1
|
The design of X-band EPR cavity with narrow detection aperture for in vivo fingernail dosimetry after accidental exposure to ionizing radiation. Sci Rep 2021; 11:2883. [PMID: 33558592 PMCID: PMC7870891 DOI: 10.1038/s41598-021-82462-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 01/20/2021] [Indexed: 11/13/2022] Open
Abstract
For the purpose of assessing the radiation dose of the victims involved in the nuclear emergency or radiation accident, a new type of X-band EPR resonant cavity for in vivo fingernail EPR dosimetry was designed and a homemade EPR spectrometer for in vivo fingernail detection was constructed. The microwave resonant mode of the cavity was rectangular TE101, and there was a narrow aperture for fingernail detection opened on the cavity’s wall at the position of high detection sensitivity. The DPPH dot sample and the fingernail samples were measured based on the in vivo fingernail EPR spectrometer. The measurements of the DPPH dot sample verified the preliminary functional applicable of the EPR spectrometer and illustrated the microwave power and modulation response features. The fingernails after irradiation by gamma-ray were measured and the radiation-induced signal was acquired. The results indicated that the cavity and the in vivo EPR dosimeter instrument was able to detect the radiation-induced signal in irradiated fingernail, and preliminarily verified the basic function of the instrument and its potential for emergency dose estimate after a radiation accident.
Collapse
|
2
|
The Development of an Active Learning Program for the Medical Responders in a Nuclear Disaster. Disaster Med Public Health Prep 2020; 13:853-858. [PMID: 31131778 DOI: 10.1017/dmp.2018.168] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE In Japan, with the revision of the Nuclear Emergency Response Guidelines in 2015, nuclear emergency medical assistance teams responsible for the medical treatment in the acute phase of nuclear disaster have been developed nationwide. The purpose of this research is to develop active learning materials for the education of medical staff, to confirm the educational effect of the materials, and to identify the gaps in nuclear disaster risk reduction in Japan. METHODS We established a working group and created active learning materials. We trained members of the nuclear emergency medical assistance team using the developed active learning materials and then conducted a questionnaire survey for trainees who participated in the training. RESULTS Regarding the developed teaching materials, out of 33 trainees, 33 (100%) answered "easy to understand" or "a little understandable" to the item dealing with how to use the radiation detectors and attaching/detaching personal protective equipment. Regarding the simulation about practicing hospital support and medical provision, 3 (8%) answered "a little confusing." CONCLUSION The study demonstrated that the developed materials have an educational effect. Additionally, the results of the trainee questionnaire showed the necessity for improvement in the triage system and new protocols to help both the patients and responders.
Collapse
|
3
|
Investigation of the applicability of the ESR nail dosimetry for assessment of accidental exposure in medical facilities. RADIAT MEAS 2019. [DOI: 10.1016/j.radmeas.2019.03.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
4
|
Swarts SG, Sidabras JW, Grinberg O, Tipikin DS, Kmiec M, Petryakov S, Schreiber W, Wood VA, Williams BB, Flood AB, Swartz HM. Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry. HEALTH PHYSICS 2018; 115:140-150. [PMID: 29787440 PMCID: PMC5967651 DOI: 10.1097/hp.0000000000000874] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Instrumentation and application methodologies for rapidly and accurately estimating individual ionizing radiation dose are needed for on-site triage in a radiological/nuclear event. One such methodology is an in vivo X-band, electron paramagnetic resonance, physically based dosimetry method to directly measure the radiation-induced signal in fingernails. The primary components under development are key instrument features, such as resonators with unique geometries that allow for large sampling volumes but limit radiation-induced signal measurements to the nail plate, and methodological approaches for addressing interfering signals in the nail and for calibrating dose from radiation-induced signal measurements. One resonator development highlighted here is a surface resonator array designed to reduce signal detection losses due to the soft tissues underlying the nail plate. Several surface resonator array geometries, along with ergonomic features to stabilize fingernail placement, have been tested in tissue-equivalent nail models and in vivo nail measurements of healthy volunteers using simulated radiation-induced signals in their fingernails. These studies demonstrated radiation-induced signal detection sensitivities and quantitation limits approaching the clinically relevant range of ≤ 10 Gy. Studies of the capabilities of the current instrument suggest that a reduction in the variability in radiation-induced signal measurements can be obtained with refinements to the surface resonator array and ergonomic features of the human interface to the instrument. Additional studies are required before the quantitative limits of the assay can be determined for triage decisions in a field application of dosimetry. These include expanded in vivo nail studies and associated ex vivo nail studies to provide informed approaches to accommodate for a potential interfering native signal in the nails when calculating the radiation-induced signal from the nail plate spectral measurements and to provide a method for calibrating dose estimates from the radiation-induced signal measurements based on quantifying experiments in patients undergoing total-body irradiation or total-skin electron therapy.
Collapse
Affiliation(s)
- Steven G. Swarts
- Department of Radiation Oncology, University of Florida, Gainesville, Florida 32618
| | - Jason W. Sidabras
- Max Planck for Chemical Energy Conversion, Biophysical Chemistry, Mülheim, Germany
| | - Oleg Grinberg
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | | | - Maciej Kmiec
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Sergey Petryakov
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Wilson Schreiber
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Victoria A. Wood
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | | | - Ann Barry Flood
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| | - Harold M. Swartz
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, 03755
| |
Collapse
|
5
|
Sholom S, McKeever S. Stability of X-band EPR signals from fingernails under vacuum storage. Radiat Phys Chem Oxf Engl 1993 2017; 141:78-87. [PMID: 28781435 DOI: 10.1016/j.radphyschem.2017.06.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
EPR signals of different origin have been tested in human finger- and toe-nails with an X-band EPR technique for different conditions of nail storage. Three different signals were identified, namely a singlet at g=2.005, a doublet at g=2.004 with a splitting constant A=1.8 mT, and an anisotropic signal at g1=2.057, g2=2.029 and g3=2.003 (positions of local extrema). All EPR spectra from nails, whether irradiated or mechanically stressed, can be described as a superposition of these three signals. The singlet is responsible for the background signal (BG), is the main component of radiation-induced signals (RIS) for low doses (100 Gy or lower) and also contributes to mechanically-induced signals (MIS). This signal is quite stable under vacuum storage, but can be reduced almost to zero by soaking in water. The behavior of this signal under ambient conditions depends on many factors, such as absorbed dose, air humidity, and ambient illumination intensity at the place of storage. The doublet arises after exposure of nails to high (few hundreds Gy and higher) doses or after mechanical stress of samples. Depending on how this signal was obtained, it may have bulk or surface locations with quite different stability properties. The surface-located doublet (generated on the nail edges during cutting or clipping) is quite unstable and decays over about two hours for samples stored at ambient conditions and within several seconds for samples immersed in water. The volume-distributed doublet decays within a few minutes in water, several hours at ambient conditions and several days in vacuum. The anisotropic signal may also be generated by both ionizing radiation and mechanical stress; this signal is quite stable in vacuum and decays over several days at ambient conditions or a few tens of minutes in water. The reference lines for the above-described three EPR signals were obtained and a procedure of spectra deconvolution was developed and tested on samples exposed to both ionizing radiation and mechanical stress.
Collapse
Affiliation(s)
- Sergey Sholom
- Radiation Dosimetry Group, Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA
| | - Stephen McKeever
- Radiation Dosimetry Group, Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA
| |
Collapse
|
6
|
Elajaili H, McPeak J, Romanyukha A, Aggarwal P, Eaton SS, Eaton GR. Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails. RADIATION PROTECTION DOSIMETRY 2016; 172:133-138. [PMID: 27590467 PMCID: PMC5225971 DOI: 10.1093/rpd/ncw162] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Indexed: 05/26/2023]
Abstract
X-band rapid scan electron paramagnetic resonance (EPR) measures the free radicals in irradiated clipped fingernails with higher signal-to-noise (S/N) and lower standard deviation of the signal amplitude for replicate measurements than does conventional continuous wave (CW) EPR in the same measurement time. For a clipped fingernail sample irradiated to 10 Gy and data acquisition time of 30 s with B1 = 8.5 μT, the S/N for rapid scan is >2000 for the absorption spectrum and 1200 for the corresponding first derivative. The standard deviation for replicate measurements of signal amplitude is ~1%. For CW spectra, the S/N depends on the modulation amplitude. The CW signal has a first derivative peak-to-peak linewidth of 0.95 mT. For 30 s of CW acquisition time, the S/N was 30 for a conservative modulation amplitude of 0.2 mT and B1 of 2.3 μT or 90 for a modulation amplitude of 0.4 mT and B1 of 3.2 μT, which resulted in standard deviations of replicate measurements of 5% or 2%, respectively.
Collapse
Affiliation(s)
- Hanan Elajaili
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Joseph McPeak
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | | | - Priyanka Aggarwal
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Sandra S Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Gareth R Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| |
Collapse
|
7
|
Elajaili H, McPeak J, Romanyukha A, Aggarwal P, Eaton SS, Eaton GR. Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails. RADIATION PROTECTION DOSIMETRY 2016; 172:133-138. [PMID: 27590467 DOI: 10.1093/rpd/ncw1162] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Indexed: 05/26/2023]
Abstract
X-band rapid scan electron paramagnetic resonance (EPR) measures the free radicals in irradiated clipped fingernails with higher signal-to-noise (S/N) and lower standard deviation of the signal amplitude for replicate measurements than does conventional continuous wave (CW) EPR in the same measurement time. For a clipped fingernail sample irradiated to 10 Gy and data acquisition time of 30 s with B1 = 8.5 μT, the S/N for rapid scan is >2000 for the absorption spectrum and 1200 for the corresponding first derivative. The standard deviation for replicate measurements of signal amplitude is ~1%. For CW spectra, the S/N depends on the modulation amplitude. The CW signal has a first derivative peak-to-peak linewidth of 0.95 mT. For 30 s of CW acquisition time, the S/N was 30 for a conservative modulation amplitude of 0.2 mT and B1 of 2.3 μT or 90 for a modulation amplitude of 0.4 mT and B1 of 3.2 μT, which resulted in standard deviations of replicate measurements of 5% or 2%, respectively.
Collapse
Affiliation(s)
- Hanan Elajaili
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Joseph McPeak
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | | | - Priyanka Aggarwal
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Sandra S Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| | - Gareth R Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208 USA
| |
Collapse
|
8
|
Tipikin DS, Swarts SG, Sidabras JW, Trompier F, Swartz HM. POSSIBLE NATURE OF THE RADIATION-INDUCED SIGNAL IN NAILS: HIGH-FIELD EPR, CONFIRMING CHEMICAL SYNTHESIS, AND QUANTUM CHEMICAL CALCULATIONS. RADIATION PROTECTION DOSIMETRY 2016; 172:112-120. [PMID: 27522053 PMCID: PMC5225972 DOI: 10.1093/rpd/ncw216] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Exposure of finger- and toe-nails to ionizing radiation generates an Electron Paramagnetic Resonance (EPR) signal whose intensity is dose dependent and stable at room temperature for several days. The dependency of the radiation-induced signal (RIS) on the received dose may be used as the basis for retrospective dosimetry of an individual's fortuitous exposure to ionizing radiation. Two radiation-induced signals, a quasi-stable (RIS2) and stable signal (RIS5), have been identified in nails irradiated up to a dose of 50 Gy. Using X-band EPR, both RIS signals exhibit a singlet line shape with a line width around 1.0 mT and an apparent g-value of 2.0044. In this work, we seek information on the exact chemical nature of the radiation-induced free radicals underlying the signal. This knowledge may provide insights into the reason for the discrepancy in the stabilities of the two RIS signals and help develop strategies for stabilizing the radicals in nails or devising methods for restoring the radicals after decay. In this work an analysis of high field (94 GHz and 240 GHz) EPR spectra of the RIS using quantum chemical calculations, the oxidation-reduction properties and the pH dependence of the signal intensities are used to show that spectroscopic and chemical properties of the RIS are consistent with a semiquinone-type radical underlying the RIS. It has been suggested that semiquinone radicals formed on trace amounts of melanin in nails are the basis for the RIS signals. However, based on the quantum chemical calculations and chemical properties of the RIS, it is likely that the radicals underlying this signal are generated from the radiolysis of L-3,4-dihydroxyphenylalanine (DOPA) amino acids in the keratin proteins. These DOPA amino acids are likely formed from the exogenous oxidation of tyrosine in keratin by the oxygen from the air prior to irradiation. We show that these DOPA amino acids can work as radical traps, capturing the highly reactive and unstable sulfur-based radicals and/or alkyl radicals generated during the radiation event and are converted to the more stable o-semiquinone anion-radicals. From this understanding of the oxidation-reduction properties of the RIS, it may be possible to regenerate the unstable RIS2 following its decay through treatment of nail clippings. However, the treatment used to recover the RIS2 also has the ability to recover an interfering, mechanically-induced signal (MIS) formed when the nail is clipped. Therefore, to use the recovered (regenerated) RIS2 to increase the detection limits and precision of the RIS measurements and, therefore, the dose estimates calculated from the RIS signal amplitudes, will require the application of methods to differentiate the RIS2 from the recovered MIS signal.
Collapse
Affiliation(s)
- Dmitriy S Tipikin
- EPR Center at Dartmouth, Department of Radiology, Geisel School of Medicine at Dartmouth, Lebanon, NH 03766, USA
| | - Steven G Swarts
- Department of Radiation Oncology, University of Florida, Gainesville, FL 32610, USA
| | - Jason W Sidabras
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - François Trompier
- Institut de Radioprotection et de Sûreté Nucléaire, BP 17, F-92265 Fontenay-aux-roses, France
| | - Harold M Swartz
- EPR Center at Dartmouth, Department of Radiology, Geisel School of Medicine at Dartmouth, Lebanon, NH 03766, USA
| |
Collapse
|
9
|
Bailiff I, Sholom S, McKeever S. Retrospective and emergency dosimetry in response to radiological incidents and nuclear mass-casualty events: A review. RADIAT MEAS 2016. [DOI: 10.1016/j.radmeas.2016.09.004] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
10
|
Şahiner E, Meriç N, Polymeris GS. Impact of different mechanical pre-treatment to the EPR signals of human fingernails towards studying dose response and fading subjected to UV exposure or beta irradiation. RADIAT MEAS 2015. [DOI: 10.1016/j.radmeas.2015.08.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Romanyukha A, Trompier F, Reyes RA, Christensen DM, Iddins CJ, Sugarman SL. Electron paramagnetic resonance radiation dose assessment in fingernails of the victim exposed to high dose as result of an accident. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:755-762. [PMID: 24957016 DOI: 10.1007/s00411-014-0553-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2014] [Accepted: 06/07/2014] [Indexed: 06/03/2023]
Abstract
In this paper, we report results of radiation dose measurements in fingernails of a worker who sustained a radiation injury to his right thumb while using 130 kVp X-ray for nondestructive testing. Clinically estimated absorbed dose was about 20-25 Gy. Electron paramagnetic resonance (EPR) dose assessment was independently carried out by two laboratories, the Naval Dosimetry Center (NDC) and French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). The laboratories used different equipments and protocols to estimate doses in the same fingernail samples. NDC used an X-band transportable EPR spectrometer, e-scan produced by Bruker BioSpin, and a universal dose calibration curve. In contrast, IRSN used a more sensitive Q-band stationary spectrometer (EMXplus) with a new approach for the dose assessment (dose saturation method), derived by additional dose irradiation to known doses. The protocol used by NDC is significantly faster than that used by IRSN, nondestructive, and could be done in field conditions, but it is probably less accurate and requires more sample for the measurements. The IRSN protocol, on the other hand, potentially is more accurate and requires very small amount of sample but requires more time and labor. In both EPR laboratories, the intense radiation-induced signal was measured in the accidentally irradiated fingernails and the resulting dose assessments were different. The dose on the fingernails from the right thumb was estimated as 14 ± 3 Gy at NDC and as 19 ± 6 Gy at IRSN. Both EPR dose assessments are given in terms of tissue kerma. This paper discusses the experience gained by using EPR for dose assessment in fingernails with a stationary spectrometer versus a portable one, the reasons for the observed discrepancies in dose, and potential advantages and disadvantages of each approach for EPR measurements in fingernails.
Collapse
|
12
|
He X, Swarts SG, Demidenko E, Flood AB, Grinberg O, Gui J, Mariani M, Marsh SD, Ruuge AE, Sidabras JW, Tipikin D, Wilcox DE, Swartz HM. Development and validation of an ex vivo electron paramagnetic resonance fingernail biodosimetric method. RADIATION PROTECTION DOSIMETRY 2014; 159:172-81. [PMID: 24803513 PMCID: PMC4095917 DOI: 10.1093/rpd/ncu129] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
There is an imperative need to develop methods that can rapidly and accurately determine individual exposure to radiation for screening (triage) populations and guiding medical treatment in an emergency response to a large-scale radiological/nuclear event. To this end, a number of methods that rely on dose-dependent chemical and/or physical alterations in biomaterials or biological responses are in various stages of development. One such method, ex vivo electron paramagnetic resonance (EPR) nail dosimetry using human nail clippings, is a physical biodosimetry technique that takes advantage of a stable radiation-induced signal (RIS) in the keratin matrix of fingernails and toenails. This dosimetry method has the advantages of ubiquitous availability of the dosimetric material, easy and non-invasive sampling, and the potential for immediate and rapid dose assessment. The major challenge for ex vivo EPR nail dosimetry is the overlap of mechanically induced signals and the RIS. The difficulties of analysing the mixed EPR spectra of a clipped irradiated nail were addressed in the work described here. The following key factors lead to successful spectral analysis and dose assessment in ex vivo EPR nail dosimetry: (1) obtaining a thorough understanding of the chemical nature, the decay behaviour, and the microwave power dependence of the EPR signals, as well as the influence of variation in temperature, humidity, water content, and O₂ level; (2) control of the variability among individual samples to achieve consistent shape and kinetics of the EPR spectra; (3) use of correlations between the multiple spectral components; and (4) use of optimised modelling and fitting of the EPR spectra to improve the accuracy and precision of the dose estimates derived from the nail spectra. In the work described here, two large clipped nail datasets were used to test the procedures and the spectral fitting model of the results obtained with it. A 15-donor nail set with 90 nail samples from 15 donors was used to validate the sample handling and spectral analysis methods that have been developed but without the interference of a native background signal. Good consistency has been obtained between the actual RIS and the estimated RIS computed from spectral analysis. In addition to the success in RIS estimation, a linear dose response has also been achieved for all individuals in this study, where the radiation dose ranges from 0 to 6 Gy. A second 16-donor nail set with 96 nail samples was used to test the spectral fitting model where the background signal was included during the fitting of the clipped nail spectra data. Although the dose response for the estimated and actual RIS calculated in both donor nail sets was similar, there was an increased variability in the RIS values that was likely due to the variability in the background signal between donors. Although the current methods of sample handling and spectral analysis show good potential for estimating the RIS in the EPR spectra of nail clippings, there is a remaining degree of variability in the RIS estimate that needs to be addressed; this should be achieved by identifying and accounting for demographic sources of variability in the background nail signal and the composition of the nail matrix.
Collapse
Affiliation(s)
- Xiaoming He
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA Department of Chemistry, Dartmouth College, Hanover, NH 03755, USA
| | - Steven G Swarts
- Department of Radiation Oncology, University of Florida, Gainesville, FL 32610, USA
| | - Eugene Demidenko
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Ann B Flood
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Oleg Grinberg
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Jiang Gui
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Michael Mariani
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Stephen D Marsh
- Department of Radiation Oncology, University of Florida, Gainesville, FL 32610, USA
| | - Andres E Ruuge
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Jason W Sidabras
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, WI 53213, USA
| | - Dmitry Tipikin
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| | - Dean E Wilcox
- Department of Chemistry, Dartmouth College, Hanover, NH 03755, USA
| | - Harold M Swartz
- Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA
| |
Collapse
|
13
|
Trompier F, Queinnec F, Bey E, De Revel T, Lataillade JJ, Clairand I, Benderitter M, Bottollier-Depois JF. EPR retrospective dosimetry with fingernails: report on first application cases. HEALTH PHYSICS 2014; 106:798-805. [PMID: 24776914 DOI: 10.1097/hp.0000000000000110] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
For localized irradiation to hands, in case of sources accidentally handled, it is very difficult to estimate the dose distribution by calculation. Doses may reach several tens of grays, and the dose distribution is usually very heterogeneous. Until recently, doses in such situations could be estimated only by analysis of bone biopsies using Electron Paramagnetic Resonance (EPR) spectroscopy. This technique was used previously on surgical wastes or after amputation of a finger. In this case, the dose information was available in one or a few locations on the hand only, due to the limited number of biopsy fragments usually collected. The idea to measure free radicals (FRs) induced by radiation in nails to estimate a dose is not new, but up to now, no application cases were reported. As a matter of fact, the EPR analysis of nails is complex due to the presence of intrinsic signals and parasitic signals induced by the mechanical stress (when nails are collected), which overlaps the radio-induced components. In addition, the radio-induced FRs identified up to now are unstable and very sensitive to humidity. In these conditions, it was difficult to foresee any application for dosimetry with fingernails. Recently, stable radio-induced FRs in nails has been identified and an associated protocol for dose assessment developed. This protocol has been applied by the Institut de Radioprotection et de Sûreté Nucléaire on fingernail samples from victims of three different radiological accidents that occurred between 2008 and 2012 in different places.
Collapse
Affiliation(s)
- Francois Trompier
- *Institut de Radioprotection et de Sûreté Nucléaire, IRSN, BP17, 92262 Fontenay-aux-Roses, France; †Hôpital d'Instruction des Armées Percy, Service d'Hématologie, BP 410, 92141 Clamart Cedex, France; ‡Hôpital d'Instruction des Armées Percy, Service de Chirurgie Plastique, BP 410, 92141 Clamart Cedex, France; and §Hôpital d'Instruction des Armées Percy, CTS Jean Julliard, BP 410, 92141 Clamart Cedex, France
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Trompier F, Romanyukha A, Reyes R, Vezin H, Queinnec F, Gourier D. State of the art in nail dosimetry: free radicals identification and reaction mechanisms. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:291-303. [PMID: 24469226 PMCID: PMC3996284 DOI: 10.1007/s00411-014-0512-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2013] [Accepted: 01/11/2014] [Indexed: 05/05/2023]
Abstract
Until very recently, analysis of bone biopsies by means of the method of electron paramagnetic resonance (EPR) collected after surgery or amputation has been considered as the sole reliable method for radiation dose assessment in hands and feet. EPR measurements in finger- and toenail have been considered for accident dosimetry for a long time. Human nails are very attractive biophysical materials because they are easy to collect and pertinent to whole body irradiation. Information on the existence of a radiation-induced signal in human nails has been reported almost 25 years ago. However, no practical application of EPR dosimetry on nails is known to date because, from an EPR perspective, nails represent a very complex material. In addition to the radiation-induced signal (RIS), parasitic and intense signals are induced by the mechanical stress caused when collecting nail samples (mechanically induced signals-MIS). Moreover, it has been demonstrated that the RIS stability is strongly influenced not only by temperature but also by humidity. Most studies of human nails were carried out using conventional X-band microwave band (9 GHz). Higher frequency Q-band (37 GHz) provides higher spectral resolution which allows obtaining more detailed information on the nature of different radicals in human nails. Here, we present for the first time a complete description of the different EPR signals identified in nails including parasitic, intrinsic and RIS. EPR in both X- and Q-bands was used. Four different MIS signals and five different signals specific to irradiation with ionizing radiation have been identified. The most important outcome of this work is the identification of a stable RIS component. In contrast with other identified (unstable) RIS components, this component is thermally and time stable and not affected by the physical contact of fingernails with water. A detailed description of this signal is provided here. The discovery of stable radiation-induced radical(s) associated with the RIS component mentioned opens a way for broad application of EPR dosimetry in human nails. Consequently, several recent dosimetry assessments of real accident cases have been performed based on the described measurements and analyses of this component.
Collapse
Affiliation(s)
- F Trompier
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France,
| | | | | | | | | | | |
Collapse
|
15
|
Swartz HM, Williams BB, Zaki BI, Hartford AC, Jarvis LA, Chen EY, Comi RJ, Ernstoff MS, Hou H, Khan N, Swarts SG, Flood AB, Kuppusamy P. Clinical EPR: unique opportunities and some challenges. Acad Radiol 2014; 21:197-206. [PMID: 24439333 DOI: 10.1016/j.acra.2013.10.011] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/03/2013] [Accepted: 10/14/2013] [Indexed: 11/29/2022]
Abstract
Electron paramagnetic resonance (EPR) spectroscopy has been well established as a viable technique for measurement of free radicals and oxygen in biological systems, from in vitro cellular systems to in vivo small animal models of disease. However, the use of EPR in human subjects in the clinical setting, although attractive for a variety of important applications such as oxygen measurement, is challenged with several factors including the need for instrumentation customized for human subjects, probe, and regulatory constraints. This article describes the rationale and development of the first clinical EPR systems for two important clinical applications, namely, measurement of tissue oxygen (oximetry) and radiation dose (dosimetry) in humans. The clinical spectrometers operate at 1.2 GHz frequency and use surface-loop resonators capable of providing topical measurements up to 1 cm depth in tissues. Tissue pO2 measurements can be carried out noninvasively and repeatedly after placement of an oxygen-sensitive paramagnetic material (currently India ink) at the site of interest. Our EPR dosimetry system is capable of measuring radiation-induced free radicals in the tooth of irradiated human subjects to determine the exposure dose. These developments offer potential opportunities for clinical dosimetry and oximetry, which include guiding therapy for individual patients with tumors or vascular disease by monitoring of tissue oxygenation. Further work is in progress to translate this unique technology to routine clinical practice.
Collapse
Affiliation(s)
- Harold M Swartz
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766.
| | - Benjamin B Williams
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Bassem I Zaki
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Alan C Hartford
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Lesley A Jarvis
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Eunice Y Chen
- Department of Surgery, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Richard J Comi
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Marc S Ernstoff
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Huagang Hou
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Nadeem Khan
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Steven G Swarts
- Dept. of Radiation Oncology, University of Florida, Gainesville, FL
| | - Ann B Flood
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Periannan Kuppusamy
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| |
Collapse
|
16
|
Sullivan JM, Prasanna PGS, Grace MB, Wathen L, Wallace RL, Koerner JF, Coleman CN. Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations. HEALTH PHYSICS 2013; 105:540-54. [PMID: 24162058 PMCID: PMC3810609 DOI: 10.1097/hp.0b013e31829cf221] [Citation(s) in RCA: 144] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Following a mass-casualty nuclear disaster, effective medical triage has the potential to save tens of thousands of lives. In order to best use the available scarce resources, there is an urgent need for biodosimetry tools to determine an individual's radiation dose. Initial triage for radiation exposure will include location during the incident, symptoms, and physical examination. Stepwise triage will include point of care assessment of less than or greater than 2 Gy, followed by secondary assessment, possibly with high throughput screening, to further define an individual's dose. Given the multisystem nature of radiation injury, it is unlikely that any single biodosimetry assay can be used as a standalone tool to meet the surge in capacity with the timeliness and accuracy needed. As part of the national preparedness and planning for a nuclear or radiological incident, the authors reviewed the primary literature to determine the capabilities and limitations of a number of biodosimetry assays currently available or under development for use in the initial and secondary triage of patients. Understanding the requirements from a response standpoint and the capability and logistics for the various assays will help inform future biodosimetry technology development and acquisition. Factors considered include: type of sample required, dose detection limit, time interval when the assay is feasible biologically, time for sample preparation and analysis, ease of use, logistical requirements, potential throughput, point-of-care capability, and the ability to support patient diagnosis and treatment within a therapeutically relevant time point.
Collapse
Affiliation(s)
- Julie M. Sullivan
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
- AAAS Science and Technology Policy Fellow, Washington DC
| | - Pataje G. S. Prasanna
- Radia on Research Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, MD
| | - Marcy B. Grace
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - Lynne Wathen
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - Rodney L. Wallace
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - John F. Koerner
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - C. Norman Coleman
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
- Radia on Research Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, MD
| |
Collapse
|
17
|
Swartz HM, Flood AB, Williams BB, Dong R, Swarts SG, He X, Grinberg O, Sidabras J, Demidenko E, Gui J, Gladstone DJ, Jarvis LA, Kmiec MM, Kobayashi K, Lesniewski PN, Marsh SDP, Matthews TP, Nicolalde RJ, Pennington PM, Raynolds T, Salikhov I, Wilcox DE, Zaki BI. Electron paramagnetic resonance dosimetry for a large-scale radiation incident. HEALTH PHYSICS 2012; 103:255-67. [PMID: 22850230 PMCID: PMC3649772 DOI: 10.1097/hp.0b013e3182588d92] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.
Collapse
|