1
|
Das T, Das S, A BC. Fabrication of a Label-Free Immunosensor Using Surface-Engineered AuPt@GQD Core-Shell Nanocomposite for the Selective Detection of Trace Levels of Escherichia coli from Contaminated Food Samples. ACS Biomater Sci Eng 2024; 10:4018-4034. [PMID: 38816970 DOI: 10.1021/acsbiomaterials.4c00297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Fabrication of label-free immunosensors is highly necessitated due to their simplicity, cost-effectiveness, and robustness. Herein, we report the facile development of a label-free, direct, rapid, capacitive immunosensor for ultrasensitive and rapid recognition of trace levels of Escherichia coli from contaminated food samples. This was achieved using gold platinum core-shell nanoparticles loaded with graphene quantum dots (AuPt@GQDs) that were utilized as electrode modifiers. The incorporation of GQDs to the surface of AuPt core-shell nanoparticles was performed using the "greener" probe-sonication method. The electrochemical properties of AuPt@GQDs, determined using cyclic voltammetry and electrochemical impedance spectroscopy, suggested the optimized loading concentration of AuPt to be 0.05% in the core-shell nanocomposite to exhibit the highest current response. Furthermore, immobilization of anti-E. coli monoclonal antibodies (anti-E. coli mAb) onto the surface of modified electrodes was performed using amine coupling. The high specific binding of E. coli cells onto the surface of the immuno-electrode was measured as a direct function of change in transient capacitance with time that was measured at low and high frequencies. The resultant immunosensor (bovine serum albumin/anti-E. coli mAb/AuPt0.05@GQDs/FTO) demonstrated a detection range (5 to 4.5 × 103 cells/mL), with the detection limit as low as 1.5 × 102 cells/mL, and an excellent sensitivity ∼171,281.40 μF-1 mL cells-1 cm-2 without the use of any labels (R2-0.99). These findings were further verified using real sample analysis wherein the immuno-electrode demonstrated outstanding sensitivity, the highest noticed so far. More interestingly, the high resuability ∼48 weeks (RSD-5.92%) and excellent reproducibility in detection results (RSD ∼ 9.5%) testify its potential use in a clinical setting. The results reveal the usefulness of the surface-engineered AuPt@GQDs core-shell nanocomposite as an electrode modifier that can be used for the development of newer on-site monitoring devices to estimate trace levels of pathogens present as contaminants in food samples.
Collapse
Affiliation(s)
- Tushar Das
- Department of Chemistry, National Institute of Technology Patna, Bihar 800005, India
| | - Subrata Das
- Department of Chemistry, National Institute of Technology Patna, Bihar 800005, India
| | - Betty C A
- Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085, India
- Homi Bhabha National Institute, Mumbai 400085, India
| |
Collapse
|
2
|
Sun X, Song G, Hu Z, Zhang W, Luo N, Gao H. An electrochemical immunosensor based on hybrid self-assembled monolayers for rapid detection of Bombyx mori nucleopolyhedrovirus. J Invertebr Pathol 2024; 204:108080. [PMID: 38432354 DOI: 10.1016/j.jip.2024.108080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 02/26/2024] [Accepted: 02/27/2024] [Indexed: 03/05/2024]
Abstract
Bombyx mori nucleopolyhedrovirus (BmNPV) is highly contagious and poses a serious threat to sericulture production. Because there are currently no effective treatments for BmNPV, a rapid and simple detection method is urgently needed. This paper describes an electrochemical immunosensor for the detection of BmNPV. The immunosensor was fabricated by covalently immobilizing anti-BmNPV, a biorecognition element, onto the surface of the working gold electrode via 11-mercaptoundecanoic acid (MUA)/β-mercaptoethanol (ME) hybrid self-assembled monolayers. Electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) were used to characterize the electrochemical performance and morphology of the immunosensor, respectively. Under optimum conditions, the developed immunosensor exhibited a linear response to BmNPV polyhedrin in the range of 1 × 102-1 × 108 fg/mL, with a low detection limit of 14.54 fg/mL. The immunosensor also exhibited remarkable repeatability, reproducibility, specificity, accuracy, and regeneration. Normal silkworm blood was mixed with BmNPV polyhedrin and analyzed quantitatively using this sensor, and the recovery was 92.31 %-100.61 %. Additionally, the sensor was used to analyze silkworm blood samples at different time points after BmNPV infection, and an obvious antigen signal was detected at 12 h post infection. Although this result agreed with that provided by the conventional polymerase chain reaction (PCR) method, the electroanalysis method established in this study was simpler, shorter in detection period, and lower in material cost. Furthermore, this innovative electrochemical immunosensor, developed for the ultra-sensitive and rapid detection of BmNPV, can be used for the early detection of virus-infected silkworms.
Collapse
Affiliation(s)
- Xiaomei Sun
- College of Forestry, Shandong Agricultural University, Taian 271018, China
| | - Guizhen Song
- College of Forestry, Shandong Agricultural University, Taian 271018, China
| | - Zengjuan Hu
- Qingdao Agricultural Technology Extension Center, Qingdao 266100, China
| | - Wenjing Zhang
- College of Forestry, Shandong Agricultural University, Taian 271018, China
| | - Ning Luo
- College of Forestry, Shandong Agricultural University, Taian 271018, China
| | - Huiju Gao
- College of Forestry, Shandong Agricultural University, Taian 271018, China; State Forestry and Grassland Administration Key Laboratory of Silviculture in Downstream Areas of the Yellow River, Shandong Agricultural University, Taian 271018, China.
| |
Collapse
|
3
|
Regiart M, Fernández-Baldo MA, Navarrete BA, Morales García C, Gómez B, Tortella GR, Valero T, Ortega FG. Five years of advances in electrochemical analysis of protein biomarkers in lung cancer: a systematic review. Front Chem 2024; 12:1390050. [PMID: 38764920 PMCID: PMC11099832 DOI: 10.3389/fchem.2024.1390050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 04/01/2024] [Indexed: 05/21/2024] Open
Abstract
Lung cancer is the leading cause of cancer death in both men and women. It represents a public health problem that must be addressed through the early detection of specific biomarkers and effective treatment. To address this critical issue, it is imperative to implement effective methodologies for specific biomarker detection of lung cancer in real clinical samples. Electrochemical methods, including microfluidic devices and biosensors, can obtain robust results that reduce time, cost, and assay complexity. This comprehensive review will explore specific studies, methodologies, and detection limits and contribute to the depth of the discussion, making it a valuable resource for researchers and clinicians interested in lung cancer diagnosis.
Collapse
Affiliation(s)
- Matías Regiart
- Instituto de Química San Luis (INQUISAL), Departamento de Química, Universidad Nacional de San Luis, CONICET, San Luis, Argentina
| | - Martín A. Fernández-Baldo
- Instituto de Química San Luis (INQUISAL), Departamento de Química, Universidad Nacional de San Luis, CONICET, San Luis, Argentina
| | - Bernardino Alcázar Navarrete
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
- CIBERES, Instituto de Salud Carlos III, Madrid, Spain
| | - Concepción Morales García
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
| | - Beatriz Gómez
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
| | - Gonzalo R. Tortella
- Centro de Excelencia en Investigación Biotecnológica Aplicada al Medio Ambiente (CIBAMA), Facultad de Ingeniería y Ciencias, Universidad de La Frontera, Temuco, Chile
- Departamento de Ingeniería Química, Facultad de Ingeniería y Ciencias, Universidad de La Frontera, Temuco, Chile
| | - Teresa Valero
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Department of Medicinal and Organic Chemistry and Excellence Research Unit of “Chemistry Applied to Biomedicine and the Environment”, Faculty of Pharmacy, University of Granada, Granada, Spain
| | - Francisco Gabriel Ortega
- IBS Granada, Institute of Biomedical Research, Granada, Spain
- Pulmonology Unit, Hospital Universitario Virgen de las Nieves, Granada, Spain
- GENYO, Centre for Genomics and Oncological Research, Pfizer/University of Granada/Andalusian Regional Government, Granada, Spain
- UGC Cartuja, Distrito Sanitario Granada Metropolitano, Granada, Spain
| |
Collapse
|
4
|
Cheng HP, Yang TH, Wang JC, Chuang HS. Recent Trends and Innovations in Bead-Based Biosensors for Cancer Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:2904. [PMID: 38733011 PMCID: PMC11086254 DOI: 10.3390/s24092904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024]
Abstract
Demand is strong for sensitive, reliable, and cost-effective diagnostic tools for cancer detection. Accordingly, bead-based biosensors have emerged in recent years as promising diagnostic platforms based on wide-ranging cancer biomarkers owing to the versatility, high sensitivity, and flexibility to perform the multiplexing of beads. This comprehensive review highlights recent trends and innovations in the development of bead-based biosensors for cancer-biomarker detection. We introduce various types of bead-based biosensors such as optical, electrochemical, and magnetic biosensors, along with their respective advantages and limitations. Moreover, the review summarizes the latest advancements, including fabrication techniques, signal-amplification strategies, and integration with microfluidics and nanotechnology. Additionally, the challenges and future perspectives in the field of bead-based biosensors for cancer-biomarker detection are discussed. Understanding these innovations in bead-based biosensors can greatly contribute to improvements in cancer diagnostics, thereby facilitating early detection and personalized treatments.
Collapse
Affiliation(s)
- Hui-Pin Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
| | - Tai-Hua Yang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Department of Orthopedic Surgery, National Cheng Kung University Hospital, Tainan 704, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| | - Jhih-Cheng Wang
- Department of Urology, Chimei Medical Center, Tainan 710, Taiwan
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan 710, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung 804, Taiwan
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
5
|
Özçelikay-Akyıldız G, Ünal MA, Atakan Ş, Gülden S, Kızılelma B, Aydın S, Ozkan SA. Ultrasensitive electrochemical immunosensor system for determination of autologous SOX2 antibody. J Pharm Biomed Anal 2024; 241:115992. [PMID: 38277708 DOI: 10.1016/j.jpba.2024.115992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/17/2024] [Accepted: 01/18/2024] [Indexed: 01/28/2024]
Abstract
Lung cancer is mainly seen as the cancer type in the world. Lung cancer causes the death of many people. It is classified as large-cell neuroendocrine carcinoma (LCNEC), small-cell lung cancer (SCLC), and adenocarcinoma by the World Health Organization (WHO) in 2015. Small cell lung cancer (SCLC) is a highly aggressive type of cancer, accounting for approximately 20% of all cases. By performing the serological analysis of expression cDNA libraries (SEREX), the humoral immune response of SCLC patients is determined. SEREX of SCLC cell lines using pooled sera of SCLC patients led to the isolation of SOX2 genes. The between SOX2 antigen expression intensity and autologous antibody presence has a significant correlation because SOX2 is the main antigen eliciting anti-SOX responses. Electrochemical biosensors take much attention because of their simplicity, selectivity, and sensitivity in clinical analysis. Antibody-based surface recognizes antibody-specific antigens. This work aims to fabricate an immunosensor for determining autologous SOX2 antibodies using a multi-walled carbon nanotube-modified screen-printed electrode (DRP-MWCNT). All immobilization processes were evaluated with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The critical parameters were optimized, such as EDC/NHS concentration and time, SOX2 protein concentration and incubation time, BSA ratio, BSA blocking time, and anti-SOX2 antibody incubation time. The developed immunosensor, under optimal conditions, shows a linear response of autologous SOX2 antibody between 0.005 ng.mL-1 and 0.1 ng.mL-1. The limit of detection and quantification were 0.001 and 0.004 ng.mL-1, respectively. The electrode morphologies were examined with a scanning electron microscope (SEM). Lastly, the developed immunosensor was applied to a synthetic serum sample, and the linear range was compared with enzyme-linked immunosorbent assay (ELISA).
Collapse
Affiliation(s)
- Göksu Özçelikay-Akyıldız
- Ankara University Faculty of Pharmacy, Department of Analytical Chemistry, Ankara 06560, Türkiye.
| | | | - Şükrü Atakan
- Bilkent University, Department of Molecular Biology and Genetics, Ankara 06800, Türkiye
| | - Seçil Gülden
- Bilkent University, Department of Neuroscience, Ankara 06800, Türkiye
| | | | | | - Sibel A Ozkan
- Ankara University Faculty of Pharmacy, Department of Analytical Chemistry, Ankara 06560, Türkiye.
| |
Collapse
|
6
|
Yılmaz M, Bilgi M. A disposable impedimetric immunosensor for the analysis of CA125 in human serum samples. Biomed Microdevices 2024; 26:8. [PMID: 38180587 DOI: 10.1007/s10544-023-00691-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2023] [Indexed: 01/06/2024]
Abstract
Cancer antigen 125 (CA125) is the most common biomarker used to diagnose and monitor ovarian cancer progression for the last four decades, and precise detection of its levels in blood serum is crucial. In this work, label-free impedimetric CA125 immunosensors were fabricated by using screen-printed carbon electrodes modified with poly toluidine blue (PTB) (in deep eutectic solvent)/gold nanoparticles (AuNP) for the sensitive, environmentally friendly, economical, and practical analysis of CA125. The materials of PTBDES and AuNP were characterized by Fourier Transform Infrared (FT-IR), Scanning Electron Microscope (FE-SEM), and X-ray Diffraction (XRD). The analysis of the CA125 was performed by electrochemical impedance spectroscopy and the developed immunosensor. The immunosensor's repeatability, reproducibility, reusability, selectivity, and storage stability were examined. The developed label-free immunosensor allowed the determination of CA125 in fast, good repeatability and a low limit of detection (1.20 pg mL-1) in the linear range of 5-100 pg mL-1. The stable surface of the fabricated immunosensor was successfully regenerated ten times. The application of immunosensors in commercial human blood serum was performed, and good recoveries were achieved. The disposable label-free impedimetric CA125 immunosensor developed for the rapid and practical detection of CA125 is a candidate for use in point-of-care tests in clinical applications of ovarian cancer.
Collapse
Affiliation(s)
- Merve Yılmaz
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye
| | - Melike Bilgi
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye.
| |
Collapse
|
7
|
Bilgi Kamaç M, Altun M, Yılmaz M, Yılmaz Aktan A, Aktan S, Sezgintürk MK. Point-of-care testing: a disposable label-free electrochemical CA125 and HE4 immunosensors for early detection of ovarian cancer. Biomed Microdevices 2023; 25:18. [PMID: 37140852 DOI: 10.1007/s10544-023-00659-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/29/2023] [Indexed: 05/05/2023]
Abstract
Cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are critical biomarkers for ovarian cancer diagnosis and progression monitoring; therefore, sensitive determination of their levels in body fluids is crucial. In recent study, label-free CA125 and HE4 immunosensors were prepared using disposable screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles for the sensitive, fast, and practical determination of CA125 and HE4. Differential pulse voltammetry, square wave voltammetry, and electrochemical impedance spectroscopy methods were used for the electrochemical determination of antigens in four different linear ranges (1-100 pg mL- 1, 0.01-10 ng mL- 1, 10-50 ng mL- 1, and 50-500 ng mL- 1). High sensitivity, low limit of detection, and limit of quantification were obtained for each linear range with a correlation coefficient above 0.99. The application stability of CA125 and HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. Immunosensors showed high selectivity in nine different antigen mixtures. The reusability of the immunosensors has been tested up to 9 cycles. The Risk of Ovarian Malignancy Algorithm score% values were calculated using the concentration of CA125 and HE4 in the blood serum and evaluated in terms of ovarian cancer risk. For the point-of-care testing, CA125 and HE4 levels at pg mL- 1 concentration were measured in blood serum samples using the developed immunosensors and a hand-held electrochemical reader in approximately 20-30 s, and high recoveries were obtained. These disposable label-free immunosensors are user-friendly and can be used in point-of-care tests for rapid and practical detection of CA125 and HE4 with high selectivity, sensitivity, and repeatability.
Collapse
Affiliation(s)
- Melike Bilgi Kamaç
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Turkey.
| | - Muhammed Altun
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Merve Yılmaz
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Ayla Yılmaz Aktan
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Soner Aktan
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
| |
Collapse
|
8
|
Bilgi Kamaç M, Altun M, Yilmaz M, Sezgintürk MK. A label-free dual immunosensor for the simultaneous electrochemical determination of CA125 and HE4 biomarkers for the early diagnosis of ovarian cancer. Anal Bioanal Chem 2023; 415:1709-1718. [PMID: 36719438 DOI: 10.1007/s00216-023-04569-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 02/01/2023]
Abstract
The blood levels of cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are measured in the diagnosis and progression monitoring of ovarian cancer (OC), and the Risk of Ovarian Malignancy Algorithm (ROMA) score% values are calculated for cancer risk assessment. For the first time, disposable dual screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles were used to fabricate label-free electrochemical dual CA125-HE4 immunosensors for the sensitive, fast, and practical simultaneous determination of CA125 and HE4. DPV and SWV methods were used to simultaneously determine antigens in two different linear ranges (1-100 pg mL-1 and 1-50 ng mL-1). High sensitivity, low LOD, and LOQ were obtained for two linear ranges with a correlation coefficient above 0.99. The application stability of the dual CA125-HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. The dual immunosensors exhibited high selectivity in eight different antigen mixtures. The reusability of the dual immunosensors has been tested up to 9 cycles. ROMA score% values for pre-menopausal and post-menopausal status were calculated using the concentration of CA125 and HE4 in the blood serum and assessing OC risk. The disposable dual immunosensors can be used in point-of-care tests for rapid and practical simultaneous determination of CA125 and HE4 with high selectivity, sensitivity, and repeatability.
Collapse
Affiliation(s)
- Melike Bilgi Kamaç
- Chemistry Department, Faculty of Science, Çankırı Karatekin University, Çankırı, 18100, Turkey.
| | - Muhammed Altun
- Chemistry Department, Faculty of Science, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Merve Yilmaz
- Chemistry Department, Faculty of Science, Çankırı Karatekin University, Çankırı, 18100, Turkey
| | - Mustafa Kemal Sezgintürk
- Bioengineering Department, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
| |
Collapse
|
9
|
Özyurt C, Uludağ İ, Sezgintürk MK. An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples. Anal Bioanal Chem 2023; 415:1123-1136. [PMID: 36155829 DOI: 10.1007/s00216-022-04309-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/22/2022] [Accepted: 08/29/2022] [Indexed: 02/07/2023]
Abstract
In this study, we constructed a disposable indium tin oxide polyethylene terephthalate film (ITO-PET)-based electrochemical aptasensor for analyzing prostate-specific antigen (PSA), one of the most important biomarkers of prostate cancer. Because of their clinical importance, building PSA biosensing systems with high sensitivity and stability is essential. However, it still presents significant difficulties, such as low detection limits. We designed a platform to covalently bind the amino-terminated aptamer by modifying the ITO-PET surface with carboxyethylsilanetriol (CTES) to obtain a self-assembled monolayer (SAM). We also evaluated the potential for use in real human serum samples by investigating the optimal operating conditions and analytical performance characteristics of the developed biosensor. The design we present here exhibits excellent precision, with a limit of detection (LOD) as low as 8.74 fg/mL PSA. The broad linear detection range of the biosensor under optimal conditions was determined as 1.0-1500 fg/mL. The dissociation constant (Kd) for the aptamer was also calculated as 46.28 ± 5.63 nM by evaluating the impedimetric response as a function of PSA concentration. The aptasensor displayed considerable repeatability (1.3% RSD) and reproducibility (7.51% RSD) and good storage stability (98.34% of the initial activity for 8 weeks). Additionally, we demonstrated that the technique we developed was quite efficient in estimating the kinetics of aptamer-analyte interactions by determining the Kd and single-frequency impedance (SFI) data. In conclusion, we proposed a selective and sensitive biosensor with the potential for clinical application and superior performance in real serum samples.
Collapse
Affiliation(s)
- Canan Özyurt
- Department of Chemistry and Chemical Processing Technologies, Lapseki Vocational School, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - İnci Uludağ
- Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Mustafa Kemal Sezgintürk
- Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
| |
Collapse
|
10
|
Rivas MV, Arenas Muñetón MJ, Bordoni AV, Lombardo MV, Spagnuolo CC, Wolosiuk A. Revisiting carboxylic group functionalization of silica sol-gel materials. J Mater Chem B 2023; 11:1628-1653. [PMID: 36752739 DOI: 10.1039/d2tb02279f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
The carboxylic chemical group is a ubiquitous moiety present in amino acids, a ligand for transition metals, a colloidal stabilizer, and a weak acidic ion-exchanger in polymeric resins and given this property, it is attractive for responsive materials or nanopore-based gating applications. As the number of uses increases, subtle requirements are imposed on this molecular group when anchored to various platforms for the functioning of an integrated chemical system. In this context, silica stands as an inert and multipurpose platform that enables the anchoring of multiple chemical entities combined through several orthogonal synthesis methods on the interface. Surface chemical modification relies on the use of organoalkoxysilanes that must meet the demand of tuned chemical properties; this, in turn, urges for innovative approaches for having an improved, but simple, organic toolbox. Starting from commonly available molecular precursors, several approaches have emerged: hydrosilylation, click thiol-ene additions, the use of carbodiimides or the reaction between cyclic anhydrides and anchored amines. In this review, we analyze the importance of the COOH groups in the area of materials science and the commercial availability of COOH-based silanes and present new approaches for obtaining COOH-based organoalkoxide precursors. Undoubtedly, this will attract widespread interest for the ultimate design of highly integrated chemical platforms.
Collapse
Affiliation(s)
- M Verónica Rivas
- Gerencia Química - Instituto de Nanociencia y Nanotecnología, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, CONICET, Av. Gral. Paz 1499, B1650KNA San Martín, Buenos Aires, Argentina. .,Departamento de Química Orgánica, Universidad de Buenos Aires, Facultad de Ciencias Exactas y Naturales, Buenos Aires, Argentina
| | - María J Arenas Muñetón
- Gerencia Química - Instituto de Nanociencia y Nanotecnología, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, CONICET, Av. Gral. Paz 1499, B1650KNA San Martín, Buenos Aires, Argentina.
| | - Andrea V Bordoni
- Gerencia Química - Instituto de Nanociencia y Nanotecnología, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, CONICET, Av. Gral. Paz 1499, B1650KNA San Martín, Buenos Aires, Argentina.
| | - M Verónica Lombardo
- Gerencia Química - Instituto de Nanociencia y Nanotecnología, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, CONICET, Av. Gral. Paz 1499, B1650KNA San Martín, Buenos Aires, Argentina.
| | - Carla C Spagnuolo
- Departamento de Química Orgánica, Universidad de Buenos Aires, Facultad de Ciencias Exactas y Naturales, Buenos Aires, Argentina
| | - Alejandro Wolosiuk
- Gerencia Química - Instituto de Nanociencia y Nanotecnología, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, CONICET, Av. Gral. Paz 1499, B1650KNA San Martín, Buenos Aires, Argentina.
| |
Collapse
|
11
|
Current Update on Biomarkers for Detection of Cancer: Comprehensive Analysis. Vaccines (Basel) 2022; 10:vaccines10122138. [PMID: 36560548 PMCID: PMC9787556 DOI: 10.3390/vaccines10122138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/27/2022] [Accepted: 11/23/2022] [Indexed: 12/15/2022] Open
Abstract
Early and effective diagnosis of cancer is decisive for its proper management. In this context biomarker-based cancer diagnosis is budding as one of the promising ways for early detection, disease progression monitoring, and effective cancer therapy. Integration of Biosensing devices with different metallic/nonmetallic nanoparticles offers amplification and multiplexing capabilities for simultaneous detection of cancer biomarkers (CB's). This study provides a comprehensive analysis of the most recent designs and fabrication methodologies designed for developing electrochemical biosensors (EB) for early detection of cancers. The role of biomarkers in cancer therapeutics is also discussed.
Collapse
|
12
|
BRITO FAED, FURTADO RF, BEZERRA LCR, FIGUEIREDO EATD, MELO AMA, ALVES CR, CHENG HN, BISWAS A. Effect of time and storage condition on the performance of an electrochemical immunosensor for Salmonella. FOOD SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1590/fst.91621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Affiliation(s)
| | | | | | | | | | | | | | - Atanu BISWAS
- National Center for Agricultural Utilization Research, USA
| |
Collapse
|
13
|
Suni II. Substrate Materials for Biomolecular Immobilization within Electrochemical Biosensors. BIOSENSORS 2021; 11:239. [PMID: 34356710 PMCID: PMC8301891 DOI: 10.3390/bios11070239] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 07/01/2021] [Accepted: 07/08/2021] [Indexed: 01/17/2023]
Abstract
Electrochemical biosensors have potential applications for agriculture, food safety, environmental monitoring, sports medicine, biomedicine, and other fields. One of the primary challenges in this field is the immobilization of biomolecular probes atop a solid substrate material with adequate stability, storage lifetime, and reproducibility. This review summarizes the current state of the art for covalent bonding of biomolecules onto solid substrate materials. Early research focused on the use of Au electrodes, with immobilization of biomolecules through ω-functionalized Au-thiol self-assembled monolayers (SAMs), but stability is usually inadequate due to the weak Au-S bond strength. Other noble substrates such as C, Pt, and Si have also been studied. While their nobility has the advantage of ensuring biocompatibility, it also has the disadvantage of making them relatively unreactive towards covalent bond formation. With the exception of Sn-doped In2O3 (indium tin oxide, ITO), most metal oxides are not electrically conductive enough for use within electrochemical biosensors. Recent research has focused on transition metal dichalcogenides (TMDs) such as MoS2 and on electrically conductive polymers such as polyaniline, polypyrrole, and polythiophene. In addition, the deposition of functionalized thin films from aryldiazonium cations has attracted significant attention as a substrate-independent method for biofunctionalization.
Collapse
Affiliation(s)
- Ian Ivar Suni
- Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, USA; ; Tel.: +1-618-453-7822
- School of Chemistry and Biomolecular Sciences, Southern Illinois University, Carbondale, IL 62901, USA
- School of Mechanical, Aerospace and Materials Engineering, Southern Illinois University, Carbondale, IL 62901, USA
| |
Collapse
|
14
|
Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum. Talanta 2021; 222:121487. [DOI: 10.1016/j.talanta.2020.121487] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 07/20/2020] [Accepted: 07/29/2020] [Indexed: 02/07/2023]
|
15
|
Aydın EB, Aydın M, Sezgintürk MK. A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode. J Pharm Biomed Anal 2020; 190:113517. [PMID: 32784093 DOI: 10.1016/j.jpba.2020.113517] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/27/2020] [Accepted: 07/27/2020] [Indexed: 11/19/2022]
Abstract
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was used as an immobilization matrix for construction of RACK 1 immunosensor. This polymer had a great number of carboxyl groups on its end site and these carboxyl ends provided anchoring points to the anti-RACK 1 antibodies. Anti-RACK 1 antibodies were covalently attached on the ITO electrode and recognized the RACK 1 antigens. Electrochemical characterizations were made by employing electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Additionally, single frequency impedance method (SFI) was applied to follow the specific biointeraction between antibody and antigen. As a result of specific biointeraction, the designed immunosensor exhibited a wide linear detection range between 0.01 pg/mL and 2 pg/mL RACK 1 with a detection limit of 3.1 fg/mL. Scanning electron microscopy and atomic force microscopy analyses were employed for electrode surface morphology investigation. The designed RACK 1 biosensor had good repeatability (5.73 %, RSD), excellent reproducibility (2.5 %, RSD), long storage-stability and reusable property. In addition, the fabricated RACK 1 biosensor was applied to determine RACK 1 concentration in human serums and the recovery was ranging from 98.79%-100.22%. This work illustrated a new tool to construct a sensitive and low-cost disposable biosensor for applications in clinical monitoring.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Muhammet Aydın
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey.
| |
Collapse
|
16
|
Abstract
In recent years, advances in immunosensor device fabrication have significantly expanded the use of this technology in a broad range of applications including clinical diagnosis, food analysis, quality control, environmental studies and industrial monitoring. The most important aspect in fabrication is to obtain a design that provides a low detection limit. The utilization of nanomaterials as a label, catalyst and biosensing transducer is, perhaps, the most popular approach in ultrasensitive devices. This chapter reviews recent advances in immunosensor fabrication and summarizes the most recent studies. Strategies employed to significantly improve sensitivity and specificity of immunosensor technology and the advantages and limitations thereof are explored.
Collapse
Affiliation(s)
- Muhammet Aydin
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey.
| | - Elif Burcu Aydin
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Bioengineering Department, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| |
Collapse
|
17
|
Cordeiro TAR, Martins HR, Franco DL, Santos FLN, Celedon PAF, Cantuária VL, de Lana M, Reis AB, Ferreira LF. Impedimetric immunosensor for rapid and simultaneous detection of chagas and visceral leishmaniasis for point of care diagnosis. Biosens Bioelectron 2020; 169:112573. [PMID: 32905944 DOI: 10.1016/j.bios.2020.112573] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 08/25/2020] [Accepted: 08/28/2020] [Indexed: 02/08/2023]
Abstract
In this work, a dual detection system based on an impedimetric immunosensor was developed for the first time for the simultaneous detection of anti-Trypanosoma cruzi and anti-Leishmania infantum antibodies in human and dog serum samples. The IBMP 8.1 and rLci1A/rLci2B recombinant antigens were immobilized over the surface of dual screen-printed carbon electrodes (W1 and W2) modified with poly (4-hydroxyphenylacetic acid). Under optimized conditions, the immunosensor recognized specific interactions for anti-T. cruzi antibodies up to a dilution of 1:10,240 and for anti-L. infantum up to 1:5120 in canine serum samples. Relative standard deviation (RSD) values of 2.8% for W1 and 3.6% for W2 were obtained for T. cruzi (W1) and L. infantum antigen (W2) samples in three different electrodes for 3 days (n = 9). The immunosensor was stored at 4 °C for 8 weeks, with activity retention of 70.2% in W1 and 78.2% in W2. The results using the recombinant proteins revealed that all antigens discriminated between negative and positive samples (p < 0.0001) in both dog and human groups, as well as no cross-reactivity could be detected among sera with other infections. With this approach, immunosensor-based diagnostic tests achieved 100% accuracy, suggesting that the antigens are eligible to enter Phase-II studies.
Collapse
Affiliation(s)
- Taís Aparecida Reis Cordeiro
- Institute of Science and Technology, Laboratory of Electrochemistry and Applied Nanotechnology, Federal University of the Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil
| | - Helen Rodrigues Martins
- Department of Pharmacy, Federal University of the Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil
| | - Diego Leoni Franco
- Institute of Chemistry, Group of Electrochemistry Applied to Polymers and Sensors, Laboratory of Electroanalytical Applied to Biotechnology and Food Engineering, Federal University of Uberlândia, Patos de Minas, Minas Gerais, Brazil
| | - Fred Luciano Neves Santos
- Advanced Laboratory of Public Health, Gonçalo Moniz Institute (IGM), FIOCRUZ-BA, Salvador, Bahia, Brazil
| | | | - Vinícius Lopes Cantuária
- Department of Pharmacy, Federal University of the Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil
| | - Marta de Lana
- Department of Clinical Analysis, School of Pharmacy, Federal University of Ouro Preto, Ouro Preto, Minas Gerais, Brazil
| | - Alexandre Barbosa Reis
- Department of Clinical Analysis, School of Pharmacy, Federal University of Ouro Preto, Ouro Preto, Minas Gerais, Brazil
| | - Lucas Franco Ferreira
- Institute of Science and Technology, Laboratory of Electrochemistry and Applied Nanotechnology, Federal University of the Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil.
| |
Collapse
|
18
|
Aydın EB. Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode. Talanta 2020; 215:120909. [DOI: 10.1016/j.talanta.2020.120909] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/04/2020] [Accepted: 03/07/2020] [Indexed: 12/25/2022]
|
19
|
Regiart M, Gimenez AM, Lopes AT, Carreño MNP, Bertotti M. Ultrasensitive microfluidic electrochemical immunosensor based on electrodeposited nanoporous gold for SOX-2 determination. Anal Chim Acta 2020; 1127:122-130. [PMID: 32800115 DOI: 10.1016/j.aca.2020.06.037] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 06/10/2020] [Accepted: 06/15/2020] [Indexed: 01/06/2023]
Abstract
An ultrasensitive and portable microfluidic electrochemical immunosensor for SOX-2 cancer biomarker determination was developed. The selectivity and sensitivity of the sensor were improved by modifying the microfluidic channel. This was accomplished through a physical-chemical treatment to produce a hydrophilic surface, with an increased surface to volume/ratio, where the anti-SOX-2 antibodies can be covalently immobilized. A sputtered gold electrode was used as detector and its surface was activated by using a dynamic hydrogen bubble template method. As a result, a gold nanoporous structure (NPAu) with outstanding properties, like high specific surface area, large pore volume, uniform nanostructure, good conductivity, and excellent electrochemical activity was obtained. SOX-2 present in the sample was bound to the anti-SOX-2 immobilized in the microfluidic channel, and then was labeled with a second antibody marked with horseradish peroxidase (HRP-anti-SOX-2) like a sandwich immunoassay. Finally, an H2O2 + catechol solution was added, and the enzymatic product (quinone) was reduced on the NPAu electrode at +0.1 V (vs. Ag). The current obtained was directly proportional to the SOX-2 concentration in the sample. The detection limit achieved was 30 pg mL-1, and the coefficient of variation was less than 4.75%. Therefore, the microfluidic electrochemical immunosensor is a suitable clinical device for in situ SOX-2 determination in real samples.
Collapse
Affiliation(s)
- Matías Regiart
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes 748, 05508-000, São Paulo, SP, Brazil
| | - Alba Marina Gimenez
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, 05508-000, São Paulo, SP, Brazil
| | - Alexandre T Lopes
- Department of Electronic Systems Engineering, Polytechnic School, University of São Paulo, 05508-010, São Paulo, SP, Brazil
| | - Marcelo N P Carreño
- Department of Electronic Systems Engineering, Polytechnic School, University of São Paulo, 05508-010, São Paulo, SP, Brazil
| | - Mauro Bertotti
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes 748, 05508-000, São Paulo, SP, Brazil.
| |
Collapse
|
20
|
Zhang Z, Li Q, Du X, Liu M. Application of electrochemical biosensors in tumor cell detection. Thorac Cancer 2020; 11:840-850. [PMID: 32101379 PMCID: PMC7113062 DOI: 10.1111/1759-7714.13353] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 01/19/2020] [Accepted: 01/21/2020] [Indexed: 01/05/2023] Open
Abstract
Conventional methods for detecting tumors, such as immunological methods and histopathological diagnostic techniques, often request high analytical costs, complex operation, long turnaround time, experienced personnel and high false-positive rates. In addition, these assays are difficult to obtain an early diagnosis and prognosis quickly for malignant tumors. Compared with traditional technology, electrochemical technology has realized the study of interface charge transfer behavior at the atomic and molecular levels, which has become an important analytical and detection tool in contemporary analytical science. Electrochemical technique has the advantages of rapid detection, high sensitivity (single cell) and specificity in the detection of tumor cells, which has not only been successful in differentiating tumor cells from normal cells, but has also achieved targeted detection of localized tumor cells and circulating tumor cells. Electrochemical biosensors provide powerful tools for early diagnosis, staging and prognosis of tumors in clinical medicine. Therefore, this review mainly discusses the development and application of electrochemical biosensors in tumor cell detection in recent years.
Collapse
Affiliation(s)
- Zhenhua Zhang
- Institute of Biomedical Sciences, Shandong Provincial Key Laboratory of Animal Resistance Biology, Collaborative Innovation Center of Cell Biology in Universities of Shandong, College of Life SciencesShandong Normal UniversityJinanChina
| | - Qingchao Li
- Institute of Biomedical Sciences, Shandong Provincial Key Laboratory of Animal Resistance Biology, Collaborative Innovation Center of Cell Biology in Universities of Shandong, College of Life SciencesShandong Normal UniversityJinanChina
| | - Xin Du
- Institute of Biomedical Sciences, Shandong Provincial Key Laboratory of Animal Resistance Biology, Collaborative Innovation Center of Cell Biology in Universities of Shandong, College of Life SciencesShandong Normal UniversityJinanChina
| | - Min Liu
- Institute of Biomedical Sciences, Shandong Provincial Key Laboratory of Animal Resistance Biology, Collaborative Innovation Center of Cell Biology in Universities of Shandong, College of Life SciencesShandong Normal UniversityJinanChina
| |
Collapse
|
21
|
Blood-Based SOX2-Promoter Methylation in Relation to Exercise and PM 2.5 Exposure among Taiwanese Adults. Cancers (Basel) 2020; 12:cancers12020504. [PMID: 32098209 PMCID: PMC7072405 DOI: 10.3390/cancers12020504] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 02/20/2020] [Accepted: 02/20/2020] [Indexed: 01/12/2023] Open
Abstract
Increased ventilation during exercise in polluted areas could trigger airway inflammation. We evaluated blood DNA methylation of the SOX2-promoter region in relation to exercise and PM2.5 in Taiwanese adults. Data of 948 participants aged 30–70 years were retrieved from the Taiwan Biobank Database (2008–2015) and the Air Quality Monitoring Database (2006–2011). PM2.5 was positively associated with SOX2-promoter methylation (β = 0.000216; p < 0.0001). The interaction between PM2.5 and exercise on SOX2-promoter methylation was significant (p = 0.0146). After stratification by exercise habits, PM2.5 was positively associated with SOX2 methylation in only individuals who did regular exercise (β = 0.0003490; p < 0.0001). After stratification by exercise habits and residential areas, SOX2-promoter methylation levels in those who lived in the southern area were higher for both the regular exercise (β = 0.00272; p = 0.0172) and no regular exercise groups (β = 0.002610 and p = 0.0162). SOX2-promoter methylation levels in those who lived in the northern area and did regular exercise were lower; β = -0.00314 (p = 0.0036). In conclusion, PM2.5 was positively associated with SOX2-promoter methylation in participants who did regular exercise. Living in the southern area was positively associated with SOX2-promoter methylation regardless of exercise habits.
Collapse
|
22
|
Tarimeri N, Sezgintürk MK. A High Sensitive, Reproducible and Disposable Immunosensor for Analysis of SOX2. ELECTROANAL 2020. [DOI: 10.1002/elan.201900557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Nur Tarimeri
- Ege University, Faculty of Engineering Bioengineering Department İzmir Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering Bioengineering Department Çanakkale Turkey
| |
Collapse
|
23
|
Augustine S, Kumar P, Malhotra BD. Amine-Functionalized MoO3@RGO Nanohybrid-Based Biosensor for Breast Cancer Detection. ACS APPLIED BIO MATERIALS 2019; 2:5366-5378. [DOI: 10.1021/acsabm.9b00659] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Shine Augustine
- Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi, 110042 India
| | - Pragati Kumar
- Administrative Supervisor, Department of Electrical Engineering, Delhi Technological University, Delhi, 110042 India
| | - Bansi D. Malhotra
- Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi, 110042 India
| |
Collapse
|
24
|
Khanmohammadi A, Aghaie A, Vahedi E, Qazvini A, Ghanei M, Afkhami A, Hajian A, Bagheri H. Electrochemical biosensors for the detection of lung cancer biomarkers: A review. Talanta 2019; 206:120251. [PMID: 31514848 DOI: 10.1016/j.talanta.2019.120251] [Citation(s) in RCA: 177] [Impact Index Per Article: 35.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/08/2019] [Accepted: 08/09/2019] [Indexed: 01/05/2023]
Abstract
Cancer is one of the most widespread challenges and important diseases, which has the highest mortality rate. Lung cancer is the most common type of cancer, so that about 25% of all cancer deaths are related to the lung cancer. The lung cancer is classified as two different types with different treatment methodology: the small cell lung carcinoma and nonsmall cell lung carcinoma are two categories of the lung cancer. Since the lung cancer is often in the latent period in its early stages, therefore, early diagnosis of lung cancer has many challenges. Hence, there is a need for sensitive and reliable tools for preclinical diagnosis of lung cancer. Therefore, many detection methods have been employed for early detection of lung cancer. As lung cancer tumors growth in the body, the cancerous cells release numerous DNA, proteins, and metabolites as special biomarkers of the lung cancer. The levels of these biomarkers show the stages of the lung cancer. Therefore, detection of the biomarkers can be used for screening and clinical diagnosis of the lung cancer. There are numerous biomarkers for the lung cancer such as EGFR, CEA, CYFRA 21-1, ENO1, NSE, CA 19-9, CA 125 and VEGF. Nowadays, electrochemical methods are very attractive and useful in the lung cancer detections. So, in this paper, the recent advances and improvements (2010-2018) in the electrochemical detection of the lung cancer biomarkers have been reviewed.
Collapse
Affiliation(s)
- Akbar Khanmohammadi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Aghaie
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ensieh Vahedi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Qazvini
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Mostafa Ghanei
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Vienna, Austria
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
25
|
Anu Prathap MU, Castro-Pérez E, Jiménez-Torres JA, Setaluri V, Gunasekaran S. A flow-through microfluidic system for the detection of circulating melanoma cells. Biosens Bioelectron 2019; 142:111522. [PMID: 31336226 DOI: 10.1016/j.bios.2019.111522] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Revised: 07/03/2019] [Accepted: 07/16/2019] [Indexed: 12/19/2022]
Abstract
We report the fabrication of polyaniline nanofiber (PANI)-modified screen-printed electrode (PANI/SPE) incorporated in a poly-dimethylsiloxane (PDMS) microfluidic channel for the detection of circulating tumor cells. We employed this device to detect melanoma skin cancer cells through specific immunogenic binding of cell surface biomarker melanocortin 1 receptor (MC1R) to anti-MC1R antibody. The antibody-functionalized PANI/SPE was used in batch-continuous flow-through fashion. An aqueous cell suspension of ferri/ferrocyanide at a flow rate of 1.5 mL/min was passed over the immunosensor, which allowed for continuous electrochemical measurements. The sensor performed exceptionally well affording an ultralow limit of quantification of 1 melanoma cell/mL, both in buffer and when mixed with peripheral blood mononuclear cells, and the response was log-linear over the range of 10-9000 melanoma cells/10 mL.
Collapse
Affiliation(s)
| | - Edgardo Castro-Pérez
- Department of Dermatology, School of Medicine and Public Health, University of Wisconsin-Madison, 1300 University Avenue, Madison, WI, 53706, USA
| | - José A Jiménez-Torres
- Microtechnology, Medicine and Biology Lab Biomedical Engineering, College of Engineering University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Vijaysaradhi Setaluri
- Department of Dermatology, School of Medicine and Public Health, University of Wisconsin-Madison, 1300 University Avenue, Madison, WI, 53706, USA.
| | - Sundaram Gunasekaran
- Department of Biological Systems Engineering, University of Wisconsin-Madison, 460 Henry Mall, Madison, WI, 53706, USA.
| |
Collapse
|
26
|
Aydın M, Aydın EB, Sezgintürk MK. A Highly Selective Poly(thiophene)‐graft‐Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum. Macromol Biosci 2019; 19:e1900109. [DOI: 10.1002/mabi.201900109] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 05/31/2019] [Indexed: 01/01/2023]
Affiliation(s)
- Muhammet Aydın
- Tekirdagˇ Namık Kemal UniversityScientific and Technological Research Center Tekirdagˇ 59000 Turkey
| | - Elif Burcu Aydın
- Tekirdagˇ Namık Kemal UniversityScientific and Technological Research Center Tekirdagˇ 59000 Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart UniversityFaculty of Engineering, Bioengineering Department Çanakkale 17000 Turkey
| |
Collapse
|
27
|
Özcan B, Sezgintürk MK. Highly sensitive and cost-effective ITO-based immunosensor system modified by 11-CUTMS: Analysis of SOX2 protein in real human serum. Int J Biol Macromol 2019; 130:245-252. [DOI: 10.1016/j.ijbiomac.2019.02.112] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 02/19/2019] [Accepted: 02/19/2019] [Indexed: 12/29/2022]
|
28
|
Abstract
Immunosensors are compact tools on which antibody and antigen interactions are formed. The specific interaction between antibody and antigen is detected by using a transducer and an electrical signal is measured. This specific interaction between these molecules makes immunosensor very attractive for several applications in different fields. Electrochemical immunosensors are successful devices in selective and sensitive detection of several analytes. Electrochemical transducing methods such as voltammetric, potentiometric, conductometric or impedimetric have been utilized in different applications due to their excellent properties such as being low-cost, sensitivity and simplicity. In this chapter, the fundamentals of electrochemical immunosensors are summarized and different applications in food, environmental and clinical analyses are investigated and discussed.
Collapse
Affiliation(s)
- Elif Burcu Aydin
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey.
| | - Muhammet Aydin
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| |
Collapse
|
29
|
Cordeiro TA, Gonçalves MV, Franco DL, Reis AB, Martins HR, Ferreira LF. Label-free electrochemical impedance immunosensor based on modified screen-printed gold electrodes for the diagnosis of canine visceral leishmaniasis. Talanta 2019; 195:327-332. [DOI: 10.1016/j.talanta.2018.11.087] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2018] [Revised: 11/22/2018] [Accepted: 11/22/2018] [Indexed: 01/01/2023]
|
30
|
Novel electrochemical sensing platform based on a nanocomposite of PVA/PVP/RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation. Talanta 2019; 195:699-705. [DOI: 10.1016/j.talanta.2018.11.070] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Revised: 11/16/2018] [Accepted: 11/21/2018] [Indexed: 11/19/2022]
|
31
|
Aydın EB, Aydın M, Sezgintürk MK. Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection. Biosens Bioelectron 2018; 121:80-89. [DOI: 10.1016/j.bios.2018.09.008] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 08/26/2018] [Accepted: 09/01/2018] [Indexed: 10/28/2022]
|
32
|
A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1β in human serum and saliva. Anal Chim Acta 2018; 1039:41-50. [DOI: 10.1016/j.aca.2018.07.055] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Revised: 07/19/2018] [Accepted: 07/23/2018] [Indexed: 01/11/2023]
|
33
|
Aydın M, Aydın EB, Sezgintürk MK. A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva. Biosens Bioelectron 2018; 117:720-728. [DOI: 10.1016/j.bios.2018.07.010] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 07/04/2018] [Accepted: 07/09/2018] [Indexed: 01/20/2023]
|
34
|
Haji-Hashemi H, Norouzi P, Safarnejad MR, Larijani B, Habibi MM, Raeisi H, Ganjali MR. Sensitive electrochemical immunosensor for citrus bacterial canker disease detection using fast Fourier transformation square-wave voltammetry method. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.04.062] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
35
|
Aydın EB, Sezgintürk MK. An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications. Anal Biochem 2018; 554:44-52. [PMID: 29902421 DOI: 10.1016/j.ab.2018.05.030] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 05/27/2018] [Accepted: 05/30/2018] [Indexed: 11/30/2022]
Abstract
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first employed to cancer biomarker sensing platform. Anti-IL-8 antibody was used as a biorecognition element and the detection principle of this immunosensor was based on monitoring specific interaction between anti-IL-8 antibody and IL-8 antigen. The morphological characterization of each electrode modification step was analyzed by scanning electron microscopy (SEM), SEM-energy dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM) while electrochemical characterization was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and single frequency impedance (SFI) techniques. Moreover, the antibody immobilization on the electrode surface was proved Fourier-transform infrared spectroscopy (FTIR) and Raman Spectroscopy. This proposed impedimetric immunosensor exhibited good performances with a wide linear in the range from 0.02 pg/mL to 3 pg/mL as well as a relative low detection limit of 6 fg/mL. The impedimetric immunosensor had a good specificity, stability and reproducibility. This study proved that PHA was a suitable interface material to fabricate an electrochemical biosensor.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey.
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| |
Collapse
|
36
|
Aydın M, Aydın EB, Sezgintürk MK. A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum. Biosens Bioelectron 2018; 107:1-9. [DOI: 10.1016/j.bios.2018.02.017] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 01/05/2018] [Accepted: 02/04/2018] [Indexed: 11/26/2022]
|
37
|
Törer H, Aydın EB, Sezgintürk MK. A label-free electrochemical biosensor for direct detection of RACK 1 by using disposable, low-cost and reproducible ITO based electrode. Anal Chim Acta 2018; 1024:65-72. [PMID: 29776548 DOI: 10.1016/j.aca.2018.04.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 03/29/2018] [Accepted: 04/05/2018] [Indexed: 02/08/2023]
Abstract
In this study we designed an ultrasensitive electrochemical immunosensor for RACK 1 detection using 11-cyanoundecyltrimethoxysilane (11-CUTMS) as a immobilization matrix to immobilize biorecognition element. The used silane agent (11-CUTMS) provides a favorable platform for efficient loading of anti-RACK 1 antibody. The effective loading of the biorecognition element on the 11-CUTMS matrix was monitored by scanning electron microscopy (SEM), atomic force microscopy (AFM) images and fourier transform infrared spectroscopy (FTIR) spectra. The electrochemical characterization of the immunosensor was performed by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Moreover, biorecognition interaction between anti-RACK1 antibodies and RACK1 antigens was monitored by using single frequency technique (SFI). The operating conditions, calibration curves obtained during optimization of experiments and reproducibility of the proposed impedimetric RACK1 biosensor are also investigated and discussed. The electrochemical immunosensor illustrated a sensitive response to RACK 1 antigen with detection limit of 10.8 fg/mL and in the linear range of 0.036-2.278 pg/mL (R2 = 0.999). Owing to high specificity, good reproducibility, long stability and reusability, the fabricated immunosensor will provide a sensitive, selective approach to RACK 1 detection. Furthermore, the practical applicability in human serum samples were investigated with a satisfactory result.
Collapse
Affiliation(s)
- Hakan Törer
- Namık Kemal University, Faculty or Arts and Sciences, Chemistry Department, Tekirdağ, Turkey
| | - Elif Burcu Aydın
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey.
| |
Collapse
|
38
|
Prathap MUA, Rodríguez CI, Sadak O, Guan J, Setaluri V, Gunasekaran S. Ultrasensitive electrochemical immunoassay for melanoma cells using mesoporous polyaniline. Chem Commun (Camb) 2018; 54:710-714. [PMID: 29299559 DOI: 10.1039/c7cc09248b] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
We report the development of an antibody (anti-MC1R antibody)-functionalized polyaniline nanofibers modified screen-printed electrode capable of efficient electrochemical detection of melanoma cells at levels (1 cell per mL) not readily achieved by other methods. This immunosensor is highly selective in its detection of melanoma cells over normal human cells.
Collapse
Affiliation(s)
- M U Anu Prathap
- Department of Biological Systems Engineering, University of Wisconsin-Madison, 460 H Mall, Madison, WI 53706, USA.
| | | | | | | | | | | |
Collapse
|
39
|
Aydın EB, Sezgintürk MK. Indium tin oxide (ITO): A promising material in biosensing technology. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.09.021] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
40
|
Alarfaj NA, El-Tohamy MF. A label-free electrochemical immunosensor based on gold nanoparticles and graphene oxide for the detection of tumor marker calcitonin. NEW J CHEM 2017. [DOI: 10.1039/c7nj01541k] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A label-free ultrasensitive electrochemical immunosensor has been designed for the detection of calcitonin, a medullary thyroid carcinoma tumor marker.
Collapse
Affiliation(s)
- Nawal A. Alarfaj
- Department of Chemistry
- College of Science
- King Saud University
- Riyadh 11495
- Saudi Arabia
| | - Maha F. El-Tohamy
- Department of Chemistry
- College of Science
- King Saud University
- Riyadh 11495
- Saudi Arabia
| |
Collapse
|