1
|
Huang G, Lin L, Liu Q, Wu S, Chen J, Zhu R, You H, Sun C. Three-dimensional array of microbubbles sonoporation of cells in microfluidics. Front Bioeng Biotechnol 2024; 12:1353333. [PMID: 38419723 PMCID: PMC10899490 DOI: 10.3389/fbioe.2024.1353333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 01/29/2024] [Indexed: 03/02/2024] Open
Abstract
Sonoporation is a popular membrane disruption technique widely applicable in various fields, including cell therapy, drug delivery, and biomanufacturing. In recent years, there has been significant progress in achieving controlled, high-viability, and high-efficiency cell sonoporation in microfluidics. If the microchannels are too small, especially when scaled down to the cellular level, it still remains a challenge to overcome microchannel clogging, and low throughput. Here, we presented a microfluidic device capable of modulating membrane permeability through oscillating three-dimensional array of microbubbles. Simulations were performed to analyze the effective range of action of the oscillating microbubbles to obtain the optimal microchannel size. Utilizing a high-precision light curing 3D printer to fabricate uniformly sized microstructures in a one-step on both the side walls and the top surface for the generation of microbubbles. These microbubbles oscillated with nearly identical amplitudes and frequencies, ensuring efficient and stable sonoporation within the system. Cells were captured and trapped on the bubble surface by the acoustic streaming and secondary acoustic radiation forces induced by the oscillating microbubbles. At a driving voltage of 30 Vpp, the sonoporation efficiency of cells reached 93.9% ± 2.4%.
Collapse
Affiliation(s)
- Guangyong Huang
- School of Mechanical Engineering, Guangxi University, Nanning, China
- School of Mechanical and Automotive Engineering, Guangxi University of Science and Technology, Liuzhou, China
| | - Lin Lin
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Quanhui Liu
- Animal Science and Technology College, Guangxi University, Nanning, China
| | - Shixiong Wu
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Jiapeng Chen
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Rongxing Zhu
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Hui You
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Cuimin Sun
- School of Computer, Electronics and Information, Guangxi University, Nanning, China
| |
Collapse
|
2
|
Brans V, Gray MD, Sezgin E, Stride EPJ. Protein-Decorated Microbubbles for Ultrasound-Mediated Cell Surface Manipulation. ACS APPLIED BIO MATERIALS 2023; 6:5746-5758. [PMID: 38048163 PMCID: PMC10731656 DOI: 10.1021/acsabm.3c00861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/14/2023] [Accepted: 11/20/2023] [Indexed: 12/06/2023]
Abstract
Delivering cargo to the cell membranes of specific cell types in the body is a major challenge for a range of treatments, including immunotherapy. This study investigates employing protein-decorated microbubbles (MBs) and ultrasound (US) to "tag" cellular membranes of interest with a specific protein. Phospholipid-coated MBs were produced and functionalized with a model protein using a metallochelating complex through an NTA(Ni) and histidine residue interaction. Successful "tagging" of the cellular membrane was observed using microscopy in adherent cells and was promoted by US exposure. Further modification of the MB surface to enable selective binding to target cells was then achieved by functionalizing the MBs with a targeting protein (transferrin) that specifically binds to a receptor on the target cell membrane. Attachment and subsequent transfer of material from MBs functionalized with transferrin to the target cells significantly increased, even in the absence of US. This work demonstrates the potential of these MBs as a platform for the noninvasive delivery of proteins to the surface of specific cell types.
Collapse
Affiliation(s)
- Veerle
A. Brans
- Department
of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DL, U.K.
| | - Michael D. Gray
- Department
of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DL, U.K.
| | - Erdinc Sezgin
- Science
for Life Laboratory, Department of Women’s and Children’s
Health, Karolinska Institutet, 17165 Solna, Sweden
| | - Eleanor P. J. Stride
- Department
of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DL, U.K.
| |
Collapse
|
3
|
Pattinson O, Keller SB, Evans ND, Pierron F, Carugo D. An Acoustic Device for Ultra High-Speed Quantification of Cell Strain During Cell-Microbubble Interaction. ACS Biomater Sci Eng 2023; 9:5912-5923. [PMID: 37747762 PMCID: PMC10565720 DOI: 10.1021/acsbiomaterials.3c00757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 09/11/2023] [Indexed: 09/26/2023]
Abstract
Microbubbles utilize high-frequency oscillations under ultrasound stimulation to induce a range of therapeutic effects in cells, often through mechanical stimulation and permeabilization of cells. One of the largest challenges remaining in the field is the characterization of interactions between cells and microbubbles at therapeutically relevant frequencies. Technical limitations, such as employing sufficient frame rates and obtaining sufficient image resolution, restrict the quantification of the cell's mechanical response to oscillating microbubbles. Here, a novel methodology was developed to address many of these limitations and improve the image resolution of cell-microbubble interactions at high frame rates. A compact acoustic device was designed to house cells and microbubbles as well as a therapeutically relevant acoustic field while being compatible with a Shimadzu HPV-X camera. Cell viability tests confirmed the successful culture and proliferation of cells, and the attachment of DSPC- and cationic DSEPC-microbubbles to osteosarcoma cells was quantified. Microbubble oscillation was observed within the device at a frame rate of 5 million FPS, confirming suitable acoustic field generation and ultra high-speed image capture. High spatial resolution in these images revealed observable deformation in cells following microbubble oscillation and supported the first use of digital image correlation for strain quantification in a single cell. The novel acoustic device provided a simple, effective method for improving the spatial resolution of cell-microbubble interaction images, presenting the opportunity to develop an understanding of the mechanisms driving the therapeutic effects of oscillating microbubbles upon ultrasound exposure.
Collapse
Affiliation(s)
- Oliver Pattinson
- Faculty
of Engineering and Physical Sciences, University
of Southampton, University Road, Southampton SO17 1BJ, United Kingdom
| | - Sara B. Keller
- Department
of Engineering Science, University of Oxford, Old Road, Headington, Oxford OX3 7LD, U.K.
| | - Nicholas D. Evans
- Faculty
of Engineering and Physical Sciences, University
of Southampton, University Road, Southampton SO17 1BJ, United Kingdom
| | - Fabrice Pierron
- Faculty
of Engineering and Physical Sciences, University
of Southampton, University Road, Southampton SO17 1BJ, United Kingdom
| | - Dario Carugo
- Nuffield
Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences
(NDORMS), University of Oxford, Old Road, Headington, Oxford OX3 7LD, United Kingdom
| |
Collapse
|
4
|
LuTheryn G, Ho EML, Choi V, Carugo D. Cationic Microbubbles for Non-Selective Binding of Cavitation Nuclei to Bacterial Biofilms. Pharmaceutics 2023; 15:pharmaceutics15051495. [PMID: 37242736 DOI: 10.3390/pharmaceutics15051495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/06/2023] [Accepted: 05/12/2023] [Indexed: 05/28/2023] Open
Abstract
The presence of multi-drug resistant biofilms in chronic, persistent infections is a major barrier to successful clinical outcomes of therapy. The production of an extracellular matrix is a characteristic of the biofilm phenotype, intrinsically linked to antimicrobial tolerance. The heterogeneity of the extracellular matrix makes it highly dynamic, with substantial differences in composition between biofilms, even in the same species. This variability poses a major challenge in targeting drug delivery systems to biofilms, as there are few elements both suitably conserved and widely expressed across multiple species. However, the presence of extracellular DNA within the extracellular matrix is ubiquitous across species, which alongside bacterial cell components, gives the biofilm its net negative charge. This research aims to develop a means of targeting biofilms to enhance drug delivery by developing a cationic gas-filled microbubble that non-selectively targets the negatively charged biofilm. Cationic and uncharged microbubbles loaded with different gases were formulated and tested to determine their stability, ability to bind to negatively charged artificial substrates, binding strength, and, subsequently, their ability to adhere to biofilms. It was shown that compared to their uncharged counterparts, cationic microbubbles facilitated a significant increase in the number of microbubbles that could both bind and sustain their interaction with biofilms. This work is the first to demonstrate the utility of charged microbubbles for the non-selective targeting of bacterial biofilms, which could be used to significantly enhance stimuli-mediated drug delivery to the bacterial biofilm.
Collapse
Affiliation(s)
- Gareth LuTheryn
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), The Botnar Research Centre, University of Oxford, Windmill Road, Oxford OX3 7HE, UK
- Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton SO17 1BJ, UK
| | - Elaine M L Ho
- Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton SO17 1BJ, UK
- Artificial Intelligence and Informatics, The Rosalind Franklin Institute, Harwell Campus, Didcot OX11 0QX, UK
| | - Victor Choi
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
| | - Dario Carugo
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), The Botnar Research Centre, University of Oxford, Windmill Road, Oxford OX3 7HE, UK
| |
Collapse
|
5
|
Plazonic F, LuTheryn G, Hind C, Clifford M, Gray M, Stride E, Glynne-Jones P, Hill M, Sutton JM, Carugo D. Bactericidal Effect of Ultrasound-Responsive Microbubbles and Sub-inhibitory Gentamicin against Pseudomonas aeruginosa Biofilms on Substrates With Differing Acoustic Impedance. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1888-1898. [PMID: 35798625 DOI: 10.1016/j.ultrasmedbio.2022.05.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 05/10/2022] [Accepted: 05/13/2022] [Indexed: 06/15/2023]
Abstract
The aim of this research was to explore the interaction between ultrasound-activated microbubbles (MBs) and Pseudomonas aeruginosa biofilms, specifically the effects of MB concentration, ultrasound exposure and substrate properties on bactericidal efficacy. Biofilms were grown using a Centre for Disease Control (CDC) bioreactor on polypropylene or stainless-steel coupons as acoustic analogues for soft and hard tissue, respectively. Biofilms were treated with different concentrations of phospholipid-shelled MBs (107-108 MB/mL), a sub-inhibitory concentration of gentamicin (4 µg/mL) and 1-MHz ultrasound with a continuous or pulsed (100-kHz pulse repetition frequency, 25% duty cycle, 0.5-MPa peak-to-peak pressure) wave. The effect of repeated ultrasound exposure with intervals of either 15- or 60-min was also investigated. With polypropylene coupons, the greatest bactericidal effect was achieved with 2 × 5 min of pulsed ultrasound separated by 60 min and a microbubble concentration of 5 × 107 MBs/mL. A 0.76 log (83%) additional reduction in the number of bacteria was achieved compared with the use of an antibiotic alone. With stainless-steel coupons, a 67% (0.46 log) reduction was obtained under the same exposure conditions, possibly due to enhancement of a standing wave field which inhibited MB penetration in the biofilm. These findings demonstrate the importance of treatment parameter selection in antimicrobial applications of MBs and ultrasound in different tissue environments.
Collapse
Affiliation(s)
- Filip Plazonic
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Gareth LuTheryn
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK; Department of Pharmaceutics, School of Pharmacy, University College London, London, UK; National Biofilms Innovation Centre, University of Southampton, Southampton, UK
| | - Charlotte Hind
- UK Health Security Agency, Porton Down, Salisbury, Wiltshire, UK
| | - Melanie Clifford
- UK Health Security Agency, Porton Down, Salisbury, Wiltshire, UK
| | - Michael Gray
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Peter Glynne-Jones
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Martyn Hill
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - J Mark Sutton
- UK Health Security Agency, Porton Down, Salisbury, Wiltshire, UK; Institute of Pharmaceutical Science, King's College London, London, UK
| | - Dario Carugo
- Department of Pharmaceutics, School of Pharmacy, University College London, London, UK.
| |
Collapse
|
6
|
LuTheryn G, Hind C, Campbell C, Crowther A, Wu Q, Keller SB, Glynne-Jones P, Sutton JM, Webb JS, Gray M, Wilks SA, Stride E, Carugo D. Bactericidal and anti-biofilm effects of uncharged and cationic ultrasound-responsive nitric oxide microbubbles on Pseudomonas aeruginosa biofilms. Front Cell Infect Microbiol 2022; 12:956808. [PMID: 35992170 PMCID: PMC9386126 DOI: 10.3389/fcimb.2022.956808] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 07/14/2022] [Indexed: 11/25/2022] Open
Abstract
Bacterial biofilms are a major and ongoing concern for public health, featuring both inherited genetic resistance traits and a conferred innate tolerance to traditional antibiotic therapies. Consequently, there is a growing need for novel methods of drug delivery, to increase the efficacy of antimicrobial agents. This research evaluated the anti-biofilm and bactericidal effects of ultrasound responsive gas-microbubbles (MBs) of either air or nitric oxide, using an in vitro Pseudomonas aeruginosa biofilm model grown in artificial wound medium. The four lipid-based MB formulations evaluated were room-air MBs (RAMBs) and nitric oxide MBs (NOMBs) with no electrical charge, as well as cationic (+) RAMBs+ and NOMBs+. Two principal treatment conditions were used: i) ultrasound stimulated MBs only, and ii) ultrasound stimulated MBs with a sub-inhibitory concentration (4 µg/mL) of the antibiotic gentamicin. The total treatment time was divided into a 60 second passive MB interaction period prior to 40 second ultrasound exposure; each MB formulation was tested in triplicate. Ultrasound stimulated RAMBs and NOMBs without antibiotic achieved reductions in biofilm biomass of 93.3% and 94.0%, respectively. Their bactericidal efficacy however was limited, with a reduction in culturable cells of 26.9% and 65.3%, respectively. NOMBs with sub-inhibitory antibiotic produced the most significant reduction in biofilm biomass, corresponding to a 99.9% (SD ± 5.21%); and a 99.9% (SD ± 0.07%) (3-log) reduction in culturable bacterial cells. Cationic MBs were initially manufactured to promote binding of MBs to negatively charged biofilms, but these formulations also demonstrated intrinsic bactericidal properties. In the absence of antibiotic, the bactericidal efficacy of RAMB+ and NOMB+ was greater that of uncharged counterparts, reducing culturable cells by 84.7% and 86.1% respectively; increasing to 99.8% when combined with antibiotic. This study thus demonstrates the anti-biofilm and bactericidal utility of ultrasound stimulated MBs, and specifically is the first to demonstrate the efficacy of a NOMB for the dispersal and potentiation of antibiotics against bacterial biofilms in vitro. Importantly the biofilm system and complex growth-medium were selected to recapitulate key morphological features of in vivo biofilms. The results us offer new insight for the development of new clinical treatments, for example, in chronic wounds.
Collapse
Affiliation(s)
- Gareth LuTheryn
- University College London (UCL) School of Pharmacy, Department of Pharmaceutics, University College London, London, United Kingdom
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom
- *Correspondence: Gareth LuTheryn, ; ; Dario Carugo, ;
| | - Charlotte Hind
- Healthcare Biotechnology, United Kingdom Health Security Agency (UKHSA), Porton Down, Salisbury, United Kingdom
| | - Christopher Campbell
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom
| | - Aaron Crowther
- University College London (UCL) School of Pharmacy, Department of Pharmaceutics, University College London, London, United Kingdom
| | - Qiang Wu
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Sara B. Keller
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Peter Glynne-Jones
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom
| | - J. Mark Sutton
- Healthcare Biotechnology, United Kingdom Health Security Agency (UKHSA), Porton Down, Salisbury, United Kingdom
| | - Jeremy S. Webb
- School of Biological Sciences, Faculty of Environmental and Life Sciences, National Biofilms Innovation Centre (NBIC) and Institute for Life Sciences, University of Southampton, Southampton, United Kingdom
| | - Michael Gray
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Sandra A. Wilks
- School of Health Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Dario Carugo
- University College London (UCL) School of Pharmacy, Department of Pharmaceutics, University College London, London, United Kingdom
- *Correspondence: Gareth LuTheryn, ; ; Dario Carugo, ;
| |
Collapse
|
7
|
In search of a Mpemba effect protocol: Some hot water does cool and freeze faster than cold. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2021.117043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
8
|
Carugo D, Browning RJ, Iranmanesh I, Messaoudi W, Rademeyer P, Stride E. Scaleable production of microbubbles using an ultrasound-modulated microfluidic device. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:1577. [PMID: 34470259 DOI: 10.1121/10.0005911] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/29/2021] [Indexed: 06/13/2023]
Abstract
Surfactant-coated gas microbubbles are widely used as contrast agents in ultrasound imaging and increasingly in therapeutic applications. The response of microbubbles to ultrasound can be strongly influenced by their size and coating properties, and hence the production method. Ultrasonic emulsification (sonication) is the most commonly employed method and can generate high concentrations of microbubbles rapidly, but with a broad size distribution, and there is a risk of contamination and/or degradation of sensitive components. Microfluidic devices provide excellent control over microbubble size, but are often challenging or costly to manufacture, offer low production rates (<106s-1), and are prone to clogging. In this study, a hybrid sonication-microfluidic or "sonofluidic" device was developed. Bubbles of ∼180 μm diameter were produced rapidly in a T-junction and subsequently exposed to ultrasound (71-73 kHz) within a microchannel, generating microbubbles (mean diameter: 1-2 μm) at a rate of >108s-1 using a single device. Microbubbles were prepared using either the sonofluidic device or conventional sonication, and their size, concentration, and stability were comparable. The mean diameter, concentration, and stability were found to be comparable between techniques, but the microbubbles produced by the sonofluidic device were all <5 μm in diameter and thus did not require any post-production fractionation.
Collapse
Affiliation(s)
- Dario Carugo
- Department of Pharmaceutics, UCL School of Pharmacy, University College London (UCL), London, United Kingdom
| | - Richard J Browning
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Ida Iranmanesh
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Walid Messaoudi
- Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom
| | - Paul Rademeyer
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
9
|
Ruan JL, Browning RJ, Yildiz YO, Bau L, Kamila S, Gray MD, Folkes L, Hampson A, McHale AP, Callan JF, Vojnovic B, Kiltie AE, Stride E. Evaluation of Loading Strategies to Improve Tumor Uptake of Gemcitabine in a Murine Orthotopic Bladder Cancer Model Using Ultrasound and Microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1596-1615. [PMID: 33707089 DOI: 10.1016/j.ultrasmedbio.2021.02.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 02/01/2021] [Accepted: 02/02/2021] [Indexed: 06/12/2023]
Abstract
In this study we compared three different microbubble-based approaches to the delivery of a widely used chemotherapy drug, gemcitabine: (i) co-administration of gemcitabine and microbubbles (Gem+MB); (ii) conjugates of microbubbles and gemcitabine-loaded liposomes (GemlipoMB); and (iii) microbubbles with gemcitabine directly bound to their surfaces (GembioMB). Both in vitro and in vivo investigations were carried out, respectively, in the RT112 bladder cancer cell line and in a murine orthotopic muscle-invasive bladder cancer model. The in vitro (in vivo) ultrasound exposure conditions were a 1 (1.1) MHz centre frequency, 0.07 (1.0) MPa peak negative pressure, 3000 (20,000) cycles and 100 (0.5) Hz pulse repetition frequency. Ultrasound exposure produced no significant increase in drug uptake either in vitro or in vivo compared with the drug-only control for co-administered gemcitabine and microbubbles. In vivo, GemlipoMB prolonged the plasma circulation time of gemcitabine, but only GembioMB produced a statistically significant increase in cleaved caspase 3 expression in the tumor, indicative of gemcitabine-induced apoptosis.
Collapse
Affiliation(s)
- Jia-Ling Ruan
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Richard J Browning
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Yesna O Yildiz
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Luca Bau
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Sukanta Kamila
- Biomedical Sciences Research Institute, University of Ulster, Coleraine, Northern Ireland, United Kingdom
| | - Michael D Gray
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom
| | - Lisa Folkes
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Alix Hampson
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Anthony P McHale
- Biomedical Sciences Research Institute, University of Ulster, Coleraine, Northern Ireland, United Kingdom
| | - John F Callan
- Biomedical Sciences Research Institute, University of Ulster, Coleraine, Northern Ireland, United Kingdom
| | - Borivoj Vojnovic
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Anne E Kiltie
- MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom.
| |
Collapse
|
10
|
Recent advances in micro/nanoscale intracellular delivery. NANOTECHNOLOGY AND PRECISION ENGINEERING 2020. [DOI: 10.1016/j.npe.2019.12.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
Lattwein KR, Shekhar H, Kouijzer JJP, van Wamel WJB, Holland CK, Kooiman K. Sonobactericide: An Emerging Treatment Strategy for Bacterial Infections. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:193-215. [PMID: 31699550 PMCID: PMC9278652 DOI: 10.1016/j.ultrasmedbio.2019.09.011] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 09/03/2019] [Accepted: 09/16/2019] [Indexed: 05/04/2023]
Abstract
Ultrasound has been developed as both a diagnostic tool and a potent promoter of beneficial bio-effects for the treatment of chronic bacterial infections. Bacterial infections, especially those involving biofilm on implants, indwelling catheters and heart valves, affect millions of people each year, and many deaths occur as a consequence. Exposure of microbubbles or droplets to ultrasound can directly affect bacteria and enhance the efficacy of antibiotics or other therapeutics, which we have termed sonobactericide. This review summarizes investigations that have provided evidence for ultrasound-activated microbubble or droplet treatment of bacteria and biofilm. In particular, we review the types of bacteria and therapeutics used for treatment and the in vitro and pre-clinical experimental setups employed in sonobactericide research. Mechanisms for ultrasound enhancement of sonobactericide, with a special emphasis on acoustic cavitation and radiation force, are reviewed, and the potential for clinical translation is discussed.
Collapse
Affiliation(s)
- Kirby R Lattwein
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
| | - Himanshu Shekhar
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Joop J P Kouijzer
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Willem J B van Wamel
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Christy K Holland
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Klazina Kooiman
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| |
Collapse
|
12
|
Aytac-Kipergil E, Alles EJ, Pauw HC, Karia J, Noimark S, Desjardins AE. Versatile and scalable fabrication method for laser-generated focused ultrasound transducers. OPTICS LETTERS 2019; 44:6005-6008. [PMID: 32628218 PMCID: PMC7059213 DOI: 10.1364/ol.44.006005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 10/17/2019] [Indexed: 05/18/2023]
Abstract
A versatile and scalable fabrication method for laser-generated focused ultrasound transducers is proposed. The method is based on stamping a coated negative mold onto polydimethylsiloxane, and it can be adapted to include different optical absorbers that are directly transferred or synthesized in situ. Transducers with a range of sizes down to 3 mm in diameter are presented, incorporating two carbonaceous (multiwalled carbon nanoparticles and candle soot nanoparticles) and one plasmonic (gold nanoparticles) optically absorbing component. The fabricated transducers operate at central frequencies in the vicinity of 10 MHz with bandwidths in the range of 15-20 MHz. A transducer with a diameter of 5 mm was found to generate a positive peak pressure greater than 35 MPa in the focal zone with a tight focal spot of 150 μm in lateral width. Ultrasound cavitation on the tip of an optical fiber was demonstrated in water for a transducer with a diameter as small as 3 mm.
Collapse
Affiliation(s)
- E. Aytac-Kipergil
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
- Corresponding author:
| | - E. J. Alles
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| | - H. C. Pauw
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
| | - J. Karia
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
| | - S. Noimark
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| | - A. E. Desjardins
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| |
Collapse
|
13
|
Roovers S, Deprez J, Priwitaningrum D, Lajoinie G, Rivron N, Declercq H, De Wever O, Stride E, Le Gac S, Versluis M, Prakash J, De Smedt SC, Lentacker I. Sonoprinting liposomes on tumor spheroids by microbubbles and ultrasound. J Control Release 2019; 316:79-92. [PMID: 31676384 DOI: 10.1016/j.jconrel.2019.10.051] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/24/2019] [Accepted: 10/28/2019] [Indexed: 12/12/2022]
Abstract
Ultrasound-triggered drug-loaded microbubbles have great potential for drug delivery due to their ability to locally release drugs and simultaneously enhance their delivery into the target tissue. We have recently shown that upon applying ultrasound, nanoparticle-loaded microbubbles can deposit nanoparticles onto cells grown in 2D monolayers, through a process that we termed "sonoprinting". However, the rigid surfaces on which cell monolayers are typically growing might be a source of acoustic reflections and aspherical microbubble oscillations, which can influence microbubble-cell interactions. In the present study, we aim to reveal whether sonoprinting can also occur in more complex and physiologically relevant tissues, by using free-floating 3D tumor spheroids as a tissue model. We show that both monospheroids (consisting of tumor cells alone) and cospheroids (consisting of tumor cells and fibroblasts, which produce an extracellular matrix) can be sonoprinted. Using doxorubicin-liposome-loaded microbubbles, we show that sonoprinting allows to deposit large amounts of doxorubicin-containing liposomes to the outer cell layers of the spheroids, followed by doxorubicin release into the deeper layers of the spheroids, resulting in a significant reduction in cell viability. Sonoprinting may become an attractive approach to deposit drug patches at the surface of tissues, thereby promoting the delivery of drugs into target tissues.
Collapse
Affiliation(s)
- S Roovers
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| | - J Deprez
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| | - D Priwitaningrum
- Targeted Therapeutics, Department of Biomaterials Science and Technology, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, Enschede, the Netherlands
| | - G Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, Enschede, the Netherlands
| | - N Rivron
- Institute of Molecular Biotechnology, Austrian Academy of Sciences, Vienna, Austria
| | - H Declercq
- Cancer Research Institute Ghent (CRIG), Ghent, Belgium; Tissue Engineering Group, Department of Human Structure and Repair, Ghent University, Belgium
| | - O De Wever
- Cancer Research Institute Ghent (CRIG), Ghent, Belgium; Laboratory Experimental Cancer Research (LECR), Ghent University, Ghent, Belgium
| | - E Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - S Le Gac
- Applied Microfluidics for BioEngineering Research, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, Enschede, the Netherlands
| | - M Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, Enschede, the Netherlands
| | - J Prakash
- Targeted Therapeutics, Department of Biomaterials Science and Technology, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center, University of Twente, Enschede, the Netherlands
| | - S C De Smedt
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium.
| | - I Lentacker
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent (CRIG), Ghent, Belgium
| |
Collapse
|
14
|
Aron M, Vince O, Gray M, Mannaris C, Stride E. Investigating the Role of Lipid Transfer in Microbubble-Mediated Drug Delivery. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:13205-13215. [PMID: 31517490 DOI: 10.1021/acs.langmuir.9b02404] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Sonoporation, the permeabilization of cell membranes following exposure to microbubbles and ultrasound, has considerable potential for therapeutic delivery. To date, engineering of microbubbles for these applications has focused primarily upon optimizing microbubble size and stability, or attachment of targeting species and/or drug molecules. In this work, it is demonstrated that the microbubble coating can also be tailored to directly influence cell permeabilization. Specifically, lipid exchange mechanisms between phospholipid microbubbles and cells can be exploited to significantly increase sonoporation efficiency in vitro. A theoretical analysis of the energy required for pore formation was carried out. From this, it was hypothesized that sonoporation could be promoted by the transfer of lipid molecules with appropriate carbon chain length and/or shape (cylindrical or conical). Spectral imaging with a hydration-sensitive membrane probe (C-Laurdan) was used to measure changes in the membrane lipid order of A-549 cancer cells following exposure to suspensions of different phospholipids. Two candidate lipids were identified, a short-chain-length phospholipid (1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC)) and a medium-chain-length lysolipid (1-palmitoyl-2-hydroxy-sn-glycero-3-phosphocholine (16:0 lyso-PC)). Microbubbles were prepared with matched concentrations, size distributions, and acoustic responses. Confocal microscopy was used to measure cell uptake of a model drug (propidium iodide) with and without ultrasound exposure (1 MHz, 250 kPa peak negative pressure, 1 kHz pulse repetition frequency, 10% duty cycle, 15 s exposure). Despite significantly decreasing the cell membrane lipid order, DLPC did not increase sonoporation. Microbubbles containing 16:0 lyso-PC, however, produced a ∼5-fold increase in sonoporation compared to control microbubbles. Importantly, the lyso-PC molecules were incorporated into the microbubble coating and did not affect cell permeability prior to ultrasound exposure. These findings indicate that microbubbles can be engineered to exploit lipid exchange between microbubble shells and cell membranes to enhance drug delivery, a new optimization route that may lead to enhanced therapeutic efficacy of ultrasound-mediated treatments.
Collapse
Affiliation(s)
- Miles Aron
- Institute of Biomedical Engineering , University of Oxford , Old Road Campus Research Building , Oxford OX3 7DQ , U.K
| | - Oliver Vince
- Institute of Biomedical Engineering , University of Oxford , Old Road Campus Research Building , Oxford OX3 7DQ , U.K
| | - Michael Gray
- Institute of Biomedical Engineering , University of Oxford , Old Road Campus Research Building , Oxford OX3 7DQ , U.K
| | - Christophoros Mannaris
- Institute of Biomedical Engineering , University of Oxford , Old Road Campus Research Building , Oxford OX3 7DQ , U.K
| | - Eleanor Stride
- Institute of Biomedical Engineering , University of Oxford , Old Road Campus Research Building , Oxford OX3 7DQ , U.K
| |
Collapse
|
15
|
Meng L, Liu X, Wang Y, Zhang W, Zhou W, Cai F, Li F, Wu J, Xu L, Niu L, Zheng H. Sonoporation of Cells by a Parallel Stable Cavitation Microbubble Array. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2019; 6:1900557. [PMID: 31508275 PMCID: PMC6724477 DOI: 10.1002/advs.201900557] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/15/2019] [Indexed: 05/06/2023]
Abstract
Sonoporation is a targeted drug delivery technique that employs cavitation microbubbles to generate transient pores in the cell membrane, allowing foreign substances to enter cells by passing through the pores. Due to the broad size distribution of microbubbles, cavitation events appear to be a random process, making it difficult to achieve controllable and efficient sonoporation. In this work a technique is reported using a microfluidic device that enables in parallel modulation of membrane permeability by an oscillating microbubble array. Multirectangular channels of uniform size are created at the sidewall to generate an array of monodispersed microbubbles, which oscillate with almost the same amplitude and resonant frequency, ensuring homogeneous sonoporation with high efficacy. Stable harmonic and high harmonic signals emitted by individual oscillating microbubbles are detected by a laser Doppler vibrometer, which indicates stable cavitation occurred. Under the influence of the acoustic radiation forces induced by the oscillating microbubble, single cells can be trapped at an oscillating microbubble surface. The sonoporation of single cells is directly influenced by the individual oscillating microbubble. The parallel sonoporation of multiple cells is achieved with an efficiency of 96.6 ± 1.74% at an acoustic pressure as low as 41.7 kPa.
Collapse
Affiliation(s)
- Long Meng
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Xiufang Liu
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Sino‐Dutch Biomedical and Information Engineering SchoolNortheastern University195 Innovation roadShenyang110169China
| | - Yuchen Wang
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Faculty of Engineering and ArchitectureGhent UniversityJozef Plateaustraat 229000GhentBelgium
| | - Wenjun Zhang
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Key Laboratory of E&MMinistry of Education & Zhejiang ProvinceZhejiang University of Technology18 Chaowang RoadHangzhou310014China
| | - Wei Zhou
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Feiyan Cai
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Fei Li
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Junru Wu
- Department of PhysicsUniversity of VermontBurlingtonVT05405USA
| | - Lisheng Xu
- Sino‐Dutch Biomedical and Information Engineering SchoolNortheastern University195 Innovation roadShenyang110169China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| |
Collapse
|
16
|
Horsley H, Owen J, Browning R, Carugo D, Malone-Lee J, Stride E, Rohn JL. Ultrasound-activated microbubbles as a novel intracellular drug delivery system for urinary tract infection. J Control Release 2019; 301:166-175. [PMID: 30904501 DOI: 10.1016/j.jconrel.2019.03.017] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2018] [Revised: 03/15/2019] [Accepted: 03/18/2019] [Indexed: 12/27/2022]
Abstract
The development of new modalities for high-efficiency intracellular drug delivery is a priority for a number of disease areas. One such area is urinary tract infection (UTI), which is one of the most common infectious diseases globally and which imposes an immense economic and healthcare burden. Common uropathogenic bacteria have been shown to invade the urothelial wall during acute UTI, forming latent intracellular reservoirs that can evade antimicrobials and the immune response. This behaviour likely facilitates the high recurrence rates after oral antibiotic treatments, which are not able to penetrate the bladder wall and accumulate to an effective concentration. Meanwhile, oral antibiotics may also exacerbate antimicrobial resistance and cause systemic side effects. Using a human urothelial organoid model, we tested the ability of novel ultrasound-activated lipid microbubbles to deliver drugs into the cytoplasm of apical cells. The gas-filled lipid microbubbles were decorated with liposomes containing the non-cell-permeant antibiotic gentamicin and a fluorescent marker. The microbubble suspension was added to buffer at the apical surface of the bladder model before being exposed to ultrasound (1.1 MHz, 2.5 Mpa, 5500 cycles at 20 ms pulse duration) for 20 s. Our results show that ultrasound-activated intracellular delivery using microbubbles was over 16 times greater than the control group and twice that achieved by liposomes that were not associated with microbubbles. Moreover, no cell damage was detected. Together, our data show that ultrasound-activated microbubbles can safely deliver high concentrations of drugs into urothelial cells, and have the potential to be a more efficacious alternative to traditional oral antibiotic regimes for UTI. This modality of intracellular drug delivery may prove useful in other clinical indications, such as cancer and gene therapy, where such penetration would aid in treatment.
Collapse
Affiliation(s)
- H Horsley
- Department of Renal Medicine, Division of Medicine, University College, London, UK
| | - J Owen
- Institute of Biomedical Engineering, University of Oxford, UK
| | - R Browning
- Institute of Biomedical Engineering, University of Oxford, UK
| | - D Carugo
- Faculty of Physical Sciences and Engineering, University of Southampton, UK; Institute for Life Sciences, University of Southampton, UK
| | - J Malone-Lee
- Department of Renal Medicine, Division of Medicine, University College, London, UK
| | - E Stride
- Institute of Biomedical Engineering, University of Oxford, UK
| | - J L Rohn
- Department of Renal Medicine, Division of Medicine, University College, London, UK.
| |
Collapse
|
17
|
Burgess MT, Porter TM. Control of Acoustic Cavitation for Efficient Sonoporation with Phase-Shift Nanoemulsions. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:846-858. [PMID: 30638968 PMCID: PMC8859868 DOI: 10.1016/j.ultrasmedbio.2018.12.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 11/20/2018] [Accepted: 12/03/2018] [Indexed: 05/18/2023]
Abstract
Acoustic cavitation can be used to temporarily disrupt cell membranes for intracellular delivery of large biomolecules. Termed sonoporation, the ability of this technique for efficient intracellular delivery (i.e., >50% of initial cell population showing uptake) while maintaining cell viability (i.e., >50% of initial cell population viable) has proven to be very difficult. Here, we report that phase-shift nanoemulsions (PSNEs) function as inertial cavitation nuclei for improvement of sonoporation efficiency. The interplay between ultrasound frequency, resultant microbubble dynamics and sonoporation efficiency was investigated experimentally. Acoustic emissions from individual microbubbles nucleated from PSNEs were captured using a broadband passive cavitation detector during and after acoustic droplet vaporization with short pulses of ultrasound at 1, 2.5 and 5 MHz. Time domain features of the passive cavitation detector signals were analyzed to estimate the maximum size (Rmax) of the microbubbles using the Rayleigh collapse model. These results were then applied to sonoporation experiments to test if uptake efficiency is dependent on maximum microbubble size before inertial collapse. Results indicated that at the acoustic droplet vaporization threshold, Rmax was approximately 61.7 ± 5.2, 24.9 ± 2.8, and 12.4 ± 2.1 μm at 1, 2.5 and 5 MHz, respectively. Sonoporation efficiency increased at higher frequencies, with efficiencies of 39.5 ± 13.7%, 46.6 ± 3.28% and 66.8 ± 5.5% at 1, 2.5 and 5 MHz, respectively. Excessive cellular damage was seen at lower frequencies because of the erosive effects of highly energetic inertial cavitation. These results highlight the importance of acoustic cavitation control in determining the outcome of sonoporation experiments. In addition, PSNEs may serve as tailorable inertial cavitation nuclei for other therapeutic ultrasound applications.
Collapse
Affiliation(s)
- Mark T Burgess
- Department of Mechanical Engineering, Boston University, Boston, Massachusetts, USA
| | - Tyrone M Porter
- Department of Mechanical Engineering, Boston University, Boston, Massachusetts, USA; Department of Biomedical Engineering, Boston University, Boston, Massachusetts, USA.
| |
Collapse
|
18
|
Abstract
For gene therapy to work in vivo, nucleic acids need to reach the target cells without causing major side effects to the patient. In many cases the gene only has to reach a subset of cells in the body. Therefore, targeted delivery of genes to the desired tissue is a major issue in gene delivery. Many different possibilities of targeted gene delivery have been studied. A physical approach to target nucleic acids and other drugs to specific regions in the body is the use of ultrasound and microbubbles. Microbubbles are gas filled spheres with a stabilizing lipid, protein, or polymer shell. When these microbubbles enter an ultrasonic field, they start to oscillate. The bubbles' expansion and compression are inversely related to the pressure phases in the ultrasonic field. When microbubbles are exposed to high-intensity ultrasound the microbubbles will eventually implode and fragment. This generates shockwaves and microjets which can temporarily permeate cell membranes and blood vessels. Nucleic acids or (non)viral vectors can as a result gain direct access to either the cytoplasm of neighboring cells, or extravasate to the surrounding tissue. The nucleic acids can either be mixed with the microbubbles or loaded on the microbubbles. Nucleic acid loaded microbubbles can be obtained by coupling nucleic acid-containing particles (i.e., lipoplexes) to the microbubbles. Upon ultrasound-mediated implosion of the microbubbles, the nucleic acid-containing particles will be released and will deliver their nucleic acids in the ultrasound-targeted region.
Collapse
|
19
|
Memoli G, Baxter KO, Jones HG, Mingard KP, Zeqiri B. Acoustofluidic Measurements on Polymer-Coated Microbubbles: Primary and Secondary Bjerknes Forces. MICROMACHINES 2018; 9:E404. [PMID: 30424337 PMCID: PMC6187510 DOI: 10.3390/mi9080404] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 08/05/2018] [Accepted: 08/09/2018] [Indexed: 12/27/2022]
Abstract
The acoustically-driven dynamics of isolated particle-like objects in microfluidic environments is a well-characterised phenomenon, which has been the subject of many studies. Conversely, very few acoustofluidic researchers looked at coated microbubbles, despite their widespread use in diagnostic imaging and the need for a precise characterisation of their acoustically-driven behaviour, underpinning therapeutic applications. The main reason is that microbubbles behave differently, due to their larger compressibility, exhibiting much stronger interactions with the unperturbed acoustic field (primary Bjerknes forces) or with other bubbles (secondary Bjerknes forces). In this paper, we study the translational dynamics of commercially-available polymer-coated microbubbles in a standing-wave acoustofluidic device. At increasing acoustic driving pressures, we measure acoustic forces on isolated bubbles, quantify bubble-bubble interaction forces during doublet formation and study the occurrence of sub-wavelength structures during aggregation. We present a dynamic characterisation of microbubble compressibility with acoustic pressure, highlighting a threshold pressure below which bubbles can be treated as uncoated. Thanks to benchmarking measurements under a scanning electron microscope, we interpret this threshold as the onset of buckling, providing a quantitative measurement of this parameter at the single-bubble level. For acoustofluidic applications, our results highlight the limitations of treating microbubbles as a special case of solid particles. Our findings will impact applications where knowing the buckling pressure of coated microbubbles has a key role, like diagnostics and drug delivery.
Collapse
Affiliation(s)
- Gianluca Memoli
- School of Engineering and Informatics, University of Sussex, BN1 9QJ Falmer, UK.
- National Physical Laboratory, TW11 0LW Teddington, UK.
| | - Kate O Baxter
- National Physical Laboratory, TW11 0LW Teddington, UK.
| | - Helen G Jones
- National Physical Laboratory, TW11 0LW Teddington, UK.
| | - Ken P Mingard
- National Physical Laboratory, TW11 0LW Teddington, UK.
| | - Bajram Zeqiri
- National Physical Laboratory, TW11 0LW Teddington, UK.
| |
Collapse
|
20
|
Pereno V, Aron M, Vince O, Mannaris C, Seth A, de Saint Victor M, Lajoinie G, Versluis M, Coussios C, Carugo D, Stride E. Layered acoustofluidic resonators for the simultaneous optical and acoustic characterisation of cavitation dynamics, microstreaming, and biological effects. BIOMICROFLUIDICS 2018; 12:034109. [PMID: 29887932 PMCID: PMC5976496 DOI: 10.1063/1.5023729] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Accepted: 05/09/2018] [Indexed: 05/22/2023]
Abstract
The study of the effects of ultrasound-induced acoustic cavitation on biological structures is an active field in biomedical research. Of particular interest for therapeutic applications is the ability of oscillating microbubbles to promote both cellular and tissue membrane permeabilisation and to improve the distribution of therapeutic agents in tissue through extravasation and convective transport. The mechanisms that underpin the interaction between cavitating agents and tissues are, however, still poorly understood. One challenge is the practical difficulty involved in performing optical microscopy and acoustic emissions monitoring simultaneously in a biologically compatible environment. Here we present and characterise a microfluidic layered acoustic resonator (μLAR) developed for simultaneous ultrasound exposure, acoustic emissions monitoring, and microscopy of biological samples. The μLAR facilitates in vitro ultrasound experiments in which measurements of microbubble dynamics, microstreaming velocity fields, acoustic emissions, and cell-microbubble interactions can be performed simultaneously. The device and analyses presented provide a means of performing mechanistic in vitro studies that may benefit the design of predictable and effective cavitation-based ultrasound treatments.
Collapse
Affiliation(s)
- V. Pereno
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - M. Aron
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - O. Vince
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - C. Mannaris
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - A. Seth
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - M. de Saint Victor
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - G. Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - M. Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - C. Coussios
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - D. Carugo
- Authors to whom correspondence should be addressed: and
| | - E. Stride
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
| |
Collapse
|
21
|
Optical Ultrasound Generation and Detection for Intravascular Imaging: A Review. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:3182483. [PMID: 29854358 PMCID: PMC5952521 DOI: 10.1155/2018/3182483] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 03/09/2018] [Accepted: 03/15/2018] [Indexed: 12/30/2022]
Abstract
Combined ultrasound and photoacoustic imaging has attracted significant interests for intravascular imaging such as atheromatous plaque detection, with ultrasound imaging providing spatial location and morphology and photoacoustic imaging highlighting molecular composition of the plaque. Conventional ultrasound imaging systems utilize piezoelectric ultrasound transducers, which suffer from limited frequency bandwidths and reduced sensitivity with miniature transducer elements. Recent advances on optical methods for both ultrasound generation and detection have shown great promise, as they provide efficient and ultrabroadband ultrasound generation and sensitive and ultrabroadband ultrasound detection. As such, all-optical ultrasound imaging has a great potential to become a next generation ultrasound imaging method. In this paper, we review recent developments on optical ultrasound transmitters, detectors, and all-optical ultrasound imaging systems, with a particular focus on fiber-based probes for intravascular imaging. We further discuss our thoughts on future directions on developing combined all-optical photoacoustic and ultrasound imaging systems for intravascular imaging.
Collapse
|
22
|
Beekers I, van Rooij T, Verweij MD, Versluis M, de Jong N, Trietsch SJ, Kooiman K. Acoustic Characterization of a Vessel-on-a-Chip Microfluidic System for Ultrasound-Mediated Drug Delivery. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:570-581. [PMID: 29610087 DOI: 10.1109/tuffc.2018.2803137] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Ultrasound in the presence of gas-filled microbubbles can be used to enhance local uptake of drugs and genes. To study the drug delivery potential and its underlying physical and biological mechanisms, an in vitro vessel model should ideally include 3-D cell culture, perfusion flow, and membrane-free soft boundaries. Here, we propose an organ-on-a-chip microfluidic platform to study ultrasound-mediated drug delivery: the OrganoPlate. The acoustic propagation into the OrganoPlate was determined to assess the feasibility of controlled microbubble actuation, which is required to study the microbubble-cell interaction for drug delivery. The pressure field in the OrganoPlate was characterized non-invasively by studying experimentally the well-known response of microbubbles and by simulating the acoustic wave propagation in the system. Microbubble dynamics in the OrganoPlate were recorded with the Brandaris 128 ultrahigh-speed camera (17 million frames/s) and a control experiment was performed in an OptiCell, an in vitro monolayer cell culture chamber that is conventionally used to study ultrasound-mediated drug delivery. When insonified at frequencies between 1 and 2 MHz, microbubbles in the OrganoPlate experienced larger oscillation amplitudes resulting from higher local pressures. Microbubbles responded similarly in both systems when insonified at frequencies between 2 and 4 MHz. Numerical simulations performed with a 3-D finite-element model of ultrasound propagation into the OrganoPlate and the OptiCell showed the same frequency-dependent behavior. The predictable and homogeneous pressure field in the OrganoPlate demonstrates its potential to develop an in vitro 3-D cell culture model, well suited to study ultrasound-mediated drug delivery.
Collapse
|
23
|
Aron M, Browning R, Carugo D, Sezgin E, Bernardino de la Serna J, Eggeling C, Stride E. Spectral imaging toolbox: segmentation, hyperstack reconstruction, and batch processing of spectral images for the determination of cell and model membrane lipid order. BMC Bioinformatics 2017; 18:254. [PMID: 28494801 PMCID: PMC5427590 DOI: 10.1186/s12859-017-1656-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2016] [Accepted: 04/26/2017] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Spectral imaging with polarity-sensitive fluorescent probes enables the quantification of cell and model membrane physical properties, including local hydration, fluidity, and lateral lipid packing, usually characterized by the generalized polarization (GP) parameter. With the development of commercial microscopes equipped with spectral detectors, spectral imaging has become a convenient and powerful technique for measuring GP and other membrane properties. The existing tools for spectral image processing, however, are insufficient for processing the large data sets afforded by this technological advancement, and are unsuitable for processing images acquired with rapidly internalized fluorescent probes. RESULTS Here we present a MATLAB spectral imaging toolbox with the aim of overcoming these limitations. In addition to common operations, such as the calculation of distributions of GP values, generation of pseudo-colored GP maps, and spectral analysis, a key highlight of this tool is reliable membrane segmentation for probes that are rapidly internalized. Furthermore, handling for hyperstacks, 3D reconstruction and batch processing facilitates analysis of data sets generated by time series, z-stack, and area scan microscope operations. Finally, the object size distribution is determined, which can provide insight into the mechanisms underlying changes in membrane properties and is desirable for e.g. studies involving model membranes and surfactant coated particles. Analysis is demonstrated for cell membranes, cell-derived vesicles, model membranes, and microbubbles with environmentally-sensitive probes Laurdan, carboxyl-modified Laurdan (C-Laurdan), Di-4-ANEPPDHQ, and Di-4-AN(F)EPPTEA (FE), for quantification of the local lateral density of lipids or lipid packing. CONCLUSIONS The Spectral Imaging Toolbox is a powerful tool for the segmentation and processing of large spectral imaging datasets with a reliable method for membrane segmentation and no ability in programming required. The Spectral Imaging Toolbox can be downloaded from https://uk.mathworks.com/matlabcentral/fileexchange/62617-spectral-imaging-toolbox .
Collapse
Affiliation(s)
- Miles Aron
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, OX3 7DQ UK
| | - Richard Browning
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, OX3 7DQ UK
| | - Dario Carugo
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, OX3 7DQ UK
- Faculty of Engineering and The Environment, University of Southampton, Southampton, SO17 1BJ UK
| | - Erdinc Sezgin
- MRC Human Immunology Unit, Weatherall Institute of Molecular Medicine, University of Oxford, Headley Way, Oxford, OX3 9DS UK
| | - Jorge Bernardino de la Serna
- MRC Human Immunology Unit, Weatherall Institute of Molecular Medicine, University of Oxford, Headley Way, Oxford, OX3 9DS UK
- Research Complex at Harwell, Central Laser Facility, Rutherford Appleton Laboratory, Science and Technology Facilities Council, Harwell-Oxford, OX11 0FA UK
| | - Christian Eggeling
- MRC Human Immunology Unit, Weatherall Institute of Molecular Medicine, University of Oxford, Headley Way, Oxford, OX3 9DS UK
| | - Eleanor Stride
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, OX3 7DQ UK
| |
Collapse
|
24
|
Liu HC, Li Y, Chen R, Jung H, Shung KK. Single-Beam Acoustic Trapping of Red Blood Cells and Polystyrene Microspheres in Flowing Red Blood Cell Saline and Plasma Suspensions. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:852-859. [PMID: 28236533 DOI: 10.1016/j.ultrasmedbio.2016.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 12/01/2016] [Accepted: 12/09/2016] [Indexed: 06/06/2023]
Abstract
Single-beam acoustic tweezers (SBATs) represent a new technology for particle and cell trapping. The advantages of SBATs are their deep penetration into tissues, reduction of tissue damage and ease of application to in vivo studies. The use of these tools for applications in drug delivery in vivo must meet the following conditions: large penetration depth, strong trapping force and tissue safety. A reasonable penetration depth for SBATs in the development of in vivo applications was established in a previous study conducted in water with zero velocity. However, capturing objects in flowing fluid can provide more meaningful results. In this study, we investigated the capability of SBATs to trap red blood cells (RBCs) and polystyrene microspheres in flowing RBC suspensions. Two different types of RBC suspension were prepared in this work: an RBC phosphate-buffered saline (PBS) suspension and an RBC plasma suspension. The results indicated that SBATs successfully trapped RBCs and polystyrene microspheres in a flowing RBC PBS suspension with an average steady velocity of 1.6 cm/s in a 2-mm-diameter polyimide. Furthermore, SBATs were found able to trap RBCs in a flowing RBC PBS suspension at speeds as high as 7.9 cm/s in a polyimide tube, which is higher than the velocity in capillaries (0.03 cm/s) and approaches the velocity in arterioles and venules. Moreover, the results also indicated that polystyrene microspheres can be trapped in an RBC plasma suspension, where aggregation is observed. This work represents a step forward in using this tool in actual in vivo experimentation.
Collapse
Affiliation(s)
- Hsiao-Chuan Liu
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA; Hematology and Oncology, Children's Hospital Los Angeles, Los Angeles, California, USA
| | - Ying Li
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA.
| | - Ruimin Chen
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA
| | - Hayong Jung
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA
| | - K Kirk Shung
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA.
| |
Collapse
|
25
|
Lee JY, Crake C, Teo B, Carugo D, de Saint Victor M, Seth A, Stride E. Ultrasound-Enhanced siRNA Delivery Using Magnetic Nanoparticle-Loaded Chitosan-Deoxycholic Acid Nanodroplets. Adv Healthc Mater 2017; 6. [PMID: 28195673 DOI: 10.1002/adhm.201601246] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2016] [Revised: 01/07/2017] [Indexed: 12/14/2022]
Abstract
Small interfering RNA (siRNA) has significant therapeutic potential but its clinical translation has been severely inhibited by a lack of effective delivery strategies. Previous work has demonstrated that perfluorocarbon nanodroplets loaded with magnetic nanoparticles can facilitate the intracellular delivery of a conventional chemotherapeutic drug. The aim of this study is to determine whether a similar agent can provide a means of delivering siRNA, enabling efficient transfection without degradation of the molecule. Chitosan-deoxycholic acid nanoparticles containing perfluoropentane and iron oxide (d 0 = 7.5 ± 0.35 nm) with a mean hydrodynamic diameter of 257.6 ± 10.9 nm are produced. siRNA (AllStars Hs cell death siRNA) is electrostatically bound to the particle surface and delivery to lung cancer cells and breast cancer cells is investigated with and without ultrasound exposure (500 kHz, 1 MPa peak-to-peak focal pressure, 40 cycles per burst, 1 kHz pulse repetition frequency, 10 s duration). The results show that siRNA functionality is not impaired by the treatment protocol and that the nanodroplets are able to successfully promote siRNA uptake, leading to significant apoptosis (52.4%) 72 h after ultrasound treatment.
Collapse
Affiliation(s)
- Jeong Yu Lee
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| | - Calum Crake
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| | - Boon Teo
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| | - Dario Carugo
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
- Faculty of Engineering and the Environment; Southampton University; Southampton SO17 1BJ UK
| | - Marie de Saint Victor
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| | - Anjali Seth
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| | - Eleanor Stride
- Institute of Biomedical Engineering; Department of Engineering Science; University of Oxford; Oxford, Old Road Campus OX3 7DQ UK
| |
Collapse
|
26
|
Zervantonakis IK, Arvanitis CD. Controlled Drug Release and Chemotherapy Response in a Novel Acoustofluidic 3D Tumor Platform. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2016; 12:2616-26. [PMID: 27031786 PMCID: PMC4889337 DOI: 10.1002/smll.201503342] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/02/2016] [Indexed: 05/04/2023]
Abstract
Overcoming transport barriers to delivery of therapeutic agents in tumors remains a major challenge. Focused ultrasound (FUS), in combination with modern nanomedicine drug formulations, offers the ability to maximize drug transport to tumor tissue while minimizing toxicity to normal tissue. This potential remains unfulfilled due to the limitations of current approaches in accurately assessing and quantifying how FUS modulates drug transport in solid tumors. A novel acoustofluidic platform is developed by integrating a physiologically relevant 3D microfluidic device and a FUS system with a closed-loop controller to study drug transport and assess the response of cancer cells to chemotherapy in real time using live cell microscopy. FUS-induced heating triggers local release of the chemotherapeutic agent doxorubicin from a liposomal carrier and results in higher cellular drug uptake in the FUS focal region. This differential drug uptake induces locally confined DNA damage and glioblastoma cell death in the 3D environment. The capabilities of acoustofluidics for accurate control of drug release and monitoring of localized cell response are demonstrated in a 3D in vitro tumor mode. This has important implications for developing novel strategies to deliver therapeutic agents directly to the tumor tissue while sparing healthy tissue.
Collapse
Affiliation(s)
| | - Costas D. Arvanitis
- Department of Radiology, Harvard Medical School, Brigham and Women’s Hospital 221 Longwood Ave, 514a, Boston, 02115, MA
| |
Collapse
|
27
|
Carugo D, Lee JY, Pora A, Browning RJ, Capretto L, Nastruzzi C, Stride E. Facile and cost-effective production of microscale PDMS architectures using a combined micromilling-replica moulding (μMi-REM) technique. Biomed Microdevices 2016; 18:4. [PMID: 26747434 PMCID: PMC4706591 DOI: 10.1007/s10544-015-0027-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We describe a cost-effective and simple method to fabricate PDMS-based microfluidic devices by combining micromilling with replica moulding technology. It relies on the following steps: (i) microchannels are milled in a block of acrylic; (ii) low-cost epoxy adhesive resin is poured over the milled acrylic block and allowed to cure; (iii) the solidified resin layer is peeled off the acrylic block and used as a mould for transferring the microchannel architecture onto a PDMS layer; finally (iv) the PDMS layer is plasma bonded to a glass surface. With this method, microscale architectures can be fabricated without the need for advanced technological equipment or laborious and time-consuming intermediate procedures. In this manuscript, we describe and validate the microfabrication procedure, and we illustrate its applicability to emulsion and microbubble production.
Collapse
Affiliation(s)
- Dario Carugo
- BUBBL, Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Jeong Yu Lee
- BUBBL, Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Anne Pora
- BUBBL, Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Richard J Browning
- BUBBL, Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK
| | - Lorenzo Capretto
- School of Pharmacy, University College London (UCL), London, WC1E 6BT, UK
| | - Claudio Nastruzzi
- Department of Life Sciences and Biotechnology, University of Ferrara, I-44121, Ferrara, Italy
| | - Eleanor Stride
- BUBBL, Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Oxford, OX3 7DQ, UK.
| |
Collapse
|
28
|
Lee JY, Carugo D, Crake C, Owen J, de Saint Victor M, Seth A, Coussios C, Stride E. Nanoparticle-Loaded Protein-Polymer Nanodroplets for Improved Stability and Conversion Efficiency in Ultrasound Imaging and Drug Delivery. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2015; 27:5484-92. [PMID: 26265592 DOI: 10.1002/adma.201502022] [Citation(s) in RCA: 107] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2015] [Revised: 06/23/2015] [Indexed: 05/05/2023]
Abstract
A new formulation of volatile nanodroplets stabilized by a protein and polymer coating and loaded with magnetic nanoparticles is developed. The droplets show enhanced stability and phase conversion efficiency upon ultrasound exposure compared with existing formulations. Magnetic targeting, encapsulation, and release of an anticancer drug are demonstrated in vitro with a 40% improvement in cytotoxicity compared with free drug.
Collapse
Affiliation(s)
- Jeong Yu Lee
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Dario Carugo
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Calum Crake
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Joshua Owen
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Marie de Saint Victor
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Anjali Seth
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Constantin Coussios
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, Old Road Campus Research Building, University of Oxford, Oxford, OX3 7DQ, UK
| |
Collapse
|