1
|
Benedetti B, Ceccardi E, MacKeown H, Di Carro M, Magi E. Exploring the potentialities of a biodegradable polymeric film in sample preparation: An optimized "white" protocol to extract and quantify emerging contaminants in water. Anal Chim Acta 2024; 1311:342725. [PMID: 38816162 DOI: 10.1016/j.aca.2024.342725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/29/2024] [Accepted: 05/15/2024] [Indexed: 06/01/2024]
Abstract
BACKGROUND The introduction of white analytical chemistry encourages the development of methods characterized by a balance among greenness, productivity/feasibility and analytical performances. In the environmental analysis of emerging contaminants (ECs), for which high sensitivity and specificity are mandatory, the use of green and sustainable sample preparation needs to be coupled to a reliable analytical determination. Herein, an extraction method based on the use of a biodegradable polymeric film (Mater-Bi) and coupled to LC-MS/MS analysis was developed for the sensitive determination of ECs in wastewater. RESULTS The interaction among a range of ECs and the Mater-Bi film (a commercially available patented blend of polybutylene-terephthalate, starch and fatty acids) was investigated by two sequential experimental designs, to simultaneously study several factors and optimize extraction efficiency. The final method, resembling a fabric phase sorptive extraction, involved pH and ionic strength modification of the sample, 1h extraction and desorption in ethanol. Satisfactory recoveries from real wastewater were obtained for sixteen analytes (56-116 %), as well as excellent precision (inter-day relative standard deviations below 10 % for most compounds). Matrix effect was in the range 88-116 % at the lower pre-concentration factor, but also acceptable in most cases at the higher pre-concentration factor. LODs in matrix, from 0.004 to 0.159 μg L-1, were lower than or comparable to those from recent studies employing green extraction procedures. The method demonstrated its applicability to samples from wastewater treatment plants, allowing quantification of pharmaceuticals and UV filters at the μg L-1 and ng L-1 levels, respectively. SIGNIFICANCE For the first time, the synthetic biopolymer Mater-Bi, so far unexplored for the use in analytical chemistry, was exploited for a green, simple and extremely cheap extraction protocol. The optimized method is suitable for several ECs, guaranteeing very good accuracy, precision and specificity, also thanks to the LC-MS/MS analysis. The evaluation by green and white analytical chemistry metrics highlighted its superiority to conventional extraction methods.
Collapse
Affiliation(s)
- Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy.
| | - Erica Ceccardi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genova, Italy
| |
Collapse
|
2
|
Wang Y, Yang Q, Zhang H, Wang Z, Wu A, Luo Y, Zhou Q. For the occurrence of PPCPs from source to tap: A novel approach modified in terms of sample preservation and SPE cartridge to monitor PPCPs in our water supply. Anal Chim Acta 2024; 1308:342662. [PMID: 38740449 DOI: 10.1016/j.aca.2024.342662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 03/19/2024] [Accepted: 04/27/2024] [Indexed: 05/16/2024]
Abstract
BACKGROUND The ongoing infusion of pharmaceutical and personal care products (PPCPs) into ecosystems sustains a perpetual life cycle and leads to multi-generational exposures. Limited understanding of their environmental impact and their intrinsic ability to induce physiological effect in humans, even at low doses, pose great risks to human health. Few scholarly works have conducted systematic research into the occurrence of PPCPs within potable water systems. Concurrently, the associated monitoring techniques have not been comprehensively examined with regards to the specific nature of drinking water, namely whether the significant presence of disinfectants may influence the detection of PPCPs. RESULTS A modified approach in terms of detailed investigation of sample preservation and optimization of an in-lab fabricated solid phase extraction (SPE) cartridge filled with DVB-VP and PS-DVB sorbent was proposed. Favorable methodological parameters were achieved, with correlation coefficients spanning from 0.9866 to 0.9998. The LODs of the PPCPs fluctuated from 0.001 to 2 μg L-1, while the LOQs varied from 0.002 to 5 μg L-1. The analysis of spiked samples disclosed a methodological precision of 2.31-9.86 % and a recovery of 52.4-119 %. We utilized the established method for analyzing 14 water samples of three categories (source water, finished water and tap water) from five centralized water supply plants. A total of 24 categories encompassing 72 PPCPs were detected, with the concentrations of PPCPs manifested a marked decrease from source water to finished water and finally to tap water. SIGNIFICANCE Our research meticulously examined the enhancement and purification effects of widely used commercial SPE cartridges and suggested the use of in-lab fabricated SPE cartridges packed with DVB-VP and PS-DVB adsorbents. We also conducted a systematic evaluation of the need to incorporate ascorbic acid and sodium thiosulfate as preservatives for PPCP measurement, in consideration of the unique characteristics of drinking water matrices, specifically, the significant concentration levels of disinfectants. Furthermore, the proposed method was effectively employed to study the presence of PPCPs in source water, finished water, and tap water collected from centralized water supply plants.
Collapse
Affiliation(s)
- Yu Wang
- Chongqing Center for Disease Control and Prevention, Chongqing, China.
| | - Qianzhan Yang
- Shimadzu (China) Corporation, Chongqing Branch, China
| | - Huadong Zhang
- Chongqing Center for Disease Control and Prevention, Chongqing, China
| | - Zhenghong Wang
- Chongqing Center for Disease Control and Prevention, Chongqing, China
| | - Ailin Wu
- Chongqing Center for Disease Control and Prevention, Chongqing, China
| | - Yun Luo
- Raykol Group Corp. Ltd., Xiamen, Fujian, China
| | - Qianru Zhou
- Chongqing Center for Disease Control and Prevention, Chongqing, China; College of Public Health, Chongqing Medical University, Chongqing, China.
| |
Collapse
|
3
|
Huang G, Su M, Liu Y, Zhang W, Yang J, Xu Z, Li S. Comparative Study of Hyper-crosslinked Polymer-Solid Phase Microextraction and Stir Bar Fabric Phase Sorptive Extraction for Simultaneous Determination of Fluoroquinolones in Water. Chromatographia 2022. [DOI: 10.1007/s10337-022-04165-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
4
|
Liu Z, Li W, Zhu X, Hua R, Wu X, Xue J. Combination of polyurethane and polymethyl methacrylate thin films as a microextraction sorbent for rapid adsorption and sensitive determination of neonicotinoid insecticides in fruit juice and tea by ultra high performance liquid chromatography with tandem mass spectrometry. J Chromatogr A 2021; 1659:462646. [PMID: 34735961 DOI: 10.1016/j.chroma.2021.462646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/16/2021] [Accepted: 10/18/2021] [Indexed: 11/16/2022]
Abstract
An economical and effective thin film microextraction (TFME) for simultaneous analysis of ten neonicotinoid insecticides and metabolites in fruit juice and tea, was developed based on the combination of polyurethane (PU) and polymethyl methacrylate (PMMA) films as the sorbent followed by ultra high performance liquid chromatography with tandem mass spectrometry. The PU/PMMA composite was evidenced to possess rapid adsorption and strong accumulation towards neonicotinoids compared with the films used alone. A series of parameters were optimized, and the agitation mode, film size, ionic strength, desorption solvent and sample pH were found to dominate the microextraction process rather than the extraction temperature, agitation time and sample volume. The thin films are cost effective and efficient for single use analysis, but still can be reused at least 8 times with no significant loss in performance. The ten neonicotinoids were measured with good recoveries (81.1-107.9%), high enrichment factors (up to 135), low limits of detection (0.001-0.1 µg L-1), and wide linearity range (1-500 µg L-1, r2>0.9981) in fruit juice (apple, lemon, and pomegranate) and tea (green tea and black tea) samples. The proposed method was successfully applied to commercial fruit and tea drinks, and no samples were tested positive on target neonicotinoids. The PU/PMMA based TFME has shown great potential as an alternative to exhaustive extraction techniques for routine screening of trace neonicotinoids in fruit juice and tea by simplifying the analytical procedure, shortening the operation time, and lowering the material expense.
Collapse
Affiliation(s)
- Zikun Liu
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China
| | - Wenhui Li
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China
| | - Xianbin Zhu
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China
| | - Rimao Hua
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China
| | - Xiangwei Wu
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China
| | - Jiaying Xue
- College of Resources and Environment, Anhui Agricultural University, Key Laboratory of Agri-food Safety of Anhui Province, Hefei 230036, P. R. China.
| |
Collapse
|
5
|
An Improved Stir Fabric-Phase Sorptive Extraction Combined with Ultra-High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis for the Determination of 48 Pesticide Residues in Vegetable Samples. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-021-02183-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Meng Y, Liu W, Liu X, Zhang J, Peng M, Zhang T. A review on analytical methods for pharmaceutical and personal care products and their transformation products. J Environ Sci (China) 2021; 101:260-281. [PMID: 33334521 DOI: 10.1016/j.jes.2020.08.025] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 08/11/2020] [Accepted: 08/21/2020] [Indexed: 05/18/2023]
Abstract
Pharmaceutical and personal care products (PPCPs) and corresponding transformation products have caused widespread concern due to their persistent emissions and potential toxicity. They have wide octanol-water partition coefficients (Kow) and different ionization constants (pKa) resulting in a poor analysis accuracy and efficiency. A suitable analytical method is the first prerequisite for further research on their environmental behavior to prioritize the substances. This study reviewed a full-scale analytical protocol for environmental samples in the recent ten years: from sampling to instrumental methods. Passive sampling techniques were compared and recommended for long-term continuous and scientific observation. A quick and effective sample extraction and clean-up method are highly required. Chromatographic methods coupled to mass spectrometry for determining PPCPs with a wide range of logKow (-7.53 to 10.80) were summed up. High-resolution mass spectrometry was confirmed to be a promising strategy for screening unknown transformation products, which would provide a nanogram level of detection limits and more accurate mass resolution. Screening strategies and mass change principles were summarized in detail. The recovery rate was important in multiple contaminants analysis identification and factors affecting the recovery rate of PPCPs were also discussed in this review, including sample matrix, target compounds characteristics, extraction method and solid-phase adsorbent. This review provides useful information for the selection of appropriate analytical methods and future development directions.
Collapse
Affiliation(s)
- Yuan Meng
- Department of Environmental Science and Engineering, Beijing Environmental Pollution Control and Resource Engineering Research Center, Beijing University of Chemical Technology, Beijing 100029, China
| | - Weiyi Liu
- Department of Environmental Science and Engineering, Beijing Environmental Pollution Control and Resource Engineering Research Center, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xiaohui Liu
- National Engineering Laboratory for Lake Pollution Control and Ecological Restoration, State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Jinlan Zhang
- Department of Environmental Science and Engineering, Beijing Environmental Pollution Control and Resource Engineering Research Center, Beijing University of Chemical Technology, Beijing 100029, China
| | - Meng Peng
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Tingting Zhang
- Department of Environmental Science and Engineering, Beijing Environmental Pollution Control and Resource Engineering Research Center, Beijing University of Chemical Technology, Beijing 100029, China.
| |
Collapse
|
7
|
Montesdeoca-Esponda S, Torres-Padrón ME, Sosa-Ferrera Z, Santana-Rodríguez JJ. Fate and distribution of benzotriazole UV filters and stabilizers in environmental compartments from Gran Canaria Island (Spain): A comparison study. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 756:144086. [PMID: 33280864 DOI: 10.1016/j.scitotenv.2020.144086] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 10/23/2020] [Accepted: 11/20/2020] [Indexed: 05/25/2023]
Abstract
Tourism is an economic sector of great importance worldwide. In coastal areas, this activity is associated with the use of personal care products, such as ultraviolet (UV) filters and stabilizers. Therefore, assessing their presence and the exposure of living organisms to the impact of this kind of pollutant in such areas could be especially important. The Canary Islands (Spain) are considered an outermost region, and their main economic activity is based on tourism, both national and international. Thus, this area could be remarkably vulnerable to this kind of pollution, and its characterization could be useful to infer conclusions for other similar regions. With this aim, the occurrence of organic UV filters and stabilizers in different environmental matrices in Gran Canaria Island is presented in this work. Six benzotriazole compounds, UV-P, UV-326, UV-327, UV-328, UV-329 and UV-360, were found in wastewater, seawater, sludge, sediment, seaweed and fish samples. The numerous studies devoted to establishing the distribution of these target compounds in many different matrices on a touristic and particularly overcrowded island such as Gran Canaria can be used to understand the pollution situation in similar locations. The works in which determination procedures using different extraction techniques were optimized and validated for the analysis of liquid and solid samples are summarized. They are critically discussed regarding their characteristics and analytical parameters. This research is of interest to environmental managers specializing in the conservation of coastal areas where tourism is an important industry since the active components of UV filters and stabilizers can bioaccumulate and biomagnify in the trophic chain.
Collapse
Affiliation(s)
- Sarah Montesdeoca-Esponda
- Instituto Universitario de Estudios Ambientales y Recursos Naturales (i-UNAT), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - María Esther Torres-Padrón
- Instituto Universitario de Estudios Ambientales y Recursos Naturales (i-UNAT), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain.
| | - Zoraida Sosa-Ferrera
- Instituto Universitario de Estudios Ambientales y Recursos Naturales (i-UNAT), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - José Juan Santana-Rodríguez
- Instituto Universitario de Estudios Ambientales y Recursos Naturales (i-UNAT), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| |
Collapse
|
8
|
Kabir A, Samanidou V. Fabric Phase Sorptive Extraction: A Paradigm Shift Approach in Analytical and Bioanalytical Sample Preparation. Molecules 2021; 26:865. [PMID: 33562079 PMCID: PMC7915638 DOI: 10.3390/molecules26040865] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/01/2021] [Accepted: 02/04/2021] [Indexed: 12/18/2022] Open
Abstract
Fabric phase sorptive extraction (FPSE) is an evolutionary sample preparation approach which was introduced in 2014, meeting all green analytical chemistry (GAC) requirements by implementing a natural or synthetic permeable and flexible fabric substrate to host a chemically coated sol-gel organic-inorganic hybrid sorbent in the form of an ultra-thin coating. This construction results in a versatile, fast, and sensitive micro-extraction device. The user-friendly FPSE membrane allows direct extraction of analytes with no sample modification, thus eliminating/minimizing the sample pre-treatment steps, which are not only time consuming, but are also considered the primary source of major analyte loss. Sol-gel sorbent-coated FPSE membranes possess high chemical, solvent, and thermal stability due to the strong covalent bonding between the fabric substrate and the sol-gel sorbent coating. Subsequent to the extraction on FPSE membrane, a wide range of organic solvents can be used in a small volume to exhaustively back-extract the analytes after FPSE process, leading to a high preconcentration factor. In most cases, no solvent evaporation and sample reconstitution are necessary. In addition to the extensive simplification of the sample preparation workflow, FPSE has also innovatively combined the extraction principle of two major, yet competing sample preparation techniques: solid phase extraction (SPE) with its characteristic exhaustive extraction, and solid phase microextraction (SPME) with its characteristic equilibrium driven extraction mechanism. Furthermore, FPSE has offered the most comprehensive cache of sorbent chemistry by successfully combining almost all of the sorbents traditionally used exclusively in either SPE or in SPME. FPSE is the first sample preparation technique to exploit the substrate surface chemistry that complements the overall selectivity and the extraction efficiency of the device. As such, FPSE indeed represents a paradigm shift approach in analytical/bioanalytical sample preparation. Furthermore, an FPSE membrane can be used as an SPME fiber or as an SPE disk for sample preparation, owing to its special geometric advantage. So far, FPSE has overwhelmingly attracted the interest of the separation scientist community, and many analytical scientists have been developing new methodologies by implementing this cutting-edge technique for the extraction and determination of many analytes at their trace and ultra-trace level concentrations in environmental samples as well as in food, pharmaceutical, and biological samples. FPSE offers a total sample preparation solution by providing neutral, cation exchanger, anion exchanger, mixed mode cation exchanger, mixed mode anion exchanger, zwitterionic, and mixed mode zwitterionic sorbents to deal with any analyte regardless of its polarity, ionic state, or the sample matrix where it resides. Herein we present the theoretical background, synthesis, mechanisms of extraction and desorption, the types of sorbents, and the main applications of FPSE so far according to different sample categories, and to briefly show the progress, advantages, and the main principles of the proposed technique.
Collapse
Affiliation(s)
- Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, 11200 SW 8th St, Miami, FL 33199, USA;
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
9
|
Exploring the Efficiency of UHPLC-Orbitrap MS for the Determination of 20 Pharmaceuticals and Acesulfame K in Hospital and Urban Wastewaters with the Aid of FPSE. SEPARATIONS 2020. [DOI: 10.3390/separations7030046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Aside from the classical residues of persistent organic pollutants (POPs), the occurrence of emerging contaminants (ECs) in the environment has become a subject of increasing concern due to their harmful impact on the aquatic environment. Wastewater treatment plant (WWTP) effluents are major sources of environmental pollution. Therefore, data concerning their existence is required. In this study, twenty compounds representative of different drug groups considered ECs and belonging to antibiotics, antipsychotics, anti-inflammatory drugs plus acesulfame K were selected to be accurately detected and quantified with UHPLC–LTQ-Orbitrap MS in hospital and urban WWTP effluents. Chromatographic parameters (column efficiency, mobile phase, etc.), as well as mass spectrometry conditions concerning ionization mode and Orbitrap analysis (ESI options, mass resolving power, AGC target, tube lens, injection time), were evaluated. Moreover, a novel fabric phase sorptive extraction (FPSE) method based on fiber glass coated with PEG300 was employed as sample preparation process. Experimental parameters affecting extraction and desorption steps such as sample pH, extraction time, ionic strength, elution time and solvent have been optimized. The optimized methodology was validated providing excellent linearity (R2 > 0.99), and low detection and quantification limits up to 3.1 and 9.3 ng/L, for carbamazepine, respectively. Relative recoveries ranged from 81.1% to 114.0%, while a medium matrix effect for most of the target compounds occurred. Applying the above analytical method in effluents of WWTPs from NW Greece, nine compounds were quantified with concentrations that varied from 55.4 to 728.4 ng/L.
Collapse
|
10
|
Investigating the Utility of Fabric Phase Sorptive Extraction and HPLC-UV-Vis/DAD to Determine Antidepressant Drugs in Environmental Aqueous Samples. SEPARATIONS 2020. [DOI: 10.3390/separations7030039] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Depression is considered to be one of the most prevalent mental disorders in humans. Antidepressant drugs are released in large concentrations and cause adverse effects on the environment and/or human health. Fabric Phase Sorptive Extraction (FPSE), a contemporary solid sorbent-handling technique, is a quick, sensitive, and simple analytical process. This paper describes a micro-extraction FPSE procedure coupled with High-Performance Liquid-Chromatography–Photodiode Array Detection (FPSE-HPLC–DAD) for the simultaneous extraction and analysis of five antidepressants, namely citalopram, clozapine, mirtazapine, bupropion and sertraline. Three fabric media (Whatman Cellulose filter, Whatman Microfiber Glass filter and Polylactic acid disks) and two different sol–gel sorbents (polyethylene glycol (PEG 300), alongside poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG 5.800)) were tested. The best FPSE device was observed to be the microfiber glass filter coated with PEG 300 sol–gel sorbent. In addition, the parameters that affect the efficiency of the process (FPSE media and sorbents, sample pH, extraction time, elution time, etc.) were optimized. The proposed methodology displays a linear range with absolute recovery values higher than 60%, RSD% of less than 13% and LOQs in the range between 1.9–10.7 μg·L−1. Finally, the method was applied in hospital and urban effluents and lake water samples, but none of the analytes were detected.
Collapse
|
11
|
Fabric phase sorptive extraction followed by HPLC-PDA detection for the monitoring of pirimicarb and fenitrothion pesticide residues. Mikrochim Acta 2020; 187:337. [DOI: 10.1007/s00604-020-04306-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Accepted: 04/29/2020] [Indexed: 12/13/2022]
|
12
|
Kaur R, Heena, Kaur R, Grover A, Rani S, Malik AK, Kabir A, Furton KG. Trace determination of parabens in cosmetics and personal care products using fabric‐phase sorptive extraction and high‐performance liquid chromatography with UV detection. J Sep Sci 2020; 43:2626-2635. [DOI: 10.1002/jssc.201900978] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2019] [Revised: 03/29/2020] [Accepted: 03/30/2020] [Indexed: 01/09/2023]
Affiliation(s)
- Ramandeep Kaur
- Department of ChemistryPunjabi University Patiala Punjab India
| | - Heena
- Department of ChemistryPunjabi University Patiala Punjab India
- Department of ChemistryGSSDGS Khalsa College Patiala Punjab India
| | - Ripneel Kaur
- Department of ChemistryPunjabi University Patiala Punjab India
| | - Aman Grover
- Department of ChemistryPunjabi University Patiala Punjab India
| | - Susheela Rani
- Department of ChemistryPunjabi University Patiala Punjab India
| | | | - Abuzar Kabir
- Department of Chemistry and BiochemistryInternational Forensic Research InstituteFlorida International University Miami FL
| | - Kenneth G. Furton
- Department of Chemistry and BiochemistryInternational Forensic Research InstituteFlorida International University Miami FL
| |
Collapse
|
13
|
Tartaglia A, Kabir A, D'Ambrosio F, Ramundo P, Ulusoy S, Ulusoy H, Merone G, Savini F, D'Ovidio C, Grazia UD, Furton K, Locatelli M. Fast off-line FPSE-HPLC-PDA determination of six NSAIDs in saliva samples. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1144:122082. [DOI: 10.1016/j.jchromb.2020.122082] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/20/2020] [Accepted: 03/24/2020] [Indexed: 01/08/2023]
|
14
|
Ruan X, Xing L, Peng J, Li S, Song Y, Sun Q. A simplified fabric phase sorptive extraction method for the determination of amphetamine drugs in water samples using liquid chromatography-mass spectrometry. RSC Adv 2020; 10:10854-10866. [PMID: 35492944 PMCID: PMC9050397 DOI: 10.1039/c9ra10138a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 02/03/2020] [Indexed: 12/04/2022] Open
Abstract
Fabric phase sorptive extraction (FPSE) can directly extract the target analytes and simultaneously determine many similar substances from complicated sample matrices. Also, it has very high chemical stability. Therefore, we used fabric phase sorptive extraction to analyze three amphetamine drugs (amphetamine (AM), methamphetamine (MAM), and 3,4-methylenedioxymethamphetamine (MDMA)) in water. This was coupled with ultrahigh-performance liquid chromatography and tandem mass spectrometry. The effects of different sorbent chemistries such as sorption time, ratios of back-extraction solvents, back-extraction time, and the salt effect on the extraction efficiency were studied; the optimum operation conditions were determined. Medium polarity polar polymer-coated FPSE media were created using short-chain poly (tetrahydrofuran) (PTHF). This is the most efficient extraction media for the analytes of interest. Under the optimized conditions, the linear range of the three amphetamine drugs were 0.1–150.0 (AM, MAM) and 0.5–200 ng mL−1 (MDMA). The correlation coefficients (γ) were 0.9947 (AM), 0.9925 (MAM), and 0.9918 (MDMA). The detection limits (LOD) were 0.025 ng mL−1 for AM, 0.029 ng mL−1 for MAM, and 0.01 ng mL−1 for MDMA. The corresponding limit of quantification values (LOQ) were 0.083 ng mL−1, 0.097 ng mL−1, and 0.031 ng mL−1, respectively. The recoveries were 73.4–91.6%, 82.6–95.4%, and 92.7–95.3%, respectively, and the relative standard deviations (RSD) were 1.65–6.88%, 1.38–6.11%, and 1.58–7.34%, respectively. Moreover, our method can be successfully applied for the analysis of amphetamines in wastewater samples, and at the same time, lays the foundation for the future detection of such substances. Fabric phase sorptive extraction (FPSE) can directly extract the target analytes and simultaneously determine many similar substances from complicated sample matrices.![]()
Collapse
Affiliation(s)
- Xiaomeng Ruan
- Criminal Investigation Police University of China
- China
| | - Limei Xing
- Criminal Investigation Police University of China
- China
| | - Ju Peng
- Criminal Investigation Police University of China
- China
| | - Shiying Li
- Criminal Investigation Police University of China
- China
| | - Yiqun Song
- Criminal Investigation Police University of China
- China
| | - Qianqian Sun
- Criminal Investigation Police University of China
- China
| |
Collapse
|
15
|
Celeiro M, Acerbi R, Kabir A, Furton KG, Llompart M. Development of an analytical methodology based on fabric phase sorptive extraction followed by gas chromatography-tandem mass spectrometry to determine UV filters in environmental and recreational waters. Anal Chim Acta X 2019; 4:100038. [PMID: 33117984 PMCID: PMC7587048 DOI: 10.1016/j.acax.2019.100038] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 12/11/2019] [Accepted: 12/15/2019] [Indexed: 10/31/2022] Open
Abstract
A novel method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been validated for the simultaneous determination of 11 UV filters (ethylhexyl salicylate, benzyl salicylate, homosalate, benzophenone-3, isoamylmethoxycinnamate, 4-methylbenzylidenecamphor, methyl anthranilate, etocrylene, 2-ethylhexylmethoxycinnamate, 2-ethylhexyl p-dimethylaminobenzoate, and octocrylene), in natural and recreational waters. Major experimental parameters affecting FPSE procedure have been optimized to obtain the highest extraction efficiency. Different types and sizes of sol-gel coated FPSE media, sample volume, extraction time, and type and volume of desorption solvent were evaluated. The optimal conditions involved the use of a (2.0 × 2.5) cm2 FPSE device with PDMS based coating for the extraction of 20 mL of water for 20 min. The quantitative desorption of the target compounds was performed with 0.5-1 mL of ethyl acetate. The method was satisfactorily validated in terms of linearity, precision, repeatability and reproducibility. Recovery studies were performed at different concentration levels in real water matrices to show its suitability, obtaining mean values about 90% and satisfactory precision. LODs were at the low ng L-1 in all cases. Finally, the validated FPSE-GC-MS/MS method was applied to different real samples, including environmental water (lake, river, seawater) and recreational water (swimming-pool), where 8 out of the 11 studied compounds were detected at concentrations between 0.12-123 μg L-1. FPSE is proposed as an efficient and simple alternative to other extraction and microextraction techniques for the analysis of UV filters in waters. Since no matrix effects were observed, quantification could be carried out by conventional calibration with standard solutions, without the need to perform the complete FPSE procedure, thus allowing a higher throughput in comparison with other microextraction techniques.
Collapse
Affiliation(s)
- Maria Celeiro
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| | - Ruben Acerbi
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL-33199, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL-33199, USA
| | - Maria Llompart
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| |
Collapse
|
16
|
Tartaglia A, Kabir A, Ulusoy S, Sperandio E, Piccolantonio S, Ulusoy HI, Furton KG, Locatelli M. FPSE-HPLC-PDA analysis of seven paraben residues in human whole blood, plasma, and urine. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1125:121707. [DOI: 10.1016/j.jchromb.2019.06.034] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/21/2019] [Accepted: 06/27/2019] [Indexed: 12/16/2022]
|
17
|
Taraboletti A, Goudarzi M, Kabir A, Moon BH, Laiakis EC, Lacombe J, Ake P, Shoishiro S, Brenner D, Fornace AJ, Zenhausern F. Fabric Phase Sorptive Extraction-A Metabolomic Preprocessing Approach for Ionizing Radiation Exposure Assessment. J Proteome Res 2019; 18:3020-3031. [PMID: 31090424 PMCID: PMC7437658 DOI: 10.1021/acs.jproteome.9b00142] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The modern application of mass spectrometry-based metabolomics to the field of radiation assessment and biodosimetry has allowed for the development of prompt biomarker screenings for radiation exposure. Our previous work on radiation assessment, in easily accessible biofluids (such as urine, blood, saliva), has revealed unique metabolic perturbations in response to radiation quality, dose, and dose rate. Nevertheless, the employment of swift injury assessment in the case of a radiological disaster still remains a challenge as current sample processing can be time consuming and cause sample degradation. To address these concerns, we report a metabolomics workflow using a mass spectrometry-compatible fabric phase sorptive extraction (FPSE) technique. FPSE employs a matrix coated with sol-gel poly(caprolactone-b-dimethylsiloxane-b-caprolactone) that binds both polar and nonpolar metabolites in whole blood, eliminating serum processing steps. We confirm that the FPSE preparation technique combined with liquid chromatography-mass spectrometry can distinguish radiation exposure markers such as taurine, carnitine, arachidonic acid, α-linolenic acid, and oleic acid found 24 h after 8 Gy irradiation. We also note the effect of different membrane fibers on both metabolite extraction efficiency and the temporal stabilization of metabolites in whole blood at room temperature. These findings suggest that the FPSE approach could work in future technology to triage irradiated individuals accurately, via biomarker screening, by providing a novel method to stabilize biofluids between collection and sample analysis.
Collapse
Affiliation(s)
- Alexandra Taraboletti
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Maryam Goudarzi
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Lerner Research Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, Ohio 44195, United States
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 Southwest Eighth Street, Miami, Florida 33199, United States
| | - Bo-Hyun Moon
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Evagelia C. Laiakis
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Jerome Lacombe
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - Pelagie Ake
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Sueoka Shoishiro
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - David Brenner
- Center for Radiological Research, Columbia University, 630 West 168th Street, New York, New York 10032, United States
| | - Albert J. Fornace
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Frederic Zenhausern
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
- Translational Genomics Research Institute, 445 North Fifth Street, Phoenix, Arizona 85004, United States
- Department of Basic Medical Sciences, College of Medicine Phoenix, 425 North Fifth Street, Phoenix, Arizona 85004, United States
| |
Collapse
|
18
|
Lioupi A, Kabir A, Furton KG, Samanidou V. Fabric phase sorptive extraction for the isolation of five common antidepressants from human urine prior to HPLC-DAD analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1118-1119:171-179. [DOI: 10.1016/j.jchromb.2019.04.045] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 04/09/2019] [Accepted: 04/22/2019] [Indexed: 10/27/2022]
|
19
|
Kaur R, Kaur R, Rani S, Malik AK, Kabir A, Furton KG. Application of fabric phase sorptive extraction with gas chromatography and mass spectrometry for the determination of organophosphorus pesticides in selected vegetable samples. J Sep Sci 2019; 42:862-870. [PMID: 30600583 DOI: 10.1002/jssc.201800854] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 11/29/2018] [Accepted: 12/03/2018] [Indexed: 12/15/2022]
Abstract
In the present work, a high-efficiency and solvent minimized microextraction technique, fabric phase sorptive extraction followed by gas chromatography and mass spectrometry analysis is proposed for the rapid determination of four organophosphorus pesticides (terbufos, malathion, chlorpyrifos, and triazofos) in vegetable samples including beans, tomato, brinjal, and cabbage. Fabric phase sorptive extraction combines the beneficial features of sol-gel derived microextraction sorbents with the rich surface chemistry of cellulose fabric substrate, which collectively form a highly efficient microextraction system. Fabric phase sorptive extraction membrane, when immersed directly into the sample matrix, may extract target analytes even when high percentage of matrix interferents are present. The technique also greatly simplifies sample preparation workflow. Most important fabric phase sorptive extraction parameters were investigated and optimized. The developed method displayed good linearity over the concentration range 0.5-500 ng/g. Under optimum experimental conditions, the limits of detection were found in the range of 0.033 to 0.136 ng/g. The relative standard deviations for the extraction of organophosphorus pesticides were < 5%. Subsequently, the new method was applied to beans, tomato, brinjal, and cabbage samples. The results from the real sample analysis indicate that the method is green, rapid, and economically feasible for the determination of organophosphorus pesticides in vegetable samples.
Collapse
Affiliation(s)
- Ramandeep Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| | - Ripneel Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| | - Susheela Rani
- Department of Chemistry, Punjabi University, Patiala, India
| | | | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| |
Collapse
|
20
|
Pérez-Mayán L, Rodríguez I, Ramil M, Kabir A, Furton KG, Cela R. Fabric phase sorptive extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry for the determination of fungicides and insecticides in wine. J Chromatogr A 2018; 1584:13-23. [PMID: 30502037 DOI: 10.1016/j.chroma.2018.11.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 11/02/2018] [Accepted: 11/15/2018] [Indexed: 12/31/2022]
Abstract
In this work, fabric phase sorptive extraction (FPSE) is investigated for the extraction and preconcentration of ultra-trace level residues of fungicides (19 compounds) and insecticides (3 species) in wine samples. Subsequently, the preconcentrated analytes are selectively determined using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Parameters affecting the efficiency and repeatability of the extraction are evaluated in depth; moreover, the proposed method is characterized in terms of linear response range, trueness, precision and limits of quantification (LOQs). The set-up of the extraction process and the type of coating were the variables exerting the most prominent effects in the repeatability and the yield of the extraction, respectively. Under optimized conditions, samples (10 mL of wine diluted with the same volume of ultrapure water) were extracted with a small amount of cellulose fabric (3 discs with 4 mm of diameter: total surface 0.38 cm2) coated with a sol-gel polyethylene glycol sorbent (sorbent amount 3.3 mg), immersed in the diluted sample, without being in direct contact with the PTFE covered magnetic stir bar. Following the overnight extraction step, analytes were quantitatively recovered using only 0.3 mL of an ACN-MeOH (80:20) mixture. Under equilibrium sampling conditions, the linear response range of the method varied from 0.2 to 200 ng mL-1, with limits of quantification (LOQs) between 0.03 and 0.3 ng mL-1. Relative recoveries ranged from 77 ± 6% to 118 ± 4%, and from 87 ± 4% to 121 ± 6% for red and white wines, respectively. Application of the optimized method to commercial wines demonstrated the existence of up to 9 out of 22 investigated compounds in the same wine sample. The compound identified at the highest concentration was iprovalicarb (IPR), with a value of 130 ± 9 ng mL-1 in a commercial white wine.
Collapse
Affiliation(s)
- L Pérez-Mayán
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| | - I Rodríguez
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| | - M Ramil
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain.
| | - A Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8thStreet, Miami, FL, 33199, USA.
| | - K G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8thStreet, Miami, FL, 33199, USA
| | - R Cela
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| |
Collapse
|
21
|
Sun T, Wang D, Tang Y, Xing X, Zhuang J, Cheng J, Du Z. Fabric-phase sorptive extraction coupled with ion mobility spectrometry for on-site rapid detection of PAHs in aquatic environment. Talanta 2018; 195:109-116. [PMID: 30625520 DOI: 10.1016/j.talanta.2018.11.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 11/01/2018] [Accepted: 11/05/2018] [Indexed: 01/03/2023]
Abstract
The contamination of water is a high risk to human health, so there is an urgent need to rapidly detect water pollution in the field. Ion mobility spectrometry (IMS) is suitable for on-site analysis with the merit of rapid analysis and compact size. In this study, we developed a new method which coupled fabric phase sorptive extraction (FPSE) with IMS for rapid detection of polycyclic aromatic hydrocarbons (PAHs) in water present in the field. Polydimethylsiloxane (PDMS) was coated on the glass fiber cloth through a sol-gel reaction. After extracting the PAHs in water, the fabric coated PDMS could be directly put into the inlet of IMS instrument for thermal desorption. The PAHs were analyzed by the IMS instrument operated in the positive ion mode with a corona discharge (CD) ionization source. The primary parameters affecting extraction efficiency such as extraction time, extraction temperature, and ionic strength were investigated and optimized by using phenanthrene (Phe), benzo[a]anthracene (BaA) and benzo[a]pyrene (BaP) as model compounds. Under the optimal conditions, the FPSE-IMS detection limits were 5 ng ml-1,8 ng ml-1 and 10 ng ml-1 respectively. Satisfactory recoveries were obtained in the range from 80.5% to 100.5% by testing the spiked real water samples and validated by the standard method(HJ487-2009). Based on the results, the method of FPSE-IMS could be feasibly applied for monitoring the water quality on-site and providing early warning in the field.
Collapse
Affiliation(s)
- Tangqiang Sun
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Di Wang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Yan Tang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Xuebin Xing
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Jingcong Zhuang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Jiaxing Cheng
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Zhenxia Du
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China.
| |
Collapse
|
22
|
Abstract
Fabric phase sorptive extraction (FPSE) is a novel and green sample preparation technique introduced in 2014. FPSE utilizes a natural or synthetic permeable and flexible fabric substrate chemically coated with a sol-gel organic-inorganic hybrid sorbent in the form of ultra-thin coating, which leads to a fast and sensitive micro-extraction device. The flexible FPSE requires no modification of samples and allows direct extraction of analytes. Sol-gel sorbent-coated FPSE media possesses high chemical, solvent, and thermal stability due to the strong covalent bonding between the substrate and the sol-gel sorbent. Therefore, any elution solvent can be used in a small volume, which achieves a high pre-concentration factor without requiring any solvent evaporation and sample reconstitution step. Taking into consideration the complexity of the samples and the need of further minimization and automation, some new, alternative modes of the FPSE have also been developed. Therefore, FPSE has attracted the interest of the scientific community that deals with sample pre-treatment and has been successfully applied for the extraction and determination of many analytes in environmental samples as well as in food and biological samples. The objective of the current review is to present and classify the applications of FPSE according to different sample categories and to briefly show the progress, advantages, and the main principles of the proposed technique.
Collapse
|
23
|
Kabir A, Furton KG, Tinari N, Grossi L, Innosa D, Macerola D, Tartaglia A, Di Donato V, D'Ovidio C, Locatelli M. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1084:53-63. [DOI: 10.1016/j.jchromb.2018.03.028] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 03/13/2018] [Accepted: 03/15/2018] [Indexed: 10/17/2022]
|
24
|
Novel capsule phase microextraction in combination with liquid chromatography-tandem mass spectrometry for determining personal care products in environmental water. Anal Bioanal Chem 2018; 410:2991-3001. [DOI: 10.1007/s00216-018-0984-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 02/12/2018] [Accepted: 02/23/2018] [Indexed: 12/27/2022]
|
25
|
Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation. SEPARATIONS 2017. [DOI: 10.3390/separations4040036] [Citation(s) in RCA: 87] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
26
|
Piri-Moghadam H, Alam MN, Pawliszyn J. Review of geometries and coating materials in solid phase microextraction: Opportunities, limitations, and future perspectives. Anal Chim Acta 2017; 984:42-65. [PMID: 28843569 DOI: 10.1016/j.aca.2017.05.035] [Citation(s) in RCA: 177] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 05/23/2017] [Accepted: 05/25/2017] [Indexed: 12/18/2022]
Abstract
The development of new support and geometries of solid phase microextraction (SPME), including metal fiber assemblies, coated-tip, and thin film microextraction (TFME) (i.e. self-supported, fabric and blade supported), as well as their effects on diffusion and extraction rate of analytes were discussed in the current review. Application of main techniques widely used for preparation of a variety of coating materials of SPME, including sol-gel technique, electrochemical and electrospinning methods as well as the available commercial coatings, were presented. Advantages and limitations of each technique from several aspects, such as range of application, biocompatibility, availability in different geometrical configurations, method of preparation, incorporation of various materials to tune the coating properties, and thermal and physical stability, were also investigated. Future perspectives of each technique to improve the efficiency and stability of the coatings were also summarized. Some interesting materials including ionic liquids (ILs), metal organic frameworks (MOFs) and particle loaded coatings were briefly presented.
Collapse
Affiliation(s)
- Hamed Piri-Moghadam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Md Nazmul Alam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
27
|
Abstract
The theory and working principle of fabric phase sorptive extraction (FPSE) is presented. FPSE innovatively integrates the benefits of sol–gel coating technology and the rich surface chemistry of cellulose/polyester/fiberglass fabrics, resulting in a microextraction device with very high sorbent loading in the form of an ultra-thin coating. This porous sorbent coating and the permeable substrate synergistically facilitate fast extraction equilibrium. The flexibility of the FPSE device allows its direct insertion into original, unmodified samples of different origin. Strong chemical bonding between the sol–gel sorbent and the fabric substrate permits the exposure of FPSE devices to any organic solvent for analyte back-extraction/elution. As a representative sorbent, sol–gel poly(ethylene glycol) coating was generated on cellulose substrates. Five (cm2) segments of these coated fabrics were used as the FPSE devices for sample preparation using direct immersion mode. An important class of environmental pollutants—substituted phenols—was used as model compounds to evaluate the extraction performance of FPSE. The high primary contact surface area (PCSA) of the FPSE device and porous structure of the sol–gel coatings resulted in very high sample capacities and incredible extraction sensitivities in a relatively short period of time. Different extraction parameters were evaluated and optimized. The new extraction devices demonstrated part per trillion level detection limits for substitute phenols, a wide range of detection linearity, and good performance reproducibility.
Collapse
|
28
|
Abstract
Since the introduction in 2014 of fabric phase sorptive extraction (FPSE) as a sample preparation technique, it has attracted the attention of many scientists working in the field of separation science. This novel sorbent extraction technique has successfully utilized the benefits of sol–gel derived hybrid sorbents and a plethora of fabric substrates, resulting in a highly efficient, sensitive and green sample pretreatment methodology. The proposed procedure is an easy and efficient pathway to extract target analytes from different matrices providing inherent advantages such as high sample loading capacity and short pretreatment time. The present review mainly focuses on the background and sol–gel chemistry for the preparation of new fabric sorbents as well as on the applications of FPSE for extracting target analytes, from the time that it was first introduced. New modes of FPSE including stir FPSE, stir-bar FPSE, dynamic FPSE, and automated on-line FPSE are also highlighted and commented upon in detail. FPSE has been effectively applied for the determination of various organic and inorganic analytes in different types of environmental and biological samples in high throughput analytical, environmental, and toxicological laboratories.
Collapse
|
29
|
Aznar M, Úbeda S, Nerin C, Kabir A, Furton KG. Fabric phase sorptive extraction as a reliable tool for rapid screening and detection of freshness markers in oranges. J Chromatogr A 2017; 1500:32-42. [PMID: 28433435 DOI: 10.1016/j.chroma.2017.04.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 04/04/2017] [Accepted: 04/06/2017] [Indexed: 01/03/2023]
Abstract
A simple, fast and sensitive analyte extraction method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QTOF-MS) analysis was developed for the analysis of 12 volatile compounds that represent most of the principal chemical families possessing different polarities and volatilities. Five FPSE media coated with different sol-gel sorbent chemistries having different polarities and selectivities were studied: long chain poly(dimethylsiloxane) (PDMS), short chain poly(tetrahydrofuran) (PTHF), Carbowax 20M (CW20M), short chain poly(dimethyl siloxane) (SC PDMS) and polyethylene glycol-polypropylene glycol-polyethylene glycol triblock copolymer (PEG-PPG-PEG). CW20M coated FPSE media was found to be the most efficient extraction media for the analytes of interest in the intended study. The developed methodology was applied to the analysis of orange juice obtained from fresh oranges and oranges after storing at 5°C for two months in order to identify the best chemical markers, both volatiles and non-volatiles, attributed to the freshness of orange. For this purpose, aliquots of the same juice extracts were analysed by GC-MS as well as by UPLC-QTOF-MS. Monoterpenes and terpenoids, such as terpinene, citronellal or estragole were among the volatile compounds that endured the biggest decrease after the extended storage period. Three non-volatile compounds including one amide (subaphyllin) and two flavanoids (tangeretin and nobiletin) also showed a clear decrease in signal intensity (>70%) after orange stored for two months.
Collapse
Affiliation(s)
- M Aznar
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain
| | - S Úbeda
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain
| | - C Nerin
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain.
| | - A Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA.
| | - K G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA
| |
Collapse
|
30
|
Inter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples. Anal Chim Acta 2017; 964:74-84. [DOI: 10.1016/j.aca.2017.02.014] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Revised: 01/30/2017] [Accepted: 02/01/2017] [Indexed: 12/22/2022]
|
31
|
Alcudia-León M, Lucena R, Cárdenas S, Valcárcel M, Kabir A, Furton KG. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography–mass spectrometry. J Chromatogr A 2017; 1488:17-25. [DOI: 10.1016/j.chroma.2017.01.077] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 01/12/2017] [Accepted: 01/27/2017] [Indexed: 11/25/2022]
|
32
|
Locatelli M, Kabir A, Innosa D, Lopatriello T, Furton KG. A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1040:192-198. [DOI: 10.1016/j.jchromb.2016.10.045] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Revised: 10/07/2016] [Accepted: 10/26/2016] [Indexed: 01/17/2023]
|
33
|
Fiscal-Ladino JA, Obando-Ceballos M, Rosero-Moreano M, Montaño DF, Cardona W, Giraldo LF, Richter P. Ionic liquids intercalated in montmorillonite as the sorptive phase for the extraction of low-polarity organic compounds from water by rotating-disk sorptive extraction. Anal Chim Acta 2016; 953:23-31. [PMID: 28010739 DOI: 10.1016/j.aca.2016.11.067] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 10/26/2016] [Accepted: 11/24/2016] [Indexed: 01/09/2023]
Abstract
Montmorillonite (MMT) clays were modified by the intercalation into their galleries of ionic liquids (IL) based on imidazolium quaternary ammonium salts. This new eco-materials exhibited good features for use as a sorptive phase in the extraction of low-polarity analytes from aqueous samples. Spectroscopic analyses of the modified clays were conducted and revealed an increase in the basal spacing and a shifting of the reflection plane towards lower values as a consequence of the effective intercalation of organic cations into the MMT structure. The novel sorbent developed herein was assayed as the sorptive phase in rotating-disk sorptive extraction (RDSE), using polychlorinated biphenyls (PCBs), representative of low-polarity pollutants, as model analytes. The final determination was made by gas chromatography with electron capture detection. Among the synthetized sorptive phases, the selected system for analytical purposes consisted of MMT modified with the 1-hexadecyl-3-methylimidazolium bromide (HDMIM-Br) IL. Satisfactory analytical features were achieved using a sample volume of 5 mL: the relative recoveries from a wastewater sample were higher than 80%, the detection limits were between 3 ng L-1 and 43 ng L-1, the precision (within-run precision) expressed as the relative standard deviation ranged from 2% to 24%, and the enrichment factors ranged between 18 and 28. Using RDSE, the extraction efficiency achieved for the selected MMT-HDMIM-Br phase was compared with other commercial solid phases/supports, such as polypropylene, polypropylene with 1-octanol (as a supported liquid membrane), octadecyl (C18) and octyl (C8), and showed the highest response for all the studied analytes. Under the optimized extraction conditions, this new device was applied in the analysis of the influent of a wastewater treatment plant in Santiago (Chile), demonstrating its applicability through the good recoveries and precision achieved with real samples.
Collapse
Affiliation(s)
- Jhon A Fiscal-Ladino
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Mónica Obando-Ceballos
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Milton Rosero-Moreano
- Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No. 26-10, Manizales, Colombia
| | - Diego F Montaño
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Wilson Cardona
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Luis F Giraldo
- Química de Plantas Colombianas, Instituto de Química, Escuela de Ciencias Exactas y Naturales, Universidad de Antioquia, Calle 70 No. 52-21, A.A, 1226, Medellín, Colombia
| | - Pablo Richter
- Departamento de Química Inorgánica y Analítica, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile, Casilla 233, Santiago, Chile.
| |
Collapse
|
34
|
Piri-Moghadam H, Ahmadi F, Pawliszyn J. A critical review of solid phase microextraction for analysis of water samples. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.05.029] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
35
|
Huang G, Dong S, Zhang M, Zhang H, Huang T. Fabric phase sorptive extraction: Two practical sample pretreatment techniques for brominated flame retardants in water. WATER RESEARCH 2016; 101:547-554. [PMID: 27300591 DOI: 10.1016/j.watres.2016.06.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Revised: 05/21/2016] [Accepted: 06/03/2016] [Indexed: 06/06/2023]
Abstract
Sample pretreatment is the critical section for residue monitoring of hazardous pollutants. In this paper, using the cellulose fabric as host matrix, three extraction sorbents such as poly (tetrahydrofuran) (PTHF), poly (ethylene glycol) (PEG) and poly (dimethyldiphenylsiloxane) (PDMDPS), were prepared on the surface of the cellulose fabric. Two practical extraction techniques including stir bar fabric phase sorptive extraction (stir bar-FPSE) and magnetic stir fabric phase sorptive extraction (magnetic stir-FPSE) have been designed, which allow stirring of fabric phase sorbent during the whole extraction process. In the meantime, three brominated flame retardants (BFRs) [tetrabromobisphenol A (TBBPA), tetrabromobisphenol A bisallylether (TBBPA-BAE), tetrabromobisphenol A bis(2,3-dibromopropyl)ether (TBBPA-BDBPE)] in the water sample were selected as model analytes for the practical evaluation of the proposed two techniques using high-performance liquid chromatography (HPLC). Moreover, various experimental conditions affecting extraction process such as the type of fabric phase, extraction time, the amount of salt and elution conditions were also investigated. Due to the large sorbent loading capacity and unique stirring performance, both techniques possessed high extraction capability and fast extraction equilibrium. Under the optimized conditions, high recoveries (90-99%) and low limits of detection (LODs) (0.01-0.05 μg L(-1)) were achieved. In addition, the reproducibility was obtained by evaluating the intraday and interday precisions with relative standard deviations (RSDs) less than 5.1% and 6.8%, respectively. The results indicated that two pretreatment techniques were promising and practical for monitoring of hazardous pollutants in the water sample. Due to low solvent consumption and high repeated use performance, proposed techniques also could meet green analytical criteria.
Collapse
Affiliation(s)
- Guiqi Huang
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
| | - Sheying Dong
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China; College of Sciences, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China.
| | - Mengfei Zhang
- College of Sciences, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
| | - Haihan Zhang
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
| | - Tinglin Huang
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
| |
Collapse
|
36
|
Aznar M, Alfaro P, Nerin C, Kabir A, Furton K. Fabric phase sorptive extraction: An innovative sample preparation approach applied to the analysis of specific migration from food packaging. Anal Chim Acta 2016; 936:97-107. [DOI: 10.1016/j.aca.2016.06.049] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 06/27/2016] [Accepted: 06/29/2016] [Indexed: 01/03/2023]
|
37
|
Dimpe KM, Nomngongo PN. Current sample preparation methodologies for analysis of emerging pollutants in different environmental matrices. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.05.023] [Citation(s) in RCA: 115] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
38
|
Lakade SS, Borrull F, Furton KG, Kabir A, Marcé RM, Fontanals N. Dynamic fabric phase sorptive extraction for a group of pharmaceuticals and personal care products from environmental waters. J Chromatogr A 2016; 1456:19-26. [DOI: 10.1016/j.chroma.2016.05.097] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 05/02/2016] [Accepted: 05/27/2016] [Indexed: 12/18/2022]
|
39
|
Anthemidis A, Kazantzi V, Samanidou V, Kabir A, Furton KG. An automated flow injection system for metal determination by flame atomic absorption spectrometry involving on-line fabric disk sorptive extraction technique. Talanta 2016; 156-157:64-70. [PMID: 27260436 DOI: 10.1016/j.talanta.2016.05.012] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 04/21/2016] [Accepted: 05/02/2016] [Indexed: 10/21/2022]
Abstract
A novel flow injection-fabric disk sorptive extraction (FI-FDSE) system was developed for automated determination of trace metals. The platform was based on a minicolumn packed with sol-gel coated fabric media in the form of disks, incorporated into an on-line solid-phase extraction system, coupled with flame atomic absorption spectrometry (FAAS). This configuration provides minor backpressure, resulting in high loading flow rates and shorter analytical cycles. The potentials of this technique were demonstrated for trace lead and cadmium determination in environmental water samples. The applicability of different sol-gel coated FPSE media was investigated. The on-line formed complex of metal with ammonium pyrrolidine dithiocarbamate (APDC) was retained onto the fabric surface and methyl isobutyl ketone (MIBK) was used to elute the analytes prior to atomization. For 90s preconcentration time, enrichment factors of 140 and 38 and detection limits (3σ) of 1.8 and 0.4μgL(-1) were achieved for lead and cadmium determination, respectively, with a sampling frequency of 30h(-1). The accuracy of the proposed method was estimated by analyzing standard reference materials and spiked water samples.
Collapse
Affiliation(s)
- A Anthemidis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece.
| | - V Kazantzi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece
| | - V Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece
| | - A Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - K G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| |
Collapse
|