1
|
Neumark B, Elkabets O, Amirav A. Cool Classical EI - A New Standard in EI and Its Many Benefits. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:2020-2027. [PMID: 39052911 PMCID: PMC11311530 DOI: 10.1021/jasms.4c00265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/17/2024] [Accepted: 07/18/2024] [Indexed: 07/27/2024]
Abstract
GC-MS with Cold EI improves all of the central GC-MS performance aspects, but it is known mostly for its provision of enhanced molecular ions. This occasionally leads to the misconception that, like chemical ionization, Cold EI is a supplementary ion source to standard EI. However, Cold EI is a highly superior replacement ion source to standard EI. While Cold EI mass spectra are the most informative and fully compatible with mass spectral library (such as NIST) identification, in some cases, the Cold EI mass spectra with their enhanced molecular ions result in a "picture" that is not as one is used to seeing. In this paper, we describe the "Cool Classical EI" mode, which produces classical EI mass spectra like standard EI. The change of Cold EI into the Cool Classical EI mode is software-based, requires no hardware change, and can be achieved even during the analysis. Several mass spectra that were obtained in the Cool Classical EI mode are presented and compared with standard EI and Cold EI mass spectra. In this paper we further demonstrate and discuss several benefits that Cold EI brings that are retained while using Cool Classical EI, including (a) much faster speed of analysis, (b) uniform response, (c) extended range of compounds amenable for analysis, (d) improved sample identification, (e) elimination of ion source related peak tailing, (f) elimination of intraion-source degradation, and (g) better signal-to-noise ratio of the sample compounds.
Collapse
Affiliation(s)
- Benny Neumark
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Oneg Elkabets
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Aviv Amirav
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
- Aviv
Analytical Ltd., 24 Hanagar
Street, Hod Hasharon 4527713, Israel
| |
Collapse
|
2
|
Elkabets O, Neumark B, Amirav A. Sample Injection for Real-Time Analysis (SIRTA) Using GC-MS with Cold EI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:378-385. [PMID: 38234102 PMCID: PMC10853959 DOI: 10.1021/jasms.3c00412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 12/26/2023] [Accepted: 01/03/2024] [Indexed: 01/19/2024]
Abstract
There is a continual demand for advanced methods and instruments for real-time analysis (RTA). Most of the current RTA techniques based on MS involve ambient desorption ionization technology. However, flow injection of liquid extracted samples is another option without added modifications or cost to existing LC-MS instruments. In this work, we introduce a new RTA approach named sample injection for real-time analysis (SIRTA) using GC-MS with Cold EI. In SIRTA, the standard GC column is replaced with a 1 m long 0.1 mm I.D. fused silica capillary that connects the GC injector to the MS transfer-line of Cold EI. Thus, SIRTA with Cold EI imposes no need for any additional instrumentation; hence, it is characterized by zero added cost. Like in flow injection in MS of LC-MS, the sample is dissolved in ∼1 mL methanol or another solvent. Subsequently, the vial is placed in the GC-MS autosampler while using a standard syringe for injection without any GC separation. The analysis takes merely 0.2-0.7 min, ensuring rapid and consecutive analyses. Unlike standard EI, Cold EI enables SIRTA by taking advantage of its fly through open ion source to avoid overwhelming the ion source during the elution of solvents while still providing enhanced molecular ions for nearly all analytes. In this study, we demonstrated SIRTA Cold EI analysis of 12 compounds and 7 mixtures, including various prescription and illicit drugs, cannabis and petroleum samples, and other synthetic organic compounds including those with molecular weight up to 800 g/mol.
Collapse
Affiliation(s)
- Oneg Elkabets
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Benny Neumark
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Aviv Amirav
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
- Aviv
Analytical Ltd, 24 Hanagar
Street, Hod Hasharon 4527713, Israel
| |
Collapse
|
3
|
Elkabets O, Neumark B, Amirav A. Fast saliva analysis by GC-MS with Cold EI and Open Probe Fast GC-MS with Cold EI for the detection of cannabis usage. JOURNAL OF MASS SPECTROMETRY : JMS 2023; 58:e4981. [PMID: 37950648 DOI: 10.1002/jms.4981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 10/03/2023] [Accepted: 10/11/2023] [Indexed: 11/13/2023]
Abstract
Saliva is a body fluid that is much easier to collect and analyze than blood. Thus, saliva analysis for the detection of delta 9-tetrahydrocannabinol (delta 9-THC) can serve as a tool for law enforcement agents to detect cannabis consumption by drivers. Fast saliva analysis for the presence of delta 9-THC and/or cannabidiol (CBD) is described with both gas chromatography-mass spectrometry (GC-MS) with Cold electron ionization (EI) with good separation and in 10 min and/or with Open Probe Fast GC-MS with Cold EI in under 1 min full analysis cycle time. Saliva was taken directly from donors' tongues on a thin glass rod that was used "as is" for analysis. The saliva was thermally desorbed with a modified ChromatoProbe device inside the gas chromatograph (GC) injector and in an Open Probe (Agilent name QuickProbe) for its sub-1-min analysis. Cold EI is based on coupling of the GC and mass spectrometer (MS) with a supersonic molecular beam and on EI of vibrationally cold sample molecules during their flight through a contact-free ion source (thereby named Cold EI). A revised type of Open Probe Fast GC-MS on the bench is also described. Our saliva analysis was characterized by: Saliva can be collected in the field and transported to the lab for analyses "as is" without any sample preparation. Easy detection of cannabis consumption from cigarettes and/or other cannabis products. Distinction between the isomers delta 9-THC and CBD. Ultra-fast analysis in under 1 min using Open Probe Fast GC-MS with Cold EI.
Collapse
Affiliation(s)
- Oneg Elkabets
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| | - Benny Neumark
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
- Aviv Analytical Ltd, Hod Hasharon, Israel
| |
Collapse
|
4
|
Vrkoslav V, Horká P, Jindřich J, Buděšínský M, Cvačka J. Silver Ion High-Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: A Tool for Analyzing Cuticular Hydrocarbons. Molecules 2023; 28:molecules28093794. [PMID: 37175204 PMCID: PMC10179885 DOI: 10.3390/molecules28093794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/17/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023] Open
Abstract
Aliphatic hydrocarbons (HCs) are usually analyzed by gas chromatography (GC) or matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. However, analyzing long-chain HCs by GC is difficult because of their low volatility and the risk of decomposition at high temperatures. MALDI cannot distinguish between isomeric HCs. An alternative approach based on silver ion high-performance liquid chromatography (Ag-HPLC) is shown here. The separation of HC standards and cuticular HCs was accomplished using two ChromSpher Lipids columns connected in series. A gradient elution of the analytes was optimized using mobile phases prepared from hexane (or isooctane) and acetonitrile, 2-propanol, or toluene. HCs were detected by atmospheric pressure chemical ionization mass spectrometry (APCI-MS). Good separation of the analytes according to the number of double bonds, cis/trans geometry, and position of double bonds was achieved. The retention times increased with the number of double bonds, and trans isomers eluted ahead of cis isomers. The mobile phase significantly affected the mass spectra of HCs. Depending on the mobile phase composition, deprotonated molecules, molecular ions, protonated molecules, and various solvent-related adducts of HCs were observed. The optimized Ag-HPLC/APCI-MS was applied for characterizing cuticular HCs from a flesh fly, Neobellieria bullata, and cockroach, Periplaneta americana. The method made it possible to detect a significantly higher number of HCs than previously reported for GC or MALDI-MS. Unsaturated HCs were frequently detected as isomers differing by double-bond position(s). Minor HCs with trans double bonds were found beside the prevailing cis isomers. Ag-HPLC/APCI-MS has great potential to become a new tool in chemical ecology for studying cuticular HCs.
Collapse
Affiliation(s)
- Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 160 00 Prague, Czech Republic
| | - Petra Horká
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 160 00 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 128 00 Prague, Czech Republic
| | - Jindřich Jindřich
- Department of Organic Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 128 00 Prague, Czech Republic
| | - Miloš Buděšínský
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 160 00 Prague, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 160 00 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 128 00 Prague, Czech Republic
| |
Collapse
|
5
|
Neumark B, Elkabets O, Shefer G, Buch A, Stern N, Amirav A. Whole blood analysis for medical diagnostics by GC-MS with Cold EI. JOURNAL OF MASS SPECTROMETRY : JMS 2022; 57:e4873. [PMID: 35796286 PMCID: PMC9540862 DOI: 10.1002/jms.4873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 06/19/2022] [Accepted: 06/26/2022] [Indexed: 06/15/2023]
Abstract
This study covers a new method and related instrumentation for whole blood analysis for medical diagnostics. Two-μL whole blood samples were collected using "minimal invasive" diabetes lancet and placed on a thin glass rod mounted on a newly designed BloodProbe. The BloodProbe with the whole blood sample was inserted directly into a ChromatoProbe mounted on the GC inlet, and thus, no sample preparation was involved. The analysis was performed within 10 min using a GC-MS with Cold EI that is based on interfacing GC and MS with supersonic molecular beams (SMB) along with electron ionization of vibrationally cold sample compounds in the SMB (hence the name Cold EI). Our blood analysis revealed several observations: (1) Detailed mass chromatograms were generated with full range of all the nonpolar lipids in blood including fatty acids, cholesterol, cholesteryl esters, vitamin E, monoglycerides, diglycerides, and triglycerides. (2) The analysis of whole blood was found to be as informative as the conventional clinical analysis of blood serum. (3) Cholesteryl esters were more sensitive than free cholesterol alone to the effect of diet of obese people. (4) Major enhancement of several fatty acid methyl esters was found in the blood of a cancer patient with liver dysfunction. (5) Vitamin E as both α- and β-tocopherol was found with person-dependent ratio of these two compounds. (6) Elemental sulfur S8 was identified in blood. (7) Several drugs and other compounds were found and need further study of their correlation to medical issues.
Collapse
Affiliation(s)
- Benny Neumark
- School of ChemistryTel Aviv UniversityTel AvivIsrael
| | - Oneg Elkabets
- School of ChemistryTel Aviv UniversityTel AvivIsrael
| | - Gabi Shefer
- The Institute of Endocrinology, Metabolism and HypertensionTel‐Aviv Sourasky Medical CenterTel AvivIsrael
| | - Assaf Buch
- The Institute of Endocrinology, Metabolism and HypertensionTel‐Aviv Sourasky Medical CenterTel AvivIsrael
| | - Naftali Stern
- The Institute of Endocrinology, Metabolism and HypertensionTel‐Aviv Sourasky Medical CenterTel AvivIsrael
- The Sagol Center for Epigenetics of Aging and MetabolismTel‐Aviv Sourasky Medical CenterTel AvivIsrael
- Sackler Faculty of MedicineTel Aviv UniversityTel AvivIsrael
| | - Aviv Amirav
- School of ChemistryTel Aviv UniversityTel AvivIsrael
- Aviv AnalyticalHod HasharonIsrael
| |
Collapse
|
6
|
Amirav A, Fialkov AB, Gordin A, Elkabets O, Margolin Eren KJ. Cold Electron Ionization (EI) Is Not a Supplementary Ion Source to Standard EI. It is a Highly Superior Replacement Ion Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2631-2635. [PMID: 34652909 PMCID: PMC8589250 DOI: 10.1021/jasms.1c00241] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 06/13/2023]
Abstract
GC-MS usually employs a 70 eV electron ionization (EI) ion source, which provides mass spectra with detailed fragment ion information that are amenable for library search and identification with names and structures at the isomer level. However, conventional EI often suffers from low intensity or the absence of molecular ions, which reduces detection and identification capabilities in analyses. In an attempt to enhance the molecular ions, several softer ion sources are being used to supplement standard EI, including chemical ionization (CI), atmospheric pressure chemical ionization (APCI), field ionization (FI), photoionization (PI), and low electron energy EI. However, the most advantageous way to enhance molecular ions is to use cold EI, which employs 70 eV EI of cold molecules in supersonic molecular beams. Cold EI yields classical EI mass spectra with highly enhanced molecular ions, which still provides high detectability and library-searchable mass spectra. In this paper, we explain and discuss why cold EI is not a supplementary ion source to standard EI, but rather it is a highly superior replacement to standard EI. With cold EI, there is no need for standard EI or any other supplemental ion source. We describe 16 benefits and unique features of cold EI that not only yield better results for existing applications but also significantly extend the range of compounds and applications amenable for GC-MS analysis.
Collapse
Affiliation(s)
- Aviv Amirav
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
- Aviv
Analytical Ltd., 24 Hanagar
Street, Hod Hasharon 4527713, Israel
| | | | - Alexander Gordin
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Oneg Elkabets
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | | |
Collapse
|
7
|
Aharon C, Rozen S. Using fluoroform for constructing aromatic and heterocyclic trifluoromethylselenyl compounds. J Fluor Chem 2021. [DOI: 10.1016/j.jfluchem.2021.109866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Fialkov AB, Ikonen E, Laaksonen T, Amirav A. GC-MS with photoionization of cold molecules in supersonic molecular beams-Approaching the softest ionization method. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4516. [PMID: 32567120 DOI: 10.1002/jms.4516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/18/2020] [Accepted: 03/23/2020] [Indexed: 06/11/2023]
Abstract
A new type of photoionization ion source was developed for the ionization of cold molecules in supersonic molecular beams (named Cold PI). The system was based on a GC-MS with supersonic molecular beams and its fly-through EI of cold molecules ion source (Cold EI) plus quadrupole mass analyzer. A continuously operated deuterium VUV photoionization lamp was added and placed above and between the supersonic nozzle and skimmer whereas the Cold EI ion source served only as a portion of the ion transfer ion optics. The supersonic nozzle and skimmer were voltage biased and the VUV light crossed the supersonic expansion about 10 mm from the nozzle. We obtained over three orders of magnitude enhancement in the relative abundance of the molecular ion of squalane in Cold PI versus in photoionization of this compound as a thermal compound. Accordingly, we also proved that standard photoionization is not as soft ionization method as previously perceived for large compounds. We found that Cold PI is as soft as and possibly softer than field ionization; thus, it could be the softest known ionization method. The ionization yield was about 200-300 times weaker than with Cold EI yet our limit of detection was about 200 femtogram in SIM mode for cholesterol and pyrene which is reasonable. Practically, all hydrocarbons gave only molecular ions with rather uniform response whereas alcohols gave some molecular ions plus major fragment ions particularly with a loss of water (similarly to field ionization). We tested Cold PI in the GC-MS analysis of diesel fuels and analyzed the time averaged data for group type information. We also found that we can analyze the diesel fuels by fast under 20-s flow injection analysis in which the generated averaged mass spectrum of molecular ions only could serve for the characterization of fuels.
Collapse
Affiliation(s)
| | | | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
9
|
Margolin Eren KJ, Fialkov AB, Keshet U, Tsizin S, Amirav A. Doubly Charged Molecular Ions in GC-MS with Cold EI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:347-354. [PMID: 32031407 DOI: 10.1021/jasms.9b00067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
We report the finding of doubly charged molecular ions in a range of relatively large molecules including hydrocarbons upon their electron ionization as vibrationally cold molecules in supersonic molecular beams (SMB) (also named as Cold EI). Furthermore, we also report the detection by mass spectrometry of triply charged molecular ions in large PAHs such as decacyclene and ovalene upon their cooling in SMB. We found that the relative abundance of doubly charged molecular ions strongly depends on the internal vibrational cooling. While after some vibrational cooling the fragmentation pattern became cooling independent, the relative abundance of the doubly charged molecular ions was noticeably increased upon further cooling via increasing of the cooling make-up gas flow rate. In addition, the relative abundance of the doubly charged molecular ions was strongly increased with the compounds' size, and its electron energy threshold was lower than expected. These observations indicate a new mechanism that involves two separate electron ionization processes in the same compound, most likely with the same electron but at two separate atoms (places) in large molecules, to reduce Coulombic repulsion energy that can lead to fragmentation into two singly charged ions. These findings are shedding new light on electron ionization mass spectra. Accordingly, electron ionization mass spectra are the result of three separate mechanisms with relative magnitudes that depend on the compound size: (a) single electron ionization; (b) double electron ionization; and (c) single electron ionization with subsequent internal excitation by the same ionizing electron in another place.
Collapse
Affiliation(s)
| | | | - Uri Keshet
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Svetlana Tsizin
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Aviv Amirav
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
- Aviv Analytical Ltd. , 24 Hanagar Street Hod , Hasharon 4527713 , Israel
| |
Collapse
|
10
|
Fast Heroin and Cocaine Analysis by GC–MS with Cold EI: The Important Role of Flow Programming. Chromatographia 2017. [DOI: 10.1007/s10337-017-3249-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Salazar G, Agrios K, Eichler R, Szidat S. Characterization of the Axial Jet Separator with a CO2/Helium Mixture: Toward GC-AMS Hyphenation. Anal Chem 2016; 88:1647-53. [DOI: 10.1021/acs.analchem.5b03586] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- G. Salazar
- Department of Chemistry and Biochemistry & Oeschger Centre for Climate Change Research, University of Bern, 3012 Bern, Switzerland
| | - K. Agrios
- Department of Chemistry and Biochemistry & Oeschger Centre for Climate Change Research, University of Bern, 3012 Bern, Switzerland
- Paul Scherrer Institute (PSI), 5232 Villigen-PSI, Switzerland
| | - R. Eichler
- Paul Scherrer Institute (PSI), 5232 Villigen-PSI, Switzerland
| | - S. Szidat
- Department of Chemistry and Biochemistry & Oeschger Centre for Climate Change Research, University of Bern, 3012 Bern, Switzerland
| |
Collapse
|
12
|
Ullmann A, Brauner N, Vazana S, Katz Z, Goikhman R, Seemann B, Marom H, Gozin M. New biodegradable organic-soluble chelating agents for simultaneous removal of heavy metals and organic pollutants from contaminated media. JOURNAL OF HAZARDOUS MATERIALS 2013; 260:676-688. [PMID: 23832060 DOI: 10.1016/j.jhazmat.2013.06.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2012] [Revised: 06/11/2013] [Accepted: 06/12/2013] [Indexed: 06/02/2023]
Abstract
Advanced biodegradable and non-toxic organic chelators, which are soluble in organic media, were synthesized on the basis of the S,S-ethylenediamine-disuccinate (S,S-EDDS) ligand. The modifications suggested in this work include attachment of a lipophilic hydrocarbon chain ("tail") to one or both nitrogen atoms of the S,S-EDDS. The new ligands were designed and evaluated for application in the Sediments Remediation Phase Transition Extraction (SR-PTE) process. This novel process is being developed for the simultaneous removal of both heavy metals and organic pollutants from contaminated soils, sediments or sludge. The new chelators were designed to bind various target metal ions, to promote extraction of these ions into organic solvents. Several variations of attached tails were synthesized and tested. The results for one of them, N,N'-bis-dodecyl-S,S-EDDS (C24-EDDS), showed that the metal-ligand complexes are concentrated in the organic-rich phase in the Phase Transition Extraction process (more than 80%). Preliminary applications of the SR-PTE process with the C24-EDDS ligand were conducted also on actually contaminated sludge (field samples). The extraction of five toxic metals, namely, Cd, Cu, Ni, Pb and Zn was examined. In general, the extraction performance of the new ligand was not less than that of S,S-EDDS when a sufficient ligand-to-extracted ion ratio (about 4:1 was applied.
Collapse
Affiliation(s)
- Amos Ullmann
- Faculty of Engineering, School of Mechanical Engineering, Tel Aviv University, Tel Aviv 69978, Israel.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Kachala VV, Khemchyan LL, Kashin AS, Orlov NV, Grachev AA, Zalesskiy SS, Ananikov VP. Target-oriented analysis of gaseous, liquid and solid chemical systems by mass spectrometry, nuclear magnetic resonance spectroscopy and electron microscopy. RUSSIAN CHEMICAL REVIEWS 2013. [DOI: 10.1070/rc2013v082n07abeh004413] [Citation(s) in RCA: 178] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|