1
|
ABSTRACTS (BY NUMBER). Tissue Eng Part A 2022. [DOI: 10.1089/ten.tea.2022.29025.abstracts] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
2
|
Boffito M, Servello L, Arango-Ospina M, Miglietta S, Tortorici M, Sartori S, Ciardelli G, Boccaccini AR. Custom-Made Poly(urethane) Coatings Improve the Mechanical Properties of Bioactive Glass Scaffolds Designed for Bone Tissue Engineering. Polymers (Basel) 2021; 14:151. [PMID: 35012176 PMCID: PMC8747464 DOI: 10.3390/polym14010151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 12/03/2022] Open
Abstract
The replication method is a widely used technique to produce bioactive glass (BG) scaffolds mimicking trabecular bone. However, these scaffolds usually exhibit poor mechanical reliability and fast degradation, which can be improved by coating them with a polymer. In this work, we proposed the use of custom-made poly(urethane)s (PURs) as coating materials for 45S5 Bioglass®-based scaffolds. In detail, BG scaffolds were dip-coated with two PURs differing in their soft segment (poly(ε-caprolactone) or poly(ε-caprolactone)/poly(ethylene glycol) 70/30 w/w) (PCL-PUR and PCL/PEG-PUR) or PCL (control). PUR-coated scaffolds exhibited biocompatibility, high porosity (ca. 91%), and improved mechanical properties compared to BG scaffolds (2-3 fold higher compressive strength). Interestingly, in the case of PCL-PUR, compressive strength significantly increased by coating BG scaffolds with an amount of polymer approx. 40% lower compared to PCL/PEG-PUR- and PCL-coated scaffolds. On the other hand, PEG presence within PCL/PEG-PUR resulted in a fast decrease in mechanical reliability in an aqueous environment. PURs represent promising coating materials for BG scaffolds, with the additional pros of being ad-hoc customized in their physico-chemical properties. Moreover, PUR-based coatings exhibited high adherence to the BG surface, probably because of the formation of hydrogen bonds between PUR N-H groups and BG surface functionalities, which were not formed when PCL was used.
Collapse
Affiliation(s)
- Monica Boffito
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
| | - Lucia Servello
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
| | - Marcela Arango-Ospina
- Institute of Biomaterials, University of Erlangen-Nuremberg, Cauerstr. 6, 91058 Erlangen, Germany;
| | - Serena Miglietta
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
| | - Martina Tortorici
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
- Julius Wolff Institut, Charité—Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Susanna Sartori
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy; (L.S.); (S.M.); (M.T.); (S.S.); (G.C.)
| | - Aldo R. Boccaccini
- Institute of Biomaterials, University of Erlangen-Nuremberg, Cauerstr. 6, 91058 Erlangen, Germany;
| |
Collapse
|
3
|
Colucci F, Mancini V, Mattu C, Boffito M. Designing Multifunctional Devices for Regenerative Pharmacology Based on 3D Scaffolds, Drug-Loaded Nanoparticles, and Thermosensitive Hydrogels: A Proof-of-Concept Study. Pharmaceutics 2021; 13:pharmaceutics13040464. [PMID: 33808138 PMCID: PMC8066789 DOI: 10.3390/pharmaceutics13040464] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/18/2021] [Accepted: 03/22/2021] [Indexed: 12/25/2022] Open
Abstract
Regenerative pharmacology combines tissue engineering/regenerative medicine (TERM) with drug delivery with the aim to improve the outcomes of traditional TERM approaches. In this work, we aimed to design a multicomponent TERM platform comprising a three-dimensional scaffold, a thermosensitive hydrogel, and drug-loaded nanoparticles. We used a thermally induced phase separation method to obtain scaffolds with anisotropic mechanical properties, suitable for soft tissue engineering. A thermosensitive hydrogel was developed using a Poloxamer® 407-based poly(urethane) to embed curcumin-loaded nanoparticles, obtained by the single emulsion nanoprecipitation method. We found that encapsulated curcumin could retain its antioxidant activity and that embedding nanoparticles within the hydrogel did not affect the hydrogel gelation kinetics nor the possibility to progressively release the drug. The porous scaffold was easily loaded with the hydrogel, resulting in significantly enhanced (4-fold higher) absorption of a model molecule of nutrients (fluorescein isothiocyanate dextran 4kDa) from the surrounding environment compared to pristine scaffold. The developed platform could thus represent a valuable alternative in the treatment of many pathologies affecting soft tissues, by concurrently exploiting the therapeutic effects of drugs, with the 3D framework acting as a physical support for tissue regeneration and the cell-friendly environment represented by the hydrogel.
Collapse
Affiliation(s)
- Francesco Colucci
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy; (F.C.); (V.M.)
| | - Vanessa Mancini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy; (F.C.); (V.M.)
- Department of Anatomy & Embryology, Leiden University Medical Center, 2333 ZC Leiden, The Netherlands
| | - Clara Mattu
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy; (F.C.); (V.M.)
- PolitoBIOMed Laboratory, Politecnico di Torino, 10129 Turin, Italy
- Correspondence: (C.M.); (M.B.)
| | - Monica Boffito
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy; (F.C.); (V.M.)
- PolitoBIOMed Laboratory, Politecnico di Torino, 10129 Turin, Italy
- Institute for Chemical-Physical Processes, National Research Council (CNR-IPCF), 56124 Pisa, Italy
- Correspondence: (C.M.); (M.B.)
| |
Collapse
|
4
|
Herzberger J, Sirrine JM, Williams CB, Long TE. Polymer Design for 3D Printing Elastomers: Recent Advances in Structure, Properties, and Printing. Prog Polym Sci 2019. [DOI: 10.1016/j.progpolymsci.2019.101144] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
5
|
Boffito M, Di Meglio F, Mozetic P, Giannitelli SM, Carmagnola I, Castaldo C, Nurzynska D, Sacco AM, Miraglia R, Montagnani S, Vitale N, Brancaccio M, Tarone G, Basoli F, Rainer A, Trombetta M, Ciardelli G, Chiono V. Surface functionalization of polyurethane scaffolds mimicking the myocardial microenvironment to support cardiac primitive cells. PLoS One 2018; 13:e0199896. [PMID: 29979710 PMCID: PMC6034803 DOI: 10.1371/journal.pone.0199896] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 06/15/2018] [Indexed: 11/28/2022] Open
Abstract
Scaffolds populated with human cardiac progenitor cells (CPCs) represent a therapeutic opportunity for heart regeneration after myocardial infarction. In this work, square-grid scaffolds are prepared by melt-extrusion additive manufacturing from a polyurethane (PU), further subjected to plasma treatment for acrylic acid surface grafting/polymerization and finally grafted with laminin-1 (PU-LN1) or gelatin (PU-G) by carbodiimide chemistry. LN1 is a cardiac niche extracellular matrix component and plays a key role in heart formation during embryogenesis, while G is a low-cost cell-adhesion protein, here used as a control functionalizing molecule. X-ray photoelectron spectroscopy analysis shows nitrogen percentage increase after functionalization. O1s and C1s core-level spectra and static contact angle measurements show changes associated with successful functionalization. ELISA assay confirms LN1 surface grafting. PU-G and PU-LN1 scaffolds both improve CPC adhesion, but LN1 functionalization is superior in promoting proliferation, protection from apoptosis and expression of differentiation markers for cardiomyocytes, endothelial and smooth muscle cells. PU-LN1 and PU scaffolds are biodegraded into non-cytotoxic residues. Scaffolds subcutaneously implanted in mice evoke weak inflammation and integrate with the host tissue, evidencing a significant blood vessel density around the scaffolds. PU-LN1 scaffolds show their superiority in driving CPC behavior, evidencing their promising role in myocardial regenerative medicine.
Collapse
Affiliation(s)
- Monica Boffito
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Franca Di Meglio
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Pamela Mozetic
- Department of Engineering, Tissue Engineering Unit, Università Campus Bio-Medico di Roma, Rome, Italy
- Center for Translational Medicine, International Clinical Research Center, St.Anne’s University Hospital, Brno, Czechia
| | - Sara Maria Giannitelli
- Department of Engineering, Tissue Engineering Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Irene Carmagnola
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Clotilde Castaldo
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Daria Nurzynska
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Anna Maria Sacco
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Rita Miraglia
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Stefania Montagnani
- Department of Public Health, University of Naples ‘Federico II’, Naples, Italy
| | - Nicoletta Vitale
- Department of Molecular Biotechnology and Health Sciences, University of Turin, Turin, Italy
| | - Mara Brancaccio
- Department of Molecular Biotechnology and Health Sciences, University of Turin, Turin, Italy
| | - Guido Tarone
- Department of Molecular Biotechnology and Health Sciences, University of Turin, Turin, Italy
| | - Francesco Basoli
- Department of Engineering, Tissue Engineering Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Alberto Rainer
- Department of Engineering, Tissue Engineering Unit, Università Campus Bio-Medico di Roma, Rome, Italy
- Institute for Photonics and Nanotechnology, National Research Council, Rome, Italy
| | - Marcella Trombetta
- Department of Engineering, Tissue Engineering Unit, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Valeria Chiono
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
6
|
Vozzi F, Logrand F, Cabiati M, Cicione C, Boffito M, Carmagnola I, Vitale N, Gori M, Brancaccio M, Del Ry S, Gastaldi D, Cattarinuzzi E, Vena P, Rainer A, Domenici C, Ciardelli G, Sartori S. Biomimetic engineering of the cardiac tissue through processing, functionalization, and biological characterization of polyester urethanes. ACTA ACUST UNITED AC 2018; 13:055006. [PMID: 29869614 DOI: 10.1088/1748-605x/aaca5b] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Three-dimensional (3D) tissue models offer new tools in the study of diseases. In the case of the engineering of cardiac muscle, a realistic goal would be the design of a scaffold able to replicate the tissue-specific architecture, mechanical properties, and chemical composition, so that it recapitulates the main functions of the tissue. This work is focused on the design and preliminary biological validation of an innovative polyester urethane (PUR) scaffold mimicking cardiac tissue properties. The porous scaffold was fabricated by thermally induced phase separation (TIPS) from poly(ε-caprolactone) diol, 1,4-butanediisocyanate, and l-lysine ethyl ester. Morphological and mechanical scaffolds characterization was accomplished by confocal microscopy, and micro-tensile and compression techniques. Scaffolds were then functionalized with fibronectin by plasma treatment, and the surface treatment was studied by x-ray photoelectron spectroscopy, attenuated total reflectance Fourier transform infrared spectra, and contact angle measurements. Primary rat neonatal cardiomyocytes were seeded on scaffolds, and their colonization, survival, and beating activity were analyzed for 14 days. Signal transduction pathways and apoptosis involved in cells, the structural development of the heart, and its metabolism were analyzed. PUR scaffolds showed a porous-aligned structure and mechanical properties consistent with that of the myocardial tissue. Cardiomyocytes plated on the scaffolds showed a high survival rate and a stable beating activity. Serine/threonine kinase (AKT) and extracellular signal-regulated kinases (ERK) phosphorylation was higher in cardiomyocytes cultured on the PUR scaffold compared to those on tissue culture plates. Real-time polymerase chain reaction analysis showed a significant modulation at 14 days of cardiac muscle (MYH7, prepro-ET-1), hypertrophy-specific (CTGF), and metabolism-related (SLC2a1, PFKL) genes in PUR scaffolds.
Collapse
Affiliation(s)
- Federico Vozzi
- Institute of Clinical Physiology, IFC-CNR, Via Moruzzi 1, I-56124 Pisa, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Imre B, Gojzewski H, Check C, Chartoff R, Vancso GJ. Properties and Phase Structure of Polycaprolactone-Based Segmented Polyurethanes with Varying Hard and Soft Segments: Effects of Processing Conditions. MACROMOL CHEM PHYS 2017. [DOI: 10.1002/macp.201700214] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Balazs Imre
- School of Chemical Biological and Environmental Engineering; Oregon State University; Corvallis OR 97331 USA
| | - Hubert Gojzewski
- Materials Science and Technology of Polymers; Faculty of Science and Technology; University of Twente; Drienerlolaan 5 7522 NB Enschede The Netherlands
| | - Casey Check
- Center for Advanced Materials Characterization in Oregon (CAMCOR); University of Oregon; Eugene OR 97403 USA
| | - Richard Chartoff
- School of Chemical Biological and Environmental Engineering; Oregon State University; Corvallis OR 97331 USA
| | - G. Julius Vancso
- Materials Science and Technology of Polymers; Faculty of Science and Technology; University of Twente; Drienerlolaan 5 7522 NB Enschede The Netherlands
| |
Collapse
|
8
|
Caddeo S, Boffito M, Sartori S. Tissue Engineering Approaches in the Design of Healthy and Pathological In Vitro Tissue Models. Front Bioeng Biotechnol 2017; 5:40. [PMID: 28798911 PMCID: PMC5526851 DOI: 10.3389/fbioe.2017.00040] [Citation(s) in RCA: 144] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Accepted: 06/26/2017] [Indexed: 12/16/2022] Open
Abstract
In the tissue engineering (TE) paradigm, engineering and life sciences tools are combined to develop bioartificial substitutes for organs and tissues, which can in turn be applied in regenerative medicine, pharmaceutical, diagnostic, and basic research to elucidate fundamental aspects of cell functions in vivo or to identify mechanisms involved in aging processes and disease onset and progression. The complex three-dimensional (3D) microenvironment in which cells are organized in vivo allows the interaction between different cell types and between cells and the extracellular matrix, the composition of which varies as a function of the tissue, the degree of maturation, and health conditions. In this context, 3D in vitro models can more realistically reproduce a tissue or organ than two-dimensional (2D) models. Moreover, they can overcome the limitations of animal models and reduce the need for in vivo tests, according to the "3Rs" guiding principles for a more ethical research. The design of 3D engineered tissue models is currently in its development stage, showing high potential in overcoming the limitations of already available models. However, many issues are still opened, concerning the identification of the optimal scaffold-forming materials, cell source and biofabrication technology, and the best cell culture conditions (biochemical and physical cues) to finely replicate the native tissue and the surrounding environment. In the near future, 3D tissue-engineered models are expected to become useful tools in the preliminary testing and screening of drugs and therapies and in the investigation of the molecular mechanisms underpinning disease onset and progression. In this review, the application of TE principles to the design of in vitro 3D models will be surveyed, with a focus on the strengths and weaknesses of this emerging approach. In addition, a brief overview on the development of in vitro models of healthy and pathological bone, heart, pancreas, and liver will be presented.
Collapse
Affiliation(s)
- Silvia Caddeo
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
- Department of Oral Cell Biology, Academic Center for Dentistry Amsterdam, Amsterdam, Netherlands
| | - Monica Boffito
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Susanna Sartori
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
9
|
Singh C, Wang X. Metal Ion-Loaded Nanofibre Matrices for Calcification Inhibition in Polyurethane Implants. J Funct Biomater 2017. [PMID: 28644382 PMCID: PMC5618273 DOI: 10.3390/jfb8030022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Pathologic calcification leads to structural deterioration of implant materials via stiffening, stress cracking, and other structural disintegration mechanisms, and the effect can be critical for implants intended for long-term or permanent implantation. This study demonstrates the potential of using specific metal ions (MI)s for inhibiting pathological calcification in polyurethane (PU) implants. The hypothesis of using MIs as anti-calcification agents was based on the natural calcium-antagonist role of Mg2+ ions in human body, and the anti-calcification effect of Fe3+ ions in bio-prosthetic heart valves has previously been confirmed. In vitro calcification results indicated that a protective covering mesh of MI-doped PU can prevent calcification by preventing hydroxyapatite crystal growth. However, microstructure and mechanical characterisation revealed oxidative degradation effects from Fe3+ ions on the mechanical properties of the PU matrix. Therefore, from both a mechanical and anti-calcification effects point of view, Mg2+ ions are more promising candidates than Fe3+ ions. The in vitro MI release experiments demonstrated that PU microphase separation and the structural design of PU-MI matrices were important determinants of release kinetics. Increased phase separation in doped PU assisted in consistent long-term release of dissolved MIs from both hard and soft segments of the PU. The use of a composite-sandwich mesh design prevented an initial burst release which improved the late (>20 days) release rate of MIs from the matrix.
Collapse
Affiliation(s)
- Charanpreet Singh
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
| | - Xungai Wang
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
- School of Textile Science and Engineering, Wuhan Textile University, Wuhan 430073, China.
| |
Collapse
|
10
|
Gojzewski H, Imre B, Check C, Chartoff R, Vancso J. Mechanical mapping and morphology across the length scales unveil structure-property relationships in polycaprolactone based polyurethanes. ACTA ACUST UNITED AC 2016. [DOI: 10.1002/polb.24140] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Hubert Gojzewski
- Materials Science and Technology of Polymers, Faculty of Science and Technology; University of Twente; Enschede 7522 NB The Netherlands
| | - Balazs Imre
- School of Chemical, Biological and Environmental Engineering; Oregon State University; Corvallis Oregon 97331
| | - Casey Check
- Center for Advanced Materials Characterization in Oregon (CAMCOR); University of Oregon; Eugene Oregon 97405
| | - Richard Chartoff
- School of Chemical, Biological and Environmental Engineering; Oregon State University; Corvallis Oregon 97331
| | - Julius Vancso
- Materials Science and Technology of Polymers, Faculty of Science and Technology; University of Twente; Enschede 7522 NB The Netherlands
| |
Collapse
|
11
|
Santurdes N, González-Gómez A, Martín del Campo-Fierro M, Rosales-Ibáñez R, Oros-Ovalle C, Vázquez-Lasa B, San Román J. Development of bioresorbable bilayered systems for application as affordable wound dressings. J BIOACT COMPAT POL 2016. [DOI: 10.1177/0883911516635840] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The objective of this work was the preparation and evaluation of a bioresorbable bilayered system for application in the treatment of dermal lesions. The system was based on a polyesterurethane as the external layer and a gelatin membrane as the internal layer. The polyesterurethane was synthesized from poly(ε-caprolactone), polyethylene glycol of 1 or 10 kDa as a hydrophilic component or Pluronic F127 as an amphiphilic component and l-lysine ethyl ester diisocyanate as an urethane precursor. Gelatin membrane was obtained by crosslinking with the naturally occurring crosslinker genipin. Three important points were addressed in this study: the physicochemical characterization of the system, the in vitro behaviour and the in vivo performance on a full-thickness wound defect of rat. The polyesterurethane containing polyethylene glycol of 10 kDa presented the optimum properties for the designed application as to be tested in animal experiments. The in vivo results showed good healing of the lesion with the formation of epidermis similar to normal rat skin. These promising results suggest the potential of this system to be used as an affordable wound dressing in the treatment of different dermal lesions.
Collapse
Affiliation(s)
- N Santurdes
- Institute of Polymer Science and Technology, CSIC, Madrid, Spain
| | - A González-Gómez
- Institute of Polymer Science and Technology, CSIC, Madrid, Spain
- CIBER, Carlos III Health Institute, Madrid, Spain
| | | | - R Rosales-Ibáñez
- Faculty of Stomatology, Autonomous University of San Luis Potosi, San Luis Potosi, Mexico
| | - C Oros-Ovalle
- Faculty of Medicine, Autonomous University of San Luis Potosi and Hospital Central ‘Dr. Ignacio Morones Prieto’, San Luis Potosi, Mexico
| | - B Vázquez-Lasa
- Institute of Polymer Science and Technology, CSIC, Madrid, Spain
- CIBER, Carlos III Health Institute, Madrid, Spain
| | - J San Román
- Institute of Polymer Science and Technology, CSIC, Madrid, Spain
- CIBER, Carlos III Health Institute, Madrid, Spain
| |
Collapse
|
12
|
Su WF, Ho CC, Shih TH, Wang CH, Yeh CH. Exceptional biocompatibility of 3D fibrous scaffold for cardiac tissue engineering fabricated from biodegradable polyurethane blended with cellulose. INT J POLYM MATER PO 2016. [DOI: 10.1080/00914037.2016.1157802] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Wei-Fang Su
- Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan
- Molecular Image Center, National Taiwan University, Taipei, Taiwan
- Institute of Polymer Science and Engineering, National Taiwan University, Taipei, Taiwan
| | - Chun-Chih Ho
- Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan
- Molecular Image Center, National Taiwan University, Taipei, Taiwan
| | - Tzu-Hsiang Shih
- Institute of Polymer Science and Engineering, National Taiwan University, Taipei, Taiwan
| | - Chen-Hua Wang
- Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan
- Molecular Image Center, National Taiwan University, Taipei, Taiwan
| | - Chun-Hao Yeh
- Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
13
|
Brannigan RP, Walder A, Dove AP. Tunable Thermoplastic Poly(ester–urethane)s Based on Modified Serinol Extenders. Macromolecules 2016. [DOI: 10.1021/acs.macromol.5b02531] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Ruairí P. Brannigan
- Department
of Chemistry, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
| | - Anthony Walder
- The Lubrizol Corporation, 207 Lowell Street, Wilmington, Massachusetts 01887, United States
| | - Andrew P. Dove
- Department
of Chemistry, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
14
|
Boffito M, Gioffredi E, Chiono V, Calzone S, Ranzato E, Martinotti S, Ciardelli G. Novel polyurethane-based thermosensitive hydrogels as drug release and tissue engineering platforms: design and in vitro
characterization. POLYM INT 2016. [DOI: 10.1002/pi.5080] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Monica Boffito
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Emilia Gioffredi
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Valeria Chiono
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Stefano Calzone
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Elia Ranzato
- Dipartimento di Scienze e Innovazione Tecnologica; University of Piemonte Orientale; Viale T. Michel 11 15121 Alessandria Italy
| | - Simona Martinotti
- Dipartimento di Scienze e Innovazione Tecnologica; University of Piemonte Orientale; Viale T. Michel 11 15121 Alessandria Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
- CNR-IPCF UOS Pisa; Via Moruzzi 1 56124 Pisa Italy
| |
Collapse
|
15
|
Ionic cross‐linking of water‐soluble polyurethane improves protein encapsulation and release. Eng Life Sci 2015. [DOI: 10.1002/elsc.201400188] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
16
|
Boffito M, Bernardi E, Sartori S, Ciardelli G, Sassi MP. A mechanical characterization of polymer scaffolds and films at the macroscale and nanoscale. J Biomed Mater Res A 2014; 103:162-9. [PMID: 24610888 DOI: 10.1002/jbm.a.35147] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2013] [Revised: 01/13/2014] [Accepted: 02/21/2014] [Indexed: 12/11/2022]
Abstract
Biomaterials should be mechanically tested at both the nanoscale and macroscale under conditions simulating their working state, either in vitro or in vivo, to confirm their applicability in tissue engineering applications. In this article, polyester-urethane-based films and porous scaffolds produced by hot pressing and thermally induced phase separation respectively, were mechanically characterized at both the macroscale and nanoscale by tensile tests and indentation-type atomic force microscopy. All tests were conducted in wet state with the final aim of simulating scaffold real operating conditions. The films showed two distinct Young Moduli populations, which can be ascribed to polyurethane hard and soft segments. In the scaffold, the application of a thermal cooling gradient during phase separation was responsible for a nanoscale polymer chain organization in a preferred direction. At the macroscale, the porous matrices showed a Young Modulus of about 1.5 MPa in dry condition and 0.3 MPa in wet state. The combination of nanoscale and macroscale values as well as the aligned structure are in accordance with stiffness and structure required for scaffolds used for the regeneration of soft tissues such as muscles.
Collapse
Affiliation(s)
- Monica Boffito
- Dipartimento di Ingegneria Meccanica e Aerospaziale, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Torino, Italy
| | | | | | | | | |
Collapse
|
17
|
Chiono V, Mozetic P, Boffito M, Sartori S, Gioffredi E, Silvestri A, Rainer A, Giannitelli SM, Trombetta M, Nurzynska D, Di Meglio F, Castaldo C, Miraglia R, Montagnani S, Ciardelli G. Polyurethane-based scaffolds for myocardial tissue engineering. Interface Focus 2014; 4:20130045. [PMID: 24501673 DOI: 10.1098/rsfs.2013.0045] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Bi-layered scaffolds with a 0°/90° lay-down pattern were prepared by melt-extrusion additive manufacturing (AM) using a poly(ester urethane) (PU) synthesized from poly(ε-caprolactone) diol, 1,4-butandiisocyanate and l-lysine ethyl ester dihydrochloride chain extender. Rheological analysis and differential scanning calorimetry of the starting material showed that compression moulded PU films were in the molten state at a higher temperature than 155°C. The AM processing temperature was set at 155°C after verifying the absence of PU thermal degradation phenomena by isothermal thermogravimetry analysis and rheological characterization performed at 165°C. Scaffolds highly reproduced computer-aided design geometry and showed an elastomeric-like behaviour which is promising for applications in myocardial regeneration. PU scaffolds supported the adhesion and spreading of human cardiac progenitor cells (CPCs), whereas they did not stimulate CPC proliferation after 1-14 days culture time. In the future, scaffold surface functionalization with bioactive peptides/proteins will be performed to specifically guide CPC behaviour.
Collapse
Affiliation(s)
- Valeria Chiono
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| | - Pamela Mozetic
- Tissue Engineering Laboratory , Università 'Campus Bio-Medico di Roma' , Via Alvaro del Portillo 21, Rome , Italy
| | - Monica Boffito
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| | - Susanna Sartori
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| | - Emilia Gioffredi
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| | - Antonella Silvestri
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| | - Alberto Rainer
- Tissue Engineering Laboratory , Università 'Campus Bio-Medico di Roma' , Via Alvaro del Portillo 21, Rome , Italy
| | - Sara Maria Giannitelli
- Tissue Engineering Laboratory , Università 'Campus Bio-Medico di Roma' , Via Alvaro del Portillo 21, Rome , Italy
| | - Marcella Trombetta
- Tissue Engineering Laboratory , Università 'Campus Bio-Medico di Roma' , Via Alvaro del Portillo 21, Rome , Italy
| | - Daria Nurzynska
- Department of Public Health , University of Naples 'Federico II' , Via Pansini 5, Naples , Italy
| | - Franca Di Meglio
- Department of Public Health , University of Naples 'Federico II' , Via Pansini 5, Naples , Italy
| | - Clotilde Castaldo
- Department of Public Health , University of Naples 'Federico II' , Via Pansini 5, Naples , Italy
| | - Rita Miraglia
- Department of Public Health , University of Naples 'Federico II' , Via Pansini 5, Naples , Italy
| | - Stefania Montagnani
- Department of Public Health , University of Naples 'Federico II' , Via Pansini 5, Naples , Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering , Politecnico di Torino , Corso Duca degli Abruzzi 24, Turin , Italy
| |
Collapse
|
18
|
Silvestri A, Sartori S, Boffito M, Mattu C, Di Rienzo AM, Boccafoschi F, Ciardelli G. Biomimetic myocardial patches fabricated with poly(ɛ-caprolactone) and polyethylene glycol-based polyurethanes. J Biomed Mater Res B Appl Biomater 2013; 102:1002-13. [DOI: 10.1002/jbm.b.33081] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Revised: 09/06/2013] [Accepted: 11/19/2013] [Indexed: 11/05/2022]
Affiliation(s)
- Antonella Silvestri
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| | - Susanna Sartori
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| | - Monica Boffito
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| | - Clara Mattu
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| | - Anna M. Di Rienzo
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| | - Francesca Boccafoschi
- Health Sciences Department; School of Medicine; University of Eastern Piedmont; Novara Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Torino Italy
| |
Collapse
|
19
|
Boffito M, Sartori S, Ciardelli G. Polymeric scaffolds for cardiac tissue engineering: requirements and fabrication technologies. POLYM INT 2013. [DOI: 10.1002/pi.4608] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Monica Boffito
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Susanna Sartori
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Corso Duca degli Abruzzi 24 10129 Turin Italy
- CNR-IPCF UOS Pisa; Via Moruzzi 1 56124 Pisa Italy
| |
Collapse
|