1
|
Zhang B, Li TC, Wang X, Du CF, Zhu R. The effect of different fixation systems on oblique lumbar interbody fusion under vibration conditions. Med Eng Phys 2024; 128:104169. [PMID: 38789212 DOI: 10.1016/j.medengphy.2024.104169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 03/20/2024] [Accepted: 04/10/2024] [Indexed: 05/26/2024]
Abstract
Despite the fact that lower back pain caused by degenerative lumbar spine pathologies seriously affects the quality of life, however, there is a paucity of research on the biomechanical properties of different auxiliary fixation systems for its primary treatment (oblique lumbar interbody fusion) under vibratory environments. In order to study the effects of different fixation systems of OLIF surgery on the vibration characteristics of the human lumbar spine under whole-body vibration (WBV), a finite element (FE) model of OLIF surgery with five different fixation systems was established by modifying a previously established model of the normal lumbar spine (L1-S1). In this study, a compressive follower load of 500 N and a sinusoidal axial vertical load of ±40 N at the frequency of 5 Hz with a duration of 0.6 s was applied. The results showed that the bilateral pedicle screw fixation model had the highest resistance to cage subsidence and maintenance of disc height under WBV. In contrast, the lateral plate fixation model exerted very high stresses on important tissues, which would be detrimental to the patient's late recovery and reduction of complications. Therefore, this study suggests that drivers and related practitioners who are often in vibrating environments should have bilateral pedicle screws for OLIF surgery, and side plates are not recommended to be used as a separate immobilization system. Additionally, the lateral plate is not recommended to be used as a separate fixation system.
Collapse
Affiliation(s)
- Bin Zhang
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of mechanical engineering, Tianjin University of Technology, Tianjin, 300384, China; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin, 300384, China
| | - Tian-Cheng Li
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of mechanical engineering, Tianjin University of Technology, Tianjin, 300384, China; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin, 300384, China
| | - Xin Wang
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of mechanical engineering, Tianjin University of Technology, Tianjin, 300384, China; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin, 300384, China
| | - Cheng-Fei Du
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of mechanical engineering, Tianjin University of Technology, Tianjin, 300384, China; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin, 300384, China.
| | - Rui Zhu
- Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai, 200092, China.
| |
Collapse
|
2
|
Li J, Cao S, Zhao B. Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis. BMC Surg 2024; 24:169. [PMID: 38811965 PMCID: PMC11134660 DOI: 10.1186/s12893-024-02462-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Accepted: 05/20/2024] [Indexed: 05/31/2024] Open
Abstract
BACKGROUND Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.
Collapse
Affiliation(s)
- Jie Li
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China
| | - Shuai Cao
- Department of Orthopedics, Civil Aviation General Hospital, No. 1, Gaojing Stress, Chaoyang District, Beijing, 100123, China
| | - Bo Zhao
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China.
| |
Collapse
|
3
|
Hu Y, Liu S, Yang R, Wang H. Biomechanical Analysis of a Newly Proposed Surgical Combination (MIS Screw-Rod System for Indirect Decompression+ Interspinous Fusion System for long Term Spinal Stability) in Treatment of Lumbar Degenerative Diseases. World Neurosurg 2024; 184:e809-e820. [PMID: 38364897 DOI: 10.1016/j.wneu.2024.02.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 02/10/2024] [Indexed: 02/18/2024]
Abstract
OBJECTIVE The aim of this study is to analyze the biomechanical stability of a newly proposed surgical combination (minimally invasive surgery of screw-rod system for indirect decompression + interspinous fusion system for long term spinal stability) in treatment of lumbar degenerative diseases. METHODS The three-dimensional (3D) computed tomography (CT) image data of an adult healthy male volunteer were selected. An intact model of L4/5 was further established and validated by using Mimic and 3-matic, 3D slicer, abaqus, Python. Four surgical models were constructed. The biomechanical stability among these surgical modes was compared and analyzed using finite element analysis. RESULTS The maximum von mises on fixation system in surgical models 2 and 3 exhibited comparable values. This finding suggested that the increase in interspinous fusion did not result in a significant elevation in maximum von mises on fixation system. Compared with the third surgical model, the fourth model, which received less average von mises experienced by the screw in contact with both cancellous and cortical bone. The findings indicated that the inclusion of facet joint fusion in surgical procedures might not be necessary to increase the average von Mises stress experienced by the screw in contact with both cancellous and cortical bone. CONCLUSIONS The biomechanical stability of the newly proposed surgical combination (MIS screw-rod for indirect decompression + interspinous fusion for long term spinal stability technique) was not lower than that of the other surgical combination groups, and it might not be necessary to perform facet joint fusion during the surgery.
Collapse
Affiliation(s)
- Yunxiang Hu
- School of Graduates, Dalian Medical University, Dalian City, Liaoning Province, China; Department of Orthopedics, Dalian Municipal Central Hospital Affiliated of Dalian Medical University, Dalian City, Liaoning Province, China
| | - Sanmao Liu
- School of Graduates, Dalian Medical University, Dalian City, Liaoning Province, China; Department of Orthopedics, Dalian Municipal Central Hospital Affiliated of Dalian Medical University, Dalian City, Liaoning Province, China
| | - Rui Yang
- School of Graduates, Dalian Medical University, Dalian City, Liaoning Province, China; Department of Orthopedics, Dalian Municipal Central Hospital Affiliated of Dalian Medical University, Dalian City, Liaoning Province, China
| | - Hong Wang
- Department of Orthopedics, Dalian Municipal Central Hospital Affiliated of Dalian Medical University, Dalian City, Liaoning Province, China.
| |
Collapse
|
4
|
Li K, Cao S, Chen J, Qin J, Yuan B, Li J. Determining a relative total lumbar range of motion to alleviate adjacent segment degeneration after transforaminal lumbar interbody fusion: a finite element analysis. BMC Musculoskelet Disord 2024; 25:197. [PMID: 38443904 PMCID: PMC10913564 DOI: 10.1186/s12891-024-07322-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/28/2024] [Indexed: 03/07/2024] Open
Abstract
BACKGROUND A reduction in total lumbar range of motion (ROM) after lumbar fusion may offset the increase in intradiscal pressure (IDP) and facet joint force (FJF) caused by the abnormally increased ROM at adjacent segments. This study aimed to determine a relative total lumbar ROM rather than an ideal adjacent segment ROM to guide postoperative waist activities and further delay adjacent segment degeneration (ASD). METHODS An intact L1-S1 finite element model was constructed and validated. Based on this, a surgical model was created to allow the simulation of L4/5 transforaminal lumbar interbody fusion (TLIF). Under the maximum total L1-S1 ROM, the ROM, IDP, and FJF of each adjacent segment between the intact and TLIF models were compared to explore the biomechanical influence of lumbar fusion on adjacent segments. Subsequently, the functional relationship between total L1-S1 ROM and IDP or total L1-S1 ROM and FJF was fitted in the TLIF model to calculate the relative total L1-S1 ROMs without an increase in IDP and FJF. RESULTS Compared with those of the intact model, the ROM, IDP, and FJF of the adjacent segments in the TLIF model increased by 12.6-28.9%, 0.1-6.8%, and 0-134.2%, respectively. As the total L1-S1 ROM increased, the IDP and FJF of each adjacent segment increased by varying degrees. The relative total L1-S1 ROMs in the TLIF model were 11.03°, 12.50°, 12.14°, and 9.82° in flexion, extension, lateral bending, and axial rotation, respectively. CONCLUSIONS The relative total L1-S1 ROMs after TLIF were determined, which decreased by 19.6-29.3% compared to the preoperative ones. Guiding the patients to perform postoperative waist activities within these specific ROMs, an increase in the IDP and FJF of adjacent segments may be effectively offset, thereby alleviating ASD.
Collapse
Affiliation(s)
- Ke Li
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, Shaanxi Province, 710004, China
| | - Shuai Cao
- Department of Orthopedics, Civil Aviation General Hospital, No. 1, Gaojing Stress, Chaoyang District, Beijing, 100123, China
| | - Jing Chen
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, Shaanxi Province, 710004, China
| | - Jie Qin
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, Shaanxi Province, 710004, China
| | - Bo Yuan
- Department of Orthopedics, Civil Aviation General Hospital, No. 1, Gaojing Stress, Chaoyang District, Beijing, 100123, China
| | - Jie Li
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, Shaanxi Province, 710004, China.
| |
Collapse
|
5
|
Shen S, You X, Ren Y, Ye S. Risk Factors of Cage Subsidence Following Oblique Lumbar Interbody Fusion: A Meta-analysis and Systematic Review. World Neurosurg 2024; 183:180-186. [PMID: 38145652 DOI: 10.1016/j.wneu.2023.12.110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 12/19/2023] [Indexed: 12/27/2023]
Abstract
OBJECTIVES The aim of this systematic review was to evaluate the risk factors for cage subsidence (CS) after oblique lumbar interbody fusion (OLIF). METHODS The cohort and case-control studies which reporting potential risk factors for CS following OLIF were searched in PubMed, Embase, and Web of Science from database inception to June 17, 2023. Two researchers independently screened the literature, extracted data, and evaluated the quality of the literature according to the Newcastle Ottawa Scale. RevMan5.3 software was used for Meta analysis. χ2 statistics and I2 statistics were used to evaluate heterogeneity, and the analysis results were represented by forest plots. RESULTS A total of 8 studies with 280 cases of CS from 832 patients who underwent OLIF met the inclusion criteria. Elderly patients over 60 years old (odds ratio [OR] 2.44, 95% CI 1.38-4.31, P = 0.002), osteoporosis (OR 4.18, 95% CI 2.30-7.61, P = 0.002), end plate injury (OR 5.72, 95% CI 2.32-14.11, P = 0.0002), and overdistraction of intervertebral space (OR 1.67, 95% CI 1.3 2-2.11, P < 0.0001) were potential risk factors, while Hounsfield units value of the vertebral body (OR 0.97, 95% CI 0.95-1.00, P = 0.02) is a protective factor. The number of operative segments did not increase the risk of CS. CONCLUSIONS Older age, osteoporosis, endplate injury, and overdistraction of the intervertebral space may increase the risk of CS after OLIF. Although the incidence rate of CS is low, implementing effective preventions is a priority for clinicians based on these risk factors.
Collapse
Affiliation(s)
- Shufeng Shen
- Department of Spinal Surgery, Yuyao People's Hospital, Zhejiang Province, China.
| | - Xinmao You
- Department of Spinal Surgery, Yuyao People's Hospital, Zhejiang Province, China
| | - Yingqing Ren
- Department of Spinal Surgery, Yuyao People's Hospital, Zhejiang Province, China
| | - Senqi Ye
- Department of Spinal Surgery, Yuyao People's Hospital, Zhejiang Province, China
| |
Collapse
|
6
|
Lv X, Nuertai Y, Wang Q, Zhang D, Hu X, Liu J, Zeng Z, Huang R, Huang Z, Zhao Q, Li W, Zhang Z, Gao L. Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation. Neurospine 2024; 21:231-243. [PMID: 38317554 PMCID: PMC10992630 DOI: 10.14245/ns.2347118.559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 12/08/2023] [Accepted: 12/16/2023] [Indexed: 02/07/2024] Open
Abstract
OBJECTIVE To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters. METHODS Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions. RESULTS Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO. CONCLUSION Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
Collapse
Affiliation(s)
- Xin Lv
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yelidana Nuertai
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Qiwei Wang
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Di Zhang
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Xumin Hu
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jiabao Liu
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ziliang Zeng
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Renyuan Huang
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Zhihao Huang
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Qiancheng Zhao
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Wenpeng Li
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Zhilei Zhang
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Liangbin Gao
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
Lu T, Sun Z, Xia H, Qing J, Rashad A, Lu Y, He X. Comparing the osteogenesis outcomes of different lumbar interbody fusions (A/O/X/T/PLIF) by evaluating their mechano-driven fusion processes. Comput Biol Med 2024; 171:108215. [PMID: 38422963 DOI: 10.1016/j.compbiomed.2024.108215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/20/2024] [Accepted: 02/25/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND In lumbar interbody fusion (LIF), achieving proper fusion status requires osteogenesis to occur in the disc space. Current LIF techniques, including anterior, oblique, lateral, transforaminal, and posterior LIF (A/O/X/T/PLIF), may result in varying osteogenesis outcomes due to differences in biomechanical characteristics. METHODS A mechano-regulation algorithm was developed to predict the fusion processes of A/O/X/T/PLIF based on finite element modeling and iterative evaluations of the mechanobiological activities of mesenchymal stem cells (MSCs) and their differentiated cells (osteoblasts, chondrocytes, and fibroblasts). Fusion occurred in the grafting region, and each differentiated cell type generated the corresponding tissue proportional to its concentration. The corresponding osteogenesis volume was calculated by multiplying the osteoblast concentration by the grafting volume. RESULTS TLIF and ALIF achieved markedly greater osteogenesis volumes than did PLIF and O/XLIF (5.46, 5.12, 4.26, and 3.15 cm3, respectively). Grafting volume and cage size were the main factors influencing the osteogenesis outcome in patients treated with LIF. A large grafting volume allowed more osteoblasts (bone tissues) to be accommodated in the disc space. A small cage size reduced the cage/endplate ratio and therefore decreased the stiffness of the LIF. This led to a larger osteogenesis region to promote osteoblastic differentiation of MSCs and osteoblast proliferation (bone regeneration), which subsequently increased the bone fraction in the grafting space. CONCLUSION TLIF and ALIF produced more favorable biomechanical environments for osteogenesis than did PLIF and O/XLIF. A small cage and a large grafting volume improve osteogenesis by facilitating osteogenesis-related cell activities driven by mechanical forces.
Collapse
Affiliation(s)
- Teng Lu
- Department of Orthopaedics, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, Shaanxi Province, China
| | - Zhongwei Sun
- Department of Engineering Mechanics, School of Civil Engineering, Southeast University, Nanjing, Jiangsu Province, China
| | - Huanhuan Xia
- China Science and Technology Exchange Center, Beijing, China
| | - Jie Qing
- Department of Orthopaedics, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, Shaanxi Province, China
| | - Abdul Rashad
- Department of Orthopaedics, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, Shaanxi Province, China
| | - Yi Lu
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Xijing He
- Department of Orthopaedics, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, Shaanxi Province, China.
| |
Collapse
|
8
|
Song Z, Zhang Z, Zheng J, Zhang K, Wang F, Ran M, Luo J. Short-term and mid-term evaluation of three types of minimally invasive lumbar fusion surgery for treatment of L4/L5 degenerative spondylolisthesis. Sci Rep 2024; 14:4320. [PMID: 38383595 PMCID: PMC10881486 DOI: 10.1038/s41598-024-54970-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Accepted: 02/19/2024] [Indexed: 02/23/2024] Open
Abstract
This was a single-centre retrospective study. Minimally invasive techniques for transforaminal lumbar interbody fusion (MIS-TLIF), oblique lumbar interbody fusion (OLIF), and percutaneous endoscopic transforaminal lumbar interbody fusion (Endo-TLIF) have been extensively used for lumbar degenerative diseases. The present study analyses the short-term and mid-term clinical effects of the above three minimally invasive techniques on L4/L5 degenerative spondylolisthesis. In this retrospective study, 98 patients with L4/L5 degenerative spondylolisthesis received MIS-TLIF, 107 received OLIF, and 114 received Endo-TLIF. All patients were followed up for at least one year. We compared patient data, including age, sex, body mass index (BMI), Oswestry disability index (ODI), visual analogue scale of low back pain (VAS-B), visual analogue scale of leg pain (VAS-L), surgical time, blood loss, drainage volume, hospital stay, complications, and neurological status. Moreover, we performed imaging evaluations, including lumbar lordosis angle (LLA), disc height (DH) and intervertebral fusion status. No significant differences were noted in age, sex, BMI, preoperative ODI, preoperative VAS-B, preoperative VAS-L, preoperative LLA, or preoperative DH. Patients who underwent OLIF had significantly decreased blood loss, a lower drainage volume, and a shorter hospital stay than those who underwent MIS-TLIF or Endo-TLIF (P < 0.05). The VAS-B in the OLIF group significantly decreased compared with in the MIS-TLIF and Endo-TLIF groups at 6 and 12 months postoperatively (P < 0.05). The VAS-L in the Endo-TLIF group significantly decreased compared with that in the MIS-TLIF and OLIF groups at 6 months postoperatively (P < 0.05). The ODI in the OLIF group was significantly better than that in the MIS-TLIF and Endo-TLIF groups at 6 months postoperatively (P < 0.05). No statistically significant differences in the incidence of complications and healthcare cost were found among the three groups. Follow-up LLA and DH changes were significantly lower in the OLIF group than in the other groups (P < 0.05). The intervertebral fusion rate was significantly higher in the OLIF group than in the other groups at 6 and 12 months postoperatively (P < 0.05). In conclusion, while MIS-TLIF, OLIF, and Endo-TLIF techniques can effectively treat patients with L4/5 degenerative spondylolisthesis, OLIF has more benefits, including less operative blood loss, a shorter hospital stay, a smaller drainage volume, efficacy for back pain, effective maintenance of lumbar lordosis angle and disc height, and a higher fusion rate. OLIF should be the preferred surgical treatment for patients with L4/5 degenerative spondylolisthesis.
Collapse
Affiliation(s)
- Zhaojun Song
- Spine Surgery Department of Suining Central Hospital, Sichuan, People's Republic of China
| | - Zhi Zhang
- Spine Surgery Department of Suining Central Hospital, Sichuan, People's Republic of China
| | - Jiazhuang Zheng
- Spine Surgery Department of Suining Central Hospital, Sichuan, People's Republic of China
| | - Kai Zhang
- Operation Room of Suining Central Hospital, Sichuan, People's Republic of China
| | - Fandong Wang
- Spine Surgery Department of Suining Central Hospital, Sichuan, People's Republic of China
| | - Maobo Ran
- Spine Surgery Department of Suining Central Hospital, Sichuan, People's Republic of China
| | - Juan Luo
- Medical Record Department of Suining Central Hospital, Sichuan, People's Republic of China.
| |
Collapse
|
9
|
Wu J, Miao J, Chen G, Xu H, Wen W, Xu H, Liu L. Finite element biomechanical analysis of 3D printed intervertebral fusion cage in osteoporotic population. BMC Musculoskelet Disord 2024; 25:129. [PMID: 38347518 PMCID: PMC10860281 DOI: 10.1186/s12891-024-07221-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 01/21/2024] [Indexed: 02/15/2024] Open
Abstract
OBJECTIVE To study the biomechanical characteristics of each tissue structure when using different 3D printing Cage in osteoporotic patients undergoing interbody fusion. METHODS A finite element model of the lumbar spine was reconstructed and validated with regarding a range of motion and intervertebral disc pressure from previous in vitro studies. Cage and pedicle screws were implanted and part of the lamina, spinous process, and facet joints were removed in the L4/5 segment of the validated mode to simulate interbody fusion. A 280 N follower load and 7.5 N·m moment were applied to different postoperative models and intact osteoporotic model to simulate lumbar motion. The biomechanical characteristics of different models were evaluated by calculating and analyzing the range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment. RESULTS After rigid fixation, the range of motion of the fixed segment of model A-C decreased significantly, which was much smaller than that of the osteoporotic model. And with the increase of the axial area of the interbody fusion cages, the fixed segment of model A-C tended to be more stable. The range of motion and intradiscal pressure of the spinal models with different interbody fusion cages were higher than those of the complete osteoporosis model, but there was no significant difference between the postoperative models. On the other hand, the L5 upper endplate stress and screw-rod system stress of model A-C show a decreasing trend in different directions of motion. The stress of the endplate is the highest during flexion, which can reach 40.5 MPa (model A). The difference in endplate stress between models A-C was the largest during lateral bending. The endplate stress of models A and B was 150.5% and 140.9% of that of model C, respectively. The stress of the screw-rod system was the highest during lateral bending (model A, 102.0 MPa), which was 108.4%, 102.4%, 110.4%, 114.2% of model B and 158.5%, 110.1%, 115.8%, 125.4% of model C in flexion, extension, lateral bending, and rotation, respectively. CONCLUSIONS For people with osteoporosis, no matter what type of cage is used, good immediate stability can be achieved after surgery. Larger cage sizes provide better fixation without significantly increasing ROM and IDP in adjacent segments, which may contribute to the development of ASD. In addition, larger cage sizes can disperse endplate stress and reduce stress concentration, which is of positive significance in preventing cage subsidence after operation. The cage and screw rod system establish a stress conduction pathway on the spine, and a larger cage greatly enhances the stress-bearing capacity of the front column, which can better distribute the stress of the posterior spine structure and the stress borne by the posterior screw rod system, reduce the stress concentration phenomenon of the nail rod system, and avoid exceeding the yield strength of the material, resulting in the risk of future instrument failure.
Collapse
Affiliation(s)
- Jincheng Wu
- Department of Emergency Trauma Surgery, The Second Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China, 48 Baishuitang Road, Longhua District, 571700
| | - Jun Miao
- Tianjin Hospital, Tianjin University, Tianjin, China
| | | | - Hanpeng Xu
- Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Wangqiang Wen
- The First Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China
| | - Haoxiang Xu
- The Second People's Hospital of Hefei, Hefei, Anhui, China
| | - Lizhu Liu
- Department of Emergency Trauma Surgery, The Second Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China, 48 Baishuitang Road, Longhua District, 571700.
| |
Collapse
|
10
|
Xu Z, Zheng Q, Zhang L, Chen R, Li Z, Xu W. Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis. BMC Musculoskelet Disord 2024; 25:97. [PMID: 38279094 PMCID: PMC10821608 DOI: 10.1186/s12891-024-07204-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 01/14/2024] [Indexed: 01/28/2024] Open
Abstract
BACKGROUND Finite element analysis (FEA) was performed to investigate the biomechanical differences between different adjunct fixation methods for oblique lumbar interbody fusion (OLIF) and to further analyze its effect on adjacent segmental degeneration. METHODS We built a single-segment (Si-segment) finite element model (FEM) for L4-5 and a double-segment (Do-segment) FEM for L3-5. Each complete FEM was supplemented and modified, and both developed two surgical models of OLIF with assisted internal fixation. They were OLIF with posterior bilateral percutaneous pedicle screw (TINA system) fixation (OLIF + BPS) and OLIF with lateral plate system (OLIF + LPS). The range of motion (ROM) and displacement of the vertebral body, cage stress, adjacent segment disc stress, and spinal ligament tension were recorded for the four models during flexion/extension, right/left bending, and right/left rotation by applying follower load. RESULTS For the BPS and LPS systems in the six postures of flexion, extension, right/left bending, and right/left rotation, the ROM of L4 in the Si-segment FEM were 0.32°/1.83°, 0.33°/1.34°, 0.23°/0.47°, 0.24°/0.45°, 0.33°/0.79°, and 0.34°/0.62°; the ROM of L4 in the Do-segment FEM were 0.39°/2.00°, 0.37°/1.38°, 0.23°/0.47°, 0.21°/0.44°, 0.33°/0.57°, and 0.31°/0.62°, and the ROM of L3 in the Do-segment FEM were 6.03°/7.31°, 2.52°/3.50°, 4.21°/4.38°, 4.21°/4.42°, 2.09°/2.32°, and 2.07°/2.43°. BPS system had less vertebral displacement, less cage maximum stress, and less spinal ligament tension in Si/Do-segment FEM relative to the LPS system. BPS system had a smaller upper adjacent vertebral ROM, greater intervertebral disc stress in terms of left and right bending as well as left and right rotation compared to the LPS system in the L3-4 of the Do-segment FEM. There was little biomechanical difference between the same fixation system in the Si/Do-segment FEM. CONCLUSIONS Our finite element analysis showed that compared to OLIF + LPS, OLIF + BPS (TINA) is more effective in reducing interbody stress and spinal ligament tension, and it better maintains the stability of the target segment and provides a better fusion environment to resist cage subsidence. However, OLIF + BPS (TINA) may be more likely to cause adjacent segment degeneration than OLIF + LPS.
Collapse
Affiliation(s)
- Zhengquan Xu
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China
| | - Qingcong Zheng
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China
| | - Liqun Zhang
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China
| | - Rongsheng Chen
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China
| | - Zhechen Li
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China
| | - Weihong Xu
- Department of Spinal Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China.
| |
Collapse
|
11
|
Pradeep K, Pal B. Effects of open and minimally invasive Transforaminal Lumbar Interbody Fusion (TLIF) surgical techniques on mechanical behaviour of fused L3-L4 FSU: A comparative finite element study. Med Eng Phys 2024; 123:104084. [PMID: 38365336 DOI: 10.1016/j.medengphy.2023.104084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 11/30/2023] [Accepted: 12/10/2023] [Indexed: 02/18/2024]
Abstract
For predicting the biomechanical effects of the fusion procedure, finite element (FE) analysis is widely used as a preclinical tool. Although several FE studies examined the efficacies of various fusion surgical techniques, comparative studies on Open and minimally invasive (MIS) transforaminal lumbar interbody fusion (TLIF) procedures incorporating a follower coordinate system have not been investigated yet. The current FE study evaluates the ranges of motion (ROM) and load distributions of Open-TLIF and MIS-TLIF implanted models, under physiological loading such as compression, flexion, extension and lateral bending. The most noteworthy finding from the investigation is that both the fusion procedures significantly reduced the ROMs of the implanted segment (L3-L4) and full model (L1-L5) by at least 89 % and 44 %, respectively, compared to the intact model. For all loading situations, over 95 % of the implanted models' cancellous bone volume was subjected to von Mises strains ranging from 0.0003 to 0.005. The maximum von Mises strain was observed to be localized on a small amount of cancellous bone volume (<5 %). The likelihood of adjacent segment degeneration is higher in the case of MIS-TLIF due to the higher stress (22-53 MPa) and strain (0.018-0.087) noticed on the upper facet of the L3 vertebra.
Collapse
Affiliation(s)
- Kishore Pradeep
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India
| | - Bidyut Pal
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India.
| |
Collapse
|
12
|
Bokov A, Kalinina S, Khaltyrov M, Pavlova S, Bulkin A. Supplementary posterior fusion in patients operated on employing TLIF may decrease the instrumentation failure rate. Front Surg 2023; 10:1259946. [PMID: 38186390 PMCID: PMC10766769 DOI: 10.3389/fsurg.2023.1259946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/11/2023] [Indexed: 01/09/2024] Open
Abstract
Background It is supposed that additional posterior fusion may provide additional stability of the pedicle screw; however, the clinical impact of additional posterior fusion in patients treated with TLIF remains uncertain. The objective of this study is to assess the clinical efficacy of circumferential fusion in patients treated with TLIF. Materials and methods This is a single-center retrospective evaluation of consecutive 179 patients with degenerative lumbar stenosis and instability of spinal segments. Patients with axial pain and neurogenic claudication or radiculopathy associated with spinal stenosis were enrolled during the period from 2012 to 2018. Transforaminal lumbar interbody fusion (TLIF) with a single cage was used to treat patients. In 118 cases a supplementary posterior fusion was made. The duration of follow-up accounted for 24 months, logistic regression analysis was used to assess factors that influence the complication rate. Results The rate of pedicle screw loosening was growing with radiodensity getting decreased and was more frequent in patients with two level fusion. An increase in pedicle screw loosening rate correlated with anterior nonunion Tan 2 and 3 grade while both posterior complete and incomplete fusion resulted in a decline in the complication rate. Lumbosacral fusion, bilateral facet joints` resection and laminectomy turned out to be insignificant factors. The overall goodness of fit of the estimated general multivariate model was χ2 = 87.2230; P < 0.0001. To confirm clinical relevance of those findings, a univariate logistic regression was performed to assess the association between clinically significant pedicle screw instability and posterior fusion in patients operated on employing TLIF. The results of logistic regression analysis demonstrate that additional posterior fusion may decrease the rate of instrumentation failure that requires revision surgery in patients treated with TLIF [B0 = 1.314321; B1 = -3.218279; p = 0.0023; OR = 24.98507; 95% CI (3.209265; 194.5162), the overall goodness of fit of the estimated regression was χ2 = 22.29538, p = <0.0001]. Conclusion Circumferential fusion in patients operated on employing TLIF is associated with a decline in the rate of pedicle screw loosening detected by CT imaging and clinically significant instrumentation failure.
Collapse
Affiliation(s)
- Andrey Bokov
- Institute of Traumatology and Orthopedics, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Svetlana Kalinina
- Department of Neurosurgery, Institute of Traumatology and Orthopedics, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Mingiyan Khaltyrov
- Department of Neurosurgery, Institute of Traumatology and Orthopedics, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Svetlana Pavlova
- Department of Neurosurgery, Institute of Traumatology and Orthopedics, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Anatoliy Bulkin
- Institute of Traumatology and Orthopedics, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| |
Collapse
|
13
|
Liu J, Geng Z, Wang J, Zhang Z, Zhang X, Miao J. Biomechanical differences between two different shapes of oblique lumbar interbody fusion cages on whether to add posterior internal fixation system: a finite element analysis. J Orthop Surg Res 2023; 18:962. [PMID: 38093357 PMCID: PMC10720077 DOI: 10.1186/s13018-023-04461-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 12/10/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND Oblique lateral lumbar fusion (OLIF) is widely used in spinal degeneration, deformity and other diseases. The purpose of this study was to investigate the biomechanical differences between two different shapes of OLIF cages on whether to add posterior internal fixation system, using finite element analysis. METHODS A complete three-dimensional finite element model is established and verified for L3-L5. Surgical simulation was performed on the verified model, and the L4-L5 was the surgical segment. A total of the stand-alone group (Model A1, Model B1) and the BPSF group (Model A2, Model B2) were constructed. The four OLIF surgical models were: A1. Stand-alone OLIF with a kidney-shaped Cage; B1. Stand-alone OLIF with a straight cage; A2. OLIF with a kidney-shaped cage + BPSF; B2. Stand-alone OLIF with a straight cage + BPSF, respectively. The differences in the range of motion of the surgical segment (ROM), equivalent stress peak of the cage (ESPC), the maximum equivalent stress of the endplate (MESE) and the maximum stress of the internal fixation (MSIF) were compared between different models. RESULTS All OLIF surgical models showed that ROM declines between 74.87 and 96.77% at L4-L5 operative levels. The decreasing order of ROM was Model A2 > Model B2 > Model A1 > Model A2. In addition, the ESPC and MESE of Model A2 are smaller than those of other OLIF models. Except for the left-bending position, the MSIF of Model B2 increased by 1.51-16.69% compared with Model A2 in each position. The maximum value of MESE was 124.4 Mpa for Model B1 in the backward extension position, and the minimum value was 7.91 Mpa for Model A2 in the right rotation. Stand-alone group showed significantly higher ROMs and ESPCs than the BPSF group, with maximum values of 66.66% and 70.59%. For MESE, the BPSF group model can be reduced by 89.88% compared to the stand-alone group model. CONCLUSIONS Compared with the traditional straight OLIF cage, the kidney-shaped OLIF cage can further improve the stability of the surgical segment, reduce ESPC, MESE and MSIF, and help to reduce the risk of cage subsidence.
Collapse
Affiliation(s)
- Jianchao Liu
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Ziming Geng
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Jian Wang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Zepei Zhang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Xingze Zhang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Jun Miao
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China.
| |
Collapse
|
14
|
Wang J, Geng Z, Ma X, Zhang Z, Miao J. A comparative analysis of using cage acrossing the vertebral ring apophysis in normal and osteoporotic models under endplate injury: a finite element analysis. Front Bioeng Biotechnol 2023; 11:1263751. [PMID: 38026854 PMCID: PMC10664026 DOI: 10.3389/fbioe.2023.1263751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/23/2023] [Indexed: 12/01/2023] Open
Abstract
Background: Lateral lumbar fusion is an advanced, minimally invasive treatment for degenerative lumbar diseases. It involves different cage designs, primarily varying in size. This study aims to investigate the biomechanics of the long cage spanning the ring apophysis in both normal and osteoporotic models, considering endplate damage, using finite element analysis. Methods: Model 1 was an intact endplate with a long cage spanning the ring apophysis. Model 2 was an endplate decortication with a long cage spanning the ring apophysis. Model 3 was an intact endplate with a short cage. Model 4 was an endplate decortication with a short cage. On the basis of the four original models, further osteoporosis models were created, yielding a total of eight finite element models. The provided passage delineates a study that elucidates the utilization of finite element analysis as a methodology to simulate and analyze the biomechanical repercussions ensuing from the adoption of two distinct types of intervertebral fusion devices (cages) within the physiological framework of a human body. Results: The investigation found no appreciable changes between Models 1 and 2 in the range of motion at the fixed and neighboring segments, the L3-4 IDP, screw-rod stress, endplate stress, or stress on the trabecular bone of the L5. Increases in these stresses were seen in models 3 and 4 in the ranges of 0.4%-676.1%, 252.9%-526.9%, 27.3%-516.6%, and 11.4%-109.3%, respectively. The osteoporotic models for scenarios 3 and 4 exhibit a similar trend to their respective normal bone density models, but these osteoporotic models consistently have higher numerical values. In particular, except for L3-4 IDP, the maximum values of these parameters in osteoporotic Models 3 and 4 were much higher than those in normal bone quality Models 1 and 2, rising by 385.3%, 116%, 435.1%, 758.3%, and 786.1%, respectively. Conclusion: Regardless of endplate injury or osteoporosis, it is advised to utilize a long cage that is 5 mm longer on each side than the bilateral pedicles because it has good biomechanical features and may lower the likelihood of problems after surgery. Additionally, using Long cages in individuals with osteoporosis may help avoid adjacent segment disease.
Collapse
Affiliation(s)
| | | | | | - Zepei Zhang
- Tianjin Hospital of Tianjin University, Tianjin, China
| | - Jun Miao
- Tianjin Hospital of Tianjin University, Tianjin, China
| |
Collapse
|
15
|
Zhang S, Zhang Y, Huang L, Zhang S, Lu C, Liu Z, Kang C, Wang Z. Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis. Sci Rep 2023; 13:17116. [PMID: 37816744 PMCID: PMC10564781 DOI: 10.1038/s41598-023-43399-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 09/22/2023] [Indexed: 10/12/2023] Open
Abstract
Multi-segmental lumbar degenerative disease, including intersegmental disc degeneration, is found in clinical practice. Controversy still exists regarding the treatment for cross-segment degeneration. Oblique Lateral Interbody Fusion (OLIF) with several internal fixations was used to treat cross-segment lumbar degenerative disease. A whole lumbar spine model was extracted from CT images of the whole lumbar spine of patients with lumbar degeneration. The L2-3 and L4-5 intervertebral spaces were fused with OLIF using modeling software, the Pedicle screws were performed on L2-3 and L4-5, and different internal fixations were performed on L3-4 in Finite Element (FE) software. Among the six 10 Nm moments of different directions, the L3-4 no surgery (NS) group had the relatively largest Range of Motion (ROM) in the whole lumbar spine, while the L2-5 Long segmental fixation (LSF)group had the smallest ROM and the other groups had similar ROM. The ROM in the L1-2 and L5-S1 was relatively close in the six group models, and the articular cartilage stress and disc stress on the L1-2 and L5-S1 were relatively close. In contrast, the L3-4 ROM differed relatively greatly, with the LSF ROM the smallest and the NS ROM the largest, and the L3-4 Coflex (Coflex) group more active than the L3-4 Bacfuse (Bacfuse) group and the L3-4 translaminar facet screw fixation (TFSF) group. The stress on the articular cartilage and disc at L3-4 was relatively greater in the NS disc and articular cartilage, and greater in the Coflex group than in the Bacfuse and TFSF groups, with the greatest stress on the internal fixation in the TFSF group, followed by the Coflex group, and relatively similar stress in the Bacfuse, LSF, and NS groups. In the TFSF group, the stress on the internal fixation was greater than the yield strength among different directional moments of 10 Nm, which means it is unsuitable to be an internal fixation. The LSF group had the greatest overall ROM, which may lead to postoperative low back discomfort. The NS group has the greatest overall ROM, but its increased stress on the L3-4 disc and articular cartilage may lead to accelerated degeneration of the L3-4 disc and articular cartilage. The Coflex and Bacfuse groups had a reduced L3-4 ROM but a greater stress on disc compared to the LSF group, which may lead to disc degeneration in the long term. However, their stress on the articular cartilage was relatively low. Coflex and Bacfuse can still be considered better surgical options.
Collapse
Affiliation(s)
- Shuyi Zhang
- Department of Orthopedics, Fuzhou Second Hospital, Fuzhou, 350007, Fujian, China
- Department of Spine Surgery, Affiliated Hospital of Chengde Medical College, Chengde, 067000, Hebei, China
| | - Yilong Zhang
- Department of Spine Surgery, Affiliated Hospital of Chengde Medical College, Chengde, 067000, Hebei, China
| | - Licai Huang
- Department of Orthopedics, Fuzhou Second Hospital, Fuzhou, 350007, Fujian, China
| | - Shuao Zhang
- School of Civil Engineering, Lanzhou University of Technology, Lanzhou, 730000, Gansu, China
| | - Chenshui Lu
- Department of Foreign Languages, Fu Zhou University, Fuzhou, 350100, Fujian, China
| | - Zhengpeng Liu
- Department of Spine Surgery, Affiliated Hospital of Chengde Medical College, Chengde, 067000, Hebei, China
| | - Chan Kang
- Department of Orthopedics, Chungnam National University Hospital, Daejeon, 35015, Republic of Korea
| | - Zhao Wang
- Department of Orthopedics, Chungnam National University Hospital, Daejeon, 35015, Republic of Korea.
| |
Collapse
|
16
|
Hao J, Tang X, Jiang N, Wang H, Jiang J. Biomechanical stability of oblique lateral interbody fusion combined with four types of internal fixations: finite element analysis. Front Bioeng Biotechnol 2023; 11:1260693. [PMID: 37818236 PMCID: PMC10561304 DOI: 10.3389/fbioe.2023.1260693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 09/04/2023] [Indexed: 10/12/2023] Open
Abstract
Objective: Using finite element analysis to identify the optimal internal fixation method for oblique lateral lumbar interbody fusion (OLIF), providing guidance for clinical practice. Methods: A finite element model of the L4 - L5 segment was created. Five types of internal fixations were simulated in the generated L4-L5 finite element (FE) model. Then, six loading scenarios, i.e., flexion, extension, left-leaning, right-leaning, rotate left, and rotate right, were simulated in the FE models with different types of fixations. The biomechanical stability of the spinal segment after different fixations was investigated. Results: Regarding the range of motion (ROM) of the fused segment, OLIF + Bilateral Pedicle Screws (BPS) has a maximum ROM of 1.82° during backward bending and the smallest ROM in all directions of motion compared with other models. In terms of the von Mises stress distribution on the cage, the average stress on every motion direction of OLIF + BPS is about 17.08MPa, and of OLIF + Unilateral Vertebral Screw - Pedicle Screw (UVS-PS) is about 19.29 MPa. As for the von Mises stress distribution on the internal fixation, OLIF + BPS has the maximum internal fixator stress in left rotation (31.85 MPa) and OLIF + Unilateral Pedicle Screw (UPS) has the maximum internal fixator stress in posterior extension (76.59 MPa). The data of these two models were smaller than those of other models. Conclusion: OLIF + BPS provides the greatest biomechanical stability, OLIF + UPS has adequate biomechanical stability, OLIF + UVS-PS is inferior to OLIF + UPS synthetically, and OLIF + Double row vertical screw (DRVS) and Individual OLIF (IO) do not present significant obvious advantages.
Collapse
Affiliation(s)
- Jiayu Hao
- Department of Spine Surgery, Dalian Municipal Central Hospital, Dalian University of Technology, Dalian, China
| | - XianSheng Tang
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
| | - Nizhou Jiang
- Department of Spine Surgery, Dalian Municipal Central Hospital, Dalian University of Technology, Dalian, China
| | - Hong Wang
- Department of Spine Surgery, Dalian Municipal Central Hospital, Dalian University of Technology, Dalian, China
| | - Jian Jiang
- Department of Spine Surgery, Dalian Municipal Central Hospital, Dalian University of Technology, Dalian, China
| |
Collapse
|
17
|
Xu J, Yin Z, Li Y, Xie Y, Hou J. Clinic choice of long or short segment pedicle screw-rod fixation in the treatment of thoracolumbar burst fracture: From scan data to numerical study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3756. [PMID: 37448112 DOI: 10.1002/cnm.3756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 06/22/2023] [Accepted: 07/01/2023] [Indexed: 07/15/2023]
Abstract
Based on computerized tomography scanning images of human lumbar vertebrae, finite element (FE) analysis is performed to predict the stress of pedicle screws, rods, and fractured vertebra as well as the displacement of fractured vertebra after internal fixation treatment of thoracolumbar burst fracture. A three-dimensional FE model of L1-L5 lumbar vertebrae with L3 burst fracture has been established and four fixation methods, namely, short segment cross- and trans-injured vertebrae, long segment cross- and trans-injured vertebrae fixations, have been adopted to perform posterior pedicle fixation. The stress distributions of the screws, rods, and fractured vertebra and the total deformation of the fractured vertebra are investigated under six different physiological motions. From the view of the stress on the screw-rod system and the deformation of the fractured vertebral body, the long segment cross-injured vertebra fixation has the best mechanical performance, followed by the long segment trans-injured vertebra fixation, and then the short segment fixation trans-injured vertebra. The short segment fixation cross-injured vertebra performs the worst. Among the six motions, the forward flexion movement has the greatest impact on the screw-rod system and the fractured vertebra. However, the rotation motion greatly affects the stress of the screw in the long segment fixation. This indicates that the longer the fixed segment is, the more susceptible it is to human rotation. Thus, for patients with severe fracture, the long segment cross-injured vertebra is preferred. On the contrary, the short segment trans-injured vertebra fixation is optimal.
Collapse
Affiliation(s)
- Jiangping Xu
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Zhijun Yin
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Yang Li
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Yanqiu Xie
- People's Hospital of Jingshan, Jingshan Union Hospital of Huazhong University of Science and Technology, Jingmen, China
| | - Jiangping Hou
- People's Hospital of Jingshan, Jingshan Union Hospital of Huazhong University of Science and Technology, Jingmen, China
| |
Collapse
|
18
|
Wang J, Geng Z, Wu J, Liu J, Zhang Z, Miao J, Li R. Biomechanical properties of lumbar vertebral ring apophysis cage under endplate injury: a finite element analysis. BMC Musculoskelet Disord 2023; 24:695. [PMID: 37649054 PMCID: PMC10466841 DOI: 10.1186/s12891-023-06792-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 08/10/2023] [Indexed: 09/01/2023] Open
Abstract
OBJECTIVE This study aimed to compare the biomechanical properties of lumbar interbody fusion involving two types of cages. The study evaluated the effectiveness of the cage spanning the ring apophysis, regardless of the endplate's integrity. METHODS A finite element model of the normal spine was established and validated in this study. The validated model was then utilized to simulate Lateral Lumbar Interbody Fusion (LLIF) with posterior pedicle screw fixation without posterior osteotomy. Two models of interbody fusion cage were placed at the L4/5 level, and the destruction of the bony endplate caused by curetting the cartilaginous endplate during surgery was simulated. Four models were established, including Model 1 with an intact endplate and long cage spanning the ring apophysis, Model 2 with endplate decortication and long cage spanning the ring apophysis, Model 3 with an intact endplate and short cage, and Model 4 with endplate decortication and short cage. Analyzed were the ROM of the fixed and adjacent segments, screw rod system stress, interface stress between cage and L5 endplate, trabecular bone stress on the upper surface of L5, and intervertebral disc pressure (IDP) of adjacent segments. RESULTS There were no significant differences in ROM and IDP between adjacent segments in each postoperative model. In the short cage model, the range of motion (ROM), contact pressure between the cage and endplate, stress in L5 cancellous bone, and stress in the screw-rod system all exhibited an increase ranging from 0.4% to 79.9%, 252.9% to 526.9%, 27.3% to 133.3%, and 11.4% to 107%, respectively. This trend was further amplified when the endplate was damaged, resulting in a maximum increase of 88.6%, 676.1%, 516.6%, and 109.3%, respectively. Regardless of the integrity of the endplate, the long cage provided greater support strength compared to the short cage. CONCLUSIONS Caution should be exercised during endplate preparation and cage placement to maintain the endplate's integrity. Based on preoperative X-ray evaluation, the selection of a cage that exceeds the width of the pedicle by at least 5 mm (ensuring complete coverage of the vertebral ring) has demonstrated remarkable biomechanical performance in lateral lumbar interbody fusion procedures. By opting for such a cage, we expect a reduced occurrence of complications, including cage subsidence, internal fixation system failure, and rod fracture.
Collapse
Affiliation(s)
- Jian Wang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Ziming Geng
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Jincheng Wu
- The Second Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China
| | - Jianchao Liu
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Zepei Zhang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China
| | - Jun Miao
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China.
| | - Ruihua Li
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Rd, Hexi District, Tianjin, 300211, China.
| |
Collapse
|
19
|
Liu J, Gong X, Wang K, Li X, Zhang X, Sun J, Zhu Y, Ai Y, Ren J, Xiu J, Ji W. A comparison of the biomechanical properties of three different lumbar internal fixation methods in the treatment of lumbosacral spinal tuberculosis: finite element analysis. Sci Rep 2023; 13:11354. [PMID: 37443369 PMCID: PMC10344955 DOI: 10.1038/s41598-023-32624-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 03/30/2023] [Indexed: 07/15/2023] Open
Abstract
There are various internal fixation methods in treating lumbosacral spinal tuberculosis. The study compared the stability and stress distribution in surrounding tissues/implants, such as discs, endplates and screw-rod internal fixation system, etc. when applying three different lumbar internal fixation methods to treat lumbosacral spinal tuberculosis. A finite element model was constructed and validated. The spinal stability was restored using three methods: a titanium cage with lateral double screw-rod fixation (group 1), autologous bone with posterior double screw-rod fixation (group 2), and a titanium cage with posterior double screw-rod fixation (group 3). For comparison, group 4 represented the intact L3-S1 spine. Finally, a load was applied, and the ranges of motion and Von Mises stresses in the cortical endplates, screw-rod internal fixation system and cortical bone around the screws in the different groups were recorded and analyzed. All six ranges of motion (flexion, extension, left/right lateral bending, left/right rotation) of the surgical segment were substantially lower in groups 1 (0.53° ~ 1.41°), 2 (0.68° ~ 1.54°) and 3 (0.55° ~ 0.64°) than in group 4 (4.48° ~ 10.12°). The maximum stress in the screw-rod internal fixation system was clearly higher in group 2 than in groups 1 and 3 under flexion, left/right lateral bending, and left/right rotation. However, in extension, group 1 had the highest maximum stress in the screw-rod internal fixation system. Group 2 had the lowest peak stresses in the cortical endplates in all directions. The peak stresses in the cortical bone around the screws were higher in group 1 and group 2 than in group 3 in all directions. Thus, titanium cage with posterior double screw-rod fixation has more advantages in immediate reconstruction of lumbosacral spinal stability and prevention of screw loosening.
Collapse
Affiliation(s)
- Jiantao Liu
- Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China.
| | - Xi Gong
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Kao Wang
- Medical School of Yan'an University, Yan'an, 716000, China
| | - Xingyuan Li
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Xiwei Zhang
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Jiajun Sun
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Yihan Zhu
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Yixiang Ai
- Xi'an Jiaotong University, Xi'an, 710049, China
| | - Jing Ren
- Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China
| | - Jintao Xiu
- Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China
| | - Wenchen Ji
- Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China
| |
Collapse
|
20
|
Zhong Y, Wang Y, Zhou H, Wang Y, Gan Z, Qu Y, Hua R, Chen Z, Chu G, Liu Y, Jiang W. Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis. Front Med (Lausanne) 2023; 10:1183683. [PMID: 37457575 PMCID: PMC10345158 DOI: 10.3389/fmed.2023.1183683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 06/09/2023] [Indexed: 07/18/2023] Open
Abstract
Objective The aim of this study was to verify the biomechanical properties of a newly designed angulated lateral plate (mini-LP) suited for two-level oblique lumbar interbody fusion (OLIF). The mini-LP is placed through the lateral ante-psoas surgical corridor, which reduces the operative time and complications associated with prolonged anesthesia and placement in the prone position. Methods A three-dimensional nonlinear finite element (FE) model of an intact L1-L5 lumbar spine was constructed and validated. The intact model was modified to generate a two-level OLIF surgery model augmented with three types of lateral fixation (stand-alone, SA; lateral rod screw, LRS; miniature lateral plate, mini-LP); the operative segments were L2-L3 and L3-L4. By applying a 500 N follower load and 7.5 Nm directional moment (flexion-extension, lateral bending, and axial rotation), all models were used to simulate human spine movement. Then, we extracted the range of motion (ROM), peak contact force of the bony endplate (PCFBE), peak equivalent stress of the cage (PESC), peak equivalent stress of fixation (PESF), and stress contour plots. Results When compared with the intact model, the SA model achieved the least reduction in ROM to surgical segments in all motions. The ROM of the mini-LP model was slightly smaller than that of the LRS model. There were no significant differences in surgical segments (L1-L2, L4-L5) between all surgical models and the intact model. The PCFBE and PESC of the LRS and the mini-LP fixation models were lower than those of the SA model. However, the differences in PCFBE or PESC between the LRS- and mini-LP-based models were not significant. The fixation stress of the LRS- and mini-LP-based models was significantly lower than the yield strength under all loading conditions. In addition, the variances in the PESF in the LRS- and mini-LP-based models were not obvious. Conclusion Our biomechanical FE analysis indicated that LRS or mini-LP fixation can both provide adequate biomechanical stability for two-level OLIF through a single incision. The newly designed mini-LP model seemed to be superior in installation convenience, and equally good outcomes were achieved with both LRS and mini-LP for two-level OLIF.
Collapse
Affiliation(s)
- Yuan Zhong
- Department of Orthopaedic Surgery, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, China
| | - Yujie Wang
- Department of Orthopaedic Surgery, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, China
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China
| | - Hong Zhou
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Yudong Wang
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Ziying Gan
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Yimeng Qu
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Runjia Hua
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Zhaowei Chen
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Genglei Chu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Yijie Liu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| | - Weimin Jiang
- Department of Orthopaedic Surgery, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, China
- Suzhou Medical College, Soochow University, Suzhou, Jiangsu Province, China
| |
Collapse
|
21
|
Wu W, Yu R, Hao H, Yang K, Jiao G, Liu H. Visible trephine-based foraminoplasty in PTED leads to asymmetrical stress changes and instability in the surgical and adjacent segments: a finite element analysis. J Orthop Surg Res 2023; 18:431. [PMID: 37312161 DOI: 10.1186/s13018-023-03916-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 06/08/2023] [Indexed: 06/15/2023] Open
Abstract
This study aimed to construct a multi-segment lumbar finite element model (FEM) of PTED surgery to analyze the changes in stress and ROM after visible trephine-based foraminoplasty. The CT scans of a 35-year-old healthy male were used to develop a multi-segment lumbar FEM with Mimic, Geomagic Studio, Hypermesh and MSC.Patran. Different foraminoplasty was performed on the model, and these were grouped into normal group (A), the ventral resection group (B), the apex resection group (C), the ventral + apex + isthmus resection group (D), and the SAP + isthmus + lateral recess resection group (E). A vertical load of 500N and a torque of 10N·M were applied to the upper surface of the L3 vertebral body to simulate the biomechanical characteristics under the motion of flexion, extension, lateral bending, and rotation. The von Mises stress maps of the intervertebral f, vertebral body, facet joints, and the ROM of the L3-S1 intervertebral disk were calculated and analyzed. The changes of peak stress on the vertebral body for each group were not significant in the same motion state. Significant stress differences were observed in the L4/5 intervertebral disks, while no obvious stress changes were observed for the L3/4 and L5/S1 intervertebral disks. The stress of the L3/4 and L5/S1 facet joints decreased after L4/5 foraminoplasty, while the stress of L4/5 facet joints displayed an overall increasing trend. Significant asymmetrical stress changes of bilateral facet joints were observed in all three segments, particularly during bilateral rotation movements. The ROM of L3-S1 gradually increased from Group A to Group E, especially during flexion, left lateral bending, and right rotation, with the highest elevation observed for the L45 ROM. Our FEM indicated that enlarged resection and exposure of the articular surface could lead to significant asymmetrical stress changes in the bilateral facet joints and ROM instability of the surgical and adjacent segments. These findings suggested that unnecessary and excessive resection should be avoided in PTED to reduce the incidence of low back pain and the risk of postsurgical degeneration.
Collapse
Affiliation(s)
- Wenliang Wu
- Department of Spine Surgery, Qilu Hospital of Shandong University, Wenhuaxi Road No.107, Jinan, 250012, People's Republic of China
- Department of Physician Training, Qilu Hospital of Shandong University, Jinan, People's Republic of China
| | - Ruixuan Yu
- Department of Spine Surgery, Qilu Hospital of Shandong University, Wenhuaxi Road No.107, Jinan, 250012, People's Republic of China
| | - Hongkai Hao
- Department of Spine Surgery, Qilu Hospital of Shandong University, Wenhuaxi Road No.107, Jinan, 250012, People's Republic of China
| | - Kaiyun Yang
- Institute of Stomatology, Qilu Hospital of Shandong University, Jinan, 250012, People's Republic of China
| | - Guangjun Jiao
- Department of Spine Surgery, Qilu Hospital of Shandong University, Wenhuaxi Road No.107, Jinan, 250012, People's Republic of China
| | - Haichun Liu
- Department of Spine Surgery, Qilu Hospital of Shandong University, Wenhuaxi Road No.107, Jinan, 250012, People's Republic of China.
| |
Collapse
|
22
|
Zhang R, Kahaer A, Niu H, Wang J, Jumahan A, Qiu Y, Guo H, Rexiti P. Biomechanical evaluation of the hybrid pedicle screw-cortical bone trajectory technique in transforaminal lumbar interbody fusion to adjacent segment degeneration-finite element analysis. BMC Musculoskelet Disord 2023; 24:409. [PMID: 37221546 DOI: 10.1186/s12891-023-06411-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 04/07/2023] [Indexed: 05/25/2023] Open
Abstract
BACKGROUND Transforaminal lumbar interbody fusion is an effective surgical treatment of intervertebral disk herniation. However, its clinical efficacy for adjacent segment disk degeneration (ASDD) after hybrid bilateral pedicle screw - bilateral cortical screw (pedicle screw at L4 and cortical bone trajectory screw at L5) and hybrid bilateral cortical screw - bilateral pedicle screw (bilateral cortical screw at L4 and bilateral pedicle screw at L5) remains undiscovered. Therefore, the aim of this study is to evaluate the effect of the hybrid bilateral pedicle screw - bilateral cortical screw and hybrid bilateral cortical screw - bilateral pedicle screw on the adjacent segment via a 3-dimensional (3D) finite element (FE) analysis. METHODS Four human cadaveric lumbar spine specimens were provided by the anatomy teaching and research department of Xinjiang Medical University. Four finite element models of L1-S1 lumbar spine segment were generated. For each of these, four lumbar transforaminal lumbar interbody fusion models at L4-L5 segment with the following instruments were created: hybrid bilateral pedicle screw - bilateral cortical screw, bilateral cortical screw - bilateral cortical screw (bilateral cortical screw at both L4 and L5 segments), bilateral pedicle screw - bilateral pedicle screw (bilateral pedicle screw at both L4 and L5 segments), and hybrid bilateral cortical screw - bilateral pedicle screw. A 400-N compressive load with 7.5 Nm moments was applied for the simulation of flexion, extension, lateral bending, and rotation. The range of motion of L3-L4 and L5-S1 segments and von Mises stress of the intervertebral disc at the adjacent segment were compared. RESULTS Hybrid bilateral pedicle screw - bilateral cortical screw has the lowest range of motion at L3-L4 segment in flexion, extension, and lateral bending, and the highest disc stress in all motions, while the range of motion at L5-S1 segment and disc stress was lower than bilateral pedicle screw - bilateral pedicle screw in flexion, extension, and lateral bending, and higher than bilateral cortical screw - bilateral cortical screw in all motions. The range of motion of hybrid bilateral cortical screw - bilateral pedicle screw at L3-L4 segment was lower than bilateral pedicle screw - bilateral pedicle screw and higher than bilateral cortical screw - bilateral cortical screw in flexion, extension, and lateral bending, and the range of motion at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in flexion, lateral bending, and axial rotation. The disc stress at L3-L4 segment was lowest and more dispersed in all motions, and the disc stress at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in lateral bending and axial rotation, but more dispersed. CONCLUSION Hybrid bilateral cortical screw - bilateral pedicle screw decreases the impact on adjacent segments after spinal fusion, reduces the iatrogenic injury to the paravertebral tissues, and provides throughout decompression of the lateral recess.
Collapse
Affiliation(s)
- Rui Zhang
- Second Clinical Medical College, Xinjiang Medical University, Urumqi, China
| | - Alafate Kahaer
- Department of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Urumqi, China
| | - Hanqian Niu
- Fifth Clinical Medical College, Xinjiang Medical University, Urumqi, China
| | - Jingwen Wang
- Second Clinical Medical College, Xinjiang Medical University, Urumqi, China
| | - Ayididaer Jumahan
- First Clinical Medical College, Xinjiang Medical University, Urumqi, China
| | - Yanning Qiu
- First Clinical Medical College, Xinjiang Medical University, Urumqi, China
| | - Hailong Guo
- Department of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Urumqi, China.
| | - Paerhati Rexiti
- Department of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Urumqi, China.
| |
Collapse
|
23
|
Cai P, Xi Z, Deng C, Li J, Zhang X, Zhou Y. Fixation-induced surgical segment's high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations. J Orthop Surg Res 2023; 18:371. [PMID: 37208705 DOI: 10.1186/s13018-023-03838-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 05/06/2023] [Indexed: 05/21/2023] Open
Abstract
BACKGROUND Adjacent segment disease (ASD) is a commonly reported complication after lumbar interbody fusion (LIF); changes in the mechanical environment play an essential role in the generation of ASD. Traditionally, fixation-induced high stiffness in the surgical segment was the main reason for ASD. However, with more attention paid to the biomechanical significance of posterior bony and soft structures, surgeons hypothesize that this factor may also play an important role in ASD. METHODS Oblique and posterior LIF operations have been simulated in this study. The stand-alone OLIF and OLIF fixed by bilateral pedicle screw (BPS) system have been simulated. The spinal process (the attachment point of cranial ligamentum complex) was excised in the PLIF model; the BPS system has also been used in the PLIF model. Stress values related to ASD have been computed under physiological body positions, including flexion, extension, bending, and axial rotations. RESULTS Compared to the stand-alone OLIF model, the OLIF model with BPS fixation suffers higher stress values under extension body position. However, there are no apparent differences under other loading conditions. Moreover, significant increases in stress values can be recorded in flexion and extension loading conditions in the PLIF model with posterior structures damage. CONCLUSIONS Fixation-induced surgical segment's high stiffness and the damage of posterior soft tissues together trigger a higher risk of ASD in patients with LIF operations. Optimizing BPS fixation methods and pedicle screw designs and reducing the range of posterior structures excision may be an effective method to reduce the risk of ASD.
Collapse
Affiliation(s)
- Ping Cai
- Department of Orthopedics, Lianyungang Hospital of Traditional Chinese Medicine, Lianyungang, Jiangsu, People's Republic of China
- Department of Orthopedics, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Zhieng Xi
- Department of Spine Surgery, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Chao Deng
- Department of Orthopedics, Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Jingchi Li
- Department of Spine Surgery, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Xiaoyu Zhang
- Department of Spine Surgery, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, Jiangsu, People's Republic of China
| | - Yingguang Zhou
- Department of Orthopedics, Lianyungang Hospital of Traditional Chinese Medicine, Lianyungang, Jiangsu, People's Republic of China.
| |
Collapse
|
24
|
Lee HJ, Lee SJ, Jung JM, Lee TH, Jeong C, Lee TJ, Jang JE, Lee JW. Biomechanical Evaluation of Lateral Lumbar Interbody Fusion with Various Fixation Options for Adjacent Segment Degeneration: A Finite Element Analysis. World Neurosurg 2023; 173:e156-e167. [PMID: 36775239 DOI: 10.1016/j.wneu.2023.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Accepted: 02/04/2023] [Indexed: 02/12/2023]
Abstract
OBJECTIVE Adjacent segment degeneration (ASD) is a common phenomenon after lumbar fusion. Lateral lumbar interbody fusion (LLIF) may provide an alternative treatment method for ASD. This study used finite element analysis to evaluate the biomechanical effects of LLIF with various fixation options and identify an optimal surgical strategy for ASD. METHODS A validated L1-S1 finite element model was modified for simulation. Six finite element models of the lumbar spine were created and were divided into group 1 (L4-5 posterior lumbar interbody fusion [PLIF] + L3-4 LLIF) and group 2 (L5-S1 PLIF + L4-5 LLIF). Each group consisted of 1) cage-alone, 2) cage + lateral screw fixation (LSF), and 3) cage + bilateral pedicle screw fixation (BPSF) models. The range of motion, intradiscal pressure, and facet loads of adjacent segments as well as interbody cage stress were analyzed. RESULTS The stress on the LLIF cage-superior endplate interface was highest in the cage-alone model followed by the cage + LSF model and cage + BPSF model. The increase in range of motion, intradiscal pressure, and facet loads at the adjacent segment was highest in the cage + BPSF model followed by the cage + LSF model and cage-alone model. However, the biomechanical effect on the adjacent segment seemed similar in the cage-alone and cage + LSF models. CONCLUSIONS LLIF with BPSF is recommended when performing LLIF surgery for ASD after L4-5 and L5-S1 PLIF. Considering cage subsidence and biomechanical effects on the adjacent segment, LLIF with LSF may be a suboptimal option for ASD surgery.
Collapse
Affiliation(s)
- Hyun Ji Lee
- Department of Biomedical Engineering, Inje University, Gimhae, Republic of Korea
| | - Sung-Jae Lee
- Department of Biomedical Engineering, Inje University, Gimhae, Republic of Korea
| | - Jong-Myung Jung
- Department of Neurosurgery, 9988 Joint & Spine Hospital, Seoul, Republic of Korea.
| | - Tae Hoon Lee
- Department of Orthopedic Surgery, 9988 Joint & Spine Hospital, Seoul, Republic of Korea
| | - Chandong Jeong
- Department of Orthopedic Surgery, 9988 Joint & Spine Hospital, Seoul, Republic of Korea
| | - Tae Jin Lee
- Department of Orthopedic Surgery, 9988 Joint & Spine Hospital, Seoul, Republic of Korea
| | - Ji-Eun Jang
- R&D Center, GS Medical Co., Ltd., Cheongju, Republic of Korea
| | - Jae-Won Lee
- R&D Center, GS Medical Co., Ltd., Cheongju, Republic of Korea
| |
Collapse
|
25
|
Saini S, Moger NM, Kumar M, Sarkar S, Mittal S, Ifthekar S, Ahuja K, Singh IV, Kandwal P. Biomechanical analysis of Instrumented decompression and Interbody fusion procedures in Lumbar spine: a finite element analysis study. Med Biol Eng Comput 2023:10.1007/s11517-023-02825-y. [DOI: 10.1007/s11517-023-02825-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 03/09/2023] [Indexed: 03/29/2023]
|
26
|
Fushimi K, Miyagawa T, Iwai C, Nozawa S, Iinuma N, Tanaka R, Shirai G, Tanahashi H, Yokoi T, Akiyama H. Transforaminal Lumbar Interbody Fusion with Double Banana Cages: Clinical Evaluations and Finite Element Model Analysis. Global Spine J 2023:21925682231165709. [PMID: 36944178 DOI: 10.1177/21925682231165709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023] Open
Abstract
STUDY DESIGN Clinical and basic study. OBJECTIVES This study aimed to investigate whether transforaminal lumbar interbody fusion (TLIF) using 2 banana-shaped cages leads to good clinical outcomes. METHODS First, we conducted a clinical study to compare outcomes among patients who underwent TLIF using different types or numbers of cages. Propensity matched patients in each group were reviewed. Thirty-four patients who underwent surgery with 2 bullet-shaped cages (group A), 34 with a banana-shaped cage (group B), and 34 with 2 banana-shaped cages (group C) were compared. Twelve months after the surgery, bony fusion and cage subsidence were evaluated. RESULTS The mean amount of cage subsidence was 14.9% in group A, 19.9% in group B, and 11.8% in group C. Subsidence in group B was significantly greater than that in group C (P < .01). Radiological bony fusion was not achieved in 2 cases in group B. Second, we performed a finite element model (FEM) analysis to determine the biomechanical stress of the vertebral endplate by comparing the single-banana cage construct with a double banana-shaped cage construct. FEM analysis showed that the maximum stress of the endplate in the single-cage model was 1.72-times greater than the maximum stress in the double-cage model. Furthermore, the maximal stress in the single-cage model was significantly higher than in the double-cage model during lumbar extension and side bending. CONCLUSION This study showed that TLIF with double banana-shaped cages led to good clinical outcomes with less cage subsidence, probably because of decreased mechanical stress on the vertebral endplate.
Collapse
Affiliation(s)
- Kazunari Fushimi
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Takaki Miyagawa
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Chizuo Iwai
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Satoshi Nozawa
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Nobuki Iinuma
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
| | - Ryo Tanaka
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
| | - Goshi Shirai
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
| | - Hiroyuki Tanahashi
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
| | - Tatsuo Yokoi
- Department of Orthopaedic Surgery, Spine Surgery Center, Gifu Prefectural General Medical Center, Gifu, Japan
| | - Haruhiko Akiyama
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| |
Collapse
|
27
|
Matos R, Fernandes PR, Matela N, Castro APG. Lumbar intervertebral disc segmentation for computer modeling and simulation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 230:107337. [PMID: 36634387 DOI: 10.1016/j.cmpb.2023.107337] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 11/23/2022] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND OBJECTIVE The present work had as its main objective the development of a method for localizing and automatically segmenting lumbar intervertebral discs (IVD) in 3D from magnetic resonance imaging (MRI), with the goal of supporting the generation of finite element (FE) models from actual lumbar spine anatomy, by providing accurate and personalized information on the shape of the patient's IVD. The extension of the method to allow performing separate segmentations of the IVD's two main structures - annulus fibrosus (AF) and nucleus pulposus (NP) - as well as automatically detecting degenerated IVD where this distinction is no longer possible was also an objective of the work. METHODS The method presented here evolves from 2D segmentations in the sagittal profile using Gabor filters towards 3D segmentations. It works by detecting the spine curves and intensity regions corresponding to IVD. As so, the 2D method from Zhu et al. (2013) was partially implemented, modified and adapted to 3D use, and then tested with eight spines from two separated online datasets. The 3D adaptation was achieved by using vertebral body segmentation masks to approximate the shape of the vertebrae and to adjust the spine curves accordingly. RESULTS The method showed average values of 85%, 83% and 96% for the Dice coefficient, sensitivity and specificity, respectively. The method correctly identified 65 of 68 (96%) IVD as either healthy or degenerated. The method's Dice coefficient is within the range of existing 3D IVD segmentation methods in the literature (81-92%). The method took on average 6-7 s to perform a full 3D segmentation, which is well within the range of the existing methods (2 s - 19 min). CONCLUSIONS The developed method can be used to generate accurate 3D models of the IVD based on MRI, with AF/NP distinction and detection of marked degeneration by comparing each IVD with the remaining spine levels. Further work shall improve the method towards distinguishing between specific levels of degeneration for clinically oriented FE modeling.
Collapse
Affiliation(s)
- R Matos
- Faculdade de Ciências da Universidade de Lisboa, 1749-016 Lisbon, Portugal
| | - P R Fernandes
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal
| | - N Matela
- Faculdade de Ciências da Universidade de Lisboa, 1749-016 Lisbon, Portugal; IBEB, Faculdade de Ciências da Universidade de Lisboa, 1749-016 Lisbon, Portugal
| | - A P G Castro
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisbon, Portugal; ESTSetúbal, Instituto Politécnico de Setúbal, 2910-761 Setúbal, Portugal.
| |
Collapse
|
28
|
Wu J, Feng Q, Yang D, Xu H, Wen W, Xu H, Miao J. Biomechanical evaluation of different sizes of 3D printed cage in lumbar interbody fusion-a finite element analysis. BMC Musculoskelet Disord 2023; 24:85. [PMID: 36726086 PMCID: PMC9890703 DOI: 10.1186/s12891-023-06201-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 01/27/2023] [Indexed: 02/03/2023] Open
Abstract
OBJECTIVE To study the biomechanical characteristics of various tissue structures of different sizes of 3D printed Cage in lumbar interbody fusion. METHODS A finite element model of normal spine was reconstructed and verified. Pedicle screws and Cage of different sizes were implanted in the L4/5 segment to simulate lumbar interbody fusion. The range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment were calculated and analyzed. RESULTS The range of motion and intervertebral disc pressure of the adjacent segment of each postoperative model were larger than those of the intact model, but there was not much difference between them. The stress of cage-endplate interface was also larger than that of the intact model. However, the difference is that the stress of the endplate and the screw-rod system has a tendency to decrease with the increase of the axial area of cage. CONCLUSIONS Cage with larger axial area in lumbar interbody fusion can reduce the stress of internal fixation system and endplate, but will not increase the range of motion and intervertebral disc pressure of adjacent segment. It has a certain effect in preventing the cage subsidence, internal fixation system failure and screw rod fracture.
Collapse
Affiliation(s)
- Jincheng Wu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| | - Qing Feng
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| | - Dongmei Yang
- grid.284723.80000 0000 8877 7471Southern Medical University, Guangzhou City, Guangdong China
| | - Hanpeng Xu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| | - Wangqiang Wen
- grid.443397.e0000 0004 0368 7493The First Affiliated Hospital of Hainan Medical University, Haikou City, Hainan China
| | - Haoxiang Xu
- The Second People’s Hospital of Hefei, Hefei, Anhui China
| | - Jun Miao
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| |
Collapse
|
29
|
Biomechanical Effect of Using Cement Augmentation to Prevent Proximal Junctional Kyphosis in Long-Segment Fusion: A Finite Element Study. J Med Biol Eng 2023. [DOI: 10.1007/s40846-023-00772-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
30
|
Pei B, Xu Y, Zhao Y, Wu X, Lu D, Wang H, Wu S. Biomechanical comparative analysis of conventional pedicle screws and cortical bone trajectory fixation in the lumbar spine: An in vitro and finite element study. Front Bioeng Biotechnol 2023; 11:1060059. [PMID: 36741751 PMCID: PMC9892841 DOI: 10.3389/fbioe.2023.1060059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 01/09/2023] [Indexed: 01/21/2023] Open
Abstract
Numerous screw fixation systems have evolved in clinical practice as a result of advances in screw insertion technology. Currently, pedicle screw (PS) fixation technology is recognized as the gold standard of posterior lumbar fusion, but it can also have some negative complications, such as screw loosening, pullout, and breakage. To address these concerns, cortical bone trajectory (CBT) has been proposed and gradually developed. However, it is still unclear whether cortical bone trajectory can achieve similar mechanical stability to pedicle screw and whether the combination of pedicle screw + cortical bone trajectory fixation can provide a suitable mechanical environment in the intervertebral space. The present study aimed to investigate the biomechanical responses of the lumbar spine with pedicle screw and cortical bone trajectory fixation. Accordingly, finite element analysis (FEA) and in vitro specimen biomechanical experiment (IVE) were performed to analyze the stiffness, range of motion (ROM), and stress distribution of the lumbar spine with various combinations of pedicle screw and cortical bone trajectory screws under single-segment and dual-segment fixation. The results show that dual-segment fixation and hybrid screw placement can provide greater stiffness, which is beneficial for maintaining the biomechanical stability of the spine. Meanwhile, each segment's range of motion is reduced after fusion, and the loss of adjacent segments' range of motion is more obvious with longer fusion segments, thereby leading to adjacent-segment disease (ASD). Long-segment internal fixation can equalize total spinal stresses. Additionally, cortical bone trajectory screws perform better in terms of the rotation resistance of fusion segments, while pedicle screw screws perform better in terms of flexion-extension resistance, as well as lateral bending. Moreover, the maximum screw stress of L4 cortical bone trajectory/L5 pedicle screw is the highest, followed by L45 cortical bone trajectory. This biomechanical analysis can accordingly provide inspiration for the choice of intervertebral fusion strategy.
Collapse
Affiliation(s)
- Baoqing Pei
- Beijing key laboratory for design and evaluation technology of advanced implantable & interventional medical devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yangyang Xu
- Beijing key laboratory for design and evaluation technology of advanced implantable & interventional medical devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yafei Zhao
- Aerospace center hospital, Beijing, China
| | - Xueqing Wu
- Beijing key laboratory for design and evaluation technology of advanced implantable & interventional medical devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China,*Correspondence: Xueqing Wu, ; Shuqin Wu,
| | - Da Lu
- Beijing key laboratory for design and evaluation technology of advanced implantable & interventional medical devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Haiyan Wang
- School of Basic Medicine, Inner Mongolia Medical University, Hohhot, China
| | - Shuqin Wu
- School of Big Data and Information, Shanxi College of Technology, Shanxi, China,*Correspondence: Xueqing Wu, ; Shuqin Wu,
| |
Collapse
|
31
|
Xue S, Wu T. Biomechanical Performances of an Oblique Lateral Interbody Fusion Cage in Models with Different Bone Densities: A Finite Element Analysis. Indian J Orthop 2023; 57:86-95. [PMID: 36660489 PMCID: PMC9789258 DOI: 10.1007/s43465-022-00775-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 11/07/2022] [Indexed: 11/18/2022]
Abstract
Study Design Finite element models of the L3-S1 vertebrae were reconstructed using computed tomography scans. Objective We compared the biomechanical performances of an oblique lateral interbody fusion (OLIF) cage in different bone density mode. Summary of Background Data Low bone density is an els.key factor limiting the use of stand-alone OLIF cage. Methods Four models-intact (M0), normal bone density with OLIF (M1), bone mass loss with OLIF (M2), and osteoporotic with OLIF (M3)-were created based on 3-dimensional scans. Flexion, extension, and lateral bending movements (each lasting 10 N·m) were performed on the superior surface of the L3 vertebra with a compressive preload of 500 N. Range of motion (ROM), peak stresses in the L4-5 cortical endplates, cage stress, and adjacent intervertebral disk stress were evaluated. Results ROMs during different physiological movements were similar to those reported by previous researchers. Compared with that in M0, L4-5 ROMs of all movements decreased in M1, M2 and M3, most evidently in M3. Stress distribution in the cortical endplates rose to 7.8% in M1 and M2, even 16.2% in M3. Cage stress increased by less than 8.1% in M1 and M2, but by 25.3% in M3, especially in the movements of extension and right rotation. Compared with that in M0, L3-4 and L5-S1 intervertebral disk stress increased with bone density in all the other models, by up to 69.8% and 98.3%, respectively. As osteoporosis worsened, stress in the adjacent intervertebral disk also increased. Conclusion Stand-alone OLIF in M3 is not recommended because of the risk of cage subsidence. OLIF in M1 and M2 achieved similar results in various lumbar spine movements. In M1 and M2 model (T > - 2.5), the L4-L5 showed reduced mobility in all directions, increased rigidity, limited cage displacement, lessened deformation, and better stability.
Collapse
Affiliation(s)
- Shuangtao Xue
- Darpartment of Orthopaedics, The Second People’s Hospital of Wuhu, Wuhu Hospital Affiliated to East China Normal University, Wuhu, 241001 Anhui China
| | - Tianliang Wu
- Darpartment of Orthopaedics, The Second People’s Hospital of Wuhu, Wuhu Hospital Affiliated to East China Normal University, Wuhu, 241001 Anhui China
| |
Collapse
|
32
|
Yang C, Zeng Z, Yan H, Wu J, Lv X, Zhang D, Zhang Z, Jiang X, Zhang C, Fu G, Peng X, Wang Z, Zhao Q, Li W, Huang R, Wang Q, Li B, Hu X, Wang P, Gao L. Application of vertebral body compression osteotomy in pedicle subtraction osteotomy on ankylosing spondylitis kyphosis: Finite element analysis and retrospective study. Front Endocrinol (Lausanne) 2023; 14:1131880. [PMID: 37033224 PMCID: PMC10076869 DOI: 10.3389/fendo.2023.1131880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Accepted: 02/27/2023] [Indexed: 04/11/2023] Open
Abstract
BACKGROUND Ankylosing spondylitis (AS) is a chronic inflammatory rheumatic disease, with pathological characteristics of bone erosion, inflammation of attachment point, and bone ankylosis. Due to the ossified intervertebral disc and ligament, pedicle subtraction osteotomy (PSO) is one of the mainstream surgeries of AS-related thoracolumbar kyphosis, but the large amount of blood loss and high risk of instrumental instability limit its clinical application. The purpose of our study is to propose a new transpedicular vertebral body compression osteotomy (VBCO) in PSO to reduce blood loss and improve stability. METHODS A retrospective analysis was performed on patients with AS-related thoracolumbar kyphosis who underwent one-level PSO in our hospital from February 2009 to May 2019. A total of 31 patients were included in this study; 6 received VBCO and 25 received eggshell vertebral body osteotomy. We collected demographic data containing gender and age at diagnosis. Surgical data contained operation time, estimated blood loss (EBL), and complications. Radiographic data contained pre-operative and follow-up sagittal parameters including chin brow-vertical angle (CBVA), global kyphosis (GK), thoracic kyphosis (TK), and lumbar lordosis (LL). A typical case with L2-PSO was used to establish a finite element model. The mechanical characteristics of the internal fixation device, vertebral body, and osteotomy plane of the two osteotomy models were analyzed under different working conditions. RESULTS The VBCO could provide comparable restoring of CBVA, GK, TK, and LL in the eggshell osteotomy procedure (all p > 0.05). The VBCO significantly reduced EBL compared to those with eggshell osteotomy [800.0 ml (500.0-1,439.5 ml) vs. 1,455.5 ml (1,410.5-1,497.8 ml), p = 0.033]. Compared with the eggshell osteotomy, VBCO showed better mechanical property. For the intra-pedicular screw fixation, the VBCO group had a more average distributed and lower stress condition on both nails and connecting rod. VBCO had a flattened osteotomy plane than the pitted osteotomy plane of the eggshell group, showing a lower and more average distributed maximum stress and displacement of osteotomy plane. CONCLUSION In our study, we introduced VBCO as an improved method in PSO, with advantages in reducing blood loss and providing greater stability. Further investigation should focus on clinical research and biomechanical analysis for the application of VBCO.
Collapse
Affiliation(s)
- Canchun Yang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Ziliang Zeng
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Haolin Yan
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Jionglin Wu
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Xin Lv
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Di Zhang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Zhilei Zhang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Xu Jiang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Chi Zhang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Guo Fu
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Xiaoshuai Peng
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Zheyu Wang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Qiancheng Zhao
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Wenpeng Li
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Renyuan Huang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Qiwei Wang
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
| | - Bo Li
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
- *Correspondence: Bo Li, ; ; Xumin Hu, ; Liangbin Gao, ; Peng Wang,
| | - Xumin Hu
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
- *Correspondence: Bo Li, ; ; Xumin Hu, ; Liangbin Gao, ; Peng Wang,
| | - Peng Wang
- Department of Orthopedics, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, China
- *Correspondence: Bo Li, ; ; Xumin Hu, ; Liangbin Gao, ; Peng Wang,
| | - Liangbin Gao
- Department of Orthopedics, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, China
- *Correspondence: Bo Li, ; ; Xumin Hu, ; Liangbin Gao, ; Peng Wang,
| |
Collapse
|
33
|
Wang R, Wu Z. Recent advancement in finite element analysis of spinal interbody cages: A review. Front Bioeng Biotechnol 2023; 11:1041973. [PMID: 37034256 PMCID: PMC10076720 DOI: 10.3389/fbioe.2023.1041973] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 03/13/2023] [Indexed: 04/11/2023] Open
Abstract
Finite element analysis (FEA) is a widely used tool in a variety of industries and research endeavors. With its application to spine biomechanics, FEA has contributed to a better understanding of the spine, its components, and its behavior in physiological and pathological conditions, as well as assisting in the design and application of spinal instrumentation, particularly spinal interbody cages (ICs). IC is a highly effective instrumentation for achieving spinal fusion that has been used to treat a variety of spinal disorders, including degenerative disc disease, trauma, tumor reconstruction, and scoliosis. The application of FEA lets new designs be thoroughly "tested" before a cage is even manufactured, allowing bio-mechanical responses and spinal fusion processes that cannot easily be experimented upon in vivo to be examined and "diagnosis" to be performed, which is an important addition to clinical and in vitro experimental studies. This paper reviews the recent progress of FEA in spinal ICs over the last six years. It demonstrates how modeling can aid in evaluating the biomechanical response of cage materials, cage design, and fixation devices, understanding bone formation mechanisms, comparing the benefits of various fusion techniques, and investigating the impact of pathological structures. It also summarizes the various limitations brought about by modeling simplification and looks forward to the significant advancement of spine FEA research as computing efficiency and software capabilities increase. In conclusion, in such a fast-paced field, the FEA is critical for spinal IC studies. It helps in quantitatively and visually demonstrating the cage characteristics after implanting, lowering surgeons' learning costs for new cage products, and probably assisting them in determining the best IC for patients.
Collapse
Affiliation(s)
- Ruofan Wang
- Guangzhou Key Laboratory of Spine Disease Prevention and Treatment, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Orthopaedic Surgery, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Zenghui Wu
- Guangzhou Key Laboratory of Spine Disease Prevention and Treatment, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Orthopaedic Surgery, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- *Correspondence: Zenghui Wu,
| |
Collapse
|
34
|
Wu J, Han Y, Xu H, Yang D, Wen W, Xu H, Miao J. Biomechanical comparison of spinal column shortening - a finite element study. BMC Musculoskelet Disord 2022; 23:1122. [PMID: 36550443 PMCID: PMC9783724 DOI: 10.1186/s12891-022-06047-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 12/01/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND At present, research on spinal shortening is mainly focused on the safe distance of spinal shortening and the mechanism of spinal cord injury, but there is no research on the biomechanical characteristics of different shortening distances. The purpose of this study was to study the biomechanical characteristics of spine and internal fixation instruments at different shortening distances by the finite element (FE) method. METHODS An FE model of lumbar L1-S was established and referred to the previous in vitro experiments to verify the rationality of the model by verifying the Intradiscal pressure (IDP) and the range of motion (ROM) of the motion segment. Five element models of spinal shortening were designed under the safe distance of spinal shortening, and the entire L3 vertebra and both the upper and lower intervertebral discs were resected. Model A was not shortened, while models B-E were shortened by 10%, 20%, 30% and 50% of the vertebral body, respectively. Constraining the ROM of the sacrum in all directions, a 7.5 N ·m moment and 280 N follower load were applied on the L1 vertebra to simulate the motion of the lumbar vertebrae in three planes. The ROM of the operated segments, the Von Mises stress (VMS) of the screw-rod system, the VMS of the upper endplate at the interface between the titanium cage and the L4 vertebral body, and the ROM and the IDP of the adjacent segment (L5/S) were recorded and analysed. RESULTS All surgical models showed good stability at the operated segments (L1-5), with the greatest constraint in posterior extension (99.3-99.7%), followed by left-right bending (97.9-98.7%), and the least constraint in left-right rotation (84.9-86.3%) compared with the intact model. The VMS of the screw-rod system and the ROM and IDP of the distal adjacent segments of models A-E showed an increasing trend, in which the VMS of the screw-rod system of model E was the highest under flexion (172.5 MPa). The VMS of the endplate at the interface between the cage and L4 upper endplate of models A-E decreased gradually, and these trend were the most obvious in flexion, which were 3.03, 2.95, 2.83, 2.78, and 2.61 times that of the intact model, respectively. CONCLUSION When performing total vertebrae resection and correcting the spinal deformity, if the corrected spine has met our needs, the distance of spinal shortening should be minimized to prevent spinal cord injury, fracture of internal fixations and adjacent segment disease (ASD).
Collapse
Affiliation(s)
- Jincheng Wu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| | - Ye Han
- grid.459324.dThe Affiliated Hospital of Hebei University, Baoding City, Hebei China
| | - Hanpeng Xu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| | - Dongmei Yang
- grid.284723.80000 0000 8877 7471Southern Medical University, Guangzhou City, China
| | - Wangqiang Wen
- grid.443397.e0000 0004 0368 7493The First Affiliated Hospital of Hainan Medical University, Haikou City, Hainan, China
| | - Haoxiang Xu
- The Second People’s Hospital of Hefei, Hefei, Anhui, China
| | - Jun Miao
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, China
| |
Collapse
|
35
|
Stepwise reduction of bone mineral density increases the risk of cage subsidence in oblique lumbar interbody fusion patients biomechanically: an in-silico study. BMC Musculoskelet Disord 2022; 23:1083. [PMID: 36503614 PMCID: PMC9743582 DOI: 10.1186/s12891-022-06049-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 12/01/2022] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Cage subsidence causes poor prognoses in patients treated by oblique lumbar interbody fusion (OLIF). Deterioration of the biomechanical environment initially triggers cage subsidence, and patients with low bone mineral density (BMD) suffer a higher risk of cage subsidence. However, whether low BMD increases the risk of cage subsidence by deteriorating the local biomechanical environment has not been clearly identified. METHODS OLIF without additional fixation (stand-alone, S-A) and with different additional fixation devices (AFDs), including anterolateral single rod screws (ALSRs) and bilateral pedicle screws (BPSs) fixation, was simulated in the L4-L5 segment of a well-validated finite element model. The biomechanical effects of different BMDs were investigated by adjusting the material properties of bony structures. Biomechanical indicators related to cage subsidence were computed and recorded under different directional moments. RESULTS Overall, low BMD triggers stress concentration in surgical segment, the highest equivalent stress can be observed in osteoporosis models under most loading conditions. Compared with the flexion-extension loading condition, this variation tendency was more pronounced under bending and rotation loading conditions. In addition, AFDs obviously reduced the stress concentration on both bony endplates and the OLIF cage, and the maximum stress on ALSRs was evidently higher than that on BPSs under almost all loading conditions. CONCLUSIONS Stepwise reduction of BMD increases the risk of a poor local biomechanical environment in OLIF patients, and regular anti-osteoporosis therapy should be considered an effective method to biomechanically optimize the prognosis of OLIF patients.
Collapse
|
36
|
Nan C, Ma Z, Liu Y, Ma L, Li J, Zhang W. Impact of cage position on biomechanical performance of stand-alone lateral lumbar interbody fusion: a finite element analysis. BMC Musculoskelet Disord 2022; 23:920. [PMID: 36258213 PMCID: PMC9578219 DOI: 10.1186/s12891-022-05873-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 10/04/2022] [Indexed: 11/24/2022] Open
Abstract
Background This study aimed to compare the biomechanical performance of various cage positions in stand-alone lateral lumbar interbody fusion(SA LLIF). Methods An intact finite element model of the L3-L5 was reconstructed. The model was verified and analyzed. Through changing the position of the cage, SA LLIF was established in four directions: anterior placement(AP), middle placement(MP), posterior placement(PP), oblique placement(OP). A 400 N vertical axial pre-load was imposed on the superior surface of L3 and a 10 N/m moment was applied on the L3 superior surface along the radial direction to simulate movements of flexion, extension, lateral bending, and axial rotation. Various biomechanical parameters were evaluated for intact and implanted models in all loading conditions, including the range of motion (ROM) and maximum stress. Results In the SA LLIF models, the ROM of L4-5 was reduced by 84.21–89.03% in flexion, 72.64–82.26% in extension, 92.5-95.85% in right and left lateral bending, and 87.22–92.77% in right and left axial rotation, respectively. Meanwhile, ROM of L3-4 was mildly increased by an average of 9.6% in all motion directions. Almost all stress peaks were increased after SA LLIF, including adjacent disc, facet joints, and endplates. MP had lower stress peaks of cage and endplates in most motion modes. In terms of the stress on facet joints and disc of the cephalad segment, MP had the smallest increment. Conclusion In our study, SA LLIF risked accelerating the adjacent segment degeneration. The cage position had an influence on the distribution of endplate stress and the magnitude of facet joint stress. Compared with other positions, MP had the slightest effect on the stress in the adjacent facet joints. Meanwhile, MP seems to play an important role in reducing the risk of cage subsidence.
Collapse
Affiliation(s)
- Chong Nan
- Department of Spinal Surgery, The Third Hospital of Hebei Medical University, 050000, Shijiazhuang, Hebei Province, China
| | - Zhanbei Ma
- Department of Orthopedic, Central Hospital, Baoding No. 1, 071000, Baoding, Hebei Province, China
| | - Yuxiu Liu
- Department of Orthopedic, Central Hospital, Baoding No. 1, 071000, Baoding, Hebei Province, China
| | - Liang Ma
- Department of Orthopedic, Central Hospital, Baoding No. 1, 071000, Baoding, Hebei Province, China
| | - Jiaqi Li
- Department of Spinal Surgery, The Third Hospital of Hebei Medical University, 050000, Shijiazhuang, Hebei Province, China
| | - Wei Zhang
- Department of Spinal Surgery, The Third Hospital of Hebei Medical University, 050000, Shijiazhuang, Hebei Province, China.
| |
Collapse
|
37
|
Lin GX, Chen CM, Jhang SW, Zhu MT, Lyu P, Hu BS. Characteristics and hotspots of the 50 most cited articles in the field of pre-psoas oblique lumbar interbody fusion. Front Surg 2022; 9:1004839. [PMID: 36311953 PMCID: PMC9597085 DOI: 10.3389/fsurg.2022.1004839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 09/23/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE In the past decade, the field of pre-psoas oblique lumbar interbody fusion (OLIF) has developed rapidly, and with it, the literature on OLIF has grown considerably. This study was designed to analyze the top 50 articles in terms of the number of citations through bibliometric research to demonstrate the research characteristics and hotspots of OLIF. METHOD Searching the Web of Science database yielded the 50 most cited publications in the OLIF field as of July 10, 2022. The publications were ranked according to the number of citations. The following sources were evaluated: the year of publications, the number of citations, authors, countries, institutions, journals, research topics, and keyword hotspots. RESULTS The most productive period was from 2017 to 2020, with 41 articles. The number of citations varied from 10 to 140, with an average of 35.52, and 1,776 citations were found. World Neurosurgery published the most articles (12), China produced the most articles (16), and the Catholic University of Korea produced the most studies (6). The corresponding author who produced the most articles was J.S. Kim (5), and the first author who produced the most publications was S. Orita (3). The main research topics were anatomical morphology, surgical techniques, indications, outcomes, and complications. The top 10 most cited keywords were "complications," "decompression," "spine," "surgery," "outcomes," "transpsoas approach," "spondylolisthesis," "anterior," "disease," and "injury." CONCLUSIONS Certain articles can be distinguished from others using citation analysis as an accurate representation of their impact due to their long-term effectiveness and peer recognition. With these publications, researchers are provided with research priorities and hotspots through influential literature in the field of OLIF.
Collapse
Affiliation(s)
- Guang-Xun Lin
- The School of Clinical Medicine, The Third Clinical Medical College, Fujian Medical University, China,Department of Orthopedics, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Chien-Min Chen
- Division of Neurosurgery, Department of Surgery, Changhua Christian Hospital, Changhua, Taiwan,Department of Leisure Industry Management, National Chin-Yi University of Technology, Taichung, Taiwan,College of Nursing and Health Sciences, Dayeh University, Taiwan
| | - Shang-Wun Jhang
- Division of Neurosurgery, Department of Surgery, Changhua Christian Hospital, Changhua, Taiwan
| | - Ming-Tao Zhu
- Department of Neurosurgery, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Correspondence: Bao-Shan Hu Ming-Tao Zhu Pengfei Lyu
| | - Pengfei Lyu
- Department of Breast Surgery, The First Affiliated Hospital of Hainan Medical University, Haikou, China,Correspondence: Bao-Shan Hu Ming-Tao Zhu Pengfei Lyu
| | - Bao-Shan Hu
- Department of Orthopedics, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China,Correspondence: Bao-Shan Hu Ming-Tao Zhu Pengfei Lyu
| |
Collapse
|
38
|
Wu J, Yang D, Han Y, Xu H, Wen W, Xu H, Li K, Liu Y, Miao J. Application of dual-trajectory screws in revision surgery for lumbar adjacent segment disease: a finite element study. J Orthop Surg Res 2022; 17:427. [PMID: 36153558 PMCID: PMC9509616 DOI: 10.1186/s13018-022-03317-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 09/07/2022] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Advancements in medicine and the popularity of lumbar fusion surgery have made lumbar adjacent segment disease (ASDz) increasingly common, but there is no mature plan for guiding its surgical treatment. Therefore, in this study, four different finite element (FE) ASDz models were designed and their biomechanical characteristics were analysed to provide a theoretical basis for clinical workers to choose the most appropriate revision scheme for ASDz. METHODS According to whether internal fixation was retained, different FE models were created to simulate ASDz revision surgery, and flexion, extension, axial rotation and lateral bending were simulated by loading. The biomechanical characteristics of the adjacent segments of the intervertebral disc and the internal fixation system and the range of motion (ROM) of the lumbar vertebrae were analysed. RESULTS The difference in the ROM of the fixed segment between FE models that did or did not retain the original internal fixation was less than 0.1°, and the difference was not significant. However, the stress of the screw-rod system when the original internal fixation was retained and prolonged fixation was performed with dual-trajectory screws was less than that when the original internal fixation was removed and prolonged fixation was performed with a long bar. Especially in axial rotation, the difference between models A and B is the largest, and the difference in peak stress reached 30 MPa. However, for the ASDz revision surgery segment, the endplate stress between the two models was the lowest, and the intradiscal pressure (IDP) of the adjacent segment was not significantly different between different models. CONCLUSION Although ASDz revision surgery by retaining the original internal fixation and prolonging fixation with dual-trajectory screws led to an increase in stress in the fusion segment endplate, it provides stability similar to ASDz revision surgery by removing the original internal fixation and prolonging fixation with a long bar and does not lead to a significant change in the IDP of the adjacent segment while avoiding a greater risk of rod fracture.
Collapse
Affiliation(s)
- Jincheng Wu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, 300210 China
| | - Dongmei Yang
- grid.284723.80000 0000 8877 7471Southern Medical University, Guangzhou City, Guangdong China
| | - Ye Han
- grid.459324.dThe Affiliated Hospital of Hebei University, Baoding City, Hebei China
| | - Hanpeng Xu
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, 300210 China
| | - Wangqiang Wen
- The First Affiliated Hospital of Hainan Medical University, Haikou City, Hainan China
| | - Haoxiang Xu
- The Second People’s Hospital of Hefei, Hefei, Anhui China
| | - Kepeng Li
- Second Central Hospital of Baoding, Zhuozhou City, Hebei China
| | - Yong Liu
- Pingyao County Traditional Chinese Medicine Hospital, Jinzhong City, Shanxi China
| | - Jun Miao
- grid.33763.320000 0004 1761 2484Department of Spine Surgery, Tianjin Hospital, Tianjin University, Jiefangnanlu 406, Hexi District, Tianjin, 300210 China
| |
Collapse
|
39
|
Huang CY, Zhang ZF, Zhang XY, Liu F, Fang ZX, Xi ZP, Li JC. Poor bone mineral density aggravates adjacent segment's motility compensation in patients with oblique lumbar interbody fusion with and without pedicle screw fixation: An in silico study. Front Surg 2022; 9:967399. [PMID: 36117812 PMCID: PMC9470755 DOI: 10.3389/fsurg.2022.967399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 08/15/2022] [Indexed: 11/24/2022] Open
Abstract
Objective Motility compensation increases the risk of adjacent segment diseases (ASDs). Previous studies have demonstrated that patients with ASD have a poor bone mineral density (BMD), and changes in BMD affect the biomechanical environment of bones and tissues, possibly leading to an increase in ASD incidence. However, whether poor BMD increases the risk of ASD by aggravating the motility compensation of the adjacent segment remains unclear. The present study aimed to clarify this relationship in oblique lumbar interbody fusion (OLIF) models with different BMDs and additional fixation methods. Methods Stand-alone (S-A) OLIF and OLIF fixed with bilateral pedicle screws (BPS) were simulated in the L4–L5 segment of our well-validated lumbosacral model. Range of motions (ROMs) and stiffness in the surgical segment and at the cranial and caudal sides’ adjacent segments were computed under flexion, extension, and unilateral bending and axial rotation loading conditions. Results Under most loading conditions, the motility compensation of both cranial and caudal segments adjacent to the OLIF segment steeply aggravated with BMD reduction in S-A and BPS OLIF models. More severe motility compensation of the adjacent segment was observed in BPS models than in S-A models. Correspondingly, the surgical segment's stiffness of S-A models was apparently lower than that of BPS models (S-A models showed higher ROMs and lower stiffness in the surgical segment). Conclusion Poor BMD aggravates the motility compensation of adjacent segments after both S-A OLIF and OLIF with BPS fixation. This variation may cause a higher risk of ASD in OLIF patients with poor BMD. S-A OLIF cannot provide instant postoperative stability; therefore, the daily motions of patients with S-A OLIF should be restricted before ideal interbody fusion to avoid surgical segment complications.
Collapse
Affiliation(s)
- Chen-Yi Huang
- Department of Orthopedics, Hospital (T.C.M) Affiliated to Southwest Medical University, Luzhou, China
| | - Zi-Fan Zhang
- Department of Spine Surgery, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
| | - Xiao-Yu Zhang
- Department of Orthopedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine for Nanjing University of Chinese Medicine, Nanjing, China
| | - Fei Liu
- Department of Orthopedics, Hospital (T.C.M) Affiliated to Southwest Medical University, Luzhou, China
| | - Zhong-Xin Fang
- Fluid and Power Machinery Key Laboratory of Ministry of Education, Xihua University, Chengdu, China
| | - Zhi-Peng Xi
- Department of Orthopedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine for Nanjing University of Chinese Medicine, Nanjing, China
- Correspondence: Jing-Chi Li Zhi-Peng Xi
| | - Jing-Chi Li
- Department of Orthopedics, Hospital (T.C.M) Affiliated to Southwest Medical University, Luzhou, China
- Department of Orthopedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine for Nanjing University of Chinese Medicine, Nanjing, China
- Correspondence: Jing-Chi Li Zhi-Peng Xi
| |
Collapse
|
40
|
Li JC, Yang ZQ, Xie TH, Song ZT, Song YM, Zeng JC. Deterioration of the fixation segment’s stress distribution and the strength reduction of screw holding position together cause screw loosening in ALSR fixed OLIF patients with poor BMD. Front Bioeng Biotechnol 2022; 10:922848. [PMID: 36110315 PMCID: PMC9468878 DOI: 10.3389/fbioe.2022.922848] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 07/29/2022] [Indexed: 11/16/2022] Open
Abstract
The vertebral body’s Hounsfield unit (HU) value can credibly reflect patients’ bone mineral density (BMD). Given that poor bone-screw integration initially triggers screw loosening and regional differences in BMD and strength in the vertebral body exist, HU in screw holding planes should better predict screw loosening. According to the stress shielding effect, the stress distribution changes in the fixation segment with BMD reduction should be related to screw loosening, but this has not been identified. We retrospectively collected the radiographic and demographic data of 56 patients treated by single-level oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) screw fixation. BMD was identified by measuring HU values in vertebral bodies and screw holding planes. Regression analyses identified independent risk factors for cranial and caudal screw loosening separately. Meanwhile, OLIF with ALSR fixation was numerically simulated; the elastic modulus of bony structures was adjusted to simulate different grades of BMD reduction. Stress distribution changes were judged by computing stress distribution in screws, bone-screw interfaces, and cancellous bones in the fixation segment. The results showed that HU reduction in vertebral bodies and screw holding planes were independent risk factors for screw loosening. The predictive performance of screw holding plane HU is better than the mean HU of vertebral bodies. Cranial screws suffer a higher risk of screw loosening, but HU was not significantly different between cranial and caudal sides. The poor BMD led to stress concentrations on both the screw and bone-screw interfaces. Biomechanical deterioration was more severe in the cranial screws than in the caudal screws. Additionally, lower stress can also be observed in fixation segments’ cancellous bone. Therefore, a higher proportion of ALSR load transmission triggers stress concentration on the screw and bone-screw interfaces in patients with poor BMD. This, together with decreased bony strength in the screw holding position, contributes to screw loosening in osteoporotic patients biomechanically. The trajectory optimization of ALSR screws based on preoperative HU measurement and regular anti-osteoporosis therapy may effectively reduce the risk of screw loosening.
Collapse
Affiliation(s)
- Jing-Chi Li
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Zhi-Qiang Yang
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Tian-Hang Xie
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Zhe-Tao Song
- Department of Imaging, West China Hospital, Chengdu, China
| | - Yue-Ming Song
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
- *Correspondence: Yue-Ming Song, ; Jian-Cheng Zeng,
| | - Jian-Cheng Zeng
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
- *Correspondence: Yue-Ming Song, ; Jian-Cheng Zeng,
| |
Collapse
|
41
|
Liu ZX, Gao ZW, Chen C, Liu ZY, Cai XY, Ren YN, Sun X, Ma XL, Du CF, Yang Q. Effects of osteoporosis on the biomechanics of various supplemental fixations co-applied with oblique lumbar interbody fusion (OLIF): a finite element analysis. BMC Musculoskelet Disord 2022; 23:794. [PMID: 35986271 PMCID: PMC9392247 DOI: 10.1186/s12891-022-05645-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 07/12/2022] [Indexed: 11/25/2022] Open
Abstract
Background Oblique lumbar interbody fusion (OLIF) is an important surgical modality for the treatment of degenerative lumbar spine disease. Various supplemental fixations can be co-applied with OLIF, increasing OLIF stability and reducing complications. However, it is unclear whether osteoporosis affects the success of supplemental fixations; therefore, this study analyzed the effects of osteoporosis on various supplemental fixations co-applied with OLIF. Methods We developed and validated an L3-S1 finite element (FE) model; we assigned different material properties to each component and established models of the osteoporotic and normal bone lumbar spine. We explored the outcomes of OLIF combined with each of five supplemental fixations: standalone OLIF; OLIF with lateral plate fixation (OLIF + LPF); OLIF with translaminar facet joint fixation and unilateral pedicle screw fixation (OLIF + TFJF + UPSF); OLIF with unilateral pedicle screw fixation (OLIF + UPSF); and OLIF with bilateral pedicle screw fixation (OLIF + BPSF). Under the various working conditions, we calculated the ranges of motion (ROMs) of the normal bone and osteoporosis models, the maximum Mises stresses of the fixation instruments (MMSFIs), and the average Mises stresses on cancellous bone (AMSCBs). Results Compared with the normal bone OLIF model, no demonstrable change in any segmental ROM was apparent. The MMSFIs increased in all five osteoporotic OLIF models. In the OLIF + TFJF + UPSF model, the MMSFIs increased sharply in forward flexion and extension. The stress changes of the OLIF + UPSF, OLIF + BPSF, and OLIF + TFJF + UPSF models were similar; all stresses trended upward. The AMSCBs decreased in all five osteoporotic OLIF models during flexion, extension, lateral bending, and axial rotation. The average stress change of cancellous bone was most obvious under extension. The AMSCBs of the five OLIF models decreased by 14%, 23.44%, 21.97%, 40.56%, and 22.44% respectively. Conclusions For some supplemental fixations, the AMSCBs were all reduced and the MMSFIs were all increased in the osteoporotic model, compared with the OLIF model of normal bone. Therefore, the biomechanical performance of an osteoporotic model may be inferior to the biomechanical performance of a normal model for the same fixation method; in some instances, it may increase the risks of fracture and internal fixation failure.
Collapse
|
42
|
Huang S, Min S, Wang S, Jin A. Biomechanical effects of an oblique lumbar interbody fusion combined with posterior augmentation: a finite element analysis. BMC Musculoskelet Disord 2022; 23:611. [PMID: 35761228 PMCID: PMC9235194 DOI: 10.1186/s12891-022-05553-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Accepted: 06/06/2022] [Indexed: 11/18/2022] Open
Abstract
Background Oblique lateral interbody fusion (OLIF) is widely used to treat lumbar degenerative disc disease. This study aimed to evaluate the biomechanical stability of OLIF, OLIF including posterior pedicle screw and rod (PSR), and OLIF including cortical screw and rod (CSR) instrumentation through finite element analysis. Methods A complete L2-L5 finite element model of the lumbar spine was constructed. Surgical models of OLIF, such as stand-alone, OLIF combined with PSR, and OLIF combined with CSR were created in the L3-L4 surgical segments. Range of motion (ROM), end plate stress, and internal fixation peak stress were compared between different models under the same loading conditions. Results Compared to the intact model, ROM was reduced in the OLIF model under all loading conditions. The surgical models in order of increasing ROM were PSR, CSR, and stand-alone; however, the difference in ROM between BPS and CSR was less than 0.4° and was not significant under any loading conditions. The stand-alone model had the highest stress on the superior L4 vertebral body endplate under all loading conditions, whereas the end plate stress was relatively low in the BPS and CSR models. The CSR model had the highest internal fixation stress, concentrated primarily at the end of the screw. Conclusions OLIF alone significantly reduces ROM but does not provide sufficient stability. Addition of posterior PSR or CSR internal fixation instrumentation to OLIF surgery can significantly improve biomechanical stability of the segment undergoing surgery.
Collapse
|
43
|
Lu X, Li D, Wang H, Xia X, Ma X, Lv F, Zou F, Jiang J. Biomechanical effects of interbody cage height on adjacent segments in patients with lumbar degeneration: a 3D finite element study. J Orthop Surg Res 2022; 17:325. [PMID: 35729647 PMCID: PMC9210615 DOI: 10.1186/s13018-022-03220-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 06/07/2022] [Indexed: 11/24/2022] Open
Abstract
Objective To investigate the biomechanical effects of interbody cage height on adjacent segments in patients with lumbar degeneration undergoing transforaminal lumbar interbody fusion (TLIF) surgery, so as to provide references for selection of interbody cage. Methods The finite element model of normal lower lumbar spine (L3–S1) was built and validated, then constructed three different degenerative segments in L3–L4, and the cages with different height (8, 10, 12, 14 mm) were implanted into L4–L5 disc. All the twelve models were loaded with pure moment of 7.5 N m to produce flexion, extension, lateral bending and axial rotation motions on lumbar spine, and the effects of cage height on range of motion (RoM) and intervertebral pressure in lumbar spine were investigated. Results The RoM of adjacent segments and the maximum stress of intervertebral discs increased with the increase in cage height, but this trend was not obvious in mild and moderate degeneration groups. After implantation of four different height cages (8, 10, 12, 14 mm), the RoM of L3/L4 segment reached the maximum during extension. The RoM of mild degeneration group was 2.07°, 2.45°, 2.48°, 2.54°, that of moderate degeneration group was 1.79°, 1.97°, 2.05°, 2.05°, and that of severe degeneration group was 1.43°, 1.66°, 1.74°, 1.74°. The stress of L3–L4 intervertebral disc reached the maximum during flexion. The maximum stress of L3–L4 intervertebral disc was 20.16 MPa, 20.28 MPa, 20.31 MPa and 20.33 MPa in the mild group, 20.58 MPa, 20.66 MPa, 20.71 MPa and 20.75 MPa in the moderate group, and 21.27 MPa, 21.40 MPa, 21.50 MPa and 21.60 MPa in the severe group. Conclusion For patients with mild-to-moderate lumbar degenerative disease who need to undergo TLIF surgery, it is recommended that the height of fusion cage should not exceed the original intervertebral space height by 2 mm, while for patients with severe degeneration, a fusion cage close to the original intervertebral height should be selected as far as possible, and the intervertebral space should not be overstretched.
Collapse
Affiliation(s)
- Xiao Lu
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Dachuan Li
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Hongli Wang
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Xinlei Xia
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Xiaosheng Ma
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Feizhou Lv
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China
| | - Fei Zou
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China.
| | - Jianyuan Jiang
- Department of Orthopedics, Huashan Hospital, Fudan University, No. 12, Middle Wulumuqi Road, Jing'an District, Shanghai, 200040, China.
| |
Collapse
|
44
|
Liang W, Han B, Hai Y, Yang J, Yin P. Biomechanical Analysis of the Reasonable Cervical Range of Motion to Prevent Non-Fusion Segmental Degeneration After Single-Level ACDF. Front Bioeng Biotechnol 2022; 10:918032. [PMID: 35782514 PMCID: PMC9243332 DOI: 10.3389/fbioe.2022.918032] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 05/05/2022] [Indexed: 11/13/2022] Open
Abstract
The compensatory increase in intervertebral range of motion (ROM) after cervical fusion can increase facet joint force (FJF) and intradiscal pressure (IDP) in non-fusion segments. Guiding the post-ACDF patient cervical exercise within a specific ROM (defined as reasonable ROM) to offset the increase in FJF and IDP may help prevent segmental degeneration. This study aimed to determine the reasonable total C0–C7 ROM without an increase in FJF and IDP in non-fusion segments after anterior cervical discectomy and fusion (ACDF). A three-dimensional intact finite element model of C0–C7 generated healthy cervical conditions. This was modified to the ACDF model by simulating the actual surgery at C5–C6. A 1.0 Nm moment and 73.6 N follower load were applied to the intact model to determine the ROMs. A displacement load was applied to the ACDF model under the same follower load, resulting in a total C0–C7 ROM similar to that of the intact model. The reasonable ROMs in the ACDF model were calculated using the fitting function. The results indicated that the intervertebral ROM of all non-fusion levels was increased in the ACDF model in all motion directions. The compensatory increase in ROM in adjacent segments (C4/5 and C6/7) was more significant than that in non-adjacent segments, except for C3/4 during lateral bending. The intervertebral FJF and IDP of C0–C7 increased with increasing ROM. The reasonable ROMs in the ACDF model were 42.4°, 52.6°, 28.4°, and 42.25° in flexion, extension, lateral bending, and axial rotation, respectively, with a decreased ROM of 4.4–7.2%. The postoperative increase in FJF and IDP in non-fusion segments can be canceled out by reducing the intervertebral ROM within reasonable ROMs. This study provided a new method to estimate the reasonable ROMs after ACDF from a biomechanical perspective, and further in vitro and clinical studies are needed to confirm this.
Collapse
Affiliation(s)
| | | | - Yong Hai
- *Correspondence: Yong Hai, ; Peng Yin,
| | | | - Peng Yin
- *Correspondence: Yong Hai, ; Peng Yin,
| |
Collapse
|
45
|
Abbasi-Ghiri A, Ebrahimkhani M, Arjmand N. Novel force-displacement control passive finite element models of the spine to simulate intact and pathological conditions; comparisons with traditional passive and detailed musculoskeletal models. J Biomech 2022; 141:111173. [PMID: 35705381 DOI: 10.1016/j.jbiomech.2022.111173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 05/08/2022] [Accepted: 06/01/2022] [Indexed: 10/18/2022]
Abstract
Passive finite element (FE) models of the spine are commonly used to simulate intact and various pre- and postoperative pathological conditions. Being devoid of muscles, these traditional models are driven by simplistic loading scenarios, e.g., a constant moment and compressive follower load (FL) that do not properly mimic the complex in vivo loading condition under muscle exertions. We aim to develop novel passive FE models that are driven by more realistic yet simple loading scenarios, i.e., in vivo vertebral rotations and pathological-condition dependent FLs (estimated based on detailed musculoskeletal finite element (MS-FE) models). In these novel force-displacement control FE models, unlike the traditional passive FE models, FLs vary not only at different spine segments (T12-S1) but between intact, pre- and postoperative conditions. Intact, preoperative degenerated, and postoperative fused conditions at the L4-L5 segment for five static in vivo activities in upright and flexed postures were simulated by the traditional passive FE, novel force-displacement control FE, and gold-standard detailed MS-FE spine models. Our findings indicate that, when compared to the MS-FE models, the force-displacement control passive FE models could accurately predict the magnitude of disc compression force, intradiscal pressure, annulus maximal von Mises stress, and vector sum of all ligament forces at adjacent segments (L3-L4 and L5-S1) but failed to predict disc shear and facet joint forces. In this regard, the force-displacement control passive FE models were much more accurate than the traditional passive FE models. Clinical recommendations made based on traditional passive FE models should, therefore, be interpreted with caution.
Collapse
Affiliation(s)
- A Abbasi-Ghiri
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - M Ebrahimkhani
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - N Arjmand
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
| |
Collapse
|
46
|
Oikawa R, Murakami H, Endo H, Yan H, Yamabe D, Chiba Y, Oikawa R, Nishida N, Chen X, Sakai T, Doita M. Comparison of the susceptibility to implant failure in the lateral, posterior, and transforaminal lumbar interbody fusion: A finite element analysis. World Neurosurg 2022; 164:e835-e843. [PMID: 35605942 DOI: 10.1016/j.wneu.2022.05.056] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/13/2022] [Indexed: 11/19/2022]
Abstract
OBJECTIVE There are several techniques for lumbar interbody fusion, and implant failure following lumbar interbody fusion can be troublesome. This study aimed to compare the stress in posterior implant and peri-screw vertebral bodies among lateral lumbar interbody fusion (LLIF), posterior lumbar interbody fusion (PLIF), and transforaminal lumbar interbody fusion (TLIF) and to select the technique that is least likely to cause implant failure. METHODS We created an intact L3-L5 model and simulated the LLIF, PLIF, and TLIF techniques at L4-L5 using finite element methods. All models at the lower portion of L5 were fixed and imposed a preload of 400 N and a moment of 7.5 Nm on the upper portion of L3 to simulate flexion, extension, lateral bending, and axial rotation. We investigated the peak stresses and stress concentration in the posterior implant and peri-screw vertebral bodies for the LLIF, PLIF, and TLIF techniques. RESULTS The extension, flexion, bending, and rotation peak stresses and stress concentration in the posterior implant, and the peri-screw vertebral bodies, were the lowest in LLIF, followed by PLIF and TLIF, respectively. CONCLUSIONS It was found that implant failure was least likely to occur in LLIF, followed by PLIF and TLIF, respectively. Hence, surgeons should be aware of these factors when selecting an appropriate surgical technique and be careful for implant failure during postoperative follow-up.
Collapse
Affiliation(s)
- Ryo Oikawa
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Hideki Murakami
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan.
| | - Hirooki Endo
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Hirotaka Yan
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Daisuke Yamabe
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Yusuke Chiba
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Ryosuke Oikawa
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| | - Norihiro Nishida
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi Prefecture, Japan
| | - Xian Chen
- Faculty of Engineering, Yamaguchi University, Ube City, Yamaguchi Prefecture, Japan
| | - Takashi Sakai
- Department of Orthopedic Surgery, Yamaguchi University Graduate School of Medicine, Ube City, Yamaguchi Prefecture, Japan
| | - Minoru Doita
- Department of Orthopedic Surgery, Iwate Medical University, Yahaba Town, Iwate Prefecture, Japan
| |
Collapse
|
47
|
Bokov A, Kalinina S, Leontev A, Mlyavykh S. Circumferential Fusion Employing Transforaminal vs. Direct Lateral Lumbar Interbody Fusion—A Potential Impact on Implants Stability. Front Surg 2022; 9:827999. [PMID: 35651676 PMCID: PMC9150499 DOI: 10.3389/fsurg.2022.827999] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 03/30/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundDifferent fusion techniques were introduced in clinical practice in patients with lumbar degenerative disc disease, however, no evidence has been provided on the advantages of one technique over another.The Objective of This StudyIs to assess the potential impact of circumferential fusion employing transforaminal lumbar interbody fusion (TLIF) vs. direct lateral interbody fusion (DLIF) on pedicle screw stability.Materials and MethodsThis is a single-center prospective evaluation of consecutive 138 patients with degenerative instability of lumbar spinal segments. Either conventional transforaminal lumbar interbody fusion (TLIF) with posterior fusion or direct lateral interbody fusion (DLIF) using cages of standard dimensions, were applied. The conventional open technique was used to supplement TLIF with pedicle screws while percutaneous screw placement was used in patients treated with DLIF. The duration of the follow-up accounted for 24 months. Signs of pedicle screws loosening (PSL) and bone union after fusion were assessed by the results of CT imaging. Fisher‘s exact test was used to assess the differences in the rate of CT loosening and revision surgery because of implant instability. Logistic regression was used to assess the association between potential factors and complication rate.ResultsThe rate of PSL detected by CT and relevant revision surgery in groups treated with TLIF and DLIF accounted for 25 (32.9%) vs. 2 (3.2%), respectively, for the former and 9 (12.0%) vs. 0 (0%) for the latter (p < 0.0001 and p = 0.0043) respectively. According to the results of logistic regression, a decrease in radiodensity values and a greater number of levels fused were associated with a rise in PSL rate. DLIF application in patients with radiodensity below 140 HU was associated with a considerable decrease in complication rate. Unipolar or bipolar pseudoarthrosis in patients operated on with TLIF was associated with a rise in PSL rate while patients treated with DLIF tolerate delayed interbody fusion formation. In patients treated with TLIF supplementary total or partial posterior fusion resulted in a decline in PSL rate.ConclusionEven though the supplementary posterior fusion may considerably reduce the rate of PSL in patients treated with TLIF, the application of DLIF provide greater stability resulting in a substantial decline in PSL rate and relevant revision surgery.
Collapse
Affiliation(s)
- Andrey Bokov
- Department of Oncology and Neurosurgery, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Svetlana Kalinina
- Department of Traumatology, Orthopedics and Neurosurgery, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Andrei Leontev
- Department of Oncology and Neurosurgery, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
| | - Sergey Mlyavykh
- Department of Traumatology, Orthopedics and Neurosurgery, Privolzhsky Research Medical University, Nizhny Novgorod, Russia
- *Correspondence: Sergey Mlyavykh
| |
Collapse
|
48
|
Cai XY, Bian HM, Chen C, Ma XL, Yang Q. Biomechanical study of oblique lumbar interbody fusion (OLIF) augmented with different types of instrumentation: a finite element analysis. J Orthop Surg Res 2022; 17:269. [PMID: 35568923 PMCID: PMC9107272 DOI: 10.1186/s13018-022-03143-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 04/26/2022] [Indexed: 02/06/2023] Open
Abstract
Background To explore the biomechanical differences in oblique lumbar interbody fusion (OLIF) augmented by different types of instrumentation. Methods A three-dimensional nonlinear finite element (FE) model of an intact L3-S1 lumbar spine was built and validated. The intact model was modified to develop five OLIF surgery models (Stand-alone OLIF; OLIF with lateral plate fixation [OLIF + LPF]; OLIF with unilateral pedicle screws fixation [OLIF + UPSF]; OLIF with bilateral pedicle screws fixation [OLIF + BPSF]; OLIF with translaminar facet joint fixation + unilateral pedicle screws fixation [OLIF + TFJF + UPSF]) in which the surgical segment was L4–L5. Under a follower load of 500 N, a 7.5-Nm moment was applied to all lumbar spine models to calculate the range of motion (ROM), equivalent stress peak of fixation instruments (ESPFI), equivalent stress peak of cage (ESPC), equivalent stress peak of cortical endplate (ESPCE), and equivalent stress average value of cancellous bone (ESAVCB). Results Compared with the intact model, the ROM of the L4–L5 segment in each OLIF surgery model decreased by > 80%. The ROM values of adjacent segments were not significantly different. The ESPFI, ESPC, and ESPCE values of the OLIF + BPSF model were smaller than those of the other OLIF surgery models. The ESAVCB value of the normal lumbar model was less than the ESAVCB values of all OLIF surgical models. In most postures, the ESPFI, ESPCE, and ESAVCB values of the OLIF + LPF model were the largest. The ESPC was higher in the Stand-alone OLIF model than in the other OLIF models. The stresses of several important components of the OLIF + UPSF and OLIF + TFJF + UPSF models were between those of the OLIF + LPF and OLIF + BPSF models. Conclusions Our biomechanical FE analysis indicated the greater ability of OLIF + BPSF to retain lumbar stability, resist cage subsidence, and maintain disc height. Therefore, in the augmentation of OLIF, bilateral pedicle screws fixation may be the best approach.
Collapse
Affiliation(s)
- Xin-Yi Cai
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, 406 Jiefang South Road, Hexi District, Tianjin, 300211, China.,Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, 300384, China
| | | | - Chao Chen
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, 406 Jiefang South Road, Hexi District, Tianjin, 300211, China
| | - Xin-Long Ma
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, 406 Jiefang South Road, Hexi District, Tianjin, 300211, China
| | - Qiang Yang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, 406 Jiefang South Road, Hexi District, Tianjin, 300211, China.
| |
Collapse
|
49
|
Li JC, Xie TH, Zhang Z, Song ZT, Song YM, Zeng JC. The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically. Front Bioeng Biotechnol 2022; 10:862951. [PMID: 35464717 PMCID: PMC9023805 DOI: 10.3389/fbioe.2022.862951] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 03/24/2022] [Indexed: 12/26/2022] Open
Abstract
The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechanical effects of the mismatch between BEP and GB and the related risk of screw loosening. In this study, radiographic and demographic data of 56 patients treated by single segment oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) fixation were collected retrospectively, and the match sufficiency between BEP and GB was measured and presented as the grafted bony occupancy rate (GBOR). Data in patients with and without screw loosening were compared; regression analyses identified independent risk factors. OLIF with different GBORs was simulated in a previously constructed and validated lumbosacral model, and biomechanical indicators related to screw loosening were computed in surgical models. The radiographic review and numerical simulations showed that the coronal plane’s GBOR was significantly lower in screw loosening patients both in the cranial and caudal vertebral bodies; the decrease in the coronal plane’s GBOR has been proven to be an independent risk factor for screw loosening. In addition, numerical mechanical simulations showed that the poor match between BEP and GB will lead to stress concentration on both screws and bone-screw interfaces. Therefore, we can conclude that the mismatch between the BEP and GB will increase the risk of screw loosening by deteriorating local stress levels, and the increase in the GBOR by modifying the OLIF cage’s design may be an effective method to optimize the patient’s prognosis.
Collapse
Affiliation(s)
- Jing-Chi Li
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Tian-Hang Xie
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Zhuang Zhang
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
| | - Zhe-Tao Song
- Department of Imaging, West China Hospital, Chengdu, China
| | - Yue-Ming Song
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
- *Correspondence: Yue-Ming Song, ; Jian-Cheng Zeng,
| | - Jian-Cheng Zeng
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, China
- *Correspondence: Yue-Ming Song, ; Jian-Cheng Zeng,
| |
Collapse
|
50
|
Wang Y, Wang J, Tu S, Li S, Yi J, Zhao H, Qiao H, Yan K, Liao B. Biomechanical Evaluation of an Oblique Lateral Locking Plate System for Oblique Lumbar Interbody Fusion: A Finite Element Analysis. World Neurosurg 2022; 160:e126-e141. [PMID: 35031519 DOI: 10.1016/j.wneu.2021.12.105] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 12/26/2021] [Accepted: 12/27/2021] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The oblique lateral locking plate system (OLLPS) is a novel internal fixation with a locking and reverse pedicle track screw configuration designed for oblique lumbar interbody fusion (OLIF). The OLLPS is placed in a single position through the oblique lateral surgical corridor to reduce operative time and complications associated with prolonged anesthesia and prone positioning. The purpose of this study was to verify the biomechanical effect of the OLLPS. METHODS An intact finite element model of L1-S1 (intact) was established based on computed tomography images of a healthy male volunteer. The L4-L5 intervertebral space was selected as the surgical segment. The surgical models were established separately based on OLIF surgical procedures and different internal fixations: 1) stand-alone OLIF (SA); 2) OLIF with a 2-screw lateral plate; 3) OLIF with a 4-screw lateral plate; 4) OLIF with OLLPS; and 5) OLIF with bilateral pedicle screw fixation (BPS). After validation of the intact model, physiologic loads were applied to the superior surface of L1 to simulate motions such as flexion, extension, left bending, right bending, left rotation, and right rotation. The evaluation indices included the L4/5 range of motion, the L4 maximum displacement, and the maximum stresses of the superior and inferior end plates, the cage, and the supplemental fixation. RESULTS During OLIF surgery, the OLLPS provided multiplanar stability similar to that provided by BPS. Compared with 2-screw lateral plate and 4-screw lateral plate, OLLPS had better biomechanical properties in terms of enhancing the instant stability of the surgical segment, reducing the stress on the superior and inferior end plates of the surgical segment, and decreasing the risk of cage subsidence. CONCLUSIONS With a minimally invasive background, the OLLPS can be used as an alternative to BPS in OLIF and it has better prospects for clinical promotions and applications.
Collapse
Affiliation(s)
- Yinge Wang
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China; Department of Orthopedics, The 922nd Hospital of Joint Logistics Support Force, Hengyang, Hunan, China
| | - Jiajia Wang
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
| | - Sha Tu
- Department of Nutrition, The 922nd Hospital of Joint Logistics Support Force, Hengyang, Hunan, China
| | - Shuang Li
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
| | - Jiangpu Yi
- 3D Printing Research Center, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
| | - Haien Zhao
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
| | - Huanhuan Qiao
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China
| | - Kang Yan
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China.
| | - Bo Liao
- Department of Orthopedics, The Second Affiliated Hospital of Air Force Medical University, Xi'an, Shaanxi, China.
| |
Collapse
|