1
|
Zhang Y, Li M, Li H. A vertical/horizontal graphene-based microneedle plant sensor for on-site detection of indole-3-acetic acid in vegetables. Talanta 2025; 283:127114. [PMID: 39467443 DOI: 10.1016/j.talanta.2024.127114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 10/22/2024] [Accepted: 10/25/2024] [Indexed: 10/30/2024]
Abstract
Plant hormones are important regulators of crop growth and production. In this study, an in situ electrochemical sensor was successfully built using flat microelectrodes with horizontally and vertically grown graphene to detect the plant regulator indole-3-acetic acid (IAA) in plants. Vertical and horizontal graphene layers were prepared by electron-assisted hot-filament chemical vapor deposition. Vertical graphene nanosheets were grown on a horizontal graphene layer as sensing electrodes, and a microneedle sensor was assembled by combining Pt and Ti microelectrodes. The vertical/horizontal graphene (VHG) microneedle sensor can rapidly detect IAA levels in various plants in situ over a wide pH range of 4.0-9.0 and concentration range of 1-100 μM, with a minimum detection limit of 0.21 μM (3σ/S). Subsequently, this microneedle sensor was used to determine the IAA content in different tissues of cucumber and cauliflower stems with satisfactory results. The combination of VHG microelectrode arrays and small electrochemical workstations is useful for constructing portable, low-cost, on-site, and fast electrochemical sensing platforms for plant growth monitoring.
Collapse
Affiliation(s)
- Yangyang Zhang
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, 300384, PR China
| | - Mingji Li
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, 300384, PR China.
| | - Hongji Li
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin, 300384, PR China
| |
Collapse
|
2
|
He X, Wang S, Ma C, Xu GR, Ma J, Xie H, Zhu W, Liu H, Wang L, Wang Y. Utilizing Electrochemical Biosensors as an Innovative Platform for the Rapid and On-Site Detection of Animal Viruses. Animals (Basel) 2023; 13:3141. [PMID: 37835747 PMCID: PMC10571726 DOI: 10.3390/ani13193141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/19/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023] Open
Abstract
Animal viruses are a significant threat to animal health and are easily spread across the globe with the rise of globalization. The limitations in diagnosing and treating animal virus infections have made the transmission of diseases and animal deaths unpredictable. Therefore, early diagnosis of animal virus infections is crucial to prevent the spread of diseases and reduce economic losses. To address the need for rapid diagnosis, electrochemical sensors have emerged as promising tools. Electrochemical methods present numerous benefits, including heightened sensitivity and selectivity, affordability, ease of use, portability, and rapid analysis, making them suitable for real-time virus detection. This paper focuses on the construction of electrochemical biosensors, as well as promising biosensor models, and expounds its advantages in virus detection, which is a promising research direction.
Collapse
Affiliation(s)
- Xun He
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Shan Wang
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Caoyuan Ma
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Guang-Ri Xu
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Jinyou Ma
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Hongbing Xie
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Wei Zhu
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
| | - Hongyang Liu
- Shuangliao Animal Disease Control Center, Siping 136400, China;
| | - Lei Wang
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
- Ministry of Education Key Laboratory for Animal Pathogens and Biosafety, Zhengzhou 450046, China
| | - Yimin Wang
- Henan Institute of Science and Technology, Xinxiang 453003, China; (X.H.); (S.W.); (C.M.); (G.-R.X.); (J.M.); (H.X.); (W.Z.)
- Ministry of Education Key Laboratory for Animal Pathogens and Biosafety, Zhengzhou 450046, China
| |
Collapse
|
3
|
Hieu NN, Nguyen CV, Phuc HV, Hoi BD. On the impact of adsorbed gas molecules on the anisotropic electro-optical properties of β 12-borophene. Phys Chem Chem Phys 2023; 25:23829-23835. [PMID: 37641558 DOI: 10.1039/d3cp01938a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
We theoretically study the role of adsorbed gas molecules on the electronic and optical properties of monolayer β12-borophene with {a,b,c,d,e} atoms in its unit cell. We focus our attention on molecules NH3, NO, NO2, and CO, which provide additional states permitted by the host electrons. Utilizing the six-band tight-binding model based on an inversion symmetry (between {a,e} and {b,d} atoms) and the Kubo formalism, we survey the anisotropic electronic dispersion and the optical multi-interband spectrum produced by molecule-boron coupling. We consider the highest possibilities for the position of molecules on the boron atoms. For molecules on {a,e} atoms, the inherent metallic phase of β12-borophene becomes electron-doped semiconducting, while for molecules on {b,d} and c atoms, the metallic phase remains unchanged. For molecules on {a,e} and {b,d} atoms, we observe a redshift (blueshift) optical spectrum for longitudinal/transverse (Hall) component, while for molecules on c atoms, we find a redshift (blueshift) optical spectrum for longitudinal (transverse/Hall) component. We expect that this study provides useful information for engineering field-effect transistor-based gas sensors.
Collapse
Affiliation(s)
- Nguyen N Hieu
- Institute of Research and Development, Duy Tan University, Da Nang, 550000, Vietnam
- Faculty of Natural Sciences, Duy Tan University, Da Nang, 550000, Vietnam
| | - Chuong V Nguyen
- Department of Materials Science and Engineering, Le Quy Don Technical University, Ha Noi, 100000, Vietnam
| | - Huynh V Phuc
- Division of Theoretical Physics, Dong Thap University, Cao Lanh, 870000, Vietnam
| | - Bui D Hoi
- Faculty of Physics, University of Education, Hue University, Hue, 530000, Vietnam.
| |
Collapse
|
4
|
de-la-Huerta-Sainz S, Ballesteros A, Cordero NA. Gaussian Curvature Effects on Graphene Quantum Dots. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 13:95. [PMID: 36616005 PMCID: PMC9824217 DOI: 10.3390/nano13010095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/20/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
In the last few years, much attention has been paid to the exotic properties that graphene nanostructures exhibit, especially those emerging upon deforming the material. Here we present a study of the mechanical and electronic properties of bent hexagonal graphene quantum dots employing density functional theory. We explore three different kinds of surfaces with Gaussian curvature exhibiting different shapes-spherical, cylindrical, and one-sheet hyperboloid-used to bend the material, and several boundary conditions regarding what atoms are forced to lay on the chosen surface. In each case, we study the curvature energy and two quantum regeneration times (classic and revival) for different values of the curvature radius. A strong correlation between Gaussian curvature and these regeneration times is found, and a special divergence is observed for the revival time for the hyperboloid case, probably related to the pseudo-magnetic field generated by this curvature being capable of causing a phase transition.
Collapse
Affiliation(s)
| | | | - Nicolás A. Cordero
- Physics Department, Universidad de Burgos, E-09001 Burgos, Spain
- International Research Center in Critical Raw Materials for Advanced Industrial Technologies (ICCRAM), Unversidad de Burgos, E-09001 Burgos, Spain
- Institute Carlos I for Theoretical and Computational Physics (IC1), E-18016 Granada, Spain
| |
Collapse
|
5
|
Reza Zaimbashi, Hadi Beitollahi. Electrochemical Sensor for Detection of Hydrochlorothiazide Based on Screen-Printed Electrode Modified with ZnO/Al2O3 Nanocomposite. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY 2022. [DOI: 10.3103/s1068375522060163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
6
|
Xia Z, Zhou Y, Gong Y, Mao P, Zhang N, Yuan C, Xue W. AuNPs and graphdiyne nanocomposite as robust electrocatalyst for methyl parathion detection in real samples. ANAL SCI 2022; 38:1513-1522. [PMID: 36071334 DOI: 10.1007/s44211-022-00184-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 08/23/2022] [Indexed: 11/28/2022]
Abstract
The present work describes a simple and rapid synthesis method of gold nanoparticles and graphdiyne (AuNPs@GDY) nanocomposites including porous structure. Moreover, the synthesized AuNPs@GDY material was decorated on the glassy carbon electrode (GCE) with a drop coating method to construct a non-enzymatic electrochemical pesticides sensor. The micro-morphology and elemental composition of the materials were characterized by transmission electron microscopy (TEM) and energy dispersive spectroscopy (EDS). The electrocatalysis and conductivity of the material were studied with cyclic voltammetry (CV) and impedance method, respectively. The properties of the sensor were investigated by CV and differential pulse voltammetry (DPV). The results showed that AuNPs@GDY exhibited excellent electrocatalytic ability for methyl parathion in a wide linear range (from 0.25 ng/mL to 24.43 μg/mL) and low limit of detection value (6.2 pg/mL). Furthermore, the DPV method used in this paper was accurate and sensitive, and could be used for routine quality control of methyl parathion in kiwi fruit and tomato samples.
Collapse
Affiliation(s)
- Zhi Xia
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
- College of Chemistry and Chemical Engineering, Guizhou University of Engineering Science, Bijie, 551700, People's Republic of China
| | - Yuanxiang Zhou
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
| | - Yuchen Gong
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
| | - Piao Mao
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
| | - Nian Zhang
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
| | - Chunmei Yuan
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China
| | - Wei Xue
- Key Laboratory of Green Pesticide and Agricultural Bioengineering, Ministry of Education, Research and Development Center for Fine Chemicals, Guizhou University, Guiyang, 550025, People's Republic of China.
| |
Collapse
|
7
|
Recent Advances in Electrochemical Sensing of Hydrogen Peroxide (H 2O 2) Released from Cancer Cells. NANOMATERIALS 2022; 12:nano12091475. [PMID: 35564184 PMCID: PMC9103167 DOI: 10.3390/nano12091475] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/22/2022] [Accepted: 03/23/2022] [Indexed: 12/26/2022]
Abstract
Cancer is by far the most common cause of death worldwide. There are more than 200 types of cancer known hitherto depending upon the origin and type. Early diagnosis of cancer provides better disease prognosis and the best chance for a cure. This fact prompts world-leading scientists and clinicians to develop techniques for the early detection of cancer. Thus, less morbidity and lower mortality rates are envisioned. The latest advancements in the diagnosis of cancer utilizing nanotechnology have manifested encouraging results. Cancerous cells are well known for their substantial amounts of hydrogen peroxide (H2O2). The common methods for the detection of H2O2 include colorimetry, titration, chromatography, spectrophotometry, fluorimetry, and chemiluminescence. These methods commonly lack selectivity, sensitivity, and reproducibility and have prolonged analytical time. New biosensors are reported to circumvent these obstacles. The production of detectable amounts of H2O2 by cancerous cells has promoted the use of bio- and electrochemical sensors because of their high sensitivity, selectivity, robustness, and miniaturized point-of-care cancer diagnostics. Thus, this review will emphasize the principles, analytical parameters, advantages, and disadvantages of the latest electrochemical biosensors in the detection of H2O2. It will provide a summary of the latest technological advancements of biosensors based on potentiometric, impedimetric, amperometric, and voltammetric H2O2 detection. Moreover, it will critically describe the classification of biosensors based on the material, nature, conjugation, and carbon-nanocomposite electrodes for rapid and effective detection of H2O2, which can be useful in the early detection of cancerous cells.
Collapse
|
8
|
Liang Y, Xu Y, Tong Y, Chen Y, Chen X, Wu S. Graphene-Based Electrochemical Sensor for Detection of Hepatocellular Carcinoma Markers. Front Chem 2022; 10:883627. [PMID: 35464224 PMCID: PMC9024117 DOI: 10.3389/fchem.2022.883627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 03/09/2022] [Indexed: 11/23/2022] Open
Abstract
Hepatocellular carcinoma (HCC) is a group of highly lethal malignant tumors that seriously threaten human health. The main way to improve the survival quality and reduce the mortality of HCC is early diagnosis and treatment. Therefore, it will be of great significance to explore new quantitative detection methods for HCC markers. With the rapid development of electrochemical biosensors and nanomaterials, electrochemical sensors based on graphene can detect tumor markers, with the advantages of simple operation, high detection sensitivity, and specificity. Combined with the published literature in recent years, the article briefly reviews the application of graphene-based electrochemical biosensors in the detection of HCC markers, including alpha-fetoprotein (AFP), Golgi protein-73 (GP73), exosomes, and microRNA-122 (miR-122).
Collapse
Affiliation(s)
- Ying Liang
- Center for Clinical Laboratory, General Hospital of the Yangtze River Shipping, Wuhan Brain Hospital, Wuhan, China
| | - Yuan Xu
- Center for Clinical Laboratory, Wuhan Hospital of Chinese Medicine, Wuhan, China
| | - Yaoyao Tong
- Center for Clinical Laboratory, General Hospital of the Yangtze River Shipping, Wuhan Brain Hospital, Wuhan, China
| | - Yue Chen
- Center for Clinical Laboratory, General Hospital of the Yangtze River Shipping, Wuhan Brain Hospital, Wuhan, China
| | - Xilu Chen
- Center for Clinical Laboratory, General Hospital of the Yangtze River Shipping, Wuhan Brain Hospital, Wuhan, China
| | - Shimin Wu
- Center for Clinical Laboratory, General Hospital of the Yangtze River Shipping, Wuhan Brain Hospital, Wuhan, China
- *Correspondence: Shimin Wu,
| |
Collapse
|
9
|
Wu B, Xu H, Shi Y, Yao Z, Yu J, Zhou H, Li Y, Chen Q, Long Y. Microelectrode glucose biosensor based on nanoporous platinum/graphene oxide nanostructure for rapid glucose detection of tomato and cucumber fruits. FOOD QUALITY AND SAFETY 2022. [DOI: 10.1093/fqsafe/fyab030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Microelectrode glucose biosensor based on three-dimensional hybrid nanoporous platinum/graphene oxide nanostructure was developed for rapid glucose detection of tomato and cucumber fruits. The nanostructure was fabricated by a two-step modification method on microelectrode for loading a larger amount of glucose oxidase. The nanoporous structure was prepared on the surface of the platinum microelectrode by electrochemical etching, and then graphene oxide was deposited on the prepared nanoporous electrode by electrochemical deposition. The nanoprorous platinum/graphene oxide nanostructure had the advantage of improving the effective surface area of the electrode and the loading quantity of glucose oxidase. As a result, the biosensor achieved a wide range of 0.1-20.0 mM in glucose detection, which had the ability to accurately detect the glucose content. It was found that the three-dimensional hybrid nanostructure on the electrode surface realized the rapid direct electrochemistry of glucose oxidase. Therefore, the biosensor achieved high glucose detection sensitivity (11.64 μA mM -1cm -2), low detection limit (13 μM) and rapid response time (reaching 95% steady-state response within 3 seconds), when calibrating in glucose standard solution. In agricultural application, the as-prepared biosensor was employed to detect the glucose concentration of tomato and cucumber samples. The results showed that the relative deviation of this method was less than 5% when compared with that of HPLC, implying high accuracy of the presented biosensor in glucose detection in plants.
Collapse
|
10
|
Functionalization of Screen-Printed Sensors with a High Reactivity Carbonaceous Material for Ascorbic Acid Detection in Fresh-Cut Fruit with Low Vitamin C Content. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9120354] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, carbon screen-printed sensors (C-SPEs) were functionalized with a high reactivity carbonaceous material (HRCM) to measure the ascorbic acid (AA) concentration in fresh-cut fruit (i.e., watermelon and apple) with a low content of vitamin C. HRCM and the functionalized working electrodes (WEs) were characterized by SEM and TEM. The increases in the electroactive area and in the diffusion of AA molecules towards the WE surface were evaluated by cyclic voltammetry (CV) and chronoamperometry. The performance of HRCM-SPEs were evaluated by CV and constant potential amperometry compared with the non-functionalized C-SPEs and MW-SPEs nanostructured with multi-walled carbon nanotubes. The results indicated that SPEs functionalized with 5 mg/mL of HRCM and 10 mg/mL of MWCNTs had the best performances. HRCM and MWCNTs increased the electroactive area by 1.2 and 1.4 times, respectively, whereas, after functionalization, the AA diffusion rate towards the electrode surface increased by an order of 10. The calibration slopes of HRCM and MWCNTs improved from 1.9 to 3.7 times, thus reducing the LOD of C-SPE from 0.55 to 0.15 and 0.28 μM, respectively. Finally, the functionalization of the SPEs proved to be indispensable for determining the AA concentration in the watermelon and apple samples.
Collapse
|
11
|
Preparation and electrochemical sensor application of tetra aniline/graphene oxide/gold nanoparticle composites`. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
12
|
Del Real Mata C, Siavash Moakhar R, Hosseini II, Jalali M, Mahshid S. A nanostructured microfluidic device for plasmon-assisted electrochemical detection of hydrogen peroxide released from cancer cells. NANOSCALE 2021; 13:14316-14329. [PMID: 34477715 DOI: 10.1039/d0nr07608b] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Non-invasive liquid biopsies offer hope for a rapid, risk-free, real-time glimpse into cancer diagnostics. Recently, hydrogen peroxide (H2O2) was identified as a cancer biomarker due to its continued release from cancer cells compared to normal cells. The precise monitoring and quantification of H2O2 are hindered by its low concentration and the limit of detection (LOD) in traditional sensing methods. Plasmon-assisted electrochemical sensors with their high sensitivity and low LOD make a suitable candidate for effective detection of H2O2, yet their electrical properties need to be improved. Here, we propose a new nanostructured microfluidic device for ultrasensitive, quantitative detection of H2O2 released from cancer cells in a portable fashion. The fluidic device features a series of self-organized gold nanocavities, enhanced with graphene nanosheets having optoelectrical properties, which facilitate the plasmon-assisted electrochemical detection of H2O2 released from human cells. Remarkably, the device can successfully measure the released H2O2 from breast cancer (MCF-7) and prostate cancer (PC3) cells in human plasma. Briefly, direct amperometric detection of H2O2 under simulated visible light illumination showed a superb LOD of 1 pM in a linear range of 1 pM-10 μM. We thoroughly studied the formation of self-organized plasmonic nanocavities on gold electrodes via surface and photo-electrochemical characterization techniques. In addition, the finite-difference time domain (FDTD) simulation of the electric field demonstrates the intensity of charge distribution at the nanocavity structure edges under visible light illumination. The superb LOD of the proposed electrode combining gold plasmonic nanocavities and graphene sheets paves the way for the development of non-invasive plasmon-assisted electrochemical sensors that can effectively detect low concentrations of H2O2 released from cancer cells.
Collapse
|
13
|
Ming Y, Yu Y, Yang CL, Chen XM, Han RX, Hao Y, Hu DR, Pan M, Zhou XH, Qian ZY. Rapid Electrochemical Screening of Phenylketonuria Maker Depending on Dehydrogenase Attached to the Pt-Doped Reduced Graphene Oxide Nanocomposites. J Biomed Nanotechnol 2021; 17:921-931. [PMID: 34082877 DOI: 10.1166/jbn.2021.3067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Phenylketonuria (PKU) is a common disease associated with amino acid metabolism, and usually occurs in newborns. It can cause serious neurological diseases and even death. However, owing to inadequate-effective treatment, it can only be slowed by a low-phenylalanine (Phe) diet. In addition, PKU screening is essential for newborns in many countries. Therefore, rapid screening is crucial for preventing damage and meeting the large sample diagnosis demand. For confirmed patients, a convenient method to monitor their regular Phe levels is required. However, current clinical methods do not meet the rapid screening and convenient monitoring requirements. Herein, a rapid and facile electrochemical device based on platinum-doped reduced graphene oxide nanocomposites was developed to detect PKU biomarker-Phe. The results demonstrated that the developed electrode has great sensitivity, selectivity, and stability. The detection range was 0.0001 mM to 6 mM with a limit of detection of 0.01 μM. Therefore, this work offers a simple and rapid method for point-of-care PKU screening and daily monitoring.
Collapse
Affiliation(s)
- Yang Ming
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Yan Yu
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Cheng-Li Yang
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Xin-Mian Chen
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Ru-Xia Han
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Ying Hao
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Dan-Rong Hu
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Meng Pan
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Xiao-Han Zhou
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Zhi-Yong Qian
- The State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
| |
Collapse
|
14
|
Cao P, Wang N, Dai H, Ma H, Lin M. Molybdenum-containing polypyrrole self-supporting hollow flexible electrode for hydrogen peroxide detection in living cells. Anal Chim Acta 2021; 1151:338251. [PMID: 33608079 DOI: 10.1016/j.aca.2021.338251] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Revised: 01/18/2021] [Accepted: 01/22/2021] [Indexed: 10/22/2022]
Abstract
A flexible electrode based on polypyrrole-supported free-standing molybdenum oxide-molybdenum disulfide/polypyrrole nanostructure (MoO3-MoS2/PPy) was synthesized. The petal-like MoO3-MoS2 sheets grown on PPy were prepared step by step through simple electrodeposition and hydrothermal methods. The corresponding surface morphological and structural characterizations were characterized by field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The results showed that the prepared petal MoO3-MoS2 hybrid nanomaterials were uniformly distributed on the PPy skeleton and exhibited a three-dimensional porous network structure. The flexible electrode was used for non-enzymatic detection of hydrogen peroxide (H2O2), and the developed MoO3-MoS2/PPy nanomaterials exhibited high electrochemical sensing performance in the range of 0.3-150 μM, with the detection limit of 0.18 μM (S/N = 3). The excellent detection properties enabled the MoO3-MoS2/PPy flexible electrode to detect H2O2 released by living cells. The resulting MoO3-MoS2/PPy flexible electrode also has the advantages of customizable shape and adjustability, which provides a potential platform for constructing clinically diagnosed in vivo portable instruments and real-time environmental monitoring.
Collapse
Affiliation(s)
- Pengfei Cao
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, China
| | - Nan Wang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, China
| | - Hongxiu Dai
- Department Chemistry, Liaocheng University, Liaocheng, 252059, China
| | - Houyi Ma
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, China
| | - Meng Lin
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, China.
| |
Collapse
|
15
|
Au doped poly-thionine and poly-m-Cresol purple: Synthesis and their application in simultaneously electrochemical detection of two lung cancer markers CEA and CYFRA21-1. Talanta 2021; 224:121816. [DOI: 10.1016/j.talanta.2020.121816] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 10/20/2020] [Accepted: 10/23/2020] [Indexed: 12/27/2022]
|
16
|
Nemčeková K, Labuda J. Advanced materials-integrated electrochemical sensors as promising medical diagnostics tools: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 120:111751. [PMID: 33545892 DOI: 10.1016/j.msec.2020.111751] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/13/2020] [Accepted: 11/21/2020] [Indexed: 02/08/2023]
Abstract
Electrochemical sensors have increasingly been linked with terms as modern biomedically effective highly selective and sensitive devices, wearable and wireless technology, portable electronics, smart textiles, energy storage, communication and user-friendly operating systems. The work brings the overview of the current advanced materials and their application strategies for improving performance, miniaturization and portability of sensing devices. It provides the extensive information on recently developed (bio)sensing platforms based on voltammetric, amperometric, potentiometric and impedimetric detection modes including portable, non-invasive, wireless, and self-driven miniaturized devices for monitoring human and animal health. Diagnostics of selected free radical precursors, low molecular biomarkers, nucleic acids and protein-based biomarkers, bacteria and viruses of today's interest is demonstrated.
Collapse
Affiliation(s)
- Katarína Nemčeková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| | - Ján Labuda
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| |
Collapse
|
17
|
Cogal S. A review of poly(3,4-ethylenedioxythiophene) and its composites-based electrochemical sensors for dopamine detection. POLYM-PLAST TECH MAT 2020. [DOI: 10.1080/25740881.2020.1811321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Sadik Cogal
- Department of Polymer Engineering, Faculty of Engineering and Architecture, Burdur Mehmet Akif Ersoy University, Burdur, Turkey
| |
Collapse
|
18
|
A Brief Description of Cyclic Voltammetry Transducer-Based Non-Enzymatic Glucose Biosensor Using Synthesized Graphene Electrodes. APPLIED SYSTEM INNOVATION 2020. [DOI: 10.3390/asi3030032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The essential disadvantages of conventional glucose enzymatic biosensors such as high fabrication cost, poor stability of enzymes, pH value-dependent, and dedicated limitations, have been increasing the attraction of non-enzymatic glucose sensors research. Beneficially, patients with diabetes could use this type of sensor as a fourth-generation of glucose sensors with a very low cost and high performance. We demonstrate the most common acceptable transducer for a non-enzymatic glucose biosensor with a brief description of how it works. The review describes the utilization of graphene and its composites as new materials for high-performance non-enzymatic glucose biosensors. The electrochemical properties of graphene and the electrochemical characterization using the cyclic voltammetry (CV) technique of electrocatalysis electrodes towards glucose oxidation have been summarized. A recent synthesis method of the graphene-based electrodes for non-enzymatic glucose sensors have been introduced along with this study. Finally, the electrochemical properties such as linearity, sensitivity, and the limit of detection (LOD) for each sensor are introduced with a comparison with each other to figure out their strengths and weaknesses.
Collapse
|
19
|
Shu Q, Liao F, Hong N, Cheng L, Lin Y, Cui H, Su J, Ma G, Wei G, Zhong Y, Xiong J, Fan H. A novel DNA sensor of homogeneous electrochemical signal amplification strategy. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104777] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
20
|
Lebioda M, Pawlak R, Szymański W, Kaczorowski W, Jeziorna A. Laser Patterning a Graphene Layer on a Ceramic Substrate for Sensor Applications. SENSORS 2020; 20:s20072134. [PMID: 32290089 PMCID: PMC7181160 DOI: 10.3390/s20072134] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 04/03/2020] [Accepted: 04/07/2020] [Indexed: 02/07/2023]
Abstract
This paper describes a method for patterning the graphene layer and gold electrodes on a ceramic substrate using a Nd:YAG nanosecond fiber laser. The technique enables the processing of both layers and trimming of the sensor parameters. The main aim was to develop a technique for the effective and efficient shaping of both the sensory layer and the metallic electrodes. The laser shaping method is characterized by high speed and very good shape mapping, regardless of the complexity of the processing. Importantly, the technique enables the simultaneous shaping of both the graphene layer and Au electrodes in a direct process that does not require a complex and expensive masking process, and without damaging the ceramic substrate. Our results confirmed the effectiveness of the developed laser technology for shaping a graphene layer and Au electrodes. The ceramic substrate can be used in the construction of various types of sensors operating in a wide temperature range, especially the cryogenic range.
Collapse
Affiliation(s)
- Marcin Lebioda
- Institute of Electrical Engineering Systems, Lodz University of Technology, 90-924 Lodz, Poland;
- Correspondence: ; Tel.: +48-426-312-537
| | - Ryszard Pawlak
- Institute of Electrical Engineering Systems, Lodz University of Technology, 90-924 Lodz, Poland;
| | - Witold Szymański
- Institute of Materials Science and Engineering, Lodz University of Technology, 90-924 Lodz, Poland; (W.S.); (W.K.); (A.J.)
| | - Witold Kaczorowski
- Institute of Materials Science and Engineering, Lodz University of Technology, 90-924 Lodz, Poland; (W.S.); (W.K.); (A.J.)
| | - Agata Jeziorna
- Institute of Materials Science and Engineering, Lodz University of Technology, 90-924 Lodz, Poland; (W.S.); (W.K.); (A.J.)
| |
Collapse
|
21
|
Yu C, Shen W, Yan J, Zhong M, Zhang J, Li L, Hao Q, Gao F, Tian Y, Huang Y. Growing large-area multilayer graphene sheets on molten cerium via anthracite as carbon source. INORG CHEM COMMUN 2020. [DOI: 10.1016/j.inoche.2019.107729] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
22
|
Abstract
Chymotrypsin is one of the most extensively known proteases participating in the pathogenesis of various diseases, which can be used in drug discovery and clinical diagnosis.
Collapse
Affiliation(s)
- Haixia Shi
- P. E. Department
- Jiangsu University
- Zhenjiang 212013
- P. R. China
| | - Cheng Liu
- School of Life Sciences
- Jiangsu University
- Zhenjiang 212013
- P. R. China
| | - Jingjie Cui
- School of Automation
- Hangzhou Dianzi University
- Hangzhou
- P. R. China
| | - Jia Cheng
- School of Life Sciences
- Jiangsu University
- Zhenjiang 212013
- P. R. China
| | - Yuanwei Lin
- School of Life Sciences
- Jiangsu University
- Zhenjiang 212013
- P. R. China
| | - Li Gao
- School of Life Sciences
- Jiangsu University
- Zhenjiang 212013
- P. R. China
| | - Rong Luo
- Institute of Geriatric Cardiovascular Disease
- Chengdu Medical College
- Chengdu
- China
| |
Collapse
|
23
|
Ratnam KV, Manjunatha H, Janardan S, Babu Naidu KC, Ramesh S. Nonenzymatic electrochemical sensor based on metal oxide, MO (M= Cu, Ni, Zn, and Fe) nanomaterials for neurotransmitters: An abridged review. SENSORS INTERNATIONAL 2020. [DOI: 10.1016/j.sintl.2020.100047] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
|
24
|
Zhu M, Li R, Lai M, Ye H, Long N, Ye J, Wang J. Copper nanoparticles incorporating a cationic surfactant-graphene modified carbon paste electrode for the simultaneous determination of gatifloxacin and pefloxacin. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2019.113730] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
25
|
Xiao F, Li H, Yan X, Yan L, Zhang X, Wang M, Qian C, Wang Y. Graphitic carbon nitride/graphene oxide(g-C 3N 4/GO) nanocomposites covalently linked with ferrocene containing dendrimer for ultrasensitive detection of pesticide. Anal Chim Acta 2019; 1103:84-96. [PMID: 32081192 DOI: 10.1016/j.aca.2019.12.066] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 12/18/2019] [Accepted: 12/23/2019] [Indexed: 12/23/2022]
Abstract
We report herein the design of a novel electrochemical sensing strategy for sensitive detection of pesticide based on graphitic carbon nitride (g-C3N4)/graphene oxide(GO) nanocomposite covalently bound to a ferrocene containing dendrimer(Fc-TED). The g-C3N4 with sufficient N atoms for providing lone pairs of electrons to an electron acceptor so as to enhance the adsorption towards organic molecules. The Fc-TED dendrimers with the native redox signaling center (Fe3+/Fe2+) can increase the electron transition of g-C3N4 from valence to conduction band. While GO can accelerate the electron transfer from g-C3N4 surface and Fc-TED to glassy carbon electrode(GCE), which would amplify the electrochemical signal of g-C3N4/GO/Fc-TED/GCE sensor and then improve the sensing performance. It is found that the fabricated electrode demonstrated an admirable electrochemical sensing performance towards metolcarb in terms of low detection limit (8.3 nM), wide concentration range (0.045-213 μM) and rapid response time (2s). The proposed sensor can selectively detect the metolcarb and easily discriminated metolcarb from the possible interfering species. The practical applicability of the sensor was successfully evaluated in real vegetable sample and achieved satisfactory recoveries with good precision and accuracy.
Collapse
Affiliation(s)
- Fengjuan Xiao
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China.
| | - Hongli Li
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Xinrui Yan
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Lu Yan
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Xuefei Zhang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Meng Wang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Cheng Qian
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Yiqi Wang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| |
Collapse
|
26
|
Zheng H, Yan Z, Wang M, Chen J, Zhang X. Biosensor based on polyaniline-polyacrylonitrile-graphene hybrid assemblies for the determination of phenolic compounds in water samples. JOURNAL OF HAZARDOUS MATERIALS 2019; 378:120714. [PMID: 31203123 DOI: 10.1016/j.jhazmat.2019.05.107] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 05/17/2019] [Accepted: 05/30/2019] [Indexed: 05/23/2023]
Abstract
Phenolic compounds are major environmental pollutants due to their toxic and hazardous nature on human health. A fast, sensitive and stable sensor for determination of phenolic compounds in the environmental water remains challenging. Herein, a biosensor platform with stable response current was fabricated by entrapment of polyphenol oxidase (PPO) into hybrid assemblies of the conducting polyaniline (PAni)-porous polyacrylonitrile (Pan)-nanostructured graphene (GRA) and phase inversion process. The porous structure of Pan provided a favorable microenvironment for easily binding to PAni and GRA to obtain hybrid assemblies for effective immobilization of enzyme and increased synergistic effect. The morphologies and the electrochemical behaviors of the as-prepared biosensor were investigated using scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), respectively. The proposed biosensor showed excellent sensitivity (6.46 μA μM-1 cm-2) and fast response time (˜5 s) with low detection limit (2.65×10-7 M) under the optimal pH value and applied potential. The biosensor was highly selective towards p-cresol that almost no signal was detected from common interferents. The biosensor was used for determination of phenolic compounds in water samples with satisfactory results compared with that of UPLC, demonstrating its great potential as a biosensor for the rapid determination of phenolic pollutants.
Collapse
Affiliation(s)
- Hao Zheng
- Institute of Marine Chemistry and Environment, Ocean College, Zhejiang University, Zhoushan, 316021, PR China.
| | - Zupeng Yan
- Institute of Marine Chemistry and Environment, Ocean College, Zhejiang University, Zhoushan, 316021, PR China
| | - Minghui Wang
- Institute of Marine Chemistry and Environment, Ocean College, Zhejiang University, Zhoushan, 316021, PR China
| | - Jianfang Chen
- Institute of Marine Chemistry and Environment, Ocean College, Zhejiang University, Zhoushan, 316021, PR China; Key Laboratory of Marine Ecosystems and Biogeochemistry, Second Institute of Oceanography, Ministry of Natural Resources, Hangzhou, 310012, PR China
| | - Xinzheng Zhang
- Institute of Marine Chemistry and Environment, Ocean College, Zhejiang University, Zhoushan, 316021, PR China
| |
Collapse
|
27
|
Kong FY, Li RF, Yao L, Wang ZX, Li HY, Wang WJ, Wang W. A novel electrochemical sensor based on Au nanoparticles/8-aminoquinoline functionalized graphene oxide nanocomposite for paraquat detection. NANOTECHNOLOGY 2019; 30:285502. [PMID: 30884476 DOI: 10.1088/1361-6528/ab10ac] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In this paper, a novel electrochemical sensor based on Au nanoparticles/8-aminoquinoline functionalized graphene oxide (AuNPs/GAQ) nanocomposite was developed and tested for the first time for detection of paraquat (PQ). The morphology and composition of AuNPs/GAQ nanocomposite were characterized by various techniques, including transmission electron microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, and x-ray photoelectron spectroscopy. Cyclic voltammetry and differential pulse voltammetry were utilized to investigate the electrochemical performances of AuNPs/GAQ nanocomposite modified glassy carbon electrode. The obtained modified electrode exhibited excellent electrocatalytic activity towards detection of PQ. Under the optimized conditions, the proposed sensor showed low detection limit (6 nM, S/N = 3), wide linear range (0.02-24 μM), high selectivity and good stability. In addition, it was successfully applied for detection of PQ in natural water samples with satisfactory results.
Collapse
Affiliation(s)
- Fen-Ying Kong
- School of Chemistry and Chemical Engineering, Yancheng Institute of Technology, Yancheng 224051, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|
28
|
Jing MH, Song XM, Fang DW, Zhang L, Zhang Q. Construction of multifunctional electrochemical sensor based on electroactivity-adjustable poly (ionic liquids)/reduced graphene oxide. Talanta 2019; 197:277-283. [PMID: 30771935 DOI: 10.1016/j.talanta.2018.12.101] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Revised: 12/05/2018] [Accepted: 12/31/2018] [Indexed: 11/28/2022]
Abstract
In this article, a novel electroactivity-adjustable poly (ionic liquids)/reduced graphene oxide (PIL-GP) was developed and utilized for the fabrication of multifunctional, high stable electrochemical sensors. The structure, morphology and surface charge properties of PIL-GP have been systematically studied. And the selective detection performance of dopamine (DA) on PIL-GP modified glassy carbon electrode (GCE) were further explored by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). More importantly, by virtue of the anion exchange property of PIL, electroactive Fe(CN)63-/PIL-GP/GCE and Polyoxometalates (PWA)/PIL-GP/GCE were easily fabricated and their electrochemical detection performance of ascorbic acid (AA) and bromate were investigated respectively. The results showed that PIL-GP/GCE based electrochemical sensors provided higher sensitivity, lower detection limits and outstanding anti-interference ability in certain detection system. It was indicated that this general approach to construct electroactivity-adjustable sensors with various electroactive anions possessed a broad application prospect.
Collapse
Affiliation(s)
- Ming-Hua Jing
- College of Chemistry, Liaoning University, Shenyang 110036, China; Institute of Rare and Scattered Elements, College of Chemistry, Liaoning University, Shenyang 110036, China
| | - Xi-Ming Song
- College of Chemistry, Liaoning University, Shenyang 110036, China
| | - Da-Wei Fang
- College of Chemistry, Liaoning University, Shenyang 110036, China; Institute of Rare and Scattered Elements, College of Chemistry, Liaoning University, Shenyang 110036, China
| | - Ling Zhang
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, China.
| | - Qian Zhang
- College of Chemistry, Liaoning University, Shenyang 110036, China.
| |
Collapse
|
29
|
Point-of-care rapid detection of Vibrio parahaemolyticus in seafood using loop-mediated isothermal amplification and graphene-based screen-printed electrochemical sensor. Biosens Bioelectron 2019; 132:271-278. [DOI: 10.1016/j.bios.2019.02.060] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Accepted: 02/21/2019] [Indexed: 12/18/2022]
|
30
|
Lee JH, Park SJ, Choi JW. Electrical Property of Graphene and Its Application to Electrochemical Biosensing. NANOMATERIALS 2019; 9:nano9020297. [PMID: 30791566 PMCID: PMC6409852 DOI: 10.3390/nano9020297] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 02/13/2019] [Accepted: 02/18/2019] [Indexed: 12/27/2022]
Abstract
Graphene, a single atom thick layer of two-dimensional closely packed honeycomb carbon lattice, and its derivatives have attracted much attention in the field of biomedical, due to its unique physicochemical properties. The valuable physicochemical properties, such as high surface area, excellent electrical conductivity, remarkable biocompatibility and ease of surface functionalization have shown great potentials in the applications of graphene-based bioelectronics devices, including electrochemical biosensors for biomarker analysis. In this review, we will provide a selective overview of recent advances on synthesis methods of graphene and its derivatives, as well as its application to electrochemical biosensor development. We believe the topics discussed here are useful, and able to provide a guideline in the development of novel graphene and on graphene-like 2-dimensional (2D) materials based biosensors in the future.
Collapse
Affiliation(s)
- Jin-Ho Lee
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea.
- Department of Chemistry and Chemical Biology, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA.
| | - Soo-Jeong Park
- Research Center for Disease Biophysics of Sogang-Harvard, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea.
| | - Jeong-Woo Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea.
- Research Center for Disease Biophysics of Sogang-Harvard, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea.
| |
Collapse
|
31
|
Jin Q, Chen HJ, Li X, Huang X, Wu Q, He G, Hang T, Yang C, Jiang Z, Li E, Zhang A, Lin Z, Liu F, Xie X. Reduced Graphene Oxide Nanohybrid-Assembled Microneedles as Mini-Invasive Electrodes for Real-Time Transdermal Biosensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1804298. [PMID: 30605244 DOI: 10.1002/smll.201804298] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 12/14/2018] [Indexed: 06/09/2023]
Abstract
A variety of nanomaterial-based biosensors have been developed to sensitively detect biomolecules in vitro, yet limited success has been achieved in real-time sensing in vivo. The application of microneedles (MN) may offer a solution for painless and minimally-invasive transdermal biosensing. However, integration of nanostructural materials on microneedle surface as transdermal electrodes remains challenging in applications. Here, a transdermal H2 O2 electrochemical biosensor based on MNs integrated with nanohybrid consisting of reduced graphene oxide and Pt nanoparticles (Pt/rGO) is developed. The Pt/rGO significantly improves the detection sensitivity of the MN electrode, while the MNs are utilized as a painless transdermal tool to access the in vivo environment. The Pt/rGO nanostructures are protected by a water-soluble polymer layer to avoid mechanical destruction during the MN skin insertion process. The polymer layer can readily be dissolved by the interstitial fluid and exposes the Pt/rGO on MNs for biosensing in vivo. The applications of the Pt/rGO-integrated MNs for in situ and real-time sensing of H2 O2 in vivo are demonstrated both on pigskin and living mice. This work offers a unique real-time transdermal biosensing system, which is a promising tool for sensing in vivo with high sensitivity but in a minimally-invasive manner.
Collapse
Affiliation(s)
- Quanchang Jin
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Hui-Jiuan Chen
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Xiangling Li
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Xinshuo Huang
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Qianni Wu
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Gen He
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Tian Hang
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Chengduan Yang
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Zhen Jiang
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Enlai Li
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Aihua Zhang
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Zhihong Lin
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Fanmao Liu
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| | - Xi Xie
- The First Affiliated Hospital of Sun Yat-sen University, State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, 510000, Guangzhou, China
| |
Collapse
|
32
|
Construction of a Biosensor Based on a Combination of Cytochrome c, Graphene, and Gold Nanoparticles. SENSORS 2018; 19:s19010040. [PMID: 30583520 PMCID: PMC6339241 DOI: 10.3390/s19010040] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 12/17/2018] [Accepted: 12/19/2018] [Indexed: 02/04/2023]
Abstract
A biosensor based on a combination of cytochrome c (Cyt c), electrochemical reduced graphene oxides (ERGO), and gold nanoparticles (AuNPs) on a glassy carbon electrode (GCE) was fabricated. The proposed biosensor electrode was denoted as GCE/ERGO-Nafion/AuNPs/Cyt c/Nafion, where ERGO-Nafion was deposited by dropping graphene oxides-Nafion mixed droplet first and following electrochemical reduction, AuNPs were directly deposited on the surface of the ERGO-Nafion modified electrode by electrochemical reduction, and other components were deposited by the dropping-dry method. The effect of the deposition amount of AuNPs on direct electrochemistry of Cyt c in the proposed electrode was investigated. The hydrogen peroxide was taken to evaluate the performance of the proposed biosensor. The results showed that the biosensor has great analytical performance, including a high sensitivity, a wide linear range, a low detection limit, and good stability, reproducibility, and reliability.
Collapse
|
33
|
Xiao F, Guo M, Wang J, Yan X, Li H, Qian C, Yu Y, Dai D. Ferrocene-terminated dendrimer functionalized graphene oxide layered sensor toward highly sensitive evaluation of Di(2-ethylhexyl) phthalate in liquor samples. Anal Chim Acta 2018; 1043:35-44. [DOI: 10.1016/j.aca.2018.08.046] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/22/2018] [Accepted: 08/24/2018] [Indexed: 12/18/2022]
|
34
|
Parnianchi F, Nazari M, Maleki J, Mohebi M. Combination of graphene and graphene oxide with metal and metal oxide nanoparticles in fabrication of electrochemical enzymatic biosensors. INTERNATIONAL NANO LETTERS 2018. [DOI: 10.1007/s40089-018-0253-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
35
|
Walsh KB, Li H, Koley G. Graphene alters the properties of voltage-gated Ca
2+
channels in rat cardiomyocytes. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aad0cd] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Zhang H, Zhang B, Chen A, Qin Y. Controllable n-Fe 2O 3@graphene nanomaterials by ALD applied in an aptasensor with enhanced electrochemical performance for thrombin detection. Dalton Trans 2018; 46:7434-7440. [PMID: 28548671 DOI: 10.1039/c7dt01184a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
An elegant atomic layer deposition (ALD) method has been employed for the controllable preparation of a uniform Fe2O3-coated graphene nanostructure (Fe2O3@graphene). The Fe2O3 coating thickness of the Fe2O3@graphene nanostructure can be tuned by varying the cycle number of Fe2O3 ALD. The produced Fe2O3@graphene composites are characterized by transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and cyclic voltammetry (CV). It is revealed that Fe2O3 is effectively deposited on the surface of graphene. Combined with the high affinity and specificity of an aptamer, a simple, rapid and sensitive electrochemical aptasensor was successfully fabricated for thrombin detection. The resulting electrochemical aptasensor displays a linear response to thrombin in the 1.0 × 10-11 to 4.0 × 10-9 M concentration range with the detection limit of 1.0 × 10-12 M (at an S/N of 3). The described controllable multifunctional graphene nanomaterials from ALD are expected to be applied in a biosensing platform which will exhibit wide applications in biological, medical, and environmental fields.
Collapse
Affiliation(s)
- Hongfen Zhang
- School of Pharmaceutical Science, Shanxi Medical University, Taiyuan 030001, China.
| | | | | | | |
Collapse
|
37
|
A new voltammetry sensor platform for eriocitrin based on CoS 2-MoS 2-PDDA-GR nanocomposite. Talanta 2018; 189:345-352. [PMID: 30086929 DOI: 10.1016/j.talanta.2018.07.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 06/22/2018] [Accepted: 07/01/2018] [Indexed: 12/14/2022]
Abstract
A novel electrochemically activated nanocomposite, CoS2 Nanoparticles and MoS2 Nanosheets decorated poly(diallyldimethylammonium chloride)-functionalized graphene (CoS2-MoS2-PDDA-GR), was successfully synthesized through a simple and low-cost method. X-ray diffraction (XRD), Transmission electron microscopy (TEM), Electrochemical impedance spectroscopy (EIS) and Cyclic voltammetry (CV) techniques were used to characterize the nanocomposites. Based on the CoS2-MoS2-PDDA-GR nanocomposite modified glassy carbon electrode, the electrochemical properties of eriocitrin were investigated in detail and a sensitive determinative method was established synchronously. Compared with others, this sensor exhibited larger effective surface area, more reactive site and excellent voltammetric response for eriocitrin. Under optimum conditions by DPV, the oxidation peak currents responded to eriocitrin linearly over a concentration range from 2.0 × 10-9 to 1.0 × 10-6 mol L-1 with a detection limit of 6.7 × 10-10 mol L-1 (S/N = 3). In addition, this fabricated sensor was successfully applied to detect eriocitrin in real samples with satisfactory results.
Collapse
|
38
|
Rahman MM, Hussein MA, Alamry KA, Al-Shehry FM, Asiri AM. Polyaniline/graphene/carbon nanotubes nanocomposites for sensing environmentally hazardous 4-aminophenol. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.nanoso.2017.08.006] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
39
|
Braga GB, Oliveira AEF, Pereira AC. Total Determination of Estrogenic Phenolic Compounds in River Water Using a Sensor Based on Reduced Graphene Oxide and Molecularly Imprinted Polymer. ELECTROANAL 2018. [DOI: 10.1002/elan.201800238] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Guilherme Bettio Braga
- Departamento de Ciências Naturais; Universidade Federal de São João del-Rei, UFSJ; São João del-Rei, mg 36307-352 Brazil
| | - Ana Elisa Ferreira Oliveira
- Departamento de Ciências Naturais; Universidade Federal de São João del-Rei, UFSJ; São João del-Rei, mg 36307-352 Brazil
| | - Arnaldo César Pereira
- Departamento de Ciências Naturais; Universidade Federal de São João del-Rei, UFSJ; São João del-Rei, mg 36307-352 Brazil
| |
Collapse
|
40
|
Facile synthesis of a SnO2@rGO nanohybrid and optimization of its methane-sensing parameters. Talanta 2018; 181:422-430. [DOI: 10.1016/j.talanta.2018.01.015] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2017] [Revised: 01/05/2018] [Accepted: 01/06/2018] [Indexed: 01/08/2023]
|
41
|
Tseng SC, Wu TY, Chou JC, Liao YH, Lai CH, Yan SJ, Tseng TW. Investigation of Sensitivities and Drift Effects of the Arrayed Flexible Chloride Sensor Based on RuO₂/GO at Different Temperatures. SENSORS 2018; 18:s18020632. [PMID: 29461506 PMCID: PMC5855318 DOI: 10.3390/s18020632] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 02/17/2018] [Accepted: 02/18/2018] [Indexed: 12/21/2022]
Abstract
We investigate the temperature effect on sensing characteristics and drift effect of an arrayed flexible ruthenium dioxide (RuO2)/graphene oxide (GO) chloride sensor at different solution temperatures between 10 °C and 50 °C. The average sensor sensitivities according to our experimental results were 28.2 ± 1.4 mV/pCl (10 °C), 42.5 ± 2.0 mV/pCl (20 °C), 47.1 ± 1.8 mV/pCl (30 °C), 54.1 ± 2.01 mV/pCl (40 °C) and 46.6 ± 2.1 mV/pCl (50 °C). We found the drift effects of an arrayed flexible RuO2/GO chloride sensor in a 1 M NaCl solution to be between 8.2 mV/h and 2.5 mV/h with solution temperatures from 10 °C to 50 °C.
Collapse
Affiliation(s)
- Shi-Chang Tseng
- Graduate School of Mechanical Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| | - Tong-Yu Wu
- Graduate School of Mechanical Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| | - Jung-Chuan Chou
- Department of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| | - Yi-Hung Liao
- Department of Information and Electronic Commerce Management, TransWorld University, Douliu 64002, Taiwan.
| | - Chih-Hsien Lai
- Department of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| | - Siao-Jie Yan
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| | - Ting-Wei Tseng
- Department of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan.
| |
Collapse
|
42
|
Chen F, Gao W, Qiu X, Zhang H, Liu L, Liao P, Fu W, Luo Y. Graphene quantum dots in biomedical applications: Recent advances and future challenges. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.flm.2017.12.006] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
43
|
An Electrochemical Enzyme Biosensor for 3-Hydroxybutyrate Detection Using Screen-Printed Electrodes Modified by Reduced Graphene Oxide and Thionine. BIOSENSORS-BASEL 2017; 7:bios7040050. [PMID: 29137135 PMCID: PMC5746773 DOI: 10.3390/bios7040050] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 11/08/2017] [Accepted: 11/10/2017] [Indexed: 01/01/2023]
Abstract
A biosensor for 3-hydroxybutyrate (3-HB) involving immobilization of the enzyme 3-hydroxybutyrate dehydrogenase onto a screen-printed carbon electrode modified with reduced graphene oxide (GO) and thionine (THI) is reported here. After addition of 3-hydroxybutyrate or the sample in the presence of NAD+ cofactor, the generated NADH could be detected amperometrically at 0.0 V vs. Ag pseudo reference electrode. Under the optimized experimental conditions, a calibration plot for 3-HB was constructed showing a wide linear range between 0.010 and 0.400 mM 3-HB which covers the clinically relevant levels for diluted serum samples. In addition, a limit of detection of 1.0 µM, much lower than that reported using other biosensors, was achieved. The analytical usefulness of the developed biosensor was demonstrated via application to spiked serum samples.
Collapse
|
44
|
Advances in sensing and biosensing of bisphenols: A review. Anal Chim Acta 2017; 998:1-27. [PMID: 29153082 DOI: 10.1016/j.aca.2017.09.048] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 09/22/2017] [Accepted: 09/23/2017] [Indexed: 12/19/2022]
Abstract
Bisphenols (BPs) are well known endocrine disrupting chemicals (EDCs) that cause adverse effects on the environment, biotic life and human health. BPs have been studied extensively because of an increasing concern for the safety of the environment and for human health. They are major raw materials for manufacturing polycarbonates, thermal papers and epoxy resins and are considered hazardous environmental contaminants. A vast array of sensors and biosensors have been developed for the sensitive screening of BPs based on carbon nanomaterials (carbon nanotubes, fullerenes, graphene and graphene oxide), quantum dots, metal and metal oxide nanocomposites, polymer nanocomposites, metal organic frameworks, ionic liquids and molecularly imprinted polymers. This review is devoted mainly to a variety of sensitive, selective and reliable sensing and biosensing methods for the detection of BPs using electrochemistry, fluorescence, colorimetry, surface plasmon resonance, luminescence, ELISAs, circular dichroism, resonance Rayleigh scattering and adsorption techniques in plastic products, food samples, food packaging, industrial wastes, pharmaceutical products, human body fluids and many other matrices. It summarizes the advances in sensing and biosensing methods for the detection of BPs since 2010. Furthermore, the article discusses challenges and future perspectives in the development of novel sensing methods for the detection of BP analogs.
Collapse
|
45
|
Qi S, Zhao B, Zhou B, Jiang X. An electrochemical immunosensor based on pristine graphene for rapid determination of ractopamine. Chem Phys Lett 2017. [DOI: 10.1016/j.cplett.2017.07.055] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
46
|
Freestanding and flexible graphene papers as bioelectrochemical cathode for selective and efficient CO 2 conversion. Sci Rep 2017; 7:9107. [PMID: 28831188 PMCID: PMC5567247 DOI: 10.1038/s41598-017-09841-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Accepted: 07/31/2017] [Indexed: 12/19/2022] Open
Abstract
During microbial electrosynthesis (MES) driven CO2 reduction, cathode plays a vital role by donating electrons to microbe. Here, we exploited the advantage of reduced graphene oxide (RGO) paper as novel cathode material to enhance electron transfer between the cathode and microbe, which in turn facilitated CO2 reduction. The acetate production rate of Sporomusa ovata-driven MES reactors was 168.5 ± 22.4 mmol m−2 d−1 with RGO paper cathodes poised at −690 mV versus standard hydrogen electrode. This rate was approximately 8 fold faster than for carbon paper electrodes of the same dimension. The current density with RGO paper cathodes of 2580 ± 540 mA m−2 was increased 7 fold compared to carbon paper cathodes. This also corresponded to a better cathodic current response on their cyclic voltammetric curves. The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.3% with RGO paper cathodes and 83.8 ± 4.2% with carbon paper cathodes, respectively. Furthermore, more intensive cell attachment was observed on RGO paper electrodes than on carbon paper electrodes with confocal laser scanning microscopy and scanning electron microscopy. These results highlight the potential of RGO paper as a promising cathode for MES from CO2.
Collapse
|
47
|
Kusiak-Nejman E, Wanag A, Kowalczyk Ł, Kapica-Kozar J, Colbeau-Justin C, Mendez Medrano MG, Morawski AW. Graphene oxide-TiO 2 and reduced graphene oxide-TiO 2 nanocomposites: Insight in charge-carrier lifetime measurements. Catal Today 2017. [DOI: 10.1016/j.cattod.2016.11.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
48
|
Temperature and pH sensors based on graphenic materials. Biosens Bioelectron 2017; 91:870-877. [DOI: 10.1016/j.bios.2017.01.062] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 01/24/2017] [Accepted: 01/26/2017] [Indexed: 11/23/2022]
|
49
|
Datta M, Desai D, Kumar A. Gene Specific DNA Sensors for Diagnosis of Pathogenic Infections. Indian J Microbiol 2017; 57:139-147. [PMID: 28611490 DOI: 10.1007/s12088-017-0650-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Accepted: 04/13/2017] [Indexed: 11/24/2022] Open
Abstract
Gene specific DNA based sensors have potential applications for rapid and real time monitoring of hybridization signal with the target nucleic acid of pathogens. Different types of DNA based sensors and their applications have been studied for rapid and accurate detection of pathogens causing human diseases. These sensors are based on surface plasmon resonance, quantum-dots, molecular beacons, piezoelectric and electrochemical etc. Curbing epidemics at an early stage is one of the massive challenges in healthcare systems. Timely detection of the causative organism may provide a solution to restrain mortality caused by the disease. With the advent of interdisciplinary sciences, bioelectronics has emerged as an effective alternative for disease diagnostics. Gene specific DNA sensors present themselves as cost-effective, sensitive and specific platforms for detection of disease causing pathogens. The mini review explores different transducer based sensors and their potential in diagnosis of acute and chronic diseases.
Collapse
Affiliation(s)
- Manali Datta
- Amity Institute of Biotechnology, Amity University Rajasthan, Jaipur, Rajasthan 302007 India
| | - Dignya Desai
- Amity Institute of Biotechnology, Amity University Rajasthan, Jaipur, Rajasthan 302007 India
| | - Ashok Kumar
- CSIR-Institute of Genomics and Integrative Biology, Mall Road, Delhi, 110007 India
| |
Collapse
|
50
|
Bo X, Zhou M, Guo L. Electrochemical sensors and biosensors based on less aggregated graphene. Biosens Bioelectron 2017; 89:167-186. [DOI: 10.1016/j.bios.2016.05.002] [Citation(s) in RCA: 101] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Accepted: 05/02/2016] [Indexed: 11/26/2022]
|