1
|
Nouri H, Abtahi SH, Mazloumi M, Samadikhadem S, Arevalo JF, Ahmadieh H. Optical coherence tomography angiography in diabetic retinopathy: A major review. Surv Ophthalmol 2024; 69:558-574. [PMID: 38521424 DOI: 10.1016/j.survophthal.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 02/29/2024] [Accepted: 03/11/2024] [Indexed: 03/25/2024]
Abstract
Diabetic retinopathy (DR) is characterized by retinal vasculopathy and is a leading cause of visual impairment. Optical coherence tomography angiography (OCTA) is an innovative imaging technology that can detect various pathologies and quantifiable changes in retinal microvasculature. We briefly describe its functional principles and advantages over fluorescein angiography and perform a comprehensive review on its clinical applications in the screening or management of people with prediabetes, diabetes without clinical retinopathy (NDR), nonproliferative DR (NPDR), proliferative DR (PDR), and diabetic macular edema (DME). OCTA reveals early microvascular alterations in prediabetic and NDR eyes, which may coexist with sub-clinical neuroretinal dysfunction. Its applications in NPDR include measuring ischemia, detecting retinal neovascularization, and timing of early treatment through predicting the risk of retinopathy worsening or development of DME. In PDR, OCTA helps characterize the flow within neovascular complexes and evaluate their progression or regression in response to treatment. In eyes with DME, OCTA perfusion parameters may be of predictive value regarding the visual and anatomical gains associated with treatment. We further discussed the limitations of OCTA and the benefits of its incorporation into an updated DR severity scale.
Collapse
Affiliation(s)
- Hosein Nouri
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran; School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Seyed-Hossein Abtahi
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Department of Ophthalmology, Labbafinejad Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mehdi Mazloumi
- Eye Research Center, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Sanam Samadikhadem
- Department of Ophthalmology, Imam Hossein Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - J Fernando Arevalo
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| | - Hamid Ahmadieh
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Alotaibi NS. Micro aneurysm detection using optimized residual-based temporal attention Convolutional Neural Network with Inception-V3 transfer learning. Microsc Res Tech 2024; 87:908-921. [PMID: 38168879 DOI: 10.1002/jemt.24478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 10/27/2023] [Accepted: 12/09/2023] [Indexed: 01/05/2024]
Abstract
In this manuscript micro aneurysm detection using residual-based temporal attention Convolutional Neural Network (CNN) with Inception-V3 transfer learning optimized with equilibrium optimization algorithm (MA-RTCNN-Inception V3-EOA) is proposed. The proposed research work contains four phases: (1) pre-processing, (2) segmentation, (3) post-processing, and (4) classification. At first, guided box filtering for contrast enhancement and background exclusion of input image. The proposed MA-RTCNN-Inception V3-EOA based classification framework is implemented in MATLAB using several performances evaluating metrics like precision, sensitivity, f-measure, specificity, accuracy, classification error rate, and Matthews's correlation coefficient and RoC analysis. The experimental outcome demonstrates that the proposed method provides 23.56%, 14.99%, and 21.37% higher accuracy and 31.26%, 57.69%, and 21.14% minimum classification error rate compared to existing methods, such as diabetic retinopathy identification utilizing prognosis of micro aneurysm and early diagnosis for non-proliferative diabetic retinopathy depending on deep learning approaches (DRD-CNN-NPDR), a magnified adaptive feature pyramid network for automatic micro aneurysms identification (MAFPN-AMD-MAFP-Net) respectively. RESEARCH HIGHLIGHTS: Micro aneurysm detection using residual-based temporal attention Convolutional Neural Network (CNN) is proposed. To get rid of the retina background, guided box filtering is applied. COAT is used for segmenting the images into smaller parts RTCNN is used for accurate micro aneurysms disease classification. RT-CNN algorithm successfully identifies the micro aneurysms using EOA.
Collapse
|
3
|
Gao M, Hormel TT, Guo Y, Tsuboi K, Flaxel CJ, Huang D, Hwang TS, Jia Y. Perfused and Nonperfused Microaneurysms Identified and Characterized by Structural and Angiographic OCT. Ophthalmol Retina 2024; 8:108-115. [PMID: 37673397 DOI: 10.1016/j.oret.2023.08.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 08/18/2023] [Accepted: 08/28/2023] [Indexed: 09/08/2023]
Abstract
PURPOSE Microaneurysms (MAs) have distinct, oval-shaped, hyperreflective walls on structural OCT, and inconsistent flow signal in the lumen with OCT angiography (OCTA). Their relationship to regional macular edema in diabetic retinopathy (DR) has not been quantitatively explored. DESIGN Retrospective, cross-sectional study. PARTICIPANTS A total of 99 participants, including 23 with mild, nonproliferative DR (NPDR), 25 with moderate NPDR, 34 with severe NPDR, and 17 with proliferative DR. METHODS We obtained 3 × 3-mm scans with a commercial device (Solix, Visionix/Optovue) in 99 patients with DR. Trained graders manually identified MAs and their location relative to the anatomic layers from cross-sectional OCT. Microaneurysms were first classified as perfused if flow signal was present in the OCTA channel. Then, perfused MAs were further classified into fully and partially perfused MAs based on the flow characteristics in en face OCTA. The presence of retinal fluid based on OCT near MAs was compared between perfused and nonperfused types. We also compared OCT-based MA detection to fundus photography (FP)- and fluorescein angiography (FA)-based detection. MAIN OUTCOME MEASURES OCT-identified MAs can be classified according to colocalized OCTA flow signal into fully perfused, partially perfused, and nonperfused types. Fully perfused MAs may be more likely to be associated with diabetic macular edema (DME) than those without flow. RESULTS We identified 308 MAs (166 fully perfused, 88 partially perfused, 54 nonperfused) in 42 eyes using OCT and OCTA. Nearly half of the MAs identified in this study straddle the inner nuclear layer and outer plexiform layer. Compared with partially perfused and nonperfused MAs, fully perfused MAs were more likely to be associated with local retinal fluid. The associated fluid volumes were larger with fully perfused MAs compared with other types. OCT/OCTA detected all MAs found on FP. Although not all MAs seen with FA were identified with OCT, some MAs seen with OCT were not visible with FA or FP. CONCLUSIONS OCT-identified MAs with colocalized flow on OCTA are more likely to be associated with DME than those without flow. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Min Gao
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
| | - Tristan T Hormel
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
| | - Yukun Guo
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon; Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon
| | - Kotaro Tsuboi
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
| | - Christina J Flaxel
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
| | - David Huang
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon; Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon
| | - Thomas S Hwang
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
| | - Yali Jia
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon; Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon.
| |
Collapse
|
4
|
Huber KL, Stino H, Schlegl T, Steiner I, Nagy G, Niederleithner M, Baumann B, Drexler W, Leitgeb RA, Schmidt-Erfurth U, Schmoll T, Pollreisz A. Microaneurysm detection using high-speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy. Acta Ophthalmol 2023. [PMID: 38126128 DOI: 10.1111/aos.16619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 11/29/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Abstract
PURPOSE To compare detection rates of microaneurysms (MAs) on high-speed megahertz optical coherence tomography angiography (MHz-OCTA), fluorescein angiography (FA) and colour fundus photography (CF) in patients with diabetic retinopathy (DR). METHODS For this exploratory cross-sectional study, MHz-OCTA data were acquired with a swept-source OCT prototype (A-scan rate: 1.7 MHz), and FA and CF imaging was performed using Optos® California. MA count was manually evaluated on en face MHz-OCTA/FA/CF images within an extended ETDRS grid. Detectability of MAs visible on FA images was evaluated on corresponding MHz-OCTA and CF images. MA distribution and leakage were correlated with detectability on OCTA and CF imaging. RESULTS 47 eyes with severe DR (n = 12) and proliferative DR (n = 35) were included. MHz-OCTA and CF imaging detected on average 56% and 36% of MAs, respectively. MHz-OCTA detection rate was significantly higher than CF (p < 0.01). The combination of MHz-OCTA and CF leads to an increased detection rate of 70%. There was no statistically significant association between leakage and MA detectability on OCTA (p = 0.13). For CF, the odds of detecting leaking MAs were significantly lower than non-leaking MAs (p = 0.012). Using MHz-OCTA, detection of MAs outside the ETDRS grid was less likely than MAs located within the ETDRS grid (outer ring, p < 0.01; inner ring, p = 0.028). No statistically significant difference between rings was observed for CF measurements. CONCLUSIONS More MAs were detected on MHz-OCTA than on CF imaging. Detection rate was lower for MAs located outside the macular region with MHz-OCTA and for leaking MAs with CF imaging. Combining both non-invasive modalities can improve MA detection.
Collapse
Affiliation(s)
- Kim Lien Huber
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Heiko Stino
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlegl
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Irene Steiner
- Center for Medical Data Science, Institute of Medical Statistics, Medical University of Vienna, Vienna, Austria
| | - Gergely Nagy
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Michael Niederleithner
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Rainer A Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Ursula Schmidt-Erfurth
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Tilman Schmoll
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
- Carl Zeiss Meditec, Inc., Dublin, California, USA
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
5
|
Waheed NK, Rosen RB, Jia Y, Munk MR, Huang D, Fawzi A, Chong V, Nguyen QD, Sepah Y, Pearce E. Optical coherence tomography angiography in diabetic retinopathy. Prog Retin Eye Res 2023; 97:101206. [PMID: 37499857 DOI: 10.1016/j.preteyeres.2023.101206] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 07/24/2023] [Accepted: 07/25/2023] [Indexed: 07/29/2023]
Abstract
There remain many unanswered questions on how to assess and treat the pathology and complications that arise from diabetic retinopathy (DR). Optical coherence tomography angiography (OCTA) is a novel and non-invasive three-dimensional imaging method that can visualize capillaries in all retinal layers. Numerous studies have confirmed that OCTA can identify early evidence of microvascular changes and provide quantitative assessment of the extent of diseases such as DR and its complications. A number of informative OCTA metrics could be used to assess DR in clinical trials, including measurements of the foveal avascular zone (FAZ; area, acircularity, 3D para-FAZ vessel density), vessel density, extrafoveal avascular zones, and neovascularization. Assessing patients with DR using a full-retinal slab OCTA image can limit segmentation errors and confounding factors such as those related to center-involved diabetic macular edema. Given emerging data suggesting the importance of the peripheral retinal vasculature in assessing and predicting DR progression, wide-field OCTA imaging should also be used. Finally, the use of automated methods and algorithms for OCTA image analysis, such as those that can distinguish between areas of true and false signals, reconstruct images, and produce quantitative metrics, such as FAZ area, will greatly improve the efficiency and standardization of results between studies. Most importantly, clinical trial protocols should account for the relatively high frequency of poor-quality data related to sub-optimal imaging conditions in DR and should incorporate time for assessing OCTA image quality and re-imaging patients where necessary.
Collapse
Affiliation(s)
- Nadia K Waheed
- New England Eye Center, Tufts University School of Medicine, Boston, MA, USA.
| | - Richard B Rosen
- New York Eye and Ear Infirmary of Mount Sinai, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Yali Jia
- School of Medicine, Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - Marion R Munk
- Augenarzt-Praxisgemeinschaft Gutblick AG, Pfäffikon, Switzerland
| | - David Huang
- School of Medicine, Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - Amani Fawzi
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Victor Chong
- Institute of Ophthalmology, University College London, London, UK
| | - Quan Dong Nguyen
- Byers Eye Institute, Stanford University School of Medicine, Stanford, CA, USA
| | - Yasir Sepah
- Byers Eye Institute, Stanford University School of Medicine, Stanford, CA, USA
| | | |
Collapse
|
6
|
Terada N, Murakami T, Ishihara K, Nishikawa K, Kawai K, Tsujikawa A. Quantification of dilated deep capillaries in diabetic retinopathy on optical coherence tomography angiography. Sci Rep 2023; 13:17884. [PMID: 37857682 PMCID: PMC10587140 DOI: 10.1038/s41598-023-44848-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 10/12/2023] [Indexed: 10/21/2023] Open
Abstract
Morphological changes in capillaries are one of major clinical signs in diabetic retinopathy (DR). In this study, we quantified the dilated deep capillaries on optical coherence tomography angiography (OCTA) images. Central 3 × 3 mm en face images were obtained using a swept source OCTA device in 105 eyes of 99 patients with DR. Capillaries with a greater diameter in the deep layers were defined as the dilated deep capillaries, using stepwise image processing. The relative areas of automatically selected capillaries with a great diameter were calculated as the index of the dilated deep capillaries. Most eyes with DR had string-like or dot-like dilated deep capillaries in the OCTA images, which appeared to be dilated capillary segments or microaneurysms histologically. They were distributed more densely in the parafovea than in the central sector, while there were no differences between individual quadrants. The index of the dilated deep capillaries was higher in eyes with DR than in nondiabetic eyes. The index in the central subfield was modestly associated with visual acuity, diabetic macular edema, and proliferative diabetic retinopathy. The quantitative dilated deep capillaries are designated as a biomarker of vision-threatening DR.
Collapse
Affiliation(s)
- Noriko Terada
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Tomoaki Murakami
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Kenji Ishihara
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Keiichi Nishikawa
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kentaro Kawai
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Akitaka Tsujikawa
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Shougoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
7
|
Takamura Y, Yamada Y, Morioka M, Gozawa M, Matsumura T, Inatani M. Turnover of Microaneurysms After Intravitreal Injections of Faricimab for Diabetic Macular Edema. Invest Ophthalmol Vis Sci 2023; 64:31. [PMID: 37856112 PMCID: PMC10593137 DOI: 10.1167/iovs.64.13.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 10/05/2023] [Indexed: 10/20/2023] Open
Abstract
Purpose Microaneurysm (MA) plays an important role in the pathogenesis of diabetic macular edema (DME) progression and response to anti-vascular endothelial growth factor (VEGF) therapy. This study aimed to investigate the effect of faricimab, a bispecific antibody against angiopoietin-2 and VEGF, on the number of MAs and their turnover in the treatment of DME. Methods We included that patients with DME who underwent three monthly injections of faricimab in one eye, with the other eye as control. We examined central retinal thickness (CRT) based on optical coherence tomography (OCT) and best-corrected visual acuity. Turnover, including loss and newly formed MAs, and the total number of MAs were counted based on merged images of the OCT map and fluorescein angiography. Results We enrolled 28 patients with DME. After 3 monthly injections of faricimab, CRT significantly improved, 66.0 ± 16.2% of MAs disappeared, and 6.71 ± 5.6% of new MAs were generated, resulting in total reduction to 40.7 ± 15.2%. In the treated eyes, MA disappearance (P < 0.0001) and turnover (P = 0.007) were significantly greater, and new formation was smaller (P < 0.0001) than in non-treated eyes. The size of the retained MAs decreased after treatment. Microaneurysm turnover was not significantly different between areas with and without edema before treatment. Conclusions In the process of improving edema in DME with faricimab, MAs shrink and disappear, and formation of MAs are inhibited, resulting in decreased total number of MAs. Intravitreal administration of faricimab suppresses vascular permeability and improves vascular structure.
Collapse
Affiliation(s)
- Yoshihiro Takamura
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| | - Yutaka Yamada
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| | - Masakazu Morioka
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| | - Makoto Gozawa
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| | - Takehiro Matsumura
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| | - Masaru Inatani
- Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Eiheiji-cho, Yoshida-gun, Fukui-ken, Japan
| |
Collapse
|
8
|
Hormel TT, Jia Y. OCT angiography and its retinal biomarkers [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:4542-4566. [PMID: 37791289 PMCID: PMC10545210 DOI: 10.1364/boe.495627] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/13/2023] [Accepted: 07/13/2023] [Indexed: 10/05/2023]
Abstract
Optical coherence tomography angiography (OCTA) is a high-resolution, depth-resolved imaging modality with important applications in ophthalmic practice. An extension of structural OCT, OCTA enables non-invasive, high-contrast imaging of retinal and choroidal vasculature that are amenable to quantification. As such, OCTA offers the capability to identify and characterize biomarkers important for clinical practice and therapeutic research. Here, we review new methods for analyzing biomarkers and discuss new insights provided by OCTA.
Collapse
Affiliation(s)
- Tristan T. Hormel
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Yali Jia
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, USA
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
9
|
Nozaki M, Ando R, Kimura T, Kato F, Yasukawa T. The Role of Laser Photocoagulation in Treating Diabetic Macular Edema in the Era of Intravitreal Drug Administration: A Descriptive Review. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1319. [PMID: 37512130 PMCID: PMC10385537 DOI: 10.3390/medicina59071319] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 07/11/2023] [Accepted: 07/15/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: This study aimed to elucidate the role of laser photocoagulation therapy in the treatment of diabetic macular edema (DME) as an alternative to, or in conjunction with, the first-line treatment, anti-vascular endothelial growth factor (VEGF). Materials and Methods: A comprehensive literature search to identify studies that evaluated the efficacy of laser photocoagulation therapy in the management of DME was performed. The relevant findings of the efficacy of focal/grid laser therapy from data in randomized, controlled trials were synthesized, and the potential of new laser technologies, such as navigated laser systems, pattern scan lasers, and subthreshold lasers, was explored. The usefulness of multimodal imaging-guided laser therapy was also evaluated, with a focus on the potential contribution to anti-VEGF therapy. Results: Focal laser photocoagulation targeting microaneurysms remains an effective therapeutic approach to chronic refractory edema, despite the widespread use of anti-VEGF therapy. To achieve the best possible treatment outcomes, precise identification of microaneurysms is essential. This requires the use of multimodal imaging-guided, highly accurate, minimally invasive coagulation techniques. Subthreshold laser therapy can also reduce the frequency of anti-VEGF injections and minimize treatment burden. Conclusions: Further studies are needed to determine the optimal timing and settings for laser photocoagulation therapy and the potential of new laser technologies in the management of DME. Nevertheless, laser photocoagulation therapy plays an important role in the management of DME, in conjunction with anti-VEGF therapy.
Collapse
Affiliation(s)
- Miho Nozaki
- Department of Ophthalmology, Laser Eye Center, Nagoya City University East Medical Center, Nagoya 464-8547, Japan
- Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan
| | - Ryota Ando
- Department of Ophthalmology, Laser Eye Center, Nagoya City University East Medical Center, Nagoya 464-8547, Japan
| | - Toshiya Kimura
- Department of Ophthalmology, Laser Eye Center, Nagoya City University East Medical Center, Nagoya 464-8547, Japan
| | - Fusae Kato
- Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan
- Department of Ophthalmology, Toyota Kosei Hospital, Toyota 470-0396, Japan
| | - Tsutomu Yasukawa
- Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan
| |
Collapse
|
10
|
Ong CJT, Wong MYZ, Cheong KX, Zhao J, Teo KYC, Tan TE. Optical Coherence Tomography Angiography in Retinal Vascular Disorders. Diagnostics (Basel) 2023; 13:diagnostics13091620. [PMID: 37175011 PMCID: PMC10178415 DOI: 10.3390/diagnostics13091620] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 04/28/2023] [Accepted: 05/01/2023] [Indexed: 05/15/2023] Open
Abstract
Traditionally, abnormalities of the retinal vasculature and perfusion in retinal vascular disorders, such as diabetic retinopathy and retinal vascular occlusions, have been visualized with dye-based fluorescein angiography (FA). Optical coherence tomography angiography (OCTA) is a newer, alternative modality for imaging the retinal vasculature, which has some advantages over FA, such as its dye-free, non-invasive nature, and depth resolution. The depth resolution of OCTA allows for characterization of the retinal microvasculature in distinct anatomic layers, and commercial OCTA platforms also provide automated quantitative vascular and perfusion metrics. Quantitative and qualitative OCTA analysis in various retinal vascular disorders has facilitated the detection of pre-clinical vascular changes, greater understanding of known clinical signs, and the development of imaging biomarkers to prognosticate and guide treatment. With further technological improvements, such as a greater field of view and better image quality processing algorithms, it is likely that OCTA will play an integral role in the study and management of retinal vascular disorders. Artificial intelligence methods-in particular, deep learning-show promise in refining the insights to be gained from the use of OCTA in retinal vascular disorders. This review aims to summarize the current literature on this imaging modality in relation to common retinal vascular disorders.
Collapse
Affiliation(s)
- Charles Jit Teng Ong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
| | - Mark Yu Zheng Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
| | - Kai Xiong Cheong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
| | - Jinzhi Zhao
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
| | - Kelvin Yi Chong Teo
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program (EYE ACP), Duke-NUS Medical School, Singapore 169857, Singapore
| | - Tien-En Tan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 168751, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program (EYE ACP), Duke-NUS Medical School, Singapore 169857, Singapore
| |
Collapse
|
11
|
Nakao S, Kaizu Y, Horie J, Wada I, Arima M, Fukuda Y, Ishikawa K, Sonoda KH. VOLUMETRIC THREE-DIMENSIONAL OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF RETINAL NEOVASCULARIZATION IN PROLIFERATIVE DIABETIC RETINOPATHY. Retin Cases Brief Rep 2023; 17:315-320. [PMID: 34310414 DOI: 10.1097/icb.0000000000001183] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate structural and angiographic neovascularization in patients with proliferative diabetic retinopathy using volumetric three-dimensional optical coherence tomography angiography (OCTA). METHODS This prospective, observational cross-sectional study included 29 eyes of 27 patients with proliferative diabetic retinopathy. The angiogenic structure, feeding vessel (epicenter), flow volume, and flow volume density of the neovasculatures were evaluated using three-dimensional OCTA imaging. The flow area and the flow area density were also measured using en face OCTA imaging. RESULTS Sites of neovascularization were imaged successfully in 17 of the 29 eyes (58.6%). Three proposed types of neovascularization were identified on the basis of structural features seen on the three-dimensional OCTA images. Neovascularization of the adhesion type (9 of 17, 52.9%) adhered to the retinal vasculature. Those of the traction type (5 of 17, 29.4%) were partially separated from the retinal vascular plexus. Those of the mushroom type (3 of 17, 17.6%) were connected to the retinal vasculature by several epicenters. There was a significant difference between highly leaky (active) and faintly leaky (inactive) neovascularization for flow volume density, but not for flow area, flow volume, or flow area density ( P = 0.01, 0.9, 0.6, and 0.1, respectively). CONCLUSION Volumetric three-dimensional OCTA revealed three types of neovascularization in proliferative diabetic retinopathy and may be useful for assessing neovascular activity and planning vitrectomies.
Collapse
Affiliation(s)
- Shintaro Nakao
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
- Department of Ophthalmology, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan; and
| | - Yoshihiro Kaizu
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Juun Horie
- Ophthalmic Equipment Business Planning Department, Canon Inc, Tokyo, Japan
| | - Iori Wada
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Mitsuru Arima
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yosuke Fukuda
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
- Department of Ophthalmology, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan; and
| | - Keijiro Ishikawa
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Koh-Hei Sonoda
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
12
|
Hatano M, Higashijima F, Yoshimoto T, Ogata T, Ohta M, Kobayashi Y, Wakuta M, Yanai R, Kimura K. Evaluation of microaneurysms as predictors of therapeutic response to anti-VEGF therapy in patients with DME. PLoS One 2022; 17:e0277920. [PMID: 36441722 PMCID: PMC9704562 DOI: 10.1371/journal.pone.0277920] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 10/25/2022] [Indexed: 11/29/2022] Open
Abstract
Administration of intravitreal anti-vascular endothelial growth factor (anti-VEGF) therapy is the first-line therapy for diabetic macular oedema (DME). However, some patients show no or insufficient response to repeated anti-VEGF injections. Therefore, it is necessary to identify factors that can predict this resistance against anti-VEGF treatment. Presence of microaneurysms (MAs) is a predictor of the development and progression of DME, but its relationship with the treatment response to the anti-VEGF agents is not well known. Therefore, we aimed to elucidate the relationship between the distribution of MAs and the response to anti-VEGF therapy in patients with DME. The number of MAs was measured before anti-VEGF therapy in each region using fluorescein angiography, indocyanine green angiography (IA), and optical coherence tomography angiography. Patients with DME were divided into the responder and non-responder groups after three loading phases. Differences in the distribution of MAs between the groups were investigated. Pre-treatment IA revealed more MAs in the nasal area in the non-responder group than in the responder group (10.7 ± 10.7 and 5.7 ± 5.7, respectively, in the nasal macula) (1.4 ± 2.1 and 0.4 ± 0.7, respectively, in the nasal fovea). Whereas, pre-treatment FA and OCTA could not reveal significantly difference between the groups. Detection of MAs in the nasal macula using pre-treatment IA may indicate resistance to anti-VEGF therapy. We recommend the clinicians confirm the presence of MAs in the nasal macula, as shown by IA, as a predictor of therapeutic response to anti-VEGF therapy in patients with treatment naive DME.
Collapse
Affiliation(s)
- Makoto Hatano
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Fumiaki Higashijima
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Takuya Yoshimoto
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Tadahiko Ogata
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Manami Ohta
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Yuka Kobayashi
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Makiko Wakuta
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Ryoji Yanai
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
| | - Kazuhiro Kimura
- Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi, Japan
- * E-mail:
| |
Collapse
|
13
|
Crincoli E, Colantuono D, Zhao Z, Souied EH, Miere A. Optical coherence tomography angiography for quantitative microvascular assessment in diabetic retinopathy: inter-device and intra-device agreement and correlation with clinical staging. Acta Diabetol 2022; 59:1219-1227. [PMID: 35790606 DOI: 10.1007/s00592-022-01921-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 06/10/2022] [Indexed: 11/01/2022]
Abstract
AIM To compare acquisitions from single-volume Solix protocol (V1), multi-volume averaged Solix protocol (V4), and AngioVue in patients with diabetic retinopathy (DR) to assess differences in quantitative parameters introduced by high-speed scanning and averaging. METHODS Thirty-eight diabetic patients were divided into 4 groups showing either no sign, mild, moderate, or severe DR at fundus examination. For optical coherence tomography angiography (OCTA) acquisitions both AngioVue, Solix V1, and V4 were used on each patient. Outcome measures were macular perfusion density (PD), vessel length density (VLD), and vessel density index (VDI) for both superficial capillary plexus (SCP) and deep capillary plexus (DCP) and flow deficits (FD) in the choriocapillaris (CC). RESULTS Our study revealed a good agreement in SCP parameters measured with all 3 devices. DCP measurements with Solix V1 showed moderate agreement with V4 and poor agreement with AngioVue measurements. Inter-device agreement in CC-FD assessment was relatively poor considering all 3 devices. The averaging process led to an underestimation of DCP and SCP parameters in all stages of DR (more evident in mild DR). AngioVue measurements compared to Solix V1 led to overestimation of SCP-PD (more pronounced in severe DR patients) and of DCP parameters (more evidently in moderate DR). The regression model derived from Solix V1 parameters was the best for categorization into the different stages. CONCLUSIONS Averaging and high-speed scanning introduce changes in OCTA quantitative parameters in DR. Solix V1 is the most suitable for early diagnosis of DR, while averaged protocol could be the preferred choice in advanced stages of the disease.
Collapse
Affiliation(s)
- Emanuele Crincoli
- Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, 40, avenue de Verdun, 94100, Créteil, France
- Catholic University of "Sacro Cuore", Largo Francesco Vito 1, 00168, Rome, Italy
| | - Donato Colantuono
- Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, 40, avenue de Verdun, 94100, Créteil, France
| | - Zhanlin Zhao
- Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, 40, avenue de Verdun, 94100, Créteil, France
| | - Eric H Souied
- Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, 40, avenue de Verdun, 94100, Créteil, France
| | - Alexandra Miere
- Department of Ophthalmology, Centre Hospitalier Intercommunal de Créteil, 40, avenue de Verdun, 94100, Créteil, France.
| |
Collapse
|
14
|
Kaizu Y, Nakao S, Soda T, Horie J, Wada I, Yamaguchi M, Takeda A, Sonoda KH. Longer Interscan Times in OCT Angiography Detect Slower Capillary Flow in Diabetic Retinopathy. OPHTHALMOLOGY SCIENCE 2022; 2:100181. [PMID: 36245749 PMCID: PMC9560536 DOI: 10.1016/j.xops.2022.100181] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 06/07/2022] [Accepted: 06/07/2022] [Indexed: 12/03/2022]
Abstract
Purpose To investigate the detection of slower retinal capillary blood flow using commercial OCT angiography (OCTA) with a longer interscan time in diabetic retinopathy (DR). Design Observational, prospective, cross-sectional study. Participants A total of 62 eyes from 39 subjects with diabetes mellitus and 10 eyes from 9 healthy subjects. Methods Commercial spectral domain-OCT was used to obtain 3 × 3-mm fovea-centered OCTA images of all eyes with 3 different interscan times (4.3, 5.7, and 8.6 ms). For each interscan time, OCTA imaging was performed 5 consecutive times, and a ×5 averaged image was obtained. Capillary flow density and visualization of retinal capillaries in the superficial and deep capillary plexuses (SCPs and DCPs, respectively) were compared between the 3 averaged images from the 3 different interscan times. Main Outcome Measures Capillary flow density and visualization of foveal capillaries in 3 images with different interscan times. Results Forty-five eyes of 34 patients were analyzed. There was no significant difference in the flow density of the SCP and DCP between the 3 images with different interscan times in all the DR stages. Some capillaries including microaneurysms that could not be observed at 4.3 ms could be observed at 5.7 or 8.6 ms. There were significantly more capillaries with difference points between the 3 images in the group with DR than in the group without DR (P < 0.01). The morphology of some microaneurysms also changed with longer interscan times. Conclusions OCTA with longer interscan times revealed slower flow points in capillaries and more accurate visualization and morphology of microaneurysms in DR.
Collapse
Affiliation(s)
- Yoshihiro Kaizu
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Shintaro Nakao
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
- Department of Ophthalmology, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan
- Clinical Research Institute, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan
- Correspondence: Shintaro Nakao, MD, PhD, National Hospital Organization, Kyushu Medical Center, 1-8-1 Jigyohama, Chuo-Ku, Fukuoka 810-8563, Japan.
| | - Tomomi Soda
- Department of Ophthalmology, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan
- Clinical Research Institute, National Hospital Organization, Kyushu Medical Center, Fukuoka, Japan
| | | | - Iori Wada
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Muneo Yamaguchi
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Atsunobu Takeda
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Koh-Hei Sonoda
- Department of Ophthalmology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
15
|
Zhang Q, Sampani K, Xu M, Cai S, Deng Y, Li H, Sun JK, Karniadakis GE. AOSLO-net: A Deep Learning-Based Method for Automatic Segmentation of Retinal Microaneurysms From Adaptive Optics Scanning Laser Ophthalmoscopy Images. Transl Vis Sci Technol 2022; 11:7. [PMID: 35938881 PMCID: PMC9366726 DOI: 10.1167/tvst.11.8.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 07/02/2022] [Indexed: 11/24/2022] Open
Abstract
Purpose Accurate segmentation of microaneurysms (MAs) from adaptive optics scanning laser ophthalmoscopy (AOSLO) images is crucial for identifying MA morphologies and assessing the hemodynamics inside the MAs. Herein, we introduce AOSLO-net to perform automatic MA segmentation from AOSLO images of diabetic retinas. Method AOSLO-net is composed of a deep neural network based on UNet with a pretrained EfficientNet as the encoder. We have designed customized preprocessing and postprocessing policies for AOSLO images, including generation of multichannel images, de-noising, contrast enhancement, ensemble and union of model predictions, to optimize the MA segmentation. AOSLO-net is trained and tested using 87 MAs imaged from 28 eyes of 20 subjects with varying severity of diabetic retinopathy (DR), which is the largest available AOSLO dataset for MA detection. To avoid the overfitting in the model training process, we augment the training data by flipping, rotating, scaling the original image to increase the diversity of data available for model training. Results The validity of the model is demonstrated by the good agreement between the predictions of AOSLO-net and the MA masks generated by ophthalmologists and skillful trainees on 87 patient-specific MA images. Our results show that AOSLO-net outperforms the state-of-the-art segmentation model (nnUNet) both in accuracy (e.g., intersection over union and Dice scores), as well as computational cost. Conclusions We demonstrate that AOSLO-net provides high-quality of MA segmentation from AOSLO images that enables correct MA morphological classification. Translational Relevance As the first attempt to automatically segment retinal MAs from AOSLO images, AOSLO-net could facilitate the pathological study of DR and help ophthalmologists make disease prognoses.
Collapse
Affiliation(s)
- Qian Zhang
- Division of Applied Mathematics, Brown University, Providence, RI, USA
| | - Konstantina Sampani
- Beetham Eye Institute, Joslin Diabetes Center, Department of Medicine and Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - Mengjia Xu
- Division of Applied Mathematics, Brown University, Providence, RI, USA
- McGovern Institute for Brain Research, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Shengze Cai
- Division of Applied Mathematics, Brown University, Providence, RI, USA
| | - Yixiang Deng
- School of Engineering, Brown University, Providence, RI, USA
| | - He Li
- School of Engineering, Brown University, Providence, RI, USA
| | - Jennifer K. Sun
- Beetham Eye Institute, Joslin Diabetes Center, Department of Medicine and Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | - George Em Karniadakis
- Division of Applied Mathematics and School of Engineering, Brown University, Providence, RI, USA
| |
Collapse
|
16
|
Morphology and fluorescein leakage in diabetic retinal microaneurysms: a study using multiple en face OCT angiography image averaging. Graefes Arch Clin Exp Ophthalmol 2022; 260:3517-3523. [PMID: 35665851 DOI: 10.1007/s00417-022-05713-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 05/12/2022] [Accepted: 05/27/2022] [Indexed: 01/07/2023] Open
Abstract
PURPOSE To investigate the relevance of microaneurysm morphology in optical coherence tomography angiography (OCTA) image averaging and fluorescein leakage in diabetic retinopathy (DR). METHODS In 38 consecutive patients with DR, ten consecutive 3- × 3-mm fovea-centered OCTA (HS100, Canon Inc., Tokyo, Japan) and fluorescein angiography (FA) were performed, and averaged OCTA images were created based on the 10 images. After detecting all microaneurysms in FA images, the morphology was classified into four types (focal bulge, saccular/pedunculated, fusiform, and mixed) using averaged OCTA images. The correlation between microaneurysm leakage in FA, retinopathy stage, and microaneurysm morphology was estimated. RESULTS Thirty-eight eyes (50.0%) of the 33 patients were available for analysis, and 370 (63.5%) of the 583 FA-detected microaneurysms were morphologically classifiable (focal bulge, 46; saccular/pedunculated, 143; fusiform, 29; and mixed, 152) in OCTA. There was a significant correlation between stage and percentage of microaneurysm morphology and between morphology and the presence of leakage (P < 0.0001 and P < 0.01, respectively). The proportion of focal bulges decreased with stage progression, while the other three types increased with stage progression. The percentage of FA leakage for focal bulge, saccular/pedunculated, fusiform, and mixed was 41.3%, 66.4%, 82.8%, and 66.4%, respectively, and the fusiform type showed significant FA leakage. CONCLUSION Microaneurysm morphology is correlated with the DR stage and FA leakage. Microaneurysm morphology recognition using OCTA image averaging may be useful for the clinical evaluation of DR.
Collapse
|
17
|
Sampson DM, Dubis AM, Chen FK, Zawadzki RJ, Sampson DD. Towards standardizing retinal optical coherence tomography angiography: a review. LIGHT, SCIENCE & APPLICATIONS 2022; 11:63. [PMID: 35304441 PMCID: PMC8933532 DOI: 10.1038/s41377-022-00740-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 02/01/2022] [Accepted: 02/14/2022] [Indexed: 05/11/2023]
Abstract
The visualization and assessment of retinal microvasculature are important in the study, diagnosis, monitoring, and guidance of treatment of ocular and systemic diseases. With the introduction of optical coherence tomography angiography (OCTA), it has become possible to visualize the retinal microvasculature volumetrically and without a contrast agent. Many lab-based and commercial clinical instruments, imaging protocols and data analysis methods and metrics, have been applied, often inconsistently, resulting in a confusing picture that represents a major barrier to progress in applying OCTA to reduce the burden of disease. Open data and software sharing, and cross-comparison and pooling of data from different studies are rare. These inabilities have impeded building the large databases of annotated OCTA images of healthy and diseased retinas that are necessary to study and define characteristics of specific conditions. This paper addresses the steps needed to standardize OCTA imaging of the human retina to address these limitations. Through review of the OCTA literature, we identify issues and inconsistencies and propose minimum standards for imaging protocols, data analysis methods, metrics, reporting of findings, and clinical practice and, where this is not possible, we identify areas that require further investigation. We hope that this paper will encourage the unification of imaging protocols in OCTA, promote transparency in the process of data collection, analysis, and reporting, and facilitate increasing the impact of OCTA on retinal healthcare delivery and life science investigations.
Collapse
Affiliation(s)
- Danuta M Sampson
- Surrey Biophotonics, Centre for Vision, Speech and Signal Processing and School of Biosciences and Medicine, The University of Surrey, Guildford, GU2 7XH, UK.
| | - Adam M Dubis
- NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Trust and UCL Institute of Ophthalmology, London, EC1V 2PD, UK
| | - Fred K Chen
- Centre for Ophthalmology and Visual Science (incorporating Lions Eye Institute), The University of Western Australia, Nedlands, Western Australia, 6009, Australia
- Department of Ophthalmology, Royal Perth Hospital, Perth, Western Australia, 6000, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Victoria, 3002, Australia
| | - Robert J Zawadzki
- Department of Ophthalmology & Vision Science, University of California Davis, Sacramento, CA, 95817, USA
| | - David D Sampson
- Surrey Biophotonics, Advanced Technology Institute, School of Physics and School of Biosciences and Medicine, University of Surrey, Guildford, Surrey, GU2 7XH, UK
| |
Collapse
|
18
|
Abstract
Diabetic retinopathy is a microvascular pathology, which is the most common complication of diabetes mellitus. Improvement of instrumental diagnostics of retinal pathologies has contributed to identification of various phenotypes of the progression of ocular fundus pathology in diabetes based on specific changes in the retina - biomarkers. In particular, microaneurysms initially described in diabetes, which are a manifestation of a wide range of systemic pathologies and retinal diseases, are an indicator of the severity of diabetic retinopathy. Dynamic changes in the number of microaneurysms are a confirmed prognostic biomarker of clinically significant macular edema. In diabetic retinopathy, microaneurysms are one of the earliest recognizable signs, and the dynamic of their formation and disappearance may serve as a predictor for the disease progression. This literature review presents the characteristics of microaneurysms based on various imaging techniques, and analyses the link between structural features and dynamic changes in microaneurysms, and progression of diabetic retinopathy.
Collapse
|
19
|
Kawai K, Uji A, Murakami T, Kadomoto S, Oritani Y, Dodo Y, Muraoka Y, Akagi T, Miyata M, Tsujikawa A. IMAGE EVALUATION OF ARTIFICIAL INTELLIGENCE-SUPPORTED OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING USING OCT-A1 DEVICE IN DIABETIC RETINOPATHY. Retina 2021; 41:1730-1738. [PMID: 33395219 DOI: 10.1097/iae.0000000000003101] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
PURPOSE To investigate the effect of denoise processing by artificial intelligence (AI) on the optical coherence tomography angiography (OCTA) images in eyes with retinal lesions. METHODS Prospective, observational, cross-sectional study. Optical coherence tomography angiography imaging of a 3 × 3-mm area involving the lesions (neovascularization, intraretinal microvascular abnormality, and nonperfusion area) was performed five times using OCT-HS100 (Canon, Tokyo, Japan). We acquired AI-denoised OCTA images and averaging OCTA images generated from five cube scan data through built-in software. Main outcomes were image acquisition time and the subjective assessment by graders and quantitative measurements of original OCTA images, averaging OCTA images, and AI-denoised OCTA images. The parameters of quantitative measurements were contrast-to-noise ratio, vessel density, vessel length density, and fractal dimension. RESULTS We studied 56 eyes from 43 patients. The image acquisition times for the original, averaging, and AI-denoised images were 31.87 ± 12.02, 165.34 ± 41.91, and 34.37 ± 12.02 seconds, respectively. We found significant differences in vessel density, vessel length density, fractal dimension, and contrast-to-noise ratio (P < 0.001) between original, averaging, and AI-denoised images. Both subjective and quantitative evaluations showed that AI-denoised OCTA images had less background noise and depicted vessels clearly. In AI-denoised images, the presence of fictional vessels was suspected in 2 of the 35 cases of nonperfusion area. CONCLUSION Denoise processing by AI improved the image quality of OCTA in a shorter time and allowed more accurate quantitative evaluation.
Collapse
Affiliation(s)
- Kentaro Kawai
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Nakai M, Iwami H, Fukuyama H, Gomi F. Visualization of microaneurysms in macular telangiectasia type 1 on optical coherence tomography angiography before and after photocoagulation. Graefes Arch Clin Exp Ophthalmol 2020; 259:1513-1520. [PMID: 33006655 PMCID: PMC8166721 DOI: 10.1007/s00417-020-04953-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 09/09/2020] [Accepted: 09/21/2020] [Indexed: 12/02/2022] Open
Abstract
Purpose To evaluate changes in the visualization of microaneurysms (MAs) in cases of macular telangiectasia (Mac Tel) type 1 on optical coherence tomography angiography (OCTA) before and after treatment with direct photocoagulation and to evaluate their relationship with treatment efficacy. Methods The study included 12 eyes from 12 patients (8 men, 4 women; mean age 72.1 years) with Mac Tel type 1 accompanied by cystoid macular edema. OCTA for the evaluation of MAs was performed before and 15 min and 6, 12, and 24 weeks after photocoagulation. The best-corrected visual acuity (BCVA) and central retinal thickness (CRT) were also evaluated. Results A total of 73 MAs were detected within the areas of macular edema on OCTA, and 39 of these underwent photocoagulation. At 15 min after treatment, 17 MAs were no longer visible on OCTA. At 6 weeks, two MAs had reappeared, whereas five additional MAs were no longer visible. The CRT in eyes with resolved MA was significantly less than that in eyes with persistent MAs (p = 0.016). At 24 weeks, seven eyes had no visible MAs, and the BCVA was not significantly different from baseline. Conclusion OCTA can monitor changes in the visualization of MAs associated with Mac Tel type 1 after direct photocoagulation. Eyes in which MAs disappeared after treatment could recover from cystoid macular edema.
Collapse
Affiliation(s)
- Mitsuko Nakai
- Department of Ophthalmology, Hyogo College of Medicine, 1-1, Mukogawa, Nishinomiya, 663-8501, Japan
| | - Hisashi Iwami
- Department of Ophthalmology, Hyogo College of Medicine, 1-1, Mukogawa, Nishinomiya, 663-8501, Japan
| | - Hisashi Fukuyama
- Department of Ophthalmology, Hyogo College of Medicine, 1-1, Mukogawa, Nishinomiya, 663-8501, Japan
| | - Fumi Gomi
- Department of Ophthalmology, Hyogo College of Medicine, 1-1, Mukogawa, Nishinomiya, 663-8501, Japan.
| |
Collapse
|
21
|
Kraker JA, Omoba BS, Cava JA, Gilat Schmidt T, Chui TY, Rosen RB, Kim JE, Carroll J, Linderman RE. Assessing the Influence of OCT-A Device and Scan Size on Retinal Vascular Metrics. Transl Vis Sci Technol 2020; 9:7. [PMID: 33101784 PMCID: PMC7545061 DOI: 10.1167/tvst.9.11.7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 09/01/2020] [Indexed: 12/12/2022] Open
Abstract
Purpose The purpose of this study was to investigate the effect of device and scan size on quantitative optical coherence tomography angiography (OCT-A) metrics. Methods The 3 × 3 mm scans from Optovue AngioVue and Zeiss AngioPlex systems were included for 18 eyes of 18 subjects without ocular pathology. The foveal avascular zone (FAZ) was segmented manually by two observers, from which estimates of FAZ area (using both the nominal image scale and the axial length corrected image scale) and acircularity were derived. Three scan sizes (3 mm, 6 mm HD, and 8 mm) from the AngioVue system were included for 15 eyes of 15 subjects without ocular pathology. For each subject, larger image sizes were resized to the same resolution as 3 × 3 mm scans, aligned, then cropped to a common area. FAZ area, FAZ acircularity, average and total parafoveal intercapillary area, vessel density, and vessel end points were computed. Results Between the devices used here, there were no significant differences in FAZ acircularity (P = 0.88) or FAZ area using scaled (P = 0.11) or unscaled images (P = 0.069). Although there was no significant difference in FAZ area across scan sizes (P = 0.30), vessel morphometry metrics were all significantly influenced by scan size. Conclusions The scan devices and sizes used here do not affect FAZ area measures derived from manual segmentations. In contrast, vessel morphometry metrics are affected by scan size. As individual differences in axial length induce differences in absolute scan size, extreme care should be taken when interpreting metrics of vessel morphometry, both between and within OCT-A devices. Translational Relevance A better characterization of the confounds surrounding OCT-A retinal vasculature metrics can lead to improved application of these metrics as biomarkers for retinal and systemic diseases.
Collapse
Affiliation(s)
- Jessica A Kraker
- School of Medicine, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Bisola S Omoba
- School of Medicine, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Jenna A Cava
- Department of Ophthalmology and Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Taly Gilat Schmidt
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA
| | - Toco Y Chui
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, NY, USA
- Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Richard B Rosen
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, NY, USA
- Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Judy E Kim
- Department of Ophthalmology and Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Joseph Carroll
- Department of Ophthalmology and Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, USA
- Department of Cell Biology, Neurobiology, and Anatomy, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Rachel E Linderman
- Department of Cell Biology, Neurobiology, and Anatomy, Medical College of Wisconsin, Milwaukee, WI, USA
| |
Collapse
|
22
|
Detection rate of diabetic macular microaneurysms comparing dye-based angiography and optical coherence tomography angiography. Sci Rep 2020; 10:16274. [PMID: 33005009 PMCID: PMC7530679 DOI: 10.1038/s41598-020-73516-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 09/17/2020] [Indexed: 01/13/2023] Open
Abstract
Diabetic maculopathy (DM) is a microvascular dysfunction clinically characterized by microaneurysms (MA) leading to edema and central visual deprivation. This prospective explorative study investigated 27 eyes of 17 patients with DM by fluorescein/indocyanine green angiography (FA/ICGA; SPECTRALIS HRA-OCT, Heidelberg Engineering) and by swept source-optical coherence tomography angiography (SS-OCTA; DRI-OCT Triton Plus, Topcon) to identify clinically relevant MAs. The SS-OCTA cubes were split into the superficial capillary plexus (SCP) and the deep capillary plexus (DCP) according to the automated segmentation. The images of all modalities were superimposed for alignment by an Early Treatment Diabetic Retinopathy Study grid overlay and compared to each other. In total, the mean number of MAs in FA was 33.4 ± 22 (standard deviation) (median 27.5 [q1:21.75;q3:38.25]), in ICGA 24.9 ± 16.9 (17.5 [14;35]), in the SCP 6.5 ± 3.7 (5.5 [3.75;9.25]) and in the DCP 18.1 ± 10.5 (18.5 [10.75;23.5]). Mixed effects models between ICGA and the DCP were borderline significant (p = 0.048; 95% confidence interval 0.21 to 13.49), whereas all other imaging methods differed significantly. Quantitative analysis of MAs in DM showed a plausible agreement between ICGA and the DCP in SS-OCTA. These findings contribute to the imaging methodology in DM.
Collapse
|
23
|
Optical coherence tomography angiography in diabetes: focus on microaneurysms. Eye (Lond) 2020; 35:142-148. [PMID: 32887935 DOI: 10.1038/s41433-020-01173-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 08/18/2020] [Accepted: 08/25/2020] [Indexed: 01/12/2023] Open
Abstract
The introduction of optical coherence tomography angiography (OCTA) has remarkably expanded our knowledge of the ocular vascular alterations occurring in diabetes. In this article, a review of the prominent OCTA findings in diabetes is followed by a description of salient histological and anatomical features of microaneurysms, essential for the proper interpretation of in vivo imaging of these retinal vascular abnormalities. The recent employment of a three-dimensional (3D) visualization in OCTA imaging is also discussed. The latter imaging technique has granted a detailed characterization of microaneurysms in vivo.
Collapse
|
24
|
Parrulli S, Corvi F, Cozzi M, Monteduro D, Zicarelli F, Staurenghi G. Microaneurysms visualisation using five different optical coherence tomography angiography devices compared to fluorescein angiography. Br J Ophthalmol 2020; 105:526-530. [PMID: 32527718 PMCID: PMC8005788 DOI: 10.1136/bjophthalmol-2020-316817] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 05/25/2020] [Indexed: 01/08/2023]
Abstract
Background To compare fluorescein angiography (FA) and five different optical coherence tomography angiography (OCTA) devices and to test their reproducibility in the evaluation of retinal microaneurysms (MAs) secondary to diabetic retinopathy (DR). Methods On the same day, patients with DR were imaged with FA and five OCTA devices: prototype Spectralis OCTA, prototype PlexElite, RTVue XR Avanti, AngioPlex and DRI OCT Triton. For all OCTA devices, a 3×3 volume scan pattern was performed. MAs were evaluated for the superficial capillary plexus (SCP) and deep capillary plexus (DCP). Results Twenty eyes of 15 patients with DR were included. FA counted a significantly higher number of MAs compared to OCTA devices. Spectralis OCTA obtained a significantly higher number of MAs compared to PlexElite, RTVue XR Avanti, AngioPlex and DRI OCT Triton (p<0.0001). PlexElite and AngioPlex showed a greater number of MAs in the SCP, Spectralis OCTA, RTVue XR Avanti and DRI OCT Triton in the DCP. Higher sensitivity (43.3%) but lowest specificity (54.4%) was observed for Spectralis OCTA compared to other devices. The higher specificity (78.5%) and positive predictive value (83.3%) were observed for DRI OCT Triton. Conclusions FA remains the best imaging modality to visualise retinal MAs. Spectralis OCTA was able to detect more MAs compared to other devices, likely due to the higher number of B-scans in the scanned area as well as due to the higher number of repeated B-scans. The high variability between OCTA devices should be taken into account for future clinical trials as in clinical practice.
Collapse
Affiliation(s)
- Salvatore Parrulli
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| | - Federico Corvi
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| | - Mariano Cozzi
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| | - Davide Monteduro
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| | - Federico Zicarelli
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| | - Giovanni Staurenghi
- Eye Clinic, Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan, Milano, Italy
| |
Collapse
|
25
|
Jung JJ, Yu DJG, Zeng A, Chen MH, Shi Y, Nassisi M, Marion KM, Sadda SR, Hoang QV. Correlation of Quantitative Measurements with Diabetic Disease Severity Using Multiple En Face OCT Angiography Image Averaging. Ophthalmol Retina 2020; 4:1069-1082. [PMID: 32389888 DOI: 10.1016/j.oret.2020.04.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 04/22/2020] [Accepted: 04/30/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To evaluate the effect of averaging en face OCT angiography (OCTA) images on quantitative measurements of the retinal microvasculature and their correlation to diabetic retinopathy (DR) disease severity. DESIGN Cross-sectional cohort study. PARTICIPANTS One hundred five eyes (65 patients) comprising 28 eyes from 19 healthy, aged-matched control participants, 14 eyes from 9 diabetics without DR, and 63 eyes from 37 diabetics with varying levels of DR. METHODS Spectral-domain CIRRUS 5000 (Carl Zeiss Meditec, Dublin, CA) OCTA images with no macular edema or significant motion artifact were acquired 5 times with the 3 × 3-mm scan pattern. En face images of the superficial retinal layer (SRL) and deep retinal layer were registered and averaged. Vessel length density (VLD), perfusion density (PD), and foveal avascular zone (FAZ) parameters were measured on averaged versus single OCTA images. MAIN OUTCOME MEASURES Univariate and multivariate linear regression correlated quantitative metrics to DR severity and best-corrected visual acuity (BCVA). RESULTS Eighty-four eyes (55 patients) met the inclusion criteria. Almost uniformly, lower VLD and PD parameters were associated significantly with worse DR severity and BCVA. Multivariate linear regression for DR severity resulted in an R2 value of 0.82 and 0.77 for single and averaged groups, respectively. No variables remained associated significantly with DR severity in multivariate analysis with single images, but in averaged images, increased superior SRL PD significantly predicted worse DR severity (coefficient, 52.7; P = 0.026). Multivariate linear regression for BCVA had an R2 value of 0.42 and 0.47 for single and averaged groups, respectively. Foveal avascular zone size was not associated with DR severity when single OCTA images (P = 0.98) were considered, but was highly associated when using averaged images (coefficient, 6.18; P < 0.001). Foveal avascular zone size was predictive for logarithm of the minimum angle of resolution BCVA with averaged images (0.21; P = 0.004), but not with single images (P = 0.31). CONCLUSIONS Averaging of en face OCTA images improves the visualization of capillaries, particularly increasing the clarity of the FAZ borders, and therefore improves the correlation of vessel density and FAZ-specific parameters to DR severity and BCVA.
Collapse
Affiliation(s)
- Jesse J Jung
- East Bay Retina Consultants, Inc, Oakland, California; Department of Ophthalmology, University of California, San Francisco, San Francisco, California.
| | - Daryle Jason G Yu
- Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore, Republic of Singapore
| | - Anne Zeng
- East Bay Retina Consultants, Inc, Oakland, California
| | | | - Yue Shi
- Doheny Eye Institute, Los Angeles, California
| | - Marco Nassisi
- Doheny Eye Institute, Los Angeles, California; Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | | | - Srinivas R Sadda
- Doheny Eye Institute, Los Angeles, California; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Quan V Hoang
- Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore, Republic of Singapore; Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University College of Physicians and Surgeons, New York, New York
| |
Collapse
|
26
|
Murakami T. OCT Angiography Image Stack Casts Light on Multifaceted Pathophysiologic Features in Diabetic Microaneurysms. Ophthalmol Retina 2020; 4:187-188. [PMID: 32033712 DOI: 10.1016/j.oret.2019.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 10/25/2019] [Accepted: 10/29/2019] [Indexed: 06/10/2023]
Affiliation(s)
- Tomoaki Murakami
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan.
| |
Collapse
|