1
|
Lanjwani MF, Tuzen M, Khuhawar MY, Afshar Mogaddam MR, Farajzadeh MA. Deep Eutectic Solvents for Extraction and Preconcentration of Organic and Inorganic Species in Water and Food Samples: A Review. Crit Rev Anal Chem 2024; 54:1290-1303. [PMID: 35980662 DOI: 10.1080/10408347.2022.2111655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Deep eutectic solvents (DESs) have been developed as green solvents and these are capable as alternatives to conventional solvents used for the extraction of organic and inorganic species from food and water samples. The continuous generation of contaminated waste and increasing concern for the human health and environment have compelled the scientific community to investigate more ecological schemes. In this concern, the use of DESs have developed in one of the chief approach in the field of chemistry. These solvents have appeared as a capable substitute to conventional hazardous solvents and ionic liquids. The DESs has distinctive properties, easy preparation and components availability. It is not only used in scienctific fields but also used in quotidian life. There are many advantages of DESs in analytical chemistry, they are largely used for extraction and determination of inorganic and organic compounds from different samples. In previous a few years, several advanced researches have been focused on the separation and preconcentration of low level of pollutants using DESs as the extractants. This review summarizes the use of DESs in the separation and preconcentration of organic and inorganic species from water and food samples using various microextraction processes.
Collapse
Affiliation(s)
- Muhammad Farooque Lanjwani
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpasa University, Tokat, Turkey
- Dr M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Sindh, Pakistan
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpasa University, Tokat, Turkey
- King Fahd University of Petroleum and Minerals, Research Institute, Center for Environment and Marine Studies, Dhahran, Saudi Arabia
| | - Muhammad Yar Khuhawar
- Institute of Advanced Research Studies in Chemical Sciences, University of Sindh, Jamshoro, Sindh, Pakistan
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
2
|
Gupta A, Rotake D, Darji A. Sensing lead ions in water: a comprehensive review on strategies and sensor materials. ANAL SCI 2024; 40:997-1021. [PMID: 38523231 DOI: 10.1007/s44211-024-00547-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 02/25/2024] [Indexed: 03/26/2024]
Abstract
It is well-known fact that elevated lead ions (Pb2+), the third most toxic among heavy metal ions in aqueous systems, pose a threat to human health and aquatic ecosystems when they exceed permissible limits. Pb2+ is commonly found in industrial waste and fertilizers, contaminating water sources and subsequently entering the human body, causing various adverse health conditions. Unlike being expelled, Pb2+ accumulates within the body, posing potential health risks. The harmful impact of presence of Pb2+ in water have prompted researchers to diligently work toward maintaining water quality. Recognizing the importance of Pb2+, this review article makes a sincere and effective effort to address the issues associated with Pb2+. This overview article gives insights into various sensing approaches to detect Pb2+ in water using different sensing materials, including 2-dimensional materials, thiols, quantum dots, and polymers. Herein, different sensing approaches such as electrochemical, optical, field effect transistor-based, micro-electromechanical system-based, and chemi resistive are thoroughly explained. Field effect transistor-based and chemiresistive work on similar principles and are compared on the basis of their fabrication processes and sensing capabilities. In conclusion, future directions for chemiresistive sensors in Pb2+ detection are proposed, emphasizing their simplicity, portability, straightforward functionality, and ease of fabrication. Notably, it sheds light on various thiol and ligand compounds and coupling strategies utilized in Pb2+ detection. This comprehensive study is expected to benefit individuals engaged in Pb2+ detection.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
- Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Ramdeo Tekdi, Nagpur, 440013, Maharashtra, India
| | - Dinesh Rotake
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Hyderabad, 502284, Telangana, India.
| | - Anand Darji
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
| |
Collapse
|
3
|
Luján CE, Lemos AA, Oviedo MN, Llaver M, Wuilloud RG. Deep eutectic solvents as a green alternative for trace element analysis in food and beverage samples: Recent advances and challenges. Talanta 2024; 269:125451. [PMID: 38048680 DOI: 10.1016/j.talanta.2023.125451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 11/17/2023] [Accepted: 11/20/2023] [Indexed: 12/06/2023]
Abstract
Metals and metalloids have different effects on human health even at trace levels. Some of them are essential for living organisms while others can be toxic. Therefore, the determination of trace elements in food and beverage is highly important to understand their impact in human health. A new generation of solvents named deep eutectic solvents (DES) has emerged as a green alternative for trace element analysis, owing to their low toxicity, biodegradability, and high extraction capacity. In recent years, the application of DES in extraction techniques for trace element analysis in food and beverage samples has increased significantly. This review summarizes recent advances and challenges on the application of DES to develop microextraction techniques useful for the analysis of samples with complex matrices. The importance of the use of biodegradable substances instead of classic organic solvents, which are toxic, volatile, and flammable in methods for elemental analysis with a positive environmental impact is also highlighted. Finally, conclusions and future challenges arising from the use of DES in microextraction techniques are discussed.
Collapse
Affiliation(s)
- Cecilia E Luján
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Aldana A Lemos
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - María N Oviedo
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Mauricio Llaver
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina
| | - Rodolfo G Wuilloud
- Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo/Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, (5500) Mendoza, Argentina.
| |
Collapse
|
4
|
Chormey DS, Zaman BT, Kustanto TB, Erarpat Bodur S, Bodur S, Er EÖ, Bakırdere S. Deep eutectic solvents for the determination of endocrine disrupting chemicals. Talanta 2024; 268:125340. [PMID: 37948953 DOI: 10.1016/j.talanta.2023.125340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 10/18/2023] [Accepted: 10/23/2023] [Indexed: 11/12/2023]
Abstract
The harmful effects of endocrine disrupting chemicals (EDCs) to humans and other organisms in the environment have been well established over the years, and more studies are ongoing to classify other chemicals that have the potential to alter or disrupt the regular function of the endocrine system. In addition to toxicological studies, analytical detection systems are progressively being improved to facilitate accurate determination of EDCs in biological, environmental and food samples. Recent microextraction methods have focused on the use of green chemicals that are safe for analytical applications, and present very low or no toxicity upon disposal. Deep eutectic solvents (DESs) have emerged as one of the viable alternatives to the conventional hazardous solvents, and their unique properties make them very useful in different applications. Notably, the use of renewable sources to prepare DESs leads to highly biodegradable products that mitigate negative ecological impacts. This review presents an overview of both organic and inorganic EDCs and their ramifications on human health. It also presents the fundamental principles of liquid phase and solid phase microextraction methods, and gives a comprehensive account of the use of DESs for the determination of EDCs in various samples.
Collapse
Affiliation(s)
- Dotse Selali Chormey
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Turkiye.
| | - Buse Tuğba Zaman
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye
| | - Tülay Borahan Kustanto
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Turkiye
| | - Sezin Erarpat Bodur
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye
| | - Süleyman Bodur
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34010, İstanbul, Turkiye; İstinye University, Scientific and Technological Research Application and Research Center, 34010, İstanbul, Turkiye
| | - Elif Özturk Er
- İstanbul Technical University, Department of Chemical Engineering, 34469, İstanbul, Turkiye
| | - Sezgin Bakırdere
- Yıldız Technical University, Department of Chemistry, 34220, İstanbul, Turkiye; Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Çankaya, 06670, Ankara, Turkiye.
| |
Collapse
|
5
|
Nguyen V, Linh TTT, Vo T, Nguyen QH, Van T. Analytical techniques for determination of heavy metal migration from different types of locally made plastic food packaging materials using ICP-MS. Food Sci Nutr 2023; 11:4030-4037. [PMID: 37457188 PMCID: PMC10345700 DOI: 10.1002/fsn3.3391] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 03/15/2023] [Accepted: 04/06/2023] [Indexed: 07/18/2023] Open
Abstract
Plastic food packaging is an essential element for customer convenience and the preservation of food quality. Nonetheless, heavy metals in the packaging materials, either intentionally or nonintentionally added, can be transferred to the food. Therefore, determining heavy metal contents in these packaging materials is essential. In this study, heavy metals, including Co, Ge, As, Cd, Sb, Pb, Al, and Zn from different intrinsic plastic food packaging materials were analyzed using the inductively coupled plasma-mass spectrometry (ICP-MS) method. Moreover, the migration of these elements into the environment was also investigated. This method is validated following the new technique's requirements, which include linearity range, accuracy, precision, the limit of detection (LOD), and the limit of quantitation (LOQ). The method has been suitably validated with the regression equation from the standards prepared in HNO3 1% v/v. The linear range was found to be ~1-20 ng mL-1 for Co, Ge, As, Cd, Sb, and Pb and 5-80 ng mL-1 for Al and Zn elements. The LODs are ~0.10, 0.25, 0.12, 0.13, 0.11, 0.12, 0.61, and 0.85 ng mL-1, and the LOQs are 0.33, 0.83, 0.40, 0.43, 0.36, 0.40, 2.01, and 2.81 ng mL-1 obtained for Co, Ge, As, Cd, Sb, Pb, Al, and Zn, respectively. In addition, the recovery percentages received ranged 85.4%-94.1% for Co, 82.6%-95.1% for Ge, 86.3%-97.9% for As, 87.3%-96.3% for Cd, 88.0%-104.4% for Sb, 96.3%-106.0% for Pb, 88.4%-104.0% for Al, and 95.1%-99.7% for Zn. Finally, the migration of these heavy metals from polypropylene (PP) and polystyrene (PS) into foodstuffs was also simulated according to EU legislation, showing that the most leached element was Zn, followed by Al and Pd, with the migration of ~8.38% and ~0.41%, and ~0.19%, respectively.
Collapse
Affiliation(s)
- Van‐Trong Nguyen
- Faculty of Chemical EngineeringIndustrial University of Ho Chi Minh CityHo Chi Minh CityVietnam
| | - Truong Thi Truc Linh
- Faculty of Chemical EngineeringIndustrial University of Ho Chi Minh CityHo Chi Minh CityVietnam
- Center of Analytical Services and Experimentation HCMCHo Chi Minh CityVietnam
| | - The‐Ky Vo
- Faculty of Chemical EngineeringIndustrial University of Ho Chi Minh CityHo Chi Minh CityVietnam
| | - Quoc Hung Nguyen
- Center of Analytical Services and Experimentation HCMCHo Chi Minh CityVietnam
| | - Thanh‐Khue Van
- Faculty of Chemical EngineeringIndustrial University of Ho Chi Minh CityHo Chi Minh CityVietnam
| |
Collapse
|
6
|
Wu D, Hu Y, Cheng H, Ye X. Detection Techniques for Lead Ions in Water: A Review. Molecules 2023; 28:molecules28083601. [PMID: 37110841 PMCID: PMC10143718 DOI: 10.3390/molecules28083601] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/07/2023] [Accepted: 04/14/2023] [Indexed: 04/29/2023] Open
Abstract
Lead pollution has increasingly become the focus of environmental pollution, which is a great harm to the ecological environment and human health. Strict control of the emission of lead pollutants and accurate monitoring of lead are very important. The lead ion detection technologies are introduced here, including spectrophotometry, electrochemical method, atomic absorption spectrometry, and other detection methods, and the methods' applicability, the advantages, and disadvantages are discussed. The detection limits of voltammetry and atomic absorption spectrometry are as low as 0.1 μg/L, and those of atomic absorption spectrometry are as low as 2 μg/L. The detection limit of photometry is higher (0.01 mg/L), but this method can be achieved in most laboratories. The application of different extraction pretreatment technologies in lead ion detection is introduced. The new technologies develop at home and abroad, such as precious metal nanogold technology, paper microfluidic technology, fluorescence molecular probe technology, spectroscopy, and other emerging technologies in recent years, are reviewed, and the principle and application of various technologies are expounded.
Collapse
Affiliation(s)
- Dan Wu
- National-Local Joint Engineering Laboratory of Intelligent Food Technology and Equipment, Zhejiang Key Laboratory for Agro-Food Processing, Integrated Research Base of Southern Fruit and Vegetable Preservation Technology, Zhejiang International Scientific and Technological Cooperation Base of Health Food Manufacturing and Quality Control, Fuli Institute of Food Science, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Yinglu Hu
- Zhejiang Lohand Environmental Technology Co., Ltd., Hangzhou 310018, China
| | - Huan Cheng
- National-Local Joint Engineering Laboratory of Intelligent Food Technology and Equipment, Zhejiang Key Laboratory for Agro-Food Processing, Integrated Research Base of Southern Fruit and Vegetable Preservation Technology, Zhejiang International Scientific and Technological Cooperation Base of Health Food Manufacturing and Quality Control, Fuli Institute of Food Science, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Xingqian Ye
- National-Local Joint Engineering Laboratory of Intelligent Food Technology and Equipment, Zhejiang Key Laboratory for Agro-Food Processing, Integrated Research Base of Southern Fruit and Vegetable Preservation Technology, Zhejiang International Scientific and Technological Cooperation Base of Health Food Manufacturing and Quality Control, Fuli Institute of Food Science, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| |
Collapse
|
7
|
Application of a Deep Eutectic Solvent for Dispersive Liquid–Liquid Microextraction of Trace Amount of Pb (II) in Water Samples and Determination by Microvolume UV–Vis Spectrophotometry. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2023. [DOI: 10.1007/s13369-022-07544-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
8
|
Andruch V, Kalyniukova A, Płotka-Wasylka J, Jatkowska N, Snigur D, Zaruba S, Płatkiewicz J, Zgoła-Grześkowiak A, Werner J. Application of deep eutectic solvents in sample preparation for analysis (update 2017–2022). Part A: Liquid phase microextraction. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
9
|
Elik A, Altunay N. Optimization of vortex-assisted switchable hydrophilicity solvent liquid phase microextraction for the selective extraction of vanillin in different matrices prior to spectrophotometric analysis. Food Chem 2023; 399:133929. [DOI: 10.1016/j.foodchem.2022.133929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 07/23/2022] [Accepted: 08/09/2022] [Indexed: 10/15/2022]
|
10
|
|
11
|
Zhong Y, Ji M, Hu Y, Li G, Xiao X. Progress of Environmental Sample Preparation for Elemental Analysis. J Chromatogr A 2022; 1681:463458. [DOI: 10.1016/j.chroma.2022.463458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 08/22/2022] [Accepted: 08/29/2022] [Indexed: 10/14/2022]
|
12
|
Shishov A, Savinov S, Volodina N, Gurev I, Bulatov A. Deep eutectic solvent-based extraction of metals from oil samples for elemental analysis by ICP-OES. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107456] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
13
|
Mahmoudian M, Sarrafi AHM, Konoz E, Niazi A. Application of DLLME‐SFO as a Green Analytical Tool for Determination of Trace Amounts of Cadmium and Lead in Vegetables and Fruits using FAAS: Optimization Using Box‐Behnken Design**. ChemistrySelect 2022. [DOI: 10.1002/slct.202102488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Masoumeh Mahmoudian
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Amir Hossein Mohsen Sarrafi
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Elaheh Konoz
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Ali Niazi
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| |
Collapse
|
14
|
Patle A, Kurrey R, Deb MK, Patle TK, Sinha D, Shrivas K. Analytical approaches on some selected toxic heavy metals in the environment and their socio-environmental impacts: A meticulous review. J INDIAN CHEM SOC 2022. [DOI: 10.1016/j.jics.2022.100545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
15
|
Shishov A, Volodina N, Semenova E, Navolotskaya D, Ermakov S, Bulatov A. Reversed-phase dispersive liquid-liquid microextraction based on decomposition of deep eutectic solvent for the determination of lead and cadmium in vegetable oil. Food Chem 2022; 373:131456. [PMID: 34731809 DOI: 10.1016/j.foodchem.2021.131456] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 09/21/2021] [Accepted: 10/19/2021] [Indexed: 11/04/2022]
Abstract
In this work, a reversed-phase dispersive liquid-liquid microextraction procedure based on the decomposition of deep eutectic solvent was suggested for the first time. The procedure was utilized for fast and simple separation of lead and cadmium from vegetable oil samples. The procedure assumed mixing of oil sample and DES based on menthol, formic acid and water. Water as component of DES promoted its decomposition in sample matrix resulting menthol dissolution in the sample phase and dispersion of aqueous formic acid solution. In this procedure menthol acted as a dispersive solvent during DES decomposition for dispersion of aqueous formic acid solution. The metals were determined by the square-wave anodic stripping voltammetry. The limits of detection, were 0.01 µg kg-1 for lead and 0.006 µg kg-1 for cadmium. The RSD was less then 6% for both analytes. The enrichment factor was 36 and 39 for lead and cadmium, respectively.
Collapse
Affiliation(s)
- Andrey Shishov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia.
| | - Natalia Volodina
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Ekaterina Semenova
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Daria Navolotskaya
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Sergey Ermakov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Andrey Bulatov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| |
Collapse
|
16
|
Ezoddin M, Abdi K, Behnamipour S, Javadi MHS. Air assisted in situ deep eutectic solvent decomposition followed by the solidification of floating organic droplets-liquid-liquid microextraction method for extraction of azole antifungal drugs in biological samples prior to high-performance liquid chromatography. J Sep Sci 2022; 45:1757-1765. [PMID: 35266301 DOI: 10.1002/jssc.202100965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 02/21/2022] [Accepted: 02/26/2022] [Indexed: 11/06/2022]
Abstract
A free dispersive method, air-assisted in situ deep eutectic solvent decomposition followed by the solidification of floating organic droplets liquid-liquid microextraction was indicated in this study. This technique was utilized to simultaneously ascertain some azole antifungal drugs prior to high-performance liquid chromatography. In this research, a quasi-hydrophobic deep eutectic solvent was formed from tetrabutylammonium bromide and 1-dodecanol as an organic solvent at a 1:2 molar ratio. The synthesized deep decomposition in the sample solution caused in situ dispersion of extraction solvent and analytes. Air-assisted enhanced a dispersion condition in the sample solution. 1-dodecanol as a green option was replaced with typical extraction solvents providing the advantages of a suitable freezing point near room temperature and low density. The effect of important analytical parameters on the extraction recovery of analytes was assessed. Under these optimal conditions, the limits of detection and limits of quantitation determined were in the range of 0.5-2.8 μg L-1 and 1.5-9 μg L-1 , for water, urine and plasma samples, respectively. The Intra-day and inter-day relative standard deviations (RSD% n = 5) were calculated to be 2.9-4.6 % and 4.2-8.9 %, respectively. The results represented the effectiveness of the developed method for the extraction and determination of analytes in biological samples. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Maryam Ezoddin
- Department of Chemistry, Payame Noor University(PNU), P.O. BOX 19395-4697, Tehran, Iran
| | - Khosrou Abdi
- Department of Radiopharmacy, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran.,Iranian National Center for Addiction Studies (INCAS), Tehran University of Medical Sciences, Tehran, Iran
| | - Somaye Behnamipour
- Research center of Environmental pollutants, Qom University of Medical Sciences, Qom, Iran
| | - Mahdiyeh H S Javadi
- Iranian National Center for Addiction Studies (INCAS), Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
17
|
Application of deep eutectic solvents in the pre-processing of atomic spectrometry analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116555] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
18
|
Andruch V, Halko R, Tuček J, Płotka-Wasylka J. Application of deep eutectic solvents in atomic absorption spectrometry. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116510] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
19
|
|
20
|
Islam A, Roy S, Teo SH, Khandaker S, Taufiq-Yap YH, Aziz AA, Monir MU, Rashid U, Vo DVN, Ibrahim ML, Znad H, Awual MR. Functional novel ligand based palladium(II) separation and recovery from e-waste using solvent-ligand approach. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2021.127767] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
21
|
Dispersive liquid-liquid microextraction based on deep eutectic solvent for elemental impurities determination in oral and parenteral drugs by inductively coupled plasma optical emission spectrometry. Anal Chim Acta 2021; 1185:339052. [PMID: 34711330 DOI: 10.1016/j.aca.2021.339052] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/03/2021] [Accepted: 09/07/2021] [Indexed: 01/09/2023]
Abstract
A simple, fast, sensitive and green pretreatment method for determination of Cd, Co, Hg, Ni, Pb and V in oral and parenteral drug samples using inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. According to United States Pharmacopoeia (USP), those metals must be reported in all pharmaceutical products for quality control evaluation (i.e., elemental impurities from classes 1 and 2A of USP Chapter 232). To improve the analytical capabilities of ICP OES, a dispersive liquid-liquid microextraction (DLLME) has performed using a safe, cheap and biodegradable deep eutectic solvent (DES) as extractant solvent (a mixture of 2:1 M ratio of DL-menthol and decanoic acid). Seven parameters affecting the microextraction efficiency have carefully optimized by multivariate analysis. Under optimized conditions, the DES-based DLLME-ICP OES procedure improved limit of quantitation (LOQ) values on range from 12 to 85-fold and afforded an enrichment factor on average 60-times higher than those obtained to direct ICP OES analysis. Consequently, LOQ values for Cd, Co, Hg, Ni, Pb and V have been on average 10-times lower than target limits recommended for drugs from parenteral route of administration. Trueness has evaluated by addition and recovery experiments following USP recommendations for three oral drug samples in liquid dosage form and three parenteral drugs. Recovery and RSD values have been within the range of 90-109% and 1-6%, respectively. All analytes were below the respectives LOQ values, hence, lower than the limits proposed by USP Chapter 232.
Collapse
|
22
|
Ortega-Zamora C, González-Sálamo J, Hernández-Borges J. Deep Eutectic Solvents Application in Food Analysis. Molecules 2021; 26:6846. [PMID: 34833939 PMCID: PMC8617738 DOI: 10.3390/molecules26226846] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 11/17/2022] Open
Abstract
Current trends in Analytical Chemistry are focused on the development of more sustainable and environmentally friendly procedures. However, and despite technological advances at the instrumental level having played a very important role in the greenness of the new methods, there is still work to be done regarding the sample preparation stage. In this sense, the implementation of new materials and solvents has been a great step towards the development of "greener" analytical methodologies. In particular, the application of deep eutectic solvents (DESs) has aroused great interest in recent years in this regard, as a consequence of their excellent physicochemical properties, general low toxicity, and high biodegradability if they are compared with classical organic solvents. Furthermore, the inclusion of DESs based on natural products (natural DESs, NADESs) has led to a notable increase in the popularity of this new generation of solvents in extraction techniques. This review article focuses on providing an overview of the applications and limitations of DESs in solvent-based extraction techniques for food analysis, paying especial attention to their hydrophobic or hydrophilic nature, which is one of the main factors affecting the extraction procedure, becoming even more important when such complex matrices are studied.
Collapse
Affiliation(s)
- Cecilia Ortega-Zamora
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, s/n., 38206 San Cristóbal de La Laguna, Spain;
| | - Javier González-Sálamo
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, s/n., 38206 San Cristóbal de La Laguna, Spain;
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, s/n., 38206 San Cristóbal de La Laguna, Spain
- Department of Chemistry, Sapienza University of Rome, P. le Aldo Moro 5, 00185 Rome, Italy
| | - Javier Hernández-Borges
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, s/n., 38206 San Cristóbal de La Laguna, Spain;
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, s/n., 38206 San Cristóbal de La Laguna, Spain
| |
Collapse
|
23
|
Tergitol@SiO2@Fe3O4 magnetic nano-material and experimental design methodology: An effective and selective adsorbent for solid phase microextraction and flame atomic absorption spectrometric analysis of lead in different matrixes. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106765] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
24
|
Özkalkan H, Saygili Canlidinç R. Investigation of the Conditions for Preconcentration of Cadmium Ions by Solid Phase Extraction Method Using Modified Juglans regia L. Shells. J AOAC Int 2021; 104:1246-1254. [PMID: 33757120 DOI: 10.1093/jaoacint/qsab042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 12/17/2020] [Accepted: 03/15/2021] [Indexed: 12/07/2022]
Abstract
BACKGROUND Juglans regia L. shells as agricultural waste can be considered as alternative sorbents to minimize the problems associated with heavy metal pollution. OBJECTIVE In this study, J. regia shells (JRS) and JRS modified with hydrazine hydrate (JRS-HH) were used as sorbents and compared for the preconcentration of Cd(II) ions from aqueous solution. METHODS For the characterization of sorbents, scanning electron microscopy and energy dispersive X-ray (SEM/EDX) analysis and Fourier transform infrared (FTIR) spectroscopy were used. For preconcentration, the solid phase extraction (SPE) technique was used. Preconcentration studies were performed by column method and pH, eluent type and concentration, sample volume, flow rate, and interfering ions effect were studied to determine the optimum column parameters. RESULTS The limit of detection (LOD) of the sorbents (JRS and JRS-HH) are 0.31 and 0.18 µg/L, respectively. According to the Langmuir isotherm model for both sorbents, for JRS KL = 0.030 L/mg, R2 = 0.992, 0.016 L/mg, and for JRS-HH KL = 0.016 L/mg, R2 = 0.998 and maximum adsorption capacities of the sorbents were found to be as 29.6 and 65.7 mg/g, respectively. The mean recoveries and RSD values at a 95% confidence level (N = 6) for Cd(II) were 100.9% and 3.42, and 100.6% and 3.79, for the JRS and JRS-HH sorbents, respectively. CONCLUSIONS Using this method good results were obtained when compared with those in the literature and the proposed method was successfully applied to the analysis of the certificated reference material (NIST 1640). HIGHLIGHTS JRS are an effective and inexpensive sorbent for the preconcentration of metal ions when modified. Thus, low-cost agricultural wastes are both recovered and have an economic value.
Collapse
Affiliation(s)
- Hüsna Özkalkan
- Kütahya Dumlupınar University, Science and Art Faculty, Department of Chemistry, 43100 Kütahya, Turkey
| | - Rukiye Saygili Canlidinç
- Kütahya Dumlupınar University, Science and Art Faculty, Department of Chemistry, 43100 Kütahya, Turkey
| |
Collapse
|
25
|
Characterization of the radiation shielding properties of fired lead sample for X-ray shielding applications. PROGRESS IN NUCLEAR ENERGY 2021. [DOI: 10.1016/j.pnucene.2021.103765] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Laosuwan M, Poonsawat C, Burakham R, Srijaranai S, Mukdasai S. A novel liquid colorimetric probe for highly selective and sensitive detection of lead (II). Food Chem 2021; 363:130254. [PMID: 34120039 DOI: 10.1016/j.foodchem.2021.130254] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 05/06/2021] [Accepted: 05/29/2021] [Indexed: 01/10/2023]
Abstract
A novel liquid colorimetric sensor based on deep eutectic solvent (DES) was developed for the preconcentration and detection of Pb2+ in fruit juice, milk and cereal samples. The colorimetric probe was simply fabricated by adding dithizone (DZ) into DES, prepared from choline chloride and phenol. Pb2+ was formed complex with DZ in the probe, providing hydrophobic complex of [Pb-DZ] which was simultaneously extracted into DES and the color was changed from light orange to carmine red. The enriched [Pb-DZ] in DES was detected using spectrophotometer at 520 nm and naked-eyes. In addition, a smartphone in combination with an Image J program was used as an alternative detection device. Under optimal conditions, the enrichment factor was 92 with LOD of 2.1 µg L-1 and the linear range was 0.007-0.075 mg L-1. The proposed liquid colorimetric sensor was successfully applied for Pb2+ detection in various food samples and the results were in good agreement with those obtained by FAAS. The advantages of this method are simple, rapid, environmental friendly and low cost.
Collapse
Affiliation(s)
- Melasinee Laosuwan
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Choosak Poonsawat
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Rodjana Burakham
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Supalax Srijaranai
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Siriboon Mukdasai
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand.
| |
Collapse
|
27
|
Torbati M, Gonbari Milani P, Farajzadeh MA, Afshar Mogaddam MR. Development of an Ion-Pair Dispersive Liquid-Liquid Microextraction Method Based on a Ternary Deep Eutectic Solvent for Determination of Some Herbicide Residues in Edible Oil Samples. J Chromatogr Sci 2021; 60:88-95. [PMID: 33712851 DOI: 10.1093/chromsci/bmab026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 01/15/2021] [Accepted: 02/06/2021] [Indexed: 11/14/2022]
Abstract
An ion-pair deep eutectic solvent (DES)-based dispersive liquid-liquid microextraction method was introduced and applied for the extraction of some acidic herbicides from edible oil samples prior to their determination by high performance liquid chromatography. First, a ternary DES composed of decanoic acid, dichloroacetic acid, and phosphocholine chloride is prepared under mild conditions. Then, the analytes are extracted into an alkaline solution from the oil samples by deprotonation of the herbicides. Afterward, the deprotonated analytes are extracted into the prepared DES with the aid of tri-butyl amine (as an ion-pair agent) in the presence of acetic acid (as a pH adjustment agent and dispersive solvent). The validation parameters indicated that the method has low limits of detection (0.09-0.72 ng mL-1) and quantification (0.30-2.3 ng mL-1), an acceptable percision (relative standard deviation ≤ 9.0%) and high extraction recoveries (85-94%), and enrichment factors (566-626). The method was used in the analysis of 35 edible oil samples to assessment the studied analytes and the presence of haloxyfop was confirmed in three corn oils.
Collapse
Affiliation(s)
- Mohammadali Torbati
- Department of Food Science and Technology, Faculty of Nutrition, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Payam Gonbari Milani
- Department of Food Science and Technology, Faculty of Nutrition, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.,Engineering Faculty, Near East University, 99138 Nicosia, North Cyprus, Mersin 10, Turkey
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,Drug Applied Science, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
28
|
Yahya M, Kesekler S, Durukan İ, Arpa Ç. Determination of prohibited lead and cadmium traces in hair dyes and henna samples using ultrasound assisted-deep eutectic solvent-based liquid phase microextraction followed by microsampling-flame atomic absorption spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1058-1068. [PMID: 33570530 DOI: 10.1039/d0ay02235g] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this study ultrasound assisted-deep eutectic solvent-based liquid phase microextraction followed by microsampling-flame atomic absorption spectrometry was developed to determine prohibited lead and cadmium traces in hair dye and henna samples. For this purpose, deep eutectic solvent, prepared from choline chloride and phenol, was used as an extraction solvent, dithizone was used as a complexing agent, and THF was used as an aprotic solvent. All parameters that affect extraction efficiency, such as pH, the DES volume and composition, the extraction time, the amount of dithizone, were optimized. Under the optimal conditions, for Pb(ii) and Cd(ii), enhancement factors of 92 and 57, LODs of 2.5 μg L-1 and 0.75 μg L-1, LOQs of 7.8 μg L-1 and 2.5 μg L-1, linear working ranges of 10-250 μg L-1 and 2.5-50 μg L-1, were obtained, respectively. Relative standard deviation (n = 10) was calculated to be 2.7 for 100 μg L-1 of Pb(ii) and 2.1 for 25 μg L-1 of Cd(ii). The matrix effect was investigated by comparing the solvent-based calibration curve with the matrix-matched calibration curve. The determination of lead and cadmium in hair dye and henna samples without being affected by the sample matrix was successfully performed. The lead content was between 1.3 and 6.5 μg g-1, and the cadmium content was between 0.028 and 0.54 μg g-1 for the selected hair dye and henna samples.
Collapse
Affiliation(s)
- Maha Yahya
- Chemistry Department, Hacettepe University, 06800, Beytepe, Ankara, Turkey.
| | - Sare Kesekler
- Chemistry Department, Hacettepe University, 06800, Beytepe, Ankara, Turkey.
| | - İlknur Durukan
- Environmental Engineering Department, Hacettepe University, 06800, Beytepe, Ankara, Turkey
| | - Çiğdem Arpa
- Chemistry Department, Hacettepe University, 06800, Beytepe, Ankara, Turkey.
| |
Collapse
|
29
|
A comprehensive review on application of the syringe in liquid- and solid-phase microextraction methods. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2021. [DOI: 10.1007/s13738-020-02025-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
30
|
Burratti L, Ciotta E, De Matteis F, Prosposito P. Metal Nanostructures for Environmental Pollutant Detection Based on Fluorescence. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:276. [PMID: 33494342 PMCID: PMC7911013 DOI: 10.3390/nano11020276] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 01/15/2021] [Accepted: 01/18/2021] [Indexed: 12/14/2022]
Abstract
Heavy metal ions and pesticides are extremely dangerous for human health and environment and an accurate detection is an essential step to monitor their levels in water. The standard and most used methods for detecting these pollutants are sophisticated and expensive analytical techniques. However, recent technological advancements have allowed the development of alternative techniques based on optical properties of noble metal nanomaterials, which provide many advantages such as ultrasensitive detection, fast turnover, simple protocols, in situ sampling, on-site capability and reduced cost. This paper provides a review of the most common photo-physical effects impact on the fluorescence of metal nanomaterials and how these processes can be exploited for the detection of pollutant species. The final aim is to provide readers with an updated guide on fluorescent metallic nano-systems used as optical sensors of heavy metal ions and pesticides in water.
Collapse
Affiliation(s)
- Luca Burratti
- Department of Industrial Engineering and INSTM, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy; (L.B.); (F.D.M.)
| | - Erica Ciotta
- Institute for Microelectronics and Microsystems (IMM) CNR Tor Vergata, Via del Fosso del Cavaliere 100, 00133 Rome, Italy;
| | - Fabio De Matteis
- Department of Industrial Engineering and INSTM, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy; (L.B.); (F.D.M.)
| | - Paolo Prosposito
- Department of Industrial Engineering and INSTM, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy; (L.B.); (F.D.M.)
| |
Collapse
|
31
|
Mohebbi A, Farajzadeh MA, Afshar Mogaddam MR, Nemati M. Development of a Stirring-Dependent Magnetic Dispersive Solid Phase Extraction Method Coupled with Ferrofluid-Based Dispersive Liquid–Liquid Microextraction for the Extraction of Some Pyrethroid Pesticides from Fruit Juices. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-020-01918-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
32
|
Insights into coacervative and dispersive liquid-phase microextraction strategies with hydrophilic media – A review. Anal Chim Acta 2021; 1143:225-249. [DOI: 10.1016/j.aca.2020.08.022] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 12/18/2022]
|
33
|
Fu H, Wang X, Sang H, Liu J, Lin X, Zhang L. Highly efficient absorption of carbon dioxide by EG-assisted DBU-based deep eutectic solvents. J CO2 UTIL 2021. [DOI: 10.1016/j.jcou.2020.101372] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
34
|
Omidi F, Dehghani F, Jamaleddin Shahtaheri S. N-doped mesoporous carbon as a new sorbent for ultrasonic-assisted dispersive micro-solid-phase extraction of 1-naphthol and 2-naphthol, the biomarkers of exposure to naphthalene, from urine samples. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1160:122353. [PMID: 32947191 DOI: 10.1016/j.jchromb.2020.122353] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 08/24/2020] [Accepted: 08/26/2020] [Indexed: 12/11/2022]
Abstract
This study aimed to optimize a new sample preparation method using N-doped mesoporous carbon sorbent for simultaneous measurement of 1-naphthol and 2-naphthol, the biomarkers of exposure to naphthalene. The samples were analyzed using high-performance liquid chromatography supplied with ultraviolet detector (HPLC-UV). N-doped mesoporous carbon sorbent was obtained via the hard template procedure. The synthesized nanosorbent was then characterized by transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET), and elemental analysis (CHN). The effective factors in the extraction of the studied biomarkers were examined by the Box-Behnken (BBD) methodology. Regarding the optimum conditions, the sketched calibration curve for naphthols was linear in the concentration levels of 1-600 µg L-1 for human urine samples. The accuracy and reproducibility of the introduced method were determined using the relative recovery (RR %) and relative standard deviation (RSD %) tests on the fortified urine samples. RR% and RSD% were found to be 97.0-101.2% and 3.1-9.0%, respectively. The calculated method detection limit of the optimized procedure was 0.3 µg L-1 and 0.5 µg L-1 for 1-naphthol and 2-naphthol, respectively.
Collapse
Affiliation(s)
- Fariborz Omidi
- Research Center for Environmental Determinants of Health (RCEDH), Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Fatemeh Dehghani
- Department of Occupational Health Engineering, School of Public Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Seyed Jamaleddin Shahtaheri
- Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran; Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
35
|
Jagirani MS, Soylak M. Review: Microextraction Technique Based New Trends in Food Analysis. Crit Rev Anal Chem 2020; 52:968-999. [PMID: 33253048 DOI: 10.1080/10408347.2020.1846491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Food chemistry is the study and classification of the quality and origin of foods. The identification of definite biomarkers and the determination of residue contaminants such as toxins, pesticides, metals, human and veterinary drugs, which are a very common source of food-borne diseases. The food analysis is continuously demanding the improvement of more robust, sensitive, highly efficient, and economically beneficial analytical approaches to promise the traceability, safety, and quality of foods in the acquiescence with the consumers and legislation demands. The traditional methods have been used at the starting of the 20th century based on wet chemical methods. Now it existing the powerful analytical techniques used in food analysis and safety. This development has led to substantial enhancements in the analytical accuracy, precision, sensitivity, selectivity, thereby mounting the applied range of food applications. In the present decade, microextraction (micro-scale extraction) pays more attention due to its futures such as low consumption of solvent and sample, throughput analysis easy to operate, greener, robotics, and miniaturization, different adsorbents have been used in the microextraction process with unique nature recognized with wide range applications.
Collapse
Affiliation(s)
- Muhammed Saqaf Jagirani
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,National Center of Excellence in Analytical Chemistry, University of Sindh, Sindh, Pakistan
| | - Mustafa Soylak
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey
| |
Collapse
|
36
|
Habila MA, AlMasoud N, Alomar TS, AlOthman ZA, Yilmaz E, Soylak M. Deep Eutectic Solvent-Based Microextraction of Lead(II) Traces from Water and Aqueous Extracts before FAAS Measurements. Molecules 2020; 25:molecules25204794. [PMID: 33086622 PMCID: PMC7587555 DOI: 10.3390/molecules25204794] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 10/12/2020] [Accepted: 10/12/2020] [Indexed: 01/01/2023] Open
Abstract
Microextraction procedures for the separation of Pb(II) from water and food samples extracts were developed. A deep eutectic solvent composed of α-benzoin oxime and iron(III) chloride dissolved in phenol was applied as a phase separator support. In addition, this deep eutectic mixture worked as an efficient extractor of Pb(II). The developed microextraction process showed a high ability to tolerate the common coexisting ions in the real samples. The optimum conditions for quantitative recoveries of Pb(II) from aqueous extracts were at pH 2.0, conducted by adding 150 µL from the deep eutectic solvent. The quantitative recoveries were obtained with various initial sample volumes up to 30 mL. Limits of detection and limits of quantification of 0.008 and 0.025 µg L-1 were achieved with a relative standard deviation (RSD%) of 2.9, which indicates the accuracy and sensitivity of the developed procedure. Recoveries from the reference materials, including TMDA 64.2, TMDA 53.3, and NCSDC-73349, were 100%, 97%, and 102%, respectively. Real samples, such as tap, lake, and river water, as well as food samples, including salted peanuts, chickpeas, roasted yellow corn, pistachios, and almonds, were successfully applied for Pb(II) analysis by atomic absorption spectroscopy (AAS) after applying the developed deep eutectic solvent-based microextraction procedures.
Collapse
Affiliation(s)
- Mohamed A Habila
- Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
- Department of Chemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Najla AlMasoud
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia
| | - Taghrid S Alomar
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia
| | - Zeid A AlOthman
- Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
- Department of Chemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Erkan Yilmaz
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, 38039 Kayseri, Turkey
- Nanotechnology Research and Application Center (ERNAM), Erciyes University, 38039 Kayseri, Turkey
| | - Mustafa Soylak
- Department of Chemistry, Faculty of Sciences, Erciyes University, 38039 Kayseri, Turkey
| |
Collapse
|
37
|
Nyaba L, Nomngongo PN. Determination of trace metals in vegetables and water samples using dispersive ultrasound-assisted cloud point-dispersive µ-solid phase extraction coupled with inductively coupled plasma optical emission spectrometry. Food Chem 2020; 322:126749. [DOI: 10.1016/j.foodchem.2020.126749] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/02/2020] [Accepted: 04/03/2020] [Indexed: 10/24/2022]
|
38
|
Shishov A, Pochivalov A, Nugbienyo L, Andruch V, Bulatov A. Deep eutectic solvents are not only effective extractants. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115956] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
39
|
Zannou O, Koca I. Optimization and stabilization of the antioxidant properties from Alkanet (Alkanna tinctoria) with natural deep eutectic solvents. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2020.06.002] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
40
|
Khorshidi N, Rahimi M, Salimikia I. Application of aeration-assisted homogeneous liquid-liquid microextraction procedure using Box-Behnken design for determination of curcumin by HPLC. J Sep Sci 2020; 43:2513-2520. [PMID: 32255267 DOI: 10.1002/jssc.202000001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 03/13/2020] [Accepted: 03/26/2020] [Indexed: 01/30/2023]
Abstract
A simple, efficient, and rapid sample preparation method based on aeration-assisted homogeneous liquid-liquid microextraction was developed for determination of curcumin in food samples by high-performance liquid chromatography. The centrifuge step has been eliminated in this procedure. The effects of some variables, such as pH, volume of extraction solvent, extraction time, and salt effect, were studied through a Box-Behnken design method. Under the optimum conditions, calibration curves of curcumin were linear in the range of 0.08-4000 μg/mL with R2 = 0.997. Limit of detection and relative standard deviation were 0.019 μg/mL and 3.01%, respectively. The preconcentration factor achieved was 166. The proposed method was successfully applied to determination of curcumin in various food samples.
Collapse
Affiliation(s)
- Neda Khorshidi
- Razi Herbal Medicines Research Center, Lorestan University of Medical Sciences, Khorramabad, Iran
- Faculty of Pharmacy, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Marzieh Rahimi
- Razi Herbal Medicines Research Center, Lorestan University of Medical Sciences, Khorramabad, Iran
- Faculty of Pharmacy, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Iraj Salimikia
- Razi Herbal Medicines Research Center, Lorestan University of Medical Sciences, Khorramabad, Iran
- Department of Pharmacognosy, Faculty of Pharmacy, Lorestan University of Medical Sciences, Khorramabad, Iran
| |
Collapse
|
41
|
Tekin Z, Unutkan T, Erulaş F, Bakırdere EG, Bakırdere S. A green, accurate and sensitive analytical method based on vortex assisted deep eutectic solvent-liquid phase microextraction for the determination of cobalt by slotted quartz tube flame atomic absorption spectrometry. Food Chem 2020; 310:125825. [DOI: 10.1016/j.foodchem.2019.125825] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 10/18/2019] [Accepted: 10/28/2019] [Indexed: 12/20/2022]
|
42
|
Farajzadeh MA, Abbaspour M, Kazemian R, Afshar Mogaddam MR. Preparation of a new three-component deep eutectic solvent and its use as an extraction solvent in dispersive liquid-liquid microextraction of pesticides in green tea and herbal distillates. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2020; 100:1904-1912. [PMID: 31825526 DOI: 10.1002/jsfa.10200] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2019] [Revised: 11/11/2019] [Accepted: 12/11/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND A new solvent, deep eutectic solvent, in which there is growing interest, has been prepared and used as an extraction solvent in the dispersive liquid-liquid method of microextraction. To prepare the solvent, dichloroacetic acid, l-menthol, and n-butanol are mixed at a molar ratio of 4:1:1 and the deep eutectic solvent is formed after heating. Then a dispersive liquid-liquid microextraction method using the prepared solvent is used for the extraction and preconcentration of some pesticides from an aqueous sample. To carry out the procedure, the deep eutectic solvent is mixed with methanol and rapidly injected by a syringe into the aqueous sample containing the analytes. After centrifuging, an aliquot of the sedimented phase is injected into the gas chromatograph. The influence of several variables on the extraction efficiency was investigated and optimized. RESULTS Extraction recoveries and enrichment factors were obtained in the ranges of 53-86% and 1760-2853, respectively. The intra- (n = 6) and inter-day (n = 5) precision of the method was satisfactory, with relative standard deviations ≤ 7% obtained at two concentrations of 10 and 50 μg L-1 of each analyte. Moreover, detection and quantification limits for the target analytes were obtained in the ranges of 0.11-0.23 and 0.38-0.74 μg L-1 , respectively. CONCLUSION Different samples, including green tea, rose water, lemon balm, mint, and pussy willow distillates were analyzed successfully using the method that was developed, and chlorpyrifos was found in rose water at a concentration of 17 ± 1 μg L-1 (n = 3). © 2019 Society of Chemical Industry.
Collapse
Affiliation(s)
- Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
- Engineering Faculty, Near East University, Nicosia, North Cyprus, Mersin, Turkey
| | - Maryam Abbaspour
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Roya Kazemian
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | | |
Collapse
|
43
|
|
44
|
Sivrikaya S. A deep eutectic solvent based liquid phase microextraction for the determination of caffeine in Turkish coffee samples by HPLC-UV. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2020; 37:488-495. [DOI: 10.1080/19440049.2020.1711972] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Sezen Sivrikaya
- Faculty of Technology, Polymer Engineering Department, Duzce University, Duzce, Turkey
| |
Collapse
|
45
|
Air–assisted liquid–liquid microextraction; principles and applications with analytical instruments. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115734] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
46
|
Zaman BT, Erulaş AF, Chormey DS, Bakirdere S. Combination of stearic acid coated magnetic nanoparticle based sonication assisted dispersive solid phase extraction and slotted quartz tube-flame atomic absorption spectrophotometry for the accurate and sensitive determination of lead in red pepper samples and assessment of green profile. Food Chem 2020; 303:125396. [DOI: 10.1016/j.foodchem.2019.125396] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 07/15/2019] [Accepted: 08/18/2019] [Indexed: 11/25/2022]
|
47
|
|
48
|
Li G, Row KH. Utilization of deep eutectic solvents in dispersive liquid-liquid micro-extraction. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115651] [Citation(s) in RCA: 89] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
49
|
Niu X, Liu Y, Wang F, Luo D. Highly sensitive and selective optical sensor for lead ion detection based on liquid crystal decorated with DNAzyme. OPTICS EXPRESS 2019; 27:30421-30428. [PMID: 31684289 DOI: 10.1364/oe.27.030421] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 09/29/2019] [Indexed: 05/22/2023]
Abstract
Lead ions (Pb2+) are one of the major environmental pollutants that are dangerous for human health, thus the detection methods of Pb2+ become very important as well. However, most reported techniques suffer from drawbacks such as long time, expensive equipment and complicated testing process, which prevent the use of real-time application. Herein, we demonstrate a novel liquid crystal optical sensor for detection of Pb2+ based on DNAzyme and its combined strand. The ordered and disordered configuration of liquid crystals, induced by complementary DNA strand and catalytically cleaved DNA in presence of lead ion separately, leads to dark and bright optical image under POM. The proposed naked-eye optical sensor possesses an extremely broad detection range of Pb2+ from 50 nM to 500 µM, with a low detection limit about 36.8 nM. The sensor also demonstrates high selectivity of Pb2+ from many other metal ions. The proposal LC sensor is highly sensitive and selective for Pb2+ detection, which provides a novel platform for other heavy metal, DNAs or antigen in biological and chemical fields by modifying sensing molecules.
Collapse
|
50
|
Farajzadeh MA, Abbaspour M, Kazemian R. Synthesis of a green high density deep eutectic solvent and its application in microextraction of seven widely used pesticides from honey. J Chromatogr A 2019; 1603:51-60. [DOI: 10.1016/j.chroma.2019.06.051] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 06/24/2019] [Accepted: 06/24/2019] [Indexed: 10/26/2022]
|