1
|
Liu R, Zhang C, Wu T, Liu R, Sun Y, Ma J. Fabrication of a novel HKUST-1/CoFe 2O 4/g-C 3N 4 electrode for the electrochemical detection of ciprofloxacin in physiological samples. Talanta 2024; 273:125882. [PMID: 38513472 DOI: 10.1016/j.talanta.2024.125882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 03/02/2024] [Accepted: 03/06/2024] [Indexed: 03/23/2024]
Abstract
In this work, a novel HKUST-1/CoFe2O4/g-C3N4 electrode was successfully prepared via the hydrothermal method and the high-temperature calcination method, which can be applied as an electrochemical sensor for the precise detection of ciprofloxacin (CIP) in physiological samples. The novel electrode was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FT-IR), and its electrochemical performance was further evaluated via the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The results demonstrated that the HKUST-1/CoFe2O4/g-C3N4 electrode exhibited an optimal linear range of 0.05-180 μmol L-1 for the CIP detection, which demonstrated a low limit of detection (LOD) of 0.0026 μmol L-1 and a low limit of quantitation (LOQ) of 0.0087 μmol L-1, respectively. Additionally, the novel semiconductor sensors exhibited exceptional selectivity, stability and repeatability in the determination of CIP. The recovery rate of CIP was found to range from 98.00% to 104.00% in serum, with the relative standard deviations (RSD) below 2.62% (n = 5), while the recovery rate of CIP was found to range from 96.00% to 105.00%, with the RSD less than 3.23% (n = 5) in urine. The current study extends to the application of the semiconductor-based electrochemical sensors and offers a new approach for the clinical pharmaceutical analysis to ensure medication safety, which could provide valuable insights into the potential of semiconductor sensors for future clinical applications.
Collapse
Affiliation(s)
- Rui Liu
- Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China.
| | - Chaojun Zhang
- Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China
| | - Tianheng Wu
- Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China
| | - Rijia Liu
- Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China
| | - Yuan Sun
- Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China.
| | - Jing Ma
- Department of Chemical Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
| |
Collapse
|
2
|
Manousi N, Anthemidis A. A continuous flow polyurethane foam solid phase microextraction lab-in-syringe platform for the automatic determination of toxic metals. Talanta 2024; 269:125492. [PMID: 38042142 DOI: 10.1016/j.talanta.2023.125492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/21/2023] [Accepted: 11/24/2023] [Indexed: 12/04/2023]
Abstract
A novel fully automatic continuous flow polyurethane foam solid phase microextraction lab-in-syringe system for on-line sample preconcentration/separation has been developed as a front-end to flame atomic absorption spectrometry. For the first time lab-in-syringe in continuous flow has been adopted for the determination of toxic metals. The microextraction procedure was performed after on-line metal complexation with ammonium pyrrolidine dithiocarbamate, while the elution was conducted by 400 μL of methyl isobutyl ketone. The main chemical and hydrodynamic factors that affected the performance of the method were optimized using Cd and Pb as model analytes. For 90 s preconcentration time, the limits of the detection were 0.20 and 1.7 μg L-1 for Cd and Pb, respectively, while the enhancement factors were 79 for Cd and 150 for Pb. The relative standard deviation% values were lower than 2.8 % for all analytes. As a proof-of-concept the proposed system was used for environmental water analysis, providing relative recoveries within the range of 94.0 and 104.4 %. The Green Analytical Procedure Index and Blue Applicability Grade Index proved reduced environmental impact and high practicality for the proposed method.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Aristidis Anthemidis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| |
Collapse
|
3
|
Yıldırım S, Karabulut SN, Çiçek M, Horstkotte B. Deep eutectic solvent-based ferrofluid for vortex-assisted liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs from environmental waters. Talanta 2024; 268:125372. [PMID: 37952315 DOI: 10.1016/j.talanta.2023.125372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/26/2023] [Accepted: 10/29/2023] [Indexed: 11/14/2023]
Abstract
A novel ferrofluid of Fe3O4 nanoparticles and a deep eutectic solvent (DES) composed of menthol and pentanoic acid was introduced as a green microextraction medium. The ferrofluid was successfully used as an extractant for vortex-assisted liquid-liquid microextraction (VALLME) of nonsteroidal anti-inflammatory drugs (NSAIDs) in environmental waters prior to their determination by HPLC-DAD. Once the ferrofluid was dispersed in the sample by vortex agitation, phase separation could be easily achieved by placing a neodymium magnet next to the tube, which eliminated the centrifugation step and simplified the operational procedure. As a result, the sample pretreatment took only ≈2 min. The experimental parameters, including pH, nanoparticle amount, ferrofluid volume, vortex time, salt amount, and disruptive solvent type and its volume, were optimized stepwise. The method showed linear behavior for all NSAIDs from 5 to 100 μg/L, with limit of detection values and enrichment factors in the ranges of 1.68-2.05 μg/L and 38.9-50.6, respectively. Intra- and Inter-day accuracies obtained from the analysis of spiked river, lake, and tap water samples at low and high-quality control levels (20 and 80 μg/L) ranged from 90.3% to 108.0%, with relative standard deviations less than <12.3%. The results of this study demonstrate that the use of DES-based ferrofluid in VALLME can be considered a simple, environmentally friendly, and reliable alternative for the determination of NSAIDs in environmental waters.
Collapse
Affiliation(s)
- Sercan Yıldırım
- Karadeniz Technical University, Faculty of Pharmacy, Department of Analytical Chemistry, Farabi Street, 61080, Trabzon, Turkey.
| | - Sema Nur Karabulut
- Karadeniz Technical University, Faculty of Pharmacy, Department of Analytical Chemistry, Farabi Street, 61080, Trabzon, Turkey
| | - Mükafat Çiçek
- Karadeniz Technical University, Faculty of Pharmacy, Department of Analytical Chemistry, Farabi Street, 61080, Trabzon, Turkey
| | - Burkhard Horstkotte
- Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| |
Collapse
|
4
|
Conde-Díaz A, Santana-Mayor Á, Herrera-Herrera AV, Socas-Rodríguez B, Rodríguez-Delgado MÁ. Assessment of endocrine disruptor pollutants and their metabolites in environmental water samples using a sustainable natural deep eutectic solvent-based analytical methodology. CHEMOSPHERE 2023; 338:139480. [PMID: 37453517 DOI: 10.1016/j.chemosphere.2023.139480] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 07/04/2023] [Accepted: 07/10/2023] [Indexed: 07/18/2023]
Abstract
In this work, an evaluation of the occurrence of fifteen phthalates, four metabolites and one adipate in different groundwater, seawater and wastewater samples has been carried out due to their relevance on human health as they act as endocrine disruptors. For this purpose, a sustainable, fast and easy-handling vortex-assisted liquid-liquid microextraction method using a natural hydrophobic deep eutectic solvent based on menthol and carvacrol as extraction agent, combined with ultra-high performance liquid chromatography-mass spectrometry technique, has been developed and applied for the first time. An optimization was performed to evaluate four important factors affecting the extraction performance, and an analytical validation was carried out in terms of matrix effect, linearity, extraction efficiency, and sensitivity. Recovery values were obtained in the range 72-119% for all analytes (except for monoethyl phthalate: 61.1-72.3%) with relative standard deviation values lower than 17%. Limits of quantification were found between 0.91 and 8.09 μg L-1. As a result of the assessment of 31 different environmental water samples, monoethyl phthalate, diethyl phthalate, dibutyl phthalate and bis (2-ethylhexyl) phthalate were detected and quantified at different concentrations in the range 2.59-21.17 μg L-1 in 6 samples, and diallyl phthalate, butyl benzyl phthalate, dipentyl phthalate, dicyclohexyl phthalate, dihexyl phthalate and bis (2-ethylhexyl) adipate were detected in 20 more, showing the exposition of the population to these hazardous substances.
Collapse
Affiliation(s)
- Adrián Conde-Díaz
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/nº. 38206, San Cristóbal de La Laguna, España
| | - Álvaro Santana-Mayor
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/nº. 38206, San Cristóbal de La Laguna, España
| | - Antonio V Herrera-Herrera
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/nº. 38206, San Cristóbal de La Laguna, España; Instituto Universitario de Bio-Orgánica Antonio González, Universidad de La Laguna (ULL), Avda. Astrofísico Fco. Sánchez, 2, 38206, San Cristóbal de La Laguna, España
| | - Bárbara Socas-Rodríguez
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/nº. 38206, San Cristóbal de La Laguna, España.
| | - Miguel Ángel Rodríguez-Delgado
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/nº. 38206, San Cristóbal de La Laguna, España.
| |
Collapse
|
5
|
Gao J, Ouyang J, Shen J, Wei Y, Wang C. Multivariate covalent organic frameworks guided carboxyl functionalized magnetic adsorbent for enrichment of fluoroquinolones in milk prior to high performance liquid chromatographic analysis. J Chromatogr A 2023; 1706:464283. [PMID: 37562103 DOI: 10.1016/j.chroma.2023.464283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 07/01/2023] [Accepted: 08/04/2023] [Indexed: 08/12/2023]
Abstract
Herein, we prepared a carboxyl functionalized magnetic covalent organic framework (Fe3O4@iCOF-COOH) by combining multivariate synthetic strategy with post-synthetic modification. It was used as an adsorbent for magnetic solid phase extraction (MSPE) of six fluoroquinolones (FQs), and showed good absorption performance at neutral pH. Carboxyl groups are found to be crucial for the adsorption of fluoroquinolones. The adsorption mechanism was primarily attributed to strong hydrogen bonding, π-π interaction as well as potential hydrophobic effect. The optimal extraction conditions are sample pH at 6.0, adsorbent dosage of 3 mg, eluent of 1.0 mL methanol solution containing 7.5% ammonia, and extraction/desorption time of 30 min. Under the optimized conditions, the Fe3O4@iCOF-COOH was used as an adsorbent for MSPE of FQs in milk, an analytical method was established by combining with high-performance liquid chromatography-ultraviolet detection (HPLC-UV). The limits of detection (LODs) and limit of quantification (LOQs) were 1.24-4.58 ng⋅mL-1 and 4.12-15.3 ng⋅mL-1, respectively. The recoveries of target FQs in spiked milk were 68.4-105%. This work provides a new way to prepare covalent organic framework based adsorbents for solid phase extraction, and can be readily extended to other type of adsorbents.
Collapse
Affiliation(s)
- Jingnan Gao
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China
| | - Jinya Ouyang
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China
| | - Jiwei Shen
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China
| | - Yinmao Wei
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China
| | - Chaozhan Wang
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China.
| |
Collapse
|
6
|
Determination of trimethoprim in milk, water and plasma using protein precipitation combined with liquid phase microextraction method. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
|
7
|
Lab-in-syringe automated protein precipitation and salting-out homogenous liquid-liquid extraction coupled online to UHPLC-MS/MS for the determination of beta-blockers in serum. Anal Chim Acta 2023; 1251:340966. [PMID: 36925276 DOI: 10.1016/j.aca.2023.340966] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 02/09/2023] [Accepted: 02/09/2023] [Indexed: 02/19/2023]
Abstract
A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions. The extract is then separated and diluted in-syringe before being submitted to online coupled UHPLC-MS/MS. A 1 mL glass syringe containing a small stir bar for solution mixing at up to 3000 rpm, was used to deal with sample volumes as small as 100 μL. A sample throughput of 7 h-1 was achieved by performing the chromatographic run and sample preparation procedure in parallel. Linear working ranges were obtained for all analytes between 5 and 100 ng mL-1, with LOD values ranging from 0.4 to 1.5 ng mL-1. Accuracy values in the range of 88.2-106% and high precision of <11% RSD suggest applicability for routine analysis that can be further improved using deuterated standards.
Collapse
|
8
|
Shishov A, Pochivalov A, Dubrovsky I, Bulatov A. Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. Talanta 2023; 255:124243. [PMID: 36630789 DOI: 10.1016/j.talanta.2022.124243] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 01/01/2023]
Abstract
In the work limitations of deep eutectic solvents in the flow-based analysis are discussed. Deep eutectic solvents based on terpenes and fatty acids with low viscosity were studied as extraction solvents for liquid-liquid microextraction into a lab-in-syringe system for the first time. As a result an automated deep eutectic solvent-based microextraction approach was proposed. The procedure involved aspiration of deep eutectic solvent (based on terpene and fatty acid) and aqueous sample solution followed by phases mixing by a magnetic stirrer inside a syringe of flow system. After phase separation the extract phase was transferred from the syringe into a vial followed by analysis by a high-performance liquid chromatography with diode-array detection. The determination of Sudan I, Sudan II and Sudan III in chili-based sauces was considered as an analytical task. The mass-transfer intensification performed by the magnetic stirring inside the syringe allowed to perform fast (2 min) and efficient (extraction recoveries 87-95%) extraction. The limits of detection, calculated from a blank test based on 3σ, were from 0.003 to 0.005 mg kg-1, RSD was <9%. The microextraction procedure did not involve the use of hazardous organic solvents, only 100 μL of natural deep eutectic solvent was required for dyes preconcentration.
Collapse
Affiliation(s)
- Andrey Shishov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia.
| | - Aleksei Pochivalov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia
| | - Ivan Dubrovsky
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia
| | - Andrey Bulatov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia
| |
Collapse
|
9
|
Zhavoronok MF, Vakh C, Bulatov A. Automated primary amine-based supramolecular solvent microextraction with monoterpenoid as coacervation agent before high-performance liquid chromatography. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2022.105085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Khafi M, Javadi A, Reza Afshar Mogaddam M. Combination of three-phase extraction with deep eutectic solvent-based dispersive liquid-liquid microextraction for the extraction of some antibiotics from egg samples prior to HPLC-DAD. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2023]
|
11
|
Andruch V, Kalyniukova A, Płotka-Wasylka J, Jatkowska N, Snigur D, Zaruba S, Płatkiewicz J, Zgoła-Grześkowiak A, Werner J. Application of deep eutectic solvents in sample preparation for analysis (update 2017–2022). Part A: Liquid phase microextraction. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
12
|
Gomez NA, Lorenzetti AS, Camiña J, Garrido M, Domini CE. In-syringe ultrasound-assisted dispersive liquid–liquid microextraction for the fluorescent determination of aluminum in water and milk samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
13
|
Fabrication of highly fluorinated porphyrin-based covalent organic frameworks decorated Fe3O4 nanospheres for magnetic solid phase extraction of fluoroquinolones. Mikrochim Acta 2022; 189:449. [DOI: 10.1007/s00604-022-05541-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 10/15/2022] [Indexed: 11/18/2022]
|
14
|
Kannouma RE, Hammad MA, Kamal AH, Mansour FR. Miniaturization of Liquid-Liquid extraction; the barriers and the enablers. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107863] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
15
|
Cerdà V, Ferreira SLC, Phansi P. Lab-in-Syringe, a Useful Technique for the Analysis and Detection of Pollutants of Emerging Concern in Environmental and Food Samples. Molecules 2022; 27:7279. [PMID: 36364111 PMCID: PMC9656442 DOI: 10.3390/molecules27217279] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 10/15/2022] [Accepted: 10/17/2022] [Indexed: 12/04/2023] Open
Abstract
Lab-in-syringe is a new approach for the integration of various analytical extraction steps inside a syringe. Fully automated dispersive liquid-liquid microextraction is carried out in-syringe using a very simple instrumental setup. Dispersion is achieved by aspiration of the organic phase and then the watery phase into the syringe as rapidly as possible. After aggregation of the solvent droplets, the organic phase is pushed towards the detector allowing a highly sensitive spectrophotometric or fluorimetric detection. This technique is very useful not only for the preconcentration of analyte, but also for the elimination of their interferences. In this work, its application is described using solvents that are lighter and denser than water. The magnetically assisted variant and its coupling to different instruments has been also described with the aim of increasing the resolution of complex samples, especially useful for the determination of emerging contaminants.
Collapse
Affiliation(s)
| | - Sergio L. C. Ferreira
- Instituto de Química, Universidade Federal da Bahia, Bahia, Salvador 40170-270, Brazil
| | - Piyawan Phansi
- Department of Chemistry, Thepsatri Rajabhat University, Lopburi 15000, Thailand
| |
Collapse
|
16
|
Fattahi N, Hashemi B, Shiri F, Shamsipur M, Babajani N. Extraction of parabens from personal care products using a pH-responsive hydrophobic deep eutectic solvent: experimental design and COSMO-RS evaluations. NEW J CHEM 2022. [DOI: 10.1039/d2nj02519a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
A pH-responsive hydrophobic deep eutectic solvent is used for the extraction of parabens from different personal care products.
Collapse
Affiliation(s)
- Nazir Fattahi
- Research Center for Environmental Determinants of Health (RCEDH), Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Beshare Hashemi
- School of Arts and Sciences, American International University, Jahra, Kuwait
| | - Fereshteh Shiri
- Department of Chemistry, Faculty of Science, University of Zabol, Zabol, Iran
| | - Mojtaba Shamsipur
- Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah, Iran
| | - Nasrin Babajani
- Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah, Iran
| |
Collapse
|