1
|
Feng W, Liu Y, Gao L. Stormwater treatment for reuse: Current practice and future development - A review. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 301:113830. [PMID: 34600425 DOI: 10.1016/j.jenvman.2021.113830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 08/18/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
Stormwater harvesting is an effective measure to mitigate flooding risk and pollutant migration in our urban environment with the continuously increasing impermeable faction. Treatment of harvested stormwater also provides the fit-for-purpose water sources as an alternative to potable water supply ensuring the reliability and sustainability of the water management in the living complex. In order to provide the water management decision-maker with a broad range of related technology database and to facilitate the implementation of stormwater harvesting in the future, a comprehensive review was undertaken to understand the corresponding treatment performance, the applicable circumstances of current stormwater treatment and harvesting technologies. Technologies with promising potential for stormwater treatment were also reviewed to investigate the feasibility of being used in an integrated process. The raw stormwater quality and the required quality for different levels of stormwater reuses (irrigation, recreational, and potable) were reviewed and compared. The required level of treatment is defined for different 'fit-for-purpose' uses of harvested stormwater. Stormwater biofilter and constructed wetland as the two most advanced and widely used stormwater harvesting and treatment technologies, their main functionality, treatment performance and adequate scale of the application were reviewed based on published peer-reviewed articles and case studies. Excessive microbial effluent that exists in stormwater treated using these two technologies has restricted the stormwater reuse in most cases. Water disinfection technologies developed for wastewater and surface water treatment but with high potential to be used for stormwater treatment have been reviewed. Their feasibility and limitation for stormwater treatment are presented with respect to different levels of fit-for-purpose reuses. Implications for future implementation of stormwater treatment are made on proposing treatment trains that are suitable for different fit-for-purpose stormwater reuses.
Collapse
Affiliation(s)
- Wenjun Feng
- Department of Chemical Engineering, Monash University, Clayton, VIC, 3800, Australia
| | - Yue Liu
- Department of Chemical Engineering, Monash University, Clayton, VIC, 3800, Australia
| | - Li Gao
- Institute of Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, Victoria, 8001, Australia; South East Water Corporation, Seaford, VIC, 3198 Australia.
| |
Collapse
|
2
|
Costa EP, Roccamante M, Plaza-Bolaños P, Oller I, Agüera A, Amorim CC, Malato S. Aluminized surface to improve solar light absorption in open reactors: Application for micropollutants removal in effluents from municipal wastewater treatment plants. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 755:142624. [PMID: 33045600 DOI: 10.1016/j.scitotenv.2020.142624] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/28/2020] [Accepted: 09/22/2020] [Indexed: 06/11/2023]
Abstract
This work proposes the evaluation of an aluminized surface on the bottom of open reactors to perform a photo-Fenton process, at circumneutral pH (using Fe III-Ethylenediamine-N,N'-disuccinic acid complex), for elimination of micropollutants (MPs) in real effluents from municipal wastewater treatment plants (EMWWTP). Firstly, the strategy was to initially investigate the real EMWWTP spiked with several MPs (acetaminophen, diclofenac, carbamazepine, caffeine, trimethoprim and sulfamethoxazole) with 20 and 100 μg L-1 in a laboratory scale (evaluated by HPLC-UV) using a solar simulator. Finally, the removal of all MCs present in the real EMWWTP was monitored (evaluated by HPLC-MS) in a pilot-scale (90 L) in a raceway pond reactor (RPR). The treatment time required for degradation above 80% for the investigated MPs was over 30 min, and the predominant effect could be mainly associated with organics present in the real EMWWTP due to the light attenuation and scavenging of radical species. Moreover, the results confirmed that chloride and sulfate would most likely equally not affect the process. The use of an aluminized surface on the bottom of RPRs has been confirmed as a suitable option to improve the photo-Fenton reaction, enabling the use of lower doses of iron. Up to 60 different MPs found in EMWWTP have been successfully degraded using 0.1 mM of Fe at circumneutral pH with a consumption of 30 mg L-1 H2O2 with less than 45 min.
Collapse
Affiliation(s)
- Elizangela P Costa
- Department of Sanitary and Environmental Engineering, Research Group on Environmental Applications of Advanced Oxidation Processes, Universidade Federal de Minas Gerais, Av. Antônio Carlos, 6627, Belo Horizonte, Minas Gerais 31270-901, Brazil
| | - Melina Roccamante
- Solar Energy Research Centre (CIESOL), Joint Centre University of Almería-CIEMAT, Carretera de Sacramento s/n, E-04120 Almería, Spain; Plataforma Solar de Almería, CIEMAT, Carretera Senés Km. 4, E-04200 Tabernas, Almería, Spain
| | - Patricia Plaza-Bolaños
- Solar Energy Research Centre (CIESOL), Joint Centre University of Almería-CIEMAT, Carretera de Sacramento s/n, E-04120 Almería, Spain; Department of Chemistry and Physics, University of Almería, Carretera de Sacramento s/n, E-04120 Almería, Spain
| | - Isabel Oller
- Solar Energy Research Centre (CIESOL), Joint Centre University of Almería-CIEMAT, Carretera de Sacramento s/n, E-04120 Almería, Spain; Plataforma Solar de Almería, CIEMAT, Carretera Senés Km. 4, E-04200 Tabernas, Almería, Spain
| | - Ana Agüera
- Solar Energy Research Centre (CIESOL), Joint Centre University of Almería-CIEMAT, Carretera de Sacramento s/n, E-04120 Almería, Spain; Department of Chemistry and Physics, University of Almería, Carretera de Sacramento s/n, E-04120 Almería, Spain
| | - Camila C Amorim
- Department of Sanitary and Environmental Engineering, Research Group on Environmental Applications of Advanced Oxidation Processes, Universidade Federal de Minas Gerais, Av. Antônio Carlos, 6627, Belo Horizonte, Minas Gerais 31270-901, Brazil
| | - Sixto Malato
- Solar Energy Research Centre (CIESOL), Joint Centre University of Almería-CIEMAT, Carretera de Sacramento s/n, E-04120 Almería, Spain; Plataforma Solar de Almería, CIEMAT, Carretera Senés Km. 4, E-04200 Tabernas, Almería, Spain.
| |
Collapse
|
3
|
Alvear-Daza JJ, García-Barco A, Osorio-Vargas P, Gutiérrez-Zapata HM, Sanabria J, Rengifo-Herrera JA. Resistance and induction of viable but non culturable states (VBNC) during inactivation of E. coli and Klebsiella pneumoniae by addition of H 2O 2 to natural well water under simulated solar irradiation. WATER RESEARCH 2021; 188:116499. [PMID: 33049567 DOI: 10.1016/j.watres.2020.116499] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 10/01/2020] [Accepted: 10/04/2020] [Indexed: 05/15/2023]
Abstract
Inactivation of E. coli and Klebsiella pneumoniae by addition of H2O2 10 mg L-1 into natural well water samples containing natural total iron concentrations (around 0.3 mg L-1) under simulated solar light was followed by bacterial culturability (plate count) and viability (DVC-FISH). Results showed that culturability of both bacteria was totally reduced while viability was only completely depleted for E. coli in well water samples depending of total iron concentration. Post-irradiation effects in presence of residual H2O2 showed that viability of both bacteria kept dropping being totally reduced for E. coli cells while K. pneumoniae decreased only 1-log. SEM micrographs showed that E. coli and K. pneumoniae cells underwent morphological changes and size reduction according to VBNC states. Different dark and photo-induced processes where physical-chemical features of groundwater samples play an important role could be responsible of bacteria abatement.
Collapse
Affiliation(s)
- John J Alvear-Daza
- Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. J.J. Ronco" (CINDECA), Departamento de Química, Facultad de Ciencias Exactas, UNLP-CCT La Plata, CONICET, 47 No. 257, 1900 La Plata, Buenos Aires, Argentina
| | - Alejandra García-Barco
- Grupo de Investigación en Fotocatálisis y Estado Sólido, Escuela de Química, Universidad Técnologica de Pereira, Pereira, Risaralda 660003, Colombia
| | - Paula Osorio-Vargas
- Grupo de Investigación en Fotocatálisis y Estado Sólido, Escuela de Química, Universidad Técnologica de Pereira, Pereira, Risaralda 660003, Colombia; Laboratory of Thermal and Catalytic Processes (LPTC), Chemical Engineering School, Department of Wood Engineering. University of Bío-Bío, Concepción, Chile
| | - Héctor M Gutiérrez-Zapata
- Environmental Microbiology and Biotechnology Laboratory, Engineering School of Environmental & Natural Resources, Engineering Faculty, Universidad del Valle - Sede Meléndez, A.A. 25360, Santiago de Cali-Colombia, Colombia
| | - Janeth Sanabria
- Environmental Microbiology and Biotechnology Laboratory, Engineering School of Environmental & Natural Resources, Engineering Faculty, Universidad del Valle - Sede Meléndez, A.A. 25360, Santiago de Cali-Colombia, Colombia.
| | - Julián A Rengifo-Herrera
- Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. J.J. Ronco" (CINDECA), Departamento de Química, Facultad de Ciencias Exactas, UNLP-CCT La Plata, CONICET, 47 No. 257, 1900 La Plata, Buenos Aires, Argentina.
| |
Collapse
|
4
|
Ozores Diez P, Giannakis S, Rodríguez-Chueca J, Wang D, Quilty B, Devery R, McGuigan K, Pulgarin C. Enhancing solar disinfection (SODIS) with the photo-Fenton or the Fe 2+/peroxymonosulfate-activation process in large-scale plastic bottles leads to toxicologically safe drinking water. WATER RESEARCH 2020; 186:116387. [PMID: 32920335 DOI: 10.1016/j.watres.2020.116387] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/01/2020] [Accepted: 09/02/2020] [Indexed: 06/11/2023]
Abstract
Solar disinfection (SODIS) in 2-L bottles is a well-established drinking water treatment technique, suitable for rural, peri‑urban, or isolated communities in tropical or sub-tropical climates. In this work, we assess the enlargement of the treatment volume by using cheap, large scale plastic vessels. The bactericidal performance of SODIS and two solar-Fe2+ based enhancements, namely photo-Fenton (light/H2O2/Fe2+) and peroxymonosulfate activation (light/PMS/Fe2+) were assessed in 19-L polycarbonate (PC) and 25-L polyethylene terephthalate (PET) bottles, in ultrapure and real water matrices (tap water, lake Geneva water). Although SODIS always reached total (5-logU) inactivation, under solar light, enhancement by or both Fe2+/H2O2 or Fe2+/PMS was always beneficial and led to an increase in bacterial elimination kinetics, as high as 2-fold in PC and PET bottles with tap water for light/H2O2/Fe2+, and 8-fold in PET bottles with Lake Geneva water. The toxicological safety of the enhancements and their effects on the plastic container materials was assessed using the E-screen assay and the Ames test, after 1-day or 1-week exposure to SODIS, photo-Fenton and persulfate activation. Although the production of estrogenic compounds was observed, we report that no treatment method, duration of exposure or material resulted in estrogenicity risk for humans, and similarly, no mutagenicity risk was measured. In summary, we suggest that SODIS enhancement by either HO•- or SO4•--based advanced oxidation process is a suitable enhancement of bacterial inactivation in large scale plastic bottles, without any associated toxicity risks.
Collapse
Affiliation(s)
- Paloma Ozores Diez
- School of Biotechnology, Dublin City University (DCU), Glasnevin, Dublin 9, Ireland
| | - Stefanos Giannakis
- Universidad Politécnica de Madrid (UPM), E.T.S. Ingenieros de Caminos, Canales y Puertos, Departamento de Ingeniería Civil, Hidráulica, Energía y Medio Ambiente, Unidad docente Ingeniería Sanitaria, c/ Profesor Aranguren, s/n, Madrid, ES-28040, Spain.
| | - Jorge Rodríguez-Chueca
- School of Basic Sciences (SB), Institute of Chemical Science and Engineering (ISIC), Group of Advanced Oxidation Processes (GPAO), École Polytechnique Fédérale de Lausanne (EPFL), Station 6, Lausanne, CH-1015, Switzerland; Universidad Politécnica de Madrid (UPM), E.T.S. de Ingenieros Industriales, Departamento de Ingeniería Química Industrial y del Medio Ambiente, c/ de José Gutiérrez Abascal 2, Madrid, 28006, Spain
| | - Da Wang
- School of Basic Sciences (SB), Institute of Chemical Science and Engineering (ISIC), Group of Advanced Oxidation Processes (GPAO), École Polytechnique Fédérale de Lausanne (EPFL), Station 6, Lausanne, CH-1015, Switzerland; College of Environment, Zhejiang University of Technology, Hangzhou, 310032, China
| | - Bríd Quilty
- School of Biotechnology, Dublin City University (DCU), Glasnevin, Dublin 9, Ireland
| | - Rosaleen Devery
- School of Biotechnology, Dublin City University (DCU), Glasnevin, Dublin 9, Ireland
| | - Kevin McGuigan
- Department of Physiology & Medical Physics, Royal College of Surgeons in Ireland (RCSI), Dublin 2, Ireland
| | - Cesar Pulgarin
- School of Basic Sciences (SB), Institute of Chemical Science and Engineering (ISIC), Group of Advanced Oxidation Processes (GPAO), École Polytechnique Fédérale de Lausanne (EPFL), Station 6, Lausanne, CH-1015, Switzerland
| |
Collapse
|
5
|
Toxicity Reduction of Industrial and Municipal Wastewater by Advanced Oxidation Processes (Photo-Fenton, UVC/H2O2, Electro-Fenton and Galvanic Fenton): A Review. Catalysts 2020. [DOI: 10.3390/catal10060612] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
The application of Fenton-based advanced oxidation processes (AOPs), such as photo-Fenton or electro-Fenton for wastewater treatment have been extensively studied in recent decades due to its high efficiency for the decomposition of persistent organic pollutants. Usually Fenton-based AOPs are used for the degradation of targeted pollutant or group of pollutants, which often leads to the formation of toxic by-products possessing a potential environmental risk. In this work, we have collected and reviewed recent findings regarding the feasibility of Fenton-based AOPs (photo-Fenton, UVC/H2O2, electro-Fenton and galvanic Fenton) for the detoxification of real municipal and industrial wastewaters. More specifically, operational conditions, relevance and suitability of different bioassays for the toxicity assessment of various wastewater types, cost estimation, all of which compose current challenges for the application of these AOPs for real wastewater detoxification are discussed.
Collapse
|
6
|
Step by step procedures: Degradation of polycyclic aromatic hydrocarbons in potable water using photo-Fenton oxidation process. MethodsX 2019; 6:1701-1705. [PMID: 31388505 PMCID: PMC6676041 DOI: 10.1016/j.mex.2019.07.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds, composed of two or more fused benzene rings and abundantly found in mixed-use areas. Mixed-use areas consist of dense population, urbanization, industrial and agricultural activities. River pollution are common in mixed-use areas and 98% of Malaysia's fresh water supply originates from surface water. The biological degradation, adsorption and advanced oxidation process were documented as the available PAHs treatment for water. To date, the application of the photo-Fenton oxidation process has been reported for the treatment of PAHs from contaminated soil (review paper), landfill leachate, municipal solid waste leachate, sanitary landfill leachate, aniline wastewater, ammunition wastewater and saline aqueous solutions. As for potable water, the application of Fenton reagent was aided with photo treatment or electrolysis not focusing on PAHs removal. The presented MethodsX was conducted for PAHs degradation analysis in potable water samples using photo-Fenton oxidation process. The designed reactor for batch experiment is presented. The batch experiment consists of parameters like concentration of 17 USEPA-PAHs in the prepared aqueous solution (fixed variable), reaction time, pH and molarity ratio of hydrogen peroxide (H2O2): ferrous sulfate (FeSO4).
Collapse
|
7
|
Davididou K, Chatzisymeon E, Perez-Estrada L, Oller I, Malato S. Photo-Fenton treatment of saccharin in a solar pilot compound parabolic collector: Use of olive mill wastewater as iron chelating agent, preliminary results. JOURNAL OF HAZARDOUS MATERIALS 2019; 372:137-144. [PMID: 29567303 DOI: 10.1016/j.jhazmat.2018.03.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2017] [Revised: 03/06/2018] [Accepted: 03/09/2018] [Indexed: 06/08/2023]
Abstract
The aim of this work was to investigate the treatment of the artificial sweetener saccharin (SAC) in a solar compound parabolic collector pilot plant by means of the photo-Fenton process at pH 2.8. Olive mill wastewater (OMW) was used as iron chelating agent to avoid acidification of water at pH 2.8. For comparative purposes, Ethylenediamine-N, N-disuccinic acid (EDDS), a well-studied iron chelator, was also employed at circumneutral pH. Degradation products formed along treatment were identified by LC-QTOF-MS analysis. Their degradation was associated with toxicity removal, evaluated by monitoring changes in the bioluminescence of Vibrio fischeri bacteria. Results showed that conventional photo-Fenton at pH 2.8 could easily degrade SAC and its intermediates yielding k, apparent reaction rate constant, in the range of 0.64-0.82 L kJ-1, as well as, eliminate effluent's chronic toxicity. Both OMW and EDDS formed iron-complexes able to catalyse H2O2 decomposition and generate HO. OMW yielded lower SAC oxidation rates (k = 0.05-0.1 L kJ-1) than EDDS (k = 2.21-7.88 L kJ-1) possibly due to its higher TOC contribution. However, the degradation rates were improved (k = 0.13 L kJ-1) by increasing OMW dilution in the reactant mixture. All in all, encouraging results were obtained by using OMW as iron chelating agent, thus rendering this approach promising towards the increase of process sustainability.
Collapse
Affiliation(s)
- K Davididou
- School of Engineering, Institute for Infrastructure and Environment, The University of Edinburgh, Edinburgh EH9 3JL, United Kingdom
| | - E Chatzisymeon
- School of Engineering, Institute for Infrastructure and Environment, The University of Edinburgh, Edinburgh EH9 3JL, United Kingdom
| | - L Perez-Estrada
- Plataforma Solar de Almeria - CIEMAT, Carretera de Senés, km 4, 04200 Tabernas, Spain; CIESOL, Joint Centre of the University of Almería-CIEMAT, 04120 Almería, Spain
| | - I Oller
- Plataforma Solar de Almeria - CIEMAT, Carretera de Senés, km 4, 04200 Tabernas, Spain; CIESOL, Joint Centre of the University of Almería-CIEMAT, 04120 Almería, Spain
| | - S Malato
- Plataforma Solar de Almeria - CIEMAT, Carretera de Senés, km 4, 04200 Tabernas, Spain; CIESOL, Joint Centre of the University of Almería-CIEMAT, 04120 Almería, Spain.
| |
Collapse
|
8
|
Abd Manan TSB, Khan T, Sivapalan S, Jusoh H, Sapari N, Sarwono A, Ramli RM, Harimurti S, Beddu S, Sadon SN, Kamal NLM, Malakahmad A. Application of response surface methodology for the optimization of polycyclic aromatic hydrocarbons degradation from potable water using photo-Fenton oxidation process. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 665:196-212. [PMID: 30772550 DOI: 10.1016/j.scitotenv.2019.02.060] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Revised: 02/03/2019] [Accepted: 02/04/2019] [Indexed: 06/09/2023]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds, composed of benzene rings. The objective of this research was to identify the optimum condition for the degradation of PAHs contaminated water using photo-Fenton oxidation process via response surface methodology (RSM). Aqueous solution was prepared and potable water samples were collected from water treatment plants in Perak Tengah, Perak, Malaysia in September 2016. The reaction time, pH, molarity of H2O2 and FeSO4 were analyzed followed by RSM using aqueous solution. A five level central composite design with quadratic model was used to evaluate the effects and interactions of these parameters. The response variable was the percentage of total organic carbon (TOC) removal. PAHs quantification was done using gas chromatography mass spectrometry analysis. The regression line fitted well with the data with R2 value of 0.9757. The lack of fit test gives the highest value of Sum of Squares (15,666.64) with probability F value 0.0001 showing significant quadratic model. The optimum conditions were established corresponding to the percentage of TOC removal. The PAHs removal efficiency for potable water samples ranged from 76.4% to 91% following the first order of kinetic rates with R2 values of >0.95. Conventional water treatment techniques are not effective for PAHs removal. Thus, advanced oxidation processes may be considered as an alternative to conventional water treatment techniques in Malaysia and other developing countries.
Collapse
Affiliation(s)
- Teh Sabariah Binti Abd Manan
- Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.
| | - Taimur Khan
- Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Subarna Sivapalan
- Management & Humanities Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Hisyam Jusoh
- Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Nasiman Sapari
- Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Ariyanti Sarwono
- Department of Environmental Engineering, Pertamina University, Kebayoran Lama, 12220 Jakarta, Indonesia
| | - Raihan Mahirah Ramli
- Chemical Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | | | - Salmia Beddu
- Department of Civil Engineering, Universiti Tenaga Nasional, Jalan Ikram-Uniten, 43000 Kajang, Selangor Darul Ehsan, Malaysia
| | - Siti Nabihah Sadon
- Department of Civil Engineering, Universiti Tenaga Nasional, Jalan Ikram-Uniten, 43000 Kajang, Selangor Darul Ehsan, Malaysia
| | - Nur Liyana Mohd Kamal
- Department of Civil Engineering, Universiti Tenaga Nasional, Jalan Ikram-Uniten, 43000 Kajang, Selangor Darul Ehsan, Malaysia
| | - Amirhossein Malakahmad
- Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| |
Collapse
|
9
|
Ruíz-Delgado A, Roccamante M, Oller I, Agüera A, Malato S. Natural chelating agents from olive mill wastewater to enable photo-Fenton-like reactions at natural pH. Catal Today 2019. [DOI: 10.1016/j.cattod.2018.10.051] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
Mehrabadi Z, Faghihian H. Elimination of highly consumed herbicide; 2,4-dichlorophenoxyacetic acid from aqueous solution by TiO 2 impregnated clinoptilolite, study of degradation pathway. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 204:248-259. [PMID: 29936222 DOI: 10.1016/j.saa.2018.06.047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2018] [Revised: 06/09/2018] [Accepted: 06/12/2018] [Indexed: 06/08/2023]
Abstract
In this research, the degradation of the highly consumed herbicide, 2,4-dichlorophenoxy acetic acid, was evaluated by a nanophotocatalyst prepared by impregnation of natural zeolite clinoptilolite with TiO2. The photodegradation process of was studied under UV and visible light irradiations. To optimize the influencing parameters on the degradation efficiency, the Design Expert software and the Response surface methodology were used. The predicted values obtained by the methods were in good agreement with the experimental data. The degradation efficiency determined by UV-Vis spectroscopy indicated that the optimized degradation efficiency (58% by UV, and 31% by visible light) was obtained at pH = 6, catalyst dose of 0.4 g L-1, pollutant concentration of 6 mg L-1, and irradiation time of 95 min. The reaction mechanism was studied by Gaussian 03 program and a computer simulation method (density functional theory). The results were in good agreement with the results of the HPLC method used for identification of the degradation products. The mineralization of the pollutant was evaluated by measurement of total organic carbon of the degradation solution before and after irradiations. The results indicated that the degraded pollutant was mostly mineralized and converted to of CO2 and H2O.
Collapse
Affiliation(s)
- Zohreh Mehrabadi
- Department of Chemistry, Islamic Azad University, Shahreza Branch, Shahreza, Iran
| | - Hossein Faghihian
- Department of Chemistry, Islamic Azad University, Shahreza Branch, Shahreza, Iran.
| |
Collapse
|
11
|
Giannakis S. Analogies and differences among bacterial and viral disinfection by the photo-Fenton process at neutral pH: a mini review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:27676-27692. [PMID: 29255985 DOI: 10.1007/s11356-017-0926-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 12/03/2017] [Indexed: 04/16/2023]
Abstract
Over the last years, the photo-Fenton process has been established as an effective, green alternative to chemical disinfection of waters and wastewaters. Microorganisms' inactivation is the latest success story in the application of this process at near-neutral pH, albeit without clearly elucidated inactivation mechanisms. In this review, the main pathways of the combined photo-Fenton process against the most frequent pathogen models (Escherichia coli for bacteria and MS2 bacteriophage for viruses) are analyzed. Firstly, the action of solar light is described and the specific inactivation mechanisms in bacteria (internal photo-Fenton) and viruses (genome damage) are presented. The contribution of the external pathways due to the potential presence of organic matter in generating reactive oxygen species (ROS) and their effects on microorganism inactivation are discussed. Afterwards, the effects of the gradual addition of Fe and H2O2 are assessed and the differences among bacterial and viral inactivation are highlighted. As a final step, the simultaneous addition of both reagents induces the photo-Fenton in the bulk, focusing on the differences induced by the homogeneous or heterogeneous fraction of the process and the variation among the two respective targets. This work exploits the accumulated evidence on the mechanisms of bacterial inactivation and the scarce ones towards viral targets, aiming to bridge this knowledge gap and make possible the further application of the photo-Fenton process in the field of water/wastewater treatment.
Collapse
Affiliation(s)
- Stefanos Giannakis
- School of Basic Sciences (SB), Institute of Chemical Science and Engineering (ISIC), Group of Advanced Oxidation Processes (GPAO), École Polytechnique Fédérale de Lausanne (EPFL), Station 6, 1015, Lausanne, Switzerland.
| |
Collapse
|
12
|
Giraldo-Aguirre AL, Serna-Galvis EA, Erazo-Erazo ED, Silva-Agredo J, Giraldo-Ospina H, Flórez-Acosta OA, Torres-Palma RA. Removal of β-lactam antibiotics from pharmaceutical wastewaters using photo-Fenton process at near-neutral pH. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:20293-20303. [PMID: 28160176 DOI: 10.1007/s11356-017-8420-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Accepted: 01/05/2017] [Indexed: 06/06/2023]
Abstract
In this work, the photo-Fenton process at near-neutral pH was applied for the removal of the β-lactam antibiotic oxacillin (OXA) in water using artificial and sunlight. Initially, the main variables of the process (Fe(II), H2O2, and light power) were optimized by a statistical factorial design (23 with center points). The experimental design indicated that 90 μmol L-1 of Fe(II), 10 mmol L-1 of H2O2, and 30 W of power light were the favorable conditions for degradation of OXA at 203 μmol L-1. In the photo-Fenton system, the H2O2 alone, UV-light/H2O2, and Fe(II)/H2O2 subsystems presented a significant participation on antibiotic removal. Moreover, based on the primary organic transformation products, a mechanism of OXA degradation was proposed. Under the favorable operational conditions, both the pollutant and the antimicrobial activity were eliminated after 50 min of process application. Although at 480 min of treatment, only 5% of mineralization was achieved, the level of biodegradability of the solutions increased from 0.08 to 0.98. Interestingly, the presence of pharmaceutical additives (glucose, isopropanol, and oxalic acid) had a moderate interference on the efficiency of the pollutant removal. Additionally, the treatment at pilot scale of the β-lactam antibiotic in a pharmaceutical complex matrix using solar radiation allowed the complete removal of the pollutant and its associated antimicrobial activity in a very short time period (5 min). These results evidenced the applicability of the photo-Fenton process to treat wastewaters from pharmaceutical industry loaded with β-lactam antibiotics at near neutral pH values efficiently.
Collapse
Affiliation(s)
- Ana L Giraldo-Aguirre
- Grupo de Diseño y Formulación de Medicamentos, Cosméticos y Afines (DYFOMECO), Facultad de Ciencias Farmacéuticas y Alimentarias, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Efraím A Serna-Galvis
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Edgar D Erazo-Erazo
- Grupo de Diseño y Formulación de Medicamentos, Cosméticos y Afines (DYFOMECO), Facultad de Ciencias Farmacéuticas y Alimentarias, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Javier Silva-Agredo
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Héctor Giraldo-Ospina
- Grupo de Diseño y Formulación de Medicamentos, Cosméticos y Afines (DYFOMECO), Facultad de Ciencias Farmacéuticas y Alimentarias, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Oscar A Flórez-Acosta
- Grupo de Diseño y Formulación de Medicamentos, Cosméticos y Afines (DYFOMECO), Facultad de Ciencias Farmacéuticas y Alimentarias, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Ricardo A Torres-Palma
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
| |
Collapse
|
13
|
Gutiérrez-Zapata HM, Alvear-Daza JJ, Rengifo-Herrera JA, Sanabria J. Addition of Hydrogen Peroxide to Groundwater with Natural Iron Induces Water Disinfection by Photo-Fenton at Circumneutral pH and other Photochemical Events. Photochem Photobiol 2017; 93:1224-1231. [DOI: 10.1111/php.12779] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Accepted: 03/17/2017] [Indexed: 01/21/2023]
Affiliation(s)
- Héctor Mario Gutiérrez-Zapata
- Environmental Microbiology and Biotechnology Laboratory; Engineering School of Environmental & Natural Resources; Engineering Faculty; Universidad del Valle - Sede Meléndez; Cali Colombia
| | - John Jairo Alvear-Daza
- Environmental Microbiology and Biotechnology Laboratory; Engineering School of Environmental & Natural Resources; Engineering Faculty; Universidad del Valle - Sede Meléndez; Cali Colombia
| | - Julián Andrés Rengifo-Herrera
- Centro de Investigación y Desarrollo en Ciencias Aplicadas “Dr. J.J. Ronco” (CINDECA); Departamento de Química; Facultad de Ciencias Exactas; UNLP-CCT La Plata; La Plata Buenos Aires Argentina
| | - Janeth Sanabria
- Environmental Microbiology and Biotechnology Laboratory; Engineering School of Environmental & Natural Resources; Engineering Faculty; Universidad del Valle - Sede Meléndez; Cali Colombia
| |
Collapse
|
14
|
Conte LO, Schenone AV, Alfano OM. Photo-Fenton degradation of the herbicide 2,4-D in aqueous medium at pH conditions close to neutrality. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2016; 170:60-9. [PMID: 26800432 DOI: 10.1016/j.jenvman.2016.01.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Revised: 12/29/2015] [Accepted: 01/03/2016] [Indexed: 05/23/2023]
Abstract
A theoretical and experimental study of the photo-Fenton degradation of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) in water is presented. A kinetic model derived from a reaction sequence is proposed using the ferrioxalate complex as iron source for conditions of pH = 5. The kinetic model was employed to predict the concentrations of 2,4-D, 2,4-dichlorophenol (2,4-DCP), hydrogen peroxide (HP) and oxalate (Ox) in a flat plate laboratory reactor irradiated with a solar simulator. Two types of incident irradiation levels were tested by different combinations of attenuation filters. The effects of the oxalate/Fe(+3) molar ratio (Ox/Fe), the reaction temperature (T) and the 2,4-D/HP molar ratio (R) on the photo-Fenton process were also investigated. For low radiation level and operating conditions of R = 50 and T = 50 °C, a 2,4-D conversion of 95.6% was obtained after 180 min. Moreover, the 2,4-D conversion was almost 100% in only 120 min when the system was operated under the same operating conditions and high radiation level. From the proposed model and the experimental data, the corresponding kinetic parameters were estimated applying a nonlinear regression method. A good agreement between the kinetic model and experimental data, for a wide range of simulated solar operating conditions, was observed. For 2,4-D, 2,4-DCP, HP and Ox concentrations, the calculated RMSE were 1.21 × 10(-2), 5.45 × 10(-3), 2.86 × 10(-1) and 2.65 × 10(-2) mM, respectively.
Collapse
Affiliation(s)
- Leandro O Conte
- INTEC (CONICET-UNL), Ruta Nacional Nº 168, 3000, Santa Fe, Argentina
| | | | - Orlando M Alfano
- INTEC (CONICET-UNL), Ruta Nacional Nº 168, 3000, Santa Fe, Argentina.
| |
Collapse
|
15
|
Tian Y, Yuan X, Xu S, Li R, Zhou X, Zhang Z. Biological efficacy and toxic effect of emergency water disinfection process based on advanced oxidation technology. ECOTOXICOLOGY (LONDON, ENGLAND) 2015; 24:2141-2150. [PMID: 26427371 DOI: 10.1007/s10646-015-1559-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 09/24/2015] [Indexed: 06/05/2023]
Abstract
An innovative and removable water treatment system consisted of strong electric field discharge and hydrodynamic cavitation based on advanced oxidation technologies was developed for reactive free radicals producing and waterborne pathogens eliminating in the present study. The biological efficacy and toxic effects of this advanced oxidation system were evaluated during water disinfection treatments. Bench tests were carried out with synthetic microbial-contaminated water, as well as source water in rainy season from a reservoir of Dalian city (Liaoning Province, China). Results showed that high inactivation efficiency of Escherichia coli (>5 log) could be obtained for synthetic contaminated water at a low concentration (0.5-0.7 mg L(-1)) of total oxidants in 3-10 s. The numbers of wild total bacteria (108 × 10(3) CFU mL(-1)) and total coliforms (260 × 10(2) MPN 100 mL(-1)) in source water greatly reduced to 50 and 0 CFU mL(-1) respectively after treated by the advanced oxidation system, which meet the microbiological standards of drinking water, and especially that the inactivation efficiency of total coliforms could reach 100%. Meanwhile, source water qualities were greatly improved during the disinfection processes. The values of UV254 in particular were significantly reduced (60-80%) by reactive free radicals. Moreover, the concentrations of possible disinfection by-products (formaldehyde and bromide) in treated water were lower than detection limits, indicating that there was no harmful effect on water after the treatments. These investigations are helpful for the ecotoxicological studies of advanced oxidation system in the treatments of chemical polluted water or waste water. The findings of this work suggest that the developed water treatment system is ideal in the acute phases of emergencies, which also could offer additional advantages over a wide range of applications in water pollution control.
Collapse
Affiliation(s)
- Yiping Tian
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China
| | - Xiaoli Yuan
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China
| | - Shujing Xu
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China
| | - Rihong Li
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China
| | - Xinying Zhou
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China
| | - Zhitao Zhang
- Environmental Engineering Institute, Dalian Maritime University, 1 Linghai Road, Dalian, 116026, Liaoning, China.
| |
Collapse
|
16
|
Tsydenova O, Batoev V, Batoeva A. Solar-Enhanced Advanced Oxidation Processes for Water Treatment: Simultaneous Removal of Pathogens and Chemical Pollutants. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2015; 12:9542-61. [PMID: 26287222 PMCID: PMC4555297 DOI: 10.3390/ijerph120809542] [Citation(s) in RCA: 86] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Revised: 07/19/2015] [Accepted: 07/27/2015] [Indexed: 11/16/2022]
Abstract
The review explores the feasibility of simultaneous removal of pathogens and chemical pollutants by solar-enhanced advanced oxidation processes (AOPs). The AOPs are based on in-situ generation of reactive oxygen species (ROS), most notably hydroxyl radicals •OH, that are capable of destroying both pollutant molecules and pathogen cells. The review presents evidence of simultaneous removal of pathogens and chemical pollutants by photocatalytic processes, namely TiO2 photocatalysis and photo-Fenton. Complex water matrices with high loads of pathogens and chemical pollutants negatively affect the efficiency of disinfection and pollutant removal. This is due to competition between chemical substances and pathogens for generated ROS. Other possible negative effects include light screening, competitive photon absorption, adsorption on the catalyst surface (thereby inhibiting its photocatalytic activity), etc. Besides, some matrix components may serve as nutrients for pathogens, thus hindering the disinfection process. Each type of water/wastewater would require a tailor-made approach and the variables that were shown to influence the processes-catalyst/oxidant concentrations, incident radiation flux, and pH-need to be adjusted in order to achieve the required degree of pollutant and pathogen removal. Overall, the solar-enhanced AOPs hold promise as an environmentally-friendly way to substitute or supplement conventional water/wastewater treatment, particularly in areas without access to centralized drinking water or sewage/wastewater treatment facilities.
Collapse
Affiliation(s)
- Oyuna Tsydenova
- Baikal Institute of Nature Management, Siberian Branch of the Russian Academy of Sciences, Sakhyanova st. 6, Ulan-Ude City 670047, Russia.
| | - Valeriy Batoev
- Baikal Institute of Nature Management, Siberian Branch of the Russian Academy of Sciences, Sakhyanova st. 6, Ulan-Ude City 670047, Russia.
| | - Agniya Batoeva
- Baikal Institute of Nature Management, Siberian Branch of the Russian Academy of Sciences, Sakhyanova st. 6, Ulan-Ude City 670047, Russia.
| |
Collapse
|