1
|
Gou D, Zhu Q, Chan HK, Kourmatzis A, Cheng S, Yang R. Effects of the deformation and size of the upper airway on the deposition of aerosols. Int J Pharm 2024; 657:124165. [PMID: 38663643 DOI: 10.1016/j.ijpharm.2024.124165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 04/16/2024] [Accepted: 04/22/2024] [Indexed: 05/02/2024]
Abstract
Aerosol drug delivery in the human airway is significantly affected by the morphology and size of the airway. This work developed a CFD-DEM model to simulate and analyze air flow and powder dynamics in combined inhaler-airway systems with different degrees of airway deformation (non-deformed, 50%, and 75% deformed) and sizes (adult, 0.80, and 0.62 scaled). The airways were generated based on a regular airway constructed from the MRI images through finite element method (for deformed airways) or scaling-down (for smaller airways). The airways were connected to Turbuhaler® through a connector. The results showed that under the same flow rate, the variation in the airway geometry and size had a minimum impact on the flow field and powder deposition in the device and the connector. However, deformation caused more particle deposition in the deformed region. Notably, the airway with 50% deformation had the most particles passing through the airway with the largest particle sizes due to its lower air velocity in the deformed area. Reducing airway size resulted in more powder deposition on the airway, particularly at the pharynx and mouth regions. This was because, with the same flow rate, the flow velocity in the smaller airway was higher, causing more particle-wall collisions in the mouth and pharynx regions. More importantly, the deposition efficiency in the 0.62-scaled airway was significantly higher than the other two airways, highlighting the importance of the different administration of aerosol drugs for young children.
Collapse
Affiliation(s)
- Dazhao Gou
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia
| | - Qixuan Zhu
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Sydney Pharmacy School, The University of Sydney, NSW 2006, Australia
| | - Agisilaos Kourmatzis
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006, Australia
| | - Shaokoon Cheng
- School of Engineering, Macquarie University, NSW 2109, Australia
| | - Runyu Yang
- School of Materials Science and Engineering, UNSW Sydney, NSW 2052, Australia.
| |
Collapse
|
2
|
Zhu Q, Kakhi M, Jayasundara C, Walenga R, Behara SRB, Chan HK, Yang R. CFD-DEM investigation of the effects of aperture size for a capsule-based dry powder inhaler. Int J Pharm 2023; 647:123556. [PMID: 37890648 DOI: 10.1016/j.ijpharm.2023.123556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/02/2023] [Accepted: 10/24/2023] [Indexed: 10/29/2023]
Abstract
Capsule based dry powder inhalers (DPIs) often require piercing of the capsule before inhalation, and the characteristics of the apertures (punctured holes) affect air flow and the release of powders from the capsule. This work develops a numerical model based on the two-way coupling of computational fluid dynamics and discrete element method (CFD-DEM) to investigate the effect of aperture size on powder dispersion in the Aerolizer® device loaded with only carrier particles (lactose). Powders (carrier particles) in the size range 60-140 μm (d50: 90 μm and span: 0.66) were initialized in a capsule which had a circular aperture at each end. Boundary conditions corresponding to an air flow rate of 45 L/min were specified at each inlet to the mixing chamber (i.e., a total flow rate 90 L/min), and a capsule spin speed of ∼ 4050 rpm. The velocity magnitudes inside the capsule were considerably lower than those in the mixing chamber in the vicinity of the rotating capsule, with the exception of the capsules featuring 2.5 mm and 4 mm apertures. Larger apertures reduced the capsule emptying time and increased the particle evacuation velocity; the fluid drag force on the particles issuing from the capsule peaked for an aperture of 1.3 mm. Inside the capsule, particle-particle (PP) collisions were more frequent than particle-wall (PW) collisions due to high concentration of powder, but PP collisions had smaller (median) impact energy than PW collisions. Larger apertures resulted in fewer collisions in the capsule with higher PW and virtually unchanged PP collision energies. Outside the capsule (i.e., in the inhaler mixing chamber), PW collisions occurred more frequently than PP collisions with median collision energies typically two orders of magnitude higher than inside the capsule. Larger apertures resulted in more collisions with slightly reduced collision energy, but this effect plateaued for aperture sizes larger than 1.3 mm. Powder dispersion, expressed as the fine particle fraction (FPF) of the powder, was predicted using an empirical equation based on carrier PW collisions. Therefore, consistent with the model prediction of the effect of aperture sizes on the chamber collision frequency, FPF increased with aperture size but plateaued beyond 1.3 mm.
Collapse
Affiliation(s)
- Qixuan Zhu
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Maziar Kakhi
- Division of Product Quality Research, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Chandana Jayasundara
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Ross Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Srinivas Ravindra Babu Behara
- Division of Immediate and Modified Release Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney, NSW 2006, Australia
| | - Runyu Yang
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
3
|
Newman B, Babiskin A, Bielski E, Boc S, Dhapare S, Fang L, Feibus K, Kaviratna A, Li BV, Luke MC, Ma T, Spagnola M, Walenga RL, Wang Z, Zhao L, El-Gendy N, Bertha CM, Abd El-Shafy M, Gaglani DK. Scientific and regulatory activities initiated by the U.S. Food and drug administration to foster approvals of generic dry powder inhalers: Bioequivalence perspective. Adv Drug Deliv Rev 2022; 190:114526. [PMID: 36067967 DOI: 10.1016/j.addr.2022.114526] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/26/2022] [Accepted: 08/30/2022] [Indexed: 01/24/2023]
Abstract
Regulatory science for generic dry powder inhalers (DPIs) in the United States (U.S.) has evolved over the last decade. In 2013, the U.S. Food and Drug Administration (FDA) published the draft product-specific guidance (PSG) for fluticasone propionate and salmeterol xinafoate inhalation powder. This was the first PSG for a DPI available in the U.S., which provided details on a weight-of-evidence approach for establishing bioequivalence (BE). A variety of research activities including in vivo and in vitro studies were used to support these recommendations, which have led to the first approval of a generic DPI in the U.S. for fluticasone propionate and salmeterol xinafoate inhalation powder in January of 2019. This review describes the scientific and regulatory activities that have been initiated by FDA to support the current BE recommendations for DPIs that led to the first generic DPI approvals, as well as research with novel in vitro and in silico methods that may potentially facilitate generic DPI development and approval.
Collapse
Affiliation(s)
- Bryan Newman
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Andrew Babiskin
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Elizabeth Bielski
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Susan Boc
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Sneha Dhapare
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Lanyan Fang
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Katharine Feibus
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Anubhav Kaviratna
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Bing V Li
- Office of Bioequivalence, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Markham C Luke
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Tian Ma
- Division of Bioequivalence I, Office of Bioequivalence, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Michael Spagnola
- Division of Clinical Safety and Surveillance, Office of Safety and Clinical Evaluation, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Ross L Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA.
| | - Zhong Wang
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Liang Zhao
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Nashwa El-Gendy
- Division of Immediate and Modified Release Drug Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Craig M Bertha
- Division of New Drug Products II, Office of New Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Mohammed Abd El-Shafy
- Division of Immediate and Modified Release Drug Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Dhaval K Gaglani
- Division of Immediate and Modified Release Drug Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
4
|
Modelling Deaggregation Due to Normal Carrier–Wall Collision in Dry Powder Inhalers. Processes (Basel) 2022. [DOI: 10.3390/pr10081661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Powder deaggregation in Dry Powder Inhalers (DPI) with carrier-based formulations is a key process for the effectiveness of drug administration. Carrier-wall collisions are one of the recognised mechanisms responsible for active pharmaceutical ingredient (API) aerosolisation, and DPI geometries are designed to maximise their efficacy. The detachment of fine and cohesive API particles is investigated at a fundamental level by simulating with DEM the normal collision of a carrier sphere with an API particle attached. The impact velocity at which detachment occurs (escape velocity) is determined as a function of key parameters, such as cohesiveness, coefficient of restitution, static and rolling friction. An analytical model for the escape velocity is then derived, examining the role of the initial position of the particle, cohesion model and particle size. Finally, the results are framed in the context of DPI inhalers, comparing the results obtained with impact velocities typically recorded in commercial devices.
Collapse
|
5
|
Deagglomeration of selected high-load API-carrier particles in swirl-based dry powder inhalers. POWDER TECHNOL 2022. [DOI: 10.1016/j.powtec.2022.117800] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
6
|
Alfano FO, Benassi A, Gaspari R, Di Renzo A, Di Maio FP. Full-Scale DEM Simulation of Coupled Fluid and Dry-Coated Particle Flow in Swirl-Based Dry Powder Inhalers. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c02864] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
| | - Andrea Benassi
- DP Manufacturing & Innovation, Chiesi Farmaceutici SpA, 43122 Parma, Italy
- International School for Advanced Studies (SISSA), 34136 Trieste, Italy
| | - Roberto Gaspari
- DP Manufacturing & Innovation, Chiesi Farmaceutici SpA, 43122 Parma, Italy
| | | | | |
Collapse
|
7
|
Yaqoubi S, Chan HK, Nokhodchi A, Dastmalchi S, Alizadeh AA, Barzegar-Jalali M, Adibkia K, Hamishehkar H. A quantitative approach to predicting lung deposition profiles of pharmaceutical powder aerosols. Int J Pharm 2021; 602:120568. [PMID: 33812969 DOI: 10.1016/j.ijpharm.2021.120568] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/19/2021] [Accepted: 03/30/2021] [Indexed: 12/11/2022]
Abstract
Dry powder inhalers (DPI) are widely used systems for pulmonary delivery of therapeutics. The inhalation performance of DPIs is influenced by formulation features, inhaler device and inhalation pattern. The current review presents the affecting factors with great focus on powder characteristics which include particle size, shape, surface, density, hygroscopicity and crystallinity. The properties of a formulation are greatly influenced by a number of physicochemical factors of drug and added excipients. Since available particle engineering techniques result in particles with a set of modifications, it is difficult to distinguish the effect of an individual feature on powder deposition behavior. This necessitates developing a predictive model capable of describing all influential factors on dry powder inhaler delivery. Therefore, in the current study, a model was constructed to correlate the inhaler device properties, inhalation flow rate, particle characteristics and drug/excipient physicochemical properties with the resultant fine particle fraction. The r2 value of established correlation was 0.74 indicating 86% variability in FPF values is explained by the model with the mean absolute errors of 0.22 for the predicted values. The authors believe that this model is capable of predicting the lung deposition pattern of a formulation with an acceptable precision when the type of inhaler device, inhalation flow rate, physicochemical behavior of active and inactive ingredients and the particle characteristics of DPI formulations are considered.
Collapse
Affiliation(s)
- Shadi Yaqoubi
- Faculty of Pharmacy and Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| | - Ali Nokhodchi
- Pharmaceutics Research Laboratory, School of Life Sciences, University of Sussex, Brighton, UK
| | - Siavoush Dastmalchi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ali Akbar Alizadeh
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Barzegar-Jalali
- Pharmaceutical Analysis Research Center, and Department of Pharmaceutics, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Khosro Adibkia
- Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hamed Hamishehkar
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
8
|
Zheng Z, Leung SSY, Gupta R. Flow and Particle Modelling of Dry Powder Inhalers: Methodologies, Recent Development and Emerging Applications. Pharmaceutics 2021; 13:189. [PMID: 33535512 PMCID: PMC7912775 DOI: 10.3390/pharmaceutics13020189] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/22/2021] [Accepted: 01/27/2021] [Indexed: 11/16/2022] Open
Abstract
Dry powder inhaler (DPI) is a device used to deliver a drug in dry powder form to the lungs. A wide range of DPI products is currently available, with the choice of DPI device largely depending on the dose, dosing frequency and powder properties of formulations. Computational fluid dynamics (CFD), together with various particle motion modelling tools, such as discrete particle methods (DPM) and discrete element methods (DEM), have been increasingly used to optimise DPI design by revealing the details of flow patterns, particle trajectories, de-agglomerations and depositions within the device and the delivery paths. This review article focuses on the development of the modelling methodologies of flow and particle behaviours in DPI devices and their applications to device design in several emerging fields. Various modelling methods, including the most recent multi-scale approaches, are covered and the latest simulation studies of different devices are summarised and critically assessed. The potential and effectiveness of the modelling tools in optimising designs of emerging DPI devices are specifically discussed, such as those with the features of high-dose, pediatric patient compatibility and independency of patients' inhalation manoeuvres. Lastly, we summarise the challenges that remain to be addressed in DPI-related fluid and particle modelling and provide our thoughts on future research direction in this field.
Collapse
Affiliation(s)
- Zhanying Zheng
- Center for Turbulence Control, Harbin Institute of Technology, Shenzhen 518055, China
| | - Sharon Shui Yee Leung
- School of Pharmacy, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong;
| | - Raghvendra Gupta
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India;
| |
Collapse
|
9
|
Hemamanjushree S, Tippavajhala VK. Simulation of Unit Operations in Formulation Development of Tablets Using Computational Fluid Dynamics. AAPS PharmSciTech 2020; 21:103. [PMID: 32166477 DOI: 10.1208/s12249-020-1635-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Accepted: 02/05/2020] [Indexed: 11/30/2022] Open
Abstract
Tablets are the most customarily used solid oral unit dosage form for its better patient compliance. Preparation of these tablets include granulation, granule drying, die filling, and tablet coating as few unit operations and evaluation tests like dissolution test and disintegration test. These are the most crucial segments influencing the quality of the tablet. Critical analysis of the impact of factors like flow pattern, temperature, velocity, and other properties of fluid affecting the unit operations is obligatory to enhance their efficiency. Computational fluid dynamics (CFD), a combined mathematical and numerical approach, is used to analyze the process parameters of fluid affecting the abovementioned processes during tablet formulation. The equations governing the laws of conservation of energy, mass, and momentum are solved numerically utilizing CFD software for better understanding of the role of fluids within the tablet processing steps. This review not only focuses on discrete explanations on how CFD is utilized in formulation and evaluation of tablet but it is also a compilation of multiple research works performed on each unit operation by applying CFD.
Collapse
|
10
|
A particle technology approach toward designing dry-powder inhaler formulations for personalized medicine in respiratory diseases. ADV POWDER TECHNOL 2020. [DOI: 10.1016/j.apt.2019.10.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Olaleye AK, Shardt O, Walker GM, Van den Akker HE. Pneumatic conveying of cohesive dairy powder: Experiments and CFD-DEM simulations. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2019.09.046] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
12
|
Walenga RL, Babiskin AH, Zhao L. In Silico Methods for Development of Generic Drug-Device Combination Orally Inhaled Drug Products. CPT-PHARMACOMETRICS & SYSTEMS PHARMACOLOGY 2019; 8:359-370. [PMID: 31044532 PMCID: PMC6618094 DOI: 10.1002/psp4.12413] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 04/07/2019] [Indexed: 12/03/2022]
Abstract
The development of generic, single‐entity, drug–device combination products for orally inhaled drug products is challenging in part because of the complex nature of device design characteristics and the difficulties associated with establishing bioequivalence for a locally acting drug product delivered to the site of action in the lung. This review examines in silico models that may be used to support the development of generic orally inhaled drug products and how model credibility may be assessed.
Collapse
Affiliation(s)
- Ross L Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Andrew H Babiskin
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Liang Zhao
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
13
|
Towards quantitative prediction of the performance of dry powder inhalers by multi-scale simulations and experiments. Int J Pharm 2018; 547:31-43. [DOI: 10.1016/j.ijpharm.2018.05.047] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 05/17/2018] [Accepted: 05/19/2018] [Indexed: 02/02/2023]
|
14
|
Scherließ R, Etschmann C. DPI formulations for high dose applications - Challenges and opportunities. Int J Pharm 2018; 548:49-53. [PMID: 29940300 DOI: 10.1016/j.ijpharm.2018.06.038] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 06/08/2018] [Accepted: 06/17/2018] [Indexed: 02/07/2023]
Abstract
This opinion piece gives reasons for high dose DPI applications, points out challenges and shows opportunities and possible solutions for high dose DPI. This piece of work shall set the stage for more in-depth reviews of state of the art and research papers addressing the challenges of high dose DPI which shall be included in the special issue of IJP.
Collapse
Affiliation(s)
- Regina Scherließ
- Department of Pharmaceutics and Biopharmaceutics, Kiel University, Grasweg 9a, 24118 Kiel, Germany.
| | - Christian Etschmann
- Department of Pharmaceutics and Biopharmaceutics, Kiel University, Grasweg 9a, 24118 Kiel, Germany
| |
Collapse
|
15
|
CFD-based study of the abrasive flow characteristics within constrained flow passage in polishing of complex titanium alloy surfaces. POWDER TECHNOL 2018. [DOI: 10.1016/j.powtec.2018.04.046] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|