1
|
Ursem RFR, Steijlen A, Parrilla M, Bastemeijer J, Bossche A, De Wael K. Worth your sweat: wearable microfluidic flow rate sensors for meaningful sweat analytics. LAB ON A CHIP 2025. [PMID: 39878525 PMCID: PMC11776456 DOI: 10.1039/d4lc00927d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Accepted: 01/16/2025] [Indexed: 01/31/2025]
Abstract
Wearable microfluidic sweat sensors could play a major role in the future of monitoring health and wellbeing. Sweat contains biomarkers to monitor health and hydration status, and it can provide information on drug intake, making it an interesting non-invasive alternative to blood. However, sweat is not created in excess, and this requires smart sweat collection strategies to handle small volumes. Microfluidic solutions are commonly employed which use capillary action or evaporation to drive flow. In current literature about sweat analytics, the emphasis lies predominantly on developing the sensors for measuring the composition of sweat. Yet, solely measuring sweat composition does not suffice, because the composition varies due to inter- and intra-individual differences in sweat rate. The measurement of sweat rate is thus crucial for enabling a reliable interpretation and standardisation of this data. Recently, more wearable sweat sensors, also integrating a means of measuring flow, have been developed. This manuscript reviews state-of-the-art sweat collection strategies and flow rate measuring techniques. Generally, flow rate measurements are performed by impedimetric or capacitive methods. However, these techniques can be impaired due to limited lifetime and signal interference from changing ionic contents in sweat. Discrete measurement techniques, such as impedance measurements of an advancing fluid front with interdigitated electrodes, calorimetric and colorimetric techniques can be very reliable, because they selectively measure flow. However, one should take the available size, intended application and compatibility with other sensors into account. Overall, accurate flow rate sensors integrated in reliable microfluidic sweat sensor platforms will enable the standardisation of sweat measurements to unlock the potential of sweat analytics in advancing physiological research, personalized diagnostics and treatment of diseases.
Collapse
Affiliation(s)
- R F R Ursem
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - A Steijlen
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - M Parrilla
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - J Bastemeijer
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - A Bossche
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - K De Wael
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| |
Collapse
|
2
|
Colachis M, Schlink BR, Colachis S, Shqau K, Huegen BL, Palmer K, Heintz A. Benchtop Performance of Novel Mixed Ionic-Electronic Conductive Electrode Form Factors for Biopotential Recordings. SENSORS (BASEL, SWITZERLAND) 2024; 24:3136. [PMID: 38793990 PMCID: PMC11125343 DOI: 10.3390/s24103136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 05/02/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024]
Abstract
Background: Traditional gel-based (wet) electrodes for biopotential recordings have several shortcomings that limit their practicality for real-world measurements. Dry electrodes may improve usability, but they often suffer from reduced signal quality. We sought to evaluate the biopotential recording properties of a novel mixed ionic-electronic conductive (MIEC) material for improved performance. Methods: We fabricated four MIEC electrode form factors and compared their signal recording properties to two control electrodes, which are electrodes commonly used for biopotential recordings (Ag-AgCl and stainless steel). We used an agar synthetic skin to characterize the impedance of each electrode form factor. An electrical phantom setup allowed us to compare the recording quality of simulated biopotentials with ground-truth sources. Results: All MIEC electrode form factors yielded impedances in a similar range to the control electrodes (all <80 kΩ at 100 Hz). Three of the four MIEC samples produced similar signal-to-noise ratios and interfacial charge transfers as the control electrodes. Conclusions: The MIEC electrodes demonstrated similar and, in some cases, better signal recording characteristics than current state-of-the-art electrodes. MIEC electrodes can also be fabricated into a myriad of form factors, underscoring the great potential this novel material has across a wide range of biopotential recording applications.
Collapse
Affiliation(s)
- Matthew Colachis
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Bryan R. Schlink
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Sam Colachis
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Krenar Shqau
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Brittani L. Huegen
- UES, a BlueHalo Company, 4401 Dayton Xenia Road, Beavercreek, OH 45432, USA;
| | - Katherine Palmer
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Amy Heintz
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| |
Collapse
|
3
|
Menke MA, Li BM, Arnold MG, Mueller LE, Dietrich R, Zhou S, Kelley‐Loughnane N, Dennis P, Boock JT, Estevez J, Tabor CE, Sparks JL. Silky Liquid Metal Electrodes for On-Skin Health Monitoring. Adv Healthc Mater 2024; 13:e2301811. [PMID: 37779336 PMCID: PMC11468510 DOI: 10.1002/adhm.202301811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 09/15/2023] [Indexed: 10/03/2023]
Abstract
Next generation on-skin electrodes will require soft, flexible, and gentle materials to provide both high-fidelity sensing and wearer comfort. However, many commercially available on-skin electrodes lack these key properties due to their use of rigid hardware, harsh adhesives, uncomfortable support structures, and poor breathability. To address these challenges, this work presents a new device paradigm by joining biocompatible electrospun spider silk with printable liquid metal to yield an incredibly soft and scalable on-skin electrode that is strain-tolerant, conformable, and gentle on-skin. These electrodes, termed silky liquid metal (SLiM) electrodes, are found to be over five times more breathable than commercial wet electrodes, while the silk's intrinsic adhesion mechanism allows SLiM electrodes to avoid the use of harsh artificial adhesives, potentially decreasing skin irritation and inflammation over long-term use. Finally, the SLiM electrodes provide comparable impedances to traditional wet and other liquid metal electrodes, offering a high-fidelity sensing alternative with increased wearer comfort. Human subject testing confirmed the SLiM electrodes ability to sense electrophysiological signals with high fidelity and minimal irritation to the skin. The unique properties of the reported SLiM electrodes offer a comfortable electrophysiological sensing solution especially for patients with pre-existing skin conditions or surface wounds.
Collapse
Affiliation(s)
- Maria A. Menke
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Braden M. Li
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
- Air Force Life Cycle Management CenterHuman Systems DivisionWright‐Patterson AFBDaytonOH45433USA
| | - Meghan G. Arnold
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Logan E. Mueller
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Robin Dietrich
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Shijie Zhou
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Nancy Kelley‐Loughnane
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Patrick Dennis
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Jason T. Boock
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Joseph Estevez
- Naval Air Warfare CenterWeapons DivisionChina LakeCA93555USA
| | - Christopher E. Tabor
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Jessica L. Sparks
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| |
Collapse
|
4
|
Sivakumar A, Sharma R, Thota C, Ding D, Fan X. WASP: Wearable Analytical Skin Probe for Dynamic Monitoring of Transepidermal Water Loss. ACS Sens 2023; 8:4407-4416. [PMID: 37953512 PMCID: PMC10683758 DOI: 10.1021/acssensors.3c01936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/22/2023] [Accepted: 10/31/2023] [Indexed: 11/14/2023]
Abstract
Early diagnosis of skin barrier dysfunction helps provide timely preventive care against diseases such as atopic dermatitis, psoriasis, food allergies, and other atopic skin disorders. Skin barrier function is commonly evaluated by measuring the transepidermal water loss (TEWL) through stratum corneum due to its noninvasive characteristics. However, existing commercial TEWL devices are significantly affected by many factors, such as ambient temperature, humidity, air flow, water accumulation, initial water contents on the skin surface, bulky sizes, high costs, and requirements for well-controlled environments. Here, we developed a wearable closed-chamber hygrometer-based TEWL device (Wearable Analytical Skin Probe, WASP) and the related algorithm for accurate and continuous monitoring of skin water vapor flux. The WASP uses short dry air purges to dry the skin surface and chamber before each water vapor flux measurement. Its design ensures a highly controlled local environment, such as consistent initial dry conditions for the skin surface and the chamber. We further applied WASP to measure the water vapor flux from six different locations of a small group of human participants. It is found that the WASP can not only measure and distinguish between insensible sweating (i.e., TEWL) and sensible sweating (i.e., thermal sweating) but also track skin dehydration-rehydration cycles. Comparisons with a commercial TEWL device, AquaFlux, show that the results obtained by both devices agree well. The WASP will be broadly applicable to clinical, cosmetic, and biomedical research.
Collapse
Affiliation(s)
- Anjali
Devi Sivakumar
- Department
of Biomedical Engineering, University of
Michigan, Ann Arbor, Michigan 48109, United States
- Department
of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, United States
- Center
for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, Michigan 48109, United States
- Max
Harry Weil Institute for Critical Care Research and Innovation, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Ruchi Sharma
- Department
of Biomedical Engineering, University of
Michigan, Ann Arbor, Michigan 48109, United States
- Center
for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, Michigan 48109, United States
- Max
Harry Weil Institute for Critical Care Research and Innovation, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Chandrakalavathi Thota
- Department
of Biomedical Engineering, University of
Michigan, Ann Arbor, Michigan 48109, United States
- Center
for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, Michigan 48109, United States
- Max
Harry Weil Institute for Critical Care Research and Innovation, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Ding Ding
- Department
of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Xudong Fan
- Department
of Biomedical Engineering, University of
Michigan, Ann Arbor, Michigan 48109, United States
- Center
for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, Michigan 48109, United States
- Max
Harry Weil Institute for Critical Care Research and Innovation, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
5
|
Liu Y, Li X, Yang H, Zhang P, Wang P, Sun Y, Yang F, Liu W, Li Y, Tian Y, Qian S, Chen S, Cheng H, Wang X. Skin-Interfaced Superhydrophobic Insensible Sweat Sensors for Evaluating Body Thermoregulation and Skin Barrier Functions. ACS NANO 2023; 17:5588-5599. [PMID: 36745638 DOI: 10.1021/acsnano.2c11267] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Monitoring sweat rate is vital for estimating sweat loss and accurately measuring biomarkers of interest. Although various optical or electrical sensors have been developed to monitor the sensible sweat rate, the quantification of the insensible sweat rate that is directly related to body thermoregulation and skin barrier functions still remains a challenge. This work introduces a superhydrophobic sweat sensor based on a polyacrylate sodium/MXene composite sandwiched between two superhydrophobic textile layers to continuously measure sweat vapor from insensible sweat with high sensitivity and rapid response. The superhydrophobic textile on a holey thin substrate with reduced stiffness and excellent breathability allows the permeation of sweat vapor, while preventing the sensor from being affected by the external water droplets and internal sensible sweat. Integrating the insensible sweat sensor with a flexible wireless communication and powering module further yields a standalone sensing system to continuously monitor insensible sweat rates at different body locations for diverse application scenarios. Proof-of-concept demonstrations on human subjects showcase the feasibility to continuously evaluate the body's thermoregulation and skin barrier functions for the assessment of thermal comfort, disease conditions, and nervous system activity. The results presented in this work also provide a low-cost device platform to detect other health-relevant biomarkers in the sweat (vapor) as the next-generation sweat sensor for smart healthcare and personalized medicine.
Collapse
Affiliation(s)
- Yangchengyi Liu
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Xiaofeng Li
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Hanlin Yang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Ping Zhang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Peihe Wang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Yi Sun
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Fengzhen Yang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Weiyi Liu
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Yujing Li
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Yao Tian
- School of Chemistry, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Shun Qian
- School of Chemistry, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Shangda Chen
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Xiufeng Wang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| |
Collapse
|
6
|
Liu L, Zhang X. A Focused Review on the Flexible Wearable Sensors for Sports: From Kinematics to Physiologies. MICROMACHINES 2022; 13:1356. [PMID: 36014277 PMCID: PMC9412724 DOI: 10.3390/mi13081356] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 08/15/2022] [Accepted: 08/16/2022] [Indexed: 05/15/2023]
Abstract
As an important branch of wearable electronics, highly flexible and wearable sensors are gaining huge attention due to their emerging applications. In recent years, the participation of wearable devices in sports has revolutionized the way to capture the kinematical and physiological status of athletes. This review focuses on the rapid development of flexible and wearable sensor technologies for sports. We identify and discuss the indicators that reveal the performance and physical condition of players. The kinematical indicators are mentioned according to the relevant body parts, and the physiological indicators are classified into vital signs and metabolisms. Additionally, the available wearable devices and their significant applications in monitoring these kinematical and physiological parameters are described with emphasis. The potential challenges and prospects for the future developments of wearable sensors in sports are discussed comprehensively. This review paper will assist both athletic individuals and researchers to have a comprehensive glimpse of the wearable techniques applied in different sports.
Collapse
Affiliation(s)
- Lei Liu
- Department of Sports, Xi'an Polytechnic University, Xi'an 710048, China
| | - Xuefeng Zhang
- Shaanxi Key Laboratory of Nano Materials and Technology, Xi'an University of Architecture and Technology, Xi'an 710055, China
- School of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| |
Collapse
|
7
|
Deep Learning-Based Football Player Detection in Videos. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:3540642. [PMID: 35865491 PMCID: PMC9296282 DOI: 10.1155/2022/3540642] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 06/28/2022] [Indexed: 11/21/2022]
Abstract
The main task of football video analysis is to detect and track players. In this work, we propose a deep convolutional neural network-based football video analysis algorithm. This algorithm aims to detect the football player in real time. First, five convolution blocks were used to extract a feature map of football players with different spatial resolution. Then, features from different levels are combined together with weighted parameters to improve detection accuracy and adapt the model to input images with various resolutions and qualities. Moreover, this algorithm can be extended to a framework for detecting players in any other sports. The experimental results assure the effectiveness of our algorithm.
Collapse
|
8
|
Wang H, Xu K, Xu H, Huang A, Fang Z, Zhang Y, Wang Z, Lu K, Wan F, Bai Z, Wang Q, Zhang L, Wu L. A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate. MICROMACHINES 2022; 13:414. [PMID: 35334706 PMCID: PMC8950908 DOI: 10.3390/mi13030414] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/03/2022] [Accepted: 03/04/2022] [Indexed: 12/19/2022]
Abstract
Collecting sweat and monitoring its rate is important for determining body condition and further sweat analyses, as this provides vital information about physiologic status and fitness level and could become an alternative to invasive blood tests in the future. Presented here is a one-dollar, disposable, paper-based microfluidic chip for real-time monitoring of sweat rate. The chip, pasted on any part of the skin surface, consists of a skin adhesive layer, sweat-proof layer, sweat-sensing layer, and scale layer with a disk-shape from bottom to top. The sweat-sensing layer has an impressed wax micro-channel containing pre-added chromogenic agent to show displacement by sweat, and the sweat volume can be read directly by scale lines without any electronic elements. The diameter and thickness of the complete chip are 25 mm and 0.3 mm, respectively, permitting good flexibility and compactness with the skin surface. Tests of sweat flow rate monitoring on the left forearm, forehead, and nape of the neck of volunteers doing running exercise were conducted. Average sweat rate on left forearm (1156 g·m-2·h-1) was much lower than that on the forehead (1710 g·m-2·h-1) and greater than that on the nape of the neck (998 g·m-2·h-1), in good agreement with rates measured using existing common commercial sweat collectors. The chip, as a very low-cost and convenient wearable device, has wide application prospects in real-time monitoring of sweat loss by body builders, athletes, firefighters, etc., or for further sweat analyses.
Collapse
Affiliation(s)
- Hongcheng Wang
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Kai Xu
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Haihao Xu
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Along Huang
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Zecong Fang
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China;
- Shenzhen Engineering Laboratory of Single-Molecule Detection and Instrument Development, Shenzhen 518055, China
| | - Yifan Zhang
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Ze’en Wang
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Kai Lu
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Fei Wan
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Zihao Bai
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Qiao Wang
- School of Pharmacy, Hangzhou Medical College, Hangzhou 310059, China;
| | - Linan Zhang
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| | - Liqun Wu
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (K.X.); (H.X.); (A.H.); (Y.Z.); (Z.W.); (K.L.); (F.W.); (Z.B.); (L.Z.); (L.W.)
| |
Collapse
|
9
|
Zhong B, Jiang K, Wang L, Shen G. Wearable Sweat Loss Measuring Devices: From the Role of Sweat Loss to Advanced Mechanisms and Designs. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103257. [PMID: 34713981 PMCID: PMC8728835 DOI: 10.1002/advs.202103257] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/15/2021] [Indexed: 05/22/2023]
Abstract
Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and psychological states. However, measured biomarker concentrations vary with sweat rates, which has a significant effect on the accuracy and reliability of sweat biosensors. Wearable sweat loss measuring devices (SLMDs) have recently been proposed to overcome the limitations of biomarker tracking and reduce inter- and intraindividual variability. In addition, they offer substantial potential for monitoring human body homeostasis, because sweat loss plays an indispensable role in thermoregulation and skin hydration. Previous studies have not carried out a comprehensive and systematic review of the principles, importance, and development of wearable SLMDs. This paper reviews wearable SLMDs with a new health perspective from the role of sweat loss to advanced mechanisms and designs. Two types of sweat and their measurement significance for practical applications are highlighted. Then, a comprehensive review of advances in different wearable SLMDs based on hygrometers, absorbent materials, and microfluidics is presented by describing their respective device architectures, present situations, and future directions. Finally, concluding remarks on opportunities for future application fields and challenges for future sweat sensing are presented.
Collapse
Affiliation(s)
- Bowen Zhong
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Kai Jiang
- Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Institute of Hepatobiliary Surgery of Chinese PLA, Key Laboratory of Digital Hepatobiliary Surgery, Chinese PLA, Beijing, 100853, China
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Guozhen Shen
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| |
Collapse
|
10
|
Yokus BMA, Daniele MA. Integrated non-invasive biochemical and biophysical sensing systems for health and performance monitoring: A systems perspective. Biosens Bioelectron 2021; 184:113249. [PMID: 33895689 DOI: 10.1016/j.bios.2021.113249] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 04/09/2021] [Accepted: 04/12/2021] [Indexed: 12/21/2022]
Abstract
Advances in materials, bio-recognition elements, transducers, and microfabrication techniques, as well as progress in electronics, signal processing, and wireless communication have generated a new class of skin-interfaced wearable health monitoring systems for applications in personalized medicine and digital health. In comparison to conventional medical devices, these wearable systems are at the cusp of initiating a new era of longitudinal and noninvasive sensing for the prevention, detection, diagnosis, and treatment of diseases at the molecular level. Herein, we provide a review of recent developments in wearable biochemical and biophysical systems. We survey the sweat sampling and collection methods for biochemical systems, followed by an assessment of biochemical and biophysical sensors deployed in current wearable systems with an emphasis on their hardware specifications. Specifically, we address how sweat collection and sample handling platforms may be a rate limiting technology to realizing the clinical translation of wearable health monitoring systems; moreover, we highlight the importance of achieving both longitudinal sensing and assessment of intrapersonal variation in sweat-blood correlations to have the greatest clinical impact. Lastly, we assess a snapshot of integrated wireless wearable systems with multimodal sensing capabilities, and we conclude with our perspective on the state-of-the-art and the required developments to achieve the next-generation of integrated wearable health and performance monitoring systems.
Collapse
Affiliation(s)
- By Murat A Yokus
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA
| | - Michael A Daniele
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA; Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, 911 Oval Dr., Raleigh, NC, 27695, USA.
| |
Collapse
|
11
|
Valarezo Añazco E, Han SJ, Kim K, Lopez PR, Kim TS, Lee S. Hand Gesture Recognition Using Single Patchable Six-Axis Inertial Measurement Unit via Recurrent Neural Networks. SENSORS (BASEL, SWITZERLAND) 2021; 21:1404. [PMID: 33671364 PMCID: PMC7922880 DOI: 10.3390/s21041404] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 02/09/2021] [Accepted: 02/09/2021] [Indexed: 12/14/2022]
Abstract
Recording human gestures from a wearable sensor produces valuable information to implement control gestures or in healthcare services. The wearable sensor is required to be small and easily worn. Advances in miniaturized sensor and materials research produces patchable inertial measurement units (IMUs). In this paper, a hand gesture recognition system using a single patchable six-axis IMU attached at the wrist via recurrent neural networks (RNN) is presented. The IMU comprises IC-based electronic components on a stretchable, adhesive substrate with serpentine-structured interconnections. The proposed patchable IMU with soft form-factors can be worn in close contact with the human body, comfortably adapting to skin deformations. Thus, signal distortion (i.e., motion artifacts) produced for vibration during the motion is minimized. Also, our patchable IMU has a wireless communication (i.e., Bluetooth) module to continuously send the sensed signals to any processing device. Our hand gesture recognition system was evaluated, attaching the proposed patchable six-axis IMU on the right wrist of five people to recognize three hand gestures using two models based on recurrent neural nets. The RNN-based models are trained and validated using a public database. The preliminary results show that our proposed patchable IMU have potential to continuously monitor people's motions in remote settings for applications in mobile health, human-computer interaction, and control gestures recognition.
Collapse
Affiliation(s)
- Edwin Valarezo Añazco
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
- Faculty of Engineering in Electricity and Computation, FIEC, Escuela Superior Politécnica del Litoral, ESPOL, Guayaquil EC090112, Ecuador
| | - Seung Ju Han
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
| | - Kangil Kim
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
| | - Patricio Rivera Lopez
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
| | - Tae-Seong Kim
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
| | - Sangmin Lee
- Department of Information Convergence Engineering, Kyung Hee University, Yongin 17104, Korea; (E.V.A.); (S.J.H.); (K.K.); (P.R.L.); (T.-S.K.)
| |
Collapse
|
12
|
Choi DH, Gonzales M, Kitchen GB, Phan DT, Searson PC. A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss. ACS Sens 2020; 5:3821-3826. [PMID: 33263987 DOI: 10.1021/acssensors.0c01219] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Individualized measurement of sweat loss under heat stress is important in assessing physical performance and preventing heat-related illness for athletes or individuals working in extreme environments. The objective of this work was to develop a low-cost and easy-to-fabricate wearable sensor that enables accurate real-time measurement of sweat rate. A capacitive-type sensor was fabricated from two conducting parallel plates, plastic insulating layers, and a central microfluidic channel formed by laser cutting a plastic film. The device has no microfabricated electrodes and is assembled using adhesive tape. Sensor accuracy was validated at different flow rates and confirmed using an equivalent circuit model of the device. On-body measurements demonstrate the feasibility of real-time measurements and show good agreement with values determined from a conventional sweat collection device.
Collapse
Affiliation(s)
- Dong-Hoon Choi
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Mark Gonzales
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Grant B. Kitchen
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Dinh-Tuan Phan
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| | - Peter C. Searson
- Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
- Department of Materials Science and Engineering, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
| |
Collapse
|
13
|
Ohashi T, Gerrett N, Shinkawa S, Sato T, Miyake R, Kondo N, Mitsuzawa S. Fluidic Patch Device to Sample Sweat for Accurate Measurement of Sweat Rate and Chemical Composition: A Proof-of-Concept Study. Anal Chem 2020; 92:15534-15541. [PMID: 33169984 DOI: 10.1021/acs.analchem.0c03466] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Sweat sensors that can continuously sample sweat are critical for determining the time-dependent physiological responses occurring in normal daily life. Here, a new device, termed fluidic patch, for collecting human sweat samples at defined time intervals is developed, and the proof-of-concept is demonstrated. The device comprises micropumps and a disposable microfluidic patch attached to the human skin. The fluidic patch continuously collects aliquots of freshly secreted sweat accumulated in the fluidic pathway at accurately defined time windows (typically 5 min). By measuring the weight of the collected samples, the local sweat rate is calculated. The sweat sample collected can be directly subjected to a wide range of chemical analyses. For the proof-of-concept, we compared the sweat rates during passive heating in human trials using the fluidic patch and the conventional ventilated sweat capsule system. Although the sweat rate obtained using the fluidic patch highly correlated with that of the ventilated sweat capsule (R2 = 0.96, y = 1.4x - 0.05), the fluidic patch overestimated the sweat rate compared with the ventilated capsule system when the sweat rate exceeded 0.5 mg/(cm2·min). The sampled sweat was analyzed for sodium, potassium, chloride, lactate, pyruvate, and cortisol. The device could obtain the time courses of the concentrations of the abovementioned three ions; the concentrations of sodium and chloride increased linearly with the sweat rate during passive heating (R2 = 0.76 and 0.66, respectively). The device can reliably measure the sweat rate and collect sweat samples for chemical analysis. It can be utilized for real-time physiological investigations toward wider applications.
Collapse
Affiliation(s)
- Tomoaki Ohashi
- Honda Research Institute Japan Co., Ltd., 8-1 Honcho, Wako 351-0188, Japan
| | - Nicola Gerrett
- Laboratory for Applied Human Physiology, Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada-ku, Kobe 657-8501, Japan.,Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Van der Boechorststraat 7-9, 1081 BT Amsterdam, The Netherlands
| | - Satoru Shinkawa
- Honda Research Institute Japan Co., Ltd., 8-1 Honcho, Wako 351-0188, Japan
| | - Tomomi Sato
- Microfluidic Integrated Circuits Research Laboratory, Graduate School of Engineering, The University of Tokyo, 7-7 Shinkawasaki, Saiwai-ku, Kawasaki 212-0032, Japan
| | - Ryo Miyake
- Microfluidic Integrated Circuits Research Laboratory, Graduate School of Engineering, The University of Tokyo, 7-7 Shinkawasaki, Saiwai-ku, Kawasaki 212-0032, Japan
| | - Narihiko Kondo
- Laboratory for Applied Human Physiology, Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada-ku, Kobe 657-8501, Japan
| | | |
Collapse
|
14
|
Yokus MA, Agcayazi T, Traenkle M, Bozkurt A, Daniele MA. Wearable Sweat Rate Sensors. 2020 IEEE SENSORS 2020. [DOI: 10.1109/sensors47125.2020.9278818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
15
|
van Staden D, du Plessis J, Viljoen J. Development of a Self-Emulsifying Drug Delivery System for Optimized Topical Delivery of Clofazimine. Pharmaceutics 2020; 12:E523. [PMID: 32521671 PMCID: PMC7356627 DOI: 10.3390/pharmaceutics12060523] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/27/2020] [Accepted: 06/02/2020] [Indexed: 11/24/2022] Open
Abstract
A quality-by-design and characterization approach was followed to ensure development of self-emulsifying drug delivery systems (SEDDSs) destined for topical delivery of the highly lipophilic clofazimine. Solubility and water-titration experiments identified spontaneous emulsification capacity of different excipient combinations and clofazimine. After identifying self-emulsification regions, check-point formulations were selected within the self-emulsification region by considering characteristics required to achieve optimized topical drug delivery. Check-point formulations, able to withstand phase separation after 24 h at an ambient temperature, were subjected to characterization studies. Experiments involved droplet size evaluation; size distribution; zeta-potential; self-emulsification time and efficacy; viscosity and pH measurement; cloud point assessment; and thermodynamic stability studies. SEDDSs with favorable properties, i.e., topical drug delivery, were subjected to dermal diffusion studies. Successful in vitro topical clofazimine delivery was observed. Olive oil facilitated the highest topical delivery of clofazimine probably due to increased oleic acid levels that enhanced stratum corneum lipid disruption, followed by improved dermal clofazimine delivery. Finally, isothermal microcalometric experiments studied the compatibility of excipients. Potential interactions were depicted between argan oil and clofazimine as well as between Span®60 and argan-, macadamia- and olive oil, respectively. However, despite some mundane incompatibilities, successful development of topical SEDDSs achieved enhanced topical clofazimine delivery.
Collapse
Affiliation(s)
| | | | - Joe Viljoen
- Faculty of Health Sciences, Centre of Excellence for Pharmaceutical Sciences (PharmacenTM), Building G16, North-West University, 11 Hoffman Street, Potchefstroom, North-West Province 2520, South Africa; (D.v.S.); (J.d.P.)
| |
Collapse
|
16
|
Carr AR, Patel YH, Neff CR, Charkhabi S, Kallmyer NE, Angus HF, Reuel NF. Sweat monitoring beneath garments using passive, wireless resonant sensors interfaced with laser-ablated microfluidics. NPJ Digit Med 2020; 3:62. [PMID: 32377573 PMCID: PMC7193562 DOI: 10.1038/s41746-020-0270-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 03/20/2020] [Indexed: 11/09/2022] Open
Abstract
Sweat loss can help determine hydration status of individuals working in harsh conditions, which is especially relevant to those who wear thick personal protective equipment (PPE) such as firefighters. A wireless, passive, conformable sweat sensor sticker is described here that can be worn under and interrogated through thick clothing to simultaneously measure sweat loss volume and conductivity. The sticker consists of a laser-ablated, microfluidic channel and a resonant sensor transducer. The resonant sensor is wirelessly read with a handheld vector network analyzer coupled to two, co-planar, interrogation antennas that measure the transmission loss. A sweat proxy is used to fill the channels and it is determined that the sensor can orthogonally determine the sweat conductivity and volume filled in the channel via peak transmission loss magnitude and frequency respectively. A four-person study is then used to determine level of sensor variance caused by local tissue dielectric heterogeneity and sensor-reader orientation.
Collapse
Affiliation(s)
- Adam R. Carr
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| | - Yash H. Patel
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| | - Charles R. Neff
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| | - Sadaf Charkhabi
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| | - Nathaniel E. Kallmyer
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| | - Hector F. Angus
- Department of Kinesiology, Iowa State University, Ames, IA USA
| | - Nigel F. Reuel
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA USA
| |
Collapse
|
17
|
Real-Time Humidity Measurement during Sports Activity using Optical Fibre Sensing. SENSORS 2020; 20:s20071904. [PMID: 32235429 PMCID: PMC7181039 DOI: 10.3390/s20071904] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 03/26/2020] [Accepted: 03/28/2020] [Indexed: 11/16/2022]
Abstract
An optical fibre sensor for monitoring relative humidity (RH) changes during exercise is demonstrated. The humidity sensor comprises a tip coating of poly (allylamine hydrochloride) (PAH)/silica nanoparticles (SiO2 NPs) deposited using the layer-by-layer technique. An uncoated fibre is employed to compensate for bending losses that are likely to occur during movement. A linear fit to the response of the sensing system to RH demonstrates a sensitivity of 3.02 mV/% (R2 = 0.96), hysteresis ± 1.17% RH when 11 bilayers of PAH/SiO2 NPs are coated on the tip of the fibre. The performance of two different textiles (100% cotton and 100% polyester) were tested in real-time relative humidity measurement for 10 healthy volunteers. The results demonstrate the moisture wicking properties of polyester in that the relative humidity dropped more rapidly after cessation of exercise compared to cotton. The approach has the potential to be used to monitor sports performance and by clothing developers for characterising different garment designs.
Collapse
|
18
|
Wireless Epidermal Six-Axis Inertial Measurement Units for Real-Time Joint Angle Estimation. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10072240] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Technological advances in wireless communications, miniaturized sensors, and low-power electronics have made it possible to implement integrated wireless body area networks (WBANs). These developments enable the applications of wireless wearable systems for diagnosis, health monitoring, rehabilitation, and dependency care. Across the current range of commercial wearable devices, the products are not firmly fixed to the human body. To minimize data error caused by movement of the human body and to achieve accurate measurements, it is essential to bring the wearable device close to the skin. This paper presents the implementation of a patch-type, six-axis inertial measurement unit (IMU) with wireless communication technology. The device comprises hard-electronic components on a stretchable elastic substrate for application in epidermal electronics, to collect precise data from the human body. Instead of the commonly used cleanroom processes of implementing devices on a stretchable substrate, a simple and inexpensive “cut-solder-paste” method is adopted to fabricate complex, convoluted interconnections. Thus, the signal distortions in the proposed device can be minimized during various physical activities and skin deformations when used in gait analysis. The inertial sensor data measured from the motion of the body can be sent in real-time via Bluetooth to any processing unit enabled with such a widespread standard wireless interface. For performance evaluation, the implemented device is mounted on a rotation plate in order to compare performance with the conventional product. In addition, an experiment on joint angle estimation is performed by attaching the device to an actual human body. The preliminary results of the device indicate the potential to monitor people in remote settings for applications in mobile health, human-computer interfaces (HCIs), and wearable robots.
Collapse
|
19
|
Dockray S, O'Neill S, Jump O. Measuring the Psychobiological Correlates of Daily Experience in Adolescents. JOURNAL OF RESEARCH ON ADOLESCENCE : THE OFFICIAL JOURNAL OF THE SOCIETY FOR RESEARCH ON ADOLESCENCE 2019; 29:595-612. [PMID: 31573767 DOI: 10.1111/jora.12473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Mapping the psychobiological correlates of social contexts, experiences, and emotional responses of adolescents in their daily lives provides insight into how adolescent well-being shapes, and is shaped by, experience. Measures of these psychobiological correlates are enabled by devices and technologies that must be precise and suitable for adolescent participants. The present report reviews the most often used research measures, and suggests strategies for best practice, drawn from practical experience. The rapid advances in technological methods to collect attuned measures of psychological processes, social context, and biological function indicate the promise for multimodal measures in ecological settings. Attaining these methodological goals will support research to secure comprehensive, quality data, and advance the understanding of psychobiological function in ambulatory settings.
Collapse
|
20
|
Lopes PA, Vaz Gomes D, Green Marques D, Faia P, Góis J, Patrício TF, Coelho J, Serra A, de Almeida AT, Majidi C, Tavakoli M. Soft Bioelectronic Stickers: Selection and Evaluation of Skin-Interfacing Electrodes. Adv Healthc Mater 2019; 8:e1900234. [PMID: 31273945 DOI: 10.1002/adhm.201900234] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 05/16/2019] [Indexed: 12/14/2022]
Abstract
Surface biopotentials collected from the human epidermis contain important information about human physiology, such as muscular, heart, and brain activities. However, commercially available wearable biomonitoring devices are generally composed of rigid hardware incompatible with the mechanical compliance of soft human tissues. Thin-film stretchable e-skin circuits that can interface the human skin represent an excellent alternative for long-term wearable biomonitoring. Here, a series of soft and stretchable electrodes are evaluated for their applicability in biopotential sensing. This includes conductive composites made of polydimethylsiloxane (PDMS) as a base substrate and conductive particles, i.e., carbon (cPDMS), silver (AgPDMS), anisotropic z-axis conductors made with silver-coated nickel particles (zPDMS), as well as a combination of a conductive tough hydrogel with PDMS, and finally ultrathin tattoo-like adhesive poly(vinyl alcohol)-coated films with stretchable biphasic Ag-EGaIn electrodes. These electrodes are compared between themselves and against the gold-standard Ag/AgCl and stainless steel electrodes, in order to assess relative performance in signal-to-noise ratio (SNR) during electrocardiography, and electrode-skin impedance for a range of frequencies. Results show a direct relation between conformity of the electrode-skin interface and the SNR value. An all-integrated biomonitoring patch with embedded processing and communication electronics, hydrogel electrodes, and a multilayer liquid metal circuit is presented for electromyography.
Collapse
Affiliation(s)
- Pedro Alhais Lopes
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Davide Vaz Gomes
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Daniel Green Marques
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Pedro Faia
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Joana Góis
- CEMMPRE – Department of Chemical EngineeringUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Tatiana F. Patrício
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Jorge Coelho
- CEMMPRE – Department of Chemical EngineeringUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Arménio Serra
- CEMMPRE – Department of Chemical EngineeringUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Aníbal T. de Almeida
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| | - Carmel Majidi
- Integrated Soft Materials LabDepartment of Mechanical EngineeringCarnegie Mellon University Pittsburgh PA 15213 USA
| | - Mahmoud Tavakoli
- Soft and Printed Microelectronics LabInstitute of Systems and RoboticsUniversity of Coimbra Coimbra 3030‐290 Portugal
| |
Collapse
|
21
|
Gil B, Anastasova S, Yang GZ. A Smart Wireless Ear-Worn Device for Cardiovascular and Sweat Parameter Monitoring During Physical Exercise: Design and Performance Results. SENSORS 2019; 19:s19071616. [PMID: 30987280 PMCID: PMC6480663 DOI: 10.3390/s19071616] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 03/25/2019] [Accepted: 03/30/2019] [Indexed: 11/27/2022]
Abstract
Wearable biomedical technology has gained much support lately as devices have become more affordable to the general public and they can easily interact with mobile phones and other platforms. The feasibility and accuracy of the data generated by these devices so as to replace the standard medical methods in use today is still under scrutiny. In this paper, we present an ear-worn device to measure cardiovascular and sweat parameters during physical exercise. ECG bipolar recordings capture the electric potential around both ears, whereas sweat rate is estimated by the impedance method over one segment of tissue closer to the left ear, complemented by the measurement of the lactate and pH levels using amperiometric and potentiometric sensors, respectively. Together with head acceleration, the acquired data is sent to a mobile phone via BLE, enabling extended periods of signal recording. Results obtained by the device have shown a SNR level of 18 dB for the ECG signal recorded around the ears, a THD value of −20.46 dB for the excitation signal involved in impedance measurements, sweat conductivity of 0.08 S/m at 1 kHz and sensitivities of 50 mV/pH and 0.8 μA/mM for the pH and lactate acquisition channels, respectively. Testing of the device was performed in human subjects during indoors cycling with characteristic level changes.
Collapse
Affiliation(s)
- Bruno Gil
- The Hamlyn Centre, Imperial College London, London SW7 2AZ, UK.
| | | | - Guang Z Yang
- The Hamlyn Centre, Imperial College London, London SW7 2AZ, UK.
| |
Collapse
|
22
|
Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring. Sci Rep 2018; 8:1181. [PMID: 29352237 PMCID: PMC5775419 DOI: 10.1038/s41598-018-19239-8] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Accepted: 12/14/2017] [Indexed: 12/02/2022] Open
Abstract
We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m2h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m2h in thermal statuses including ‘comfortable’, ‘slightly warm’, ‘warm’, and ‘hot’. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.
Collapse
|