1
|
Ahmadi M, Ehrmann K, Koch T, Liska R, Stampfl J. From Unregulated Networks to Designed Microstructures: Introducing Heterogeneity at Different Length Scales in Photopolymers for Additive Manufacturing. Chem Rev 2024; 124:3978-4020. [PMID: 38546847 PMCID: PMC11009961 DOI: 10.1021/acs.chemrev.3c00570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 01/10/2024] [Accepted: 01/23/2024] [Indexed: 04/11/2024]
Abstract
Photopolymers have been optimized as protective and decorative coating materials for decades. However, with the rise of additive manufacturing technologies, vat photopolymerization has unlocked the use of photopolymers for three-dimensional objects with new material requirements. Thus, the originally highly cross-linked, amorphous architecture of photopolymers cannot match the expectations for modern materials anymore, revealing the largely unanswered question of how diverse properties can be achieved in photopolymers. Herein, we review how microstructural features in soft matter materials should be designed and implemented to obtain high performance materials. We then translate these findings into chemical design suggestions for enhanced printable photopolymers. Based on this analysis, we have found microstructural heterogenization to be the most powerful tool to tune photopolymer performance. By combining the chemical toolbox for photopolymerization and the analytical toolbox for microstructural characterization, we examine current strategies for physical heterogenization (fillers, inkjet printing) and chemical heterogenization (semicrystalline polymers, block copolymers, interpenetrating networks, photopolymerization induced phase separation) of photopolymers and put them into a material scientific context to develop a roadmap for improving and diversifying photopolymers' performance.
Collapse
Affiliation(s)
- Mojtaba Ahmadi
- Institute
of Materials Science and Technology, Technische
Universität Wien, Getreidemarkt 9BE, 1060 Vienna, Austria
| | - Katharina Ehrmann
- Institute
of Applied Synthetic Chemistry, Technische
Universität Wien, Getreidemarkt 9/163, 1060 Vienna, Austria
| | - Thomas Koch
- Institute
of Materials Science and Technology, Technische
Universität Wien, Getreidemarkt 9BE, 1060 Vienna, Austria
| | - Robert Liska
- Institute
of Applied Synthetic Chemistry, Technische
Universität Wien, Getreidemarkt 9/163, 1060 Vienna, Austria
| | - Jürgen Stampfl
- Institute
of Materials Science and Technology, Technische
Universität Wien, Getreidemarkt 9BE, 1060 Vienna, Austria
| |
Collapse
|
2
|
Microscale compressive behavior of hydrated lamellar bone at high strain rates. Acta Biomater 2021; 131:403-414. [PMID: 34245895 DOI: 10.1016/j.actbio.2021.07.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 11/20/2022]
Abstract
The increased risk of fracture in the elderly associated with metabolic conditions like osteoporosis poses a significant strain on health care systems worldwide. Due to bone's hierarchical nature, it is necessary to study its mechanical properties and failure mechanisms at several length scales. We conducted micropillar compression experiments on ovine cortical bone to assess the anisotropic mechanical response at the lamellar scale over a wide range of strain rates (10-4 to 8·102 s-1). At the microscale, lamellar bone exhibits a strain rate sensitivity similar to what is reported at the macroscale suggesting that it is an intrinsic property of the extracellular matrix. Significant shear band thickening was observed at high strain rates by HRSEM and STEM imaging. This is likely caused by the material's inability to accommodate the imposed deformation by propagation of thin kink bands and shear cracks at high strain rates, leading to shear band thickening and nucleation. The post-yield behavior is strain rate and direction dependent: hardening was observed for transverse oriented micropillars and hardening modulus increases with strain rate by a factor of almost 2, while axially oriented micropillars showed strain softening and an increase of the softening peak width and work to ultimate stress as a function of strain rate. This suggests that for compression at the micrometer scale, energy absorption in bone increases with strain rate. This study highlights the importance of investigating bone strength and post-yield behavior at lower length scales, under hydrated conditions and at clinically relevant strain rates. STATEMENT OF SIGNIFICANCE: We performed micropillar compression experiments of ovine cortical bone at two different orientations and over seven orders of magnitude of strain rate. Experiments were performed under humid condition to mimic the natural conditions of bone in a human body using a newly developed micro-indenter setup. The strain rate sensitivity was found to be of a similar magnitude to what has been reported for higher length scales, suggesting that the strain rate sensitivity is an intrinsic property of the bone extracellular matrix. In addition, localized shear deformation in thick bands was observed for the first time at high strain rates, highlighting the importance of investigating bone under conditions representative of an accident or fall at several length scales.
Collapse
|
3
|
Balakumaran V, Alagirusamy R, Kalyanasundaram D. Epoxy based sandwich composite using three-dimensional integrally woven fabric as core strengthened with additional carbon face-sheets. J Mech Behav Biomed Mater 2021; 116:104317. [PMID: 33465695 DOI: 10.1016/j.jmbbm.2021.104317] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Revised: 12/31/2020] [Accepted: 01/03/2021] [Indexed: 11/29/2022]
Abstract
Sandwich composites are three-dimensional (3D) composite structures that offer higher stiffness with overall low density. However, they suffer from low strength; thus, not suited for load bearing applications. In this work, an attempt is made to develop a high strength lightweight sandwich composite suited for load-bearing applications. A sandwich composite based on 3D integrally woven fabric with thickness 3 mm as the core and strengthened with additional 2x2 twill woven carbon fabric face-sheets is reported. The samples were manufactured by wet hand lay co-lamination process using Araldite® LY 1564 epoxy as the matrix polymer and with fiber fraction of 50% by weight. The number of additional carbon face-sheets over the core was varied from two to eight in steps of two. The composite samples were experimented under three-point bending and edgewise compression tests to determine the flexural and compressive strengths in both warp and weft directions. The weft direction samples yielded higher flexural and compressive strengths due to the continuous arrangement of the core pile yarn. The samples with six carbon face-sheets tested along the weft direction offered the highest specific strengths of ~409 kN m/kg and 259 kN m/kg in bending and compression tests. Similarly, the flexural strength was ~340 MPa, and compressive strength was ~217 MPa. A detailed fractography study revealed no core crushing or compression failure of the core during bending tests.
Collapse
Affiliation(s)
- V Balakumaran
- Centre for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016, India.
| | - Ramasamy Alagirusamy
- Department of Textile and Fiber Engineering, Indian Institute of Technology, New Delhi, 110016, India.
| | - Dinesh Kalyanasundaram
- Centre for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016, India; Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi, 110029, India.
| |
Collapse
|
4
|
Huang W, Restrepo D, Jung JY, Su FY, Liu Z, Ritchie RO, McKittrick J, Zavattieri P, Kisailus D. Multiscale Toughening Mechanisms in Biological Materials and Bioinspired Designs. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1901561. [PMID: 31268207 DOI: 10.1002/adma.201901561] [Citation(s) in RCA: 172] [Impact Index Per Article: 34.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 04/08/2019] [Indexed: 05/04/2023]
Abstract
Biological materials found in Nature such as nacre and bone are well recognized as light-weight, strong, and tough structural materials. The remarkable toughness and damage tolerance of such biological materials are conferred through hierarchical assembly of their multiscale (i.e., atomic- to macroscale) architectures and components. Herein, the toughening mechanisms of different organisms at multilength scales are identified and summarized: macromolecular deformation, chemical bond breakage, and biomineral crystal imperfections at the atomic scale; biopolymer fibril reconfiguration/deformation and biomineral nanoparticle/nanoplatelet/nanorod translation, and crack reorientation at the nanoscale; crack deflection and twisting by characteristic features such as tubules and lamellae at the microscale; and structure and morphology optimization at the macroscale. In addition, the actual loading conditions of the natural organisms are different, leading to energy dissipation occurring at different time scales. These toughening mechanisms are further illustrated by comparing the experimental results with computational modeling. Modeling methods at different length and time scales are reviewed. Examples of biomimetic designs that realize the multiscale toughening mechanisms in engineering materials are introduced. Indeed, there is still plenty of room mimicking the strong and tough biological designs at the multilength and time scale in Nature.
Collapse
Affiliation(s)
- Wei Huang
- Department of Chemical and Environmental Engineering, University of California Riverside, Riverside, CA, 92521, USA
| | - David Restrepo
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, 78249, USA
| | - Jae-Young Jung
- Materials Science and Engineering Program, University of California San Diego, La Jolla, 92093, USA
| | - Frances Y Su
- Materials Science and Engineering Program, University of California San Diego, La Jolla, 92093, USA
| | - Zengqian Liu
- Department of Materials Science and Engineering, University of California Berkeley, Berkeley, CA, 94720, USA
- Materials Fatigue and Fracture Division, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China
| | - Robert O Ritchie
- Department of Materials Science and Engineering, University of California Berkeley, Berkeley, CA, 94720, USA
| | - Joanna McKittrick
- Materials Science and Engineering Program, University of California San Diego, La Jolla, 92093, USA
- Department of Mechanical and Aerospace Engineering, University of California San Diego, La Jolla, 92093, USA
| | - Pablo Zavattieri
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - David Kisailus
- Department of Chemical and Environmental Engineering, University of California Riverside, Riverside, CA, 92521, USA
- Materials Science and Engineering Program, University of California Riverside, Riverside, CA, 92521, USA
| |
Collapse
|
5
|
Organic and mechanical properties of Cervidae antlers: a review. Vet Res Commun 2016; 40:141-147. [PMID: 27618827 DOI: 10.1007/s11259-016-9663-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 09/05/2016] [Indexed: 10/21/2022]
Abstract
There is a resurgence of interest in the study of deer antlers. Recent research advocates their potential for use in bone xenografts. Using this working hypothesis, we can formulate many questions: do antlers really present unique or interesting mechanical properties, and if so, which factors affect these properties? Many other issues, including tissue compatibility, could be discussed; however, this article will focus on the biomechanical features of antlers. This paper reviews some answers found within current published material, and could help determine the optimal selection of some antlers for further experimental studies and clinical trials. Some general elements like anatomy and histology of deer antlers are briefly summarised. This paper will attempt to define the fundamental differences between skeletal bone and antler bone in terms of their organic and mechanical properties. We will then compare the previously published data, which details the mechanical properties of antlers from different species of Cervidae, by reviewing several aspects such as: sex; geographical situation; morphology; hydration state; and mineral composition. Some findings emerge: mechanical properties do not vary with gender or latitude, and the most important determining factor appears to be the species, alongside morphology and use of antlers. The state of hydration and mineral composition also has an influence on the mechanical properties of Cervidae antlers.
Collapse
|
6
|
Lefebvre A, Rochefort GY, Santos F, Le Denmat D, Salmon B, Pétillon JM. A Non-Destructive Method for Distinguishing Reindeer Antler (Rangifer tarandus) from Red Deer Antler (Cervus elaphus) Using X-Ray Micro-Tomography Coupled with SVM Classifiers. PLoS One 2016; 11:e0149658. [PMID: 26901355 PMCID: PMC4762490 DOI: 10.1371/journal.pone.0149658] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 02/03/2016] [Indexed: 11/19/2022] Open
Abstract
Over the last decade, biomedical 3D-imaging tools have gained widespread use in the analysis of prehistoric bone artefacts. While initial attempts to characterise the major categories used in osseous industry (i.e. bone, antler, and dentine/ivory) have been successful, the taxonomic determination of prehistoric artefacts remains to be investigated. The distinction between reindeer and red deer antler can be challenging, particularly in cases of anthropic and/or taphonomic modifications. In addition to the range of destructive physicochemical identification methods available (mass spectrometry, isotopic ratio, and DNA analysis), X-ray micro-tomography (micro-CT) provides convincing non-destructive 3D images and analyses. This paper presents the experimental protocol (sample scans, image processing, and statistical analysis) we have developed in order to identify modern and archaeological antler collections (from Isturitz, France). This original method is based on bone microstructure analysis combined with advanced statistical support vector machine (SVM) classifiers. A combination of six microarchitecture biomarkers (bone volume fraction, trabecular number, trabecular separation, trabecular thickness, trabecular bone pattern factor, and structure model index) were screened using micro-CT in order to characterise internal alveolar structure. Overall, reindeer alveoli presented a tighter mesh than red deer alveoli, and statistical analysis allowed us to distinguish archaeological antler by species with an accuracy of 96%, regardless of anatomical location on the antler. In conclusion, micro-CT combined with SVM classifiers proves to be a promising additional non-destructive method for antler identification, suitable for archaeological artefacts whose degree of human modification and cultural heritage or scientific value has previously made it impossible (tools, ornaments, etc.).
Collapse
Affiliation(s)
- Alexandre Lefebvre
- De la Préhistoire à l'Actuel, Culture, Environnement, Anthropologie—UMR 5199, University of Bordeaux, Bordeaux, France
- * E-mail:
| | - Gael Y. Rochefort
- EA 2496 Pathologies, Imagerie et Biothérapies oro-faciales, Plateforme Imagerie du Vivant, Dental School, Université Paris Descartes Sorbonne Paris Cité, Montrouge, France
| | - Frédéric Santos
- De la Préhistoire à l'Actuel, Culture, Environnement, Anthropologie—UMR 5199, University of Bordeaux, Bordeaux, France
| | - Dominique Le Denmat
- EA 2496 Pathologies, Imagerie et Biothérapies oro-faciales, Plateforme Imagerie du Vivant, Dental School, Université Paris Descartes Sorbonne Paris Cité, Montrouge, France
| | - Benjamin Salmon
- EA 2496 Pathologies, Imagerie et Biothérapies oro-faciales, Plateforme Imagerie du Vivant, Dental School, Université Paris Descartes Sorbonne Paris Cité, Montrouge, France
- Assistance Publique des Hôpitaux de Paris (AP-HP), Hôpitaux Universitaires PNVS, Service d’Odontologie Bretonneau, Paris, France
| | - Jean-Marc Pétillon
- Travaux et Recherches Archéologiques sur les Cultures, les Espaces et les Sociétés-UMR 5608, University Toulouse Jean Jaurès, Toulouse, France
| |
Collapse
|
7
|
Li F, Li J, Kou H, Huang T, Zhou L. Compressive mechanical compatibility of anisotropic porous Ti6Al4V alloys in the range of physiological strain rate for cortical bone implant applications. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:233. [PMID: 26384823 DOI: 10.1007/s10856-015-5565-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 09/08/2015] [Indexed: 06/05/2023]
Abstract
Porous titanium and its alloys are believed to be promising materials for bone implant applications, since they can reduce the "stress shielding" effect by tailoring porosity and improve fixation of implant through bone ingrowth. In the present work, porous Ti6Al4V alloys for biomedical application were fabricated by diffusion bonding of alloy meshes. Compressive mechanical behavior and compatibility in the range of physiological strain rate were studied under quasi-static and dynamic conditions. The results show that porous Ti6Al4V alloys possess anisotropic structure with elongated pores in the out-of-plane direction. For porous Ti6Al4V alloys with 60-70 % porosity, more than 40 % pores are in the range of 200-500 μm which is the optimum pore size suited for bone ingrowth. Quasi-static Young's modulus and yield stress of porous Ti6Al4V alloys with 30-70 % relative density are in the range of 6-40 GPa and 100-500 MPa, respectively. Quasi-static compressive properties can be quantitatively tailored by porosity to match those of cortical bone. Strain rate sensitivity of porous Ti6Al4V alloys is related to porosity. Porous Ti6Al4V alloys with porosity higher than 50 % show enhanced strain rate sensitivity, which is originated from that of base materials and micro-inertia effect. Porous Ti6Al4V alloys with 60-70 % porosity show superior compressive mechanical compatibility in the range of physiological strain rate for cortical bone implant applications.
Collapse
Affiliation(s)
- Fuping Li
- State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China
| | - Jinshan Li
- State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China
- National & Local Joint Engineering Research Center for Precision Thermalforming Technology of Advanced Metal Materials, Xi'an, 710072, People's Republic of China
| | - Hongchao Kou
- State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China.
- National & Local Joint Engineering Research Center for Precision Thermalforming Technology of Advanced Metal Materials, Xi'an, 710072, People's Republic of China.
| | - Tingting Huang
- State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China
| | - Lian Zhou
- State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi'an, 710072, People's Republic of China
| |
Collapse
|
8
|
Kierdorf U, Stoffels D, Kierdorf H. Element concentrations and element ratios in antler and pedicle bone of yearling red deer (Cervus elaphus) stags-a quantitative X-ray fluorescence study. Biol Trace Elem Res 2014; 162:124-33. [PMID: 25319008 DOI: 10.1007/s12011-014-0154-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2014] [Accepted: 10/07/2014] [Indexed: 10/24/2022]
Abstract
The present study compared the concentrations of different elements (Ca, P, Mg, Sr, Ba, K, S, Zn, Mn) as well as Ca/P, Ca/Mg, Sr/Ca, and Ba/Ca ratios in hard antler and pedicle bone of yearling red deer stags (n = 11). Pedicles showed higher concentrations of calcium and phosphorus and a higher Ca/Mg ratio than antlers, while antlers exhibited higher concentrations of potassium, sulfur, and manganese as well as higher Ca/P, Sr/Ca, and Ba/Ca ratios. The findings indicate that antlers are less mineralized and show less maturation of their bone mineral than pedicles. Antlers also showed a higher intrasample variation of mineralization than pedicles, which can be related to the shorter life span of the (deciduous) antlers compared to the (permanent) pedicles. It is suggested that antler bone formation is stopped before the theoretically possible degree of mineralization and mineral maturation is reached, resulting in antler biomechanical properties (high bending strength and work to fracture) that are well suited for their role in intraspecific fighting. It is further suggested that the differences in Sr/Ca and Ba/Ca ratios of antlers and pedicles are related to the dietary shift from milk to vegetation in combination with an increasing intestinal discrimination against Sr and Ba with age, resulting in a less marked difference in these ratios than would be expected based on the dietary shift alone. The findings of our study underscore the suitability of antlers and pedicles as models of bone mineralization and the influence of different animal-related and/or external factors on this process.
Collapse
Affiliation(s)
- Uwe Kierdorf
- Department of Biology, University of Hildesheim, Marienburger Platz 22, 31141, Hildesheim, Germany,
| | | | | |
Collapse
|
9
|
Histocompositional organization and toughening mechanisms in antler. J Struct Biol 2014; 187:129-148. [DOI: 10.1016/j.jsb.2014.06.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Revised: 06/04/2014] [Accepted: 06/13/2014] [Indexed: 12/16/2022]
|
10
|
Tüfekci K, Kayacan R, Kurbanoğlu C. Effects of gamma radiation sterilization and strain rate on compressive behavior of equine cortical bone. J Mech Behav Biomed Mater 2014; 34:231-42. [PMID: 24607761 DOI: 10.1016/j.jmbbm.2014.02.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2013] [Revised: 01/24/2014] [Accepted: 02/02/2014] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Gamma radiation has been widely used for sterilization of bone allograft. However, sterilization by gamma radiation damages the material properties of bone which is a major clinical concern since bone allograft is used in load bearing applications. While the degree of this damage is well investigated for quasi-static and cyclic loading conditions, there does not appear any information on mechanical behavior of gamma-irradiated cortical bone at high speed loading conditions. In this study, the effects of gamma irradiation on high strain rate compressive behavior of equine cortical bone were investigated using a Split Hopkinson Pressure Bar (SHPB). Quasi-static compression testing was also performed. METHODS Equine cortical bone tissue from 8year old retired racehorses was divided into two groups: non-irradiated and gamma-irradiated at 30kGy. Quasi-static and high strain rate compression tests were performed at average strain rates of 0.0045/s and 725/s, respectively. RESULTS Agreeing with previous results on the embrittlement of cortical bone when gamma-irradiated, the quasi-static results showed that gamma-irradiation significantly decreased ultimate strength (9%), ultimate strain (27%) and toughness (41%), while not having significant effect on modulus of elasticity, yield strain and resilience. More importantly, contrary to what is typically observed in quasi-static loading, the gamma-irradiated bone under high speed loading showed significantly higher modulus of elasticity (45%), ultimate strength (24%) and toughness (26%) than those of non-irradiated bone, although the failure was at a similar strain. SIGNIFICANCE Under high speed loading, the mechanical properties of bone allografts were not degraded by irradiation, in contrast to the degradation measured in this and prior studies under quasi-static loading. This result calls into question the assumption that bone allograft is always degraded by gamma irradiation, regardless of loading conditions. However, it needs further investigation to be translated positively in a clinical setting.
Collapse
Affiliation(s)
- Kenan Tüfekci
- Department of Mechanical Engineering, Süleyman Demirel University, 32260 Isparta, Turkey.
| | - Ramazan Kayacan
- Department of Mechanical Engineering, Süleyman Demirel University, 32260 Isparta, Turkey.
| | - Cahit Kurbanoğlu
- Department of Mechanical Engineering, İstanbul Medeniyet University, Göztepe Kadıköy - İstanbul, Turkey.
| |
Collapse
|
11
|
Hang F, Gupta HS, Barber AH. Nanointerfacial strength between non-collagenous protein and collagen fibrils in antler bone. J R Soc Interface 2013; 11:20130993. [PMID: 24352676 PMCID: PMC3899868 DOI: 10.1098/rsif.2013.0993] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Antler bone displays considerable toughness through the use of a complex nanofibrous structure of mineralized collagen fibrils (MCFs) bound together by non-collagenous proteins (NCPs). While the NCP regions represent a small volume fraction relative to the MCFs, significant surface area is evolved upon failure of the nanointerfaces formed at NCP-collagen fibril boundaries. The mechanical properties of nanointerfaces between the MCFs are investigated directly in this work using an in situ atomic force microscopy technique to pull out individual fibrils from the NCP. Results show that the NCP-fibril interfaces in antler bone are weak, which highlights the propensity for interface failure at the nanoscale in antler bone and extensive fibril pullout observed at antler fracture surfaces. The adhesion between fibrils and NCP is additionally suggested as being rate dependent, with increasing interfacial strength and fracture energy observed when pullout velocity decreases.
Collapse
Affiliation(s)
- Fei Hang
- Department of Materials, School of Engineering and Materials Science, Queen Mary University of London, , Mile End Road, London E1 4NS, UK
| | | | | |
Collapse
|