Whapham CA, Walker JT. Too much ado about data: Continuous remote monitoring of water temperatures, circulation and throughput can assist in the reduction of hospital-associated waterborne infections. J Hosp Infect 2024:S0195-6701(24)00223-8. [PMID: 38960042 DOI: 10.1016/j.jhin.2024.05.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 05/14/2024] [Accepted: 05/16/2024] [Indexed: 07/05/2024]
Abstract
BACKGROUND National and international guidance provides advice on maintenance and management of water systems in healthcare buildings, however, healthcare-associated waterborne infections (HAWI) are increasing. This narrative review identifies parameters critical to water quality in healthcare buildings and assesses if remote sensor monitoring can deliver safe water systems thus reducing HAWI. METHOD A narrative review was performed using the following search terms 1) consistent water temperature AND waterborne pathogen control OR nosocomial infection 2) water throughput AND waterborne pathogen control OR nosocomial infection 3) remote monitoring of in-premise water systems AND continuous surveillance for temperature OR throughput OR flow OR use. Databases employed were PubMed, CDSR (Clinical Study Data Request) and DARE (Database of Abstracts of Reviews of Effects) from Jan 2013 - Mar 2024. FINDINGS Single ensuite-patient rooms, expansion of wash-hand basins, widespread glove use, alcohol gel and wipes have increased water system stagnancy resulting in amplification of waterborne pathogens and transmission risk of Legionella, Pseudomonas and Non-Tuberculous Mycobacteria. Manual monitoring does not represent temperatures across large complex water systems. This review deems that multiple point continuous remote sensor monitoring is effective at identifying redundant and low use outlets, hydraulic imbalance and inconsistent temperature delivery across in-premise water systems. CONCLUSION As remote monitoring becomes more common there will be greater recognition of failures in temperature control, hydraulics and balancing in water systems and there remains much to learn as we adopt this developing technology within our hospitals.
Collapse
Affiliation(s)
- C A Whapham
- Independent Water Hygiene Consultant, Ludlow UK.
| | - J T Walker
- Independent Microbiology Consultant, Walker on Water, Salisbury UK
| |
Collapse
|
2
|
Párraga-Niño N, Cortès-Tarragó R, Quero S, Garcia-Núñez M, Arqué E, Sabaté S, Ramirez D, Gavaldà L. Persistence of viable but nonculturable Legionella pneumophila state in hospital water systems: A hidden enemy? THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 927:172410. [PMID: 38608884 DOI: 10.1016/j.scitotenv.2024.172410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 04/09/2024] [Accepted: 04/09/2024] [Indexed: 04/14/2024]
Abstract
There is little evidence of the long-term consequences of maintaining sanitary hot water at high temperatures on the persistence of Legionella in the plumbing system. The aims of this study were to describe the persistence and genotypic variability of L. pneumophila in a hospital building with two entirely independent hot water distribution systems, and to estimate the thermotolerance of the genotypic variants by studying the quantity of VBNC L. pneumophila. Eighty isolates from 55 water samples obtained between the years 2012-2017 were analyzed. All isolates correspond to L. pneumophila serogroup 6. The isolates were discriminated in four restriction patterns by pulsed-field gel electrophoresis. In one installation, pattern A + Aa predominated, accounting for 75.8 % of samples, while the other installation exhibited pattern B as the most frequent (81.8 % of samples; p < 0.001). The mean temperature of the isolates was: 52.6 °C (pattern A + Aa) and 55.0 °C (pattern B), being significantly different. Nine strains were selected as representative among patterns to study their thermotolerance by flow-cytometry after 24 h of thermic treatment. VBNC bacteria were detected in all samples. After thermic treatment at 50 °C, 52.0 % of bacteria had an intact membrane, and after 55 °C this percentage decreased to 23.1 %. Each pattern exhibited varying levels of thermotolerance. These findings indicate that the same hospital building can be colonized with different predominant types of Legionella if it has independent hot water installations. Maintaining a minimum temperature of 50 °C at distal points of the system would allow the survival of replicative L. pneumophila. However, the presence of Legionella in hospital water networks is underestimated if culture is considered as the standard method for Legionella detection, because VBNC do not grow on culture plates. This phenomenon can carry implications for the Legionella risk management plans in hospitals that adjust their control measures based on the microbiological surveillance of water.
Collapse
Affiliation(s)
- Noemí Párraga-Niño
- Clinical and environmental infectious diseases study group, Fundació Institut d'Investigació Germans Trias i Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916 Badalona, Barcelona, Spain; Fundació Lluita contra les Infeccions, Carretera de Can Ruti, 08916 Badalona, Barcelona, Spain.
| | - Roger Cortès-Tarragó
- Clinical and environmental infectious diseases study group, Fundació Institut d'Investigació Germans Trias i Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916 Badalona, Barcelona, Spain
| | - Sara Quero
- Clinical and environmental infectious diseases study group, Fundació Institut d'Investigació Germans Trias i Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916 Badalona, Barcelona, Spain; Fundació Lluita contra les Infeccions, Carretera de Can Ruti, 08916 Badalona, Barcelona, Spain; CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Av. Monforte de Lemos, 3-5. Pabellón 11. Planta 0, 28029 Madrid, Spain; Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí (I3PT-CERCA), Universitat Autònoma de Barcelona, Plaça Torre de l'Aigua, s/n, 08208 Sabadell, Barcelona, Spain
| | - Marian Garcia-Núñez
- Clinical and environmental infectious diseases study group, Fundació Institut d'Investigació Germans Trias i Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916 Badalona, Barcelona, Spain
| | - Elisenda Arqué
- Clinical and environmental infectious diseases study group, Fundació Institut d'Investigació Germans Trias i Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916 Badalona, Barcelona, Spain
| | - Sara Sabaté
- Agència de Salut Pública de Barcelona (ASPB), Plaza Lesseps 1, 08023 Barcelona, Spain; Institut d'Investigació Biomèdica Sant Pau (IIB SANT PAU), Sant Quintí 77-79, 08041 Barcelona, Spain
| | - Dolors Ramirez
- Department of Preventive Medicine-Hospital Hygiene. Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - Laura Gavaldà
- Department of Preventive Medicine-Hospital Hygiene. Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| |
Collapse
|
3
|
Farina C, Cacciabue E, Averara F, Ferri N, Vailati F, Del Castillo G, Serafini A, Fermi B, Doniselli N, Pezzoli F. Water Safety Plan, Monochloramine Disinfection and Extensive Environmental Sampling Effectively Control Legionella and Other Waterborne Pathogens in Nosocomial Settings: The Ten-Year Experience of an Italian Hospital. Microorganisms 2023; 11:1794. [PMID: 37512966 PMCID: PMC10384652 DOI: 10.3390/microorganisms11071794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023] Open
Abstract
Legionella contamination control is crucial in healthcare settings where patients suffer an increased risk of disease and fatal outcome. To ensure an effective management of this health hazard, the accurate application of a hospital-specific Water Safety Plan (WSP), the choice of a suitable water disinfection system and an extensive monitoring program are required. Here, the ten-year experience of an Italian hospital is reported: since its commissioning, Legionellosis risk management has been entrusted to a multi-disciplinary Working Group, applying the principles of the World Health Organization's WSP. The disinfection strategy to prevent Legionella and other waterborne pathogens relies on the treatment of domestic hot water with a system ensuring the in situ production and dosage of monochloramine. An average of 250 samples/year were collected and analyzed to allow an accurate assessment of the microbiological status of water network. With the aim of increasing the monitoring sensitivity, in addition to the standard culture method, an optimized MALDI-ToF MS-based strategy was applied, allowing the identification of Legionella species and other relevant opportunistic pathogens. Data collected so far confirmed the effectiveness of this multidisciplinary approach: the fraction of positive samples never overcame 1% on a yearly basis and Legionnaires' Disease cases never occurred.
Collapse
Affiliation(s)
- Claudio Farina
- Microbiology and Virology Laboratory, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| | - Eleonora Cacciabue
- Health Care Coordination Offices, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| | - Franca Averara
- Department of Health Care Professions, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| | - Nadia Ferri
- Microbiology and Virology Laboratory, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| | - Francesca Vailati
- Microbiology and Virology Laboratory, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| | | | | | - Beatrice Fermi
- Sanipur S.p.A., 25020 Flero, Italy
- ESCMID Study Group for Legionella Infections (ESGLI), 4001 Basel, Switzerland
| | - Nicola Doniselli
- Sanipur S.p.A., 25020 Flero, Italy
- ESCMID Study Group for Legionella Infections (ESGLI), 4001 Basel, Switzerland
| | - Fabio Pezzoli
- Health Care Coordination Offices, ASST "Papa Giovanni XXIII", 24127 Bergamo, Italy
| |
Collapse
|
4
|
Grimard-Conea M, Prévost M. Controlling Legionella pneumophila in Showerheads: Combination of Remedial Intervention and Preventative Flushing. Microorganisms 2023; 11:1361. [PMID: 37374862 DOI: 10.3390/microorganisms11061361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/17/2023] [Accepted: 05/20/2023] [Indexed: 06/29/2023] Open
Abstract
Shock chlorination and remedial flushing are suggested to address Legionella pneumophila (Lp) contamination in buildings or during their (re)commissioning. However, data on general microbial measurements (adenosine tri-phosphate [ATP], total cell counts [TCC]), and the abundance of Lp are lacking to support their temporary implementation with variable water demands. In this study, the weekly short-term (3-week) impact of shock chlorination (20-25 mg/L free chlorine, 16 h) or remedial flushing (5-min flush) combined with distinct flushing regimes (daily, weekly, stagnant) was investigated in duplicates of showerheads in two shower systems. Results showed that the combination of stagnation and shock chlorination prompted biomass regrowth, with ATP and TCC in the first draws reaching large regrowth factors of 4.31-7.07-fold and 3.51-5.68-fold, respectively, from baseline values. Contrastingly, remedial flushing followed by stagnation generally resulted in complete or larger regrowth in Lp culturability and gene copies (gc). Irrespective of the intervention, daily flushed showerheads resulted in significantly (p < 0.05) lower ATP and TCC, as well as lower Lp concentrations than weekly flushes, in general. Nonetheless, Lp persisted at concentrations ranging from 11 to 223 as the most probable number per liter (MPN/L) and in the same order of magnitude (103-104 gc/L) than baseline values after remedial flushing, despite daily/weekly flushing, unlike shock chlorination which suppressed Lp culturability (down 3-log) for two weeks and gene copies by 1-log. This study provides insights on the most optimal short-term combination of remedial and preventative strategies that can be considered pending the implementation of suitable engineering controls or building-wide treatment.
Collapse
Affiliation(s)
- Marianne Grimard-Conea
- Industrial Chair in Drinking Water, Department of Civil, Mining and Geological Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada
| | - Michèle Prévost
- Industrial Chair in Drinking Water, Department of Civil, Mining and Geological Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada
| |
Collapse
|
5
|
Persistent contamination of a hospital hot water network by Legionellapneumophila. Int J Hyg Environ Health 2023; 250:114143. [PMID: 36907106 DOI: 10.1016/j.ijheh.2023.114143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/20/2023] [Accepted: 02/20/2023] [Indexed: 03/12/2023]
Abstract
OBJECTIVES We assessed the contamination with Legionella pneumophila (Lp) of the hot water network (HWN) of a hospital, mapped the risk of contamination, and evaluated the relatedness of isolates. We further validated phenotypically the biological features that could account for the contamination of the network. METHODS We collected 360 water samples from October 2017 to September 2018 in 36 sampling points of a HWN of a building from a hospital in France. Lp were quantified and identified with culture-based methods and serotyping. Lp concentrations were correlated with water temperature, date and location of isolation. Lp isolates were genotyped by pulsed-field gel electrophoresis and compared to a collection of isolates retrieved in the same HWN two years later, or in other HWN from the same hospital. RESULTS 207/360 (57.5%) samples were positive with Lp. In the hot water production system, Lp concentration was negatively associated with water temperature. In the distribution system, the risk of recovering Lp decreased when temperature was >55 °C (p < 10-3), the proportion of samples with Lp increased with distance from the production network (p < 10-3), and the risk of finding high loads of Lp increased 7.96 times in summer (p = 0.001). All Lp isolates (n = 135) were of serotype 3, and 134 (99.3%) shared the same pulsotype which is found two years later (Lp G). In vitro competition experiments showed that a 3-day culture of Lp G on agar inhibited the growth of a different pulsotype of Lp (Lp O) contaminating another HWN of the same hospital (p = 0.050). We also found that only Lp G survived to a 24h-incubation in water at 55 °C (p = 0.014). CONCLUSION We report here a persistent contamination with Lp of a hospital HWN. Lp concentrations were correlated with water temperature, season, and distance from the production system. Such persistent contamination could be due to biotic parameters such as intra-Legionella inhibition and tolerance to high temperature, but also to the non-optimal configuration of the HWN that prevented the maintenance of high temperature and optimal water circulation.
Collapse
|
6
|
Nakade J, Nakamura Y, Katayama Y, Obata H, Takahashi Y, Zaimoku Y, Fujii Y, Iwata Y. Systematic active environmental surveillance successfully identified and controlled the Legionella contamination in the hospital. J Infect Chemother 2022; 29:43-47. [PMID: 36162645 DOI: 10.1016/j.jiac.2022.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 09/09/2022] [Accepted: 09/12/2022] [Indexed: 11/17/2022]
Abstract
INTRODUCTION Legionella disease can manifest as severe respiratory tract infection with a high mortality rate and is sometimes associated with a hospital outbreak by a contaminated water supply. A patient with breast cancer admitted about a month before. High fever was observed 18 days after admission and the Legionella antigen test showed the positive result. METHODS Due to the incidence of Legionella infection, we demonstrated the active surveillance of Legionella contamination in the entire hospital. RESULTS Cultures of her environmental samples revealed that hot water in two bathrooms were contaminated with Legionella. In our hospital, the hot water is heated and pumped up on the roof and distributed to each room. The contaminated bathrooms were related to the same plumbing. Therefore, we further collected samples throughout the hot water system. Legionella was not detected in the central part of the system. However, we detected Legionella in the hot water sampled from other five rooms, which were also associated with the same plumbing of the two bathrooms. The temperature and chlorine concentration of the hot water were not high enough to inactivate Legionella at the end of the plumbing. After the adjustment of the water temperature and chlorine concentration, Legionella became undetectable. Our prompt and active surveillance successfully identified the plumbing of the hot water system as the source of Legionella contamination and took precautions against future outbreaks. CONCLUSIONS Monitoring of water temperature and chloride concentration at the end of the hot water circulation is important to prevent nosocomial Legionella disease.
Collapse
Affiliation(s)
- Junya Nakade
- Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Department of Hospital Pharmacy, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yoko Nakamura
- Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Division of Nursing, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yusuke Katayama
- Division of Nursing, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Hiroyuki Obata
- Facilities Department, Takara-machi Facility Support Office, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yoshinori Takahashi
- Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Department of Rheumatology, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yoshitaka Zaimoku
- Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Department of Hematology, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yumi Fujii
- Department of Breast Surgery, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yasunori Iwata
- Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Department of Nephrology and Laboratory Medicine, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan.
| |
Collapse
|
7
|
Ortí-Lucas RM, Luciano E. New immunomagnetic separation method to analyze risk factors for Legionella colonization in health care centres. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2022; 32:744-750. [PMID: 35264765 PMCID: PMC8906530 DOI: 10.1038/s41370-022-00421-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 02/09/2022] [Accepted: 02/10/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND It's pivotal to control the presence of legionella in sanitary structures. So, it's important to determine the risk factors associated with Legionella colonization in health care centres. In recent years that is why new diagnostic techniques have been developed. OBJECTIVE To evaluate risks factors for Legionella colonization using a novel and more sensitive Legionella positivity index. METHODS A total of 204 one-litre water samples (102 cold water samples and 102 hot water samples), were collected from 68 different sampling sites of the hospital water system and tested for Legionella spp. by two laboratories using culture, polymerase chain reaction and a method based on immunomagnetic separation (IMS). A Legionella positivity index was defined to evaluate Legionella colonization and associated risk factors in the 68 water samples sites. We performed bivariate analyses and then logistic regression analysis with adjustment of potentially confounding variables. We compared the performance of culture and IMS methods using this index as a new gold standard to determine if rapid IMS method is an acceptable alternative to the use of slower culture method. RESULTS Based on the new Legionella positivity index, no statistically significant differences were found neither between laboratories nor between methods (culture, IMS). Positivity was significantly correlated with ambulatory health assistance (p = 0.05) and frequency of use of the terminal points. The logistic regression model revealed that chlorine (p = 0.009) and the frequency of use of the terminal points (p = 0.001) are predictors of Legionella colonization. Regarding this index, the IMS method proved more sensitive (69%) than culture method (65.4%) in hot water samples. SIGNIFICANCE We showed that the frequency of use of terminal points should be considered when examining environmental Legionella colonization, which can be better evaluated using the provided Legionella positivity index. This study has implications for the prevention of Legionnaires' disease in hospital settings.
Collapse
Affiliation(s)
- Rafael Manuel Ortí-Lucas
- Research group on Public Health and Patient Safety, Universidad Católica de Valencia San Vicente Mártir, Valencia, Spain.
- Department of Preventive Medicine, Hospital Clínico Universitario de Valencia, Valencia, Spain.
| | - Eugenio Luciano
- Department of Preventive Medicine, Hospital Clínico Universitario de Valencia, Valencia, Spain.
- Escuela de Doctorado, Universidad Católica de Valencia San Vicente Mártir, Valencia, Spain.
| |
Collapse
|
8
|
Evaluation of a Most Probable Number Method for Detection and Quantification of Legionella pneumophila. Pathogens 2022; 11:pathogens11070789. [PMID: 35890033 PMCID: PMC9324539 DOI: 10.3390/pathogens11070789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/02/2022] [Accepted: 07/07/2022] [Indexed: 11/17/2022] Open
Abstract
The detection and enumeration of Legionella pneumophila (L. pneumophila) in water is crucial for water quality management, human health and has been a research hotspot worldwide. Due to the time-consuming and complicated operation of the plate culture method, it is necessary to adopt a fast and effective method for application. The present study aimed to comprehensively evaluate the performance and applicability of the MPN method by comparing its qualitative and quantitative results with the GB/T 18204.5-2013 and ISO methods, respectively. The qualitative results showed that 372 samples (53%) were negative for both methods; 315 samples (45%) were positively determined by the MPN method, compared with 211 samples (30%) using GB/T 18204.5-2013. The difference in the detection rate between the two methods was statistically significant. In addition, the quantitative results showed that the concentration of L. pneumophila by the MPN method was greater than ISO 11731 and the difference was statistically significant. However, the two methods were different but highly correlated (r = 0.965, p < 0.001). The specificity and sensitivity of the MPN method were 89.85% and 95.73%, respectively. Overall, the results demonstrated that the MPN method has higher sensitivity, a simple operation process and good application prospects in the routine monitoring of L. pneumophila from water samples.
Collapse
|
9
|
Zhan XY, Yang JL, Sun H, Zhou X, Qian YC, Huang K, Leng Y, Huang B, He Y. Presence of Viable, Clinically Relevant Legionella Bacteria in Environmental Water and Soil Sources of China. Microbiol Spectr 2022; 10:e0114021. [PMID: 35438512 PMCID: PMC9241679 DOI: 10.1128/spectrum.01140-21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 03/11/2022] [Indexed: 12/12/2022] Open
Abstract
The distribution of pathogenic Legionella in the environmental soil and water of China has not been documented yet. In this study, Legionella was detected in 129 of 575 water (22.43%) and 41 of 442 soil samples (9.28%) by culture. Twelve Legionella species were identified, of which 11 were disease-associated. Of the Legionella-positive samples, 109 of 129 (84.50%) water and 29 of 41 (70.73%) soil were positive for L. pneumophila, which accounted for about 75% of Legionella isolates in both water and soil, suggesting L. pneumophila was the most frequent species. Soil showed a higher diversity of Legionella spp. as compared with water (0.6279 versus 0.4493). In contrast, serogroup (sg) 1 was more prevalent among L. pneumophila isolates from water than from soil (26.66% versus 12.21%). Moreover, many disease-associated sequence types (STs) of L. pneumophila were found in China. Intragenic recombination was acting on L. pneumophila from both water and soil. Phylogeny, population structure, and molecular evolution analyses revealed a probable existence of L. pneumophila isolates with a special genetic background that is more adaptable to soil or water sources and a small proportion of genetic difference between water and soil isolates. The detection of viable, clinically relevant Legionella demonstrates soil as another source for harboring and dissemination of pathogenic Legionella bacteria in China. Future research should assess the implication in public health with the presence of Legionella in the soil and illustrate the genetic and pathogenicity difference of Legionella between water and soil, particularly the most prevalent L. pneumophila. IMPORTANCE Pathogenic Legionella spp. is the causative agent of Legionnaires' disease (LD), and L. pneumophila is the most common one. Most studies have focused on L. pneumophila from water and clinical samples. However, the soil is another important reservoir for this bacterium, and the distribution of Legionella spp. in water and soil sources has not been compared and documented in China yet. Discovering the distribution of Legionella spp. and L. pneumophila in the two environments may help a deep understanding of the pathogenesis and molecular evolution of the bacterium. Our research systematically uncovered the distributions of Legionella spp. in different regions and sources (e.g., water and soil) of China. Moreover, phylogeny, population structure, and molecular evolution study revealed the possible existence of L. pneumophila with a special genetic background that is more adaptable to soil or water sources, and genetic difference may exist.
Collapse
Affiliation(s)
- Xiao-Yong Zhan
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Jin-Lei Yang
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Honghua Sun
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Xuefu Zhou
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Yi-Chao Qian
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Ke Huang
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Yang Leng
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Bihui Huang
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Yulong He
- The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| |
Collapse
|
10
|
Inkster T, Peters C, Dancer S. Safe design and maintenance of bone marrow transplant units: a narrative review. Clin Microbiol Infect 2022; 28:1091-1096. [DOI: 10.1016/j.cmi.2022.03.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 03/25/2022] [Accepted: 03/26/2022] [Indexed: 11/03/2022]
|
11
|
Variable Legionella Response to Building Occupancy Patterns and Precautionary Flushing. Microorganisms 2022; 10:microorganisms10030555. [PMID: 35336130 PMCID: PMC8950775 DOI: 10.3390/microorganisms10030555] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 02/21/2022] [Accepted: 02/26/2022] [Indexed: 02/04/2023] Open
Abstract
When stay-at-home orders were issued to slow the spread of COVID-19, building occupancy (and water demand) was drastically decreased in many buildings. There was concern that widespread low water demand may cause unprecedented Legionella occurrence and Legionnaires’ disease incidence. In lieu of evidenced-based guidance, many people flushed their water systems as a preventative measure, using highly variable practices. Here, we present field-scale research from a building before, during, and after periods of low occupancy, and controlled stagnation experiments. We document no change, a > 4-log increase, and a > 1.5-log decrease of L. pneumophila during 3- to 7-week periods of low water demand. L. pneumophila increased by > 1-log after precautionary flushing prior to reoccupancy, which was repeated in controlled boiler flushing experiments. These results demonstrate that the impact of low water demand (colloquially called stagnation) is not as straight forward as is generally assumed, and that some flushing practices have potential unintended consequences. In particular, stagnation must be considered in context with other Legionella growth factors like temperature and flow profiles. Boiler flushing practices that dramatically increase the flow rate and rapidly deplete boiler temperature may mobilize Legionella present in biofilms and sediment.
Collapse
|
12
|
Cazals M, Bédard E, Doberva M, Faucher S, Prévost M. Compromised Effectiveness of Thermal Inactivation of Legionella pneumophila in Water Heater Sediments and Water, and Influence of the Presence of Vermamoeba vermiformis. Microorganisms 2022; 10:microorganisms10020443. [PMID: 35208896 PMCID: PMC8874534 DOI: 10.3390/microorganisms10020443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 11/21/2022] Open
Abstract
Intermittent reduction of temperature set-points and periodic shutdowns of water heaters have been proposed to reduce energy consumption in buildings. However, the consequences of such measures on the occurrence and proliferation of Legionella pneumophila (Lp) in hot water systems have not been documented. The impact of single and repeated heat shocks was investigated using an environmental strain of L. pneumophila and a reference strain of V. vermiformis. Heat shocks at temperatures ranging from 50 °C to 70 °C were applied for 1 h and 4 h in water and water heaters loose deposits (sludge). The regrowth potential of heat-treated culturable L. pneumophila in presence of V. vermiformis in water heaters sludges was evaluated. A 2.5-log loss of culturability of L. pneumophila was observed in simulated drinking water at 60 °C while a 4-log reduction was reached in water heaters loose deposits. Persistence of Lp after 4 h at 55 °C was shown and the presence of V. vermiformis in water heater’s loose deposits resulted in a drastic amplification (5-log). Results show that thermal inactivation by heat shock is only efficient at elevated temperatures (50 °C) in both water and loose deposits. The few remaining organisms can rapidly proliferate during storage at lower temperature in the presence of hosts.
Collapse
Affiliation(s)
- Margot Cazals
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
- Correspondence:
| | - Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| | - Margot Doberva
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| | - Sébastien Faucher
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC H9X 3V9, Canada;
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| |
Collapse
|
13
|
Molina JJ, Bennassar M, Palacio E, Crespi S. Low Efficacy of Periodical Thermal Shock for Long-Term Control of Legionella spp. in Hot Water System of Hotels. Pathogens 2022; 11:pathogens11020152. [PMID: 35215095 PMCID: PMC8875211 DOI: 10.3390/pathogens11020152] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 01/21/2022] [Accepted: 01/21/2022] [Indexed: 02/04/2023] Open
Abstract
Different guidelines and regulations for the prevention of legionellosis in public facilities include the recommendation of a periodical thermal shock in the hot water system. The purpose of this study was to assess the efficacy of periodical thermal shocks along a 1-year period on the presence of Legionella spp. in the domestic hot water system of hotels. The Legionella testing results from the period January–December 2019 coming from a group of 77 hotel facilities in the Balearic Islands (Spain) conducting periodical thermal shocks were analyzed. A second group of 44 hotels operating without periodical thermal shocks was used for a comparative analysis. In the facilities where the periodical thermal shock was performed, 16.0% of the results (429 hot water samples collected) were positive for Legionella spp., compared to 21.1% (298 samples), where periodical thermal shock was not performed. Overall, in the thermal shock group, 32.5% of the sites presented at least 1 positive sample along the period of study versus 45.5% in the control group. None of these differences was statistically significant (p-value > 0.05). These findings suggest that the efficacy of regular thermal shock for long-term control of Legionella spp. in domestic hot water systems of hotels is low.
Collapse
Affiliation(s)
- Jhon J. Molina
- Biolinea Int., 07007 Palma, Spain; (J.J.M.); (M.B.)
- Environmental Analytical Chemistry Group, University of the Balearic Islands, 07122 Palma, Spain;
| | | | - Edwin Palacio
- Environmental Analytical Chemistry Group, University of the Balearic Islands, 07122 Palma, Spain;
| | - Sebastian Crespi
- Biolinea Int., 07007 Palma, Spain; (J.J.M.); (M.B.)
- Correspondence: ; Tel.: +34-971724701
| |
Collapse
|
14
|
Walker JT, McDermott PJ. Confirming the Presence of Legionella pneumophila in Your Water System: A Review of Current Legionella Testing Methods. J AOAC Int 2021; 104:1135-1147. [PMID: 33484265 PMCID: PMC8378878 DOI: 10.1093/jaoacint/qsab003] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/18/2020] [Accepted: 12/18/2020] [Indexed: 12/24/2022]
Abstract
Legionnaires' disease has been recognized since 1976 and Legionella pneumophila still accounts for more than 95% of cases. Approaches in countries, including France, suggest that focusing risk reduction specifically on L. pneumophila is an effective strategy, as detecting L. pneumophila has advantages over targeting multiple species of Legionella. In terms of assays, the historically accepted plate culture method takes 10 days for confirmed Legionella spp. results, has variabilities which affect trending and comparisons, requires highly trained personnel to identify colonies on a plate in specialist laboratories, and does not recover viable-but-non-culturable bacteria. PCR is sensitive, specific, provides results in less than 24 h, and determines the presence/absence of Legionella spp. and/or L. pneumophila DNA. Whilst specialist personnel and laboratories are generally required, there are now on-site PCR options, but there is no agreement on comparing genome units to colony forming units and action limits. Immunomagnetic separation assays are culture-independent, detect multiple Legionella species, and results are available in 24 h, with automated processing options. Field-use lateral flow devices provide presence/absence determination of L. pneumophila serogroup 1 where sufficient cells are present, but testing potable waters is problematic. Liquid culture most probable number (MPN) assays provide confirmed L. pneumophila results in 7 days that are equivalent to or exceed plate culture, are robust and reproducible, and can be performed in a variety of laboratory settings. MPN isolates can be obtained for epidemiological investigations. This accessible, non-technical review will be of particular interest to building owners, operators, risk managers, and water safety groups and will enable them to make informed decisions to reduce the risk of L. pneumophila.
Collapse
|
15
|
Pereira A, Silva AR, Melo LF. Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands. Microorganisms 2021; 9:microorganisms9061212. [PMID: 34205095 PMCID: PMC8228026 DOI: 10.3390/microorganisms9061212] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 11/16/2022] Open
Abstract
Legionella is responsible for the life-threatening pneumonia commonly known as Legionnaires’ disease or legionellosis. Legionellosis is known to be preventable if proper measures are put into practice. Despite the efforts to improve preventive approaches, Legionella control remains one of the most challenging issues in the water treatment industry. Legionellosis incidence is on the rise and is expected to keep increasing as global challenges become a reality. This puts great emphasis on prevention, which must be grounded in strengthened Legionella management practices. Herein, an overview of field-based studies (the system as a test rig) is provided to unravel the common roots of research and the main contributions to Legionella’s understanding. The perpetuation of a water-focused monitoring approach and the importance of protozoa and biofilms will then be discussed as bottom-line questions for reliable Legionella real-field surveillance. Finally, an integrated monitoring model is proposed to study and control Legionella in water systems by combining discrete and continuous information about water and biofilm. Although the successful implementation of such a model requires a broader discussion across the scientific community and practitioners, this might be a starting point to build more consistent Legionella management strategies that can effectively mitigate legionellosis risks by reinforcing a pro-active Legionella prevention philosophy.
Collapse
|
16
|
Papagianeli SD, Aspridou Z, Didos S, Chochlakis D, Psaroulaki A, Koutsoumanis K. Dynamic modelling of Legionella pneumophila thermal inactivation in water. WATER RESEARCH 2021; 190:116743. [PMID: 33352528 DOI: 10.1016/j.watres.2020.116743] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 12/09/2020] [Accepted: 12/10/2020] [Indexed: 06/12/2023]
Abstract
A predictive mathematical model describing the effect of temperature on the inactivation of Legionella pneumophila in water was developed. Thermal inactivation of L. pneumophila was monitored under isothermal conditions (51 - 61°C). A primary log-linear model was fitted to the inactivation data and the estimated D values ranged from 0.23 to 25.31 min for water temperatures from 61 to 51°C, respectively. The effect of temperature on L. pneumophila inactivation was described using a secondary model, and the model parameters z value and Dref (D-value at 55°C) were estimated at 5.54°C and 3.47 min, respectively. The developed model was further validated under dynamic temperature conditions mimicking various conditions of water thermal disinfection in plumbing systems. The results indicated that the model can satisfactorily predict thermal inactivation of the pathogen at dynamic temperature environments and effectively translate water temperature profiles to cell number reduction. The application of the model in combination with effective temperature monitoring could provide the basis of an integrated preventive approach for the effective control of L. pneumophila in plumbing systems.
Collapse
Affiliation(s)
- Styliani Dimitra Papagianeli
- Laboratory of Food Microbiology and Hygiene, Department of Food Science and Technology, School of Agriculture, Faculty of Agriculture, Forestry and Natural Environment, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Zafeiro Aspridou
- Laboratory of Food Microbiology and Hygiene, Department of Food Science and Technology, School of Agriculture, Faculty of Agriculture, Forestry and Natural Environment, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Spyros Didos
- Laboratory of Food Microbiology and Hygiene, Department of Food Science and Technology, School of Agriculture, Faculty of Agriculture, Forestry and Natural Environment, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Dimosthenis Chochlakis
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, Unit of Water, Food and Environmental Microbiology, School of Medicine, University of Crete, Heraklion, 71110, Greece
| | - Anna Psaroulaki
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, Unit of Water, Food and Environmental Microbiology, School of Medicine, University of Crete, Heraklion, 71110, Greece
| | - Konstantinos Koutsoumanis
- Laboratory of Food Microbiology and Hygiene, Department of Food Science and Technology, School of Agriculture, Faculty of Agriculture, Forestry and Natural Environment, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece.
| |
Collapse
|
17
|
Quero S, Párraga-Niño N, Garcia-Núñez M, Pedro-Botet ML, Gavaldà L, Mateu L, Sabrià M, Mòdol JM. The impact of pipeline changes and temperature increase in a hospital historically colonised with Legionella. Sci Rep 2021; 11:1916. [PMID: 33479467 PMCID: PMC7820426 DOI: 10.1038/s41598-021-81625-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 01/01/2021] [Indexed: 01/25/2023] Open
Abstract
Healthcare-related Legionnaires’ disease has a devastating impact on high risk patients, with a case fatality rate of 30–50%. Legionella prevention and control in hospitals is therefore crucial. To control Legionella water colonisation in a hospital setting we evaluated the effect of pipeline improvements and temperature increase, analysing 237 samples over a 2-year period (first year: 129, second year: 108). In the first year, 25.58% of samples were positive for Legionella and 16.67% for amoeba. Assessing the distance of the points analysed from the hot water tank, the most distal points presented higher proportion of Legionella colonisation and lower temperatures (nearest points: 6.4% colonised, and temperature 61.4 °C; most distal points: 50% and temperature 59.1 °C). After the first year, the hot water system was repaired and the temperature stabilised. This led to a dramatic reduction in Legionella colonisation, which was negative in all the samples analysed; however, amoeba colonisation remained stable. This study shows the importance of keeping the temperature stable throughout the circuit, at around 60 °C. Special attention should be paid to the most distal points of the circuit; a fall in temperature at these weak points would favour the colonisation and spread of Legionella, because amoeba (the main Legionella reservoir) are not affected by temperature.
Collapse
Affiliation(s)
- S Quero
- Infectious Diseases Unit, Fundació Institut d'Investigació Germans Trias I Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916, Badalona, Barcelona, Spain. .,CIBER de Enfermedades Respiratorias, CIBERES, Av. de Monforte de Lemos, 3-5, 28029, Madrid, Spain. .,Institut d'Investigació i Innovació Parc Taulí, I3PT, Parc Taulí, 1, 08208, Sabadell, Barcelona, Spain.
| | - N Párraga-Niño
- Infectious Diseases Unit, Fundació Institut d'Investigació Germans Trias I Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916, Badalona, Barcelona, Spain
| | - M Garcia-Núñez
- Infectious Diseases Unit, Fundació Institut d'Investigació Germans Trias I Pujol, Carretera de Can Ruti, Camí de les Escoles s/n, 08916, Badalona, Barcelona, Spain.,CIBER de Enfermedades Respiratorias, CIBERES, Av. de Monforte de Lemos, 3-5, 28029, Madrid, Spain.,Institut d'Investigació i Innovació Parc Taulí, I3PT, Parc Taulí, 1, 08208, Sabadell, Barcelona, Spain
| | - M L Pedro-Botet
- CIBER de Enfermedades Respiratorias, CIBERES, Av. de Monforte de Lemos, 3-5, 28029, Madrid, Spain.,Hospital Universitari Germans Trias i Pujol, Carretera de Canyet, s/n, 08916, Badalona, Barcelona, Spain
| | - L Gavaldà
- Hospital Universitari de Bellvitge-IDIBELL, Feixa Llarga, s/n., 08907, L'Hospitalet de Llobregat, Barcelona, Spain
| | - L Mateu
- Hospital Universitari Germans Trias i Pujol, Carretera de Canyet, s/n, 08916, Badalona, Barcelona, Spain
| | - M Sabrià
- CIBER de Enfermedades Respiratorias, CIBERES, Av. de Monforte de Lemos, 3-5, 28029, Madrid, Spain.,Hospital Universitari Germans Trias i Pujol, Carretera de Canyet, s/n, 08916, Badalona, Barcelona, Spain
| | - J M Mòdol
- Hospital Universitari Germans Trias i Pujol, Carretera de Canyet, s/n, 08916, Badalona, Barcelona, Spain
| |
Collapse
|
18
|
Bertolino G, Marras L, Sanna C, Carrucciu G, Schintu M, Coroneo V. Ten-Year Retrospective Analysis of Legionella Diffusion in Hospital Water Systems and Its Serogroup Seasonal Variation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2020; 1282:93-103. [PMID: 32030638 DOI: 10.1007/5584_2020_484] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
INTRODUCTION Legionella spp. are ubiquitous aquatic organisms found to be associated with community-acquired pneumoniae (CAP) as well as hospital-acquired pneumonia (HAP). Direct inhalation of aerosols from environmental colonisation is typically the source of infection. The aim of this study was to determine the level of colonisation in hospital water supply systems in order to assess the criticality of the water distribution network and strengthen preventive measures. METHODS From 2009 to 2018, 769 water samples were collected and then analysed according to the standard methods indicated in ISO11731-2:2004 and ISO11731:2017 for Legionella detection. RESULTS The samples were positive in 37.1% cases (n. 285) and negative in 62.9% cases (n. 484). The threshold of 10,000 CFU/L was exceeded in 15.1% cases and led to decolonisation as indicated by Italian and European ECDC guidelines. In the autumn-winter period SG1 showed a positivity of 41.2% (n. 40) with a decrease in the spring-summer period with 9.6% (n. 18) of positivity. In contrast, SG2-15 showed a positivity of 30.9% (n. 30) in autumn-winter, which tends to increase to 56.9% (n. 112) in spring-summer (p < 0.001). CONCLUSION Surprisingly, besides showing a seasonal trend already described previously in the literature, the positivity of our sample was not balanced even for serogroups in the two periods. This could be due to genetic differences and ecological niches to be further investigated that could also have links with the greater pathogenicity of SG1. Environmental microbiological surveillance and risk assessment should be performed more frequently and disinfection must be carried out, especially in health facilities where people are more susceptible to infections.
Collapse
Affiliation(s)
- Giacomo Bertolino
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy. .,Pharmaceutical Department, ATS Sardegna, ASSL Cagliari, Cagliari, Italy.
| | - Luisa Marras
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Clara Sanna
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Gerolamo Carrucciu
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Marco Schintu
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Valentina Coroneo
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| |
Collapse
|
19
|
Improving Energy Efficiency of Thermal Processes in Healthcare Institutions: A Review on the Latest Sustainable Energy Management Strategies. ENERGIES 2020. [DOI: 10.3390/en13030569] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Healthcare institutions consume large amounts of energy, ranking the second highest energy-intensive buildings in the commercial sector. Within developed countries, the energy consumption of healthcare institutions may account for up to 18% of the overall energy usage in commercial sectors. Within developing countries, such as South Africa, the energy consumption of healthcare institutions is observed to be a close second to the food service sector. Energy consumption of healthcare institutions per bed typically range from 43–92 kWh per day. In this paper, the largest energy consumers in South African healthcare institutions are identified and appropriate energy-efficiency (EE) initiatives are proposed, in terms of performance, operation, equipment and technology efficiency (POET). Two main thermal energy consumers are identified as heating, ventilation and air conditioning (HVAC) and water-heating systems. These systems are critical to patient health and may be classified as non-deferrable loads. Therefore, several initiatives are suggested to improve the energy efficiency and demand-side management capability of these systems. These initiatives are subdivided into different levels: the conceptual level, active level, technical and further improvement level, as defined in the POET framework. At each level, energy-efficiency initiatives are introduced based on potential energy savings and the effort required to achieve these savings. In addition, model predictive control (MPC) approaches are discussed and reviewed as part of the further improvement section. Average possible energy savings ranged from 50%–70% at the conceptual level, while energy savings of 15%–30% may be expected for energy-efficiency initiatives at the active level. EE activities at the technical level and the further improvement level may result in savings of 50%–70% and 5%–10%, respectively.
Collapse
|
20
|
Evaluation of Legionella pneumophila Decrease in Hot Water Network of Four Hospital Buildings after Installation of Electron Time Flow Taps. WATER 2020. [DOI: 10.3390/w12010210] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Legionella spp. control is a critical issue in hospital with old water networks. Chemical disinfection methods are applied as a control measure over prolonged time periods, but Legionella may be resistant to chemical agents in pipeworks with low flow and frequent water stagnation. We evaluated Legionella spp. colonization in the hot water network of Italian hospitals after the installation of time flow taps (TFTs). In the period between 2017 and 2019, TFTs were installed in four hospital water networks. They were programmed in order to obtain a hot water flow of 192 L/day from each TFTs. A continuous chlorination system (chlorine dioxide) and a cold water pre-filtration device were applied in all the buildings. Before and after TFT installation, Legionella spp. was investigated at scheduled times. Before TFT installation, Legionella pneumophila was detected in all the hospitals with counts ranging from 2 × 102 to 1.4 × 105 CFU/L. After TFT installation, a loss in Legionella pneumophila culturability was always achieved in the period between 24 h and 15 days. Total chlorine concentration (Cl2) was detected in the range between 0.23 and 0.36 mg/L while temperature values were from 44.8 to 53.2 °C. TFTs together with chemical disinfection represent a method which improve water quality and disinfectant efficacy, reducing Legionella colonization in dead-end sections.
Collapse
|
21
|
Valciņa O, Pūle D, Mališevs A, Trofimova J, Makarova S, Konvisers G, Bērziņš A, Krūmiņa A. Co-Occurrence of Free-Living Amoeba and Legionella in Drinking Water Supply Systems. MEDICINA-LITHUANIA 2019; 55:medicina55080492. [PMID: 31443316 PMCID: PMC6723719 DOI: 10.3390/medicina55080492] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 08/07/2019] [Accepted: 08/12/2019] [Indexed: 12/15/2022]
Abstract
Background and Objectives:Legionella is one of the most important water-related pathogens. Inside the water supply systems and the biofilms, Legionella interact with other bacteria and free-living amoeba (FLA). Several amoebas may serve as hosts for bacteria in aquatic systems. This study aimed to investigate the co-occurrence of Legionella spp. and FLA in drinking water supply systems. Materials and Methods: A total of 268 water samples were collected from apartment buildings, hotels, and public buildings. Detection of Legionella spp. was performed in accordance with ISO 11731:2017 standard. Three different polymerase chain reaction (PCR) protocols were used to identify FLA. Results: Occurrence of Legionella varied from an average of 12.5% in cold water samples with the most frequent occurrence observed in hot water, in areas receiving untreated groundwater, where 54.0% of the samples were Legionella positive. The occurrence of FLA was significantly higher. On average, 77.2% of samples contained at least one genus of FLA and, depending on the type of sample, the occurrence of FLA could reach 95%. In the samples collected during the study, Legionella was always isolated along with FLA, no samples containing Legionella in the absence of FLA were observed. Conclusions: The data obtained in our study can help to focus on the extensive distribution, close interaction, and long-term persistence of Legionella and FLA. Lack of Legionella risk management plans and control procedures may promote further spread of Legionella in water supply systems. In addition, the high incidence of Legionella-related FLA suggests that traditional monitoring methods may not be sufficient for Legionella control.
Collapse
Affiliation(s)
- Olga Valciņa
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia.
| | - Daina Pūle
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
- Department of Water Engineering and Technology, Riga Technical University, LV-1658 Rīga, Latvia
| | - Artjoms Mališevs
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
| | - Jūlija Trofimova
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
| | - Svetlana Makarova
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
| | - Genadijs Konvisers
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
| | - Aivars Bērziņš
- Institute of Food Safety, Animal Health and Environment "BIOR", LV-1076 Rīga, Latvia
| | - Angelika Krūmiņa
- Department of Infectology and Dermatology, Riga Stradiņš University, LV-1007 Rīga, Latvia
| |
Collapse
|