1
|
Darquenne C, Corcoran TE, Lavorini F, Sorano A, Usmani OS. The effects of airway disease on the deposition of inhaled drugs. Expert Opin Drug Deliv 2024; 21:1175-1190. [PMID: 39136493 PMCID: PMC11412782 DOI: 10.1080/17425247.2024.2392790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 05/06/2024] [Accepted: 08/12/2024] [Indexed: 08/15/2024]
Abstract
INTRODUCTION The deposition of inhaled medications is the first step in the pulmonary pharmacokinetic process to produce a therapeutic response. Not only lung dose but more importantly the distribution of deposited drug in the different regions of the lung determines local bioavailability, efficacy, and clinical safety. Assessing aerosol deposition patterns has been the focus of intense research that combines the fields of physics, radiology, physiology, and biology. AREAS COVERED The review covers the physics of aerosol transport in the lung, experimental, and in-silico modeling approaches to determine lung dose and aerosol deposition patterns, the effect of asthma, chronic obstructive pulmonary disease, and cystic fibrosis on aerosol deposition, and the clinical translation potential of determining aerosol deposition dose. EXPERT OPINION Recent advances in in-silico modeling and lung imaging have enabled the development of realistic subject-specific aerosol deposition models, albeit mainly in health. Accurate modeling of lung disease still requires additional refinements in existing imaging and modeling approaches to better characterize disease heterogeneity in peripheral airways. Nevertheless, recent patient-centric innovation in inhaler device engineering and the incorporation of digital technology have led to more consistent lung deposition and improved targeting of the distal airways, which better serve the clinical needs of patients.
Collapse
Affiliation(s)
- Chantal Darquenne
- Department of Medicine, University of California, San Diego, CA, USA
| | | | - Federico Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Alessandra Sorano
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London, London, UK
| |
Collapse
|
2
|
Feng Z, Han Z, Wang Y, Guo H, Liu J. Comparison of the Application of Vibrating Mesh Nebulizer and Jet Nebulizer in Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-analysis. Int J Chron Obstruct Pulmon Dis 2024; 19:829-839. [PMID: 38562440 PMCID: PMC10984201 DOI: 10.2147/copd.s452191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 03/24/2024] [Indexed: 04/04/2024] Open
Abstract
Objective To comparison of the application of Vibrating Mesh Nebulizer and Jet Nebulizer in chronic obstructive pulmonary disease (COPD). Research Methods This systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) statements. The primary outcome measures analyzed included: The amount of inhaler in the urine sample at 30 minutes after inhalation therapy (USAL0.5), The total amount of inhaler in urine sample within 24 hours (USAL24), Aerosol emitted, Forced expiratory volume in 1 second (FEV1), Forced vital capacity (FVC). Results Ten studies were included with a total of 314 study participants, including 157 subjects in the VMN group and 157 subjects in the JN group. The data analysis results of USAL0.5, MD (1.88 [95% CI, 0.95 to 2.81], P = 0.000), showed a statistically significant difference. USAL24, MD (1.61 [95% CI, 1.14 to 2.09], P = 0.000), showed a statistically significant difference. The results of aerosol emitted showed a statistically significant difference in MD (3.44 [95% CI, 2.84 to 4.04], P = 0.000). The results of FEV1 showed MD (0.05 [95% CI, -0.24 to 0.35], P=0.716), the results were not statistically significant. The results of FVC showed MD (0.11 [95% CI, -0.18 to 0.41], P=0.459), the results were not statistically significant. It suggests that VMN is better than JN and provides higher aerosols, but there is no difference in improving lung function between them. Conclusion VMN is significantly better than JN in terms of drug delivery and utilization in the treatment of patients with COPD. However, in the future use of nebulizers, it is important to select a matching nebulizer based on a combination of factors such as mechanism of action of the nebulizer, disease type and comorbidities, ventilation strategies and modes, drug formulations, as well as cost-effectiveness, in order to achieve the ideal treatment of COPD.
Collapse
Affiliation(s)
- Zhouzhou Feng
- The First Clinical Medical College of Lanzhou University, Lanzhou City, People’s Republic of China
| | - Zhengcai Han
- The First Clinical Medical College of Lanzhou University, Lanzhou City, People’s Republic of China
| | - Yaqin Wang
- The First Clinical Medical College of Lanzhou University, Lanzhou City, People’s Republic of China
| | - Hong Guo
- The First Clinical Medical College of Lanzhou University, Lanzhou City, People’s Republic of China
| | - Jian Liu
- The First Clinical Medical College of Lanzhou University, Lanzhou City, People’s Republic of China
- Gansu Maternal and Child Health Hospital/Gansu Central Hospital, Lanzhou City, People’s Republic of China
| |
Collapse
|
3
|
Hong SW, Chang KH, Woo CJ, Kim HC, Kwak BS, Park BJ, Nam KC. Evaluation of antibody drug delivery efficiency via nebulizer in various airway models and breathing patterns. BMC Pharmacol Toxicol 2023; 24:70. [PMID: 38041207 PMCID: PMC10691028 DOI: 10.1186/s40360-023-00711-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 11/22/2023] [Indexed: 12/03/2023] Open
Abstract
BACKGROUND Nebulizers are commonly used to treat respiratory diseases, which are a major cause of morbidity and mortality. While inhalation therapy with antibodies has been evaluated in preclinical studies and clinical trials for respiratory diseases, it has not yet been approved for treatment. Moreover, there is limited information regarding the delivery efficiency of therapeutic antibodies via nebulizer. METHODS In this study, the nebulization characteristics and drug delivery efficiencies were compared when immunoglobulin G (IgG) was delivered by five nebulizers using two airway models and five breathing patterns. The study confirmed that the delivered dose and drug delivery efficiency were reduced in the child model compared to those in the adult model and in the asthma pattern compared to those in the normal breathing pattern. RESULTS The NE-SM1 NEPLUS vibrating mesh nebulizer demonstrated the highest delivery efficiency when calculated as a percentage of the loading dose, whereas the PARI BOY SX + LC SPRINT (breath-enhanced) jet nebulizer had the highest delivery efficiency when calculated as a percentage of the emitted dose. CONCLUSION The results suggest that the total inspiration volume, output rate, and particle size should be considered when IgG nebulization is used. We, therefore, propose a method for evaluating the efficiency of nebulizer for predicting antibody drug delivery.
Collapse
Affiliation(s)
- Soon Woo Hong
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, 10326, Gyeonggi-do, Korea
| | - Kyung Hwa Chang
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, 10326, Gyeonggi-do, Korea
| | - Chang Jae Woo
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, 10326, Gyeonggi-do, Korea
- Office of Technology Transfer, National Cancer Center, Goyang-si, 10408, Gyeonggi-do, Korea
| | - Ho Chul Kim
- Department of Radiological Science, Eulji University, Seongnam-si, 13135, Gyeonggi-do, Korea
| | - Bong Seop Kwak
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, 10326, Gyeonggi-do, Korea
| | - Bong Joo Park
- Department of Electrical & Biological Physics and Institute of Biomaterials, Kwangwoon University, Seoul, 01897, Korea
| | - Ki Chang Nam
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, 10326, Gyeonggi-do, Korea.
| |
Collapse
|
4
|
Park HM, Chang KH, Moon SH, Park BJ, Yoo SK, Nam KC. In vitro delivery efficiencies of nebulizers for different breathing patterns. Biomed Eng Online 2021; 20:59. [PMID: 34112170 PMCID: PMC8194228 DOI: 10.1186/s12938-021-00895-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Nebulizers are medical devices that deliver aerosolized medication directly to lungs to treat a variety of respiratory diseases. However, breathing patterns, respiration rates, airway diameters, and amounts of drugs delivered by nebulizers may be respiratory disease dependent. METHOD In this study, we developed a respiratory simulator consisting of an airway model, an artificial lung, a flow sensor, and an aerosol collecting filter. Various breathing patterns were generated using a linear actuator and an air cylinder. We tested six home nebulizers (jet (2), static (2), and vibrating mesh nebulizers (2)). Nebulizers were evaluated under two conditions, that is, for the duration of nebulization and at a constant output 1.3 mL using four breathing patterns, namely, the breathing pattern specified in ISO 27427:2013, normal adult, asthmatic, and COPD. RESULTS One of the vibrating mesh nebulizers had the highest dose delivery efficiency. The drug delivery efficiencies of nebulizers were found to depend on breathing patterns. CONCLUSION We suggest a quantitative drug delivery efficiency evaluation method and calculation parameters that include considerations of constant outputs and residual volumes. The study shows output rates and breathing patterns should be considered when the drug delivery efficiencies of nebulizers are evaluated.
Collapse
Affiliation(s)
- Hyun Mok Park
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea
- Graduate Program of Biomedical Engineering, Yonsei University, Seoul, South Korea
| | - Kyung Hwa Chang
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea
| | - Sang-Hyub Moon
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea
- Graduate Program of Biomedical Engineering, Yonsei University, Seoul, South Korea
| | - Bong Joo Park
- Department of Electrical & Biological Physics, Kwangwoon University, Seoul, South Korea
- Institute of Biomaterials, Kwangwoon University, Seoul, South Korea
| | - Sun Kook Yoo
- Graduate Program of Biomedical Engineering, Yonsei University, Seoul, South Korea
- Department of Medical Engineering, Yonsei University College of Medicine, Seoul, South Korea
| | - Ki Chang Nam
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea
| |
Collapse
|
5
|
Ari A. A path to successful patient outcomes through aerosol drug delivery to children: a narrative review. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:593. [PMID: 33987291 PMCID: PMC8105845 DOI: 10.21037/atm-20-1682] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 07/03/2020] [Indexed: 11/06/2022]
Abstract
Although using aerosolized medications is a mainstay of treatment in children with asthma and other respiratory diseases, there are many issues in terms of device and interface selection, delivery technique and dosing, as well as patient and parental education that have not changed for half a century. Also, due to many aerosol devices and interfaces available on the market and the broad range of patient characteristics and requirements, providing effective aerosol therapy to children becomes a challenge. While aerosol delivery devices are equally effective, if they are age-appropriate and used correctly, the majority of aerosol devices require multiple steps to be used efficiently. Unfortunately, many children with pulmonary diseases have problems with the correct delivery technique and do not gain therapeutic benefits from therapy that result in poor disease management and increased healthcare costs. Therefore, the purpose of this paper is to review the current knowledge on aerosol delivery devices used in children and guide clinicians on the optimum device- and interface-selection, delivery technique, and dosing in this patient population. Strategies on how to deliver aerosolized medications in crying and distressed children and how to educate parents on aerosol therapy and promote patient adherence to prescribed medications are also provided. Future directions of aerosol therapy in children should focus on these issues and implement policies and clinical practices that highlight the potential solutions to these problems.
Collapse
Affiliation(s)
- Arzu Ari
- Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| |
Collapse
|
6
|
Bass K, Farkas D, Hassan A, Bonasera S, Hindle M, Longest PW. High-Efficiency Dry Powder Aerosol Delivery to Children: Review and Application of New Technologies. JOURNAL OF AEROSOL SCIENCE 2021; 153:105692. [PMID: 33716317 PMCID: PMC7945982 DOI: 10.1016/j.jaerosci.2020.105692] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
While dry powder aerosol formulations offer a number of advantages, their use in children is often limited due to poor lung delivery efficiency and difficulties with consistent dry powder inhaler (DPI) usage. Both of these challenges can be attributed to the typical use of adult devices in pediatric subjects and a lack of pediatric-specific DPI development. In contrast, a number of technologies have recently been developed or progressed that can substantially improve the efficiency and reproducibility of DPI use in children including: (i) nose-to-lung administration with small particles, (ii) active positive-pressure devices, (iii) structures to reduce turbulence and jet momentum, and (iv) highly dispersible excipient enhanced growth particle formulations. In this study, these technologies and their recent development are first reviewed in depth. A case study is then considered in which these technologies are simultaneously applied in order to enable the nose-to-lung administration of dry powder aerosol to children with cystic fibrosis (CF). Using a combination of computational fluid dynamics (CFD) analysis and realistic in vitro experiments, device performance, aerosol size increases and lung delivery efficiency are considered for pediatric-CF subjects in the age ranges of 2-3, 5-6 and 9-10 years old. Results indicate that a new 3D rod array structure significantly improves performance of a nasal cannula reducing interface loss by a factor of 1.5-fold and produces a device emitted mass median aerodynamic diameter (MMAD) of 1.67 μm. For all ages considered, approximately 70% of the loaded dose reaches the lower lung beyond the lobar bronchi. Moreover, significant and rapid size increase of the aerosol is observed beyond the larynx and illustrates the potential for targeting lower airway deposition. In conclusion, concurrent CFD and realistic in vitro analysis indicates that a combination of multiple new technologies can be implemented to overcome obstacles that currently limit the use of DPIs in children as young as two years of age.
Collapse
Affiliation(s)
- Karl Bass
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
| | - Dale Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
| | - Amr Hassan
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
7
|
Chang KH, Moon SH, Yoo SK, Park BJ, Nam KC. Aerosol Delivery of Dornase Alfa Generated by Jet and Mesh Nebulizers. Pharmaceutics 2020; 12:pharmaceutics12080721. [PMID: 32751886 PMCID: PMC7463544 DOI: 10.3390/pharmaceutics12080721] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/29/2020] [Accepted: 07/29/2020] [Indexed: 11/23/2022] Open
Abstract
Recent reports on mesh nebulizers suggest the possibility of stable nebulization of various therapeutic protein drugs. In this study, the in vitro performance and drug stability of jet and mesh nebulizers were examined for dornase alfa and compared with respect to their lung delivery efficiency in BALB/c mice. We compared four nebulizers: two jet nebulizers (PARI BOY SX with red and blue nozzles), a static mesh nebulizer (NE-U150), and a vibrating mesh nebulizer (NE-SM1). The enzymatic activity of dornase alfa was assessed using a kinetic fluorometric DNase activity assay. Both jet nebulizers had large residual volumes between 24% and 27%, while the volume of the NE-SM1 nebulizer was less than 2%. Evaluation of dornase alfa aerosols produced by the four nebulizers showed no overall loss of enzymatic activity or protein content and no increase in aggregation or degradation. The amount of dornase alfa delivered to the lungs was highest for the PARI BOY SX-red jet nebulizer. This result confirmed that aerosol droplet size is an important factor in determining the efficiency of dornase alfa delivery to the lungs. Further clinical studies and analysis are required before any conclusions can be drawn regarding the clinical safety and efficacy of these nebulizers.
Collapse
Affiliation(s)
- Kyung Hwa Chang
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea; (K.H.C.); (S.-H.M.)
| | - Sang-Hyub Moon
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea; (K.H.C.); (S.-H.M.)
| | - Sun Kook Yoo
- Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Korea;
| | - Bong Joo Park
- Department of Electrical & Biological Physics, Kwangwoon University, Seoul 01897, Korea
- Institute of Biomaterials, Kwangwoon University, Seoul 01897, Korea
- Correspondence: (B.J.P.); (K.C.N.); Tel.: +82-2-940-8629 (B.J.P.); +82-31-961-5802 (K.C.N.)
| | - Ki Chang Nam
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea; (K.H.C.); (S.-H.M.)
- Correspondence: (B.J.P.); (K.C.N.); Tel.: +82-2-940-8629 (B.J.P.); +82-31-961-5802 (K.C.N.)
| |
Collapse
|
8
|
Farkas D, Hindle M, Bonasera S, Bass K, Longest W. Development of an Inline Dry Powder Inhaler for Oral or Trans-Nasal Aerosol Administration to Children. J Aerosol Med Pulm Drug Deliv 2019; 33:83-98. [PMID: 31464559 DOI: 10.1089/jamp.2019.1540] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Background: Dry powder inhalers (DPIs) offer a number of advantages, such as rapid delivery of high-dose inhaled medications; however, DPI use in children is often avoided due to low lung delivery efficiency and difficulty in operating the device. The objective of this study was to develop a high-efficiency inline DPI for administering aerosol therapy to children with the option of using either an oral or trans-nasal approach. Methods: An inline DPI was developed that consisted of hollow inlet and outlet capillaries, a powder chamber, and a nasal or oral interface. A ventilation bag or compressed air was used to actuate the device and simultaneously provide a full deep inspiration consistent with a 5-year-old child. The powder chamber was partially filled with a model spray-dried excipient enhanced growth powder formulation with a mass of 10 mg. Device aerosolization was characterized with cascade impaction, and aerosol transmissions through oral and nasal in vitro models were assessed. Results: Best device performance was achieved when all actuation air passed through the powder chamber (no bypass flow) resulting in an aerosol mean mass median aerodynamic diameter (MMAD) <1.75 μm and a fine particle fraction (<5 μm) ≥90% based on emitted dose. Actuation with the ventilation bag enabled lung delivery efficiency through the nasal and oral interfaces to a tracheal filter of 60% or greater, based on loaded dose. In both oral and nose-to-lung (N2L) administrations, extrathoracic depositional losses were <10%. Conclusion: In conclusion, this study has proposed and initially developed an efficient inline DPI for delivering spray-dried formulations to children using positive pressure operation. Actuation of the device with positive pressure enabled effective N2L aerosol administration with a DPI, which may be beneficial for subjects who are too young to use a mouthpiece or to simultaneously treat the nasal and lung airways of older children.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Worth Longest
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
9
|
Chang KH, Moon SH, Oh JY, Yoon YS, Gu N, Lim CY, Park BJ, Nam KC. Comparison of Salbutamol Delivery Efficiency for Jet versus Mesh Nebulizer Using Mice. Pharmaceutics 2019; 11:pharmaceutics11040192. [PMID: 31010218 PMCID: PMC6523426 DOI: 10.3390/pharmaceutics11040192] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 04/11/2019] [Accepted: 04/17/2019] [Indexed: 11/16/2022] Open
Abstract
Recent reports using a breathing simulator system have suggested that mesh nebulizers provide more effective medication delivery than jet nebulizers. In this study, the performances of jet and mesh nebulizers were evaluated by comparing their aerosol drug delivery efficiencies in mice. We compared four home nebulizers: two jet nebulizers (PARI BOY SX with red and blue nozzles), a static mesh nebulizer (NE-U22), and a vibrating mesh nebulizer (NE-SM1). After mice were exposed to salbutamol aerosol, the levels of salbutamol in serum and lung were estimated by ELISA. The residual volume of salbutamol was the largest at 34.6% in PARI BOY SX, while the values for NE-U22 and NE-SM1 mesh nebulizers were each less than 1%. The salbutamol delivery efficiencies of NE-U22 and NE-SM1 were higher than that of PARI BOY SX, as the total delivered amounts of lung and serum were 39.9% and 141.7% as compared to PARI BOY SX, respectively. The delivery efficiency of the mesh nebulizer was better than that of the jet nebulizer. Although the jet nebulizer can generate smaller aerosol particles than the mesh nebulizer used in this study, the output rate of the jet nebulizer is low, resulting in lower salbutamol delivery efficiency. Therefore, clinical validation of the drug delivery efficiency according to nebulizer type is necessary to avoid overdose and reduced drug wastage.
Collapse
Affiliation(s)
- Kyung Hwa Chang
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Sang-Hyub Moon
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Jin Young Oh
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Young-Soon Yoon
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Namyi Gu
- Department of Clinical Pharmacology and Therapeutics, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Chi-Yeon Lim
- Department of Biostatistics, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Bong Joo Park
- Department of Electrical Biological Physics and Institute of Biomaterials, Kwangwoon University, Seoul 01897, Korea.
| | - Ki Chang Nam
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| |
Collapse
|
10
|
Larios Mora A, Detalle L, Gallup JM, Van Geelen A, Stohr T, Duprez L, Ackermann MR. Delivery of ALX-0171 by inhalation greatly reduces respiratory syncytial virus disease in newborn lambs. MAbs 2019; 10:778-795. [PMID: 29733750 PMCID: PMC6150622 DOI: 10.1080/19420862.2018.1470727] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Respiratory syncytial virus (RSV) is a common cause of acute lower respiratory disease in infants and young children worldwide. Currently, treatment is supportive and no vaccines are available. The use of newborn lambs to model hRSV infection in human infants may provide a valuable tool to assess safety and efficacy of new antiviral drugs and vaccines. ALX-0171 is a trivalent Nanobody targeting the hRSV fusion (F) protein and its therapeutic potential was evaluated in newborn lambs infected with a human strain of RSV followed by daily ALX-0171 nebulization for 3 or 5 consecutive days. Colostrum-deprived newborn lambs were infected with hRSV-M37 before being treated by daily nebulization with either ALX-0171 or placebo. Two different treatment regimens were examined: day 1–5 or day 3–5 post-infection. Lambs were monitored daily for general well-being and clinical parameters. Respiratory tissues and bronchoalveolar lavage fluid were collected at day 6 post-inoculation for the quantification of viral lesions, lung viral titers, viral antigen and lung histopathology. Administration by inhalation of ALX-0171 was well-tolerated in these hRSV-infected newborn lambs. Robust antiviral effects and positive effects on hRSV-induced lung lesions and reduction in symptoms of illness were noted. These effects were still apparent when treatment start was delayed and coincided with peak viral loads (day 3 post-infection) and at a time point when signs of RSV disease were apparent. The latter design is expected to have high translational value for planned clinical trials. These results are indicative of the therapeutic potential of ALX-0171 in infants.
Collapse
Affiliation(s)
- Alejandro Larios Mora
- a College of Veterinary Medicine, Department of Veterinary Pathology , Iowa State University , Ames , IA , USA
| | | | - Jack M Gallup
- a College of Veterinary Medicine, Department of Veterinary Pathology , Iowa State University , Ames , IA , USA
| | - Albert Van Geelen
- a College of Veterinary Medicine, Department of Veterinary Pathology , Iowa State University , Ames , IA , USA
| | | | | | - Mark R Ackermann
- a College of Veterinary Medicine, Department of Veterinary Pathology , Iowa State University , Ames , IA , USA
| |
Collapse
|
11
|
Longest PW, Bass K, Dutta R, Rani V, Thomas ML, El-Achwah A, Hindle M. Use of computational fluid dynamics deposition modeling in respiratory drug delivery. Expert Opin Drug Deliv 2019; 16:7-26. [PMID: 30463458 PMCID: PMC6529297 DOI: 10.1080/17425247.2019.1551875] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 11/20/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Respiratory drug delivery is a surprisingly complex process with a number of physical and biological challenges. Computational fluid dynamics (CFD) is a scientific simulation technique that is capable of providing spatially and temporally resolved predictions of many aspects related to respiratory drug delivery from initial aerosol formation through respiratory cellular drug absorption. AREAS COVERED This review article focuses on CFD-based deposition modeling applied to pharmaceutical aerosols. Areas covered include the development of new complete-airway CFD deposition models and the application of these models to develop a next-generation of respiratory drug delivery strategies. EXPERT OPINION Complete-airway deposition modeling is a valuable research tool that can improve our understanding of pharmaceutical aerosol delivery and is already supporting medical hypotheses, such as the expected under-treatment of the small airways in asthma. These complete-airway models are also being used to advance next-generation aerosol delivery strategies, like controlled condensational growth. We envision future applications of CFD deposition modeling to reduce the need for human subject testing in developing new devices and formulations, to help establish bioequivalence for the accelerated approval of generic inhalers, and to provide valuable new insights related to drug dissolution and clearance leading to microdosimetry maps of drug absorption.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Rabijit Dutta
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Vijaya Rani
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Morgan L. Thomas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Ahmad El-Achwah
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
12
|
Farkas D, Hindle M, Longest PW. Development of an Inline Dry Powder Inhaler That Requires Low Air Volume. J Aerosol Med Pulm Drug Deliv 2017; 31:255-265. [PMID: 29261454 DOI: 10.1089/jamp.2017.1424] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Inline dry powder inhalers (DPIs) are actuated by an external air source and have distinct advantages for delivering aerosols to infants and children, and to individuals with compromised lung function or who require ventilator support. However, current inline DPIs either perform poorly, are difficult to operate, and/or require large volumes (∼1 L) of air. The objective of this study was to develop and characterize a new inline DPI for aerosolizing spray-dried formulations with powder masses of 10 mg and higher using a dispersion air volume of 10 mL per actuation that is easy to load (capsule-based) and operate. METHODS Primary features of the new low air volume (LV) DPIs are fixed hollow capillaries that both pierce the capsule and provide a continuous flow path for air and aerosol passing through the device. Two different configurations were evaluated, which were a straight-through (ST) device, with the inlet and outlet capillaries on opposite ends of the capsule, and a single-sided (SS) device, with both the inlet and outlet capillaries on the same side of the capsule. The devices were operated with five actuations of a 10 mL air syringe using an albuterol sulfate (AS) excipient-enhanced growth (EEG) formulation. Device emptying and aerosol characteristics were evaluated for multiple device outlet configurations. RESULTS Each device had specific advantages. The best case ST device produced the smallest aerosol [mean mass median aerodynamic diameter (MMAD) = 1.57 μm; fine particle fraction <5 μm (FPF<5μm) = 95.2%)] but the mean emitted dose (ED) was 61.9%. The best case SS device improved ED (84.8%), but produced a larger aerosol (MMAD = 2.13 μm; FPF<5μm = 89.3%) that was marginally higher than the initial deaggregation target. CONCLUSIONS The new LV-DPIs produced an acceptable high-quality aerosol with only 10 mL of dispersion air per actuation and were easy to load and operate. This performance should enable application in high and low flow mechanical ventilation systems and high efficiency lung delivery to both infants and children.
Collapse
Affiliation(s)
- Dale Farkas
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia
| | - Michael Hindle
- 2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| | - P Worth Longest
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia.,2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| |
Collapse
|
13
|
Shinta Devi NLP, Nurhaeni N, Hayati H. Effect of Audiovisual Distraction on Distress and Oxygenation Status in Children Receiving Aerosol Therapy. Compr Child Adolesc Nurs 2017; 40:14-21. [DOI: 10.1080/24694193.2017.1386966] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
| | - Nani Nurhaeni
- Faculty of Nursing Universitas Indonesia, Jalan Bahder Djohan Campus, Depok, Indonesia
| | - Happy Hayati
- Faculty of Nursing Universitas Indonesia, Jalan Bahder Djohan Campus, Depok, Indonesia
| |
Collapse
|
14
|
Pourchez J, Leclerc L, Sarry G, Vergnon JM, Dubus JC. [Bench-test evaluation of spacer devices for fluticasone delivery to infants]. Rev Mal Respir 2016; 34:29-35. [PMID: 27155896 DOI: 10.1016/j.rmr.2016.02.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 02/26/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Use of a spacer device to optimize the delivery of fluticasone to infants with asthma is an important issue and clinicians require guidance around the choice of device. This in vitro study characterizes the particle size and the fluticasone delivery via 9 spacers. METHODS We used an in vitro infant nasal cast with two different inspiratory flow rates (50 and 100mL/s). Fluticasone particle size in the aerosol was evaluated by laser diffractometry and tracheal deposition by spectrophotometric assay. RESULTS Significant differences in particle size were observed between the 9 spacers (similar D50 but D90 from 5.65±0.65 to 8.80±1.35μm). A 75 % or higher respirable fraction was obtained for only 5 spacers. The 50mL/s flow rate lead to the best drug delivery. At this flow, OptiChamber® (62±3 %) and Vortex® (91±8.5 %) had a tracheal deposition over 50 % of the initial dose of fluticasone, although the 7 other spacers exhibited a fluticasone deposition less than 25 %. DISCUSSION This study shows a wide variation of drug delivery between the 9 spacers studied. We demonstrate that a low inspiratory flow and a spacer showing antistatic properties facilitate drug delivery.
Collapse
Affiliation(s)
- J Pourchez
- École nationale supérieure des Mines de Saint-Étienne, CIS-EMSE, Sainbiose, 42023 Saint-Étienne, France; Inserm, U1059, Sainbiose, 42023 Saint-Étienne, France; Université de Lyon, 42023 Saint-Étienne, France.
| | - L Leclerc
- École nationale supérieure des Mines de Saint-Étienne, CIS-EMSE, Sainbiose, 42023 Saint-Étienne, France; Inserm, U1059, Sainbiose, 42023 Saint-Étienne, France; Université de Lyon, 42023 Saint-Étienne, France
| | - G Sarry
- École nationale supérieure des Mines de Saint-Étienne, CIS-EMSE, Sainbiose, 42023 Saint-Étienne, France; Inserm, U1059, Sainbiose, 42023 Saint-Étienne, France; Université de Lyon, 42023 Saint-Étienne, France
| | - J-M Vergnon
- Inserm, U1059, Sainbiose, 42023 Saint-Étienne, France; Université de Lyon, 42023 Saint-Étienne, France; Service de pneumologie, CHU de Saint-Étienne, 42055 Saint-Étienne, France
| | - J C Dubus
- Unité de pneumopédiatrie, CHU Timone-Enfants, 13385 Marseille cedex 5, France
| |
Collapse
|