1
|
Paranjape VV, Henao-Guerrero N, Menciotti G, Saksena S. Volumetric evaluation of fluid responsiveness using a modified passive leg raise maneuver during experimental induction and correction of hypovolemia in anesthetized dogs. Vet Anaesth Analg 2023; 50:211-219. [PMID: 36967326 DOI: 10.1016/j.vaa.2023.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 02/10/2023] [Accepted: 02/11/2023] [Indexed: 02/22/2023]
Abstract
OBJECTIVE To demonstrate if modified passive leg raise (PLRM) maneuver can be used for volumetric evaluation of fluid responsiveness (FR) by inducing cardiac output (CO) changes during experimental induction and correction of hypovolemia in healthy anesthetized dogs. The effects of PLRM on plethysmographic variability index (PVI) and pulse pressure variation (PPV) were also investigated. STUDY DESIGN Prospective, crossover study. ANIMALS A total of six healthy anesthetized Beagle dogs. METHODS Dogs were anesthetized with propofol and isoflurane. They were mechanically ventilated under neuromuscular blockade, and normothermia was maintained. After instrumentation, all dogs were subjected to four stages: 1, baseline; 2, removal of 27 mL kg-1 circulating blood volume; 3, after blood re-transfusion; and 4, after 20 mL kg-1 hetastarch infusion over 20 minutes. A 10 minute stabilization period was allowed after induction of each stage and before data collection. At each stage, CO via pulmonary artery thermodilution, PVI, PPV and cardiopulmonary variables were measured before, during and after the PLRM maneuver. Stages were sequential, not randomized. Statistical analysis included repeated measures anova and Tukey's post hoc test, considering p < 0.05 as significant. RESULTS During stage 2, PLRM at a 30° angle significantly increased CO (mean ± standard deviation, 1.0 ± 0.1 to 1.3 ± 0.1 L minute-1; p < 0.001), with a simultaneous significant reduction in PVI (38 ± 4% to 21 ± 4%; p < 0.001) and PPV (27 ± 2% to 18 ± 2%; p < 0.001). The PLRM did not affect CO, PPV and PVI during stages 1, 3 and 4. CONCLUSIONS AND CLINICAL RELEVANCE In anesthetized dogs, PLRM at a 30° angle successfully detected FR during hypovolemia, and identified fluid nonresponsiveness during normovolemia and hypervolemia. Also, in hypovolemic dogs, significant decreases in PVI and PPV occurred in response to PLRM maneuver.
Collapse
|
2
|
Donati PA, Villalta C, Lisa T, Fravega R, Cordero IS, Tunesi M, Guevara JM, Otero PE. Echocardiographic indicators of fluid responsiveness in hospitalized dogs with compromised hemodynamics and tissue hypoperfusion. J Vet Emerg Crit Care (San Antonio) 2023; 33:22-28. [PMID: 36125168 DOI: 10.1111/vec.13255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 08/17/2021] [Accepted: 09/11/2021] [Indexed: 01/25/2023]
Abstract
OBJECTIVE To evaluate the accuracy of selected echocardiographic variables used to predict fluid responsiveness in hospitalized dogs with compromised hemodynamics and tissue hypoperfusion. DESIGN Diagnostic test study in a prospective cohort of hospitalized dogs. SETTING Veterinary referral clinics. ANIMALS Forty-four hospitalized dogs with compromised hemodynamics and tissue hypoperfusion were utilized in this study. INTERVENTIONS Echocardiographic examination before and after fluid replacement with 30 ml/kg of lactated Ringer's solution. MEASUREMENTS AND MAIN RESULTS Pre-fluid replacement measurements of velocity of transmitral E wave (E-peak), the left ventricular end-diastolic internal diameter normalized to body weight (LVIDdN), and the left ventricular end-systolic internal diameter normalized to body weight (LVIDsN) were significantly lower in fluid-responsive patients compared with nonresponders (P < 0.001). The area under the receiver operating characteristic curve (AUROC) with its 95% confidence interval (CI) for each significant predictor was as follows: E-peak 0.907 (0.776-1.000, P < 0.001) and LVIDdN 0.919 (0.801-1.000, P < 0.001). The predictive capacity of LVIDsN was not significantly better than chance (AUROC, 0.753; 95% CI, 0.472-1.000, P = 0.078). A significant negative linear correlation was observed between the percentage of increase in velocity-time integral after expansion and the echocardiographic variables LVIDdN (rs = -0.452, P = 0.023) and E-peak (rs = -0.396, P = 0.008) pre-fluid replacement. The intraobserver and interobserver variability was very low (<5 %) for all measurements. CONCLUSIONS In this study using critically ill dogs with compromised hemodynamics and tissue hypoperfusion, pre-fluid replacement measurements of LVIDdN and E-peak adequately predict fluid responsiveness. Because a small number of fluid nonresponders were involved in the present study (11.4%), further studies that include larger numbers of fluid-nonresponsive animals are required.
Collapse
Affiliation(s)
- Pablo A Donati
- Facultad de Ciencias Veterinarias, Cátedra de Anestesiología y Algiología, Universidad de Buenos Aires, Buenos Aires, Argentina.,Cooperative Veterinary Intensive Care Unit (UCICOOP), Buenos Aires, Argentina
| | | | - Tarragona Lisa
- Facultad de Ciencias Veterinarias, Cátedra de Anestesiología y Algiología, Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Rodrigo Fravega
- Internal Medicine Service, Hospital Veterinario de Santiago, Santiago, Chile
| | | | - Marcela Tunesi
- Cooperative Veterinary Intensive Care Unit (UCICOOP), Buenos Aires, Argentina
| | - Juan Manuel Guevara
- Cooperative Veterinary Intensive Care Unit (UCICOOP), Buenos Aires, Argentina
| | - Pablo E Otero
- Facultad de Ciencias Veterinarias, Cátedra de Anestesiología y Algiología, Universidad de Buenos Aires, Buenos Aires, Argentina
| |
Collapse
|
3
|
Henze IS, Hilpert L, Kutter APN. Development and comparison of an esophageal Doppler monitoring-based treatment algorithm with a heart rate and blood pressure-based treatment algorithm for goal-directed fluid therapy in anesthetized dogs: A pilot study. Front Vet Sci 2022; 9:1008240. [PMID: 36262533 PMCID: PMC9574010 DOI: 10.3389/fvets.2022.1008240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 09/16/2022] [Indexed: 11/04/2022] Open
Abstract
The objective of this pilot study was to determine the feasibility of a study comparing the efficacy of an esophageal Doppler monitor (EDM)-based fluid therapy algorithm with a heart rate (HR)- and mean arterial blood pressure (MAP)-based algorithm in reducing hypotension and fluid load in anesthetized dogs. Client-owned dogs undergoing general anesthesia for surgical procedures were randomized to two groups. An EDM probe for monitoring blood flow in the descending aorta was placed in each dog before receiving a crystalloid bolus (5 mL/kg) over 5 min. Fluids were repeated in case of fluid responsiveness defined by increasing Velocity Time Integral (VTI) ≥ 10% in group EDM and by decreasing HR ≥ 5 beats/min and/or increasing MAP ≥ 3 mmHg in group standard. The feasibility outcomes included the proportion of dogs completing the study and the clinical applicability of the algorithms. The clinical outcomes were the total administered fluid volume and the duration of hypotension defined as MAP < 60 mmHg. Data was compared between groups with Mann-Whitney U-test. p < 0.05 were deemed significant. Of 25 dogs screened, 14 completed the study (56%). There were no differences in the proportion of recorded time spent in hypotension in group standard [2 (0–39)% (median (range))] and EDM [0 (0–63) %, p = 1], or the total volume of fluids [standard 8 (5–14) mL/kg/h, EDM 11 (4–20) mL/kg/h, p = 0.3]. This study declined the feasibility of a study comparing the impact of two newly developed fluid therapy algorithms on hypotension and fluid load in their current form. Clinical outcome analyses were underpowered and no differences in treatment efficacy between the groups could be determined. The conclusions drawn from this pilot study provide important information for future study designs.
Collapse
|
4
|
Zhang H, Yuan H, Yu H, Zhang Y, Feng S. Correlation between pleth variability index and ultrasonic inferior vena cava-collapsibility index in parturients with twin pregnancies undergoing cesarean section under spinal anesthesia. Eur J Med Res 2022; 27:139. [PMID: 35933431 PMCID: PMC9356457 DOI: 10.1186/s40001-022-00771-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 07/26/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND To explore the correlation and consistency of non-invasive pleth variability index (PVI) combined with ultrasonic measurement of inferior vena cava-collapsibility index (IVC-CI) in parturients with twin pregnancies undergoing cesarean section under spinal anesthesia. METHODS Forty-seven twin pregnancies women undergoing elective cesarean section were selected. The ASA score was rated as I-II, aged from 18 to 45 years. Spinal anesthesia was performed at L3-4. PVI and IVC-CI, general data (BMI, gestational weeks, operation duration, blood loss), MAP, temperature sensory block level and adverse reactions were recorded at baseline (T1) and completion of testing the level of spinal anesthesia (T2). RESULTS The correlation coefficient analysis of baseline IVC-CI% and PVI revealed that the Pearson's coefficient was 0.927, > 0.4. Thus, pre-anesthesia IVC-CI% had a strong correlation with PVI, with R2 of 85.69%. The correlation coefficient analysis of post-anesthesia IVC-CI% and PVI revealed that the Pearson's coefficient was 0.904, > 0.4. Thus, post-anesthesia IVC-CI% had a strong correlation with PVI, with R2 of 81.26%. CONCLUSION PVI is strongly consistent with ultrasound measurement of IVC-CI twin pregnancies, which can be used as a valuable index for predicting the volume in parturients with twin pregnancies undergoing cesarean section under spinal anesthesia. Trial registration This study was registered on ClinicalTrials.gov with clinical trial registration number of ChiCTR2200055364 (08/01/2022).
Collapse
Affiliation(s)
- Huiying Zhang
- Department of Anesthesiology, Women’s Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, No. 123 Tianfei Xiang, Mochou Road, Jiangsu 210004 Nanjing, People’s Republic of China
| | - Hongmei Yuan
- Department of Anesthesiology, Women’s Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, No. 123 Tianfei Xiang, Mochou Road, Jiangsu 210004 Nanjing, People’s Republic of China
| | - Huiling Yu
- Department of Anesthesiology, Women’s Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, No. 123 Tianfei Xiang, Mochou Road, Nanjing, Jiangsu 210004 People’s Republic of China
| | - Yue Zhang
- Department of Anesthesiology, Women’s Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, No. 123 Tianfei Xiang, Mochou Road, Nanjing, Jiangsu 210004 People’s Republic of China
| | - Shanwu Feng
- Department of Anesthesiology, Women’s Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, No. 123 Tianfei Xiang, Mochou Road, Nanjing, Jiangsu 210004 People’s Republic of China
| |
Collapse
|
5
|
Kim D, Son WG, Shin D, Kim J, Lee I. Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs. J Vet Sci 2022; 23:e68. [PMID: 36038189 PMCID: PMC9715388 DOI: 10.4142/jvs.22090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 07/08/2022] [Accepted: 07/13/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. OBJECTIVES This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. METHODS Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. RESULTS The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). CONCLUSIONS The PPV is a dynamic parameter that can predict a dog's hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.
Collapse
Affiliation(s)
- Dalhae Kim
- Department of Veterinary Clinical Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea
| | - Won-Gyun Son
- Department of Veterinary Clinical Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea
| | - Donghwi Shin
- Department of Veterinary Clinical Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea
| | - Jiyoung Kim
- Department of Veterinary Clinical Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea
| | - Inhyung Lee
- Department of Veterinary Clinical Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea
| |
Collapse
|
6
|
Martín Bellido V, Monticelli P, Vettorato E. Anaesthetic management of a cat with diabetes mellitus undergoing glucagonoma excision. VETERINARY RECORD CASE REPORTS 2022. [DOI: 10.1002/vrc2.328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
7
|
Viilmann I, Vettorato E. Propofol‐dexmedetomidine continuous infusion in a dog with pulmonic stenosis undergoing balloon valvuloplasty. VETERINARY RECORD CASE REPORTS 2022. [DOI: 10.1002/vrc2.291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Inga Viilmann
- Dick White Referrals Six Mile Bottom Cambridgeshire UK
| | | |
Collapse
|
8
|
Sambugaro B, De Gennaro C, Vettorato E. Anaesthetic management and complications during cutting balloon and high‐pressure balloon dilation in a dog with a double‐chambered right ventricle. VETERINARY RECORD CASE REPORTS 2021. [DOI: 10.1002/vrc2.264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
9
|
Zeiler GE, Dzikiti BT, Kamerman P, Pohlin F, Buck RK, Fuller A. Investigation of biomarkers for impending fluid overload in a feline acute haemorrhage-resuscitation model. Vet Anaesth Analg 2021; 48:871-881. [PMID: 34598894 DOI: 10.1016/j.vaa.2021.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 02/14/2021] [Accepted: 04/19/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To determine biomarkers for impending fluid overload during intravenous fluid administration in a feline haemorrhage-resuscitation model. STUDY DESIGN Randomized crossover study. ANIMALS A group of six domestic cats (mean age and weight: 21 months; 4.9 kg, respectively). METHODS The cats underwent three treatments, 2 months apart. They were anaesthetized and instrumented to measure a range of physiological, blood gas, haematological and biochemical variables over time. Samples were taken during a health check, before haemorrhage, after haemorrhage and then at 30 minute intervals during fluid resuscitation and 24 hours later. The three treatments were: 1) control, sham haemorrhage and resuscitation; 2) lactated Ringer's solution (LRS); and 3) 6% tetrastarch 130/0.4 (Vol) where the cats underwent a controlled haemorrhage then resuscitation by administering LRS and Vol at 60 and 20 mL kg-1 hour-1, respectively, for 120 minutes. Fluid overload was identified by nasal discharge and radiographic evidence. Biomarkers were variables that exceeded the reference interval for cats during treatment. Potential biomarkers were analysed using receiver operating characteristic curves (p < 0.05). RESULTS Mean ± standard deviation total blood loss was 10.2 ± 2.3, 29.3 ± 9.0 and 29.1 ± 6.3 mL kg-1 for control, LRS and Vol, respectively. The total volume of LRS and Vol administered was 120 and 40 mL kg-1, respectively. Haematocrit, albumin, magnesium, chloride-to-sodium ratio and sodium-chloride difference were identified as potential biomarkers. These variables exceeded the reference intervals from 30 minutes of resuscitation onwards. A chloride-to-sodium ratio > 0.84 was the most sensitive (90%) and specific (75%) of all potential biomarkers. CONCLUSIONS AND CLINICAL RELEVANCE Changes in physiological variables, haematocrit and albumin were poor biomarkers of impending fluid overload compared with electrolytes. Finding the ideal biomarker to identify impending fluid overload of commonly used intravenous fluids should improve the safety of their administration in cats.
Collapse
Affiliation(s)
- Gareth E Zeiler
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa; Section of Anaesthesia and Critical Care, Valley Farm Animal Hospital, Pretoria, South Africa; Brain Function Research Group, School of Physiology, University of the Witwatersrand, Johannesburg, South Africa.
| | - Brighton T Dzikiti
- Clinical Sciences Department, Ross University School of Veterinary Medicine, Basseterre, St. Kitts and Nevis
| | - Peter Kamerman
- Brain Function Research Group, School of Physiology, University of the Witwatersrand, Johannesburg, South Africa
| | - Friederike Pohlin
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa; Section of Anaesthesia and Critical Care, Valley Farm Animal Hospital, Pretoria, South Africa
| | - Roxanne K Buck
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa
| | - Andrea Fuller
- Brain Function Research Group, School of Physiology, University of the Witwatersrand, Johannesburg, South Africa
| |
Collapse
|
10
|
Teixeira-Neto FJ, Valverde A. Clinical Application of the Fluid Challenge Approach in Goal-Directed Fluid Therapy: What Can We Learn From Human Studies? Front Vet Sci 2021; 8:701377. [PMID: 34414228 PMCID: PMC8368984 DOI: 10.3389/fvets.2021.701377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 07/06/2021] [Indexed: 11/13/2022] Open
Abstract
Resuscitative fluid therapy aims to increase stroke volume (SV) and cardiac output (CO) and restore/improve tissue oxygen delivery in patients with circulatory failure. In individualized goal-directed fluid therapy (GDFT), fluids are titrated based on the assessment of responsiveness status (i.e., the ability of an individual to increase SV and CO in response to volume expansion). Fluid administration may increase venous return, SV and CO, but these effects may not be predictable in the clinical setting. The fluid challenge (FC) approach, which consists on the intravenous administration of small aliquots of fluids, over a relatively short period of time, to test if a patient has a preload reserve (i.e., the relative position on the Frank-Starling curve), has been used to guide fluid administration in critically ill humans. In responders to volume expansion (defined as individuals where SV or CO increases ≥10–15% from pre FC values), FC administration is repeated until the individual no longer presents a preload reserve (i.e., until increases in SV or CO are <10–15% from values preceding each FC) or until other signs of shock are resolved (e.g., hypotension). Even with the most recent technological developments, reliable and practical measurement of the response variable (SV or CO changes induced by a FC) has posed a challenge in GDFT. Among the methods used to evaluate fluid responsiveness in the human medical field, measurement of aortic flow velocity time integral by point-of-care echocardiography has been implemented as a surrogate of SV changes induced by a FC and seems a promising non-invasive tool to guide FC administration in animals with signs of circulatory failure. This narrative review discusses the development of GDFT based on the FC approach and the response variables used to assess fluid responsiveness status in humans and animals, aiming to open new perspectives on the application of this concept to the veterinary field.
Collapse
Affiliation(s)
- Francisco José Teixeira-Neto
- Departmento de Cirurgia Veterinária e Reprodução Animal, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Botucatu, Brazil
| | - Alexander Valverde
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada
| |
Collapse
|
11
|
Viilmann I, Vettorato E. Perioperative use of thoracic epidural anaesthesia, dexmedetomidine and magnesium sulphate infusion in a dog undergoing neuroendocrine tumour resection. VETERINARY RECORD CASE REPORTS 2021. [DOI: 10.1002/vrc2.177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
12
|
Boysen SR, Gommeren K. Assessment of Volume Status and Fluid Responsiveness in Small Animals. Front Vet Sci 2021; 8:630643. [PMID: 34124213 PMCID: PMC8193042 DOI: 10.3389/fvets.2021.630643] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 04/29/2021] [Indexed: 12/30/2022] Open
Abstract
Intravenous fluids are an essential component of shock management in human and veterinary emergency and critical care to increase cardiac output and improve tissue perfusion. Unfortunately, there are very few evidence-based guidelines to help direct fluid therapy in the clinical setting. Giving insufficient fluids and/or administering fluids too slowly to hypotensive patients with hypovolemia can contribute to continued hypoperfusion and increased morbidity and mortality. Similarly, giving excessive fluids to a volume unresponsive patient can contribute to volume overload and can equally increase morbidity and mortality. Therefore, assessing a patient's volume status and fluid responsiveness, and monitoring patient's response to fluid administration is critical in maintaining the balance between meeting a patient's fluid needs vs. contributing to complications of volume overload. This article will focus on the physiology behind fluid responsiveness and the methodologies used to estimate volume status and fluid responsiveness in the clinical setting.
Collapse
Affiliation(s)
- Søren R. Boysen
- Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Kris Gommeren
- Department of Companion Animals, Faculty of Veterinary Medicine, University of Liège, Liège, Belgium
| |
Collapse
|
13
|
Chalifoux NV, Hess RS, Silverstein DC. Effectiveness of intravenous fluid resuscitation in hypotensive cats: 82 cases (2012-2019). J Vet Emerg Crit Care (San Antonio) 2021; 31:508-515. [PMID: 34014600 DOI: 10.1111/vec.13075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/15/2019] [Accepted: 11/20/2019] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the effectiveness of intravenous fluid resuscitation in hypotensive cats in an emergency room setting. Secondary objectives were to investigate changes in heart rate (HR) and body temperature (BT) in response to fluid resuscitation, and the association of these changes with patient survival. DESIGN Retrospective study. SETTING University teaching hospital. ANIMALS Eighty-two cats with confirmed hypotension. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Medical records from 2012 to 2019 were searched for cats that had documented systemic arterial hypotension (blood pressure measured using a Doppler ultrasonic flow probe [DBP] < 90 mm Hg) on presentation to the emergency room. Data collected included patient characteristics and DBP, HR, and BT before and after fluid resuscitation, type and volume of fluids administered, and outcome. The median DBP before and after resuscitative fluid therapy in all cats was 65 mm Hg (range, 20-85 mm Hg) and 80 mm Hg (range, 20-128 mm Hg), respectively (P < 0.001). However, only 30 cats (37%) were classified as responders to fluid resuscitation (DBP ≥ 90 mm Hg following bolus therapy). The mean HR and median BT before resuscitative fluid therapy was 159/min and 36.7°C. Following fluid resuscitation, where measured, the mean HR and median BT was 154/min (P = 1.00) and 35.9°C (P = 1.00). No significant differences in HR and BT were identified between responders and non-responders. Cats had a low survival rate of 7%. All survivors (n = 5) were initially bradycardic (HR < 160/min), compared to only 45% of non-survivors (P = 0.4). CONCLUSIONS Bolus fluid resuscitation effectively increases blood pressure in hypotensive cats; however, it does not result in normalization of blood pressure, HR, or BT in the majority of cases.
Collapse
Affiliation(s)
- Nolan V Chalifoux
- Department of Clinical Sciences & Advanced Medicine, University of Pennsylvania, School of Veterinary Medicine, Philadelphia, Pennsylvania, USA
| | - Rebecka S Hess
- Department of Clinical Sciences & Advanced Medicine, University of Pennsylvania, School of Veterinary Medicine, Philadelphia, Pennsylvania, USA
| | - Deborah C Silverstein
- Department of Clinical Sciences & Advanced Medicine, University of Pennsylvania, School of Veterinary Medicine, Philadelphia, Pennsylvania, USA
| |
Collapse
|
14
|
Intraoperative Assessment of Fluid Responsiveness in Normotensive Dogs under Isoflurane Anaesthesia. Vet Sci 2021; 8:vetsci8020026. [PMID: 33670144 PMCID: PMC7916826 DOI: 10.3390/vetsci8020026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/31/2021] [Accepted: 02/07/2021] [Indexed: 12/17/2022] Open
Abstract
The aim of this study was to evaluate the incidence of fluid responsiveness (FR) to a fluid challenge (FC) in normotensive dogs under anaesthesia. The accuracy of pulse pressure variation (PPV), systolic pressure variation (SPV), stroke volume variation (SVV), and plethysmographic variability index (PVI) for predicting FR was also evaluated. Dogs were anaesthetised with methadone, propofol, and inhaled isoflurane in oxygen, under volume-controlled mechanical ventilation. FC was performed by the administration of 5 mL/kg of Ringer's lactate within 5 min. Cardiac index (CI; L/min/m2), PPV, (%), SVV (%), SPV (%), and PVI (%) were registered before and after FC. Data were analysed with ANOVA and ROC tests (p < 0.05). Fluid responsiveness was defined as 15% increase in CI. Eighty dogs completed the study. Fifty (62.5%) were responders and 30 (37.5%) were nonresponders. The PPV, PVI, SPV, and SVV cut-off values (AUC, p) for discriminating responders from nonresponders were PPV >13.8% (0.979, <0.001), PVI >14% (0.956, <0.001), SPV >4.1% (0.793, <0.001), and SVV >14.7% (0.729, <0.001), respectively. Up to 62.5% of normotensive dogs under inhalant anaesthesia may be fluid responders. PPV and PVI have better diagnostic accuracy to predict FR, compared to SPV and SVV.
Collapse
|
15
|
Medina‐Serra R, Palacios C, McMillan M. Alternative anaesthetic management in a reintervention for correction of a left‐to‐right shunting patent ductus arteriosus (PDA) in a dog. VETERINARY RECORD CASE REPORTS 2021. [DOI: 10.1002/vrc2.25] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Roger Medina‐Serra
- Royal Veterinary College Department of Veterinary, Clinical Sciences Anaesthesia and Analgesia Hatfield UK
| | | | - Matthew McMillan
- Royal Veterinary College Queen Mother Hosptial for Animals Hatfield UK
| |
Collapse
|
16
|
Sasaki K, Yamamoto S, Mutoh T. Noninvasive assessment of fluid responsiveness for emergency abdominal surgery in dogs with pulmonary hypertension: Insights into high-risk companion animal anesthesia. PLoS One 2020; 15:e0241234. [PMID: 33095826 PMCID: PMC7584187 DOI: 10.1371/journal.pone.0241234] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 10/11/2020] [Indexed: 11/19/2022] Open
Abstract
Objective Optimizing cardiac stroke volume during high-risk surgical anesthesia is of particular interest with regard to a therapeutic target to reduce the incidence of postoperative complications. However, intensive fluid management in critically ill small animals with pulmonary hypertension (PH) has been empirically performed, and thus it can be challenging. Stroke volume variation (SVV) has been used as a dynamic preload predictor of fluid responsiveness. We hypothesized that if SVV exhibited robust reliability in the setting of hemodynamically unstable condition, it would provide more precise information on fluid resuscitation to translate it into veterinary anesthesia. Thus the aim of this study was to investigate the utility of SVV measured by the electrical velocimetry (EV) method for predicting fluid responsiveness in dogs with PH. Methods Sixteen dogs undergoing emergency abdominal surgery and diagnosed with PH secondary to myxomatous mitral valve disease (MMVD) on preoperative transthoracic echocardiogram were included. Dogs were randomly assigned to 2 groups with and without inotropic cardiac support with dobutamine. Hemodynamic measurements including stroke volume and SVV derived from the EV device were performed under general anesthesia before (baseline) and after surgery (fluid challenge with a colloid solution defined by a SV increase of ≥ 10%). Results In both groups, SVV elevated significantly after abdominal surgery compared with baseline. In dobutamine infused group, the SVV values decreased significantly after fluid challenge (P < 0.05) with a greater number of responders than saline infused control group (P < 0.01). Receiver operating curve analysis of SVV confirmed high positive predictive value for dogs during dobutamine infusion (P < 0.05; cut-off value of 15%; specificity 90%, sensitivity 82%). Conclusions Noninvasive EV monitoring may be useful for the prediction of fluid responsiveness in critically ill dogs with left-sided heart failure-related PH. This normalization of dynamic preload indices, which could be achieved more precisely under inotropic support, may prevent further detrimental consequence of fluid loading.
Collapse
Affiliation(s)
- Kazumasu Sasaki
- Small Animal Emergency and Critical Care Service, Sendai Animal Care and Research Center, Sendai, Japan
- Akita Cerebrospinal and Cardiovascular Center, Akita, Japan
| | - Shuzo Yamamoto
- Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan
| | - Tatsushi Mutoh
- Small Animal Emergency and Critical Care Service, Sendai Animal Care and Research Center, Sendai, Japan
- Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan
- * E-mail:
| |
Collapse
|
17
|
Donati PA, Guevara JM, Ardiles V, Guillemi EC, Londoño L, Dubin A. Caudal vena cava collapsibility index as a tool to predict fluid responsiveness in dogs. J Vet Emerg Crit Care (San Antonio) 2020; 30:677-686. [PMID: 33063922 DOI: 10.1111/vec.13009] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 02/03/2019] [Accepted: 03/09/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVE To evaluate the use of the caudal vena cava collapsibility index (CVCCI) as a predictor of fluid responsiveness in hospitalized, critically ill dogs with hemodynamic or tissue perfusion abnormalities. DESIGN Retrospective observational study. SETTING Private referral center. ANIMALS Twenty-seven critically ill, spontaneously breathing dogs with compromised hemodynamics or tissue hypoperfusion. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS The electronic medical records were searched for dogs admitted for any cause, from August 2016 to December 2017. We included dogs with ultrasound measurements of: CVCCI, performed at baseline; and velocity time integral (VTI) of the subaortic blood flow, carried out before and after a fluid load. CVCCI was estimated as: (maximum diameter-minimum diameter/maximum diameter) × 100. Dogs in which VTI increased ≥15% were considered fluid responders. The CVCCI accurately predicted fluid responsiveness with an area under the receiver operating characteristic curve of 0.96 (95% CI, 0.88 to 1.00). The optimal cut-off of CVCCI that better discriminated between fluid responders and nonresponders was 27%, with 100.0% sensitivity and 83.3% specificity. At baseline, fluid responders had lower VTI (5.48 [4.26 to 7.40] vs 10.61 [7.38 to 13.23] cm, P = 0.004) than nonresponders. The basal maximum diameter of the caudal vena cava adjusted to body weight was not different between responders and nonresponders (0.050 [0.030 to 0.100] vs 0.079 [0.067 to 0.140] cm/kg, P = 0.339). The increase in VTI was related to basal CVCCI (R = 0.60, P = 0.001). Bland-Altman analysis showed narrow 95% limits of agreement between measurements of CVCCI and VTI performed by different observers or by the same observer. CONCLUSIONS The results of this small cohort study suggest that CVCCI can accurately predict fluid responsiveness in critically ill dogs with perfusion abnormalities. Further research is necessary to extrapolate these results to larger populations of hospitalized dogs.
Collapse
Affiliation(s)
- Pablo A Donati
- Cooperative Veterinary Intensive Care Unit, Buenos Aires, Argentina
| | - Juan M Guevara
- Cooperative Veterinary Intensive Care Unit, Buenos Aires, Argentina
| | - Victoria Ardiles
- General Surgery Service, Surgery Department, Non-sponsored Research Area, Research Department, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | | | - Leonel Londoño
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida
| | - Arnaldo Dubin
- Chair of Applied Pharmacology, Faculty of Medical Sciences, National University of La Plata, La Plata, Argentina
| |
Collapse
|
18
|
Wang X, Jiang L, Liu S, Ge Y, Gao J. Value of respiratory variation of aortic peak velocity in predicting children receiving mechanical ventilation: a systematic review and meta-analysis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2019; 23:372. [PMID: 31757222 PMCID: PMC6874822 DOI: 10.1186/s13054-019-2647-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Accepted: 10/09/2019] [Indexed: 12/27/2022]
Abstract
Background Accurate volume assessment is crucial in children under fluid therapy. Over the last decade, respiratory variation of aortic peak velocity (△VPeak) has been applied in intensive care unit and surgeries to help clinicians guide fluid management. The aim of this systematic review and meta-analysis was to test diagnostic performance of △VPeak in predicting fluid responsiveness of ventilated children and to explore the potential factors that influence the accuracy of △VPeak. Methods We searched PubMed, Embase, and Cochrane from inception to April 2019 that evaluated association between △VPeak and fluid responsiveness after fluid challenge in children receiving mechanical ventilation. Data synthesis was performed within the bivariate mixed-effects regression model modified for synthesis of diagnostic test data. Results Eleven studies with a total of 302 pediatric patients were included in our meta-analysis. The pooled sensitivity and specificity of △VPeak was 0.89 (95%CI = 0.77 to 0.95) and 0.85 (95%CI = 0.77 to 0.91), respectively. The diagnostic odds ratio (DOR) of △VPeak was 48 (95%CI = 15 to 155). SROC yielded an area under the curve of 0.91 (95%CI = 0.88–0.93). The △VPeak cutoff value was nearly conically symmetrical distribution and varied from 7 to 20%. After excluding several extreme studies, most data were centered between 12 and 13%. The medium and mean cutoff values of △VPeak were 12.2% and 12.7%, respectively. In subgroup analysis, compared to total data analysis, △VPeak performed weaker in the younger children group (mean ages < 25 months), with lower area under the summary receiver operating characteristic curve (AUSROC) of 0.80 (0.76 to 0.83), but stronger in the older children group (mean ages > 25 months), with AUSROC of 0.96 (0.94 to 0.97). Conclusions Overall, △VPeak has a good ability in predicting fluid responsiveness of children receiving mechanical ventilation, but this ability decreases in younger children (mean age < 25 months). The optimal threshold of △VPeak to predict fluid responsiveness in ventilated children is reliable between 12 and 13%. Trial registration The study protocol was registered prospectively on PROSPERO no. CRD42019129361.
Collapse
Affiliation(s)
- Xiaoying Wang
- Department of Anesthesiology, Clinical Medical College of Yangzhou University (Northern Jiangsu People's Hospital), Yangzhou, 225001, China.
| | - Lulu Jiang
- Department of Anesthesiology, The Second Xiangya Hospital of Central South University, Changsha, 410011, Hunan, China
| | - Shuai Liu
- Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Yali Ge
- Department of Anesthesiology, Clinical Medical College of Yangzhou University (Northern Jiangsu People's Hospital), Yangzhou, 225001, China
| | - Ju Gao
- Department of Anesthesiology, Clinical Medical College of Yangzhou University (Northern Jiangsu People's Hospital), Yangzhou, 225001, China.
| |
Collapse
|
19
|
Araos J, Kenny JES, Rousseau-Blass F, Pang DS. Dynamic prediction of fluid responsiveness during positive pressure ventilation: a review of the physiology underlying heart-lung interactions and a critical interpretation. Vet Anaesth Analg 2019; 47:3-14. [PMID: 31831334 DOI: 10.1016/j.vaa.2019.08.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 07/10/2019] [Accepted: 08/17/2019] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Cardiovascular responses to hypovolemia and hypotension are depressed during general anesthesia. A considerable number of anesthetized and critically ill animals may not benefit hemodynamically from a fluid bolus; therefore, it is important to have measures for accurate prediction of fluid responsiveness. Static measures of preload, such as central venous pressure, do not provide accurate prediction of fluid responsiveness, whereas dynamic measures of cardiovascular function, obtained during positive pressure ventilation, are highly predictive. This review describes key physiological concepts behind heart-lung interactions during positive pressure ventilation, factors that can modify this relationship and provides the basis for a rational interpretation of the information obtained from dynamic measurements, with a focus on pulse pressure variation (PPV). DATABASE USED PubMed. Search items used were: heart-lung interaction, positive pressure ventilation, pulse pressure variation, dynamic index of fluid therapy, goal-directed hemodynamic therapy, dogs, cats, pigs, horses and rabbits. CONCLUSIONS The veterinary literature suggests that targeting specific PPV thresholds should guide fluid therapy in lieu of conventional assessments. Understanding the physiology of heart-lung interactions during intermittent positive pressure ventilation provides a rational basis for interpreting the literature on dynamic indices of fluid responsiveness, including PPV. Clinical trials are needed to evaluate whether goal-directed fluid therapy based on PPV results in improved outcomes in veterinary patient populations.
Collapse
Affiliation(s)
- Joaquin Araos
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, USA.
| | | | - Frederik Rousseau-Blass
- Centre Hospitalier Universitaire Veterinaire, Faculte de Medecine Veterinaire, Universite de Montreal, Saint-Hyacinthe, QC, Canada
| | - Daniel Sj Pang
- Centre Hospitalier Universitaire Veterinaire, Faculte de Medecine Veterinaire, Universite de Montreal, Saint-Hyacinthe, QC, Canada; Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, AB, Canada
| |
Collapse
|
20
|
Di Bella C, Lacitignola L, Fracassi L, Skouropoulou D, Crovace A, Staffieri F. Pulse Pressure Variation Can Predict the Hemodynamic Response to Pneumoperitoneum in Dogs: A Retrospective Study. Vet Sci 2019; 6:vetsci6010017. [PMID: 30791578 PMCID: PMC6466147 DOI: 10.3390/vetsci6010017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 02/07/2019] [Accepted: 02/15/2019] [Indexed: 11/25/2022] Open
Abstract
Pneumoperitoneum may induce important hemodynamic alterations in healthy subjects. Pulse pressure variation (PPV) is a hemodynamic parameter able to discriminate preload dependent subjects. Anesthesia records of dogs undergoing laparoscopy were retrospectively evaluated. The anesthetic protocol included acepromazine, methadone, propofol and isoflurane administered with oxygen under mechanical ventilation. The hemodynamic parameters were considered five minutes before (BASE) and ten minutes after (P10) the pneumoperitoneum. Based on the cardiac index (CI) variation, at P10, dogs were classified as sensitive (S group, CI ≤ 15%) and non-sensitive (NO-S group). Data were analyzed with the ANOVA test and the ROC curve (p < 0.05). Fifty-five percent of dogs (S) had a reduction of CI ≥ 15% at P10 (2.97 ± 1.4 L/min/m2) compared to BASE (4.32 ± 1.62 L/min/m2) and at P10 in the NO-S group (4.51 ± 1.41 L/min/m2). PPV at BASE was significantly higher in the S group (22.4% ± 6.1%) compared to the NO-S group (10.9% ± 3.3%). The ROC curve showed a threshold of PPV > 16% to distinguish the S and NO-S groups. PPV may be a valid predictor of the hemodynamic response to pneumoperitoneum in dogs. A PPV > 16% can identify patients that may require fluid administration before the creation of pneumoperitoneum.
Collapse
Affiliation(s)
- Caterina Di Bella
- PhD Course in Tissues and Organs Transplantation and Cellular Therapies, Department of Emergency and Organ Transplantation, University of Bari, 70010 Bari, Italy.
| | - Luca Lacitignola
- Department of Emergency and Organ Transplantation, Section of Veterinary Clinics and Animal Production; University of Bari, 70010 Bari, Italy.
| | - Laura Fracassi
- PhD Course in Tissues and Organs Transplantation and Cellular Therapies, Department of Emergency and Organ Transplantation, University of Bari, 70010 Bari, Italy.
| | - Despoina Skouropoulou
- PhD Course in Tissues and Organs Transplantation and Cellular Therapies, Department of Emergency and Organ Transplantation, University of Bari, 70010 Bari, Italy.
| | - Antonio Crovace
- Department of Emergency and Organ Transplantation, Section of Veterinary Clinics and Animal Production; University of Bari, 70010 Bari, Italy.
| | - Francesco Staffieri
- Department of Emergency and Organ Transplantation, Section of Veterinary Clinics and Animal Production; University of Bari, 70010 Bari, Italy.
| |
Collapse
|
21
|
Celeita-Rodríguez N, Teixeira-Neto FJ, Garofalo NA, Dalmagro TL, Girotto CH, Oliveira GCV, Santos IF. Comparison of the diagnostic accuracy of dynamic and static preload indexes to predict fluid responsiveness in mechanically ventilated, isoflurane anesthetized dogs. Vet Anaesth Analg 2019; 46:276-288. [PMID: 30979542 DOI: 10.1016/j.vaa.2018.12.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 12/03/2018] [Accepted: 12/12/2018] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To compare the diagnostic accuracy of pulse pressure variation (PPV), stroke volume variation from pulse contour analysis (SVVPCA), plethysmographic variability index (PVI), central venous pressure (CVP) and global end-diastolic volume index measured by transpulmonary thermodilution (GEDVITPTD) to predict fluid responsiveness (FR) in dogs. STUDY DESIGN Prospective study. ANIMALS A group of 40 bitches (13.8-26.8 kg) undergoing ovariohysterectomy. METHODS Anesthesia was maintained with isoflurane under volume-controlled ventilation (tidal volume 12 mL kg-1; inspiratory pause during 40% of inspiratory time; inspiration:expiration ratio 1:1.5). Transpulmonary thermodilution cardiac output was recorded through a femoral artery catheter. FR was evaluated by a fluid challenge (lactated Ringer's, 20 mL kg-1 over 15 minutes) administered once (n = 21) or twice (n = 18) before surgery. Individuals were responders if stroke volume index measured by transpulmonary thermodilution increased >15% after the last fluid challenge. RESULTS Of the 39 animals studied, 21 were responders and 18 were nonresponders. Area under the receiver operating characteristics curve (AUROC) was 0.976, 0.906, 0.868 and 0.821 for PPV, PVI, CVP and SVVPCA, respectively (p < 0.0001 from AUROC = 0.5). GEDVITPTD failed to predict FR (AUROC: 0.660, p = 0.078). Best cut-off thresholds discriminating responders and nonresponders, with respective zones of diagnostic uncertainty (gray zones) were: PPV >16% (15-16%), PVI >11% (10-13%), SVVPCA >10% (9-18%) and CVP ≤1 mmHg (0-3 mmHg). Percentage of animals within gray zone limits was 13% (PPV), 28% (PVI), 51% (SVVPCA) and 67% (CVP). CONCLUSIONS AND CLINICAL RELEVANCE PPV has better diagnostic accuracy to predict FR (conclusive results in nearly 90% of population) than other preload indexes in healthy dogs. When invasive blood pressure is unavailable, PVI will predict FR with reasonable accuracy (conclusive results in approximately 70% of the population). PPV and PVI values above gray zone limits (>16% and >13%, respectively) can reliably predict responders to volume expansion.
Collapse
Affiliation(s)
| | - Francisco J Teixeira-Neto
- Faculdade de Medicina, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil; Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil.
| | - Natache A Garofalo
- Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil
| | - Tábata L Dalmagro
- Faculdade de Medicina, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil
| | - Carolina H Girotto
- Faculdade de Medicina, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil
| | | | - Ivan Fc Santos
- Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista (UNESP), Botucatu, SP, Brazil
| |
Collapse
|
22
|
Noel-Morgan J, Muir WW. Anesthesia-Associated Relative Hypovolemia: Mechanisms, Monitoring, and Treatment Considerations. Front Vet Sci 2018; 5:53. [PMID: 29616230 PMCID: PMC5864866 DOI: 10.3389/fvets.2018.00053] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Accepted: 03/02/2018] [Indexed: 12/14/2022] Open
Abstract
Although the utility and benefits of anesthesia and analgesia are irrefutable, their practice is not void of risks. Almost all drugs that produce anesthesia endanger cardiovascular stability by producing dose-dependent impairment of cardiac function, vascular reactivity, and compensatory autoregulatory responses. Whereas anesthesia-related depression of cardiac performance and arterial vasodilation are well recognized adverse effects contributing to anesthetic risk, far less emphasis has been placed on effects impacting venous physiology and venous return. The venous circulation, containing about 65–70% of the total blood volume, is a pivotal contributor to stroke volume and cardiac output. Vasodilation, particularly venodilation, is the primary cause of relative hypovolemia produced by anesthetic drugs and is often associated with increased venous compliance, decreased venous return, and reduced response to vasoactive substances. Depending on factors such as patient status and monitoring, a state of relative hypovolemia may remain clinically undetected, with impending consequences owing to impaired oxygen delivery and tissue perfusion. Concurrent processes related to comorbidities, hypothermia, inflammation, trauma, sepsis, or other causes of hemodynamic or metabolic compromise, may further exacerbate the condition. Despite scientific and technological advances, clinical monitoring and treatment of relative hypovolemia still pose relevant challenges to the anesthesiologist. This short perspective seeks to define relative hypovolemia, describe the venous system’s role in supporting normal cardiovascular function, characterize effects of anesthetic drugs on venous physiology, and address current considerations and challenges for monitoring and treatment of relative hypovolemia, with focus on insights for future therapies.
Collapse
Affiliation(s)
- Jessica Noel-Morgan
- Center for Cardiovascular & Pulmonary Research, The Research Institute at Nationwide Children's Hospital, Columbus, OH, United States
| | - William W Muir
- QTest Labs, Columbus, OH, United States.,College of Veterinary Medicine, Lincoln Memorial University, Harrogate, TN, United States
| |
Collapse
|