1
|
Draeger E, Roberts K, Decker RD, Bahar N, Wilson LD, Contessa J, Husain Z, Williams BB, Flood AB, Swartz HM, Carlson DJ. In Vivo Verification of Electron Paramagnetic Resonance Biodosimetry Using Patients Undergoing Radiation Therapy Treatment. Int J Radiat Oncol Biol Phys 2024; 119:292-301. [PMID: 38072322 DOI: 10.1016/j.ijrobp.2023.11.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/28/2023] [Accepted: 11/19/2023] [Indexed: 01/06/2024]
Abstract
PURPOSE Electron paramagnetic resonance (EPR) biodosimetry, used to triage large numbers of individuals incidentally exposed to unknown doses of ionizing radiation, is based on detecting a stable physical response in the body that is subject to quantifiable variation after exposure. In vivo measurement is essential to fully characterize the radiation response relevant to a living tooth measured in situ. The purpose of this study was to verify EPR spectroscopy in vivo by estimating the radiation dose received in participants' teeth. METHODS AND MATERIALS A continuous wave L-band spectrometer was used for EPR measurements. Participants included healthy volunteers and patients undergoing head and neck and total body irradiation treatments. Healthy volunteers completed 1 measurement each, and patients underwent measurement before starting treatment and between subsequent fractions. Optically stimulated luminescent dosimeters and diodes were used to determine the dose delivered to the teeth to validate EPR measurements. RESULTS Seventy measurements were acquired from 4 total body irradiation and 6 head and neck patients over 15 months. Patient data showed a linear increase of EPR signal with delivered dose across the dose range tested. A linear least-squares weighted fit of the data gave a statistically significant correlation between EPR signal and absorbed dose (P < .0001). The standard error of inverse prediction (SEIP), used to assess the usefulness of fits, was 1.92 Gy for the dose range most relevant for immediate triage (≤7 Gy). Correcting for natural background radiation based on patient age reduced the SEIP to 1.51 Gy. CONCLUSIONS This study demonstrated the feasibility of using spectroscopic measurements from radiation therapy patients to validate in vivo EPR biodosimetry. The data illustrated a statistically significant correlation between the magnitude of EPR signals and absorbed dose. The SEIP of 1.51 Gy, obtained under clinical conditions, indicates the potential value of this technique in response to large radiation events.
Collapse
Affiliation(s)
- Emily Draeger
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| | - Kenneth Roberts
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Roy D Decker
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Nina Bahar
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Lynn D Wilson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Joseph Contessa
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Zain Husain
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Benjamin B Williams
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Ann Barry Flood
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Harold M Swartz
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - David J Carlson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| |
Collapse
|
2
|
Swartz HM, Flood AB. EPR biodosimetry: challenges and opportunities. RADIATION PROTECTION DOSIMETRY 2023; 199:1441-1449. [PMID: 37721062 DOI: 10.1093/rpd/ncad009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 10/27/2022] [Accepted: 01/10/2023] [Indexed: 09/19/2023]
Abstract
This paper briefly examines electron paramagnetic resonance (EPR) techniques to measure dose from exposure to external radiation, assessing their current status, potential future uses and the challenges impacting their progress. We conclude the uses and potential value of different EPR techniques depend on the number of victims and whether they characterize short- or long-term risks from exposure. For large populations, EPR biodosimetry based on in vivo measurements or using co-located inanimate objects offer the greatest promise for assessing acute, life-threatening risk and the magnitude and extent of such risk. To assess long-term risk, ex vivo EPR methods using concentrated enamel from exfoliated teeth are most impactful. For small groups, ex vivo EPR biodosimetry based on available samples of teeth, nails and/or bones are most useful. The most important challenges are common to all approaches: improve the technique's technical capabilities and advance recognition by planning groups of the relative strengths EPR techniques offer for each population size. The most useful applications are likely to be for triage and medical guidance in large events and for radiation epidemiology to evaluate long-term risks.
Collapse
Affiliation(s)
- Harold M Swartz
- Radiology Department, Geisel School of Medicine, Dartmouth College, Hanover, NH, USA
- Clin-EPR, LLC, Lyme, NH, USA
| | - Ann Barry Flood
- Radiology Department, Geisel School of Medicine, Dartmouth College, Hanover, NH, USA
- Clin-EPR, LLC, Lyme, NH, USA
| |
Collapse
|
3
|
Flood AB, Sidabras JW, Swarts SG, Buehler PW, Schreiber W, Grinberg O, Swartz HM. Benefits and challenges of in vivo EPR nail biodosimetry in a second tier of medical triage in response to a large radiation event. RADIATION PROTECTION DOSIMETRY 2023; 199:1539-1550. [PMID: 37721065 PMCID: PMC10505939 DOI: 10.1093/rpd/ncad022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 01/09/2023] [Accepted: 01/10/2023] [Indexed: 09/19/2023]
Abstract
Following large-scale radiation events, an overwhelming number of people will potentially need mitigators or treatment for radiation-induced injuries. This necessitates having methods to triage people based on their dose and its likely distribution, so life-saving treatment is directed only to people who can benefit from such care. Using estimates of victims following an improvised nuclear device striking a major city, we illustrate a two-tier approach to triage. At the second tier, after first removing most who would not benefit from care, biodosimetry should provide accurate dose estimates and determine whether the dose was heterogeneous. We illustrate the value of using in vivo electron paramagnetic resonance nail biodosimetry to rapidly assess dose and determine its heterogeneity using independent measurements of nails from the hands and feet. Having previously established its feasibility, we review the benefits and challenges of potential improvements of this method that would make it particularly suitable for tier 2 triage. Improvements, guided by a user-centered approach to design and development, include expanding its capability to make simultaneous, independent measurements and improving its precision and universality.
Collapse
Affiliation(s)
- Ann Barry Flood
- Radiology Department, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH, USA
- Clin-EPR, LLC, Lyme, NH, USA
| | - Jason W Sidabras
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Steven G Swarts
- Department of Radiation Oncology, University of Florida, Gainesville, FL, USA
| | - Paul W Buehler
- Department of Pathology, University of Maryland, Baltimore, MD, USA
| | | | | | - Harold M Swartz
- Radiology Department, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH, USA
- Clin-EPR, LLC, Lyme, NH, USA
| |
Collapse
|
4
|
Romanyukha A, Tolmachev SY. Electron paramagnetic resonance dose measurements in teeth of tissue donors to the United States Transuranium and Uranium Registries. RADIATION PROTECTION DOSIMETRY 2023; 199:1578-1585. [PMID: 37721075 DOI: 10.1093/rpd/ncac261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 09/19/2023]
Abstract
The United States Transuranium and Uranium Registries (USTUR) is a research program that studies actinide biokinetics in occupationally exposed individuals with known intakes of these elements. Electron paramagnetic resonance (EPR) in tooth enamel was applied to reconstruct external doses of nine USTUR registrants. Only in two cases there is a reasonable agreement between the EPR-measured dose and the worksite external dose record. For two registrants, high EPR doses can be explained by possible cancer radiotherapy. For the remaining five cases, EPR doses significantly exceed official occupational doses with no plausible explanation for the observed discrepancy. More EPR dose measurements need to be done to explain this anomaly.
Collapse
Affiliation(s)
- A Romanyukha
- Naval Dosimetry Center, 4975 North Palmer Road, Bethesda, MD 20889, USA
| | - S Y Tolmachev
- College of Pharmacy and Pharmaceutical Sciences, Washington State University, 1845 Terminal Drive, Suite 201, Richland, WA 99354, USA
| |
Collapse
|
5
|
Vinnikov V, Belyakov O. Clinical Applications of Biological Dosimetry in Patients Exposed to Low Dose Radiation Due to Radiological, Imaging or Nuclear Medicine Procedures. Semin Nucl Med 2021; 52:114-139. [PMID: 34879905 DOI: 10.1053/j.semnuclmed.2021.11.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Radiation dosimetric biomarkers have found applications beyond radiation protection area and now are actively introduced into clinical practice. Cytogenetic assays appeared to be a valuable tool for individualized quantifying radiation effects in patients, with high capability for assessing genotoxicity of various medical exposure modalities and providing meaningful radiation dose estimates for prognoses of radiation-related cancer risk. This review summarized current data on the use of biological dosimetry methods in patients undergoing various medical irradiations to low doses. The highlighted topics include basic aspects of biological dosimetry and its limitations in the range of low radiation doses, and main patterns of in vivo induction of radiation biomarkers in clinical exposure scenarios, occurring in X-ray diagnostics, computed tomography, interventional radiology, low dose radiotherapy, and nuclear medicine (internally administered 131I and other radiopharmaceuticals). Additionally, several specific issues, examined by biodosimetry techniques, are analysed, such as contrast media effect, radiation response in pediatric patients, impact of magnetic resonance imaging, evaluation of radioprotectors, detection of patients' abnormal intrinsic radiosensitivity and dose estimation in persons involved in medical radiation incidents. A prognosis of possible directions for further improvements in this area includes the automation of cytogenetic analysis, introduction of molecular biodosimeters and development of multiparametric biodosimetry platforms. A potential approach to the advanced biodosimetry of internal exposure and/or low dose external irradiation is suggested; this can be a multiparametric platform based on the combination of the γ-H2AX foci, dicentric, and translocation assays, each applied in the optimum postexposure time range, with the amalgamation of the dose estimates. The study revealed the necessity of further research, which might clarify medical radiation safety concerns for patients via using stringent biodosimetry methodology.
Collapse
Affiliation(s)
- Volodymyr Vinnikov
- International Atomic Energy Agency (IAEA), Vienna, Austria; Grigoriev Institute for Medical Radiology and Oncology (GIMRO), Kharkiv, Ukraine.
| | - Oleg Belyakov
- International Atomic Energy Agency (IAEA), Vienna, Austria
| |
Collapse
|
6
|
X-band TE101 rectangular aperture cavity for in vivo EPR tooth dosimetry after radiation emergency. Appl Radiat Isot 2021; 178:109958. [PMID: 34598040 DOI: 10.1016/j.apradiso.2021.109958] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/25/2021] [Accepted: 09/16/2021] [Indexed: 11/22/2022]
Abstract
The TE101 mode rectangle EPR cavity was newly developed to achieve X-band in vivo EPR tooth dosimetry for the rescue of nuclear emergency. An aperture for sample detection was opened on the cavity's surface. Its characteristics were evaluated by measuring DPPH and intact human incisor samples. Remarkable radiation induced signal from EPR spectrum of 1Gy-8Gy irradiated teeth was observed. In vivo measurements of rat was performed to verify its application for in vivo tooth dosimetry.
Collapse
|
7
|
Vinnikov VA, Belyakov O. Radiation Exposure Biomarkers in the Practice of Medical Radiology: Cooperative Research and the Role of the International Atomic Energy Agency (IAEA) Biodosimetry/Radiobiology Laboratory. HEALTH PHYSICS 2020; 119:83-94. [PMID: 32483044 DOI: 10.1097/hp.0000000000001266] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The strategy toward personalized medicine in radiation oncology, nuclear medicine, and diagnostic and interventional radiology demands a specific set of assays for individualized estimation of radiation load for safety concerns and prognosis of normal tissue reactions caused by ionizing radiation. Apparently, it seems reasonable to use validated radiation dosimetric biomarkers for these purposes. However, a number of gaps in knowledge and methodological limitations still have to be resolved until dosimetric biomarkers will start to play a valuable role in clinical practice beyond radiation protection and radiation medicine. An extensive international multicenter research is necessary to improve the methodology of clinical applications of biodosimetry. That became a rationale for launching the IAEA Coordinated Research Project E35010 MEDBIODOSE: "Applications of Biological Dosimetry Methods in Radiation Oncology, Nuclear Medicine, and Diagnostic and Interventional Radiology." At the 2 Coordination Meeting on MEDBIODOSE (18-22 February 2019, Recife, Brazil), participants reported progress in the usage of biological dosimetry for genotoxicity assessment and/or individualization of radiotherapy treatment plans. Another avenue of research was the prognosis of normal tissue toxicity and cancer risk prediction using biomarkers' yield measured in vivo or after ex vivo irradiation of patients' cells. Other important areas are mechanisms of cytogenetic radiation response, validation of new radiation biomarkers, development of innovative techniques, automated and high-throughput assays for biodosimetry, and the overall improvement of biodosimetry service. An important aspect of clinical application of biodosimetry is standardization of techniques and unification of approaches to data interpretation. The new IAEA Biodosimetry/Radiobiology Laboratory, which is being established, will provide support for this activity. The declared lab's mission includes, among other tasks, a harmonization of the biodosimetry applications with relevant international standards, guidelines on good laboratory practice, and the IAEA EPR-Biodosimetry manual.
Collapse
Affiliation(s)
- Volodymyr A Vinnikov
- Grigoriev Institute for Medical Radiology, Ukranian National Academy of Medical Sciences, Pushkinskaya 82, Kharkiv 61024 Ukraine
| | - Oleg Belyakov
- International Atomic Energy Agency, Vienna International Centre, P.O. Box 100, Vienna A-1400, Austria
| |
Collapse
|
8
|
Abstract
Radiation accidents are rare, but can produce large numbers of casualties with predictable patterns of injury. Casualties may suffer from a wide range of radiation exposures. Triage based on presence or absence of conventional injuries and an accurate assessment of radiation dose based on event history, symptoms, and laboratory testing, is critical. Treatment of acute radiation syndrome is supportive: including fluids, antibiotics, blood products, colony-stimulating factors, and stem cell or bone marrow transplantation. Care of radiation-injured patients with conventional trauma or burns needs to be modified to account for adverse effects of radiation on wound healing and susceptibility to infections.
Collapse
Affiliation(s)
- John S Parrish
- Department of Pulmonary and Critical Care Medicine, Naval Medical Center San Diego, 34800 Bob Wilson Drive, Suite 301, San Diego, CA 92134, USA.
| | - Gilbert Seda
- Department of Pulmonary and Critical Care Medicine, Naval Medical Center San Diego, 34800 Bob Wilson Drive, Suite 301, San Diego, CA 92134, USA
| |
Collapse
|
9
|
Construction of dose response curves up to 6 Gy for Micronucleus and Dicentric Chromosome Aberration Assay with 6 MV X-ray Beam. RADIAT MEAS 2018. [DOI: 10.1016/j.radmeas.2018.05.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
10
|
Swarts SG, Sidabras JW, Grinberg O, Tipikin DS, Kmiec M, Petryakov S, Schreiber W, Wood VA, Williams BB, Flood AB, Swartz HM. Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry. HEALTH PHYSICS 2018; 115:140-150. [PMID: 29787440 PMCID: PMC5967651 DOI: 10.1097/hp.0000000000000874] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Instrumentation and application methodologies for rapidly and accurately estimating individual ionizing radiation dose are needed for on-site triage in a radiological/nuclear event. One such methodology is an in vivo X-band, electron paramagnetic resonance, physically based dosimetry method to directly measure the radiation-induced signal in fingernails. The primary components under development are key instrument features, such as resonators with unique geometries that allow for large sampling volumes but limit radiation-induced signal measurements to the nail plate, and methodological approaches for addressing interfering signals in the nail and for calibrating dose from radiation-induced signal measurements. One resonator development highlighted here is a surface resonator array designed to reduce signal detection losses due to the soft tissues underlying the nail plate. Several surface resonator array geometries, along with ergonomic features to stabilize fingernail placement, have been tested in tissue-equivalent nail models and in vivo nail measurements of healthy volunteers using simulated radiation-induced signals in their fingernails. These studies demonstrated radiation-induced signal detection sensitivities and quantitation limits approaching the clinically relevant range of ≤ 10 Gy. Studies of the capabilities of the current instrument suggest that a reduction in the variability in radiation-induced signal measurements can be obtained with refinements to the surface resonator array and ergonomic features of the human interface to the instrument. Additional studies are required before the quantitative limits of the assay can be determined for triage decisions in a field application of dosimetry. These include expanded in vivo nail studies and associated ex vivo nail studies to provide informed approaches to accommodate for a potential interfering native signal in the nails when calculating the radiation-induced signal from the nail plate spectral measurements and to provide a method for calibrating dose estimates from the radiation-induced signal measurements based on quantifying experiments in patients undergoing total-body irradiation or total-skin electron therapy.
Collapse
Affiliation(s)
- Steven G. Swarts
- Department of Radiation Oncology, University of Florida, Gainesville, Florida 32618
| | - Jason W. Sidabras
- Max Planck for Chemical Energy Conversion, Biophysical Chemistry, Mülheim, Germany
| | - Oleg Grinberg
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | | | - Maciej Kmiec
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Sergey Petryakov
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Wilson Schreiber
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Victoria A. Wood
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | | | - Ann Barry Flood
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Harold M. Swartz
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| |
Collapse
|
11
|
Desmet CM, Levêque P, Gallez B. Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:96-102. [PMID: 27473693 PMCID: PMC5225974 DOI: 10.1093/rpd/ncw212] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In vivo electron paramagnetic resonance biodosimetry on tooth enamel is likely to be an important technology for triage of overexposed individuals after a major radiological incident. The accuracy and robustness of the technique relies on various properties of the enamel such as the geometry of the tooth, the presence of restorations, whitening treatments or exposition to sunlight. Those factors are reviewed, and their influence on dosimetry specifically for triage purposes is discussed.
Collapse
Affiliation(s)
- Céline M Desmet
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Philippe Levêque
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| |
Collapse
|
12
|
Abstract
EPR (electron paramagnetic resonance) based biological oximetry is a powerful tool that accurately and repeatedly measures tissue oxygen levels. In vivo determination of oxygen in tissues is crucial for the diagnosis and treatment of a number of diseases. Here, we report the first successful fabrication and remarkable properties of nanofiber sensors for EPR-oximetry applications. Lithium octa-n-butoxynaphthalocyanine (LiNc- BuO), an excellent paramagnetic oxygen sensor, was successfully encapsulated in 300-500 nm diameter fibers consisting of a core of polydimethylsiloxane (PDMS) and a shell of polycaprolactone (PCL) by electrospinning. This core-shell nanosensor (LiNc-BuO-PDMS-PCL) shows a linear dependence of linewidth versus oxygen partial pressure (pO2). The nanofiber sensors have response and recovery times of 0.35 s and 0.55 s, respectively, these response and recovery times are ~12 times and ~218 times faster than those previously reported for PDMS-LiNc-BuO chip sensors. This greater responsiveness is likely due to the high porosity and excellent oxygen permeability of the nanofibers. Electrospinning of the structurally flexible PDMS enabled the fabrication of fibers having tailored spin densities. Core-shell encapsulation ensures the non-exposure of embedded LiNc-BuO and mitigates potential biocompatibility concerns. In vitro evaluation of the fiber performed under exposure to cultured cells showed that it is both stable and biocompatible. The unique combination of biocompatibility due to the PCL 'shell,' the excellent oxygen transparency of the PDMS core, and the excellent oxygen-sensing properties of LiNc-BuO makes LiNc-BuO-PDMS-PCL platform promising for long-term oximetry and repetitive oxygen measurements in both biological systems and clinical applications.
Collapse
|
13
|
Bailiff I, Sholom S, McKeever S. Retrospective and emergency dosimetry in response to radiological incidents and nuclear mass-casualty events: A review. RADIAT MEAS 2016. [DOI: 10.1016/j.radmeas.2016.09.004] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
14
|
Flood AB, Ali AN, Boyle HK, Du G, Satinsky VA, Swarts SG, Williams BB, Demidenko E, Schreiber W, Swartz HM. Evaluating the Special Needs of The Military for Radiation Biodosimetry for Tactical Warfare Against Deployed Troops: Comparing Military to Civilian Needs for Biodosimetry Methods. HEALTH PHYSICS 2016; 111:169-82. [PMID: 27356061 PMCID: PMC4930006 DOI: 10.1097/hp.0000000000000538] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The aim of this paper is to delineate characteristics of biodosimetry most suitable for assessing individuals who have potentially been exposed to significant radiation from a nuclear device explosion when the primary population targeted by the explosion and needing rapid assessment for triage is civilians vs. deployed military personnel. The authors first carry out a systematic analysis of the requirements for biodosimetry to meet the military's needs to assess deployed troops in a warfare situation, which include accomplishing the military mission. Then the military's special capabilities to respond and carry out biodosimetry for deployed troops in warfare are compared and contrasted systematically, in contrast to those available to respond and conduct biodosimetry for civilians who have been targeted by terrorists, for example. Then the effectiveness of different biodosimetry methods to address military vs. civilian needs and capabilities in these scenarios was compared and, using five representative types of biodosimetry with sufficient published data to be useful for the simulations, the number of individuals are estimated who could be assessed by military vs. civilian responders within the timeframe needed for triage decisions. Analyses based on these scenarios indicate that, in comparison to responses for a civilian population, a wartime military response for deployed troops has both more complex requirements for and greater capabilities to use different types of biodosimetry to evaluate radiation exposure in a very short timeframe after the exposure occurs. Greater complexity for the deployed military is based on factors such as a greater likelihood of partial or whole body exposure, conditions that include exposure to neutrons, and a greater likelihood of combined injury. These simulations showed, for both the military and civilian response, that a very fast rate of initiating the processing (24,000 d) is needed to have at least some methods capable of completing the assessment of 50,000 people within a 2- or 6-d timeframe following exposure. This in turn suggests a very high capacity (i.e., laboratories, devices, supplies and expertise) would be necessary to achieve these rates. These simulations also demonstrated the practical importance of the military's superior capacity to minimize time to transport samples to offsite facilities and use the results to carry out triage quickly. Assuming sufficient resources and the fastest daily rate to initiate processing victims, the military scenario revealed that two biodosimetry methods could achieve the necessary throughput to triage 50,000 victims in 2 d (i.e., the timeframe needed for injured victims), and all five achieved the targeted throughput within 6 d. In contrast, simulations based on the civilian scenario revealed that no method could process 50,000 people in 2 d and only two could succeed within 6 d.
Collapse
Affiliation(s)
- Ann Barry Flood
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Arif N. Ali
- Department of Radiation Oncology, Emory University School of Medicine, Atlanta, GA
| | - Holly K. Boyle
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Gaixin Du
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | | | - Steven G. Swarts
- Department of Radiation Oncology, College of Medicine, University of Florida, Gainesville, FL
| | - Benjamin B. Williams
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
- Radiation Oncology Division, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Eugene Demidenko
- Department of Biomedical Data Science, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Wilson Schreiber
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Harold M. Swartz
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
- Radiation Oncology Division, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| |
Collapse
|
15
|
Mishra DR, Soni A, Rawat NS, Bokam G. Study of thermoluminescence (TL) and optically stimulated luminescence (OSL) from α-keratin protein found in human hairs and nails: potential use in radiation dosimetry. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2016; 55:255-264. [PMID: 26846648 DOI: 10.1007/s00411-016-0634-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2014] [Accepted: 01/16/2016] [Indexed: 06/05/2023]
Abstract
The thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of human nails and hairs containing α-keratin proteins have been investigated. For the present studies, black hairs and finger nails were selectively collected from individuals with ages between 25 and 35 years. The collected hairs/nails were cut to a size of < 1 mm and cleaned with distilled water to remove dirt and other potential physical sources of contamination. All samples were optically beached with 470 nm of LED light at 60 mW/cm(2) intensity and irradiated by a (60)Co γ source. The hair and nail samples showed overlapping multiple TL glow peaks in the temperature range from 70 to 210 ° C. Continuous wave (CW)-OSL measurements of hair samples at a wavelength of 470 nm showed the presence of two distinct OSL components with photoionization cross section (PIC) values of about 1.65 × 10(-18) cm(2) and about 3.48 × 10(-19) cm(2), while measurements of nail samples showed PIC values of about 6.98 × 10(-18) cm(2) and about 8.7 × 10(-19) cm(2), respectively. This difference in PIC values for hair and nail samples from the same individual is attributed to different arrangement of α-keratin protein concentrations in the samples. The OSL sensitivity was found to vary ± 5 times among nail and hair samples from different individuals, with significant fading (60% in 11 h) at room temperature. The remaining signal (after fading) can be useful for dose estimation when a highly sensitive OSL reader is used. In the absorbed dose range of 100 mGy-100 Gy, both the TL and OSL signals of hair and nail samples showed linear dose dependence. The results obtained in the present study suggest that OSL using hair and nail samples may provide a supplementary method of dose estimation in radiological and nuclear emergencies.
Collapse
Affiliation(s)
- D R Mishra
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India.
| | - A Soni
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India
| | - N S Rawat
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India
| | - G Bokam
- Radiological Safety Division, Atomic Energy Regulatory Board, Mumbai, 400 094, India
| |
Collapse
|
16
|
Ulsh BA, Dolling J, Lavoie J, Mitchel REJ, Boreham DR. Chromosome Damage Caused by Accidental Chronic Whole-Body Gamma Radiation Exposure in Thailand. Dose Response 2015; 13:1559325815614302. [PMID: 26740811 PMCID: PMC4674019 DOI: 10.1177/1559325815614302] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In February 2000, a radiation incident involving a medical 60Co source occurred in a metal scrapyard in Thailand. Several individuals were suspected to have received chronic or fractionated exposures ranging from a few mGy to a several Gy. Using fluorescence in situ hybridization to paint chromosomes, we determined the frequencies of chromosome aberrations in peripheral blood lymphocytes of 13 people who entered the scrapyard, 3 people who involved in recovering the source, and 9 nearby residents. Aberration frequencies greater than controls were observed in 13 of the donors at 3 months postexposure. The predominant form of aberration observed was simple, complete, symmetrical translocations. An approximate 50% decrease in these aberrations and in total color junctions was observed in 7 donors resampled at 16 months postexposure. Although high, acute exposures are known to have detrimental effects, the biological consequences of chronic, low dose-rate radiation exposures are unclear. Thirteen of the donors had elevated aberration frequencies, and 6 also had symptoms of acute radiation syndrome. If there are any long-term health consequences of this incident, it will most likely occur among this group of individuals. The consequences for the remaining donors, who presumably received lower total doses delivered at lower dose rates, are less clear.
Collapse
Affiliation(s)
- B A Ulsh
- McMaster University Institute of Applied Radiation Sciences, Hamilton, Ontario, Canada; M. H. Chew & Associates, Cincinnati, OH, USA
| | - J Dolling
- McMaster University Institute of Applied Radiation Sciences, Hamilton, Ontario, Canada
| | - J Lavoie
- McMaster University Institute of Applied Radiation Sciences, Hamilton, Ontario, Canada
| | - R E J Mitchel
- Chalk River Laboratories, Atomic Energy of Canada, Ltd, Chalk River, Ontario, Canada
| | - D R Boreham
- McMaster University Institute of Applied Radiation Sciences, Hamilton, Ontario, Canada
| |
Collapse
|
17
|
Rychert KM, Zhu G, Kmiec MM, Nemani VK, Williams BB, Flood AB, Swartz HM, Gimi B. Imaging tooth enamel using zero echo time (ZTE) magnetic resonance imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2015; 9417:94171I. [PMID: 25914509 PMCID: PMC4405678 DOI: 10.1117/12.2083995] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
In an event where many thousands of people may have been exposed to levels of radiation that are sufficient to cause the acute radiation syndrome, we need technology that can estimate the absorbed dose on an individual basis for triage and meaningful medical decision making. Such dose estimates may be achieved using in vivo electron paramagnetic resonance (EPR) tooth biodosimetry, which measures the number of persistent free radicals that are generated in tooth enamel following irradiation. However, the accuracy of dose estimates may be impacted by individual variations in teeth, especially the amount and distribution of enamel in the inhomogeneous sensitive volume of the resonator used to detect the radicals. In order to study the relationship between interpersonal variations in enamel and EPR-based dose estimates, it is desirable to estimate these parameters nondestructively and without adding radiation to the teeth. Magnetic Resonance Imaging (MRI) is capable of acquiring structural and biochemical information without imparting additional radiation, which may be beneficial for many EPR dosimetry studies. However, the extremely short T2 relaxation time in tooth structures precludes tooth imaging using conventional MRI methods. Therefore, we used zero echo time (ZTE) MRI to image teeth ex vivo to assess enamel volumes and spatial distributions. Using these data in combination with the data on the distribution of the transverse radio frequency magnetic field from electromagnetic simulations, we then can identify possible sources of variations in radiation-induced signals detectable by EPR. Unlike conventional MRI, ZTE applies spatial encoding gradients during the RF excitation pulse, thereby facilitating signal acquisition almost immediately after excitation, minimizing signal loss from short T2 relaxation times. ZTE successfully provided volumetric measures of tooth enamel that may be related to variations that impact EPR dosimetry and facilitate the development of analytical procedures for individual dose estimates.
Collapse
Affiliation(s)
- Kevin M. Rychert
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Gang Zhu
- MRI Division, Bruker BioSpin Corporation, 15 Fortune Drive, Billerica, MA 01821
| | - Maciej M. Kmiec
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Venkata K. Nemani
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Benjamin B. Williams
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Ann Barry Flood
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Harold M. Swartz
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Barjor Gimi
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| |
Collapse
|
18
|
New developed cylindrical TM010 mode EPR cavity for X-band in vivo tooth dosimetry. PLoS One 2014; 9:e106587. [PMID: 25222483 PMCID: PMC4164439 DOI: 10.1371/journal.pone.0106587] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 07/30/2014] [Indexed: 11/20/2022] Open
Abstract
EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.
Collapse
|
19
|
Sugawara H, Hirata H, Petryakov S, Lesniewski P, Williams BB, Flood AB, Swartz HM. Design and Evaluation of a 1.1-GHz Surface Coil Resonator for Electron Paramagnetic Resonance-Based Tooth Dosimetry. IEEE Trans Biomed Eng 2014; 61:1894-901. [DOI: 10.1109/tbme.2014.2310217] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
20
|
Williams BB, Flood AB, Salikhov I, Kobayashi K, Dong R, Rychert K, Du G, Schreiber W, Swartz HM. In vivo EPR tooth dosimetry for triage after a radiation event involving large populations. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:335-46. [PMID: 24711003 PMCID: PMC11064839 DOI: 10.1007/s00411-014-0534-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 02/27/2014] [Indexed: 05/26/2023]
Abstract
The management of radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation will rely critically on the availability and use of suitable biodosimetry methods. In vivo electron paramagnetic resonance (EPR) tooth dosimetry has a number of valuable and unique characteristics and capabilities that may help enable effective triage. We have produced a prototype of a deployable EPR tooth dosimeter and tested it in several in vitro and in vivo studies to characterize the performance and utility at the state of the art. This report focuses on recent advances in the technology, which strengthen the evidence that in vivo EPR tooth dosimetry can provide practical, accurate, and rapid measurements in the context of its intended use to help triage victims in the event of an improvised nuclear device. These advances provide evidence that the signal is stable, accurate to within 0.5 Gy, and can be successfully carried out in vivo. The stability over time of the radiation-induced EPR signal from whole teeth was measured to confirm its long-term stability and better characterize signal behavior in the hours following irradiation. Dosimetry measurements were taken for five pairs of natural human upper central incisors mounted within a simple anatomic mouth model that demonstrates the ability to achieve 0.5 Gy standard error of inverse dose prediction. An assessment of the use of intact upper incisors for dose estimation and screening was performed with volunteer subjects who have not been exposed to significant levels of ionizing radiation and patients who have undergone total body irradiation as part of bone marrow transplant procedures. Based on these and previous evaluations of the performance and use of the in vivo tooth dosimetry system, it is concluded that this system could be a very valuable resource to aid in the management of a massive radiological event.
Collapse
Affiliation(s)
- Benjamin B Williams
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA,
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Swartz HM, Williams BB, Flood AB. Overview of the principles and practice of biodosimetry. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:221-32. [PMID: 24519326 PMCID: PMC5982531 DOI: 10.1007/s00411-014-0522-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Accepted: 02/02/2014] [Indexed: 05/05/2023]
Abstract
The principle of biodosimetry is to utilize changes induced in the individual by ionizing radiation to estimate the dose and, if possible, to predict or reflect the clinically relevant response, i.e., the biological consequences of the dose. Ideally, the changes should be specific for ionizing radiation, and the response should be unaffected by prior medical or physiological variations among subjects, including changes that might be caused by the stress and trauma from a radiation event. There are two basic types of biodosimetry with different and often complementary characteristics: those based on changes in biological parameters such as gene activation or chromosomal abnormalities and those based on physical changes in tissues (detected by techniques such as EPR). In this paper, we consider the applicability of the various techniques for different scenarios: small- and large-scale exposures to levels of radiation that could lead to the acute radiation syndrome and exposures with lower doses that do not need immediate care, but should be followed for evidence of long-term consequences. The development of biodosimetry has been especially stimulated by the needs after a large-scale event where it is essential to have a means to identify those individuals who would benefit from being brought into the medical care system. Analyses of the conventional methods officially recommended for responding to such events indicate that these methods are unlikely to achieve the results needed for timely triage of thousands of victims. Emerging biodosimetric methods can fill this critically important gap.
Collapse
Affiliation(s)
- Harold M Swartz
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA,
| | | | | |
Collapse
|
22
|
The Urine Proteome as a Radiation Biodosimeter. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2013; 990:87-100. [DOI: 10.1007/978-94-007-5896-4_5] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
23
|
Demidenko E, Williams BB, Flood AB, Swartz HM. Standard error of inverse prediction for dose-response relationship: approximate and exact statistical inference. Stat Med 2012; 32:2048-61. [PMID: 23124816 DOI: 10.1002/sim.5668] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Accepted: 10/01/2012] [Indexed: 11/12/2022]
Abstract
This paper develops a new metric, the standard error of inverse prediction (SEIP), for a dose-response relationship (calibration curve) when dose is estimated from response via inverse regression. SEIP can be viewed as a generalization of the coefficient of variation to regression problem when x is predicted using y-value. We employ nonstandard statistical methods to treat the inverse prediction, which has an infinite mean and variance due to the presence of a normally distributed variable in the denominator. We develop confidence intervals and hypothesis testing for SEIP on the basis of the normal approximation and using the exact statistical inference based on the noncentral t-distribution. We derive the power functions for both approaches and test them via statistical simulations. The theoretical SEIP, as the ratio of the regression standard error to the slope, is viewed as reciprocal of the signal-to-noise ratio, a popular measure of signal processing. The SEIP, as a figure of merit for inverse prediction, can be used for comparison of calibration curves with different dependent variables and slopes. We illustrate our theory with electron paramagnetic resonance tooth dosimetry for a rapid estimation of the radiation dose received in the event of nuclear terrorism.
Collapse
Affiliation(s)
- Eugene Demidenko
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA.
| | | | | | | |
Collapse
|
24
|
Swartz HM, Flood AB, Williams BB, Dong R, Swarts SG, He X, Grinberg O, Sidabras J, Demidenko E, Gui J, Gladstone DJ, Jarvis LA, Kmiec MM, Kobayashi K, Lesniewski PN, Marsh SDP, Matthews TP, Nicolalde RJ, Pennington PM, Raynolds T, Salikhov I, Wilcox DE, Zaki BI. Electron paramagnetic resonance dosimetry for a large-scale radiation incident. HEALTH PHYSICS 2012; 103:255-67. [PMID: 22850230 PMCID: PMC3649772 DOI: 10.1097/hp.0b013e3182588d92] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.
Collapse
|
25
|
Romanyukha A, King DL, Kennemur LK. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan. HEALTH PHYSICS 2012; 102:535-541. [PMID: 22469931 DOI: 10.1097/hp.0b013e31824c9594] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.
Collapse
|
26
|
Flood AB, Nicolalde RJ, Demidenko E, Williams BB, Shapiro A, Wiley AL, Swartz HM. A Framework for Comparative Evaluation of Dosimetric Methods to Triage a Large Population Following a Radiological Event. RADIAT MEAS 2011; 46:916-922. [PMID: 21949481 PMCID: PMC3178340 DOI: 10.1016/j.radmeas.2011.02.019] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND: To prepare for a possible major radiation disaster involving large numbers of potentially exposed people, it is important to be able to rapidly and accurately triage people for treatment or not, factoring in the likely conditions and available resources. To date, planners have had to create guidelines for triage based on methods for estimating dose that are clinically available and which use evidence extrapolated from unrelated conditions. Current guidelines consequently focus on measuring clinical symptoms (e.g., time-to-vomiting), which may not be subject to the same verification of standard methods and validation processes required for governmental approval processes of new and modified procedures. Biodosimeters under development have not yet been formally approved for this use. Neither set of methods has been tested in settings involving large-scale populations at risk for exposure. OBJECTIVE: To propose a framework for comparative evaluation of methods for such triage and to evaluate biodosimetric methods that are currently recommended and new methods as they are developed. METHODS: We adapt the NIH model of scientific evaluations and sciences needed for effective translational research to apply to biodosimetry for triaging very large populations following a radiation event. We detail criteria for translating basic science about dosimetry into effective multi-stage triage of large populations and illustrate it by analyzing 3 current guidelines and 3 advanced methods for biodosimetry. CONCLUSIONS: This framework for evaluating dosimetry in large populations is a useful technique to compare the strengths and weaknesses of different dosimetry methods. It can help policy-makers and planners not only to compare the methods' strengths and weaknesses for their intended use but also to develop an integrated approach to maximize their effectiveness. It also reveals weaknesses in methods that would benefit from further research and evaluation.
Collapse
Affiliation(s)
- Ann Barry Flood
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Dartmouth Medical School, Hanover, NH 03768 USA
| | - Roberto J. Nicolalde
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Dartmouth Medical School, Hanover, NH 03768 USA
| | - Eugene Demidenko
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Dartmouth Medical School, Hanover, NH 03768 USA
| | - Benjamin B. Williams
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Dartmouth Medical School, Hanover, NH 03768 USA
| | - Alla Shapiro
- Food and Drug Administration (FDA), Rockville, MD USA
| | - Albert L. Wiley
- Oak Ridge Institute for Science and Education (ORISE), Oak Ridge, TN USA
| | - Harold M. Swartz
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Dartmouth Medical School, Hanover, NH 03768 USA
| |
Collapse
|