1
|
Hanif S, Muhammad P, Niu Z, Ismail M, Morsch M, Zhang X, Li M, Shi B. Nanotechnology‐Based Strategies for Early Diagnosis of Central Nervous System Disorders. ADVANCED NANOBIOMED RESEARCH 2021. [DOI: 10.1002/anbr.202100008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Affiliation(s)
- Sumaira Hanif
- Henan-Macquarie University Joint Centre for Biomedical Innovation School of Life Sciences Henan University Kaifeng Henan 475004 China
| | - Pir Muhammad
- Henan-Macquarie University Joint Centre for Biomedical Innovation School of Life Sciences Henan University Kaifeng Henan 475004 China
| | - Zheng Niu
- Province's Key Lab of Brain Targeted Bionanomedicine School of Pharmacy Henan University Kaifeng Henan 475004 China
| | - Muhammad Ismail
- Henan-Macquarie University Joint Centre for Biomedical Innovation School of Life Sciences Henan University Kaifeng Henan 475004 China
| | - Marco Morsch
- Department of Biomedical Sciences Macquarie University Centre for Motor Neuron Disease Research Macquarie University NSW 2109 Australia
| | - Xiaoju Zhang
- Department of Respiratory and Critical Care Medicine Henan Provincial People's Hospital Zhengzhou Henan 450003 China
| | - Mingqiang Li
- Laboratory of Biomaterials and Translational Medicine The Third Affiliated Hospital Sun Yat-sen University Guangzhou Guangdong 510630 China
| | - Bingyang Shi
- Department of Biomedical Sciences Faculty of Medicine & Health & Human Sciences Macquarie University NSW 2109 Australia
| |
Collapse
|
2
|
Weiger M, Pruessmann KP. Short-T 2 MRI: Principles and recent advances. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 114-115:237-270. [PMID: 31779882 DOI: 10.1016/j.pnmrs.2019.07.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 07/14/2019] [Accepted: 07/26/2019] [Indexed: 06/10/2023]
Abstract
Among current modalities of biomedical and diagnostic imaging, MRI stands out by virtue of its versatile contrast obtained without ionizing radiation. However, in various cases, e.g., water protons in tissues such as bone, tendon, and lung, MRI performance is limited by the rapid decay of resonance signals associated with short transverse relaxation times T2 or T2*. Efforts to address this shortcoming have led to a variety of specialized short-T2 techniques. Recent progress in this field expands the choice of methods and prompts fresh considerations with regard to instrumentation, data acquisition, and signal processing. In this review, the current status of short-T2 MRI is surveyed. In an attempt to structure the growing range of techniques, the presentation highlights overarching concepts and basic methodological options. The most frequently used approaches are described in detail, including acquisition strategies, image reconstruction, hardware requirements, means of introducing contrast, sources of artifacts, limitations, and applications.
Collapse
Affiliation(s)
- Markus Weiger
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.
| | - Klaas P Pruessmann
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
3
|
Lu X, Jang H, Ma Y, Jerban S, Chang EY, Du J. Ultrashort Echo Time Quantitative Susceptibility Mapping (UTE-QSM) of Highly Concentrated Magnetic Nanoparticles: A Comparison Study about Different Sampling Strategies. Molecules 2019; 24:E1143. [PMID: 30909448 PMCID: PMC6471558 DOI: 10.3390/molecules24061143] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 03/16/2019] [Accepted: 03/19/2019] [Indexed: 12/11/2022] Open
Abstract
The ability to accurately and non-invasively quantify highly concentrated magnetic nanoparticles (MNPs) is desirable for many emerging applications. Ultrashort echo time quantitative susceptibility mapping (UTE-QSM) has demonstrated the capability to detect high iron concentrations. In this study, we aimed to investigate the effect of different sampling trajectories on the accuracy of quantification based on MNPs acquired through UTE-QSM. A phantom with six different MNP concentrations was prepared for UTE-QSM study with different UTE sampling trajectories, including radial acquisition, continuous single point imaging (CSPI), and Cones with four different gradient stretching factors of 1.0, 1.2, 1.4, and 1.6. No significant differences were found in QSM values derived from the different UTE sampling strategies, suggesting that the UTE-QSM technique could be accelerated with extended Cones sampling.
Collapse
Affiliation(s)
- Xing Lu
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
- Institute of Electrical Engineering, Chinese Academy of Science, Beijing 100190, China.
| | - Hyungseok Jang
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
| | - Yajun Ma
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
| | - Saeed Jerban
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
| | - Eric Y Chang
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, CA 92037, USA.
| | - Jiang Du
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA.
| |
Collapse
|
4
|
Tang W, Fan W, Lau J, Deng L, Shen Z, Chen X. Emerging blood–brain-barrier-crossing nanotechnology for brain cancer theranostics. Chem Soc Rev 2019; 48:2967-3014. [DOI: 10.1039/c8cs00805a] [Citation(s) in RCA: 242] [Impact Index Per Article: 48.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The advancements, perspectives, and challenges in blood–brain-barrier (BBB)-crossing nanotechnology for effective brain tumor delivery and highly efficient brain cancer theranostics.
Collapse
Affiliation(s)
- Wei Tang
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| | - Wenpei Fan
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| | - Joseph Lau
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| | - Liming Deng
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| | - Zheyu Shen
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| | - Xiaoyuan Chen
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Institutes of Health (NIH)
- Bethesda
- USA
| |
Collapse
|
5
|
Lu X, Ma Y, Chang EY, He Q, Searleman A, von Drygalski A, Du J. Simultaneous quantitative susceptibility mapping (QSM) and R2* for high iron concentration quantification with 3D ultrashort echo time sequences: An echo dependence study. Magn Reson Med 2018; 79:2315-2322. [PMID: 29314215 DOI: 10.1002/mrm.27062] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 12/05/2017] [Accepted: 12/05/2017] [Indexed: 12/12/2022]
Abstract
PURPOSE To evaluate the echo dependence of 3D ultrashort echo time (TE) quantitative susceptibility mapping (3D UTE-QSM) and effective transverse relaxation rate ( R2*) measurement in the setting of high concentrations of iron oxide nanoparticles. METHODS A phantom study with iron concentrations ranging from 2 to 22 mM was performed using a 3D UTE Cones sequence. Simultaneous QSM processing with morphology-enabled dipole inversion (MEDI) and R2* single exponential fitting was conducted offline with the acquired 3D UTE data. The dependence of UTE-QSM and R2* on echo spacing (ΔTE) and first TE (TE1 ) was investigated. RESULTS A linear relationship was observed between UTE-QSM measurement and iron concentration up to 22 mM only, with the minimal TE1 of 0.032 ms and ΔTE of less than 0.1 ms. A linear relationship was observed between R2* and iron concentration up to 22 mM only when TE1 was less than 0.132 ms and ΔTE was less than 1.2 ms. UTE-QSM with MEDI processing showed strong dependence on ΔTE and TE1 , especially at high iron concentrations. CONCLUSION UTE-QSM is more sensitive than R2* measurement to TE selection. Both an ultrashort TE1 and a small ΔTE are needed to achieve accurate QSM for high iron concentrations. Magn Reson Med 79:2315-2322, 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Xing Lu
- Department of Radiology, University of California, San Diego, California, USA.,Institute of Electrical Engineering, Chinese Academy of Science, Beijing, China
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, California, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, California, USA.,Radiology Service, VA San Diego Healthcare System, San Diego, California, USA
| | - Qun He
- Department of Radiology, University of California, San Diego, California, USA
| | - Adam Searleman
- Department of Radiology, University of California, San Diego, California, USA
| | - Annette von Drygalski
- Department of Medicine, Division of Hematology/Oncology, University of California, San Diego, California, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, California, USA
| |
Collapse
|
6
|
Korte JC, Layton KJ, Tahayori B, Farrell PM, Moore SM, Johnston LA. NMR spectroscopy using Rabi modulated continuous wave excitation. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
7
|
Magnitsky S, Zhang J, Idiyatullin D, Mohan G, Garwood M, Lane NE, Majumdar S. Positive contrast from cells labeled with iron oxide nanoparticles: Quantitation of imaging data. Magn Reson Med 2017; 78:1900-1910. [PMID: 28097749 DOI: 10.1002/mrm.26585] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 11/18/2016] [Accepted: 11/23/2016] [Indexed: 01/05/2023]
Abstract
PURPOSE Conventional T2 -weighted MRI produces a hypointense signal from iron-labeled cells, which renders quantification unfeasible. We tested a SWeep Imaging with Fourier Transformation (SWIFT) MRI pulse sequence to generate a quantifiable hyperintense signal from iron-labeled cells. METHODS Mesenchymal stem cells (MSCs) were labeled with different concentrations of iron oxide particles and examined for cell viability, proliferation, and differentiation. The SWIFT sequence was optimized to detect and quantify the amount of iron in the muscle tissue after injection of iron oxide solution and iron-labeled MSCs. RESULTS The incubation of MSCs with iron oxide and low concentration of poly-L-lysine mixture resulted in an internalization of up to 22 pg of iron per cell with no adverse effect on MSCs. Phantom experiments showed a dependence of SWIFT signal intensity on the excitation flip angle. The hyperintense signal from iron-labeled cells or solutions was detected, and an amount of the iron oxide in the tissue was quantified with the variable flip angle method. CONCLUSIONS The SWIFT sequence can produce a quantifiable hyperintense MRI signal from iron-labeled cells. The graft of 18 x 106 cells was detectable for 19 days after injection and the amount of iron was quantifiable. The proposed protocol simplifies the detection and provides a means to quantify cell numbers. Magn Reson Med 78:1900-1910, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sergey Magnitsky
- Musculoskeletal Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Jinjin Zhang
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Djaudat Idiyatullin
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Geetha Mohan
- Center for Musculoskeletal Health, University of California at Davis School of Medicine, Sacramento, California, USA
| | - Michael Garwood
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Nancy E Lane
- Center for Musculoskeletal Health, University of California at Davis School of Medicine, Sacramento, California, USA
| | - Sharmila Majumdar
- Musculoskeletal Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| |
Collapse
|
8
|
Zhu L, Zhou Z, Mao H, Yang L. Magnetic nanoparticles for precision oncology: theranostic magnetic iron oxide nanoparticles for image-guided and targeted cancer therapy. Nanomedicine (Lond) 2016; 12:73-87. [PMID: 27876448 DOI: 10.2217/nnm-2016-0316] [Citation(s) in RCA: 151] [Impact Index Per Article: 18.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Recent advances in the development of magnetic nanoparticles (MNPs) have shown promise in the development of new personalized therapeutic approaches for clinical management of cancer patients. The unique physicochemical properties of MNPs endow them with novel multifunctional capabilities for imaging, drug delivery and therapy, which are referred to as theranostics. To facilitate the translation of those theranostic MNPs into clinical applications, extensive efforts have been made on designing and improving biocompatibility, stability, safety, drug-loading ability, targeted delivery, imaging signal and thermal- or photodynamic response. In this review, we provide an overview of the physicochemical properties, toxicity and theranostic applications of MNPs with a focus on magnetic iron oxide nanoparticles.
Collapse
Affiliation(s)
- Lei Zhu
- Departments of Surgery & Radiology & Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Zhiyang Zhou
- Departments of Surgery & Radiology & Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA.,Xiangya School of Medicine, Central South University, Changsha, Hunan 410008, China
| | - Hui Mao
- Departments of Surgery & Radiology & Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Lily Yang
- Departments of Surgery & Radiology & Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA
| |
Collapse
|
9
|
Hong W, He Q, Fan S, Carl M, Shao H, Chen J, Chang EY, Du J. Imaging and quantification of iron-oxide nanoparticles (IONP) using MP-RAGE and UTE based sequences. Magn Reson Med 2016; 78:226-232. [PMID: 27495266 DOI: 10.1002/mrm.26371] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 06/16/2016] [Accepted: 07/15/2016] [Indexed: 12/11/2022]
Abstract
PURPOSE To investigate two-dimensional (2D) and three-dimensional (3D) ultrashort echo time (UTE) and 3D magnetization-prepared rapid gradient-echo (MP-RAGE) sequences for the imaging of iron-oxide nanoparticles (IONP). METHODS The phantoms were composed of tubes filled with different IONP concentrations ranging from 2 to 45 mM. The tubes were fixed in an agarose gel phantom (0.9% by weight). Morphological imaging was performed with 3D MP-RAGE, 2D UTE, 2D adiabatic inversion recovery-prepared UTE (2D IR-UTE), 3D UTE with Cones trajectory (3D Cones), and 3D IR-Cones sequences. Quantitative assessment of IONP concentration was performed using R2*(1/T2*) and R1 (1/T1 ) measurements using a 3 Tesla (T) scanner. RESULTS The 3D MP-RAGE sequence provides high-contrast images of IONP with concentration up to 7.5 mM. Higher IONP concentration up to 37.5 mM can be detected with the UTE sequences, with the highest IONP contrast provided by the 3D IR-Cones sequence. A linear relationship was observed between R2* and IONP concentration up to ∼45 mM, and between R1 and IONP concentration up to ∼30 mM. CONCLUSION The clinical 3D MP-RAGE sequence can be used to assess lower IONP concentration up to 7.5 mM. The UTE sequences can be used to assess higher IONP concentration up to 45 mM. Magn Reson Med 78:226-232, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Wen Hong
- Department of Radiology, University of California, San Diego, California, USA.,Department of Radiology, China-Japan Friendship Hospital, Beijing, China
| | - Qun He
- Department of Radiology, University of California, San Diego, California, USA.,Ningbo Jansen NMR Technology Co., Ltd, Cixi, Zhejiang Province, China
| | - Shujuan Fan
- Department of Radiology, University of California, San Diego, California, USA
| | - Michael Carl
- Applied Science Lab, GE Healthcare, San Diego, California, USA
| | - Hongda Shao
- Department of Radiology, University of California, San Diego, California, USA
| | - Jun Chen
- Department of Radiology, University of California, San Diego, California, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, California, USA.,Radiology Service, VA San Diego Healthcare System, San Diego, California, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, California, USA
| |
Collapse
|
10
|
Zhou J, Li J, Ding X, Liu J, Luo Z, Liu Y, Ran Q, Cai K. Multifunctional Fe2O3@PPy-PEG nanocomposite for combination cancer therapy with MR imaging. NANOTECHNOLOGY 2015; 26:425101. [PMID: 26422003 DOI: 10.1088/0957-4484/26/42/425101] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In recent years, magnetic hyperthermia nanoparticles have drawn great attention for cancer therapy because they have no limitation of tissue penetration during the therapy process. In this study, cubic nanoporous Fe2O3 nanoparticles derived from cubic Prussian blue nanoparticles were used as magnetic cores to generate heat by alternating the current magnetic field (AMF) for killing cancer cells. In addition, polypyrrole (PPy) was coated on the surfaces of the cubic Fe2O3 nanoparticles to load doxorubicin hydrochloride (DOX). The PEG component was then physically adsorbed onto the surfaces of the nanoparticles, resulting in a Fe2O3@PPy-DOX-PEG nanocomposite. The nanocomposite was triggered by acid stimulus and AMF to release DOX, resulting in a remarkable combination therapeutic effect via chemotherapy and magnetic hyperthermia. Furthermore, the nanocomposite could realize magnetic resonance imaging (MRI) due to the magnetic core structure. The study provides an alternative for the development of new nanocomposites for combination cancer therapy with MR imaging in vivo.
Collapse
Affiliation(s)
- Jun Zhou
- Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, People's Republic of China
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Huang C, Ouyang J, Reese TG, Wu Y, El Fakhri G, Ackerman JL. Continuous MR bone density measurement using water- and fat-suppressed projection imaging (WASPI) for PET attenuation correction in PET-MR. Phys Med Biol 2015; 60:N369-81. [PMID: 26405761 PMCID: PMC4607313 DOI: 10.1088/0031-9155/60/20/n369] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Due to the lack of signal from solid bone in normal MR sequences for the purpose of MR-based attenuation correction, investigators have proposed using the ultrashort echo time (UTE) pulse sequence, which yields signal from bone. However, the UTE-based segmentation approach might not fully capture the intra- and inter-subject bone density variation, which will inevitably lead to bias in reconstructed PET images. In this work, we investigated using the water- and fat-suppressed proton projection imaging (WASPI) sequence to obtain accurate and continuous attenuation for bones. This approach is capable of accounting for intra- and inter-subject bone attenuation variations. Using data acquired from a phantom, we have found that that attenuation correction based on the WASPI sequence is more accurate and precise when compared to either conventional MR attenuation correction or UTE-based segmentation approaches.
Collapse
Affiliation(s)
- C Huang
- Center for Advanced Medical Imaging Sciences, Department of Imaging, Massachusetts General Hospital, Boston, MA 02114, USA. Department of Radiology, Harvard Medical School, Boston, MA 02115, USA. Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, NY 11794, USA
| | | | | | | | | | | |
Collapse
|
12
|
Weiger M, Wu M, Wurnig MC, Kenkel D, Boss A, Andreisek G, Pruessmann KP. ZTE imaging with long-T2 suppression. NMR IN BIOMEDICINE 2015; 28:247-254. [PMID: 25521814 DOI: 10.1002/nbm.3246] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2014] [Revised: 10/03/2014] [Accepted: 11/17/2014] [Indexed: 06/04/2023]
Abstract
Three-dimensional radial zero echo time (ZTE) imaging enables efficient direct MRI of tissues with rapid transverse relaxation. Yet, the feature of capturing signals with a wide range of T2 and T2 * values is accompanied by a lack of contrast between the corresponding tissues. In particular, the targeted short-T2 tissues may not be easily identified, and various approaches have been proposed to generate T2 contrast by reducing the long-T2 signal of water and/or fat. The aim of this work was to provide efficient long-T2 suppression for selective direct MRI of short-T2 tissues using the ZTE technique. For magnetization preparation, suppression pulses for water and fat were designed to provide both good T2 selectivity and off-resonance performance. To obtain high efficiency at short TRs, the pulses were applied in a segmented sequence scheme with minimized timing overhead, thus leading to a quasi-steady state of magnetization. The sequence timing was adjusted for optimal tissue contrast in musculoskeletal applications by means of simulations and experiments, incorporating both T2 and T1 of the involved tissues. The developed technique was employed for imaging of a lamb joint sample at 4.7 T. ZTE images were obtained with effective suppression of signals from tissues with long-T2 water, such as muscle or articular spaces, and fat. Hence, primarily short-T2 tissues were visible, such as bone and tendon. The MR image intensity of bone showed strong similarity with bone density imaged with micro-computed tomography.
Collapse
Affiliation(s)
- Markus Weiger
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | | | | | | | | | | | | |
Collapse
|