1
|
Lopez Carrasco I, Cuniberti G, Opitz J, Beshchasna N. Evaluation of Transducer Elements Based on Different Material Configurations for Aptamer-Based Electrochemical Biosensors. BIOSENSORS 2024; 14:341. [PMID: 39056617 PMCID: PMC11274616 DOI: 10.3390/bios14070341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/28/2024]
Abstract
The selection of an appropriate transducer is a key element in biosensor development. Currently, a wide variety of substrates and working electrode materials utilizing different fabrication techniques are used in the field of biosensors. In the frame of this study, the following three specific material configurations with gold-finish layers were investigated regarding their efficacy to be used as electrochemical (EC) biosensors: (I) a silicone-based sensor substrate with a layer configuration of 50 nm SiO/50 nm SiN/100 nm Au/30-50 nm WTi/140 nm SiO/bulk Si); (II) polyethylene naphthalate (PEN) with a gold inkjet-printed layer; and (III) polyethylene terephthalate (PET) with a screen-printed gold layer. Electrodes were characterized using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) to evaluate their performance as electrochemical transducers in an aptamer-based biosensor for the detection of cardiac troponin I using the redox molecule hexacyanoferrade/hexacyaniferrade (K3[Fe (CN)6]/K4[Fe (CN)6]. Baseline signals were obtained from clean electrodes after a specific cleaning procedure and after functionalization with the thiolate cardiac troponin I aptamers "Tro4" and "Tro6". With the goal of improving the PEN-based and PET-based performance, sintered PEN-based samples and PET-based samples with a carbon or silver layer under the gold were studied. The effect of a high number of immobilized aptamers will be tested in further work using the PEN-based sample. In this study, the charge-transfer resistance (Rct), anodic peak height (Ipa), cathodic peak height (Ipc) and peak separation (∆E) were determined. The PEN-based electrodes demonstrated better biosensor properties such as lower initial Rct values, a greater change in Rct after the immobilization of the Tro4 aptamer on its surface, higher Ipc and Ipa values and lower ∆E, which correlated with a higher number of immobilized aptamers compared with the other two types of samples functionalized using the same procedure.
Collapse
Affiliation(s)
- Ivan Lopez Carrasco
- Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany; (I.L.C.); (J.O.)
| | - Gianaurelio Cuniberti
- Faculty of Mechanical Science and Engineering, Institute of Materials Science and Max Bergmann Center of Biomaterials, Technische Universität Dresden, 01062 Dresden, Germany;
| | - Jörg Opitz
- Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany; (I.L.C.); (J.O.)
| | - Natalia Beshchasna
- Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany; (I.L.C.); (J.O.)
| |
Collapse
|
2
|
Zhang Y, Duan H, Li G, Peng M, Ma X, Li M, Yan S. Construction of liquid metal-based soft microfluidic sensors via soft lithography. J Nanobiotechnology 2022; 20:246. [PMID: 35643573 PMCID: PMC9148490 DOI: 10.1186/s12951-022-01471-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 05/19/2022] [Indexed: 01/08/2023] Open
Abstract
Background Liquid metal (LM) can be integrated into microfluidic channel, bringing new functionalities of microfluidics and opening a new window for soft microfluidic electronics, due to the superior advantages of the conductivity and deformability of LMs. However, patterning the LMs into microfluidic channels requires either selective surface wetting or complex fabrication process. Results In this work, we develop a method to pattern the LMs onto the soft elastomer via soft lithographic process for fabrication of soft microfluidic sensors without the surface modification, bulky facilities, and complicated processes. The combination of the interfacial hydrogen bond and surface tension enables the LM patterns transfer to the soft elastomer. The transferred LM patterns with an ellipse-like cross-section further improve the stability under the mechanical deformation. Three proof-of-concept experiments were conducted to demonstrate the utilization of this method for development of thermochromic sensors, self-powered capacity sensors and flexible biosensor for glucose detection. Conclusions In summary, the proposed method offers a new patterning method to obtain soft microfluidic sensors and brings new possibilities for microfluidics-related wearable devices. Graphical Abstract ![]()
Supplementary Information The online version contains supplementary material available at 10.1186/s12951-022-01471-0.
Collapse
|
3
|
Bariya M, Li L, Ghattamaneni R, Ahn CH, Nyein HYY, Tai LC, Javey A. Glove-based sensors for multimodal monitoring of natural sweat. SCIENCE ADVANCES 2020; 6:eabb8308. [PMID: 32923646 PMCID: PMC7455190 DOI: 10.1126/sciadv.abb8308] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 07/15/2020] [Indexed: 05/18/2023]
Abstract
Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.
Collapse
Affiliation(s)
- Mallika Bariya
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Lu Li
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Rahul Ghattamaneni
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
| | - Christine Heera Ahn
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
| | - Hnin Yin Yin Nyein
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Li-Chia Tai
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Ali Javey
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| |
Collapse
|
4
|
Zhao Y, Wang B, Hojaiji H, Wang Z, Lin S, Yeung C, Lin H, Nguyen P, Chiu K, Salahi K, Cheng X, Tan J, Cerrillos BA, Emaminejad S. A wearable freestanding electrochemical sensing system. SCIENCE ADVANCES 2020; 6:eaaz0007. [PMID: 32219164 PMCID: PMC7083607 DOI: 10.1126/sciadv.aaz0007] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 12/23/2019] [Indexed: 05/24/2023]
Abstract
To render high-fidelity wearable biomarker data, understanding and engineering the information delivery pathway from epidermally retrieved biofluid to a readout unit are critical. By examining the biomarker information delivery pathway and recognizing near-zero strained regions within a microfluidic device, a strain-isolated pathway to preserve biomarker data fidelity is engineered. Accordingly, a generalizable and disposable freestanding electrochemical sensing system (FESS) is devised, which simultaneously facilitates sensing and out-of-plane signal interconnection with the aid of double-sided adhesion. The FESS serves as a foundation to realize a system-level design strategy, addressing the challenges of wearable biosensing, in the presence of motion, and integration with consumer electronics. To this end, a FESS-enabled smartwatch was developed, featuring sweat sampling, electrochemical sensing, and data display/transmission, all within a self-contained wearable platform. The FESS-enabled smartwatch was used to monitor the sweat metabolite profiles of individuals in sedentary and high-intensity exercise settings.
Collapse
Affiliation(s)
- Yichao Zhao
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Bo Wang
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Hannaneh Hojaiji
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Zhaoqing Wang
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Shuyu Lin
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Christopher Yeung
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Haisong Lin
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Peterson Nguyen
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- College of Letters and Sciences, University of California, Los Angeles, Los Angeles, CA, USA
| | - Kaili Chiu
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- College of Letters and Sciences, University of California, Los Angeles, Los Angeles, CA, USA
| | - Kamyar Salahi
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Xuanbing Cheng
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Jiawei Tan
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Betto Alcitlali Cerrillos
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| | - Sam Emaminejad
- Interconnected & Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA, USA
| |
Collapse
|
5
|
Electroanalytical cells pencil drawn on PVC supports and their use for the detection in flexible microfluidic devices. Talanta 2019; 199:14-20. [DOI: 10.1016/j.talanta.2019.01.126] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 01/17/2019] [Accepted: 01/22/2019] [Indexed: 01/26/2023]
|
6
|
Yu T, Zhang H, Huang Z, Luo Z, Huang N, Ding S, Feng W. A Simple Electrochemical Aptamer Cytosensor for Direct Detection of Chronic Myelogenous Leukemia K562 Cells. ELECTROANAL 2016. [DOI: 10.1002/elan.201600505] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Tianxiao Yu
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Hui Zhang
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Zhenglan Huang
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Zhenhong Luo
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Ningshu Huang
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Shijia Ding
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| | - Wenli Feng
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine; Chongqing Medical University; Chongqing 400016 China
| |
Collapse
|
7
|
Mostafalu P, Nezhad AS, Nikkhah M, Akbari M. Flexible Electronic Devices for Biomedical Applications. ACTA ACUST UNITED AC 2016. [DOI: 10.1007/978-3-319-32180-6_16] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
8
|
Masi M, Gamella M, Guz N, Katz E. Electrochemically Triggered DNA Release from a Mixed-brush Polymer-modified Electrode. ELECTROANAL 2016. [DOI: 10.1002/elan.201600275] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Madeline Masi
- Department of Chemistry and Biomolecular Science; Clarkson University; Potsdam NY 13699-5810 USA
| | - Maria Gamella
- Department of Chemistry and Biomolecular Science; Clarkson University; Potsdam NY 13699-5810 USA
| | - Nataliia Guz
- Department of Chemistry and Biomolecular Science; Clarkson University; Potsdam NY 13699-5810 USA
| | - Evgeny Katz
- Department of Chemistry and Biomolecular Science; Clarkson University; Potsdam NY 13699-5810 USA
| |
Collapse
|
9
|
Shanmugam NR, Muthukumar S, Prasad S. Ultrasensitive and low-volume point-of-care diagnostics on flexible strips - a study with cardiac troponin biomarkers. Sci Rep 2016; 6:33423. [PMID: 27634488 PMCID: PMC5025736 DOI: 10.1038/srep33423] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Accepted: 08/22/2016] [Indexed: 12/22/2022] Open
Abstract
We demonstrate a flexible, mechanically stable, and disposable electrochemical sensor platform for monitoring cardiac troponins through the detection and quantification of cardiac Troponin-T (cTnT). We designed and fabricated nanostructured zinc oxide (ZnO) sensing electrodes on flexible porous polyimide substrates. We demonstrate ultrasensitive detection is capable at very low sample volumes due to the confinement phenomenon of target species within the ZnO nanostructures leading to enhancement of biomolecular binding on the sensor electrode surface. The performance of the ZnO nanostructured sensor electrode was evaluated against gold and nanotextured ZnO electrodes. The electrochemical sensor functions on affinity based immunoassay principles whereby monoclonal antibodies for cTnT were immobilized on the sensor electrodes using thiol based chemistry. Detection of cTnT in phosphate buffered saline (PBS) and human serum (HS) buffers was achieved at low sample volumes of 20 μL using non-faradaic electrochemical impedance spectroscopy (EIS). Limit of detection (LOD) of 1E-4 ng/mL (i.e. 1 pg/mL) at 7% CV (coefficient of variation) for cTnT in HS was demonstrated on nanostructured ZnO electrodes. The mechanical integrity of the flexible biosensor platform was demonstrated with cyclic bending tests. The sensor performed within 12% CV after 100 bending cycles demonstrating the robustness of the nanostructured ZnO electrochemical sensor platform.
Collapse
Affiliation(s)
| | | | - Shalini Prasad
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
| |
Collapse
|
10
|
Bandodkar AJ, Jeerapan I, You JM, Nuñez-Flores R, Wang J. Highly Stretchable Fully-Printed CNT-Based Electrochemical Sensors and Biofuel Cells: Combining Intrinsic and Design-Induced Stretchability. NANO LETTERS 2016; 16:721-7. [PMID: 26694819 PMCID: PMC4713296 DOI: 10.1021/acs.nanolett.5b04549] [Citation(s) in RCA: 132] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
We present the first example of an all-printed, inexpensive, highly stretchable CNT-based electrochemical sensor and biofuel cell array. The synergistic effect of utilizing specially tailored screen printable stretchable inks that combine the attractive electrical and mechanical properties of CNTs with the elastomeric properties of polyurethane as a binder along with a judiciously designed free-standing serpentine pattern enables the printed device to possess two degrees of stretchability. Owing to these synergistic design and nanomaterial-based ink effects, the device withstands extremely large levels of strains (up to 500% strain) with negligible effect on its structural integrity and performance. This represents the highest stretchability offered by a printed device reported to date. Extensive electrochemical characterization of the printed device reveal that repeated stretching, torsional twisting, and indenting stress has negligible impact on its electrochemical properties. The wide-range applicability of this platform to realize highly stretchable CNT-based electrochemical sensors and biofuel cells has been demonstrated by fabricating and characterizing potentiometric ammonium sensor, amperometric enzyme-based glucose sensor, enzymatic glucose biofuel cell, and self-powered biosensor. Highly stretchable printable multianalyte sensor, multifuel biofuel cell, or any combination thereof can thus be realized using the printed CNT array. Such combination of intrinsically stretchable printed nanomaterial-based electrodes and strain-enduring design patterns holds considerable promise for creating an attractive class of inexpensive multifunctional, highly stretchable printed devices that satisfy the requirements of diverse healthcare and energy fields wherein resilience toward extreme mechanical deformations is mandatory.
Collapse
Affiliation(s)
| | | | | | | | - Joseph Wang
- ; Fax: +1 (858) 534 9553; Tel: +1 (858) 246 0128
| |
Collapse
|
11
|
Zhang W, Zhu S, Luque R, Han S, Hu L, Xu G. Recent development of carbon electrode materials and their bioanalytical and environmental applications. Chem Soc Rev 2016; 45:715-52. [DOI: 10.1039/c5cs00297d] [Citation(s) in RCA: 210] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
New synthetic approaches, materials, properties, electroanalytical applications and perspectives of carbon materials are presented.
Collapse
Affiliation(s)
- Wei Zhang
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun
- China
| | - Shuyun Zhu
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun
- China
| | - Rafael Luque
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun
- China
| | - Shuang Han
- Shenyang University of Chemical Technology
- Shenyang
- China
| | - Lianzhe Hu
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun
- China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun
- China
| |
Collapse
|
12
|
Bandodkar AJ, Nuñez-Flores R, Jia W, Wang J. All-printed stretchable electrochemical devices. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2015; 27:3060-3065. [PMID: 25856153 DOI: 10.1002/adma.201500768] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 03/13/2015] [Indexed: 06/04/2023]
Abstract
The fabrication and characterization of all-printed, inexpensive, stretchable electrochemical devices is described. These devices are based on specially engineered inks that can withstand severe tensile strain, as high as 100%, without any significant effect on their electrochemical properties. Such stretchable electrochemical devices should be attractive for diverse sensing and energy applications.
Collapse
Affiliation(s)
- Amay J Bandodkar
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Rogelio Nuñez-Flores
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Wenzhao Jia
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Joseph Wang
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| |
Collapse
|
13
|
Katz E. Implantable Biofuel Cells Operating In Vivo—Potential Power Sources for Bioelectronic Devices. Bioelectron Med 2015. [DOI: 10.15424/bioelectronmed.2014.00011] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
14
|
Foster CW, Metters JP, Kampouris DK, Banks CE. Ultraflexible Screen-Printed Graphitic Electroanalytical Sensing Platforms. ELECTROANAL 2014. [DOI: 10.1002/elan.201300563] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
15
|
Xue J, Henry C, Lee J, Vogt BD. Large area, flexible ordered mesoporous carbon films from soft templating on polymer substrates. RSC Adv 2014. [DOI: 10.1039/c3ra44723e] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
16
|
Foster CW, Metters JP, Banks CE. Ultra Flexible Paper Based Electrochemical Sensors: Effect of Mechanical Contortion upon Electrochemical Performance. ELECTROANAL 2013. [DOI: 10.1002/elan.201300274] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
|
18
|
Silva BVM, Cavalcanti IT, Mattos AB, Moura P, Sotomayor MDPT, Dutra RF. Disposable immunosensor for human cardiac troponin T based on streptavidin-microsphere modified screen-printed electrode. Biosens Bioelectron 2010; 26:1062-7. [PMID: 20863683 DOI: 10.1016/j.bios.2010.08.051] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Revised: 08/14/2010] [Accepted: 08/17/2010] [Indexed: 10/19/2022]
Abstract
Screen-printed electrodes (SPE) have been widely used in the design of disposable sensors bringing advances in the use of electrochemical immunosensors for in field-clinical analysis. In this work, streptavidin polystyrene microspheres were incorporated to the electrode surface of SPEs in order to increase the analytical response of the cardiac troponin T (cTnT), a specific biomarker for the acute myocardial infarction diagnosis. The precise calculation of the stoichiometric streptavidin-biotin ratio [1:4] allowed the increase of sensitivity and stability of the immunosensor response to the cTnT analyte. The surface of the immunosensor was characterized by scanning electron microscopy and cyclic voltammetry. It was observed that the use of streptavidin microspheres significantly increased the analytical sensitivity of the electrode in 8.5 times, showing a curve with a linear response range between 0.1 and 10 ngmL(-1) of cTnT and a detection limit of 0.2 ngmL(-1). The proposed SPE showed ease preparation and high sensitivity allowing the detection of cTnT in the range of clinical levels. The new device coupled with a portable electrochemical analyzer shows great promise for point-of-care quantitative testing of necrosis cardiac proteins.
Collapse
Affiliation(s)
- Bárbara V M Silva
- Laboratório de Pesquisa em Diagnóstico/LAPED, Pronto Socorro Cardiológico de Pernambuco/PROCAPE, Universidade de Pernambuco, Rua dos Palmares, s/n, 50100-130 Recife-PE, Brazil
| | | | | | | | | | | |
Collapse
|
19
|
Yun J, Cho K, Kim S. Flexible logic circuits composed of chalcogenide-nanocrystal-based thin film transistors. NANOTECHNOLOGY 2010; 21:235204. [PMID: 20472946 DOI: 10.1088/0957-4484/21/23/235204] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Complementary NAND and NOR gates composed of p-channel HgTe-nanocrystal (NC) films and n-channel HgSe-NC films were constructed on back-gate patterned plastic substrates. The NAND gate was made of two HgTe-p-channel thin film transistors (TFTs) in parallel and two HgSe-n-channel TFTs in series. The NOR gate was built up with both two HgSe-n-channel TFTs in parallel and two HgTe-p-channel TFTs in series. The mobility and on/off ratio for the p-channel TFTs were estimated to be 0.9 cm(2) V(-1) s(-1) and 10, respectively, and those for the n-channel TFTs were measured to be 1.8 cm(2) V(-1) s(-1) and 10(2), respectively. The NAND and NOR gates were operated with gains of 1.45 and 1.63 and transition widths of 7.8 and 6.2 V, respectively, at room temperature in air. In addition, the operations of the NAND and NOR logics are reproducible for up to 1000 strain cycles.
Collapse
Affiliation(s)
- Junggwon Yun
- Department of Electrical Engineering, Korea University, Seoul, Korea
| | | | | |
Collapse
|
20
|
Yang YL, Chuang MC, Lou SL, Wang J. Thick-film textile-based amperometric sensors and biosensors. Analyst 2010; 135:1230-4. [PMID: 20498876 DOI: 10.1039/b926339j] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The incorporation of amperometric sensors into clothing through direct screen-printing onto the textile substrate is described. Particular attention is given to electrochemical sensors printed directly on the elastic waist of underwear that offers tight direct contact with the skin. The textile-based printed carbon electrodes have a well-defined appearance with relatively smooth conductor edges and no apparent defects or cracks. Convenient voltammetric and chronoamperometric measurements of 0-3 mM ferrocyanide, 0-25 mM hydrogen peroxide, and 0-100 muM NADH have been documented. The favorable electrochemical behavior is maintained under folding or stretching stress, relevant to the deformation of clothing. The electrochemical performance and tolerance to mechanical stress are influenced by the physical characteristics of the textile substrate. The results indicate the potential of textile-based screen-printed amperometric sensors for future healthcare, sport or military applications. Such future applications would benefit from tailoring the ink composition and printing conditions to meet the specific requirements of the textile substrate.
Collapse
Affiliation(s)
- Yang-Li Yang
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | | | | | | |
Collapse
|
21
|
Choudry NA, Kampouris DK, Kadara RO, Banks CE. Disposable highly ordered pyrolytic graphite-like electrodes: Tailoring the electrochemical reactivity of screen printed electrodes. Electrochem commun 2010. [DOI: 10.1016/j.elecom.2009.10.021] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|