1
|
Abdoli MA, Hassanvand M, Nejatbakhsh N. Monte Carlo Model Validation of 6MV Beam of OMID, the First Iranian Linear Accelerator. JOURNAL OF MEDICAL SIGNALS & SENSORS 2024; 14:22. [PMID: 39234590 PMCID: PMC11373786 DOI: 10.4103/jmss.jmss_54_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 12/30/2023] [Accepted: 02/12/2024] [Indexed: 09/06/2024]
Abstract
Monte Carlo (MC) techniques are regarded as an accurate method to simulate the dose calculation in radiotherapy for many years. The present paper aims to validate the simulated model of the 6-MV beam of OMID linear accelerator (BEHYAAR Company) by EGSnrc codes system and also investigate the effects of initial electron beam parameters (energy, radial full width at half maximum, and mean angular spread) on dose distributions. For this purpose, the comparison between the calculated and measured percentage depth dose (PDD) and lateral dose profiles was done by gamma index (GI) with 1%-1 mm acceptance criteria. MC model validating was done for 3 cm × 3 cm, 5 cm × 5 cm, 8 cm × 8 cm, 10 cm × 10 cm, and 20 cm × 20 cm field sizes. To study the sensitivity of model to beam parameters, the field size was selected as 10 cm × 10 cm and 30 cm × 30 cm. All lateral dose profiles were obtained at 10 cm. Excellent agreement was achieved with a 99.2% GI passing percentage for PDD curves and at least 93.8% GI for lateral dose profiles for investigated field sizes. Our investigation confirmed that the lateral dose profile severely depends on the considered source parameters in this study. PDD only considerably depends on the initial electron beam energy. Therefore, source parameters should not be specified independently. These results indicate that the current model of OMID 6-MV Linac is well established, and the accuracy of the simulation is high enough to be used in various applications.
Collapse
Affiliation(s)
| | - Maryam Hassanvand
- Department of Physics, Isfahan University of Technology, Isfahan, Iran
| | | |
Collapse
|
2
|
Effects of low-energy electron beam irradiation on the shelf-life and quality of vacuum-packaged beef steaks during chilled storage. Meat Sci 2022; 193:108932. [DOI: 10.1016/j.meatsci.2022.108932] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/02/2022] [Accepted: 07/30/2022] [Indexed: 01/08/2023]
|
3
|
Tugrul T. Comparison of Monaco treatment planning system algorithms and Monte Carlo simulation for small fields in anthropomorphic RANDO phantom: The esophagus case. J Cancer Res Ther 2021; 17:1370-1375. [PMID: 34916367 DOI: 10.4103/jcrt.jcrt_1143_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Background In this study, the dose distributions obtained by the algorithms used in Monaco treatment planning system (TPS) and Monte Carlo (MC) simulation were compared for small fields in the anthropomorphic RANDO phantom, and then, the results were analyzed using the gamma analysis method. Materials and Methods In the study, dose distributions obtained from the collapse cone algorithm, MC algorithm, and MC simulation were examined. The EGSnrc was utilized for MC simulation. Results In radiation fields smaller than 3 cm × 3 cm, the doses calculated by the CC algorithm are particularly high in the region of lung/soft-tissue interfaces. In the region of soft-tissue/vertebral interfaces, the doses calculated by the CC algorithm and the MC algorithm are compatible with the MC simulation. For each algorithm, the main reason for the non-overlapping dose curves in small fields compared to MC simulation is that the lateral electronic equilibrium loss is not taken into account by the algorithms. Conclusion The doses calculated by the algorithms used in TPS may differ, especially in environments where density changes are sharp. Even if the radiation dose from different angles is calculated similarly in the target area by the algorithms, the calculated doses in the tissues in each radiation field path may be different. Therefore, to increase the quality of radiotherapy and to protect critical organs more accurately, the accuracy of the algorithms in TPS should be checked before treatment, especially in multi-field treatments such as stereotactic body radiation therapy and intensity-modulated radiotherapy for tumors in the abdominal region.
Collapse
Affiliation(s)
- Taylan Tugrul
- Department of Radiation Oncology, Medicine Faculty of Van Yüzüncü Yıl University, Van, Turkey
| |
Collapse
|
4
|
Three-dimensional IMRT QA of Monte Carlo and full scatter convolution algorithms based on 3D film dosimetry. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109528] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
5
|
Choi MG, Law M, Yoon DK, Tamura M, Matsumoto K, Otsuka M, Kim MS, Djeng SK, Monzen H, Suh TS. Simplified sigmoidal curve fitting for a 6 MV FFF photon beam of the Halcyon to determine the field size for beam commissioning and quality assurance. Radiat Oncol 2020; 15:273. [PMID: 33287828 PMCID: PMC7720380 DOI: 10.1186/s13014-020-01709-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 11/06/2020] [Indexed: 11/22/2022] Open
Abstract
Background An O-ring gantry-type linear accelerator (LINAC) with a 6-MV flattening filter-free (FFF) photon beam, Halcyon, includes a reference beam that contains representative information such as the percent depth dose, profile and output factor for commissioning and quality assurance. However, because it does not provide information about the field size, we proposed a method to determine all field sizes according to all depths for radiation therapy using simplified sigmoidal curve fitting (SCF). Methods After mathematical definition of the SCF using four coefficients, the defined curves were fitted to both the reference data (RD) and the measured data (MD). For good agreement between the fitting curve and the profiles in each data set, the field sizes were determined by identifying the maximum point along the third derivative of the fitting curve. The curve fitting included the field sizes for beam profiles of 2 × 2, 4 × 4, 6 × 6, 8 × 8, 10 × 10, 20 × 20 and 28 × 28 cm2 as a function of depth (at 1.3, 5, 10 and 20 cm). The field size results from the RD were compared with the results from the MD using the same condition. Results All fitting curves show goodness of fit, R2, values that are greater than 0.99. The differences in field size between the RD and the MD were within the range of 0 to 0.2 cm. The smallest difference in the field sizes at a depth of 10 cm, which is a surface-to-axis distance, was reported. Conclusion Application of the SCF method has been proven to accurately capture the field size of the preconfigured RD and the measured FFF photon beam data for the Halcyon system. The current work can be useful for beam commissioning as a countercheck methodology to determine the field size from RD in the treatment planning system of a newly installed Halcyon system and for routine quality assurance to ascertain the correctness of field sizes for clinical use of the Halcyon system.
Collapse
Affiliation(s)
- Min-Geon Choi
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Martin Law
- Proton Therapy Pte Ltd., 1 Biopolis Drive, Singapore, 138622, Singapore
| | - Do-Kun Yoon
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Mikoto Tamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan
| | - Kenji Matsumoto
- Department of Radiology, Kindai University Hospital, Osaka-Sayama-Shi, 377-2, Ono-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan
| | - Masakazu Otsuka
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan
| | - Moo-Sub Kim
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Shih-Kien Djeng
- Proton Therapy Pte Ltd., 1 Biopolis Drive, Singapore, 138622, Singapore
| | - Hajime Monzen
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan.
| | - Tae Suk Suh
- Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
| |
Collapse
|
6
|
Bajwa S, Gul A, Ahmed S, Kakakhel MB. Monte Carlo commissioning of radiotherapy LINAC-Introducing an improved methodology. Rep Pract Oncol Radiother 2020; 25:720-724. [PMID: 32684860 DOI: 10.1016/j.rpor.2020.06.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/18/2020] [Accepted: 06/23/2020] [Indexed: 11/15/2022] Open
Abstract
Purpose Monte Carlo (MC) commissioning of medical linear accelerator (LINAC) is a time-consuming process involving a comparison between measured and simulated cross beam/lateral profiles and percentage depth doses (PDDs) for various field sizes. An agreement between these two data sets is sought by trial and error method while varying the incident electron beam parameters, such as electron beam energy or width, etc. This study aims to improve the efficiency of MC commissioning of a LINAC by assessing the feasibility of using a limited number of simulated PDDs. Materials and methods Using EGSnrc codes, a Varian Clinac 2100 unit has been commissioned for 6 MV photon beam, and a methodology has been proposed to identify the incident electron beam parameters in a speedier fashion. Impact of voxel size in 3-dimensions and cost functions used for comparison of the measured and simulated data have been investigated along with the role of interpolation. Results A voxel size of 1 × 1×0.5 cm3 has been identified as suitable for accurate and fast commissioning of the LIANC. The optimum number of simulated PDDs (required for further interpolation) has been found to be five. Conclusion The present study suggests that PDDs alone at times can be insufficient for an unambiguous commissioning process and should be supported by including the lateral beam profiles in the process.
Collapse
Affiliation(s)
- Saqib Bajwa
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Attia Gul
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Shahbaz Ahmed
- Wayne State University School of Medicine Gershenson Radiation Oncology Center Karmanos Cancer Institute, 4100 John R, Detroit, MI 48201.,Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| | - Muhammad B Kakakhel
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering & Applied Sciences (PIEAS), Nilore, Islamabad, Pakistan
| |
Collapse
|
7
|
Tuğrul T, Eroğul O. Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam. Rep Pract Oncol Radiother 2019; 24:331-337. [PMID: 31193931 DOI: 10.1016/j.rpor.2019.05.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 03/01/2019] [Accepted: 05/11/2019] [Indexed: 10/26/2022] Open
Abstract
Aim In this study, we investigated initial electron parameters of Siemens Artiste Linac with 6 MV photon beam using the Monte Carlo method. Background It is essential to define all the characteristics of initial electrons hitting the target, i.e. mean energy and full width of half maximum (FWHM) of the spatial distribution intensity, which is needed to run Monte Carlo simulations. The Monte Carlo is the most accurate method for simulation of radiotherapy treatments. Materials and methods Linac head geometry was modeled using the BEAMnrc code. The phase space files were used as input file to DOSXYZnrc simulation to determine the dose distribution in a water phantom. We obtained percent depth dose curves and the lateral dose profile. All the results were obtained at 100 cm of SSD and for a 10 × 10 cm2 field. Results We concluded that there existed a good conformity between Monte Carlo simulation and measurement data when we used electron mean energy of 6.3 MeV and 0.30 cm FWHM value as initial parameters. We observed that FWHM values had very little effect on PDD and we found that the electron mean energy and FWHM values affected the lateral dose profile. However, these effects are between tolerance values. Conclusions The initial parameters especially depend on components of a linac head. The phase space file which was obtained from Monte Carlo Simulation for a linac can be used as calculation of scattering, MLC leakage, to compare dose distribution on patients and in various studies.
Collapse
Affiliation(s)
- Taylan Tuğrul
- Department of Radiation Oncology, Medicine Faculty of Van Yüzüncü Yıl University, Van, Turkey
| | - Osman Eroğul
- Department of Biomedical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| |
Collapse
|
8
|
Najafzadeh M, Hoseini-Ghafarokhi M, Bolagh RSM, Haghparast M, Zarifi S, Nickfarjam A, Farhood B, Chow JCL. Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18MV photon beam: Determination of initial electron beam parameters. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:1047-1070. [PMID: 31498147 DOI: 10.3233/xst-190568] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
OBJECTIVE This study aims to benchmark a Monte Carlo (MC) model of the 18 MV photon beam produced by the Siemens Oncor® linac using the BEAMnrc and DOSXYZnrc codes. METHODS By matching the percentage depth doses and beam profiles calculated by MC simulations with measurements, the initial electron beam parameters including electron energy, full width at half maximum (spatial FWHM), and mean angular spread were derived for the 10×10 cm2 and 20×20 cm2 field sizes. The MC model of the 18 MV photon beam was then validated against the measurements for different field sizes (5×5, 30×30 and 40×40 cm2) by gamma index analysis. RESULTS The optimum values for electron energy, spatial FWHM and mean angular spread were 14.2 MeV, 0.08 cm and 0.8 degree, respectively. The MC simulations yielded the comparable measurement results of these optimum parameters. The gamma passing rates (with acceptance criteria of 1% /1 mm) for percentage depth doses were found to be 100% for all field sizes. For cross-line profiles, the gamma passing rates were 100%, 97%, 95%, 96% and 95% for 5×5, 10×10, 20×20, 30×30 and 40×40 cm2 field sizes, respectively. CONCLUSIONS By validation of the MC model of Siemens Oncor® linac using various field sizes, it was found that both dose profiles of small and large field sizes were very sensitive to the changes in spatial FWHM and mean angular spread of the primary electron beam from the bending magnet. Hence, it is recommended that both small and large field sizes of the 18 MV photon beams should be considered in the Monte Carlo linac modeling.
Collapse
Affiliation(s)
- Milad Najafzadeh
- Department of Radiology, Faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare-Abbas, Iran
| | - Mojtaba Hoseini-Ghafarokhi
- Department of Radiology and Nuclear Medicine, School of Para Medical Science, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | | | - Mohammad Haghparast
- Department of Radiology, Faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare-Abbas, Iran
| | - Shiva Zarifi
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Abolfazl Nickfarjam
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Bagher Farhood
- Department of Medical Physics and Radiology, Faculty of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
| | - James C L Chow
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
- Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| |
Collapse
|
9
|
Mohammed M, El Bardouni T, Chakir E, Boukhal H, Saeed M, Ahmed AA. Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2017.11.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.02.029] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
11
|
Chang KP, Chen LY, Chien YH. Monte Carlo simulation of linac irradiation with dynamic wedges. RADIATION PROTECTION DOSIMETRY 2014; 162:24-28. [PMID: 25004937 DOI: 10.1093/rpd/ncu211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This study aims to simulate the dose distributions of LINAC with dynamic wedges (DWs) under various field sizes and wedge angles by the BEAMnrc code with DYNJAWS component module. These were compared with those calculated by the treatment planning system (TPS) and the measured data. All percentage depth doses (PDDs) were found to be in good agreement between TPS, Monte Carlo (MC) and measurements made in open fields and fields with DWs. For dose profiles, compared with the MC and the measurements, TPS gives reliable results for large field sizes (>10 × 10 cm(2)) but results in significant errors in small field sizes (5 × 5 cm(2)). The entrance surface doses calculated by TPS were found to be significantly overestimated. For depths deeper than 0.5 cm, TPS yields PDDs in agreement with MC simulations.
Collapse
Affiliation(s)
- Kwo-Ping Chang
- Department of Medical Imaging and Radiological Sciences and Institute of Radiological Sciences, Tzu Chi College of Technology, 880, Section 2, Chien-Kuo Road, Hualien 970, Taiwan
| | - Lu-Yu Chen
- Department of Radiology, Lotung Poh-Ai Hospital, 83, Nanchang Street, Luodong Township, Yilan County 265, Taiwan
| | - Yu-Huang Chien
- Department of Radiation Therapy, Mennonite Christian Hospital, 44, Min-chuan Road, Hualien 970, Taiwan
| |
Collapse
|
12
|
Dosimetric distribution of the surroundings of different dental crowns and implants during LINAC photon irradiation. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2013.11.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|