters such as initial NH2Cl concentration, temperature, pH, presence of sediments, sampling site and collection period was investigated. It was found that NH2Cl dissipated rapidly without any lag phase, and that decay follows an apparent first-order kinetics (r2 > 0.99). Presence of sediment greatly accelerated decay. Half-lives were generally <1 h in river water in presence of natural sediment, but of several hours without sediment. The impact of pH was low for the normal river water pH range. However, increase in temperature significantly accelerated decay. The combination of high initial NH2Cl concentrations and elevated temperatures generally gives half-lives similar to those obtained at lower temperatures and lower concentrations. Short half-lives (0.06 to 1.50 h) were found in all the surface waters examined, regardless of geographic location of sampling site or collection period, indicating no temporal or site-specific effects on NH2Cl dissipation. Decay was slightly faster at lower initial concentrations, which supports extrapolation of half-lives measured in this study to a wide range of environmental concentrations. It can thus be assumed that NH2Cl degradation in river and reservoir waters is mainly determined by presence of sediments and temperature.
Collapse
Affiliation(s)
- Frank Sacher
- DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany.
| | - Pia Gerstner
- DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany
| | - Michael Merklinger
- DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany
| | - Astrid Thoma
- DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany
| | - Aziz Kinani
- LCM, CNRS - École Polytechnique, Université Paris Saclay, Route de Saclay, 91128 Palaiseau, France; EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France
| | - Adrien Roumiguières
- LCM, CNRS - École Polytechnique, Université Paris Saclay, Route de Saclay, 91128 Palaiseau, France; EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France
| | - Stéphane Bouchonnet
- LCM, CNRS - École Polytechnique, Université Paris Saclay, Route de Saclay, 91128 Palaiseau, France.
| | - Bertille Richard-Tanaka
- EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France
| | - Stephany Layousse
- EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France
| | - Riadh Ata
- EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France
| | - Franck Marolleau
- EDF DIPDE - Division de l'Ingénierie du Parc, de la Déconstruction & de l'Environnement, 154 avenue Thiers, 69458 Lyon Cedex 06, France.
| | - Said Kinani
- EDF R&D LNHE - Laboratoire National d'Hydraulique et Environnement, 6 Quai Watier, 78401 Chatou Cedex 01, France.
| |
Collapse
|
16
|
Pilot-Scale Assessment of Urea as a Chemical Cleaning Agent for Biofouling Control in Spiral-Wound Reverse Osmosis Membrane Elements. MEMBRANES 2019; 9:membranes9090117. [PMID: 31500149 PMCID: PMC6780893 DOI: 10.3390/membranes9090117] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 08/26/2019] [Accepted: 08/28/2019] [Indexed: 11/18/2022]
Abstract
Routine chemical cleaning with the combined use of sodium hydroxide (NaOH) and hydrochloric acid (HCl) is carried out as a means of biofouling control in reverse osmosis (RO) membranes. The novelty of the research presented herein is in the application of urea, instead of NaOH, as a chemical cleaning agent to full-scale spiral-wound RO membrane elements. A comparative study was carried out at a pilot-scale facility at the Evides Industriewater DECO water treatment plant in the Netherlands. Three fouled 8-inch diameter membrane modules were harvested from the lead position of one of the full-scale RO units treating membrane bioreactor (MBR) permeate. One membrane module was not cleaned and was assessed as the control. The second membrane module was cleaned by the standard alkali/acid cleaning protocol. The third membrane module was cleaned with concentrated urea solution followed by acid rinse. The results showed that urea cleaning is as effective as the conventional chemical cleaning with regards to restoring the normalized feed channel pressure drop, and more effective in terms of (i) improving membrane permeability, and (ii) solubilizing organic foulants and the subsequent removal of the surface fouling layer. Higher biomass removal by urea cleaning was also indicated by the fact that the total organic carbon (TOC) content in the HCl rinse solution post-urea-cleaning was an order of magnitude greater than in the HCl rinse after standard cleaning. Further optimization of urea-based membrane cleaning protocols and urea recovery and/or waste treatment methods is proposed for full-scale applications.
Collapse
|
17
|
Biofouling Mitigation by Chloramination during Forward Osmosis Filtration of Wastewater. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15102124. [PMID: 30261685 PMCID: PMC6210331 DOI: 10.3390/ijerph15102124] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 09/15/2018] [Accepted: 09/24/2018] [Indexed: 11/16/2022]
Abstract
Pre-concentration is essential for energy and resource recovery from municipal wastewater. The potential of forward osmosis (FO) membranes to pre-concentrate wastewater for subsequent biogas production has been demonstrated, although biofouling has also emerged as a prominent challenge. This study, using a cellulose triacetate FO membrane, shows that chloramination of wastewater in the feed solution at 3⁻8 mg/L residual monochloramine significantly reduces membrane biofouling. During a 96-h pre-concentration, flux in the chloraminated FO system decreased by only 6% and this flux decline is mostly attributed to the increase in salinity (or osmotic pressure) of the feed due to pre-concentration. In contrast, flux in the non-chloraminated FO system dropped by 35% under the same experimental conditions. When the feed was chloraminated, the number of bacterial particles deposited on the membrane surface was significantly lower compared to a non-chloraminated wastewater feed. This study demonstrated, for the first time, the potential of chloramination to inhibit bacteria growth and consequently biofouling during pre-concentration of wastewater using a FO membrane.
Collapse
|