1
|
Shen S, Bashir M, Huysman S, Xu XE, Chang C, Yang XG, Pursch M, Chanaa S, Byrd J. Evaluation of multi-solvent size exclusion chromatography columns packed with sub-2 μm particles for the characterization of synthetic polymers. J Chromatogr A 2024; 1714:464539. [PMID: 38091713 DOI: 10.1016/j.chroma.2023.464539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/23/2023] [Accepted: 11/26/2023] [Indexed: 01/05/2024]
Abstract
With the recent development of small particle stationary-phases and dedicated instrumentation, the combination of size-exclusion chromatography (SEC) with ultra-high performance liquid chromatography (UHPLC) technology has been realized. It opened up a new polymer analysis technique called UHP-SEC. Although high resolution and fast analysis can be achieved, the multi-solvent suitability for a given column was limited to either organic or aqueous eluents. In this work, the capability of novel SEC columns (AdvanceBio SEC columns) packed with 1.9 μm particles for the characterization of synthetic polymers in organic solvents as well as the multi-solvent compatibility for organic and aqueous eluents have been demonstrated. About six times faster separation for both polystyrene (PS) and polyethylene glycol (PEG) with good peak shape and repeatability were achieved in comparison with standard SEC columns at comparable resolution. Especially for PEG, in contrast to other SEC columns, this column could provide close-to-accurate determination of molecular weights with tetrahydrofuran (THF) as mobile phase. Good reproducibility was obtained after switching several times from water to THF and vice versa with RSD% in retention times less than 0.5 %. Different samples such as polyols, isocyanates and additives can also be analyzed for molecular weight and distribution or composition determination. Volume overload, especially with injection volumes higher than 10 µL needs to be considered. This new column offers a powerful choice for oligomer and polymer analysis with both aqueous and organic mobile phase. Ultimately, hyphenating SEC columns to various detectors can enable more information regarding chemical composition, molecular weight, concentration, and structure.
Collapse
Affiliation(s)
- Sensen Shen
- Dow, Analytical Science, 201203 Shanghai, China.
| | | | - Steve Huysman
- Dow, Analytical Science, 4542 NM Terneuzen, Netherlands
| | | | | | | | | | - Sami Chanaa
- Agilent Technologies, 2850 Centerville Rd, Wilmington, DE 19808, United States
| | - Jade Byrd
- Agilent Technologies, Hewlett-Packard-Str. 8, 76337 Waldbronn, Germany
| |
Collapse
|
2
|
Pardon M, Reis R, de Witte P, Chapel S, Cabooter D. Detailed comparison of in-house developed and commercially available heart-cutting and selective comprehensive two-dimensional liquid chromatography systems. J Chromatogr A 2024; 1713:464565. [PMID: 38096685 DOI: 10.1016/j.chroma.2023.464565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 11/21/2023] [Accepted: 12/05/2023] [Indexed: 01/08/2024]
Abstract
Recently, two-dimensional liquid chromatography (2D-LC) has become a popular approach to analyze complex samples. This is partly due to the introduction of commercial 2D-LC systems. In the past, 2D-LC was carried out on in-house developed setups, typically consisting of several switching valves and sample loops as the interface between the two dimensions. Commercial systems usually offer different 2D-LC modes in combination with specialized software to operate the instrument and analyze the data. This makes them highly user-friendly, however, at an increased cost compared to in-house developed setups. This study aims to make a comparison between an in-house developed 2D-LC setup and a commercially available 2D-LC instrument. The comparison is made based on experimental differences, in addition to more general differences, including cost price, flexibility, and ease of operation. Special attention is also paid to the different strategies to deal with the mobile phase incompatibility between the highly orthogonal separation mechanisms considered in this work: hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC). For the commercial 2D-LC instrument, this is done using active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension column before transfer to the second dimension (2D) column. For the in-house developed setup, a combination of restriction capillaries and a trap column is used. Using a sample of 28 compounds with a large polarity range, peak shapes and recoveries of the 2D-chromatograms are compared for both setups. For early eluting compounds, the selective comprehensive approach, currently only possible on the commercial 2D-LC instrument, results in the best peak shapes and recoveries, however, at the cost of an increased analysis time. In general, depending on the analytical goal (single heart-cut versus full-comprehensive 2D-LC), an in-house developed system can be satisfactory for the analysis of specific target compounds/samples. For more complex problems, it can be interesting to use a more specialized commercial 2D-LC instrument. Overall, this comparison study provides advice for analytical scientists, who are considering to use 2D-LC, on the type of equipment to consider, depending on the needs of their particular applications.
Collapse
Affiliation(s)
- Marie Pardon
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium; Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Rafael Reis
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Peter de Witte
- Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Soraya Chapel
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Deirdre Cabooter
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium.
| |
Collapse
|
3
|
Kim SH, Ochar K, Hwang A, Lee YJ, Kang HJ. Variability of Glucosinolates in Pak Choy ( Brassica rapa subsp. chinensis) Germplasm. PLANTS (BASEL, SWITZERLAND) 2023; 13:9. [PMID: 38202314 PMCID: PMC10780573 DOI: 10.3390/plants13010009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/16/2023] [Accepted: 12/18/2023] [Indexed: 01/12/2024]
Abstract
Glucosinolates are sulfur-containing phytochemicals generally abundant in cruciferous vegetables such as pak choy. Glucosinolates participate in a range of biological activities essential for promoting a healthy human body. In this study, we aimed to elucidate glucosinolate variability present in pak choy germplasm that are under conservation at the Rural Development Administration Genebank, Jeonju, Republic of Korea. The Acquity Ultra-Performance Liquid Chromatography (UHPLC) analytical system was used in profiling the glucosinolate content in leaf samples of various accessions. We identified a total of 17 glucosinolates in the germplasm. Based on principal compoment analysis performed, three separate groups of the accessions were obtained. Group 1 contained the cultivar cheongsacholong which recorded high content of glucobrassicin (an indole), glucoerucin (aliphatic), gluconasturtiin (aromatic) and glucoberteroin (aliphatic). Group 2 consisted of six accessions, BRA77/72, Lu ling gaogengbai, 9041, Wuyueman, RP-75 and DH-10, predominatly high in aliphatic compounds including glucoiberin, glucocheirolin, and sinigrin. Group 3 comprised the majority of the accessions which were characterized by high content of glucoraphanin, epiprogoitrin, progoitrin, and glucotropaeolin. These results revealed the presence of variability among the pak choy germplasm based on their glucosinolate content, providing an excellent opprtunity for future breeding for improved glucosinolate content in the crop.
Collapse
Affiliation(s)
- Seong-Hoon Kim
- National Agrobiodiversity Center, National Institute of Agricultural Sciences, Rural Development Administration, Jeonju 5487, Republic of Korea; (K.O.); (A.H.); (Y.-J.L.)
| | - Kingsley Ochar
- National Agrobiodiversity Center, National Institute of Agricultural Sciences, Rural Development Administration, Jeonju 5487, Republic of Korea; (K.O.); (A.H.); (Y.-J.L.)
- Council for Scientific and Industrial Research, Plant Genetic Resources Research Institute, Bunso P.O. Box 7, Ghana
| | - Aejin Hwang
- National Agrobiodiversity Center, National Institute of Agricultural Sciences, Rural Development Administration, Jeonju 5487, Republic of Korea; (K.O.); (A.H.); (Y.-J.L.)
| | - Yoon-Jung Lee
- National Agrobiodiversity Center, National Institute of Agricultural Sciences, Rural Development Administration, Jeonju 5487, Republic of Korea; (K.O.); (A.H.); (Y.-J.L.)
| | - Hae Ju Kang
- Department of Agrofood Resources, National Institute of Agricultural Sciences, Rural Development Administration, Wanju 55365, Republic of Korea;
| |
Collapse
|
4
|
Bongaerts J, De Bundel D, Smolders I, Mangelings D, Vander Heyden Y, Van Eeckhaut A. Improving the LC-MS/MS analysis of neuromedin U-8 and neuromedin S by minimizing their adsorption behavior and optimizing UHPLC and MS parameters. J Pharm Biomed Anal 2023; 228:115306. [PMID: 36868028 DOI: 10.1016/j.jpba.2023.115306] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 02/14/2023] [Accepted: 02/15/2023] [Indexed: 02/26/2023]
Abstract
Neuromedin U (NmU) and neuromedin S (NmS) are two closely related neuropeptides belonging to the neuromedin family. NmU usually occurs either as a truncated eight amino acid long peptide (NmU-8) or as an 25 amino acid long peptide, although other molecular forms exist depending on the species considered. NmS, on the other hand, is a 36 amino acid long peptide, sharing the same amidated C-terminal heptapeptide with NmU. Nowadays, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is the preferred analytical technique for peptide quantification, because of its excellent sensitivity and selectivity. However, reaching the required quantification limits for these compounds in biological samples remains an extremely challenging task, especially because of their nonspecific binding (NSB). This study highlights the difficulties that are faced when quantifying larger neuropeptides (23-36 amino acids) compared to smaller ones (< 15 amino acids). The first part of this work aims to solve the adsorption problem for NmU-8 and NmS, by investigating the different steps involved in the sample preparation, i.e. the different solvents applied and the pipetting protocol. The addition of 0.05% plasma as an adsorption competitor was found to be primordial to avoid peptide loss due to NSB. The second part of this work focusses on further improving the sensitivity of the LC-MS/MS method for NmU-8 and NmS, by evaluating some UHPLC-parameters, including the stationary phase, the column temperature and the trapping conditions. For both peptides of interest, the best results were achieved when combining a C18 trap column with a C18 iKey separation device containing a positively charged surface. Column temperatures of 35 and 45 °C for NmU-8 and NmS respectively, resulted in the highest peak areas and S/N ratios, while applying higher column temperatures substantially decreased sensitivity. Moreover, a gradient starting at 20% organic modifier instead of 5% significantly improved the peak shape of both peptides. Finally, some compound-specific MS parameters, i.e. the capillary and the cone voltages, were evaluated. The peak areas increased with a factor 2 and 7 for NmU-8 and NmS respectively and peptide detection in the low picomolar range is now feasible.
Collapse
Affiliation(s)
- Jana Bongaerts
- Vrije Universiteit Brussel (VUB), Department of Pharmaceutical Chemistry, Drug Analysis and Drug Information, Center for Neurosciences (C4N), Laarbeeklaan 103, 1090 Brussels, Belgium; Vrije Universiteit Brussel (VUB), Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Laarbeeklaan 103, 1090 Brussels, Belgium.
| | - Dimitri De Bundel
- Vrije Universiteit Brussel (VUB), Department of Pharmaceutical Chemistry, Drug Analysis and Drug Information, Center for Neurosciences (C4N), Laarbeeklaan 103, 1090 Brussels, Belgium.
| | - Ilse Smolders
- Vrije Universiteit Brussel (VUB), Department of Pharmaceutical Chemistry, Drug Analysis and Drug Information, Center for Neurosciences (C4N), Laarbeeklaan 103, 1090 Brussels, Belgium.
| | - Debby Mangelings
- Vrije Universiteit Brussel (VUB), Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Laarbeeklaan 103, 1090 Brussels, Belgium.
| | - Yvan Vander Heyden
- Vrije Universiteit Brussel (VUB), Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Laarbeeklaan 103, 1090 Brussels, Belgium.
| | - Ann Van Eeckhaut
- Vrije Universiteit Brussel (VUB), Department of Pharmaceutical Chemistry, Drug Analysis and Drug Information, Center for Neurosciences (C4N), Laarbeeklaan 103, 1090 Brussels, Belgium.
| |
Collapse
|
5
|
Hényková E, Kaleta M, Klíčová K, Gonzalez G, Novák O, Strnad M, Kaňovský P. Quantitative Determination of Endogenous Tetrahydroisoquinolines, Potential Parkinson's Disease Biomarkers, in Mammals. ACS Chem Neurosci 2022; 13:3230-3246. [PMID: 36375023 DOI: 10.1021/acschemneuro.2c00516] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Current diagnostic options for Parkinson's disease are very limited and primarily based on characteristic clinical symptoms. Thus, there are urgent needs for reliable biomarkers that enable us to diagnose the disease in the early stages, differentiate it from other atypical Parkinsonian syndromes, monitor its progression, increase knowledge of its pathogenesis, and improve the development of potent therapies. A promising group of potential biomarkers are endogenous tetrahydroisoquinoline metabolites, which are thought to contribute to the multifactorial etiology of Parkinson's disease. The aim of this critical review is to highlight trends and limitations of available traditional and modern analytical techniques for sample pretreatment (extraction and derivatization procedures) and quantitative determination of tetrahydroisoquinoline derivatives in various types of mammalian fluids and tissues (urine, plasma, cerebrospinal fluid, brain tissue, liver tissue). Particular attention is paid to the most sensitive and specific analytical techniques, involving immunochemistry and gas or liquid chromatography coupled with mass spectrometric, fluorescence, or electrochemical detection. The review also includes a discussion of other relevant agents proposed and tested in Parkinson's disease.
Collapse
Affiliation(s)
- Eva Hényková
- Laboratory of Growth Regulators, Institute of Experimental Botany of the Czech Academy of Sciences & Palacký University, Šlechtitelů 27, 783 71 Olomouc, Czech Republic.,Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic
| | - Michal Kaleta
- Laboratory of Growth Regulators, Institute of Experimental Botany of the Czech Academy of Sciences & Palacký University, Šlechtitelů 27, 783 71 Olomouc, Czech Republic.,Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic
| | - Kateřina Klíčová
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic
| | - Gabriel Gonzalez
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic.,Department of Experimental Biology, Faculty of Science, Palacky University Olomouc, Šlechtitelů 27, 783 71 Olomouc, Czech Republic
| | - Ondřej Novák
- Laboratory of Growth Regulators, Institute of Experimental Botany of the Czech Academy of Sciences & Palacký University, Šlechtitelů 27, 783 71 Olomouc, Czech Republic
| | - Miroslav Strnad
- Laboratory of Growth Regulators, Institute of Experimental Botany of the Czech Academy of Sciences & Palacký University, Šlechtitelů 27, 783 71 Olomouc, Czech Republic.,Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic
| | - Petr Kaňovský
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic
| |
Collapse
|
6
|
Vaishnavi A. Sarangdhar, Ramanlal N. Kachave. Overview of UHPLC-MS: an Effective and Sensitive Hyphenated Technique. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822110119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
7
|
den Uijl MJ, Roeland T, Bos TS, Schoenmakers PJ, van Bommel MR, Pirok BW. Assessing the feasibility of stationary-phase-assisted modulation for two-dimensional liquid-chromatography separations. J Chromatogr A 2022; 1679:463388. [DOI: 10.1016/j.chroma.2022.463388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/18/2022] [Accepted: 07/21/2022] [Indexed: 02/06/2023]
|
8
|
Sroga GE, Stephen S, Wang B, Vashishth D. Techniques for advanced glycation end product measurements for diabetic bone disease: pitfalls and future directions. Curr Opin Endocrinol Diabetes Obes 2022; 29:333-342. [PMID: 35777968 PMCID: PMC9348815 DOI: 10.1097/med.0000000000000736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
PURPOSE OF REVIEW Multiple biochemical and biophysical approaches have been broadly used for detection and quantitation of posttranslational protein modifications associated with diabetic bone, yet these techniques present a variety of challenges. In this review, we discuss recent advancements and complementary roles of analytical (UPLC/UPLC-MS/MS and ELISA) and biophysical (Raman and FTIR) techniques used for characterization of glycation products, measured from bone matrix and serum, and provide recommendations regarding the selection of a technique for specific study of diabetic bone. RECENT FINDINGS Hyperglycemia and oxidative stress in diabetes contribute to the formation of a large subgroup of advanced glycation end products (AGEs) known as glycoxidation end products (AGOEs). AGEs/AGOEs have various adverse effects on bone health. Commonly, accumulation of AGEs/AGOEs leads to increased bone fragility. For example, recent studies show that carboxymethyllysine (CML) and pentosidine (PEN) are formed in bone at higher levels in certain diseases and metabolic conditions, in particular, in diabetes and aging. Detection and quantitation of AGEs/AGOEs in rare and/or precious samples is feasible because of a number of technological advancements of the past decade. SUMMARY Recent technological advancements have led to a significant improvement of several key analytical biochemistry and biophysics techniques used for detection and characterization of AGEs/AGOEs in bone and serum. Their principles and applications to skeletal tissue studies as well as limitations are discussed in this review.
Collapse
Affiliation(s)
- Grażyna E. Sroga
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Samuel Stephen
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Bowen Wang
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Deepak Vashishth
- Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, USA
| |
Collapse
|
9
|
A New LC-MS Method for Evaluating the Efficacy of Pesticide Residue Removal from Fruit Surfaces by Washing Agents. Processes (Basel) 2022. [DOI: 10.3390/pr10040793] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Modern agriculture uses pesticides to improve the quality and quantity of crops. However, pesticide residues can remain on agricultural products, posing very serious risks to human health and life. It is recommended to wash fruits and vegetables before consumption. To assess the removal efficacy of pesticide residue, a sensitive and reliable method based on ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and optimized for the simultaneous determination of four pesticide residues (acetamiprid, boscalid, pyraclostrobin, and pendimethalin). Isotope-labeled standards were used to validate the method in terms of recovery, linearity, matrix effects, precision, and sensitivity. The mean recovery values for both low-quality control (LQC) and high-quality control (HQC) transitions were in the range of 89–105%, and the intra-day precision was less than 13.7%. The limits of detection (LOD) and quantification (LOQ) were 0.003 mg/kg and 0.01 mg/kg, respectively. The proposed method is suitable for evaluating the quality of detergents for removing pesticide residues from fruit surfaces.
Collapse
|
10
|
A perspective on enantioselective chromatography by comparing ultra-high performance supercritical fluid chromatography and normal-phase liquid chromatography through the use of a Pirkle-type stationary phase. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
11
|
Eco-Friendly Separation of Antihyperlipidemic Combination Using UHPLC Particle-Packed and Monolithic Columns by Applying Green Analytical Chemistry Principles. SEPARATIONS 2021. [DOI: 10.3390/separations8120246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Efficient separation of pharmaceuticals and metabolites with the adequate resolution is a key factor in choosing the most suitable chromatographic method. For quality control, the analysis time is a key factor, especially in pharmacokinetic studies. High back pressure is considered as one of the most important factors in chromatography’s flow control, especially in UHPLC. The separation of the anti-hyperlipidemic mixtures was carried out using two columns: a column silica-based particle packed UHPLC and a monolithic column. The systematic suitability of the two columns was compared for the separation of Fenofibrate, its active metabolite, Fenofibric acid and Pravastatin using Atorvastatin as an internal standard. Separation on both columns was obtained using ethanol: buffer potassium dihydrogen orthophosphate pH = 3 (adjusted with orthophosphoric acid) (75:25 v/v) as mobile phase and flow rate 0.8 mL/min. The analytes’ peak detection was achieved by using a PDA detector at 287 nm, 214 nm, 236 nm, and 250 nm for Fenofibrate, Fenofibric acid, Pravastatin, and Atorvastatin, respectively. Reduction of back-pressure was achieved with the monolithic column, where the analytes could be completely separated in less than 1.5 min at a flow rate of 5 mL/min. The principles of Green Analytical Chemistry (GAC) were followed throughout the developed method using environmentally safe solvents.
Collapse
|
12
|
Pilely K, Johansen MR, Lund RR, Kofoed T, Jørgensen TK, Skriver L, Mørtz E. Monitoring process-related impurities in biologics-host cell protein analysis. Anal Bioanal Chem 2021; 414:747-758. [PMID: 34595561 PMCID: PMC8483941 DOI: 10.1007/s00216-021-03648-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 08/28/2021] [Accepted: 09/02/2021] [Indexed: 12/03/2022]
Abstract
During biologics development, manufacturers must demonstrate clearance of host cell impurities and contaminants to ensure drug purity, manufacturing process consistency, and patient safety. Host cell proteins (HCPs) are a major class of process-related impurities and require monitoring and documentation of their presence through development and manufacturing. Even in residual amounts, they are known to affect product quality and efficacy as well as patient safety. HCP analysis using enzyme-linked immunosorbent assay (HCP-ELISA) is the standard technique, due to its simple handling, short analysis time, and high sensitivity for protein impurities. Liquid chromatography mass spectrometry (LC–MS) is an orthogonal method for HCP analysis and is increasingly included in regulatory documentation. LC–MS offers advantages where HCP-ELISA has drawbacks, e.g., the ability to identify and quantify individual HCPs. This article summarizes the available knowledge about monitoring HCPs in biologics and presents the newest trends in HCP analysis with current state-of-the-art HCP measurement tools. Through case studies, we present examples of HCP control strategies that have been used in regulatory license applications, using an MS-based coverage analysis and HCP-ELISA and LC–MS for HCP quantification. This provides novel insight into the rapid evolving strategy of HCP analysis. Improvements in technologies to evaluate HCP-ELISA suitability and the implementation of orthogonal LC–MS methods for HCP analysis are important to rationally manipulate, engineer, and select suitable cell lines and downstream processing steps to limit problematic HCPs.
Collapse
|
13
|
Wang C, Tang R, Pan L, Wu W, Ma S, Wei Y, Ou J. Preparation of core-shell microporous organic polymer-coated silica microspheres for chromatographic separation and N-glycopeptides enrichment. J Sep Sci 2021; 45:1458-1468. [PMID: 34559936 DOI: 10.1002/jssc.202100466] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 09/14/2021] [Accepted: 09/17/2021] [Indexed: 11/10/2022]
Abstract
Through a "one-pot" strategy, a layer of microporous organic polymer was coated onto the surface of monodisperse amino-functionalized silica microsphere via amino-aldehyde condensation reaction with core-shell structure. The change in chemical structure of material before and after modification was determined by Fourier-transform infrared spectroscopy and X-ray photoelectron spectroscopy. Due to existence of a large number of amino and aldehyde groups in microporous organic polymer shell, the water contact angle decreased from 56.8° (silica microspheres) to 34.7° (microporous organic polymer-coated silica microspheres). Based on these properties, microporous organic polymer-coated silica microspheres were employed as the stationary phase for capillary liquid chromatography and successfully offered baseline separation of polar small molecules. Additionally, the material could also be served as the sorbent of hydrophilic interaction chromatography to enrich glycopeptides from human serum digest. A total of 470 unique N-glycopeptides and 342 N-glycosylation sites mapped to 112 N-glycosylated proteins were unambiguously identified from 2 μL of human serum, exhibiting a promising application prospect of microporous organic polymer-coated silica microspheres in the pretreatment of proteomics samples.
Collapse
Affiliation(s)
- Chenyang Wang
- Key Laboratory of Synthetic and Natural Function Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an, P. R. China.,Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China
| | - Ruizhi Tang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China
| | - Lei Pan
- Key Laboratory of Synthetic and Natural Function Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an, P. R. China.,Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China
| | - Wenrui Wu
- Key Laboratory of Synthetic and Natural Function Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an, P. R. China.,Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China
| | - Shujuan Ma
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China
| | - Yinmao Wei
- Key Laboratory of Synthetic and Natural Function Molecule Chemistry of Ministry of Education, College of Chemistry and Materials Science, Northwest University, Xi'an, P. R. China
| | - Junjie Ou
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, P. R. China.,University of Chinese Academy of Sciences, Beijing, P. R. China
| |
Collapse
|
14
|
Mazzoccanti G, Manetto S, Bassan M, Macis M, Iazzetti A, Cabri W, Ricci A, Gasparrini F. Expanding the Use of Dynamic Electrostatic Repulsion Reversed-Phase Chromatography: An Effective Elution Mode for Peptides Control and Analysis. Molecules 2021; 26:4348. [PMID: 34299626 PMCID: PMC8303375 DOI: 10.3390/molecules26144348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/16/2021] [Accepted: 07/16/2021] [Indexed: 11/17/2022] Open
Abstract
Bioactive peptides are increasingly used in clinical practice. Reversed-phase chromatography using formic or trifluoroacetic acid in the mobile phase is the most widely used technique for their analytical control. However, sometimes it does not prove sufficient to solve challenging chromatographic problems. In the search for alternative elution modes, the dynamic electrostatic repulsion reversed-phase was evaluated to separate eight probe peptides characterised by different molecular weights and isoelectric points. This technique, which involves TBAHSO4 in the mobile phase, provided the lowest asymmetry and peak width at half height values and the highest in peak capacity (about 200 for a gradient of 30 min) and resolution concerning the classic reversed-phase. All analyses were performed using cutting-edge columns developed for peptide separation, and the comparison of the chromatograms obtained shows how the dynamic electrostatic repulsion reversed-phase is an attractive alternative to the classic reversed-phase.
Collapse
Affiliation(s)
- Giulia Mazzoccanti
- Department of Drug Chemistry and Technology, “Sapienza” University of Rome, 00185 Rome, Italy; (S.M.); (F.G.)
| | - Simone Manetto
- Department of Drug Chemistry and Technology, “Sapienza” University of Rome, 00185 Rome, Italy; (S.M.); (F.G.)
| | - Michele Bassan
- Fresenius Kabi iPSUM, Piazza Maestri del Lavoro 7, 20063 Cernusco sul Naviglio, Italy; (M.B.); (M.M.)
| | - Marco Macis
- Fresenius Kabi iPSUM, Piazza Maestri del Lavoro 7, 20063 Cernusco sul Naviglio, Italy; (M.B.); (M.M.)
| | - Antonia Iazzetti
- Department of Basic Biotechnological Sciences, Intensivological and Perioperative Clinics, Catholic University of Sacred Heart, 00168 Rome, Italy;
| | - Walter Cabri
- Department of Chemistry, Alma Mater Studiorum-University of Bologna, Via Selmi 2, 40126 Bologna, Italy;
| | - Antonio Ricci
- Fresenius Kabi iPSUM, Piazza Maestri del Lavoro 7, 20063 Cernusco sul Naviglio, Italy; (M.B.); (M.M.)
| | - Francesco Gasparrini
- Department of Drug Chemistry and Technology, “Sapienza” University of Rome, 00185 Rome, Italy; (S.M.); (F.G.)
| |
Collapse
|
15
|
Advancements in the preparation and application of monolithic silica columns for efficient separation in liquid chromatography. Talanta 2021; 224:121777. [PMID: 33379011 DOI: 10.1016/j.talanta.2020.121777] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/11/2020] [Accepted: 10/12/2020] [Indexed: 01/23/2023]
Abstract
Fast and efficient separation remains a big challenge in high performance liquid chromatography (HPLC). The need for higher efficiency and resolution in separation is constantly in demand. To achieve that, columns developed are rapidly moving towards having smaller particle sizes and internal diameters (i.d.). However, these parameters will lead to high back-pressure in the system and will burden the pumps of the HPLC instrument. To address this limitation, monolithic columns, especially silica-based monolithic columns have been introduced. These columns are being widely investigated for fast and efficient separation of a wide range of molecules. The present article describes the current methods developed to enhance the column efficiency of particle packed columns and how silica monolithic columns can act as an alternative in overcoming the low permeability of particle packed columns. The fundamental processes behind the fabrication of the monolith including the starting materials and the silica sol-gel process will be discussed. Different monolith derivatization and end-capping processes will be further elaborated and followed by highlights of the performance such monolithic columns in key applications in different fields with various types of matrices.
Collapse
|
16
|
Ali F, Cheong WJ, Rafique A, AlOthman ZA, Sadia M, Muhammad M. Particle packed mixed-mode chromatographic stationary phase for the separation of peptide in liquid chromatography. J Sep Sci 2021; 44:1430-1439. [PMID: 33492780 DOI: 10.1002/jssc.202100001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 01/20/2021] [Accepted: 01/21/2021] [Indexed: 11/09/2022]
Abstract
A particle-based stationary phase has been prepared for the separation of five synthetic peptides and a mixture containing tryptic digest of cytochrome C in liquid chromatography. Particles originating from silica monolith were differentially sedimented to obtain 1-2 μm particles. A stationary phase was achieved by the coating of poly(styrene-methacrylic acid-N-phenylacrylamide) copolymer onto the particles via reversible addition-fragmentation chain transfer polymerization reaction. Stainless steel column (30 cm long and 1 mm internal diameter) was packed with stationary phase. Very high separation efficiency (ca. 351 000 plates/m) was achieved for five commercial peptides with a percent relative standard deviation of less than 1%. Protocol for the synthesis and modification of silica monolith particles has been well optimized with a good reproducibility both in particle and pore size. The column resolved about 21 peptide components from a mixture containing tryptic digest of cytochrome C, under the elution conditions of acetonitrile/15 mM ammonium format (65/35 v/v%) with a flow rate of 28 μL/min.
Collapse
Affiliation(s)
- Faiz Ali
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan.,Department of Chemistry, Inha University, Incheon, South Korea
| | - Won Jo Cheong
- Department of Chemistry, Inha University, Incheon, South Korea
| | - Aamra Rafique
- Department of Chemistry, Faculty of Basic and Applied Sciences, University of The Poonch, Rawalakot, Pakistan
| | - Zeid A AlOthman
- Advanced Materials Research Chair, Chemistry Department, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Maria Sadia
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
| | - Mian Muhammad
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
| |
Collapse
|
17
|
Bartlett MG, Omuro S. Evaluation of alkylamines and stationary phases to improve LC-MS of oligonucleotides. Biomed Chromatogr 2020; 35:e5045. [PMID: 33283300 DOI: 10.1002/bmc.5045] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 11/02/2020] [Accepted: 12/01/2020] [Indexed: 12/20/2022]
Abstract
This study evaluated four bridged-ethylene hybrid (BEH) columns containing C18 (130 Å), peptide C18 (300 Å), phenyl, or a mixed-mode charged surface hybrid (CSH C18 ) using a wide range of antisense oligonucleotide therapeutics. The BEH C18 , peptide, and phenyl columns were all capable of providing significant retention of oligonucleotide samples across multiple ion-pairing systems using alkylamines and 1,1,1,3,3,3,-hexafluoroisopropanol (HFIP). The retention of the oligonucleotides varied depending on the choice of alkylamine, with the order of retention being dimethylcyclohexylamine > diisopropylethylamine > triethylamine. The selectivity of these columns for several closely eluting impurities was similar. Although overall the C18 , peptide, and phenyl columns were all found to be capable of analyzing oligonucleotide therapeutics, the phenyl column was found to be the most retentive and the C18 column provided the best peak shape. The CSH C18 column was found to be degraded by the alkylamine-HFIP mobile phase despite the mobile phase being within the pH stability range of the column.
Collapse
Affiliation(s)
- Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| | - Shogo Omuro
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| |
Collapse
|
18
|
Column-in-valve designs to minimize extra-column volumes. J Chromatogr A 2020; 1637:461779. [PMID: 33385742 DOI: 10.1016/j.chroma.2020.461779] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/23/2020] [Accepted: 11/26/2020] [Indexed: 11/23/2022]
Abstract
We report on the design and performance of in-house built column cartridges that can be directly screwed into the ports of a commercial rotor-stator valve to minimize extra-column band broadening and pressure-drop losses when pursuing ultra-fast separations such as those needed in 2D and 3D-LC separations. Two basic designs were evaluated and were compared with the results obtained with a commercial screw-in column cartridge. The system produces an extra-column band broadening as low as 0.05 to 0.1 μL2 for the employed UV-detector set-up. Despite these very low values, the obtained separation efficiency of the in-house fabricated cartridge columns was very low, corresponding to a reduced minimal plate height around h=7 at the very best, which, for the 1.7 μm particle and 26.4 mm long columns corresponds to a number of theoretical plates of N=2200 under isocratic conditions. A similar poor performance was obtained with a commercial column cartridge with similar dimensions using the same set-up. One possible explanation of the observed performance could be found in the inner diameter of the column cartridges (i.d. =0.75 mm and 1 mm) which, for the employed sub 2-μm particles, falls into a region of column diameters that, according to literature models, is most likely to suffer from inherent packing problems.
Collapse
|
19
|
Selection of calibration compounds for selectivity evaluation of siloxane-bonded silica columns for reversed-phase liquid chromatography by the solvation parameter model. J Chromatogr A 2020; 1633:461652. [DOI: 10.1016/j.chroma.2020.461652] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 10/07/2020] [Accepted: 10/26/2020] [Indexed: 02/02/2023]
|
20
|
Fedorova EN, Varlamova DO, Kivero AD, Guk KD, Ptitsyn LR. Ultra-performance liquid chromatography (UPLC) for the determination of organic acids – The intermediates of branched-chain amino acid biosynthesis in Escherichia coli strains. J LIQ CHROMATOGR R T 2020. [DOI: 10.1080/10826076.2020.1832894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
21
|
Wicht K, Baert M, Kajtazi A, Schipperges S, von Doehren N, Desmet G, de Villiers A, Lynen F. Pharmaceutical impurity analysis by comprehensive two-dimensional temperature responsive × reversed phase liquid chromatography. J Chromatogr A 2020; 1630:461561. [PMID: 32992220 DOI: 10.1016/j.chroma.2020.461561] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 09/10/2020] [Accepted: 09/17/2020] [Indexed: 12/11/2022]
Abstract
In this study, the possibilities of temperature responsive × reversed phase liquid chromatography (TRLC × RPLC) are assessed in terms of pharmaceutical impurity analysis. Due to the increased peak capacity per unit time they offer, two-dimensional LC approaches are gaining relevance for the analysis of complex drug formulations. Because the latter depicts a larger predisposition for the occurrence of an increased number of impurities, current 1D-HPLC approaches often prove insufficient. Since many LC × LC methods are limited by modulation, solvent compatibility, orthogonality, and sensitivity issues, the combination of TRLC × RPLC is explored in this work for pharmaceutical impurity analysis. As this combination of a purely aqueous separation with RPLC allows for systematic and optimization-free refocusing in the second dimension, it opens possibilities for generic LC × LC requiring minimal to no method development, in this way overcoming a major perceived contemporary hurdle of LC × LC. The approach is demonstrated with a representative mixture of 17 solutes comprising 11 corticosteroids and 6 progestogens. Orthogonality and peak capacities were assessed on three RP core-shell column selectivities (Poroshell EC-C18, phenyl-hexyl and PFP). Although the TRLC × EC-C18 combination offered somewhat better orthogonality, the combination with the PFP column proved the best for the separation at hand. Depending on the composition of the mixture, the use of full, shifted, or segmented gradients allowed facile optimization of the separation. The developed platform allowed detection of the impurities at the 0.05% level compared to a selected main compound, while also opening up possibilities for analysis of formulations comprising two active ingredients.
Collapse
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Ardiana Kajtazi
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard St 8, D-76337 Waldbronn, Germany
| | | | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussel, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602 Matieland, South Africa
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium.
| |
Collapse
|
22
|
Mazzoccanti G, Manetto S, Bassan M, Foschini A, Orlandin A, Ricci A, Cabri W, Ismail OH, Catani M, Cavazzini A, Gasparrini F. Boosting basic-peptide separation through dynamic electrostatic-repulsion reversed-phase (d-ERRP) liquid chromatography. RSC Adv 2020; 10:12604-12610. [PMID: 35497586 PMCID: PMC9051050 DOI: 10.1039/d0ra01296c] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 03/23/2020] [Indexed: 11/21/2022] Open
Abstract
The application of a novel chromatographic approach to therapeutic peptides bearing basic amino acids in their structure allowed unprecedented resolution of their related impurities (including epimeric isobaric ones), resulting in a superior analytical tool for the evaluation of the quality of these drugs in the market. A simple and effective chromatographic method has allowed unprecedented resolution of basic peptide and their related impurities, including the very challenging epimeric isobaric ones.![]()
Collapse
Affiliation(s)
- Giulia Mazzoccanti
- Department of Pharmaceutical Chemistry and Technology, "Sapienza" University of Rome Rome Italy
| | - Simone Manetto
- Department of Pharmaceutical Chemistry and Technology, "Sapienza" University of Rome Rome Italy
| | - Michele Bassan
- Fresenius Kabi iPSUM Piazza Maestri del Lavoro 7, Cernusco sul Naviglio 20063 MI Italy
| | - Alberto Foschini
- Fresenius Kabi iPSUM Piazza Maestri del Lavoro 7, Cernusco sul Naviglio 20063 MI Italy
| | - Andrea Orlandin
- Fresenius Kabi iPSUM Piazza Maestri del Lavoro 7, Cernusco sul Naviglio 20063 MI Italy
| | - Antonio Ricci
- Fresenius Kabi iPSUM Piazza Maestri del Lavoro 7, Cernusco sul Naviglio 20063 MI Italy
| | - Walter Cabri
- Fresenius Kabi iPSUM Piazza Maestri del Lavoro 7, Cernusco sul Naviglio 20063 MI Italy .,Department of Chemistry, Alma Mater Studiorum-University of Bologna Via Selmi2 40126 Bologna Italy
| | - Omar H Ismail
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara Ferrara Italy
| | - Martina Catani
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara Ferrara Italy
| | - Alberto Cavazzini
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara Ferrara Italy
| | - Francesco Gasparrini
- Department of Pharmaceutical Chemistry and Technology, "Sapienza" University of Rome Rome Italy
| |
Collapse
|
23
|
Hyung SW, Kim B. Bias reduction in the quantitative analysis of a target analyte present in a limited quantity in human plasma using dual-mode heart-cutting two-dimensional liquid chromatography coupled with isotope dilution mass spectrometry. Biomed Chromatogr 2020; 34:e4831. [PMID: 32181511 DOI: 10.1002/bmc.4831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 02/28/2020] [Accepted: 03/13/2020] [Indexed: 11/07/2022]
Abstract
Dual-mode heart-cutting two-dimensional liquid chromatography (DMHC 2D-LC) was applied to isotope dilution mass spectrometry (IDMS) to reduce the bias in the quantitative analysis of a target analyte present in a limited quantity in human plasma. Based on a Waters I-Class LC system, the DMHC 2D-LC system was operated in one- and two-dimensional modes to facilitate the determination of heart-cutting time and the efficient trapping of the target LC eluate. Experiments to determine the feasibility of coupling with IDMS were performed with triple quadrupole mass spectrometry using folic acid standards and/or 13 C5 -folic acid. To validate the performance of the DMHC 2D-LC/IDMS system on a complex sample, human plasma was analyzed for folic acid and the result was compared with that obtained using conventional single-column LC. The total run time of the DMHC 2D-LC system was 20 min, the same as that of the single-column LC system. The peak profile of the spiked 13 C5 -folic acid obtained with single-column LC/MS was affected by matrix effects, but resolved with DMHC 2D-LC/MS, thus improving the accuracy of the analysis. The DMHC 2D-LC/IDMS system showed reliable performance in analyzing the target analyte in human plasma, eliminating matrix effects and saving analysis time.
Collapse
Affiliation(s)
- Seok-Won Hyung
- Division of Chemical and Medical Metrology, Korea Research Institute of Standards and Science, Daejeon, South Korea
| | - Byungjoo Kim
- Division of Chemical and Medical Metrology, Korea Research Institute of Standards and Science, Daejeon, South Korea
| |
Collapse
|
24
|
Trindade EP, Regis FT, Araújo da Silva G, Nunes Aguillar B, de Paiva Amorim MV, Ramos Ferreira GL, Soares Aragão CF, da Silva Solon LG. Laboratory-Scale Preparation and Characterization of Dried Extract of Muirapuama ( Ptychopetalumolacoides Benth) by Green Analytical Techniques. Molecules 2020; 25:molecules25051095. [PMID: 32121455 PMCID: PMC7179191 DOI: 10.3390/molecules25051095] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/24/2020] [Accepted: 02/25/2020] [Indexed: 12/25/2022] Open
Abstract
This work reports on the preparation of a drying process from the ethanolic extract of Muirapuama and its characterization through green analytical techniques. The spray-drying processes were performed by using ethanolic extract in a ratio of 1:1 extract/excipient and 32 factorial design. The properties of dried powder were investigated in terms of total flavonoid content, moisture content, powder yield, and particle size distribution. An analytical eco-scale was applied to assess the greenness of the developed protocol. Ultra-high performance liquid chromatography (UHPLC)with reduced solvent consumption in the analysis was compared to the conventional HPLC method. A Fourier transform near-infrared (FT-NIR) spectroscopic method was applied based on the principal component scores for the prediction of extract/excipient mixtures and partial least squares regression model for quantitative analysis. NIR spectroscopy is an economic, powerful, and fast methodology for the detection of excipient in muirapuama dried extracts, generating no residue in the analysis. Scanning electron microscopy (SEM) images showed samples with a higher concentration of excipient, presenting better morphological characteristics and a lower moisture absorption rate. An eco-scale score value of 85 was achieved for UHPLC and 100 was achieved for NIR (excellent green analysis). Above all, these methods are rapid and green for the routine analysis of herbal medicines based on dried extracts.
Collapse
Affiliation(s)
- Ester Paulitsch Trindade
- Post-Graduate Program in Pharmaceutical Sciences—PPGCF, Federal University of Amapá—UNIFAP, Rod. Juscelino Kubitschek, Km2, Macapá-AP 68903-419, Brazil; (F.T.R.); (G.A.d.S.)
- Correspondence: (E.P.T.); (L.G.d.S.S.); Tel.: +55-96-98140-1243 (E.P.T.)
| | - Franklin Teixeira Regis
- Post-Graduate Program in Pharmaceutical Sciences—PPGCF, Federal University of Amapá—UNIFAP, Rod. Juscelino Kubitschek, Km2, Macapá-AP 68903-419, Brazil; (F.T.R.); (G.A.d.S.)
| | - Gabriel Araújo da Silva
- Post-Graduate Program in Pharmaceutical Sciences—PPGCF, Federal University of Amapá—UNIFAP, Rod. Juscelino Kubitschek, Km2, Macapá-AP 68903-419, Brazil; (F.T.R.); (G.A.d.S.)
- Organic Chemistry and Biochemistry Laboratory, State University of Amapá, UEAP, Avenida Presidente Vargas, 650, Macapá-AP 68900-070, Brazil
| | - Breno Nunes Aguillar
- Drug Quality Control and Bromatology Laboratory—LCqB, Federal University of Amapá—UNIFAP, Rod. JuscelinoKubitschek, Km2, Macapá-AP 68903-419, Brazil;
| | - Marcelo Vítor de Paiva Amorim
- Research Group on Food and Medicines—NUPLAM, Federal University of Rio Grande do Norte—UFRN, Natal-RN 59072-970, Brazil;
| | - George Leandro Ramos Ferreira
- Drug Quality Control Laboratory, Pharmaceutical Sciences Department, Federal University of Rio Grande do Norte-UFRN, Av. General Cordeiro de Farias s/n, Natal-RN 59012-570, Brazil; (G.L.R.F.); (C.F.S.A.)
| | - Cícero Flávio Soares Aragão
- Drug Quality Control Laboratory, Pharmaceutical Sciences Department, Federal University of Rio Grande do Norte-UFRN, Av. General Cordeiro de Farias s/n, Natal-RN 59012-570, Brazil; (G.L.R.F.); (C.F.S.A.)
| | - Lílian Grace da Silva Solon
- Post-Graduate Program in Pharmaceutical Sciences—PPGCF, Federal University of Amapá—UNIFAP, Rod. Juscelino Kubitschek, Km2, Macapá-AP 68903-419, Brazil; (F.T.R.); (G.A.d.S.)
- Drug Quality Control and Bromatology Laboratory—LCqB, Federal University of Amapá—UNIFAP, Rod. JuscelinoKubitschek, Km2, Macapá-AP 68903-419, Brazil;
- Correspondence: (E.P.T.); (L.G.d.S.S.); Tel.: +55-96-98140-1243 (E.P.T.)
| |
Collapse
|
25
|
Ultra-high performance liquid chromatography-MS/MS (UHPLC-MS/MS) in practice: analysis of drugs and pharmaceutical formulations. FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES 2019. [DOI: 10.1186/s43094-019-0007-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Abstract
Background
UHPLC-MS/MS is connected in various research facilities for the qualitative and quantitative investigation of a pharmaceutical substance, pharmaceutical items, and biological specimen.
Main body
The commence review article is an endeavor to offer pervasive awareness around assorted aspects and details about the UHPLC-MS/MS and related techniques with the aim on practice to an estimation of medicinal active agents in the last 10 years. The article also focused on isolation, separation, and characterization of present impurity in drug and biological samples.
Conclusion
Review article compiles a general overview of medicinally important drugs and their analysis with UHPLC-MS/MS. It gives fundamental thought regarding applications of UHPLC-MS/MS for the study on safety limit. The summary of developed UHPLC-MS/MS methods gives a contribution to the future trend and limitations in this area of research.
Collapse
|
26
|
Kaplitz AS, Kresge GA, Selover B, Horvat L, Franklin EG, Godinho JM, Grinias KM, Foster SW, Davis JJ, Grinias JP. High-Throughput and Ultrafast Liquid Chromatography. Anal Chem 2019; 92:67-84. [DOI: 10.1021/acs.analchem.9b04713] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Alexander S. Kaplitz
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Glenn A. Kresge
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Benjamin Selover
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Leah Horvat
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | | | - Justin M. Godinho
- Advanced Materials Technology, Inc., Wilmington, Delaware 19810, United States
| | - Kaitlin M. Grinias
- Analytical Platforms & Platform Modernization, GlaxoSmithKline, Upper Providence, Collegeville, Pennsylvania 19426, United States
| | - Samuel W. Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Joshua J. Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - James P. Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| |
Collapse
|
27
|
Desmet G, Broeckhoven K. Extra-column band broadening effects in contemporary liquid chromatography: Causes and solutions. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115619] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
28
|
Ali F, Malik AR, Cheong WJ, Rehman NUR. Demonstration of high separation efficiency for polystyrene-modified sub-1 µm particles originating from silica monolith under isocratic elution mode in liquid chromatography. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1665539] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Faiz Ali
- Department of Chemistry, University of Malakand, Chakdara, Pakistan
- Department of Chemistry, Faculty of Basic and Applied Sciences, University of the Poonch, Rawalakot, Pakistan
- Department of Chemistry, Inha University, Incheon, South Korea
| | - Aamra Rafique Malik
- Department of Chemistry, Faculty of Basic and Applied Sciences, University of the Poonch, Rawalakot, Pakistan
| | - Won Jo Cheong
- Department of Chemistry, Inha University, Incheon, South Korea
| | | |
Collapse
|
29
|
|
30
|
Electrochemical Characterization of Mancozeb Degradation for Wastewater Treatment Using a Sensor Based on Poly (3,4-ethylenedioxythiophene) (PEDOT) Modified with Carbon Nanotubes and Gold Nanoparticles. Polymers (Basel) 2019; 11:polym11091449. [PMID: 31487849 PMCID: PMC6780876 DOI: 10.3390/polym11091449] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/18/2019] [Accepted: 08/30/2019] [Indexed: 01/03/2023] Open
Abstract
Mancozeb is a worldwide fungicide used on a large scale in agriculture. The active component and its main metabolite, ethylene thiourea, has been related to health issues. Robust, fast, and reliable methodologies to quantify its presence in water are of great importance for environmental and health reasons. The electrochemical evaluation of mancozeb using a low-cost electrochemical electrode modified with poly (3,4-ethylene dioxythiophene), multi-walled carbon nanotubes, and gold nanoparticles is a novel strategy to provide an in-situ response for water pollution from agriculture. Additionally, the thermal-, electrochemical-, and photo-degradation of mancozeb and the production of ethylene thiourea under controlled conditions were evaluated in this research. The mancozeb solutions were characterized by electrochemical oxidation and ultraviolet-visible spectrophotometry, and the ethylene thiourea concentration was measured using ultra-high-performance liquid chromatography high-resolution mass spectrometry. The degradation study of mancozeb may provide routes for treatment in wastewater treatment plants. Therefore, a low-cost electrochemical electrode was fabricated to detect mancozeb in water with a robust electrochemical response in the linear range as well as a quick response at a reduced volume. Hence, our novel modified electrode provides a potential technique to be used in environmental monitoring for pesticide detection.
Collapse
|
31
|
Öncü Kaya EM, Korkmaz OT, Yeniceli Uğur D, Şener E, Tunçel AN, Tunçel M. Determination of Ochratoxin-A in the brain microdialysates and plasma of awake, freely moving rats using ultra high performance liquid chromatography fluorescence detection method. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1125:121700. [DOI: 10.1016/j.jchromb.2019.06.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 06/21/2019] [Accepted: 06/22/2019] [Indexed: 12/18/2022]
|
32
|
Issa Isaac N, Philippe D, Nicholas A, Raoult D, Eric C. Metaproteomics of the human gut microbiota: Challenges and contributions to other OMICS. CLINICAL MASS SPECTROMETRY 2019; 14 Pt A:18-30. [DOI: 10.1016/j.clinms.2019.06.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 06/02/2019] [Accepted: 06/03/2019] [Indexed: 12/22/2022]
|
33
|
Baca M, Desmet G, Ottevaere H, De Malsche W. Achieving a Peak Capacity of 1800 Using an 8 m Long Pillar Array Column. Anal Chem 2019; 91:10932-10936. [DOI: 10.1021/acs.analchem.9b02236] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Martyna Baca
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussels B-1050, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussels B-1050, Belgium
| | - Heidi Ottevaere
- Department of Applied Physics and Photonics, Vrije Universiteit Brussel, Brussels B-1050, Belgium
| | - Wim De Malsche
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussels B-1050, Belgium
| |
Collapse
|
34
|
Ali A, Sun G, Kim JS, Cheong WJ. Polystyrene bound silica monolith particles of reduced size as stationary phase of excellent separation efficiency in high performance liquid chromatograhy. J Chromatogr A 2019; 1594:72-81. [DOI: 10.1016/j.chroma.2019.02.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 02/03/2019] [Accepted: 02/06/2019] [Indexed: 01/01/2023]
|
35
|
Fatima Z, Jin X, Zou Y, Kaw HY, Quinto M, Li D. Recent trends in analytical methods for water-soluble vitamins. J Chromatogr A 2019; 1606:360245. [PMID: 31122728 DOI: 10.1016/j.chroma.2019.05.025] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 04/30/2019] [Accepted: 05/13/2019] [Indexed: 12/28/2022]
Abstract
In this review, recent advances in the analysis of water-soluble vitamins (WSVs) have been reported considering the advantages and disadvantages of various extraction, separation and detection techniques, commonly used for their quantification. Acid hydrolysis, enzyme treatment, SPE based methods and some other extraction methods have been discussed. Particular attention has been devoted to the analytical techniques based on liquid chromatography and electrophoresis. Furthermore, suitability and selectivity of hydrophilic interaction liquid chromatography (HILIC) for WSVs has been discussed in detail. Problems related to these techniques and their possible solutions have also been considered. Special focus has been given to the applications of liquid chromatography (since 2014-2019) for the simultaneous analysis of WSVs and their homologous in complex food samples.
Collapse
Affiliation(s)
- Zakia Fatima
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China
| | - Xiangzi Jin
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China
| | - Yilin Zou
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China
| | - Han Yeong Kaw
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China
| | - Maurizio Quinto
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China; SAFE - Department of Science of Agriculture, Food and Environment, University of Foggia, via Napoli 25, I-71100 Foggia, Italy
| | - Donghao Li
- Department of Chemistry, MOE Key Laboratory of Natural Resources of the Changbai Mountain and Functional Molecules, Yanbian University, Park Road 977, Yanji 133002, Jilin Province, PR China.
| |
Collapse
|
36
|
Abstract
The high performance of chemically-modified silica gel packing materials is based on the utilization of pure silica gels. Earlier silica gels used to be made from inorganic silica; however, nowadays, silica gels are made from organic silanes. The surface smoothness and lack of trace metals of new silica gels permits easy surface modifications (chemical reactions) and improves the reproducibility and stability. Sharpening peak symmetry is based on developing better surface modification methods (silylation). Typical examples can be found in the chromatography of amitriptyline for silanol testing and that of quinizarin for trace metal testing. These test compounds were selected and demonstrated sensitive results in the measurement of trace amounts of either silanol or trace metals. Here, we demonstrate the three-dimensional model chemical structures of bonded-phase silica gels with surface electron density for easy understanding of the molecular interaction sites with analytes. Furthermore, a quantitative explanation of hydrophilic and hydrophobic liquid chromatographies was provided. The synthesis methods of superficially porous silica gels and their modified products were introduced.
Collapse
|
37
|
Dores-Sousa JL, De Vos J, Eeltink S. Resolving power in liquid chromatography: A trade-off between efficiency and analysis time. J Sep Sci 2018; 42:38-50. [DOI: 10.1002/jssc.201800891] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/13/2018] [Accepted: 09/13/2018] [Indexed: 01/28/2023]
Affiliation(s)
- José Luís Dores-Sousa
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Jelle De Vos
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Sebastiaan Eeltink
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| |
Collapse
|
38
|
Liang Y, Zhou T. Recent advances of online coupling of sample preparation techniques with ultra high performance liquid chromatography and supercritical fluid chromatography. J Sep Sci 2018; 42:226-242. [PMID: 30136406 DOI: 10.1002/jssc.201800721] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/02/2018] [Accepted: 08/04/2018] [Indexed: 12/12/2022]
Abstract
Ultra high performance liquid chromatography and supercritical fluid chromatography techniques are favored because of their high efficiency and fast analysis speed. Although many sample preparation techniques have been coupled with common liquid chromatography online, the online coupling of sample preparation with the two popular chromatography techniques have gained increasing attention owing to the increasing requirements of efficiency and sensitivity. In this review, we have discussed and summarized the recent advances of the online coupling of sample preparation with ultra high performance liquid chromatography and supercritical fluid chromatography techniques. The main sample preparation techniques that have been coupled with ultra high performance liquid chromatography online are solid-phase extraction and in-tube solid-phase microextraction, while solid-phase extraction and supercritical fluid extraction are the main techniques that have been coupled with supercritical fluid chromatography online. Especially, the strategies for online coupling of sample preparation with chromatography techniques were summarized. Typical applications and growing trends of the online coupling techniques were also discussed in detail. With the increasing demands of improving the efficiency, throughput, and analytical capability toward complex samples of the analysis methods, online coupling of sample preparation with chromatography techniques will acquire further development.
Collapse
Affiliation(s)
- Yanshan Liang
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, P. R. China
| | - Ting Zhou
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, P. R. China
| |
Collapse
|
39
|
Poole CF. Chromatographic test methods for characterizing alkylsiloxane-bonded silica columns for reversed-phase liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1092:207-219. [DOI: 10.1016/j.jchromb.2018.06.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 06/03/2018] [Accepted: 06/04/2018] [Indexed: 02/09/2023]
|
40
|
Van Bael S, Zels S, Boonen K, Beets I, Schoofs L, Temmerman L. A Caenorhabditis elegans Mass Spectrometric Resource for Neuropeptidomics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:879-889. [PMID: 29299835 DOI: 10.1007/s13361-017-1856-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Revised: 11/13/2017] [Accepted: 11/19/2017] [Indexed: 06/07/2023]
Abstract
Neuropeptides are important signaling molecules used by nervous systems to mediate and fine-tune neuronal communication. They can function as neurotransmitters or neuromodulators in neural circuits, or they can be released as neurohormones to target distant cells and tissues. Neuropeptides are typically cleaved from larger precursor proteins by the action of proteases and can be the subject of post-translational modifications. The short, mature neuropeptide sequences often entail the only evolutionarily reasonably conserved regions in these precursor proteins. Therefore, it is particularly challenging to predict all putative bioactive peptides through in silico mining of neuropeptide precursor sequences. Peptidomics is an approach that allows de novo characterization of peptides extracted from body fluids, cells, tissues, organs, or whole-body preparations. Mass spectrometry, often combined with on-line liquid chromatography, is a hallmark technique used in peptidomics research. Here, we used an acidified methanol extraction procedure and a quadrupole-Orbitrap LC-MS/MS pipeline to analyze the neuropeptidome of Caenorhabditis elegans. We identified an unprecedented number of 203 mature neuropeptides from C. elegans whole-body extracts, including 35 peptides from known, hypothetical, as well as from completely novel neuropeptide precursor proteins that have not been predicted in silico. This set of biochemically verified peptide sequences provides the most elaborate C. elegans reference neurpeptidome so far. To exploit this resource to the fullest, we make our in-house database of known and predicted neuropeptides available to the community as a valuable resource. We are providing these collective data to help the community progress, amongst others, by supporting future differential and/or functional studies. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sven Van Bael
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium
| | - Sven Zels
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium
| | - Kurt Boonen
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium
| | - Isabel Beets
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium
| | - Liliane Schoofs
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium
| | - Liesbet Temmerman
- Animal Physiology and Neurobiology, Department of Biology, KU Leuven (University of Leuven), Leuven, Belgium.
| |
Collapse
|
41
|
Ali AS, Raju R, Ray S, Kshirsagar R, Gilbert A, Zang L, Karger BL. Lipidomics of CHO Cell Bioprocessing: Relation to Cell Growth and Specific Productivity of a Monoclonal Antibody. Biotechnol J 2018. [PMID: 29521466 DOI: 10.1002/biot.201700745] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
As the demand for biological therapeutic proteins rises, there is an increasing need for robust and highly efficient bioprocesses, specifically, maximizing protein production by controlling the cellular nutritional and metabolic needs. A comprehensive lipidomics analysis has been performed, for the first time, over the time course of CHO cells producing an IgG1 monoclonal antibody (mAb) with fed batch 5 L bioreactors. The dynamic nature and importance of the CHO lipidome, especially on cellular growth and specific productivity, is demonstrated. A robust LC-MS method using positive and negative mode ESI was developed for lipid identification and quantitation of 377 unique lipids. The analysis revealed large changes in lipid features between the different days in bioprocessing including accumulation of triacylglycerol (TG) and lysophospholipid species with depletion of diacylglycerol (DG) species. Exploring pathway analysis where the lipid data was combined with polar metabolites and transcriptomics (RNA sequencing) revealed differences in lipid metabolism between the various stages of cellular growth and highlighted the role of key features of lipid metabolism on cell growth and specific productivity. The study demonstrates the importance of lipidomics in the expanding role of 'Omics methodologies in gaining insight into cellular behavior during protein production in a fed batch bioprocess.
Collapse
Affiliation(s)
- Amr S Ali
- Cell Culture Development, Biogen, Inc., Cambridge, MA 02142, USA.,Barnett Institute and Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA 02115, USA
| | - Ravali Raju
- Cell Culture Development, Biogen, Inc., Cambridge, MA 02142, USA
| | - Somak Ray
- Barnett Institute and Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA 02115, USA
| | | | - Alan Gilbert
- Cell Culture Development, Biogen, Inc., Cambridge, MA 02142, USA
| | - Li Zang
- Analytical Development, Biogen, Inc., Cambridge, MA 02142, USA
| | - Barry L Karger
- Barnett Institute and Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA 02115, USA
| |
Collapse
|
42
|
Mhlongo MI, Piater LA, Madala NE, Labuschagne N, Dubery IA. The Chemistry of Plant-Microbe Interactions in the Rhizosphere and the Potential for Metabolomics to Reveal Signaling Related to Defense Priming and Induced Systemic Resistance. FRONTIERS IN PLANT SCIENCE 2018; 9:112. [PMID: 29479360 PMCID: PMC5811519 DOI: 10.3389/fpls.2018.00112] [Citation(s) in RCA: 169] [Impact Index Per Article: 28.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 01/22/2018] [Indexed: 05/21/2023]
Abstract
Plant roots communicate with microbes in a sophisticated manner through chemical communication within the rhizosphere, thereby leading to biofilm formation of beneficial microbes and, in the case of plant growth-promoting rhizomicrobes/-bacteria (PGPR), resulting in priming of defense, or induced resistance in the plant host. The knowledge of plant-plant and plant-microbe interactions have been greatly extended over recent years; however, the chemical communication leading to priming is far from being well understood. Furthermore, linkage between below- and above-ground plant physiological processes adds to the complexity. In metabolomics studies, the main aim is to profile and annotate all exo- and endo-metabolites in a biological system that drive and participate in physiological processes. Recent advances in this field has enabled researchers to analyze 100s of compounds in one sample over a short time period. Here, from a metabolomics viewpoint, we review the interactions within the rhizosphere and subsequent above-ground 'signalomics', and emphasize the contributions that mass spectrometric-based metabolomic approaches can bring to the study of plant-beneficial - and priming events.
Collapse
Affiliation(s)
- Msizi I. Mhlongo
- Department of Biochemistry, University of Johannesburg, Johannesburg, South Africa
| | - Lizelle A. Piater
- Department of Biochemistry, University of Johannesburg, Johannesburg, South Africa
| | - Ntakadzeni E. Madala
- Department of Biochemistry, University of Johannesburg, Johannesburg, South Africa
| | - Nico Labuschagne
- Department of Plant and Soil Sciences, University of Pretoria, Pretoria, South Africa
| | - Ian A. Dubery
- Department of Biochemistry, University of Johannesburg, Johannesburg, South Africa
| |
Collapse
|
43
|
Mao XJ, Li J, Liu D, Qiao T, Ma L, Sun X, Xu L, Shi ZG. Flow-through silica: A potential matrix for fast chromatographic enantioseparation with high enantioselectivity. Talanta 2018; 178:583-587. [DOI: 10.1016/j.talanta.2017.09.093] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Revised: 09/18/2017] [Accepted: 09/30/2017] [Indexed: 11/15/2022]
|
44
|
Methodologies to determine b-term coefficients revisited. J Chromatogr A 2018; 1532:124-135. [DOI: 10.1016/j.chroma.2017.11.070] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 10/16/2017] [Accepted: 11/30/2017] [Indexed: 11/19/2022]
|
45
|
Pirok BWJ, Gargano AFG, Schoenmakers PJ. Optimizing separations in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2017; 41:68-98. [PMID: 29027363 PMCID: PMC5814945 DOI: 10.1002/jssc.201700863] [Citation(s) in RCA: 148] [Impact Index Per Article: 21.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 09/21/2017] [Accepted: 09/21/2017] [Indexed: 12/16/2022]
Abstract
Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations.
Collapse
Affiliation(s)
- Bob W J Pirok
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands.,TI-COAST, Science Park, Amsterdam, The Netherlands
| | - Andrea F G Gargano
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands.,Vrije Universiteit Amsterdam, Department of Bioanalytical Chemistry, Amsterdam Institute for Molecules, Medicines and Systems, Amsterdam, The Netherlands
| | - Peter J Schoenmakers
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands
| |
Collapse
|
46
|
Broeckhoven K, Desmet G. Considerations for the use of ultra-high pressures in liquid chromatography for 2.1 mm inner diameter columns. J Chromatogr A 2017; 1523:183-192. [DOI: 10.1016/j.chroma.2017.07.040] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/10/2017] [Accepted: 07/11/2017] [Indexed: 10/19/2022]
|
47
|
Ahmad IAH, Hrovat F, Soliven A, Clarke A, Boswell P, Tarara T, Blasko A. A 14 Parameter Study of UHPLC’s for Method Development Transfer and Troubleshooting. Chromatographia 2017. [DOI: 10.1007/s10337-017-3337-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
48
|
Blue LE, Franklin EG, Godinho JM, Grinias JP, Grinias KM, Lunn DB, Moore SM. Recent advances in capillary ultrahigh pressure liquid chromatography. J Chromatogr A 2017; 1523:17-39. [PMID: 28599863 DOI: 10.1016/j.chroma.2017.05.039] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/12/2017] [Accepted: 05/15/2017] [Indexed: 11/28/2022]
Abstract
In the twenty years since its initial demonstration, capillary ultrahigh pressure liquid chromatography (UHPLC) has proven to be one of most powerful separation techniques for the analysis of complex mixtures. This review focuses on the most recent advances made since 2010 towards increasing the performance of such separations. Improvements in capillary column preparation techniques that have led to columns with unprecedented performance are described. New stationary phases and phase supports that have been reported over the past decade are detailed, with a focus on their use in capillary formats. A discussion on the instrument developments that have been required to ensure that extra-column effects do not diminish the intrinsic efficiency of these columns during analysis is also included. Finally, the impact of these capillary UHPLC topics on the field of proteomics and ways in which capillary UHPLC may continue to be applied to the separation of complex samples are addressed.
Collapse
Affiliation(s)
- Laura E Blue
- Process Development, Amgen Inc., Thousand Oaks, CA 91320, USA
| | - Edward G Franklin
- HPLC Research & Development, Restek Corp., Bellefonte, PA 16823, USA
| | - Justin M Godinho
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - James P Grinias
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, NJ 08028, USA.
| | - Kaitlin M Grinias
- Department of Product Development & Supply, GlaxoSmithKline, King of Prussia, PA 19406, USA
| | - Daniel B Lunn
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | | |
Collapse
|
49
|
Wang J, Zhou L, Lei H, Hao F, Liu X, Wang Y, Tang H. Simultaneous Quantification of Amino Metabolites in Multiple Metabolic Pathways Using Ultra-High Performance Liquid Chromatography with Tandem-mass Spectrometry. Sci Rep 2017; 7:1423. [PMID: 28469184 PMCID: PMC5431165 DOI: 10.1038/s41598-017-01435-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Accepted: 03/28/2017] [Indexed: 01/09/2023] Open
Abstract
Metabolites containing amino groups cover multiple pathways and play important roles in redox homeostasis and biosyntheses of proteins, nucleotides and neurotransmitters. Here, we report a new method for simultaneous quantification of 124 such metabolites. This is achieved by derivatization-assisted sensitivity enhancement with 5-aminoisoquinolyl-N-hydroxysuccinimidyl carbamate (5-AIQC) followed with comprehensive analysis using ultra-high performance liquid chromatography and electrospray ionization tandem mass spectrometry (UHPLC-MS/MS). In an one-pot manner, this quantification method enables simultaneous coverage of 20 important metabolic pathways including protein biosynthesis/degradation, biosyntheses of catecholamines, arginine and glutathione, metabolisms of homocysteine, taurine-hypotaurine etc. Compared with the reported ones, this method is capable of simultaneously quantifying thiols, disulfides and other oxidation-prone analytes in a single run and suitable for quantifying aromatic amino metabolites. This method is also much more sensitive for all tested metabolites with LODs well below 50 fmol (at sub-fmol for most tested analytes) and shows good precision for retention time and quantitation with inter-day and intra-day relative standard deviations (RSDs) below 15% and good recovery from renal cancer tissue, rat urine and plasma. The method was further applied to quantify the amino metabolites in silkworm hemolymph from multiple developmental stages showing its applicability in metabolomics and perhaps some clinical chemistry studies.
Collapse
Affiliation(s)
- Jin Wang
- School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.,State Key Laboratory of Genetic Engineering, Zhongshan Hospital and School of Life Sciences, Fudan University, Shanghai International Centre for Molecular Phenomics, Collaborative Innovation Center for Genetics and Development, Shanghai, 200438, China.,CAS Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, 430071, China
| | - Lihong Zhou
- School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.,CAS Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, 430071, China
| | - Hehua Lei
- CAS Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, 430071, China
| | - Fuhua Hao
- CAS Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, 430071, China
| | - Xin Liu
- School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yulan Wang
- CAS Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan, 430071, China.,Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Zhejiang University, Hangzhou, 310058, China
| | - Huiru Tang
- State Key Laboratory of Genetic Engineering, Zhongshan Hospital and School of Life Sciences, Fudan University, Shanghai International Centre for Molecular Phenomics, Collaborative Innovation Center for Genetics and Development, Shanghai, 200438, China.
| |
Collapse
|
50
|
Column switching UHPLC–MS/MS with restricted access material for the determination of CNS drugs in plasma samples. Bioanalysis 2017; 9:555-568. [DOI: 10.4155/bio-2016-0301] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background: Polypharmacy is a common practice in schizophrenia. Consequently, therapeutic drug monitoring is usually adopted to maintain the concentrations of the drugs in the plasma within a targeted therapeutic range, to maximize therapeutic efficiency and to diminish adverse side effects. Methodology: This study reports on a column switching UHPLC–MS/MS method to determine psychotropic drugs in plasma samples simultaneously. Results: The method was linear from 0.025 to 1.25 ng ml-1 with R2 above 0.9950 and the lack of fit test (p > 0.05). The precision values presented coefficients of variation lower than 12%, and the relative standard error of the accuracy were lower than 14%. Conclusion: The column switching UHPLC–MS/MS method developed herein successfully determined drugs in schizophrenic patients’ plasma samples for therapeutic drug monitoring.
Collapse
|