1
|
Stapleton F, Jia T, DePuy V, Bosworth C, Gleeson M, Tan J. The effect of a biweekly novel selenium sulfide-containing topical treatment in symptomatic contact lens wearers: An exploratory study. Ocul Surf 2025; 36:190-197. [PMID: 39894407 DOI: 10.1016/j.jtos.2025.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Revised: 01/20/2025] [Accepted: 01/30/2025] [Indexed: 02/04/2025]
Abstract
PURPOSE To explore effects of topical 1 % selenium sulfide on signs and symptoms in symptomatic contact lens-wearers, in an exploratory 4-month prospective placebo-controlled double-masked randomised trial. METHODS Symptomatic wearers (Contact Lens Dry Eye Questionnaire-8 [CLDEQ-8] score>12) with meibomian gland dysfunction (meibomian gland score (MGS)≤12), were enrolled and received either active (AZR-MD-001-containing 1 % selenium sulfide), or vehicle ointment, to the lower eyelid margin twice-weekly. MGS, meibomian glands-yielding liquid secretion (MGYLS), lipid layer thickness, tear meniscus height, tear break-up time, tear evaporation rate, lid wiper epitheliopathy, CLDEQ-8 and comfortable wear time (CWT) were measured at baseline and to 4-months. Differences between active and placebo were compared to baseline. RESULTS Fourteen participants (5M:9 F, 30.8 ± 13.8 years) completed the study. In the active group, change in MGS from baseline improved by 1-month (mean difference 7.9 ± 8.0, p = 0.03), to 4-months (16.0 ± 11.3, p < 0.01). MGYLS improved from baseline by 1.5-months (4.0 ± 3.3) to 4-months (4.1 ± 4.3, p < 0.01). In the vehicle, change in MGS (12.1 ± 10.7) and MGYLS (3.9 ± 3.2) were improved at 4-months only (p < 0.01). CLDEQ-8 score improved at 1-month and 4-months compared to baseline (-4.4 ± 3.2, -5.1 ± 4.7, p ≤ 0.02) in the active and at 4-months only in the vehicle group (-4.4 ± 6.4, p = 0.02). In the active group, CLDEQ-8 visual function scores improved at 1- and 4-months (p ≤ 0.02) and CWT at 4-months (median 7 vs.10 h, p = 0.025). Other signs were unchanged. CONCLUSIONS This exploratory study indicates that twice-weekly use of AZR-MD-001 ointment can rapidly improve gland patency and secretion in symptomatic contact lens-wearers. AZR-MD-001 reduced changeable/blurry vision and prolonged CWT, suggesting relevant future endpoints.
Collapse
Affiliation(s)
- Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia.
| | - Tianni Jia
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | | | | | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| |
Collapse
|
2
|
Gantz L, Wilks J, Ifrah R. Reproducibility and within-subject variability of HRK-9000A meibography in normal young participants. Ophthalmic Physiol Opt 2025. [PMID: 39757567 DOI: 10.1111/opo.13437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 12/19/2024] [Accepted: 12/19/2024] [Indexed: 01/07/2025]
Abstract
PURPOSE Reliable assessment is critical for diagnosing and managing meibomian gland dysfunction. Multi-functional diagnostic devices, such as meibographers, streamline clinical workflows by integrating multiple ocular assessments. Ensuring reproducibility across examiners is vital for accurate diagnosis and monitoring of treatment. This prospective study determined the inter-examiner reproducibility (IER), inter-rater reproducibility (IRR) and within-subject variability (WSV) of the Huvitz HRK-9000A meibographer. METHODS Meibomian glands (MGs) of both eyelids of healthy participants were captured during the same session by Examiner 1 (E1) and Examiner 2 (E2) in a counter-balanced design. The images were rated offline by E1, E2 and an Independent rater (R1). The inter-examiner reproducibility (IER between E1 vs. E2) and inter-rater reproducibility (IRR between E1 vs. R1 and E2 vs. R1) were determined based on non-parametric Bland-Altman plots, intraclass correlation coefficients (ICCs) and weighted Kappa (κ) values. Within-subject variability (WSV) was determined using ICCs. RESULTS Mean MG loss of the upper (E1: 1.0 ± 0.8 vs. R1: 0.9 ± 0.8, E2: 1.2 ± 0.8 vs. R1: 0.9 ± 0.7) and lower eyelids (E1: 1.9 ± 0.9 vs. R1: 2.1 ± 1.1, E2: 1.5 ± 1.0 vs. R1: 1.8 ± 1.0) of 35 participants (mean age 22 ± 3 years, range 19-30) was significantly correlated (p < 0.001) for all pairs of examiners (E1-E2, E1-R1 and E2-R1), but was significantly different for the upper eyelids of E2 vs. E1 (p < 0.002) and E2 vs. R1 (p < 0.003). Median differences between pairs of raters for both eyelids were close to zero, with >74% of comparisons falling within the interquartile range, except for the upper eyelids of E2 vs. E1 and E2 vs. R1 (63% and 66%, respectively). IRR demonstrated moderate agreement (0.43-0.57) with good reliability (ICC range 0.76-0.86) for the upper eyelids and good agreement (0.60-0.65) with good reliability (ICC range 0.85-0.88) for the lower eyelids. The WSV was excellent (ICCs for repeated measurements > 0.90). CONCLUSIONS The HRK-9000A meibographer demonstrated excellent reliability, with good inter-examiner and inter-rater reproducibility. It is suitable for meibographic assessment, follow-up or treatment.
Collapse
Affiliation(s)
- Liat Gantz
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Judith Wilks
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Reut Ifrah
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| |
Collapse
|
3
|
Farid M, Kim CK, Spina A, Chen KG. Investigating Risk Factors for Meibomian Gland Dysfunction and Loss Among Young Medical Trainees. Cornea 2024:00003226-990000000-00769. [PMID: 39688250 DOI: 10.1097/ico.0000000000003768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 10/28/2024] [Indexed: 12/18/2024]
Abstract
PURPOSE To determine risk factors for meibomian gland disease and associated structural abnormalities in meibography among young medical trainees. METHODS This study included 84 medical students and residents younger than 45 years. All participants completed an ocular history and lifestyle questionnaire and the standardized patient evaluation of eye dryness (SPEED) II questionnaire. Meibomian gland (MG) dropout and structural changes were evaluated using meibography and scored by 2 graders using meiboscores. Statistical analysis aimed to identify MG loss risk factors. RESULTS Eighty-four individuals participated, and 168 meibography images were reviewed. Previous contact lens (CL) use (n = 88) demonstrated increased MG loss (P = 0.007). Correlation analysis revealed positive associations between MG loss and both frequency (Spearman r = 0.212, P = 0.003) and duration (Spearman r = 0.271, P <0.001) of CL use. Eye makeup users (n = 112) showed greater MG loss than nonusers (n = 56, P = 0.030), particularly eyeliner (n = 102) and eyeshadow (n = 100) users showing increased meiboscores (P = 0.020 and P = 0.040, respectively). Self-reported screen time and SPEED II scores did not correlate with meiboscores (P >0.05). CONCLUSIONS In a young trainee population, where age-related factors are reduced, previous CL use and eye makeup use are significant risk factors for MG loss. Frequency and length of CL wear affect MG dropout severity. Eye makeup usage also affected MG loss. Highlighting the incongruence of symptoms to signs, SPEED II scores showed no relationship with MG structural integrity.
Collapse
Affiliation(s)
- Marjan Farid
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA; and
| | - Christine K Kim
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA; and
- University of California, Irvine, School of Medicine, Irvine, CA
| | - Aidin Spina
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA; and
- University of California, Irvine, School of Medicine, Irvine, CA
| | - Katherine G Chen
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA; and
| |
Collapse
|
4
|
Graham AD, Kothapalli T, Wang J, Ding J, Tse V, Asbell PA, Yu SX, Lin MC. A machine learning approach to predicting dry eye-related signs, symptoms and diagnoses from meibography images. Heliyon 2024; 10:e36021. [PMID: 39286076 PMCID: PMC11403426 DOI: 10.1016/j.heliyon.2024.e36021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 08/06/2024] [Accepted: 08/08/2024] [Indexed: 09/19/2024] Open
Abstract
Purpose To use artificial intelligence to identify relationships between morphological characteristics of the Meibomian glands (MGs), subject factors, clinical outcomes, and subjective symptoms of dry eye. Methods A total of 562 infrared meibography images were collected from 363 subjects (170 contact lens wearers, 193 non-wearers). Subjects were 67.2 % female and were 54.8 % Caucasian. Subjects were 18 years of age or older. A deep learning model was trained to take meibography as input, segment the individual MG in the images, and learn their detailed morphological features. Morphological characteristics were then combined with clinical and symptom data in prediction models of MG function, tear film stability, ocular surface health, and subjective discomfort and dryness. The models were analyzed to identify the most heavily weighted features used by the algorithm for predictions. Results MG morphological characteristics were heavily weighted predictors for eyelid notching and vascularization, MG expressate quality and quantity, tear film stability, corneal staining, and comfort and dryness ratings, with accuracies ranging from 65 % to 99 %. Number of visible MG, along with other clinical parameters, were able to predict MG dysfunction, aqueous deficiency and blepharitis with accuracies ranging from 74 % to 85 %. Conclusions Machine learning-derived MG morphological characteristics were found to be important in predicting multiple signs, symptoms, and diagnoses related to MG dysfunction and dry eye. This deep learning method illustrates the rich clinical information that detailed morphological analysis of the MGs can provide, and shows promise in advancing our understanding of the role of MG morphology in ocular surface health.
Collapse
Affiliation(s)
- Andrew D Graham
- Vision Science Group, University of California, Berkeley, United States
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| | - Tejasvi Kothapalli
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, United States
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| | - Jiayun Wang
- Vision Science Group, University of California, Berkeley, United States
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| | - Jennifer Ding
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| | - Vivien Tse
- Vision Science Group, University of California, Berkeley, United States
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| | - Penny A Asbell
- Department of Bioengineering, University of Memphis, United States
| | - Stella X Yu
- International Computer Science Institute, Berkeley, United States
| | - Meng C Lin
- Vision Science Group, University of California, Berkeley, United States
- Clinical Research Center, School of Optometry, University of California, Berkeley, United States
| |
Collapse
|
5
|
Gantz L, Weissman BA, Ifrah R. Complications and compliance in professionally-managed and self-managed contact lenses compared with non-contact lens wearers. PLoS One 2024; 19:e0308538. [PMID: 39240979 PMCID: PMC11379192 DOI: 10.1371/journal.pone.0308538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 07/25/2024] [Indexed: 09/08/2024] Open
Abstract
PURPOSE To test the impact of professional management of soft contact lens wear on symptoms and ocular complications. METHODS Subjective symptoms and ocular complications of soft CL users who did not seek professional follow-up care (self-managed, SM), were compared to users who were prescribed CLs and their care professionally managed in optometry practices (PM), and to a control group of non-CL wearers. Habitual visual acuity, subjective dry-eye symptoms, and corneal abnormalities were assessed in all participants. CL wearers filled-out a usage habits questionnaire, and their CL fit was assessed. Outcomes were compared using Kruskal-Wallis and Chi Squared tests. RESULTS The SM, PM, and non-CL wearers cohorts included 127 (mean age:24.3±5.1, median:23, range:16-45 years,104 female), 132 (mean age:25.5±6.2, median:23, range:18-43 years,103 female), and 56 (mean age:22.3±3.5, median:21, range:18-39 years,36 female) participants, respectively. Meibomian gland dysfunction grade (p = 0.004, p<0.0001), limbal redness (both p = 0.04), corneal neovascularization (both p = 0.003), and papillary conjunctivitis (p<0.0001,p = 0.005) were significantly worse in SM CL wearers compared with both the non-CL wearers and PM CL wearers, respectively. Conjunctival staining was significantly worse in the SM cohort compared with the PM cohort (p = 0.01). 38.6% of the SM compared with 22.8% of the PM CL wearers, had an inappropriate refractive correction (p = 0.006). SM CL wearers wore CLs significantly more years (mean and median 1 year,p = 0.008), for more daily hours (mean and median of 2 hours,p<0.00001), and tended to nap or sleep with their CLs compared with the PM CL wearers (47 vs. 29,p = 0.02). The cohorts did not differ in their subjective symptoms. CONCLUSIONS Complications are significantly more prevalent in SM CL wearers compared with PM CL wearers, and SM CL wearers tend to wear CLs with incorrect powers, and are less compliant with napping or sleeping with the CLs compared with PM CL wearers. These findings emphasize the importance of fitting, patient education and follow-ups in CL wearers.
Collapse
Affiliation(s)
- Liat Gantz
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, ISRAEL
| | - Barry A Weissman
- Southern California College of Optometry at Marshall B. Ketchum University, Fullerton, CA, United States of America
- Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States of America
| | - Reut Ifrah
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, ISRAEL
| |
Collapse
|
6
|
Ifrah R, Quevedo L, Hazrati G, Maman S, Mangisto H, Shmuel E, Gantz L. Contact lens wear and follow-up and its association with signs and symptoms of meibomian gland dysfunction. Ophthalmic Physiol Opt 2024; 44:153-167. [PMID: 37962295 DOI: 10.1111/opo.13247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 10/22/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023]
Abstract
INTRODUCTION This study investigated the equivocal association between contact lens (CL) wear and meibomian gland dysfunction (MGD) by comparing the morphological, functional and subjective outcomes of CL wearers versus control, non-CL wearers. CL wearers were examined as two cohorts based on the annual attendance of follow-up visits (FLU-attended these visits, whereas non-FLU did not). METHODS Habitual logMAR visual acuity, invasive and non-invasive tear break-up time, Schirmer test, Efron grading scales, meibum quality score (MQS), meibum expressibility score (MES), meibomian gland (MG) loss, lid margin abnormalities and subjective dry eye (DE) symptoms were assessed. RESULTS Of the 128 participants, 31 were in the FLU cohort, 43 were in the non-FLU cohort and 54 were controls (mean ages: 22.2 ± 3.1, 23.0 ± 4.6 and 22.3 ± 3.5, respectively). Non-FLU CL wearers had more symptoms than controls (3.7 ± 2.4 vs. 2.3 ± 2.1, p < 0.01). Morphologically, FLU (16.9 ± 8.8%, p = 0.02) and non-FLU (18.6 ± 11.3%, p = 0.001) had more MG loss than controls (11.2 ± 6.8%). Functionally, FLU (0.6 ± 0.7, p = 0.01) and non-FLU (0.8 ± 0.9, p = 0.001) had worse MES than controls (0.2 ± 0.5). FLU and non-FLU were both associated with corneal staining (odds ratio [OR] = 3.42, 95% CI: 1.16-10.11, p = 0.03 and OR = 5.23, 95% CI: 1.89-14.48, p = 0.001, respectively) and MG loss (OR = 10.47, 95% CI: 1.14-96.29, p = 0.04 and OR = 16.63, 95% CI: 1.96-140.86, p = 0.01, respectively). Non-FLU CL wear was also associated with abnormal MQS (OR = 12.87, 95% CI: 1.12-148.41, p = 0.04), conjunctival staining (OR = 12.18, 95% CI: 3.66-40.51, p < 0.001) and lid margin telangiectasia (OR = 3.78, 95% CI: 1.55-9.21, p = 0.003). MGD was three times more prevalent in CL wearers (12%) than in controls (4%). CONCLUSIONS Both CL-wearing cohorts demonstrated significantly more MG abnormalities than controls though the difference was not clinically significant. Non-FLU CL wearers had more DE symptoms. Non-FLU CL wear is an independent predictor for more abnormalities than FLU CL wear, emphasising the importance of follow-ups.
Collapse
Affiliation(s)
- Reut Ifrah
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
- Faculty of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Lluisa Quevedo
- Faculty of Optics and Optometry, Universitat Politècnica de Catalunya, Terrassa, Spain
| | - Gal Hazrati
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Shiran Maman
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Huluager Mangisto
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Eden Shmuel
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| | - Liat Gantz
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| |
Collapse
|
7
|
Zhu Q, Zhang Q, Fu DY, Su G. Polysaccharides in contact lenses: From additives to bulk materials. Carbohydr Polym 2023; 316:121003. [PMID: 37321708 DOI: 10.1016/j.carbpol.2023.121003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/26/2023] [Accepted: 05/07/2023] [Indexed: 06/17/2023]
Abstract
As the number of applications has increased, so has the demand for contact lenses comfort. Adding polysaccharides to lenses is a popular way to enhance comfort for wearers. However, this may also compromise some lens properties. It is still unclear how to balance the variation of individual lens parameters in the design of contact lenses containing polysaccharides. This review provides a comprehensive overview of how polysaccharide addition impacts lens wear parameters, such as water content, oxygen permeability, surface wettability, protein deposition, and light transmittance. It also examines how various factors, such as polysaccharide type, molecular weight, amount, and mode of incorporation into lenses modulate these effects. Polysaccharide addition can improve some wear parameters while reducing others depending on the specific conditions. The optimal method, type, and amount of added polysaccharides depend on the trade-off between various lens parameters and wear requirements. Simultaneously, polysaccharide-based contact lenses may be a promising option for biodegradable contact lenses as concerns regarding environmental risks associated with contact lens degradation continue to increase. It is hoped that this review will shed light on the rational use of polysaccharides in contact lenses to make personalized lenses more accessible.
Collapse
Affiliation(s)
- Qiang Zhu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Qiao Zhang
- Department of Clinical Pharmacy, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China
| | - Ding-Yi Fu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Gaoxing Su
- School of Pharmacy, Nantong University, Nantong 226001, China.
| |
Collapse
|
8
|
Ifrah R, Quevedo L, Gantz L. Repeatability and reproducibility of Cobra HD fundus camera meibography in young adults with and without symptoms of dry eye. Ophthalmic Physiol Opt 2023; 43:183-194. [PMID: 36449267 DOI: 10.1111/opo.13074] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 11/13/2022] [Accepted: 11/14/2022] [Indexed: 12/02/2022]
Abstract
PURPOSE The inter-session repeatability (ISR), inter-examiner reproducibility (IER) and within-subject variability (WSV) of the Cobra HD fundus camera meibographer were examined in participants with and without dry eye symptoms. METHODS Symptoms were determined based on Ocular Surface Disease Index scores (≥13 being considered symptomatic), and subgroups were compared using the Mann-Whitney U-test. Images of meibomian glands (MGs) from the upper and lower right eyelids were captured by two examiners on the same day (S1) to determine IER. One examiner repeated the measurements on a second day (S2) to obtain the ISR. ISR, IER and WSV were calculated using Friedman, correlation tests and Bland and Altman analyses with mean differences (md) and 95% confidence intervals (CIs), within-subject standard deviations (Sw) and intra-class correlation coefficients (ICC). RESULTS The ISR experiment included 72 participants (mean age: 23 ± 5 years, range: 19-43, 36 symptomatic). Mean MG loss of the upper (S1: 13.5 ± 9.5%, S2: 12.8 ± 8.5%) and lower eyelids (S1: 7.5 ± 6.9%, S2: 7.3 ± 6.3%) was not significantly different between sessions for all participants, symptomatic and asymptomatic subgroups for both eyelids. The ISR Sw for the upper and lower eyelids was 1.3% and 1.0%; md was 0.7 ± 3.5% (CI:-6.25% to 7.62%) and 0.1 ± 2.1% (CI: -3.94% to 4.17%), respectively. The IER experiment included 74 participants (mean age: 23 ± 5 years, range: 19-43, 37 symptomatic). Mean MG loss of the upper (Examiner 1: 12.7 ± 8.2%, Examiner 2: 13.1 ± 8.0%) and lower eyelids (Examiner 1: 7.0 ± 6.2%, Examiner 2: 7.4 ± 6.2%) was not significantly different between examiners for all participants, symptomatic and asymptomatic subgroups for both eyelids. The IER ICC values were >0.86 for all conditions, Sw was 1.3% and 1.2%, with a md of -0.4 ± 3.2% (CI: -6.65% to 5.90%) and -0.4 ± 2.9% (CI: -6.15% to 5.31%), respectively. The WSV Sw values were <1.4%, and ICC values were >0.89 for both eyelids, examiners and experimental sessions. CONCLUSIONS The Cobra HD fundus camera demonstrates good repeatability, reproducibility and low WSV, and is a reliable clinical instrument for meibography.
Collapse
Affiliation(s)
- Reut Ifrah
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel.,Faculty of Optics and Optometry, Universitat Politècnica de Catalunya Terrassa, Barcelona, Spain
| | - Lluisa Quevedo
- Faculty of Optics and Optometry, Universitat Politècnica de Catalunya Terrassa, Barcelona, Spain
| | - Liat Gantz
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel
| |
Collapse
|
9
|
García-Marqués JV, Talens-Estarelles C, García-Lázaro S, Cerviño A. The Effects of Soft Contact Lens Wear on The Tear Film and Meibomian Gland Drop-Out and Visibility. Life (Basel) 2022; 12:life12081177. [PMID: 36013356 PMCID: PMC9409842 DOI: 10.3390/life12081177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/30/2022] [Accepted: 07/31/2022] [Indexed: 11/16/2022] Open
Abstract
As contact lens (CL) wear affects the ocular surface, this cross-sectional study aims to assess the effects of soft CL wear and its duration on the tear film and meibomian gland (MG) drop-out and visibility. Thirty non-CL wearers (22.5 ± 2.3 years) and twenty-four soft CL wearers (23.8 ± 2.2 years) participated in this study. The Keratograph 5M was used to assess the ocular surface. CL users were surveyed on years of CL wear and hours per week. MG visibility was assessed using a previously developed method based on analysing pixel intensity of meibographies. The CL group showed higher gland drop-out (p < 0.001) and lower gland visibility (p < 0.022). Gland drop-out was independently associated with CL wear (p = 0.006). When gland drop-out was excluded, the relative energy of pixel intensity values showed an independent association with CL wear (p = 0.005). Prolonged hours of CL wear were associated with higher dry eye symptoms and entropy of MGs (p < 0.029). A reduction in non-invasive keratograph break-up time was associated with using CLs for ≥8 years (p = 0.030). Overall, gland drop-out was higher and gland visibility lower in soft CL wearers. New gland visibility metrics might help to assess MGs in soft CL wearers quickly and objectively.
Collapse
|