1
|
Liu CH, Rethi L, Weng PW, Trung Nguyen H, Chuang AEY. Cutting-edge advances in nano/biomedicine: A review on transforming thrombolytic therapy. Biochem Pharmacol 2024; 229:116523. [PMID: 39251141 DOI: 10.1016/j.bcp.2024.116523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 09/03/2024] [Accepted: 09/05/2024] [Indexed: 09/11/2024]
Abstract
Thrombotic blockages within blood vessels give rise to critical cardiovascular disorders, including ischemic stroke, venous thromboembolism, and myocardial infarction. The current approach to the therapy of thrombolysis involves administering Plasminogen Activators (PA), but it is hindered by fast drug elimination, narrow treatment window, and the potential for bleeding complications. Leveraging nanomedicine to encapsulate and deliver PA offers a solution by improving the efficacy of therapy, safeguarding the medicine from proteinase biodegradation, and reducing unwanted effects in in vivo trials. In this review, we delve into the underlying venous as well as arterial thrombus pathophysiology and provide an overview of clinically approved PA used to address acute thrombotic conditions. We explore the existing challenges and potential directions within recent pivotal research on a variety of targeted nanocarriers, such as lipid, polymeric, inorganic, and biological carriers, designed for precise delivery of PA to specific sites. We also discuss the promising role of microbubbles and ultrasound-assisted Sono thrombolysis, which have exhibited enhanced thrombolysis in clinical studies. Furthermore, our review delves into approaches for the strategic development of nano-based carriers tailored for targeting thrombolytic action and efficient encapsulation of PA, considering the intricate interaction in biology systems as well as nanomaterials. In conclusion, the field of nanomedicine offers a valuable method for the exact and effective therapy of severe thrombus conditions, presenting a pathway toward improved patient outcomes and reduced complications.
Collapse
Affiliation(s)
- Chia-Hung Liu
- Department of Urology, School of Medicine, College of Medicine, Taipei Medical University, 250 Wu-Hsing Street, Taipei 11031, Taiwan; TMU Research Center of Urology and Kidney, Taipei Medical University, 250 Wu-Hsing Street, Taipei 11031, Taiwan; Department of Urology, Shuang Ho Hospital, Taipei Medical University, 291 Zhongzheng Road, Zhonghe District, New Taipei City 23561, Taiwan
| | - Lekshmi Rethi
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan; Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
| | - Pei-Wei Weng
- Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City 23561, Taiwan; Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Hieu Trung Nguyen
- Department of Orthopedics and Trauma, Faculty of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, 700000, Viet Nam
| | - Andrew E-Y Chuang
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan; Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan; Cell Physiology and Molecular Image Research Center, Taipei Medical University-Wan Fang Hospital, Taipei 11696, Taiwan.
| |
Collapse
|
2
|
El Kadi S, van de Veerdonk MC, Spoormans EM, Verouden NJW, Li S, Xie F, Azevedo LF, Mathias W, van Rossum AC, Porter TR, Kamp O. Sonothrombolysis in Patients With ST-Elevation Myocardial Infarction With Electrocardiographic No-Reflow After Percutaneous Coronary Intervention: A Randomized Controlled Trial. J Am Soc Echocardiogr 2024; 37:981-992. [PMID: 38972613 DOI: 10.1016/j.echo.2024.06.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 06/21/2024] [Accepted: 06/23/2024] [Indexed: 07/09/2024]
Abstract
BACKGROUND AND AIMS Approximately 50% of patients with ST elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention (PCI) experience microvascular no-reflow. Pre- and post-PCI sonothrombolysis has been shown to decrease infarct size and improve left ventricular (LV) systolic function in STEMI patients receiving urgent PCI. The aim of this study was to investigate whether post-PCI sonothrombolysis alone in STEMI patients with persistent ST elevation could reduce no-reflow and infarct size. METHODS Patients with STEMI with symptoms <12 hours who had persistent ST elevation (≤70% ST resolution) after primary PCI were randomized to sonothrombolysis or control. The primary end point was summed (Σ) ST elevation 60 minutes after study intervention. Secondary end points included infarct size, myocardial perfusion score, LV ejection fraction on cardiovascular magnetic resonance imaging at 2 months follow-up, and clinical outcome at 6-month follow-up. RESULTS Sixty-seven STEMI patients with persistent ST elevation after PCI were randomized (49 left anterior descending, 18 right coronary/left circumflex artery). No difference was observed in Σ ST elevation 60 minutes after study intervention (mean difference, 0.6 mm; 95% CI, -1.1 to 2.2, P = .50). Complete ST resolution occurred in 14 (40%) of patients treated with sonothrombolysis compared to 6 (19%) of controls (P = .16). Myocardial perfusion score index (1.5 ± 0.3 vs 1.5 ± 0.3, P = .93), infarct size (18.0% ± 10% vs 16.8% ± 11%; P = .29) and LV ejection fraction on cardiovascular magnetic resonance (46% ± 8% vs 47% ± 11% in the control group; P = .86) were comparable. Incidence of all-cause death, acute coronary syndrome, and hospital admission for heart failure at 6-month follow-up was similar between the groups (sonothrombolysis, 2; control, 5). CONCLUSIONS In STEMI patients with persistent ST elevation after PCI, post-PCI sonothrombolysis did not result in more ST resolution or smaller infarct size compared to control subjects. The incidence of the combined clinical end points was remarkably low in this high-risk patient population.
Collapse
Affiliation(s)
- Soufiane El Kadi
- Amsterdam UMC, Location VUmc, Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands.
| | | | - Eva M Spoormans
- Amsterdam UMC, Location VUmc, Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Niels J W Verouden
- Amsterdam UMC, Location VUmc, Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Shouqiang Li
- Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Feng Xie
- Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | | | - Wilson Mathias
- Heart Institute (InCor), University of São Paulo, Medical School, São Paulo, Brazil
| | - Albert C van Rossum
- Amsterdam UMC, Location VUmc, Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Thomas R Porter
- Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Otto Kamp
- Amsterdam UMC, Location VUmc, Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| |
Collapse
|
3
|
George Mathen P, Krupa J, Samson N, Mirza S, Raja H, Selvaraj S, Jose J. Safety, feasibility and efficacy of sonothrombolysis with micro boluses of perfluoropropane as a point of care therapy for patients with acute ST-elevation myocardial infarction. J R Coll Physicians Edinb 2024; 54:197-203. [PMID: 39136288 DOI: 10.1177/14782715241273737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2024] Open
Abstract
BACKGROUND Despite advances in timely revascularisation of ST elevation myocardial infarction (STEMI) patients, there are several practical and unavoidable delays. Sonothrombolysis (administered during micro boluses of Perfluoropropane) initiated bedside as a point-of-care therapy during the initial evaluation of the patient may potentially mitigate this by producing early culprit vessel revascularisation. METHODS This was a prospective, single-centre study on hemodynamically stable patients presenting within 12 hours of a first STEMI who consented for study participation. RESULTS Fifteen patients were recruited over a 1-month period. Eleven were male. Nine patients had anterior wall STEMI and left anterior descending as culprit vessel. There were no significant changes in safety outcomes. Median First Medical Contact (FMC)-Sono time was 12 min (10-15). Median duration of sonothrombolysis was 14 min (12-16). FMC-device time was 97 min (79-128). Six patients had culprit vessel recanalisation before primary percutaneous coronary intervention (PPCI) which was consistent with the reference rates of therapy-associated recanalisation (p = 0.535). CONCLUSION Micro bolus sonothrombolysis maybe safely initiated as a point of care therapy adjunctive to PPCI in hemodynamically stable STEMI patients with reasonable efficacy. Further randomised trials are needed to ascertain its applicability in various geographical and clinical settings.
Collapse
Affiliation(s)
| | - Jesu Krupa
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| | - Nathaniel Samson
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| | - Shohiab Mirza
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| | - Haynes Raja
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| | - Sakthivel Selvaraj
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| | - John Jose
- Department of Cardiology, Christian Medical College and Hospital, Vellore, TN, India
| |
Collapse
|
4
|
Yang S, Zemzemi C, Escudero DS, Vela DC, Haworth KJ, Holland CK. Histotripsy and Catheter-Directed Lytic: Efficacy in Highly Retracted Porcine Clots In Vitro. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1167-1177. [PMID: 38777639 DOI: 10.1016/j.ultrasmedbio.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 04/02/2024] [Accepted: 04/05/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVE Standard treatment for deep vein thrombosis (DVT) involves catheter-directed anticoagulants or thrombolytics, but the chronic thrombi present in many DVT cases are often resistant to this therapy. Histotripsy has been found to be a promising adjuvant treatment, using the mechanical action of cavitating bubble clouds to enhance thrombolytic activity. The objective of this study was to determine if histotripsy enhanced recombinant tissue plasminogen activator (rt-PA) thrombolysis in highly retracted porcine clots in vitro in a flow model of occlusive DVT. METHODS Highly retracted porcine whole blood clots were treated for 1 h with either catheter-directed saline (negative control), rt-PA (lytic control), histotripsy, DEFINITY and histotripsy or the combination of rt-PA and histotripsy with or without DEFINITY. Five-cycle, 1.5 MHz histotripsy pulses with a peak negative pressure of 33.2 MPa and pulse repetition frequency of 40 Hz were applied along the clot. B-Mode and passive cavitation images were acquired during histotripsy insonation to monitor bubble activity. RESULTS Clots subjected to histotripsy with and without rt-PA exhibited greater thrombolytic efficacy than controls (7.0% flow recovery or lower), and histotripsy with rt-PA was more efficacious than histotripsy with saline (86.1 ± 10.2% compared with 61.7 ± 19.8% flow recovery). The addition of DEFINITY to histotripsy with or without rt-PA did not enhance either thrombolytic efficacy or cavitation dose. Cavitation dose generally did not correlate with thrombolytic efficacy. CONCLUSION Enhancement of thrombolytic efficacy was achieved using histotripsy, with and without catheter-directed rt-PA, in the presence of physiologic flow. This suggests these treatments may be effective as therapy for DVT.
Collapse
Affiliation(s)
- Shumeng Yang
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Chadi Zemzemi
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA
| | | | - Deborah C Vela
- Cardiovascular Pathology, Texas Heart Institute, Houston, TX, USA
| | - Kevin J Haworth
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Christy K Holland
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
5
|
Samaddar A, Singh R, Yang X, Ebersole KC, Forrest ML. Investigating the potential of catheter-assisted pulsed focused ultrasound ablation for atherosclerotic plaques. Med Phys 2024; 51:5181-5189. [PMID: 38873842 PMCID: PMC11409400 DOI: 10.1002/mp.17253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/15/2024] Open
Abstract
BACKGROUND Atherosclerosis is a condition in which an adhesive substance called plaque accumulates over time inside the arteries. Plaque buildup results in the constriction of arteries, causing a shortage of blood supply to tissues and organs. Removing atherosclerotic plaques controls the development of acute ischemic stroke and heart diseases. It remains imperative for positive patient outcomes. PURPOSE This study sought to develop a minimally invasive technique for removing arterial plaques by applying focused ultrasound (FUS) energy on the metal surface of a nitinol catheter wire to induce inertial cavitation. The induced cavitation can deplete plaque mechanically inside the arteries, leading towards improved recanalization of blood vessels. METHODS The enhanced cavitation effect induced by combining FUS with a metal catheter was first verified by exposing agar phantom gels with or without a 0.9-mm diameter nitinol wire to an acoustic field produced by a 0.5-MHz FUS transducer. The phenomenon was further confirmed in pork belly fat samples with or without a 3-mm diameter nitinol catheter wire. Cavitation was monitored by detecting the peaks of emitted ultrasound signals from the samples using a passive cavitation detector (PCD). Cavitation threshold values were determined by observing the jump in the peak amplitude of signals received by the PCD when the applied FUS peak negative pressure (PNP) increased. To simulate arterial plaque removal, FUS with or without a catheter was used to remove tissues from pork belly fat samples and the lipid cores of human atherosclerotic plaque samples using 2500-cycle FUS bursts at 10% duty cycle and a burst repetition rate of 20 Hz. Treatment outcomes were quantified by subtracting the weight of samples before treatment from the weight of samples after treatment. All measurements were repeated 5 times (n = 5) unless otherwise indicated, and paired t-tests were used to compare the means of two groups. A p-value of <0.05 will be considered significant. RESULTS Our results showed that with a nitinol wire, the cavitation threshold in agar phantoms was reduced to 2.6 MPa from 4.3 MPa PNP when there was no nitinol wire in the focal region of FUS. For pork belly fat samples, cavitation threshold values were 1.0 and 2.0 MPa PNP, with and without a catheter wire, respectively. Pork belly fat tissues and lipid cores of atherosclerotic plaques were depleted at the interface between a catheter and the samples at 2 and 4 MPa FUS PNP, respectively. The results showed that with a catheter wire in the focal region of a 3-min FUS treatment session, 24.7 and 25.6 mg of lipid tissues were removed from pork belly fat and human atherosclerotic samples, respectively. In contrast, the FUS-only group showed no reduction in sample weight. The differences between FUS-only and FUS-plus-catheter groups were statistically significant (p < 0.001 for the treatment on pork belly samples, and p < 0.01 for the treatment on human atherosclerotic samples). CONCLUSION This study demonstrated the feasibility of catheter-assisted FUS therapy for removing atherosclerotic plaques.
Collapse
Affiliation(s)
- Abhirup Samaddar
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Rohit Singh
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Xinmai Yang
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Koji C Ebersole
- Department of Neurosurgery, the University of Kansas Medical Center, Kansas City, Kansas, USA
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, the University of Kansas, Lawrence, Kansas, USA
| |
Collapse
|
6
|
Víteček J, Vítečková Wünschová A, Thalerová S, Gulati S, Kubala L, Capandová M, Hampl A, Robert Mikulík. Factors influencing the efficacy of recombinant tissue plasminogen activator: Implications for ischemic stroke treatment. PLoS One 2024; 19:e0302269. [PMID: 38843177 PMCID: PMC11156348 DOI: 10.1371/journal.pone.0302269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 03/31/2024] [Indexed: 06/09/2024] Open
Abstract
Intravenous thrombolysis with a recombinant tissue plasminogen activator (rt-PA) is the first-line treatment of acute ischemic stroke. However, successful recanalization is relatively low and the underlying processes are not completely understood. The goal was to provide insights into clinically important factors potentially limiting rt-PA efficacy such as clot size, rt-PA concentration, clot age and also rt-PA in combination with heparin anticoagulant. We established a static in vitro thrombolytic model based on red blood cell (RBC) dominant clots prepared using spontaneous clotting from the blood of healthy donors. Thrombolysis was determined by clot mass loss and by RBC release. The rt-PA became increasingly less efficient for clots larger than 50 μl at a clinically relevant concentration of 1.3 mg/l. A tenfold decrease or increase in concentration induced only a 2-fold decrease or increase in clot degradation. Clot age did not affect rt-PA-induced thrombolysis but 2-hours-old clots were degraded more readily due to higher activity of spontaneous thrombolysis, as compared to 5-hours-old clots. Finally, heparin (50 and 100 IU/ml) did not influence the rt-PA-induced thrombolysis. Our study provided in vitro evidence for a clot size threshold: clots larger than 50 μl are hard to degrade by rt-PA. Increasing rt-PA concentration provided limited thrombolytic efficacy improvement, whereas heparin addition had no effect. However, the higher susceptibility of younger clots to thrombolysis may prompt a shortened time from the onset of stroke to rt-PA treatment.
Collapse
Affiliation(s)
- Jan Víteček
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Biophysics of Immune System, Institute of Biophysics of the Czech Academy of Sciences, Brno, Czech Republic
| | - Andrea Vítečková Wünschová
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Department of Anatomy, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Sandra Thalerová
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Biophysics of Immune System, Institute of Biophysics of the Czech Academy of Sciences, Brno, Czech Republic
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Sumeet Gulati
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Biophysics of Immune System, Institute of Biophysics of the Czech Academy of Sciences, Brno, Czech Republic
| | - Lukáš Kubala
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Biophysics of Immune System, Institute of Biophysics of the Czech Academy of Sciences, Brno, Czech Republic
| | - Michaela Capandová
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Aleš Hampl
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Robert Mikulík
- International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic
| |
Collapse
|
7
|
Feng S, Wang S, Tang J, Zhu X. Ultrasound Combined With Continuous Microbubble Injection to Enhance Catheter-Directed Thrombolysis in Vitro and in Vivo. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:741-749. [PMID: 38158852 DOI: 10.1002/jum.16400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 11/23/2023] [Accepted: 12/12/2023] [Indexed: 01/03/2024]
Abstract
OBJECTIVES To investigate the influence of microbubble perfusion mode on catheter-directed thrombolysis (CDT), we evaluated the effect of two different types of microbubble perfusion modes (continuous injection versus bolus injection) on the thrombolytic efficacy of CDT in vitro and further assessed the effect of continuous microbubble injection on CDT in vivo. METHODS In an in vitro experimental setup, 50 fresh bovine whole blood clots were randomized into five groups: ultrasound and continuous microbubble injection-enhanced CDT (US + cMB + CDT), ultrasound and bolus microbubble injection-enhanced CDT (US + bMB + CDT), US + CDT, US + cMB, and CDT. In a porcine femoral vein thrombosis model, 16 completely obstructive thrombi were randomly assigned to the CDT group and the US + cMB + CDT group, respectively. Thrombolysis rate, vascular recanalization rate, hematoxylin-eosin, and immunofluorescence staining were used to evaluate the thrombolytic effect in vitro and in vivo. RESULTS In vitro, US + cMB + CDT group resulted in a significantly higher thrombolysis rate compared with the other four groups (P < .05). Meanwhile, this group also demonstrated a looser clot structure and more disrupted fibrin structures. In vivo, US + cMB + CDT contributed to a significantly higher vascular recanalization rate compared with CDT (87.50% versus 25.00%, P < .05). CONCLUSIONS US + cMB + CDT was more effective than US + bMB + CDT in thrombolysis, and ultrasound combined with continuous microbubble injection could enhance the thrombolytic efficacy of CDT.
Collapse
Affiliation(s)
- Shuang Feng
- Department of Ultrasound, General Hospital of Southern Theatre Command, Guangzhou, China
| | - Shan Wang
- Department of Ultrasound, Huizhou Central People's Hospital, Huizhou, China
| | - Jiawei Tang
- Department of Ultrasound, General Hospital of Southern Theatre Command, Guangzhou, China
| | - Xiansheng Zhu
- Department of Ultrasound, General Hospital of Southern Theatre Command, Guangzhou, China
| |
Collapse
|
8
|
Gong L, Wright AR, Hynynen K, Goertz DE. Inducing cavitation within hollow cylindrical radially polarized transducers for intravascular applications. ULTRASONICS 2024; 138:107223. [PMID: 38553135 DOI: 10.1016/j.ultras.2023.107223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/31/2023] [Accepted: 12/12/2023] [Indexed: 04/02/2024]
Abstract
Thrombotic occlusions of large blood vessels are increasingly treated with catheter based mechanical approaches, one of the most prominent being to employ aspiration to extract clots through a hollow catheter lumen. A central technical challenge for aspiration catheters is to achieve sufficient suction force to overcome the resistance of clot material entering into the distal tip. In this study, we examine the feasibility of inducing cavitation within hollow cylindrical transducers with a view to ultimately using them to degrade the mechanical integrity of thrombus within the tip of an aspiration catheter. Hollow cylindrical radially polarized PZT transducers with 3.3/2.5 mm outer/inner diameters were assessed. Finite element simulations and hydrophone experiments were used to investigate the pressure field distribution as a function of element length and resonant mode (thickness, length). Operating in thickness mode (∼5 MHz) was found to be associated with the highest internal pressures, estimated to exceed 23 MPa. Cavitation was demonstrated to be achievable within the transducer under degassed water (10 %) conditions using hydrophone detection and high-frequency ultrasound imaging (40 MHz). Cavitation clouds occupied a substantial portion of the transducer lumen, in a manner that was dependent on the pulsing scheme employed (10 and 100 μs pulse lengths; 1.1, 11, and 110 ms pulse intervals). Collectively the results support the feasibility of achieving cavitation within a transducer compatible with mounting in the tip of an aspiration format catheter.
Collapse
Affiliation(s)
- Li Gong
- Department of Medical Biophysics, University of Toronto, Canada; Physical Sciences Platform, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Canada.
| | - Alex R Wright
- Physical Sciences Platform, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Kullervo Hynynen
- Department of Medical Biophysics, University of Toronto, Canada; Physical Sciences Platform, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | - David E Goertz
- Department of Medical Biophysics, University of Toronto, Canada; Physical Sciences Platform, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Canada
| |
Collapse
|
9
|
Zhou S, Li J, Chen X, Huang B, Lu D, Zhang T. Mediation of long-pulsed ultrasound enhanced microbubble recombinant tissue plasminogen activator thrombolysis in a rat model of platelet-rich thrombus. Cardiovasc Diagn Ther 2024; 14:51-58. [PMID: 38434566 PMCID: PMC10904306 DOI: 10.21037/cdt-23-356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 12/29/2023] [Indexed: 03/05/2024]
Abstract
Background Ultrasound (US)-enhanced microbubble (MB) therapy has been investigated as a therapeutic technique to facilitate the thrombolysis for the treatment of pericardial and microvascular obstruction. This study sought to assess the therapeutic effects of long-pulsed US-assisted MB-mediated recombinant tissue plasminogen activator (rt-PA) thrombolysis in a rat model of platelet-rich thrombus. Methods Ferric chloride (10%) was used to induce total arterial occlusion before formation of platelet-rich thrombi. Therapeutic long-tone-burst US (1 MHz, 0.6 MPa, 1,000-µs pulse length) was used, and 2.9×109/mL of lipid MBs and 1 mg/mL of rt-PA were infused. Subsequently, 42 Sprague-Dawley (SD) male rats were randomly divided into seven groups: (I) control; (II) rt-PA; (III) high duty cycle US + MB; (IV) low duty cycle US + rt-PA; (V) high duty cycle US + rt-PA; (VI) low duty cycle US + rt-PA + MB; and (VII) high duty cycle US + rt-PA + MB. The recanalization grades were evaluated after 20 minutes' treatment. Results Compared to the control, there was significant improvement in recanalization in the US + rt-PA groups (P=0.01 vs. control), US (low duty cycle) + rt-PA + MB (P=0.003 vs. control) and US (high duty cycle) + rt-PA + MB (P<0.001 vs. control) groups, in which recanalization was successfully achieved in all rats. Conclusions Long-pulsed US-enhanced MB-mediated rt-PA thrombolysis offered a powerful approach in the treatment of platelet-rich thrombus.
Collapse
Affiliation(s)
- Shuxuan Zhou
- Department of Cardiology, the First Affiliated Hospital of Jinan University, Guangzhou, China
- Cardiovascular Center, Hospital of Changan Dongguan, Dongguan, China
| | - Jinhua Li
- Department of Ultrasound, the First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Xianghui Chen
- Department of Cardiology, the First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Bihan Huang
- Department of Cardiology, the First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Dan Lu
- Department of Neurology and Stroke Center, the First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Tao Zhang
- Department of Cardiology, the First Affiliated Hospital of Jinan University, Guangzhou, China
| |
Collapse
|
10
|
Suarez Escudero D, Haworth KJ, Genstler C, Holland CK. Quantifying the Effect of Acoustic Parameters on Temporal and Spatial Cavitation Activity: Gauging Cavitation Dose. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2388-2397. [PMID: 37648590 PMCID: PMC10581030 DOI: 10.1016/j.ultrasmedbio.2023.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 07/28/2023] [Accepted: 08/01/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVE Cavitation-enhanced delivery of therapeutic agents is under development for the treatment of cancer and neurodegenerative and cardiovascular diseases, including sonothrombolysis for deep vein thrombosis. The objective of this study was to quantify the spatial and temporal distribution of cavitation activity nucleated by Definity infused through the EKOS catheter over a range of acoustic parameters controlled by the EKOS endovascular system. METHODS Three insonation protocols were compared in an in vitro phantom mimicking venous flow to measure the effect of peak rarefactional pressure, pulse duration and pulse repetition frequency on cavitation activity energy, location and duration. Inertial and stable cavitation activity was quantified using passive cavitation imaging, and a metric of cavitation dose based on energy density was defined. RESULTS For all three insonation protocols, cavitation was sustained for the entire 30 min Definity infusion. The evolution of cavitation energy during each pulse duration was similar for all three protocols. For insonation protocols with higher peak rarefactional acoustic pressures, inertial and stable cavitation doses also increased. A complex relationship between the temporal behavior of cavitation energy within each pulse and the pulse repetition frequency affected the cavitation dose for the three insonation protocols. The relative predominance of stable or inertial cavitation dose varied according to insonation schemes. Passive cavitation images revealed the spatial distribution of cavitation activity. CONCLUSION Our cavitation dose metric based on energy density enabled the impact of different acoustic parameters on cavitation activity to be measured. Depending on the type of cavitation to be promoted or suppressed, particular pulsing schemes could be employed in future studies, for example, to correlate cavitation dose with sonothrombolytic efficacy.
Collapse
Affiliation(s)
- Daniel Suarez Escudero
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Kevin J Haworth
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | | | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
| |
Collapse
|
11
|
Chen X, Chen X, Wang J, Yu FTH, Villanueva FS, Pacella JJ. Dynamic Behavior of Polymer Microbubbles During Long Ultrasound Tone-Burst Excitation and Its Application for Sonoreperfusion Therapy. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:996-1006. [PMID: 36697268 PMCID: PMC9974862 DOI: 10.1016/j.ultrasmedbio.2022.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 12/19/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVE Ultrasound (US)-targeted microbubble (MB) cavitation (UTMC)-mediated therapies have been found to restore perfusion and enhance drug/gene delivery. Because of the potentially longer circulation time and relative ease of storage and reconstitution of polymer-shelled MBs compared with lipid MBs, we investigated the dynamic behavior of polymer microbubbles and their therapeutic potential for sonoreperfusion (SRP) therapy. METHODS The fate of polymer MBs during a single long tone-burst exposure (1 MHz, 5 ms) at various acoustic pressures and MB concentrations was recorded via high-speed microscopy and passive cavitation detection (PCD). SRP efficacy of the polymer MBs was investigated in an in vitro flow system and compared with that of lipid MBs. DISCUSSION Microscopy videos indicated that polymer MBs formed gas-filled clusters that continued to oscillate, fragment and form new gas-filled clusters during the single US burst. PCD confirmed continued acoustic activity throughout the 5-ms US excitation. SRP efficacy with polymer MBs increased with pulse duration and acoustic pressure similarly to that with lipid MBs but no significant differences were found between polymer and lipid MBs. CONCLUSION These data suggest that persistent cavitation activity from polymer MBs during long tone-burst US excitation confers excellent reperfusion efficacy.
Collapse
Affiliation(s)
- Xianghui Chen
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA; Department of Cardiology, First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Xucai Chen
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Jianjun Wang
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Francois T H Yu
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Flordeliza S Villanueva
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - John J Pacella
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
| |
Collapse
|
12
|
Zhou S, Zhao W, Hu J, Mao C, Zhou M. Application of Nanotechnology in Thrombus Therapy. Adv Healthc Mater 2023; 12:e2202578. [PMID: 36507827 DOI: 10.1002/adhm.202202578] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 11/26/2022] [Indexed: 12/14/2022]
Abstract
A thrombus is a blood clot that forms in the lumen of an artery or vein, restricting blood flow and causing clinical symptoms. Thrombosis is associated with many life-threatening cardiovascular diseases. However, current clinical therapeutic technologies still have many problems in targeting, enrichment, penetration, and safety to meet the thrombosis treatment needs. Therefore, researchers devote themselves to developing nanosystems loaded with antithrombotic drugs to address this paradox in recent years. Herein, the existing thrombosis treatment technologies are first reviewed; and then, their advantages and disadvantages are outlined based on a brief discussion of thrombosis's definition and formation mechanism. Furthermore, the need and application cases for introducing nanotechnology are discussed, focusing on thrombus-specific targeted ligand modification technology and microenvironment-triggered responsive drug release technology. Then, nanomaterials that can be used to design antithrombotic nanotherapeutic systems are summarized. Moreover, a variety of drug delivery technologies driven by nanomotors in thrombosis therapy is also introduced. Last of all, a prospective discussion on the future development of nanotechnology for thrombosis therapy is highlighted.
Collapse
Affiliation(s)
- Shuyin Zhou
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China.,Department of Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Wenbo Zhao
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Jinglei Hu
- Kuang Yaming Honors School, Nanjing University, Nanjing, 210023, China
| | - Chun Mao
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Min Zhou
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| |
Collapse
|
13
|
Kleven RT, Huang S, Ford SM, Sakthivel K, Thomas SR, Zuccarello M, Herr AB, Holland CK. Effect of Recombinant Tissue Plasminogen Activator and 120-kHz Ultrasound on Porcine Intracranial Thrombus Density. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:539-548. [PMID: 36336551 DOI: 10.1016/j.ultrasmedbio.2022.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 10/04/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Surgical intervention for the treatment of intracerebral hemorrhage (ICH) has been limited by inadequate lysis of the target thrombus. Adjuvant transcranial ultrasound exposure is hypothesized to improve thrombolysis, expedite hematoma evacuation and improve clinical outcomes. A juvenile porcine intracerebral hemorrhage model was established by direct infusion of autologous blood into the porcine white matter. Thrombi were either not treated (sham) or treated with recombinant tissue plasminogen activator alone (rt-PA only) or in combination with pulsed transcranial 120-kHz ultrasound (sonothrombolysis). After treatment, pigs were euthanized, the heads frozen and sectioned and the thrombi extracted. D-Dimer and thrombus density assays were used to assess degree of lysis. Both porcine and human D-dimer assays tested did not have sufficient sensitivity to detect porcine D-dimer. Thrombi treated with rt-PA with or without 120-kHz ultrasound had a significantly lower density compared with sham-treated thrombi. No enhancement of rt-PA-mediated thrombolysis was noted with the addition of 120-kHz ultrasound (sonothrombolysis). The thrombus density assay revealed thrombolytic efficacy caused by rt-PA in an in vivo juvenile porcine model of intracerebral hemorrhage. Transcranial sonothrombolysis did not enhance rt-PA-induced thrombolysis, likely because of the lack of exogenous cavitation nuclei.
Collapse
Affiliation(s)
- Robert T Kleven
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Shenwen Huang
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Samantha M Ford
- Neuroscience Program, College of Arts and Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Karthikeyan Sakthivel
- Medical Sciences Program, College of Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Seth R Thomas
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA
| | - Mario Zuccarello
- Department of Neurosurgery, University of Cincinnati, Cincinnati, Ohio, USA
| | - Andrew B Herr
- Division of Immunobiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|
14
|
Choi W, Cho H, Kim G, Youn I, Key J, Han S. Targeted thrombolysis by magnetoacoustic particles in photothrombotic stroke model. Biomater Res 2022; 26:58. [PMID: 36273198 PMCID: PMC9587564 DOI: 10.1186/s40824-022-00298-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 09/14/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Recombinant tissue plasminogen activator (rtPA) has a short half-life, and additional hemorrhagic transformation (HT) can occur when treatment is delayed. Here, we report the design and thrombolytic performance of 3 [Formula: see text]m discoidal polymeric particles loaded with rtPA and superparamagnetic iron oxide nanoparticles (SPIONs), referred to as rmDPPs, to address the HT issues of rtPA. METHODS The rmDPPs consisted of a biodegradable polymeric matrix, rtPA, and SPIONs and were synthesized via a top-down fabrication. RESULTS The rmDPPs could be concentrated at the target site with magnetic attraction, and then the rtPA could be released under acoustic stimulus. Therefore, we named that the particles had magnetoacoustic properties. For the in vitro blood clot lysis, the rmDPPs with magnetoacoustic stimuli could not enhance the lytic potential compared to the rmDPPs without stimulation. Furthermore, although the reduction of the infarcts in vivo was observed along with the magnetoacoustic stimuli in the rmDPPs, more enhancement was not achieved in comparison with the rtPA. A notable advantage of rmDPPs was shown in delayed administration of rmDPPs at poststroke. The late treatment of rmDPPs with magnetoacoustic stimuli could reduce the infarcts and lead to no additional HT issues, while rtPA alone could not show any favorable prognosis. CONCLUSION The rmDPPs may be advantageous in delayed treatment of thrombotic patients.
Collapse
Affiliation(s)
- Wonseok Choi
- Biomedical Research Division, Korea Institute of Science and Technology, Seoul, Republic of Korea.,Department of Biomedical Engineering, Yonsei University, Wonju, Republic of Korea
| | - Hyeyoun Cho
- Department of Biomedical Engineering, Yonsei University, Wonju, Republic of Korea
| | - Gahee Kim
- Department of Biomedical Engineering, Yonsei University, Wonju, Republic of Korea
| | - Inchan Youn
- Biomedical Research Division, Korea Institute of Science and Technology, Seoul, Republic of Korea.,Divison of Bio-Medical Science & Technology, Korea Institute of Science and Technology School, Seoul, Republic of Korea.,KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul, Republic of Korea
| | - Jaehong Key
- Department of Biomedical Engineering, Yonsei University, Wonju, Republic of Korea.
| | - Sungmin Han
- Biomedical Research Division, Korea Institute of Science and Technology, Seoul, Republic of Korea. .,Divison of Bio-Medical Science & Technology, Korea Institute of Science and Technology School, Seoul, Republic of Korea.
| |
Collapse
|
15
|
Wen Y, Guo D, Zhang J, Liu X, Liu T, Li L, Jiang S, Wu D, Jiang H. Clinical photoacoustic/ultrasound dual-modal imaging: Current status and future trends. Front Physiol 2022; 13:1036621. [PMID: 36388111 PMCID: PMC9651137 DOI: 10.3389/fphys.2022.1036621] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 10/05/2022] [Indexed: 08/24/2023] Open
Abstract
Photoacoustic tomography (PAT) is an emerging biomedical imaging modality that combines optical and ultrasonic imaging, providing overlapping fields of view. This hybrid approach allows for a natural integration of PAT and ultrasound (US) imaging in a single platform. Due to the similarities in signal acquisition and processing, the combination of PAT and US imaging creates a new hybrid imaging for novel clinical applications. Over the recent years, particular attention is paid to the development of PAT/US dual-modal systems highlighting mutual benefits in clinical cases, with an aim of substantially improving the specificity and sensitivity for diagnosis of diseases. The demonstrated feasibility and accuracy in these efforts open an avenue of translating PAT/US imaging to practical clinical applications. In this review, the current PAT/US dual-modal imaging systems are discussed in detail, and their promising clinical applications are presented and compared systematically. Finally, this review describes the potential impacts of these combined systems in the coming future.
Collapse
Affiliation(s)
- Yanting Wen
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
- School of Computer Science and Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Dan Guo
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
| | - Jing Zhang
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
- School of Computer Science and Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Xiaotian Liu
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
| | - Ting Liu
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
| | - Lu Li
- Department of Ultrasound Imaging, The Fifth People’s Hospital of Chengdu, Chengdu, China
| | - Shixie Jiang
- Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, Stanford, CA, United States
| | - Dan Wu
- School of Computer Science and Technology, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Huabei Jiang
- Department of Medical Engineering, University of South Florida, Tampa, FL, United States
| |
Collapse
|
16
|
Zhang J, Zheng T, Tang L, Qi H, Wu X, Zhu L. Bubble-Enhanced Mixing Induced by Standing Surface Acoustic Waves (SSAWs) in Microchannel. MICROMACHINES 2022; 13:mi13081337. [PMID: 36014259 PMCID: PMC9414155 DOI: 10.3390/mi13081337] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/08/2022] [Accepted: 08/15/2022] [Indexed: 05/21/2023]
Abstract
BAW-based micromixers usually achieve mixing enhancement with acoustic-induced bubbles, while SAW-based micromixers usually enhance mixing efficiency by varying the configuration of IDTs and microchannels. In this paper, bubble-enhanced acoustic mixing induced by standing surface acoustic waves (SSAWs) in a microchannel is proposed and experimentally demonstrated. Significant enhancement in the mixing efficiency was achieved after the bubbles were stimulated in our acoustofluidic microdevice. With an applied voltage of 5 V, 50 times amplified, the proposed mixing microdevice could achieve 90.8% mixing efficiency within 60 s at a flow rate of 240 μL/h. The bubbles were generated from acoustic cavitation assisted by the temperature increase resulting from the viscous absorption of acoustic energy. Our results also suggest that a temperature increase is harmful to microfluidic devices and temperature monitoring. Regulation is essential, especially in chemical and biological applications.
Collapse
Affiliation(s)
- Jingjing Zhang
- School of Mechatronics Engineering, Xi’an Technological University, Xi’an 710021, China
- Correspondence:
| | - Tengfei Zheng
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China
- Shaanxi Key Laboratory of Intelligent Robots, Xi’an Jiaotong University, Xi’an 710049, China
| | - Lin Tang
- School of Mechatronics Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Hui Qi
- School of Mechatronics Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Xiaoyu Wu
- School of Mechatronics Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Linlong Zhu
- School of Mechatronics Engineering, Xi’an Technological University, Xi’an 710021, China
| |
Collapse
|
17
|
Wang Z, Pan Y, Huang H, Zhang Y, Li Y, Zou C, Huang G, Chen Y, Li Y, Li J, Chen H. Enhanced thrombolysis by endovascular low-frequency ultrasound with bifunctional microbubbles in venous thrombosis: in vitro and in vivo study. Front Bioeng Biotechnol 2022; 10:965769. [PMID: 35942007 PMCID: PMC9356075 DOI: 10.3389/fbioe.2022.965769] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 06/27/2022] [Indexed: 11/13/2022] Open
Abstract
There is a need to improve the efficacy and safety of endovascular techniques in venous thrombotic diseases, and microbubble enhanced sonothrombolysis is a promising approach. However, whether endovascular low-frequency ultrasound (LFUS) can be utilized in microbubble enhanced sonothrombolysis is unclear. Here, we present a catheter-based thrombolytic system that combines unfocused low-frequency low-intensity ultrasound with novel fibrin-targeted drug-loaded bifunctional microbubbles. We develop an in vitro flow model and an in vivo rabbit inferior vena cava (IVC) thrombosis model to evaluate the safety and efficacy of the thrombolytic system. The results indicate that microbubble enhanced sonothrombolysis with endovascular LFUS treatment for 30 min is equally effective compared to pure pharmacologic treatment. Furthermore, the thrombolytic efficacy of this system is safely and substantially improved by the introduction of a fibrin-targeted drug-loaded bifunctional microbubble with a reduction of the fibrinolytic agent dosage by 60%. The microbubble enhanced endovascular LFUS sonothrombolysis system with excellent thrombolytic efficacy may serve as a new therapeutic approach for venous thrombotic diseases.
Collapse
Affiliation(s)
- Zhaojian Wang
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yunfan Pan
- State Key Laboratory of Tribology, Tsinghua University, Beijing, China
| | - Huaigu Huang
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuan Zhang
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, China
| | - Yan Li
- State Key Laboratory of Tribology, Tsinghua University, Beijing, China
| | - Chenghong Zou
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, China
| | - Guanghua Huang
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuexin Chen
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- *Correspondence: Yuexin Chen, ; Yongjian Li,
| | - Yongjian Li
- State Key Laboratory of Tribology, Tsinghua University, Beijing, China
- *Correspondence: Yuexin Chen, ; Yongjian Li,
| | - Jiang Li
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, China
| | - Haosheng Chen
- State Key Laboratory of Tribology, Tsinghua University, Beijing, China
| |
Collapse
|
18
|
Adzerikho I, Kulak A, Rachok S, Minchenya V. Dependence of the Rate and Completeness of Fibrin Clot Destruction on the Acoustic Dose and Ultrasound Intensity. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:846-855. [PMID: 35177275 DOI: 10.1016/j.ultrasmedbio.2022.01.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 01/05/2022] [Accepted: 01/07/2022] [Indexed: 06/14/2023]
Abstract
The kinetics of fibrin clot destruction under catheter-delivered 32- to 45-kHz ultrasound (US) has been studied at 36°C-38°C in isotonic saline solution. A pseudo-first-order rate constant increased linearly from 0.06/min to 0.57/min with increasing US intensity I0 from 21.6 to 51.2 W/cm2. At I0 = 4.4 and 11.4 W/cm2, the degree of clot destruction did not exceed 11%-15% regardless of the time of US exposure. Starting from I0 = 21.6 W/cm2, the maximum achievable level of clot destruction increased linearly with US intensity, reaching 68% at I0 = 51.2 W/cm2 after 3 min of US exposure. Thus, US intensity is a key parameter determining the maximum achievable level of clot destruction. However, an increase in US intensity above 30 W/cm2 is limited by the intensified negative sonochemical effect on the enzymatic system of hemostasis caused by an increase in inertial cavitation. The best effect can be achieved with ultrasound of a sufficiently high intensity that ensures a large contribution of stable cavitation, generating microstreaming flows, and a minimum contribution of inertial cavitation, generating microjets and shock waves.
Collapse
Affiliation(s)
- Igor Adzerikho
- State Higher Educational Establishment "Belarusian Medical Academy of Postgraduate Education", Minsk, Belarus
| | - Anatoly Kulak
- Institute of General and Inorganic Chemistry, National Academy of Sciences of Belarus, Minsk, Belarus.
| | - Svetlana Rachok
- State Higher Educational Establishment "Belarusian Medical Academy of Postgraduate Education", Minsk, Belarus
| | | |
Collapse
|
19
|
Dadgar MM, Hynynen K. High-Pressure Low-Frequency Lateral Mode Phased-Array Transducer System for the Treatment of Deep Vein Thrombosis: An In Vitro Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1088-1099. [PMID: 35020593 DOI: 10.1109/tuffc.2022.3141871] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Deep vein thrombosis (DVT) can lead to a fatal disease known as pulmonary embolism. Application of high-power ultrasound has been successful in studies to mechanically fragment the clots. Single-element ultrasound transducers were used in most of the studies. Challenges associated with phased arrays, such as high electrical impedance and element breakdown at high voltages, were addressed in the previous study, and a high-power 64-element transducer module was designed and fabricated. In this study, a cylindrical array of 16 modules with the frequency of 260 kHz was modeled and constructed for DVT thrombolysis. The maximum pressure, focal size, and steering ability of the array were examined. In vitro experiments were conducted to assess the performance of the array. The simulated pressure amplitude of 34 MPa at the depth of 55 mm (average femoral vein (FV) distance from the inner surface of the thigh) was in consistent with the experiments and satisfied the purpose of this study. Moreover, the employed module distribution resulted in a focal spot dimension of 2.4×2.8×7.3 mm3 (at the 75% pressure amplitude level) that can be confined in a human FV with the average diameter of 12 mm. In vitro experiments manifested a partial and complete clot breakdown at 11.5- and 15-MPa pressure at the focus. The design and engineering of the array system was succeeded in maintaining the desired pressure and focal size even when steered. The results presented in this study suggest the potential of the designed array system for clinical applications.
Collapse
|
20
|
Contrast Ultrasound, Sonothrombolysis and Sonoperfusion in Cardiovascular Disease: Shifting to Theragnostic Clinical Trials. JACC Cardiovasc Imaging 2022; 15:345-360. [PMID: 34656483 PMCID: PMC8837667 DOI: 10.1016/j.jcmg.2021.07.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 07/23/2021] [Indexed: 02/03/2023]
Abstract
Contrast ultrasound has a variety of applications in cardiovascular medicine, both in diagnosing cardiovascular disease as well as providing prognostic information. Visualization of intravascular contrast microbubbles is based on acoustic cavitation, the characteristic oscillation that results in changes in the reflected ultrasound waves. At high power, this acoustic response generates sufficient shear that is capable of enhancing endothelium-dependent perfusion in atherothrombotic cardiovascular disease (sonoperfusion). The oscillation and collapse of microbubbles in response to ultrasound also induces microstreaming and jetting that can fragment thrombus (sonothrombolysis). Several preclinical studies have focused on identifying optimal diagnostic ultrasound settings and treatment regimens. Clinical trials have been performed in acute myocardial infarction, stroke, and peripheral arterial disease often with improved outcome. In the coming years, results of ongoing clinical trials along with innovation and improvements in sonothrombolysis and sonoperfusion will determine whether this theragnostic technique will become a valuable addition to reperfusion therapy.
Collapse
|
21
|
Hendley SA, Paul JD, Maxwell AD, Haworth KJ, Holland CK, Bader KB. Clot Degradation Under the Action of Histotripsy Bubble Activity and a Lytic Drug. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2942-2952. [PMID: 33460375 PMCID: PMC8445066 DOI: 10.1109/tuffc.2021.3052393] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Deep vein thrombosis is a major source of morbidity worldwide. For critical obstructions, catheter-directed thrombolytics are the frontline therapy to achieve vessel recanalization. Techniques that aid lytic therapy are under development to improve treatment efficacy and reduce procedure-related complications. Histotripsy is one such adjuvant under development that relies on focused ultrasound for in situ nucleation of bubble clouds. Prior studies have demonstrated synergistic effects for clot dissolution when histotripsy is combined with lytic therapy. The success of this combination approach is hypothesized to promote thrombolytic efficacy via two mechanisms: erythrocyte fractionation (hemolysis) and increased lytic activity (fibrinolysis). In this study, the contributions of hemolysis and fibrinolysis to clot degradation under histotripsy and a lytic were quantified with measurements of hemoglobin and D-dimer, respectively. A linear regression analysis was used to determine the relationship between hemoglobin, D-dimer, and the overall treatment efficacy (clot mass loss). A similar analysis was conducted to gauge the role of bubble activity, which was assessed with passive cavitation imaging, on hemolysis and fibrinolysis. Tabulation of these data demonstrated hemolysis and fibrinolysis contributed equally to clot mass loss. Furthermore, bubble cloud activity promoted the generation of hemoglobin and D-dimer in equal proportion. These studies indicate a multifactorial process for clot degradation under the action of histotripsy and a lytic therapy.
Collapse
|
22
|
Vasiukhina A, Eshraghi J, Ahmadzadegan A, Goergen CJ, Vlachos PP, Solorio L. Stable Thermally-Modulated Nanodroplet Ultrasound Contrast Agents. NANOMATERIALS 2021; 11:nano11092225. [PMID: 34578541 PMCID: PMC8469504 DOI: 10.3390/nano11092225] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 08/22/2021] [Accepted: 08/25/2021] [Indexed: 11/16/2022]
Abstract
Liquid perfluorocarbon-based nanodroplets are stable enough to be used in extravascular imaging, but provide limited contrast enhancement due to their small size, incompressible core, and small acoustic impedance mismatch with biological fluids. Here we show a novel approach to overcoming this limitation by using a heating-cooling cycle, which we will refer to as thermal modulation (TM), to induce echogenicity of otherwise stable but poorly echogenic nanodroplets without triggering a transient phase shift. We apply thermal modulation to high-boiling point tetradecafluorohexane (TDFH) nanodroplets stabilized with a bovine serum albumin (BSA) shell. BSA-TDFH nanodroplets with an average diameter under 300 nanometers showed an 11.9 ± 5.4 mean fold increase in echogenicity on the B-mode and a 13.9 ± 6.9 increase on the nonlinear contrast (NLC) mode after thermal modulation. Once activated, the particles maintained their enhanced echogenicity (p < 0.001) for at least 13 h while retaining their nanoscale size. Our data indicate that thermally modulated nanodroplets can potentially serve as theranostic agents or sensors for various applications of contrast-enhanced ultrasound.
Collapse
Affiliation(s)
- Anastasiia Vasiukhina
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA; (A.V.); (C.J.G.)
| | - Javad Eshraghi
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA; (J.E.); (A.A.)
| | - Adib Ahmadzadegan
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA; (J.E.); (A.A.)
| | - Craig J. Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA; (A.V.); (C.J.G.)
- Center for Cancer Research, Purdue University, West Lafayette, IN 47907, USA
| | - Pavlos P. Vlachos
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA; (J.E.); (A.A.)
- Correspondence: (P.P.V.); (L.S.)
| | - Luis Solorio
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA; (A.V.); (C.J.G.)
- Center for Cancer Research, Purdue University, West Lafayette, IN 47907, USA
- Correspondence: (P.P.V.); (L.S.)
| |
Collapse
|
23
|
Singh R, Jo J, Riegel M, Forrest ML, Yang X. The feasibility of ultrasound-assisted endovascular laser thrombolysis in an acute rabbit thrombosis model. Med Phys 2021; 48:4128-4138. [PMID: 34214203 DOI: 10.1002/mp.15068] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/27/2021] [Accepted: 06/21/2021] [Indexed: 12/31/2022] Open
Abstract
PURPOSE This study aimed to test the feasibility of combined ultrasound and laser technique, namely, ultrasound-assisted endovascular laser thrombolysis (USELT), for thrombolysis by conducting in vivo tests in a rabbit thrombosis model. MATERIALS AND METHODS An acute thrombus was created in the right jugular vein of rabbit and then was treated with ultrasound only, laser only, and USELT to dissolve the blood clot. A total of 20 rabbits were used. Out of which, the first three rabbits were used to titrate the laser and ultrasound parameters. Then, five rabbits were treated with ultrasound only, five rabbits were treated with laser only, and seven rabbits were treated with USELT. During USELT, 532-nm laser pulses were delivered endovascularly directly to the clot through a fiber optic, and 0.5 MHz ultrasound pulses were applied noninvasively to the same region. A laser fluence of 4 to 12 mJ/cm2 and ultrasound amplitude of 1 to 2 MPa were used. Recanalization of the jugular vein was assessed by performing ultrasound Doppler imaging immediately after the treatment. The maximum blood flow speed after the treatment as compared to its value before the treatment was used to calculate the blood flow recovery in vessel. RESULTS The blood flow was fully recovered (100%) in three rabbits, partially recovered in two rabbits (more than 50% and less than 100%) with mean percentage recovery of 69.73% and poorly recovered in two rabbits (<50%) with mean percentage recovery of 6.2% in the USELT group. In contrast, the treatment group with ultrasound or laser alone did not show recanalization of vein in any case, all the five rabbits were poorly/not recovered with a mean percentage recovery of 0%. CONCLUSIONS The USELT technology was shown to effectively dissolve the blood clots in an acute rabbit jugular vein thrombosis model.
Collapse
Affiliation(s)
- Rohit Singh
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Janggun Jo
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.,Vesarex LLC, Lawrence, Kansas, USA
| | - Matthew Riegel
- Animal Care Unit, University of Kansas, Lawrence, Kansas, USA
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, Kansas, 66045, USA
| | - Xinmai Yang
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| |
Collapse
|
24
|
Efficacy Estimation of Microbubble-Assisted Local Sonothrombolysis Using a Catheter with a Series of Miniature Transducers. MICROMACHINES 2021; 12:mi12060612. [PMID: 34073428 PMCID: PMC8228781 DOI: 10.3390/mi12060612] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/17/2021] [Accepted: 05/21/2021] [Indexed: 11/30/2022]
Abstract
Intravascular ultrasound has good prospects for clinical applications in sonothrombolysis. The catheter-based side-looking intravascular ultrasound thrombolysis (e.g., Ekosonic catheters) used in clinical studies has a high frequency (2 MHz). The lower-frequency ultrasound requires a larger-diameter transducer. In our study, we designed and manufactured a small ultrasound-based prototype catheter that can emit a lower frequency ultrasound (1.1 MHz). In order to evaluate the safety and efficacy of local low-frequency ultrasound-enhanced thrombolysis, a microbubble (MB) was introduced to augment thrombolysis effect of locally delivered low-intensity ultrasound. The results demonstrated that combination of ultrasound and MB realized higher clot lysis than urokinase-only treatment (17.0% ± 1.2% vs. 14.9% ± 2.7%) under optimal ultrasound settings of 1.1 MHz, 0.414 MPa, 4.89 W/cm2, 5% duty cycle and MB concentration of 60 μg/mL. When urokinase was added, the fibrinolysis accelerated by MB and ultrasound resulted in a further increased thrombolysis rate that was more than two times than that of urokinase alone (36.7% ± 5.5% vs. 14.9% ± 2.7%). However, a great quantity of ultrasound energy was required to achieve substantial clot lysis without MB, leading to the situation that temperature accumulated inside the clot became harmful. We suggest that MB-assisted local sonothrombolysis be considered as adjuvant therapy of thrombolytic agents.
Collapse
|
25
|
Deprez J, Lajoinie G, Engelen Y, De Smedt SC, Lentacker I. Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery. Adv Drug Deliv Rev 2021; 172:9-36. [PMID: 33705877 DOI: 10.1016/j.addr.2021.02.015] [Citation(s) in RCA: 101] [Impact Index Per Article: 33.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 02/01/2021] [Accepted: 02/17/2021] [Indexed: 12/13/2022]
Abstract
Apart from its clinical use in imaging, ultrasound has been thoroughly investigated as a tool to enhance drug delivery in a wide variety of applications. Therapeutic ultrasound, as such or combined with cavitating nuclei or microbubbles, has been explored to cross or permeabilize different biological barriers. This ability to access otherwise impermeable tissues in the body makes the combination of ultrasound and therapeutics very appealing to enhance drug delivery in situ. This review gives an overview of the most important biological barriers that can be tackled using ultrasound and aims to provide insight on how ultrasound has shown to improve accessibility as well as the biggest hurdles. In addition, we discuss the clinical applicability of therapeutic ultrasound with respect to the main challenges that must be addressed to enable the further progression of therapeutic ultrasound towards an effective, safe and easy-to-use treatment tailored for drug delivery in patients.
Collapse
Affiliation(s)
- J Deprez
- Ghent Research Group on Nanomedicines, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| | - G Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, P.O. Box 217, 7500 AE Enschede, Netherlands
| | - Y Engelen
- Ghent Research Group on Nanomedicines, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| | - S C De Smedt
- Ghent Research Group on Nanomedicines, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium.
| | - I Lentacker
- Ghent Research Group on Nanomedicines, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| |
Collapse
|
26
|
Bader KB, Hendley SA, Bollen V. Assessment of Collaborative Robot (Cobot)-Assisted Histotripsy for Venous Clot Ablation. IEEE Trans Biomed Eng 2021; 68:1220-1228. [PMID: 32915723 PMCID: PMC8018710 DOI: 10.1109/tbme.2020.3023630] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The application of bubble-based ablation with the focus ultrasound therapy histotripsy is gaining traction for the treatment of venous thrombosis, among other pathologies. For extensive clot burden, the histotripsy source must be translated to ensure uniform bubble activity throughout the vascular obstruction. The purpose of this study was to evaluate the targeting accuracy of a histotripsy system comprised of a focused source, ultrasound image guidance, and a collaborative robot (cobot) positioner. The system was designed with a primary emphasis for treating deep vein thrombosis. METHODS Studies to test treatment planning and targeting bubble activity with the histotripsy-cobot system were conducted in an in vitro clot model. A tissue-mimicking phantom was also targeted with the system, and the predicted and actual areas of liquefaction were compared to gauge the spatial accuracy of ablation. RESULTS The system provided submillimeter accuracy for both tracking along an intended path (within 0.6 mm of a model vessel) and targeting bubble activity within the venous clot model (0.7 mm from the center of the clot). Good correlation was observed between the planned and actual liquefaction locations in the tissue phantom, with an average Dice similarity coefficient of 77.8%, and average Hausdorff distance of 1.6 mm. CONCLUSION Cobots provide an effective means to apply histotripsy pulses over a treatment volume, with the ablation precision contingent on the quality of image guidance. SIGNIFICANCE Overall, these results demonstrate cobots can be used to guide histotripsy ablation for targets that extend beyond the natural focus of the transducer.
Collapse
|
27
|
Lafond M, Salido NG, Haworth KJ, Hannah AS, Macke GP, Genstler C, Holland CK. Cavitation Emissions Nucleated by Definity Infused through an EkoSonic Catheter in a Flow Phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:693-709. [PMID: 33349516 PMCID: PMC11537209 DOI: 10.1016/j.ultrasmedbio.2020.10.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/05/2020] [Accepted: 10/18/2020] [Indexed: 06/12/2023]
Abstract
The EkoSonic endovascular system has been cleared by the U.S. Food and Drug Administration for the controlled and selective infusion of physician specified fluids, including thrombolytics, into the peripheral vasculature and the pulmonary arteries. The objective of this study was to explore whether this catheter technology could sustain cavitation nucleated by infused Definity, to support subsequent studies of ultrasound-mediated drug delivery to diseased arteries. The concentration and attenuation spectroscopy of Definity were assayed before and after infusion at 0.3, 2.0 and 4.0 mL/min through the EkoSonic catheter. PCI was used to map and quantify stable and inertial cavitation as a function of Definity concentration in a flow phantom mimicking the porcine femoral artery. The 2.0 mL/min infusion rate yielded the highest surviving Definity concentration and acoustic attenuation. Cavitation was sustained throughout each 15 ms ultrasound pulse, as well as throughout the 3 min infusion. These results demonstrate a potential pathway to use cavitation nucleation to promote drug delivery with the EkoSonic endovascular system.
Collapse
Affiliation(s)
- Maxime Lafond
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA.
| | - Nuria G Salido
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA
| | - Kevin J Haworth
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Gregory P Macke
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA
| | | | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| |
Collapse
|
28
|
Das D, Sivasubramanian K, Rajendran P, Pramanik M. Label-free high frame rate imaging of circulating blood clots using a dual modal ultrasound and photoacoustic system. JOURNAL OF BIOPHOTONICS 2021; 14:e202000371. [PMID: 33231356 DOI: 10.1002/jbio.202000371] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/01/2020] [Accepted: 11/23/2020] [Indexed: 05/06/2023]
Abstract
Deep vein thrombosis (DVT) is a disorder when a blood clot (thrombus) is formed in one of the deep veins. These clots detach from the original sites and circulate in the blood stream at high velocities. Diagnosing these blood clots at an early stage is necessary to decide the treatment strategy. For label-free, in vivo, and real-time detection, high framerate photoacoustic imaging can be used. In this work, a dual modal clinical ultrasound and photoacoustic (PA) system is used for the high framerate PA imaging of circulating blood clots in blood at linear velocities up to 107 cm/sec. Blood clot had 1.4 times higher signal-to-noise ratio (SNR) in the static mode and 1.3 times higher SNR compared to blood PA signal in the flow experiments. This work demonstrates that fast-moving circulating blood clots are easy to recognize against the background PA signal and may aid in early diagnosis.
Collapse
Affiliation(s)
- Dhiman Das
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
| | | | | | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
| |
Collapse
|
29
|
Kleven RT, Karani KB, Hilvert N, Ford SM, Mercado-Shekhar KP, Racadio JM, Rao MB, Abruzzo TA, Holland CK. Accelerated sonothrombolysis with Definity in a xenographic porcine cerebral thromboembolism model. Sci Rep 2021; 11:3987. [PMID: 33597659 PMCID: PMC7889614 DOI: 10.1038/s41598-021-83442-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Accepted: 01/29/2021] [Indexed: 01/31/2023] Open
Abstract
Adjuvant ultrasound at 2 MHz with or without an ultrasound contrast agent improves the rate of thrombus resolution by recombinant tissue plasminogen activator (rt-PA) in laboratory and clinical studies. A sub-megahertz approach can further expand this therapy to a subset of patients with an insufficient temporal bone window, improving efficacy in unselected patient populations. The aim of this study was to determine if a clinical ultrasound contrast agent (UCA), Definity, and 220 kHz pulsed ultrasound accelerated rt-PA thrombolysis in a preclinical animal model of vascular occlusion. The effect of Definity and ultrasound on thrombus clearance was first investigated in vitro and subsequently tested in a xenographic porcine cerebral thromboembolism model in vivo. Two different microcatheter designs (end-hole, multi-side-hole) were used to infuse rt-PA and Definity at the proximal edge or directly into clots, respectively. Sonothrombolysis with Definity increased clot mass loss relative to saline or rt-PA alone in vitro, only when rt-PA was administered directly into clots via a multi-side-hole microcatheter. Combined treatment with rt-PA, Definity, and ultrasound in vivo increased the rate of reperfusion up to 45 min faster than clots treated with rt-PA or saline. In this porcine cerebral thromboembolism model employing retracted human clots, 220 kHz ultrasound, in conjunction with Definity increased the probability of early successful reperfusion with rt-PA.
Collapse
Affiliation(s)
- Robert T Kleven
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, CVC 3921, 0586, 231 Albert Sabin Way, Cincinnati, OH, 45267-0586, USA.
| | - Kunal B Karani
- Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Nicole Hilvert
- Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Samantha M Ford
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Karla P Mercado-Shekhar
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - John M Racadio
- Department of Radiology and Medical Imaging, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Marepalli B Rao
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, CVC 3921, 0586, 231 Albert Sabin Way, Cincinnati, OH, 45267-0586, USA
| | - Todd A Abruzzo
- Division of Radiology, Phoenix Children's Hospital, Phoenix, AZ, USA
- Department of Radiology, University of Arizona College of Medicine, Phoenix, AZ, USA
| | - Christy K Holland
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, CVC 3921, 0586, 231 Albert Sabin Way, Cincinnati, OH, 45267-0586, USA
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
30
|
Hinds MT, Ammi AY, Johnson J, Kaul S. Quantification of microbubble-induced sonothrombolysis in an ex vivo non-human primate model. J Thromb Haemost 2021; 19:502-512. [PMID: 33205492 PMCID: PMC8591990 DOI: 10.1111/jth.15180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 11/09/2020] [Accepted: 11/11/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND In vitro studies with ultrasound (US) and microbubbles (MB) have reported that sono-thrombolysis can be achieved at high peak rarefactional acoustic pressure amplitudes (PRAPAs) using 0.25 and 1.05 MHz US frequencies. OBJECTIVE The aim of the current study was to determine if these parameters work on an ex vivo physiological model of thrombosis. METHODS A thrombogenic device was placed in an ex vivo chronic arteriovenous shunt in juvenile baboons. Platelet accumulation was measured by dynamic imaging of the device and the 10 cm thrombus tail with 111 In-labeled platelets. After 15 minutes of thrombus formation, treatment with either low-dose recombinant tissue plasminogen activator (rtPA) or low-dose rtPA + MB+US was performed for 20 minutes. Four US settings at 0.25% duty cycle were used: 0.25 MHz at PRAPAs of 1.20 and 2.20 MPa, and 1.05 MHz at 1.75 and 4.75 MPa. RESULTS Platelet accumulation was not inhibited by low-dose rtPA or MB with US alone. Platelet accumulation was significantly reduced with 0.25 MHz US at 2.20 PRAPA (P < .001) and with 1.05 MHz at 1.75 MPa and 4.75 MPa (P < .05) when used with MB and low-dose rtPA. Although this approach prevented platelet accumulation it did not cause thrombolysis on the device. CONCLUSIONS rtPA + MB + US (0.25 and 1.05 MHz) resulted in inhibition of platelet accumulation on the thrombogenic device when moderately high PRAPAs (≥1.75 MPa) were used. These results taken in context with lytic effects of US on myocardial microthrombi and direct effect on myocardial blood flow and function provide direction for the use of therapeutic US in acute coronary syndromes.
Collapse
Affiliation(s)
- Monica T. Hinds
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Azzdine Y. Ammi
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Jennifer Johnson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Sanjiv Kaul
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
31
|
Jo J, Forrest ML, Yang X. Ultrasound-assisted laser thrombolysis with endovascular laser and high-intensity focused ultrasound. Med Phys 2020; 48:579-586. [PMID: 33280145 DOI: 10.1002/mp.14636] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/15/2020] [Accepted: 11/29/2020] [Indexed: 12/20/2022] Open
Abstract
PURPOSE The combination of laser and ultrasound can significantly improve the efficiency of thrombolysis through an enhanced cavitation effect. We developed a fiber optics-based laser-ultrasound thrombolysis device and tested the feasibility and efficiency of this technology for restoring blood flow in an in vitro blood clot model. METHODS An in vitro blood flow-clot model was setup, and then an endovascular laser thrombolysis system was combined with high-intensity focused ultrasound to remove the clot. The laser and ultrasound pulses were synchronized and delivered to the blood clot concurrently. The laser pulses of 532 nm were delivered to the blood clot endovascularly through an optical fiber, whereas the ultrasound pulses of 0.5 MHz were applied noninvasively to the same region. Effectiveness of thrombolysis was evaluated by the ability to restore blood flow, which was monitored by ultrasound Doppler. RESULTS As laser powers increased, the ultrasound threshold pressures for effective thrombolysis decreased. For laser fluence levels of 0, 2, and 4 mJ/cm2 , the average negative ultrasound threshold pressures were 1.26 ± 0.114, 1.05 ± 0.181, and 0.59 ± 0.074 MPa, respectively. The periods of time needed to achieve effective thrombolysis were measured at 0.8, 2, and 4 mJ/cm2 laser fluence levels and 0.42, 0.70, and 0.98 MPa negative ultrasound pressures. In general, thrombolysis could be achieved more rapidly with higher laser powers or ultrasound pressures. CONCLUSIONS Effective thrombolysis can be achieved by combining endovascular laser with noninvasive ultrasound at relatively low power and pressure levels, which can potentially improve both the treatment efficiency and safety.
Collapse
Affiliation(s)
- Janggun Jo
- Vesarex LLC, Lawrence, KS, 66047, USA.,Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, 48109, USA
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, the University of Kansas, Lawrence, Kansas, 66045, USA
| | - Xinmai Yang
- Institute for Bioengineering Research and Department of Mechanical Engineering, the University of Kansas, Lawrence, Kansas, 66045, USA
| |
Collapse
|
32
|
Kim J, DeRuiter RM, Goel L, Xu Z, Jiang X, Dayton PA. A Comparison of Sonothrombolysis in Aged Clots between Low-Boiling-Point Phase-Change Nanodroplets and Microbubbles of the Same Composition. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3059-3068. [PMID: 32800631 PMCID: PMC8146824 DOI: 10.1016/j.ultrasmedbio.2020.07.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 04/08/2020] [Accepted: 07/02/2020] [Indexed: 05/06/2023]
Abstract
We present enhanced cavitation erosion of blood clots exposed to low-boiling-point (-2°C) perfluorocarbon phase-change nanodroplets and pulsed ultrasound, as well as microbubbles with the same formulation under the same conditions. Given prior success with microbubbles as a sonothrombolysis agent, we considered that perfluorocarbon phase-change nanodroplets could enhance clot disruption further beyond that achieved with microbubbles. It has been hypothesized that owing to their small size and ability to penetrate into a clot, nanodroplets could enhance cavitation inside a blood clot and increase sonothrombolysis efficacy. The thrombolytic effects of lipid-shell-decafluorobutane nanodroplets were evaluated and compared with those of microbubbles with the same formulation, in an aged bovine blood clot flow model. Seven different pulsing schemes, with an acoustic intensity (ISPTA) range of 0.021-34.8 W/cm2 were applied in three different therapy scenarios: ultrasound only, ultrasound with microbubbles and ultrasound with nanodroplets (n = 5). Data indicated that pulsing schemes with 0.35 W/cm2 and 5.22 W/cm2 produced a significant difference (p < 0.05) in nanodroplet sonothrombolysis performance compared with compositionally identical microbubbles. With these excitation conditions, nanodroplet-mediated treatment achieved a 140% average thrombolysis rate over the microbubble-mediated case. We observed distinctive internal erosion in the middle of bovine clot samples from nanodroplet-mediated ultrasound, whereas the microbubble-mediated case generated surface erosion. This erosion pattern was supported by ultrasound imaging during sonothrombolysis, which revealed that nanodroplets generated cavitation clouds throughout a clot, whereas microbubble cavitation formed larger cavitation clouds only outside a clot sample.
Collapse
Affiliation(s)
- Jinwook Kim
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Ryan M DeRuiter
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Leela Goel
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Xiaoning Jiang
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA.
| |
Collapse
|
33
|
Zhang Z, Su M, Li F, Liu R, Cai R, Li G, Jiang Q, Zhong H, Shrout TR, Zhang S, Zheng H, Qiu W. New Sm-PMN-PT Ceramic-Based 2-D Array for Low-Intensity Ultrasound Therapy Application. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:2085-2094. [PMID: 32149634 DOI: 10.1109/tuffc.2020.2979471] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
A two-dimensional (2-D) array with a small pitch (approximately 0.5λ in medium) can achieve complete 3-D control of ultrasound beams without grating lobes and enable the generation of multiple focal spots simultaneously, which is a desired tool for noninvasive therapy. However, the large electrical impedance of 2-D array elements owing to their small size results in a low energy transfer efficiency between a 2-D array and an electrical system, thereby limiting their practical applications. This article presents the development of a 1-MHz 256-element 2-D array ultrasonic transducer of low electrical impedance based on a new Sm-doped Pb(Mg1/3Nb2/3)O3-PbTiO3 (Sm-PMN-PT) piezoceramic with ultrahigh dielectric permittivity. The electrical impedance of the array element is decreased by 3.4 times as the Sm-PMN-PT replacing commercial PZT-5H. Consequently, the output acoustic pressure of the 2-D array made of Sm-PMN-PT ceramic is approximately twice that of the 2-D array made of PZT-5H ceramic under the same excitation conditions. Array elements are spaced at a 1.1-mm pitch ( 0.71λ in water), enabling a large steering range of the ultrasound beam. A multiple-target blood-brain barrier opening in vivo is demonstrated using the proposed 2-D array with electronic focusing and steering. The obtained results indicate that the 2-D array made of Sm-PMN-PT ceramic is promising for practical use in low-intensity ultrasound therapy applications.
Collapse
|
34
|
Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN. Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2861-2870. [PMID: 32732167 DOI: 10.1016/j.ultrasmedbio.2020.06.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 06/24/2020] [Accepted: 06/27/2020] [Indexed: 06/11/2023]
Abstract
Submicron phase-change droplets are an emerging class of ultrasound contrast agent. Compared with microbubbles, their relatively small size and increased stability offer the potential to passively extravasate and accumulate in solid tumors through the enhanced permeability and retention effect. Under exposure to sufficiently powerful ultrasound, these droplets can convert into in situ gas microbubbles and thus be used as an extravascular-specific contrast agent. However, in vivo imaging methods to detect extravasated droplets have yet to be established. Here, we develop an ultrasound imaging pulse sequence within diagnostic safety limits to selectively detect droplet extravasation in tumors. Tumor-bearing mice were injected with submicron perfluorobutane droplets and interrogated with our imaging-vaporization-imaging sequence. By use of a pulse subtraction method, median droplet extravasation signal relative to the total signal within the tumor was estimated to be Etumor=37±5% compared with the kidney Ekidney=-2±8% (p < 0.001). This work contributes toward the advancement of volatile phase-shift droplets as a next-generation ultrasound agent for imaging and therapy.
Collapse
Affiliation(s)
- Brandon L Helfield
- Department of Physics, Concordia University, Montreal, Canada; Department of Biology, Concordia University, Montreal, Canada.
| | - Kimoon Yoo
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Jingjing Liu
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Ross Williams
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Paul S Sheeran
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - David E Goertz
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Peter N Burns
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
35
|
Muller MA, Xie A, Qi Y, Zhao Y, Ozawa K, Noble-Vranish M, Lindner JR. Regional and Conducted Vascular Effects of Endovascular Ultrasound Catheters. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2361-2369. [PMID: 32522456 PMCID: PMC7720779 DOI: 10.1016/j.ultrasmedbio.2020.05.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 05/06/2020] [Accepted: 05/10/2020] [Indexed: 06/03/2023]
Abstract
Intra-vascular ultrasound catheters are used clinically to facilitate clot lysis. We hypothesized that these devices could also directly lower microvascular resistance and increase tissue perfusion through established shear-dependent pathways. In mice, either the proximal hind-limb muscles or the upstream femoral artery alone was exposed to an endovascular ultrasound catheter (2.3 MHz, 0.5-1.1 MPa) for 10 min. Quantitative microvascular perfusion imaging in the hind limbs exposed to the endovascular ultrasound system exhibited a more-than-twofold increase in flow (p < 0.01) compared with the contralateral control limb after exposure of either the muscle or the femoral artery alone. Using an in vivo optical imaging reporting system, an eight- to ninefold increase in tissue adenosine triphosphate (ATP) was detected in the region of insonification (p = 0.006). Ultrasound was found to produce an immediate release of ATP from ex vivo erythrocytes (p = 0.03). In situ electrochemical sensing revealed an immediate increase in nitric oxide with initiation of ultrasound which returned to baseline within 5 min of termination, as well as ultrasound-triggered nitric oxide (NO) release from erythrocytes. These data indicate that non-cavitating ultrasound produced by endovascular catheters can reduce vascular resistance and increase flow through recognized shear-dependent vasodilator pathways involving purinergic signaling and NO.
Collapse
Affiliation(s)
- Matthew A Muller
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Aris Xie
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Yue Qi
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Yan Zhao
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Koya Ozawa
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | | | - Jonathan R Lindner
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA; Oregon National Primate Research Center, Oregon Health & Science University, Portland, Oregon, USA.
| |
Collapse
|
36
|
Guan L, Wang C, Yan X, Liu L, Li Y, Mu Y. A thrombolytic therapy using diagnostic ultrasound combined with RGDS-targeted microbubbles and urokinase in a rabbit model. Sci Rep 2020; 10:12511. [PMID: 32719362 PMCID: PMC7385658 DOI: 10.1038/s41598-020-69202-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 04/10/2020] [Indexed: 11/22/2022] Open
Abstract
This study aimed to explore thrombolysis therapy based on ultrasound combined with urokinase and Arg–Gly–Asp sequence (RGDS)-targeted microbubbles by evaluating the histological changes in a thrombotic rabbit model. Forty-two New Zealand rabbits featuring platelet-rich thrombi in the femoral artery were randomized to (n = 6/group): ultrasound alone (US); urokinase alone (UK); ultrasound plus non-targeted microbubbles (US + M); ultrasound plus RGDS-targeted microbubbles (US + R); RGDS-targeted microbubbles plus urokinase (R + UK); ultrasound, non-targeted microbubbles and urokinase (US + M + UK); and ultrasound, RGDS-targeted microbubbles and urokinase (US + R + UK) groups. Diagnostic ultrasound was used transcutaneously over the thrombus for 30 min. We evaluated the thrombolytic effect based on ultrasound thrombi detection, blood flow, and histological observations. Among all study groups, complete recanalization was achieved in the US + R + UK group. Hematoxylin and eosin staining showed that the thrombi were completely dissolved. Scanning electron microscopy examination demonstrated that the fiber network structure of the thrombi was damaged. Transmission electron microscopy showed that the thrombus was decomposed into high electron-dense particles. Histology for von Willebrand factor and tissue factor were both negative in the US + R + UK group. This study revealed that a thrombolytic therapy consisting of diagnostic ultrasound together with RGDS-targeted and urokinase coupled microbubbles.
Collapse
Affiliation(s)
- Lina Guan
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China
| | - Chunmei Wang
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China
| | - Xue Yan
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China
| | - Liyun Liu
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China
| | - Yanhong Li
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China
| | - Yuming Mu
- Department of Echocardiography, First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People's Republic of China.
| |
Collapse
|
37
|
Ma L, Wang Y, Zhang S, Qian X, Xue N, Jiang Z, Akakuru OU, Li J, Xu Y, Wu A. Deep Penetration of Targeted Nanobubbles Enhanced Cavitation Effect on Thrombolytic Capacity. Bioconjug Chem 2019; 31:369-374. [DOI: 10.1021/acs.bioconjchem.9b00653] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Ling Ma
- Department of Ultrasound, Ningbo First Hospital, Ningbo 315010, China
| | - Yinjie Wang
- Cixi Institute of Biomedical Engineering, CAS Key Laboratory of Magnetic Materials and Devices, Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Shengmin Zhang
- Department of Ultrasound, Ningbo First Hospital, Ningbo 315010, China
| | - Xuechen Qian
- Department of Ultrasound, Ningbo First Hospital, Ningbo 315010, China
- Medical School of Ningbo University, Ningbo 315211, China
| | - Nianyu Xue
- Department of Ultrasound, Ningbo First Hospital, Ningbo 315010, China
| | - Zhenqi Jiang
- Cixi Institute of Biomedical Engineering, CAS Key Laboratory of Magnetic Materials and Devices, Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ozioma Udochukwu Akakuru
- Cixi Institute of Biomedical Engineering, CAS Key Laboratory of Magnetic Materials and Devices, Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Juan Li
- Cixi Institute of Biomedical Engineering, CAS Key Laboratory of Magnetic Materials and Devices, Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
| | - Youfeng Xu
- Department of Ultrasound, Ningbo First Hospital, Ningbo 315010, China
| | - Aiguo Wu
- Cixi Institute of Biomedical Engineering, CAS Key Laboratory of Magnetic Materials and Devices, Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
| |
Collapse
|
38
|
Zhang B, Kim H, Wu H, Gao Y, Jiang X. Sonothrombolysis with magnetic microbubbles under a rotational magnetic field. ULTRASONICS 2019; 98:62-71. [PMID: 31202970 PMCID: PMC6710138 DOI: 10.1016/j.ultras.2019.06.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 03/28/2019] [Accepted: 06/09/2019] [Indexed: 05/06/2023]
Abstract
Thrombosis is an extremely critical clinical condition where a clot forms inside a blood vessel which blocks the blood flow through the cardiovascular system. Previous sonothrombolysis methods using ultrasound and microbubbles (MBs) often have a relatively low lysis rate due to the low microbubbles concentration at clot region caused by blood flow in the vessel. To solve this problem, the magnetic microbubbles (MMBs) that can be retained by an outer magnetic field against blood flow are used in this study. Here we report the development of a new method using the rotational magnetic field to trap and vibrate magnetic microbubbles at target clot region and then using an intravascular forward-looking ultrasound transducer to activate them acoustically. In this study, we investigated the influence of different blood flow conditions, vessel occlusion conditions (partial and fully occluded), clot ages (fresh, retracted), ultrasound parameters (input voltage, duty cycle) and rotational magnetic field parameters (amplitude, frequency) on the thrombolysis rate. The results showed that the additional use of magnetic microbubbles significantly enhances in vitro lysis of blood clot.
Collapse
Affiliation(s)
- Bohua Zhang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
| | - Howuk Kim
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
| | - Huaiyu Wu
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
| | - Yu Gao
- Institute of Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210023, China
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA.
| |
Collapse
|
39
|
Kleven RT, Karani KB, Salido NG, Shekhar H, Haworth KJ, Mast TD, Tadesse DG, Holland CK. The effect of 220 kHz insonation scheme on rt-PA thrombolytic efficacy in vitro. Phys Med Biol 2019; 64:165015. [PMID: 31189149 DOI: 10.1088/1361-6560/ab293b] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Ultrasound-enhanced recombinant tissue plasminogen activator (rt-PA) thrombolysis is under development as an adjuvant to ischemic stroke therapy. The goal of this study was to design a pulsed ultrasound (US) exposure scheme that reduced intracranial constructive interference and tissue heating, and maintained thrombolytic efficacy relative to continuous wave (CW) insonation. Three 220 kHz US schemes were evaluated, two pulsed insonation schemes (15 cycles, 68 µs pulse duration, 33% or 62.5% duty cycle) and an intermittent CW insonation scheme (50 s active, 30 s quiescent) over a 30-min treatment period. An in silico study using a finite-difference model of transcranial US propagation was performed to estimate the intracranial acoustic field and temperature rise in the skull for each insonation scheme. In vitro measurements with flow were performed to assess thrombolysis using time-lapse microscopy. Intracranial constructive interference was not reduced with pulsed US using a pulse length of 15 cycles compared to intermittent CW US. The 33.3% duty cycle pulsed US scheme reduced heating in the temporal bone as much as 60% relative to the intermittent CW scheme. All insonation schemes promoted sustained stable cavitation in vitro and augmented thrombolysis compared to rt-PA alone (p < 0.05). Ultraharmonic (UH) and harmonic cumulative energy over a 30 min treatment period was significantly higher (p < 0.05) for the intermittent CW US scheme compared to either pulsed US scheme. Despite the difference in cavitation emissions, no difference was observed in the clot lysis between the three US schemes. These findings demonstrate that a 33.3% duty cycle pulsed US scheme with a 15-cycle burst can reduce bone heating and achieve equivalent thrombolytic efficacy as an intermittent CW scheme.
Collapse
Affiliation(s)
- Robert T Kleven
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States of America. Robert Kleven, CVC 3921, 0586, 231 Albert Sabin Way, Cincinnati, OH 45267-0586, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Shekhar H, Kleven RT, Peng T, Palaniappan A, Karani KB, Huang S, McPherson DD, Holland CK. In vitro characterization of sonothrombolysis and echocontrast agents to treat ischemic stroke. Sci Rep 2019; 9:9902. [PMID: 31289285 PMCID: PMC6616381 DOI: 10.1038/s41598-019-46112-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 06/12/2019] [Indexed: 12/30/2022] Open
Abstract
The development of adjuvant techniques to improve thrombolytic efficacy is important for advancing ischemic stroke therapy. We characterized octafluoropropane and recombinant tissue plasminogen activator (rt-PA)-loaded echogenic liposomes (OFP t-ELIP) using differential interference and fluorescence microscopy, attenuation spectroscopy, and electrozone sensing. The loading of rt-PA in OFP t-ELIP was assessed using spectrophotometry. Further, it was tested whether the agent shields rt-PA against degradation by plasminogen activator inhibitor-1 (PAI-1). An in vitro system was used to assess whether ultrasound (US) combined with either Definity or OFP t-ELIP enhances rt-PA thrombolysis. Human whole blood clots were mounted in a flow system and visualized using an inverted microscope. The perfusate consisted of either (1) plasma alone, (2) rt-PA, (3) OFP t-ELIP, (4) rt-PA and US, (5) OFP t-ELIP and US, (6) Definity and US, or (7) rt-PA, Definity, and US (n = 16 clots per group). An intermittent US insonation scheme was employed (220 kHz frequency, and 0.44 MPa peak-to-peak pressures) for 30 min. Microscopic imaging revealed that OFP t-ELIP included a variety of structures such as liposomes (with and without gas) and lipid-shelled microbubbles. OFP t-ELIP preserved up to 76% of rt-PA activity in the presence of PAI-1, whereas only 24% activity was preserved for unencapsulated rt-PA. The use of US with rt-PA and Definity enhanced lytic efficacy (p < 0.05) relative to rt-PA alone. US combined with OFP t-ELIP enhanced lysis over OFP t-ELIP alone (p < 0.01). These results demonstrate that ultrasound combined with Definity or OFP t-ELIP can enhance the lytic activity relative to rt-PA or OFP t-ELIP alone, respectively.
Collapse
Affiliation(s)
- Himanshu Shekhar
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA.
| | - Robert T Kleven
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Tao Peng
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - Arunkumar Palaniappan
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Kunal B Karani
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA
| | - Shaoling Huang
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - David D McPherson
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH, USA.,Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
41
|
Acconcia CN, Leung BYC, Winch G, Wang J, Hynynen K, Goertz DE. Acoustic radiation force induced accumulation and dynamics of microbubbles on compliant surfaces. Phys Med Biol 2019; 64:135003. [PMID: 31082815 DOI: 10.1088/1361-6560/ab2163] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Ultrasound stimulated microbubbles have been shown to be capable of breaking up blood clots through micro-scale interactions occurring near the clot surface. However, only a small fraction of bubbles circulating in the bloodstream will be in close proximity to such boundaries, where they must be to elicit therapeutic effects. Here, the accumulation and subsequent behavior of microbubbles displaced from an overlying flow channel to a boundary under radiation forces were examined. Experimental data were acquired using a novel high speed microscopy configuration and simulations were conducted to provide insight into the accumulation process. There was broad agreement between experiments and simulations, both indicating that the size distribution and number of bubbles arriving at the boundary depended on channel flow rate, applied pressure, and bubble concentration. For example, higher flow rates and lower pressures favored the accumulation of larger bubbles relative to the native agent distribution. Moreover, bubble dynamics were dependent on the surface type, exhibiting rapid translation along agarose gel surfaces whereas on fibrin surfaces, they accumulated in localized regions inducing repetitive strain cycles. The results indicate that the process of bringing bubbles from within a vessel to a boundary is complex and should be an important consideration in the development of therapeutic applications such as sonothrombolysis.
Collapse
Affiliation(s)
- Christopher N Acconcia
- Department of Medical Biophysics, University of Toronto, Toronto, M5S 1A1, Canada. Sunnybrook Research Institute, 2075 Bayview Avenue, M4N 3M5, Toronto, Canada. These authors contributed equally
| | | | | | | | | | | |
Collapse
|
42
|
de Saint Victor M, Barnsley LC, Carugo D, Owen J, Coussios CC, Stride E. Sonothrombolysis with Magnetically Targeted Microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1151-1163. [PMID: 30773375 DOI: 10.1016/j.ultrasmedbio.2018.12.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 12/18/2018] [Accepted: 12/22/2018] [Indexed: 05/13/2023]
Abstract
Microbubble-enhanced sonothrombolysis is a promising approach to increasing the tolerability and efficacy of current pharmacological treatments for ischemic stroke. Maintaining therapeutic concentrations of microbubbles and drugs at the clot site, however, poses a challenge. The objective of this study was to investigate the effect of magnetic microbubble targeting upon clot lysis rates in vitro. Retracted whole porcine blood clots were placed in a flow phantom of a partially occluded middle cerebral artery. The clots were treated with a combination of tissue plasminogen activator (0.75 µg/mL), magnetic microbubbles (∼107 microbubbles/mL) and ultrasound (0.5 MHz, 630-kPa peak rarefactional pressure, 0.2-Hz pulse repetition frequency, 2% duty cycle). Magnetic targeting was achieved using a single permanent magnet (0.08-0.38 T and 12-140 T/m in the region of the clot). The change in clot diameter was measured optically over the course of the experiment. Magnetic targeting produced a threefold average increase in lysis rates, and linear correlation was observed between lysis rate and total energy of acoustic emissions.
Collapse
Affiliation(s)
- Marie de Saint Victor
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Lester C Barnsley
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Dario Carugo
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Joshua Owen
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Constantin C Coussios
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom.
| |
Collapse
|
43
|
Bader KB, Vlaisavljevich E, Maxwell AD. For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1056-1080. [PMID: 30922619 PMCID: PMC6524960 DOI: 10.1016/j.ultrasmedbio.2018.10.035] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 09/28/2018] [Accepted: 10/03/2018] [Indexed: 05/04/2023]
Abstract
Histotripsy is a focused ultrasound therapy for non-invasive tissue ablation. Unlike thermally ablative forms of therapeutic ultrasound, histotripsy relies on the mechanical action of bubble clouds for tissue destruction. Although acoustic bubble activity is often characterized as chaotic, the short-duration histotripsy pulses produce a unique and consistent type of cavitation for tissue destruction. In this review, the action of histotripsy-induced bubbles is discussed. Sources of bubble nuclei are reviewed, and bubble activity over the course of single and multiple pulses is outlined. Recent innovations in terms of novel acoustic excitations, exogenous nuclei for targeted ablation and histotripsy-enhanced drug delivery and image guidance metrics are discussed. Finally, gaps in knowledge of the histotripsy process are highlighted, along with suggested means to expedite widespread clinical utilization of histotripsy.
Collapse
Affiliation(s)
- Kenneth B Bader
- Department of Radiology and Committee on Medical Physics, University of Chicago, Chicago, Illinois, USA.
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech University, Blacksburg, Virginia, USA
| | - Adam D Maxwell
- Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA
| |
Collapse
|
44
|
Cheng M, Li F, Han T, Yu ACH, Qin P. Effects of ultrasound pulse parameters on cavitation properties of flowing microbubbles under physiologically relevant conditions. ULTRASONICS SONOCHEMISTRY 2019; 52:512-521. [PMID: 30642801 DOI: 10.1016/j.ultsonch.2018.12.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 12/03/2018] [Accepted: 12/20/2018] [Indexed: 06/09/2023]
Abstract
Acoustic cavitation from ultrasound-driven microbubbles can induce diverse bioeffects that are useful in clinical therapy. However, lack of control over the cavitation activity of flowing microbubbles results in unwanted treatment regions in the targeted tissue, which influences the therapeutic efficacy and bio-safety. The aim of this study is to understand the relationship between the ultrasound pulse parameters and cavitation properties of flowing microbubbles, including the type (and transition between types), threshold, intensity and temporal distribution of cavitation. An in vitro physiological-flow phantom was fabricated, in which the microbubbles had a constant velocity, and were sonicated to a 1-MHz focused transducer at a wide range of peak negative pressures (PNPs) (0.10-1.28 MPa), pulse repetition frequencies (PRFs) (1-200 Hz) and pulse lengths (PLs) (10-400 μs). The signals from the flowing bubbles were passively detected by another 7.5-MHz plane transducer. From detailed time- and frequency-domain analysis, we found 1). The occurrence of stable cavitation (SC) and inertial cavitation (IC) depended on PNP and PL when the PRF was below a critical value (PRF threshold) that related to the fluid velocity and PNP full width at half maximum diameter of the transducer. 2) Below the PRF threshold, the PL had no influence on the temporal distribution of SC intensity; however, above the PRF threshold, the SC properties depended on the PL because of acoustically-driven diffusion. Specifically, at shorter PLs, the SC intensity had a uniform temporal distribution and was independent of the PRF; at longer PLs, the SC intensity correlated negatively with the PRF. 3) Below the PRF threshold, the IC properties were independent of the PRF. Increasing the PRF above the PRF threshold caused the IC intensity to decrease with a non-uniform temporal distribution. These results indicate that the fluid velocity and a pulsed acoustic field influence the number and properties of the replenished bubbles into the targeted region, resulting in the change of cavitation properties. In future therapeutic applications, the physiological fluid conditions must be taken into consideration to design reasonable pulse parameters and achieve desirable cavitation properties.
Collapse
Affiliation(s)
- Mouwen Cheng
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Fan Li
- Department of Medical Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Tao Han
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Alfred C H Yu
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Peng Qin
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
45
|
Mercado-Shekhar KP, Kleven RT, Aponte Rivera H, Lewis R, Karani KB, Vos HJ, Abruzzo TA, Haworth KJ, Holland CK. Effect of Clot Stiffness on Recombinant Tissue Plasminogen Activator Lytic Susceptibility in Vitro. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2710-2727. [PMID: 30268531 PMCID: PMC6551517 DOI: 10.1016/j.ultrasmedbio.2018.08.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 08/01/2018] [Accepted: 08/10/2018] [Indexed: 05/05/2023]
Abstract
The lytic recombinant tissue plasminogen activator (rt-PA) is the only drug approved by the Food and Drug Administration for treating ischemic stroke. Less than 40% of patients with large vessel occlusions who are treated with rt-PA have improved blood flow. However, up to 6% of all patients receiving rt-PA develop intracerebral hemorrhage. Predicting the efficacy of rt-PA treatment a priori could help guide therapeutic decision making, such that rt-PA is administered only to those individuals who would benefit from this treatment. Clot composition and structure affect the lytic efficacy of rt-PA and have an impact on elasticity. However, the relationship between clot elasticity and rt-PA lytic susceptibility has not been adequately investigated. The goal of this study was to quantify the relationship between clot elasticity and rt-PA susceptibility in vitro. Human and porcine highly retracted and mildly retracted clots were fabricated in glass pipettes. The rt-PA lytic susceptibility was evaluated in vitro using the percent clot mass loss. The Young's moduli of the clots were estimated using ultrasound-based single-track-location shear wave elasticity imaging. The percent mass loss in mildly retracted porcine and human clots (28.9 ± 6.1% and 45.2 ± 7.1%, respectively) was significantly higher (p < 0.05) than in highly retracted porcine and human clots (10.9 ± 2.1% and 25.5 ± 10.0%, respectively). Furthermore, the Young's moduli of highly retracted porcine and human clots (5.33 ± 0.92 and 3.21 ± 1.97 kPa, respectively) were significantly higher (p < 0.05) than those of mildly retracted porcine and human clots (2.66 ± 0.55 and 0.79 ± 0.21 kPa, respectively). The results revealed an inverse relationship between the percent clot mass loss and Young's modulus. These findings motivate continued investigation of ultrasound-based methods to assess clot stiffness in order to predict rt-PA thrombolytic efficacy.
Collapse
Affiliation(s)
- Karla P Mercado-Shekhar
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA.
| | - Robert T Kleven
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Hermes Aponte Rivera
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Ryden Lewis
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Kunal B Karani
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Hendrik J Vos
- Department of Biomedical Engineering, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Todd A Abruzzo
- Department of Radiology, Cincinnati Children's Hospital, Cincinnati, Ohio, USA
| | - Kevin J Haworth
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| | - Christy K Holland
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, USA
| |
Collapse
|
46
|
Crake C, Papademetriou IT, Zhang Y, Vykhodtseva N, McDannold NJ, Porter TM. Simultaneous Passive Acoustic Mapping and Magnetic Resonance Thermometry for Monitoring of Cavitation-Enhanced Tumor Ablation in Rabbits Using Focused Ultrasound and Phase-Shift Nanoemulsions. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2609-2624. [PMID: 30201425 PMCID: PMC6215518 DOI: 10.1016/j.ultrasmedbio.2018.07.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 05/01/2018] [Accepted: 07/24/2018] [Indexed: 05/19/2023]
Abstract
Thermal ablation of solid tumors via focused ultrasound (FUS) is a non-invasive image-guided alternative to conventional surgical resection. However, the usefulness of the technique is limited in vascularized organs because of convection of heat, resulting in long sonication times and unpredictable thermal lesion formation. Acoustic cavitation has been found to enhance heating but requires use of exogenous nuclei and sufficient acoustic monitoring. In this study, we employed phase-shift nanoemulsions (PSNEs) to promote cavitation and incorporated passive acoustic mapping (PAM) alongside conventional magnetic resonance imaging (MRI) thermometry within the bore of a clinical MRI scanner. Simultaneous PAM and MRI thermometry were performed in an in vivo rabbit tumor model, with and without PSNE to promote cavitation. Vaporization and cavitation of the nanoemulsion could be detected using PAM, which led to accelerated heating, monitored with MRI thermometry. The maximum heating assessed from MRI was well correlated with the integrated acoustic emissions, illustrating cavitation-enhanced heating. Examination of tissue revealed thermal lesions that were larger in the presence of PSNE, in agreement with the thermometry data. Using fixed exposure conditions over 94 sonications in multiple animals revealed an increase in the mean amplitude of acoustic emissions and resulting temperature rise, but with significant variability between sonications, further illustrating the need for real-time monitoring. The results indicate the utility of combined PAM and MRI for monitoring of tumor ablation and provide further evidence for the ability of PSNEs to promote cavitation-enhanced lesioning.
Collapse
Affiliation(s)
- Calum Crake
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | | | - Yongzhi Zhang
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Natalia Vykhodtseva
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Nathan J McDannold
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Tyrone M Porter
- Department of Mechanical Engineering, Boston University, Boston, Massachusetts, USA; Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA
| |
Collapse
|
47
|
Shi A, Lundt J, Deng Z, Macoskey J, Gurm H, Owens G, Zhang X, Hall TL, Xu Z. Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2697-2709. [PMID: 30279032 PMCID: PMC6215517 DOI: 10.1016/j.ultrasmedbio.2018.08.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 08/16/2018] [Accepted: 08/17/2018] [Indexed: 05/04/2023]
Abstract
After the collapse of a cavitation bubble cloud, residual microbubbles can persist for up to seconds and function as weak cavitation nuclei for subsequent pulses in a phenomenon known as cavitation memory effect. In histotripsy, the cavitation memory effect can cause bubble clouds to repeatedly form at the same discrete set of sites. This effect limits the efficacy of histotripsy-based tissue fractionation. Our previous studies have indicated that low-amplitude bubble-coalescing (BC) ultrasound sequences interleaved with high-amplitude histotripsy pulses can coalesce the residual bubbles into one large bubble quickly. This reduces the cavitation memory effect and may increase treatment efficacy. Histotripsy has been investigated for thrombolysis by breaking up clots into debris smaller than red blood cells. However, this treatment has low efficacy for aged or retracted clots. In this study, we investigate the use of histotripsy with BC to improve the efficacy of treatment of retracted clots. An integrated histotripsy and bubble-coalescing (HBC) transducer system with specialized electronic driving system was built in-house. One high-amplitude (32 MPa), one-cycle histotripsy pulse followed by 36 low-amplitude (2.4 MPa), one-cycle BC pulses formed one HBC sequence. Results indicate that HBC sequences successfully generated a flow channel through the retracted clots at scan speeds of 0.2-0.5 mm/s. The channel size created using the HBC sequence was 128% to 480% larger than that created using histotripsy alone. The clot debris particles generated during HBC treatments were within the tolerable range. These results illustrate the concept that BC improves the treatment efficacy of histotripsy thrombolysis for retracted clots.
Collapse
Affiliation(s)
- Aiwei Shi
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
| | - Jonathan Lundt
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Zilin Deng
- Department of Biomedical Engineering, Beihang University, Beijing, China
| | - Jonathan Macoskey
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Hitinder Gurm
- Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Gabe Owens
- Division of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA
| | - Xi Zhang
- Fitbit Corporation, San Francisco, California, USA
| | - Timothy L Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Division of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
48
|
Opening the Blood-Brain Barrier and Improving the Efficacy of Temozolomide Treatments of Glioblastoma Using Pulsed, Focused Ultrasound with a Microbubble Contrast Agent. BIOMED RESEARCH INTERNATIONAL 2018; 2018:6501508. [PMID: 30534564 PMCID: PMC6252217 DOI: 10.1155/2018/6501508] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 10/22/2018] [Accepted: 10/30/2018] [Indexed: 11/17/2022]
Abstract
Objective To explore the effects of pulsed, focused, and microbubble contrast agent-enhanced ultrasonography (mCEUS) on blood-brain barrier (BBB) permeability and the efficacy temozolomide for glioblastoma. Methods Wistar rats (n = 30) were divided into three groups (n = 10 per group) to determine optimal CUES conditions for achieving BBB permeability, as assessed by ultrastructure transmission electron microscopy (TEM) and western blot assays for the tight junction protein claudin-5. Optimized mCEUS effects on BBB permeability were subsequently confirmed with Evans blue staining (2 groups of 10 rats). The glioma cell line 9L was injected into the brain striatum of Wistar rats. After temozolomide chemotherapy, we detected glial fibrillary acidic protein (GFAP) levels in serum by enzyme-linked immunosorbent assay (ELISA) and in brain tissue by western blot, immunocytochemistry, and real-time quantitative polymerase chain reaction (qPCR). Results BBB permeability was maximized with 1 ml/kg contrast agent mCEUS delivered via 10-min intermittent launches with a 400-ms interval. Evans blue staining confirmed BBB permeability following ultrasonic cavitation in the control group (P < 0.05). Following temozolomide chemotherapy, levels of the tumor marker GFAP were increased in the group with ultrasonic cavitation compared with the control group (P < 0.05). Conclusions When rats were treated by mCEUS with intermittent launches (interval, 400 ms) and injected with 1 mg/kg contrast agent, BBB permeability was increased and temozolomide BBB penetration was enhanced, therapeutic enhancement for glioblastoma.
Collapse
|
49
|
Zafar A, Quadri SA, Farooqui M, Ortega-Gutiérrez S, Hariri OR, Zulfiqar M, Ikram A, Khan MA, Suriya SS, Nunez-Gonzalez JR, Posse S, Mortazavi MM, Yonas H. MRI-Guided High-Intensity Focused Ultrasound as an Emerging Therapy for Stroke: A Review. J Neuroimaging 2018; 29:5-13. [PMID: 30295987 DOI: 10.1111/jon.12568] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Accepted: 09/21/2018] [Indexed: 01/23/2023] Open
Abstract
Stroke, either ischemic or hemorrhagic, accounts for significantly high morbidity and mortality rates around the globe effecting millions of lives annually. For the past few decades, ultrasound has been extensively investigated to promote clot lysis for the treatment of stroke, myocardial infarction, and acute peripheral arterial occlusions, with or without the use of tPA or contrast agents. In the age of modern minimal invasive techniques, magnetic resonance imaging-guided high-intensity focused ultrasound is a new emerging modality that seems to promise therapeutic utilities for both ischemic and hemorrhagic stroke. High-intensity focused ultrasound causes thermal heating as the tissue absorbs the mechanical energy transmitted by the ultrasonic waves leading to tissue denaturation and coagulation. Several in-vitro and in-vivo studies have demonstrated the viability of this technology for sonothrombolysis in both types of stroke and have warranted clinical trials. Apart from safety and efficacy, initiation of trials would further enable answers regarding its practical application in a clinical setup. Though this technology has been under study for treatment of various brain diseases for some decades now, relatively very few neurologists and even neurosurgeons seem to be acquainted with it. The aim of this review is to provide basic understanding of this powerful technology and discuss its clinical application and potential role as an emerging viable therapeutic option for the future management of stroke.
Collapse
Affiliation(s)
- Atif Zafar
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM
| | - Syed A Quadri
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM.,California Institute of Neuroscience, Thousand Oaks, CA.,National Skull Base Center, Thousand Oaks, CA
| | - Mudassir Farooqui
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM
| | | | - Omid R Hariri
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, CA
| | - Maryam Zulfiqar
- Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Asad Ikram
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM
| | - Muhammad Adnan Khan
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM.,California Institute of Neuroscience, Thousand Oaks, CA.,National Skull Base Center, Thousand Oaks, CA
| | - Sajid S Suriya
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM.,California Institute of Neuroscience, Thousand Oaks, CA.,National Skull Base Center, Thousand Oaks, CA
| | | | - Stefan Posse
- Department of Neurology, University of New Mexico Hospitals, Albuquerque, NM
| | - Martin M Mortazavi
- California Institute of Neuroscience, Thousand Oaks, CA.,National Skull Base Center, Thousand Oaks, CA
| | - Howard Yonas
- Department of Neurosurgery, University of New Mexico, Albuquerque, NM
| |
Collapse
|
50
|
Liu X, Wang B, Ding H, Shi H, Liu J, Sun H. Low-intensity pulsed ultrasound in combination with SonoVue induces cytotoxicity of human renal glomerular endothelial cells via repression of the ERK1/2 signaling pathway. Ren Fail 2018; 40:458-465. [PMID: 30122107 PMCID: PMC6104615 DOI: 10.1080/0886022x.2018.1487868] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2022] Open
Abstract
OBJECTIVES Low-intensity pulsed ultrasound (LIPUS) and SonoVue have been used widely for diagnosis and therapeutic treatment. The effects of LIPUS and SonoVue on the microvascular system and underlying molecular mechanisms have not been established. METHODS Cultured human renal glomerular endothelial cells (HRGECs) were treated with 5-min ultrasonic irradiation, 20% SonoVue or the combination of both treatments. Cell proliferation, viablity, and apoptosis were measured by MTT assay, Trypan blue exclusion assay and flow cytometry, respectively. Activation of extracellular regulated protein kinases (ERK) were examined by Western blot. RESULTS We found that LIPUS and SonoVue alone do not induce cytotoxicity of HRGECs; however, the combination of the two treatments reduces cell proliferation and increases cell death. In addition, the combination of LIPUS and SonoVue suppressed the activation of ERK 1/2 in HRGRCs. With pretreatment of the inhibitor of ERK1/2 signaling, PD98059, LIPUS, and SonoVue does not induce additional cell death and inhibition of proliferation. CONCLUSIONS LIPUS combined with SonoVue induces cytotoxicity of HRGECs via repression of the ERK1/2 signaling pathway.
Collapse
Affiliation(s)
- Xiu Liu
- a Shandong Provincial Qianfoshan Hospital, Shandong University , Jinan , China.,b Department of Cardiography , Yantai Affiliated Hospital of Binzhou Medical University , Yantai , China
| | - Bei Wang
- c Department of Ultrasonography , Shandong Provincial Qianfoshan Hospital, Shandong University , Jinan , China
| | - Hongyu Ding
- c Department of Ultrasonography , Shandong Provincial Qianfoshan Hospital, Shandong University , Jinan , China
| | - Hao Shi
- d Department of Radiology, Shandong Provincial Qianfoshan Hospital , Shandong University , Jinan , China
| | - Ju Liu
- e Medical Research Center, Shandong Provincial Qianfoshan Hospital, Shandong University , Jinan , China
| | - Hongjun Sun
- e Medical Research Center, Shandong Provincial Qianfoshan Hospital, Shandong University , Jinan , China
| |
Collapse
|