1
|
Lavenir L, Santos JC, Zemiti N, Kaderbay A, Venail F, Poignet P. Miniaturized Endoscopic 2D US Transducer for Volumetric Ultrasound Imaging of the Auditory System. IEEE Trans Biomed Eng 2023; 70:2624-2635. [PMID: 37027277 DOI: 10.1109/tbme.2023.3260683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
OBJECTIVE In this paper, we focus on the carrying out and validation of minimally invasive three-dimensional (3D) ultrasound (US) imaging of the auditory system, which is based on a new miniaturized endoscopic 2D US transducer. METHODS This unique probe consists of a 18 MHz 24 elements curved array transducer with a distal diameter of 4 mm so it can be inserted into the external auditory canal. Typical acquisition is achieved by rotating such a transducer around its own axis using a robotic platform. Reconstruction of a US volume from the set of acquired B-scans during the rotation is then performed using scan-conversion. The accuracy of the reconstruction procedure is evaluated using a dedicated phantom that includes a set of wires as reference geometry. RESULTS Twelve acquisitions obtained from different probe poses are compared to a micro-computed tomographic model of the phantom, leading to a maximum error of 0.20 mm. Additionally, acquisitions with a cadaveric head highlight the clinical applicability of this set up. Structures of the auditory system such as the ossicles and the round window can be identified from the obtained 3D volumes. CONCLUSION These results confirm that our technique enables the accurate imaging of the middle and inner ears without having to deteriorate the surrounding bone. SIGNIFICANCE Since US is a real-time, wide available and non-ionizing imaging modality, our acquisition setup could facilitate the minimally invasive diagnosis and surgical navigation for otology in a fast, cost-effective and safe way.
Collapse
|
2
|
Feasibility of Cochlea High-frequency Ultrasound and Microcomputed Tomography Registration for Cochlear Computer-assisted Surgery: A Testbed. Otol Neurotol 2021; 42:e779-e787. [PMID: 33871251 DOI: 10.1097/mao.0000000000003091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION There remains no standard imaging method that allows computer-assisted surgery of the cochlea in real time. However, recent evidence suggests that high-frequency ultrasound (HFUS) could permit real-time visualization of cochlear architecture. Registration with an imaging modality that suffers neither attenuation nor conical deformation could reveal useful anatomical landmarks to surgeons. Our study aimed to address the feasibility of an automated three-dimensional (3D) HFUS/microCT registration, and to evaluate the identification of cochlear structures using 2D/3D HFUS and microCT. METHODS MicroCT, and 2D/3D 40 MHz US in B-mode were performed on ex vivo guinea pig cochlea. An automatic rigid registration algorithm was applied to segmented 3D images. This automatic registration was then compared to a reference method using manual annotated landmarks placed by two senior otologists. Inter- and intrarater reliabilities were evaluated using intraclass correlation coefficient (ICC) and the mean registration error was calculated. RESULTS 3D HFUS/microCT automatic registration was successful. Excellent levels of concordance were achieved with regards intra-rater reliability for both raters with micro-CT and US images (ICC ranging from 0.98 to 1, p < 0.001) and with regards inter-rater reliability (ICC ranging from 0.99 to 1, p < 0.001). The mean HFUS/microCT automated RE for both observers was 0.17 ± 0.03 mm [0.10-0.25]. Identification of the basilar membrane, modiolus, scala tympani, and scala vestibuli was possible with 2D/3D HFUS and micro-CT. CONCLUSIONS HFUS/microCT image registration is feasible. 2D/3D HFUS and microCT allow the visualization of cochlear structures. Many potential clinical applications are conceivable.
Collapse
|
3
|
Lavenir L, Zemiti N, Akkari M, Subsol G, Venail F, Poignet P. HFUS Imaging of the Cochlea: A Feasibility Study for Anatomical Identification by Registration with MicroCT. Ann Biomed Eng 2020; 49:1308-1317. [PMID: 33128180 DOI: 10.1007/s10439-020-02671-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 10/21/2020] [Indexed: 11/25/2022]
Abstract
Cochlear implantation consists in electrically stimulating the auditory nerve by inserting an electrode array inside the cochlea, a bony structure of the inner ear. In the absence of any visual feedback, the insertion results in many cases of damages of the internal structures. This paper presents a feasibility study on intraoperative imaging and identification of cochlear structures with high-frequency ultrasound (HFUS). 6 ex-vivo guinea pig cochleae were subjected to both US and microcomputed tomography (µCT) we respectively referred as intraoperative and preoperative modalities. For each sample, registration based on simulating US from the scanner was performed to allow a precise matching between the visible structures. According to two otologists, the procedure led to a target registration error of 0.32 mm ± 0.05. Thanks to referring to a better preoperative anatomical representation, we were able to intraoperatively identify the modiolus, both scalae vestibuli and tympani and deduce the location of the basilar membrane, all of which is of great interest for cochlear implantation. Our main objective is to extend this procedure to the human case and thus provide a new tool for inner ear surgery.
Collapse
Affiliation(s)
- Lucas Lavenir
- LIRMM, University of Montpellier, CNRS, Montpellier, France
| | - Nabil Zemiti
- LIRMM, University of Montpellier, CNRS, Montpellier, France.
| | - Mohamed Akkari
- Department of ENT and Head and Neck Surgery, University Hospital Gui de Chauliac, University of Montpellier, Montpellier, France
| | - Gérard Subsol
- LIRMM, University of Montpellier, CNRS, Montpellier, France
| | - Frédéric Venail
- Department of ENT and Head and Neck Surgery, University Hospital Gui de Chauliac, University of Montpellier, Montpellier, France.,Institute for Neurosciences of Montpellier, INSERM U105, Montpellier, France
| | | |
Collapse
|
4
|
Novozhilov AA, Shilyagin PA, Shakhov AV, Gelikonov VM. [Overview of modern methods for the diagnosis of exudative otitis media]. Vestn Otorinolaringol 2020; 85:68-74. [PMID: 32628387 DOI: 10.17116/otorino20208503168] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Modern methods for diagnosis of exudative otitis media (EOM) have great potential, however, the problem of diagnosis of EOM is still relevant. The article describes the methods of modern diagnostics that are widely used in the daily practice of an otolaryngologist. The basic principles, advantages and disadvantages of generally accepted diagnostic methods for EOM are presented. The method of optical coherence tomography (OCT) is described as a method of studying biological tissues, which is used in many fields of medicine. Information is provided on the possibilities of OCT in the diagnosis of diseases of the ENT organs and, in particular, of the middle ear. The results of studies of the tympanic cavity structures in various inflammatory conditions, the possibilities of intrasurgery use of OCT, as well as the possibilities and perspectives of introducing OCT into the practice of an otorhinolaryngologist in the diagnosis of exudative otitis media are described.
Collapse
Affiliation(s)
- A A Novozhilov
- Privolzhsky Regional Medical Center of the FMBA of Russia, Nizhny Novgorod, Russia
- Institute of Applied Physics of RAS, Nizhny Novgorod, Russia
| | - P A Shilyagin
- Institute of Applied Physics of RAS, Nizhny Novgorod, Russia
| | - A V Shakhov
- Privolzhsky Regional Medical Center of the FMBA of Russia, Nizhny Novgorod, Russia
- Institute of Applied Physics of RAS, Nizhny Novgorod, Russia
- Privolzhsky Research Medical University of the Ministry of Health of Russia, Nizhny Novgorod, Russia
| | - V M Gelikonov
- Institute of Applied Physics of RAS, Nizhny Novgorod, Russia
| |
Collapse
|
5
|
Burwood GWS, Fridberger A, Wang RK, Nuttall AL. Revealing the morphology and function of the cochlea and middle ear with optical coherence tomography. Quant Imaging Med Surg 2019; 9:858-881. [PMID: 31281781 PMCID: PMC6571188 DOI: 10.21037/qims.2019.05.10] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2019] [Accepted: 05/09/2019] [Indexed: 01/17/2023]
Abstract
Optical coherence tomography (OCT) has revolutionized physiological studies of the hearing organ, the vibration and morphology of which can now be measured without opening the surrounding bone. In this review, we provide an overview of OCT as used in the otological research, describing advances and different techniques in vibrometry, angiography, and structural imaging.
Collapse
Affiliation(s)
- George W. S. Burwood
- Department of Otolaryngology, Oregon Hearing Research Center/HNS, Oregon Health & Science University, Portland, OR, USA
| | - Anders Fridberger
- Department of Otolaryngology, Oregon Hearing Research Center/HNS, Oregon Health & Science University, Portland, OR, USA
- Department of Clinical and Experimental Medicine, Section for Neurobiology, Linköping University, Linköping, Sweden
| | - Ruikang K. Wang
- Department of Bioengineering and Department of Ophthalmology, University of Washington, Seattle, WA, USA
| | - Alfred L. Nuttall
- Department of Otolaryngology, Oregon Hearing Research Center/HNS, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
6
|
Dahroug B, Tamadazte B, Weber S, Tavernier L, Andreff N. Review on Otological Robotic Systems: Toward Microrobot-Assisted Cholesteatoma Surgery. IEEE Rev Biomed Eng 2018; 11:125-142. [PMID: 29994589 DOI: 10.1109/rbme.2018.2810605] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Otologic surgical procedures over time have become minimally invasive due to the development of medicine, microtechniques, and robotics. This trend then provides an expected reduction in the patient's recovery time and improvement in the accuracy of diagnosis and treatment. One of the most challenging difficulties that such techniques face are precise control of the instrument and supply of an ergonomic system to the surgeon. The objective of this literature review is to present requirements and guidelines for a surgical robotic system dedicated to middle ear surgery. This review is particularly focused on cholesteatoma surgery (diagnosis and surgical tools), which is one of the most frequent pathologies that urge for an enhanced treatment. This review also presents the current robotic systems that are implemented for otologic applications.
Collapse
|
7
|
Challenges and opportunities in developing targeted molecular imaging to determine inner ear defects of sensorineural hearing loss. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2017; 14:397-404. [PMID: 29074310 DOI: 10.1016/j.nano.2017.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 10/05/2017] [Accepted: 10/13/2017] [Indexed: 12/30/2022]
Abstract
The development of inner ear gene carriers and delivery systems has enabled genetic defects to be repaired and hearing to be restored in mouse models. Today, promising advances in translational therapies provide confidence that targeted molecular therapy for inner ear diseases will be developed. Unfortunately, the currently available non-invasive modalities, such as Computerized Tomography scan or Magnetic Resonance Imaging provide insufficient resolution to identify most pathologies of the human inner ear, even when the current generation of contrast agents is utilized. The development of targeted contrast agents may play a critical role in determining the cause of, and treatment for, sensorineural hearing loss. Such agents should be able to pass through the cochlea barriers, possess minimal cytotoxicity, and easily conjugate to a targeting agent, without distorting the anatomic details. This review focuses on a series of contrast agents which may fit these criteria for potential clinical application.
Collapse
|
8
|
Samson CA, Bezanson A, Brown JA. A Sub-Nyquist, Variable Sampling, High-Frequency Phased Array Beamformer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:568-576. [PMID: 28055864 DOI: 10.1109/tuffc.2016.2646925] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A digital receive beamformer implementing a "one sample per pixel" variable sampling technique is described. The sampling method reduces the required sampling rates by a factor of 3, and reduces the data capture rate by a factor of 2, in comparison with the previous systems based on variable sampling. The sampling method is capable of estimating broadband pulse envelopes accurate for bandwidths up to 83.0%. This beamforming method has been implemented on a field-programmable gate array with maximum transmit and receive delay errors measured to be less than ±1.0 ns. The beamformer was tested and verified on a previously described 45-MHz 64-element phased array. The system generates images with 128 lines, 512 pixels per RF line, and 2 transmit focal zones. The system generates images with approximately 55 dB of dynamic range and was tested by imaging wire targets submersed in a water bath, wire targets embedded in a tissue phantom, and real-time in vivo imaging of a human wrist.
Collapse
|
9
|
MacDougall D, Farrell J, Brown J, Bance M, Adamson R. Long-range, wide-field swept-source optical coherence tomography with GPU accelerated digital lock-in Doppler vibrography for real-time, in vivo middle ear diagnostics. BIOMEDICAL OPTICS EXPRESS 2016; 7:4621-4635. [PMID: 27896001 PMCID: PMC5119601 DOI: 10.1364/boe.7.004621] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/19/2016] [Accepted: 08/24/2016] [Indexed: 05/20/2023]
Abstract
We present the design, implementation and validation of a swept-source optical coherence tomography (OCT) system for real-time imaging of the human middle ear in live patients. Our system consists of a highly phase-stable Vernier-tuned distributed Bragg-reflector laser along with a real-time processing engine implemented on a graphics processing unit. We use the system to demonstrate, for the first time in live subjects, real-time Doppler measurements of middle ear vibration in response to sound, video rate 2D B-mode imaging of the middle ear and 3D volumetric B-mode imaging. All measurements were performed non-invasively through the intact tympanic membrane demonstrating that the technology is readily translatable to the clinic.
Collapse
Affiliation(s)
- Dan MacDougall
- School of Biomedical Engineering, Dalhousie University, 5981 University Ave, Halifax NS, B3H4R2,
Canada
| | - Joshua Farrell
- School of Biomedical Engineering, Dalhousie University, 5981 University Ave, Halifax NS, B3H4R2,
Canada
| | - Jeremy Brown
- School of Biomedical Engineering, Dalhousie University, 5981 University Ave, Halifax NS, B3H4R2,
Canada
- Department of Electrical and Computer Engineering, Dalhousie University, 1459 Oxford St, Halifax NS, B3H4R2,
Canada
| | - Manohar Bance
- School of Biomedical Engineering, Dalhousie University, 5981 University Ave, Halifax NS, B3H4R2,
Canada
- Department of Surgery, Dalhousie University, 1276 South Park St, Halifax NS, B3H2Y9,
Canada
| | - Robert Adamson
- School of Biomedical Engineering, Dalhousie University, 5981 University Ave, Halifax NS, B3H4R2,
Canada
- Department of Electrical and Computer Engineering, Dalhousie University, 1459 Oxford St, Halifax NS, B3H4R2,
Canada
| |
Collapse
|
10
|
High Frequency Ex Vivo Ultrasound Imaging of the Middle Ear to Show Simulated Ossicular Pathology. Otol Neurotol 2016; 37:586-92. [DOI: 10.1097/mao.0000000000001003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Real-time imaging of in-vitro human middle ear using high frequency ultrasound. Hear Res 2015; 326:1-7. [DOI: 10.1016/j.heares.2015.03.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 03/16/2015] [Accepted: 03/18/2015] [Indexed: 11/19/2022]
|
12
|
MacDougall D, Rainsbury J, Brown J, Bance M, Adamson R. Optical coherence tomography system requirements for clinical diagnostic middle ear imaging. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:56008. [PMID: 26000794 DOI: 10.1117/1.jbo.20.5.056008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2015] [Accepted: 04/22/2015] [Indexed: 05/03/2023]
Abstract
Noninvasive middle ear imaging using optical coherence tomography (OCT) presents some unique challenges for real-time, clinical use in humans. We present results from a two-dimensional/three-dimensional OCT system built to assess the imaging requirements of clinical middle ear imaging, and the technical challenges associated with them. These include the need to work at a low numerical aperture, the deleterious effects of transtympanic imaging on image quality at the ossicles, sensitivity requirements for clinical fidelity of images at real-time rates, and the high dynamic-range requirements of the ear. We validated the system by imaging cadaveric specimens with simulated disorders to show the clinical applicability of the images. We also provide additional insight into the likely role of OCT in clinical otology.
Collapse
Affiliation(s)
- Dan MacDougall
- Dalhousie University, Faculties of Engineering and Medicine, School of Biomedical Engineering, Dentistry Building, 5981 University Avenue, Halifax, Nova Scotia B3H 4R2, Canada
| | - James Rainsbury
- Dalhousie University, Faculty of Medicine, Department of Surgery, Victoria Building, 1276 South Park Street, Halifax, Nova Scotia B3H 2Y9, Canada
| | - Jeremy Brown
- Dalhousie University, Faculties of Engineering and Medicine, School of Biomedical Engineering, Dentistry Building, 5981 University Avenue, Halifax, Nova Scotia B3H 4R2, Canada
| | - Manohar Bance
- Dalhousie University, Faculties of Engineering and Medicine, School of Biomedical Engineering, Dentistry Building, 5981 University Avenue, Halifax, Nova Scotia B3H 4R2, CanadabDalhousie University, Faculty of Medicine, Department of Surgery, Victoria Buil
| | - Robert Adamson
- Dalhousie University, Faculties of Engineering and Medicine, School of Biomedical Engineering, Dentistry Building, 5981 University Avenue, Halifax, Nova Scotia B3H 4R2, Canada
| |
Collapse
|
13
|
Torbatian Z, Garland P, Adamson R, Savage J, Bance M, Brown J. Listening to the cochlea with high-frequency ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:2208-2217. [PMID: 22975040 DOI: 10.1016/j.ultrasmedbio.2012.07.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2012] [Revised: 07/16/2012] [Accepted: 07/19/2012] [Indexed: 06/01/2023]
Abstract
We have developed a high-frequency pulsed-wave Doppler ultrasound probe as a promising minimally-invasive technique for measuring intracochlear mechanics without damaging the cochlea. Using a custom high-frequency ultrasound system, we have measured dynamic motion of intracochlear structures by recording the pulsed-wave Doppler signal resulting from the vibration of the basilar and round window membranes. A 45 MHz needle-mounted Doppler probe was fabricated and placed against the round window membranes of eight different fresh human temporal bones. Pulsed-wave ultrasonic Doppler measurements were performed on the basilar membrane and round window membrane during the application of pure tones to the external ear canal. Doppler vibrational information for acoustic input frequencies ranging from 100-2000 Hz was collected and normalized to the sound pressure in the ear canal. The middle ear resonance, located at approximately 1000 Hz, could be characterized from the membrane velocities, which agreed well with literature values. The maximum normalized mean velocity of the round window and the basilar membrane were 180 μm/s/Pa and 27 μm/s/Pa at 800 Hz. The mean phase difference between the membrane displacements and the applied ear canal sound pressure showed a flat response almost up to 500 Hz where it began to accumulate. This is the first study that reports the application of high frequency pulsed wave Doppler ultrasound for measuring the vibration of basilar membrane through the round window. Since it is not required to open or damage the cochlea, this technique might be applicable for investigating cochlear dynamics, in vivo.
Collapse
Affiliation(s)
- Zahra Torbatian
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.
| | | | | | | | | | | |
Collapse
|
14
|
Campbell AP, Suberman TA, Buchman CA, Fitzpatrick DC, Adunka OF. Flexible cochlear microendoscopy in the gerbil. Laryngoscope 2010; 120:1619-24. [PMID: 20564668 DOI: 10.1002/lary.20979] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES/HYPOTHESIS To validate the scientific utility of flexible cochlear microendoscopy in the gerbil. This model is currently being developed to study the effects of intracochlear electrode positioning on functional parameters. STUDY DESIGN Animal experiments. METHODS A flexible fiberoptic microendoscope featuring a light channel and an outer diameter of 0.4 mm was specially modified to allow intracochlear visualization. Specifically, the focus distance was reduced to 1 mm and the optical properties were modified so that visualization was adequate when submerged in perilymphatic fluid. This endoscope was used to view intracochlear contents and monitor the progress of electrode insertions in 11 gerbils. The endoscopic data estimating the site of damage were compared to postmortem microdissections. RESULTS The endoscope allowed for adequate visualization of intracochlear content in all animals. The site of electrode contact seen in the endoscope was confirmed in the microdissected cochleae in 10 of 11 cases, indicating the endoscope's ability to correctly identify the site of intracochlear trauma in this animal model. CONCLUSIONS The current report demonstrates the feasibility of intracochlear microendoscopy in an animal model of hearing preservation cochlear implantation.
Collapse
Affiliation(s)
- Adam P Campbell
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | | | | | | | | |
Collapse
|
15
|
Subhash HM, Davila V, Sun H, Nguyen-Huynh AT, Nuttall AL, Wang RK. Volumetric in vivo imaging of intracochlear microstructures in mice by high-speed spectral domain optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:036024. [PMID: 20615026 PMCID: PMC3188621 DOI: 10.1117/1.3456554] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2010] [Revised: 04/29/2010] [Accepted: 05/06/2010] [Indexed: 05/17/2023]
Abstract
There is considerable interest in developing new methods for in vivo imaging of the complex anatomy of the mammalian cochlea for clinical as well as fundamental studies. In this study, we explored, the feasibility of spectral domain optical coherence tomography (SD-OCT) for 3-D in vivo imaging of the cochlea in mice. The SD-OCT system employed in this study used a broadband light source centered at 1300 nm, and the imaging speed of the system was 47,000 A-scans per second using the InGaAs camera. The system was capable of providing fully processed, high-resolution B-scan images [512 (axial) x 128 (lateral) pixels] at 280 frames per sec. The 3-D imaging acquisition time for a whole cochlea was approximately 0.45 sec. The traditional SD-OCT structural imaging algorithm was used to reconstruct 3-D cochlear morphology. We demonstrated that SD-OCT can be successfully used for in vivo imaging of important morphological features within the mouse cochlea, such as the otic capsule and structures within, including Reissner's membrane, the basilar membrane, tectorial membrane, organ of Corti, and modiolus of the apical and middle turns.
Collapse
Affiliation(s)
- Hrebesh M Subhash
- Oregon Health and Science University, School of Medicine, Department of Biomedical Engineering, Biophotonics and Imaging Laboratory, 3181 SW Sam Jackson Park Road, Portland, Oregon 97239, USA
| | | | | | | | | | | |
Collapse
|