1
|
Park G, Rim YA, Sohn Y, Nam Y, Ju JH. Replacing Animal Testing with Stem Cell-Organoids : Advantages and Limitations. Stem Cell Rev Rep 2024:10.1007/s12015-024-10723-5. [PMID: 38639829 DOI: 10.1007/s12015-024-10723-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/08/2024] [Indexed: 04/20/2024]
Abstract
Various groups including animal protection organizations, medical organizations, research centers, and even federal agencies such as the U.S. Food and Drug Administration, are working to minimize animal use in scientific experiments. This movement primarily stems from animal welfare and ethical concerns. However, recent advances in technology and new studies in medicine have contributed to an increase in animal experiments throughout the years. With the rapid increase in animal testing, concerns arise including ethical issues, high cost, complex procedures, and potential inaccuracies.Alternative solutions have recently been investigated to address the problems of animal testing. Some of these technologies are related to stem cell technologies, such as organ-on-a-chip, organoids, and induced pluripotent stem cell models. The aim of the review is to focus on stem cell related methodologies, such as organoids, that can serve as an alternative to animal testing and discuss its advantages and limitations, alongside regulatory considerations.Although stem cell related methodologies has shortcomings, it has potential to replace animal testing. Achieving this requires further research on stem cells, with potential societal and technological benefits.
Collapse
Affiliation(s)
- Guiyoung Park
- School of Biopharmaceutical and Medical Sciences, Health & Wellness College, Sungshin Women's University, 55, Dobong-ro 76ga-gil, Gangbuk-gu, Seoul, Republic of Korea
| | - Yeri Alice Rim
- CiSTEM laboratory, Convergent Research Consortium for Immunologic Disease, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
- Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, Institute of Medical Science, College of Medicine, The Catholic University of Korea, 4 3, Seoul, 06591, Republic of Korea
- Department of Biomedicine & Health Sciences, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Yeowon Sohn
- Department of Biohealth Regulatory Science, Sungkyunkwan University, Suwon, South Korea
| | - Yoojun Nam
- Department of Biohealth Regulatory Science, Sungkyunkwan University, Suwon, South Korea.
- Yipscell Inc, L2 Omnibus Park, Banpo-dearo 222, Seocho-gu, Seoul, Korea.
| | - Ji Hyeon Ju
- CiSTEM laboratory, Convergent Research Consortium for Immunologic Disease, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
- Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, Institute of Medical Science, College of Medicine, The Catholic University of Korea, 4 3, Seoul, 06591, Republic of Korea.
- Department of Biomedicine & Health Sciences, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
- Yipscell Inc, L2 Omnibus Park, Banpo-dearo 222, Seocho-gu, Seoul, Korea.
| |
Collapse
|
2
|
Deshmukh R, Singh R, Mishra S. Pharmaceutical In Situ Gel for Glaucoma: Recent Trends and Development with an Update on Research and Patents. Crit Rev Ther Drug Carrier Syst 2024; 41:1-44. [PMID: 38037819 DOI: 10.1615/critrevtherdrugcarriersyst.v41.i3.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
Glaucoma is a progressive visual polyneuropathy characterized by retinal ganglion cell atrophy and optic nerve head changes. It's generally triggered due to increased intraocular pressure compared with the healthy eye. Glaucoma is treated with various medications in traditional eye drops, such as prostaglandins, carbonic anhydrase inhibitors, beta-blockers, and others. Such treatments are difficult to use and produce lachrymal leakage and inadequate corneal permeability, resulting in lower availability. Ophthalmic in situ gels, introduced in past decades with tremendous effort, are among the finest various choices to solve the drawbacks of eye drops. Employing different polymers with pH-triggered, temperature-triggered, and ion-activated processes have been used to generate ophthalmic in situ gelling treatments. Once those preparations are delivered into the eye, they change phase from sol to gel, allowing the medicine to stay in the eye for longer. These formulations are known as smart gels as they turn into gelling fluids when administered into the eyes. The different mechanisms of in situ gel formulations are used for the management of glaucoma and are discussed in this review article.
Collapse
Affiliation(s)
- Rohitas Deshmukh
- Institute of Pharmaceutical Research, GLA University, Mathura 281406, India
| | - Rajesh Singh
- Institute of Pharmaceutical Research, GLA University, Mathura 281406, India
| | - Sakshi Mishra
- Institute of Pharmaceutical Research, GLA University, Mathura 281406, India
| |
Collapse
|
3
|
Development of a novel ex vivo model for chemical ocular toxicity assessment and its applicability for hair straightening products. Food Chem Toxicol 2022; 170:113457. [DOI: 10.1016/j.fct.2022.113457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 09/09/2022] [Accepted: 09/29/2022] [Indexed: 11/05/2022]
|
4
|
Preparation and Characterisation of a Cyclodextrin-Complexed Mānuka Honey Microemulsion for Eyelid Application. Pharmaceutics 2022; 14:pharmaceutics14071493. [PMID: 35890390 PMCID: PMC9324298 DOI: 10.3390/pharmaceutics14071493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/11/2022] [Accepted: 07/13/2022] [Indexed: 11/26/2022] Open
Abstract
Honey has been widely purported as a natural remedy due to its antimicrobial and anti-inflammatory effects. In recent years, several studies have suggested that the considerably high methylglyoxal (MGO) concentration in Mānuka honey (MH) makes it particularly effective to manage bacterial overload, such as that observed in blepharitis. However, the poor solubility, high viscosity, and osmolarity of aqueous honey solutions, especially at the high MGO concentrations studied in the literature, render the formulation of an acceptable dosage form for topical application to the eyelids challenging. Here, the antibacterial properties of raw MH and alpha-cyclodextrin (α-CD)-complexed MH were evaluated at relatively low MGO concentrations, and a liquid crystalline-forming microemulsion containing α-CD-complexed MH was formulated. After determining pH and osmolarity, ocular tolerability was assessed using human primary corneal epithelial cells and chorioallantoic membranes, while the antibacterial efficacy was further evaluated in vitro. The α-CD–MH complex had significantly greater antibacterial activity against Staphylococcus aureus than either constituent alone, which was evident even when formulated as a microemulsion. Moreover, the final formulation had a physiologically acceptable pH and osmolarity for eyelid application and was well-tolerated when diluted 1:10 with artificial tear fluid, as expected to be the case after accidental exposure to the ocular surface in the clinical setting. Thus, a safe and efficient MH dosage form was developed for topical application to the eyelids, which can potentially be used to support optimal eyelid health in the management of blepharitis.
Collapse
|
5
|
Budai P, Kormos É, Buda I, Somody G, Lehel J. Comparative evaluation of HET-CAM and ICE methods for objective assessment of ocular irritation caused by selected pesticide products. Toxicol In Vitro 2021; 74:105150. [PMID: 33753176 DOI: 10.1016/j.tiv.2021.105150] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 03/15/2021] [Accepted: 03/17/2021] [Indexed: 01/29/2023]
Abstract
Eye irritation potency of pesticides (fungicides, herbicides, insecticides) was comparatively tested by HET-CAM and ICE method. Based on the results of the tests the statistical analysis of agreement between classification using individual methods was done by Goodman-Kruskal's rank correlation and determination (calculation) of Cohen's kappa coefficient. Statistical analysis of agreement between classification revealed significant correlation between results of in vivo and in HET-CAM assays (76%). There was no significant correlation between result of in vivo and in ICE methods (64%). Weakest correlation was found between the data from in vitro HET-CAM and ICE tests. The percentage of agreement between two in vitro data was 48%. They may be recommended as a part of a battery of tests to reduce experimentation on mammals and to limit or eliminate pain and injury inflicted on experimental animals. The HET-CAM test is a useful tool for studying in vivo the potential conjunctival irritation, while the ICE test can be used to study corneal irritant effects in detail.
Collapse
Affiliation(s)
- Péter Budai
- Georgikon Campus, Hungarian University of Agriculture and Life Sciences, Hungary.
| | - Éva Kormos
- Georgikon Campus, Hungarian University of Agriculture and Life Sciences, Hungary
| | - István Buda
- Georgikon Campus, Hungarian University of Agriculture and Life Sciences, Hungary
| | - Gergő Somody
- Georgikon Campus, Hungarian University of Agriculture and Life Sciences, Hungary
| | - József Lehel
- University of Veterinary Medicine Budapest, Hungary.
| |
Collapse
|
6
|
Sandner G, König A, Wallner M, Weghuber J. Alternative model organisms for toxicological fingerprinting of relevant parameters in food and nutrition. Crit Rev Food Sci Nutr 2021; 62:5965-5982. [PMID: 33683153 DOI: 10.1080/10408398.2021.1895060] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In the field of (food) toxicology, there is a strong trend of replacing animal trials with alternative methods for the assessment of adverse health effects in humans. The replacement of animal trials is not only driven by ethical concerns but also by the number of potential testing substances (food additives, packaging material, contaminants, and toxicants), which is steadily increasing. In vitro 2D cell culture applications in combination with in silico modeling might provide an applicable first response. However, those systems lack accurate predictions of metabolic actions. Thus, alternative in vivo models could fill the gap between cell culture and animal trials. In this review, we highlight relevant studies in the field and spotlight the applicability of alternative models, including C. elegans, D. rerio, Drosophila, HET-CAM and Lab-on-a-chip.
Collapse
Affiliation(s)
- Georg Sandner
- Center of Excellence Food Technology and Nutrition, University of Applied Sciences Upper Austria, Wels, Austria
| | - Alice König
- Center of Excellence Food Technology and Nutrition, University of Applied Sciences Upper Austria, Wels, Austria.,FFoQSI GmbH-Austrian Competence Centre for Feed and Food Quality, Safety and Innovation, Tulln, Austria
| | - Melanie Wallner
- Center of Excellence Food Technology and Nutrition, University of Applied Sciences Upper Austria, Wels, Austria.,FFoQSI GmbH-Austrian Competence Centre for Feed and Food Quality, Safety and Innovation, Tulln, Austria
| | - Julian Weghuber
- Center of Excellence Food Technology and Nutrition, University of Applied Sciences Upper Austria, Wels, Austria.,FFoQSI GmbH-Austrian Competence Centre for Feed and Food Quality, Safety and Innovation, Tulln, Austria
| |
Collapse
|
7
|
Moe B, Berezowski KL, Huang DY, Dey I, Xie L, Ling ZC, Kinniburgh DW. A microelectric cell sensing technique for in vitro assessment of ocular irritation. Toxicol In Vitro 2021; 73:105124. [PMID: 33636280 DOI: 10.1016/j.tiv.2021.105124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 01/16/2021] [Accepted: 02/18/2021] [Indexed: 10/22/2022]
Abstract
The animal-based Draize test remains the gold standard for assessment of ocular irritation. However, subjective scoring methods, species differences, and animal welfare concerns have spurred development of alternative test methods. In this study, a novel in vitro method for assessing ocular irritancy was developed using a microelectric cell sensing technology, real-time cell analysis (RTCA). The cytotoxicity of sixteen compounds was assessed in two cell lines: ARPE-19 (human retina) and SIRC (rabbit cornea). In vitro inhibitory (IC50 and AUC50) values were determined at 6, 12, 24, 48, 72, and 96 h exposure, with a subset of values confirmed with MTT testing. The values displayed comparable predictivity of in vivo ocular irritation on the basis of a linear regression between the calculated values and each compounds' corresponding Draize-determined modified maximum average score (MMAS), but the ARPE-19 derived values were more strongly correlated than those from SIRC cells. Hence, IC50 values derived from ARPE-19 cells were used to predict the UN GHS/EU CLP classification of each test compound. The method was determined to have sensitivity of 90%, specificity of 50%, and overall concordance of 75%. Thus, RTCA testing may be best incorporated into a top-down tiered testing strategy for identification of ocular irritants in vitro.
Collapse
Affiliation(s)
- Birget Moe
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Kathryn L Berezowski
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Dorothy Yu Huang
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada.
| | - Indranil Dey
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Li Xie
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Zong-Chao Ling
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - David W Kinniburgh
- Alberta Centre for Toxicology, Department of Physiology & Pharmacology, Faculty of Medicine, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| |
Collapse
|
8
|
Development of In Vitro Corneal Models: Opportunity for Pharmacological Testing. Methods Protoc 2020; 3:mps3040074. [PMID: 33147693 PMCID: PMC7711486 DOI: 10.3390/mps3040074] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 10/30/2020] [Indexed: 12/12/2022] Open
Abstract
The human eye is a specialized organ with a complex anatomy and physiology, because it is characterized by different cell types with specific physiological functions. Given the complexity of the eye, ocular tissues are finely organized and orchestrated. In the last few years, many in vitro models have been developed in order to meet the 3Rs principle (Replacement, Reduction and Refinement) for eye toxicity testing. This procedure is highly necessary to ensure that the risks associated with ophthalmic products meet appropriate safety criteria. In vitro preclinical testing is now a well-established practice of significant importance for evaluating the efficacy and safety of cosmetic, pharmaceutical, and nutraceutical products. Along with in vitro testing, also computational procedures, herein described, for evaluating the pharmacological profile of potential ocular drug candidates including their toxicity, are in rapid expansion. In this review, the ocular cell types and functionality are described, providing an overview about the scientific challenge for the development of three-dimensional (3D) in vitro models.
Collapse
|
9
|
Ceriotti L, Balzaretti S, Barone S, Meloni M. Eye Irritation Potential of Microglycine and Microglycine-Containing Ointments: An in vitro Study on Reconstructed Human Corneal Epithelium. Clin Ophthalmol 2020; 14:257-267. [PMID: 32158183 PMCID: PMC6986405 DOI: 10.2147/opth.s229879] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/19/2019] [Indexed: 12/19/2022] Open
Abstract
Objective To assess the eye tolerability of a buffered ophthalmic solution containing microglycine (sodium hydroxymethylglycinate, mwaterTM) in an in vitro model. Materials and Methods A multiple endpoint analysis (MEA) approach was applied to the reconstructed human corneal epithelium (HCE) model. Sodium hydroxymethylglycinate solution (0.04%) and two ophthalmic ointments containing microglycine (Protectorial, containing 0.02% of sodium hydroxymethylglycinate, and Edenight, containing 0.04% of sodium hydroxymethylglycinate) were investigated. The buffered solution and the ointments were tested on HCE after acute (one application in 24 hrs, followed or not by 16 hrs of recovery) or repeated (one application per day for three consecutive days) exposures; benzalkonium chloride (BAK) 0.01% and saline isotonic solution were used as positive and negative controls, respectively. Cellular viability, trans-epithelial electrical resistance (TEER), lactate dehydrogenase (LDH) release and histo-morphology were evaluated. Results BAK 0.01% toxicity in HCE was confirmed for the 24+16 hrs acute and repeated exposure protocols, while, after 24–hours acute treatment, only modifications of the superficial cell layer were visible compared with the negative control. Sodium hydroxymethylglycinate had a very good tolerability profile and a neutral impact on the corneal surface after acute or repeated exposure. The Protectorial and Edenight ointments preserved cell viability in the different exposure protocols, suggesting a good local tolerability profile. Modifications of the superficial layers were observed on histo-morphological analysis and confirmed by increased release of LDH after 24+16 hrs acute exposure (+65% and +76% for Protectorial and Edenight, respectively) and TEER values after 24+16 hrs and 72 hrs exposure protocols. These results were dependent on the ointments’ accumulation on the corneal epithelium due to their physical form (semi-solid) and lipophilic properties. Conclusion Sodium hydroxymethylglycinate, alone or as part of eye ointments, was found to be non-toxic after acute or repeated exposure in the reconstructed HCE model.
Collapse
|
10
|
Revisiting the effects of menopause on the skin: Functional changes, clinical studies, in vitro models and therapeutic alternatives. Mech Ageing Dev 2019; 185:111193. [PMID: 31811831 DOI: 10.1016/j.mad.2019.111193] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 11/22/2019] [Accepted: 12/02/2019] [Indexed: 02/07/2023]
Abstract
Menopause is a stage in a woman's life characterized by twelve months of amenorrhoea. This transition happens due to changes in ovarian follicular activity, leading to endocrine, biological and clinical modifications. The main hormones related to these changes and symptoms are oestradiol, LH, FSH, AMH, Inhibin B and GnRH. It is important to point out that the skin is very affected by all these hormone changes, leading to a decrease in collagen content, water content, elasticity, thickness and impacting on all skin layers quality. Aiming to help women go through this period of their lifetimes with a better quality of life, cosmetic and pharmaceutical industries have studied formulations to improve skin quality. In order to study the safety and efficacy of these products, in vitro methods have been developed in order to mimic menopause and aged skin. In addition to that, many clinical methodologies for skin features assessment have also been improved and applied to evaluate the efficacy of treatments or compounds for menopause. Studying and improving skin models and skin evaluation methodologies may help in the identification of therapeutic targets, treatments, drugs and cosmetics along with new insights for future research in the dermatology field.
Collapse
|
11
|
Medical devices biocompatibility assessment on HCE: Evidences of delayed cytotoxicity of preserved compared to preservative free eye drops. Regul Toxicol Pharmacol 2019; 106:81-89. [DOI: 10.1016/j.yrtph.2019.04.022] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 04/16/2019] [Accepted: 04/26/2019] [Indexed: 11/21/2022]
|
12
|
Abo T, Yuki T, Xu R, Araki D, Takahashi Y, Sakaguchi H, Itagaki H. Expansion of the applicability domain for highly volatile substances on the Short Time Exposure test method and the predictive performance in assessing eye irritation potential. J Toxicol Sci 2018; 43:407-422. [PMID: 29973473 DOI: 10.2131/jts.43.407] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
The Short Time Exposure (STE) test method is an in vitro method for assessing the eye irritation potential of chemicals and is used to classify the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) Category 1 and No Category (NC). The method has been adopted by the Organisation for Economic Co-operation and Development (OECD) as test guideline (TG) 491 since 2015. While this method can be used to classify GHS NC, it is not suitable for testing highly volatile substances and solids other than surfactants. Here we evaluated highly volatile substances to expand the applicability domain. According to TG 491, acetone, ethanol, iso-propanol, and methyl acetate as highly volatile substances resulted in false negatives. Saline was selected as a solvent of these false negatives. In this study, mineral oil was used as the solvent, because these false negatives were amphiphilic. Based on this change, four highly volatile substances were correctly evaluated. The predictive performance for classifying GHS NC was then verified using a substance dataset constructed in reference to the Draize eye test Reference Database and STE Summary Review Document. The accuracy and false-negative rate were 86.6% (194/224) and 3.8% (3/80), respectively. Collectively, the applicability domain was expanded by changing the solvent to mineral oil for highly volatile substances, and the predictive performance for the new applicability domain including highly volatile substances was excellent. The STE test method is suitable to classify GHS NC, indicating its applicability as a test method in a bottom-up approach.
Collapse
Affiliation(s)
- Takayuki Abo
- Kao Corporation, Safety Science Research Laboratories.,Faculty of Engineering, Department of Materials Science and Engineering, Yokohama National University
| | - Takuo Yuki
- Kao Corporation, Safety Science Research Laboratories
| | - Rui Xu
- Kao Corporation, Safety Science Research Laboratories
| | - Daisuke Araki
- Kao Corporation, Safety Science Research Laboratories
| | | | | | - Hiroshi Itagaki
- Faculty of Engineering, Department of Materials Science and Engineering, Yokohama National University
| |
Collapse
|
13
|
Bioengineering of a Full-Thickness Skin Equivalent in a 96-Well Insert Format for Substance Permeation Studies and Organ-On-A-Chip Applications. Bioengineering (Basel) 2018; 5:bioengineering5020043. [PMID: 29880746 PMCID: PMC6027510 DOI: 10.3390/bioengineering5020043] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Revised: 05/30/2018] [Accepted: 06/01/2018] [Indexed: 12/24/2022] Open
Abstract
The human skin is involved in protecting the inner body from constant exposure to outer environmental stimuli. There is an evident need to screen for toxicity and the efficacy of drugs and cosmetics applied to the skin. To date, animal studies are still the standard method for substance testing, although they are currently controversially discussed Therefore, the multi-organ chip is an attractive alternative to replace animal testing. The two-organ chip is designed to hold 96-well cell culture inserts (CCIs). Small-sized skin equivalents are needed for this. In this study, full-thickness skin equivalents (ftSEs) were generated successfully inside 96-well CCIs. These skin equivalents developed with in vivo-like histological architecture, with normal differentiation marker expressions and proliferation rates. The 96-well CCI-based ftSEs were successfully integrated into the two-organ chip. The permeation of fluorescein sodium salt through the ftSEs was monitored during the culture. The results show a decreasing value for the permeation over time, which seems a promising method to track the development of the ftSEs. Additionally, the permeation was implemented in a computational fluid dynamics simulation, as a tool to predict results in long-term experiments. The advantage of these ftSEs is the reduced need for cells and substances, which makes them more suitable for high throughput assays.
Collapse
|
14
|
Predictive performance and inter-laboratory reproducibility in assessing eye irritation potential of water- and oil-soluble mixtures using the Short Time Exposure test method. Toxicol In Vitro 2018; 48:78-85. [DOI: 10.1016/j.tiv.2017.12.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Revised: 11/07/2017] [Accepted: 12/28/2017] [Indexed: 11/17/2022]
|
15
|
Truong L, Ouedraogo G, Pham L, Clouzeau J, Loisel-Joubert S, Blanchet D, Noçairi H, Setzer W, Judson R, Grulke C, Mansouri K, Martin M. Predicting in vivo effect levels for repeat-dose systemic toxicity using chemical, biological, kinetic and study covariates. Arch Toxicol 2018; 92:587-600. [PMID: 29075892 PMCID: PMC5818596 DOI: 10.1007/s00204-017-2067-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 09/18/2017] [Indexed: 11/29/2022]
Abstract
In an effort to address a major challenge in chemical safety assessment, alternative approaches for characterizing systemic effect levels, a predictive model was developed. Systemic effect levels were curated from ToxRefDB, HESS-DB and COSMOS-DB from numerous study types totaling 4379 in vivo studies for 1247 chemicals. Observed systemic effects in mammalian models are a complex function of chemical dynamics, kinetics, and inter- and intra-individual variability. To address this complex problem, systemic effect levels were modeled at the study-level by leveraging study covariates (e.g., study type, strain, administration route) in addition to multiple descriptor sets, including chemical (ToxPrint, PaDEL, and Physchem), biological (ToxCast), and kinetic descriptors. Using random forest modeling with cross-validation and external validation procedures, study-level covariates alone accounted for approximately 15% of the variance reducing the root mean squared error (RMSE) from 0.96 log10 to 0.85 log10 mg/kg/day, providing a baseline performance metric (lower expectation of model performance). A consensus model developed using a combination of study-level covariates, chemical, biological, and kinetic descriptors explained a total of 43% of the variance with an RMSE of 0.69 log10 mg/kg/day. A benchmark model (upper expectation of model performance) was also developed with an RMSE of 0.5 log10 mg/kg/day by incorporating study-level covariates and the mean effect level per chemical. To achieve a representative chemical-level prediction, the minimum study-level predicted and observed effect level per chemical were compared reducing the RMSE from 1.0 to 0.73 log10 mg/kg/day, equivalent to 87% of predictions falling within an order-of-magnitude of the observed value. Although biological descriptors did not improve model performance, the final model was enriched for biological descriptors that indicated xenobiotic metabolism gene expression, oxidative stress, and cytotoxicity, demonstrating the importance of accounting for kinetics and non-specific bioactivity in predicting systemic effect levels. Herein, we generated an externally predictive model of systemic effect levels for use as a safety assessment tool and have generated forward predictions for over 30,000 chemicals.
Collapse
Affiliation(s)
- Lisa Truong
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
- Currently at Oregon State University, Corvallis, USA
| | - Gladys Ouedraogo
- L'Oréal Safety Research Department, 1 Avenue E. Schueller, 93600, Aulnay-Sous-Bois, France
| | - LyLy Pham
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
| | - Jacques Clouzeau
- L'Oréal Safety Research Department, 1 Avenue E. Schueller, 93600, Aulnay-Sous-Bois, France
| | - Sophie Loisel-Joubert
- L'Oréal Safety Research Department, 1 Avenue E. Schueller, 93600, Aulnay-Sous-Bois, France
| | - Delphine Blanchet
- L'Oréal Safety Research Department, 1 Avenue E. Schueller, 93600, Aulnay-Sous-Bois, France
| | - Hicham Noçairi
- L'Oréal Safety Research Department, 1 Avenue E. Schueller, 93600, Aulnay-Sous-Bois, France
| | - Woodrow Setzer
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
| | - Richard Judson
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
| | - Chris Grulke
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
| | - Kamel Mansouri
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
- Currently at Scitovation LLC, Research Triangle Park, NC, USA
| | - Matthew Martin
- National Center for Computational Toxicology, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, 27711, USA.
- Currently at Pfizer, Inc, Drug Safety Research and Development, 445 Eastern Point Road, MS 8274-1224, Groton, CT, 06340, USA.
| |
Collapse
|
16
|
Alternative Methods to Animal Testing for the Safety Evaluation of Cosmetic Ingredients: An Overview. COSMETICS 2017. [DOI: 10.3390/cosmetics4030030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
The safety of cosmetics sold in Europe is based on the safety evaluation of each individual ingredient conducted by those responsible for putting the product on the market. However, those substances for which some concern exists with respect to human health (e.g., colorants, preservatives, UV-filters, nanomaterials) are evaluated at the European Commission level by a scientific committee, currently called the Scientific Committee on Consumer Safety (SCCS). According to the Cosmetics Regulation (European Commission, 2009), it is prohibited in the European Union (EU) to market cosmetic products and ingredients that have been tested on animals. However, the results of studies performed before the ban continue to be accepted. In the current study, we evaluated the use of in vitro methods in the dossiers submitted to the SCCS in the period between 2013 and 2016 based on the published reports issued by the scientific committee, which provides a scientific opinion on these dossiers. The results of this evaluation were compared with those of an evaluation conducted four years previously. We found that, despite a slight increase in the number of studies performed in vitro, the majority of studies submitted to the SCCS is still done principally in vivo and correspond to studies performed before the ban.
Collapse
|
17
|
Destruel PL, Zeng N, Maury M, Mignet N, Boudy V. In vitro and in vivo evaluation of in situ gelling systems for sustained topical ophthalmic delivery: state of the art and beyond. Drug Discov Today 2017; 22:638-651. [DOI: 10.1016/j.drudis.2016.12.008] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 11/18/2016] [Accepted: 12/15/2016] [Indexed: 10/20/2022]
|
18
|
Kim SW, Kim BH. A Web-based Alternative Non-animal Method Database for Safety Cosmetic Evaluations. Toxicol Res 2016; 32:259-67. [PMID: 27437094 PMCID: PMC4946419 DOI: 10.5487/tr.2016.32.3.259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 04/05/2016] [Accepted: 04/11/2016] [Indexed: 11/20/2022] Open
Abstract
Animal testing was used traditionally in the cosmetics industry to confirm product safety, but has begun to be banned; alternative methods to replace animal experiments are either in development, or are being validated, worldwide. Research data related to test substances are critical for developing novel alternative tests. Moreover, safety information on cosmetic materials has neither been collected in a database nor shared among researchers. Therefore, it is imperative to build and share a database of safety information on toxicological mechanisms and pathways collected through in vivo, in vitro, and in silico methods. We developed the CAMSEC database (named after the research team; the Consortium of Alternative Methods for Safety Evaluation of Cosmetics) to fulfill this purpose. On the same website, our aim is to provide updates on current alternative research methods in Korea. The database will not be used directly to conduct safety evaluations, but researchers or regulatory individuals can use it to facilitate their work in formulating safety evaluations for cosmetic materials. We hope this database will help establish new alternative research methods to conduct efficient safety evaluations of cosmetic materials.
Collapse
Affiliation(s)
- Seung Won Kim
- Major in Public Health, Faculty of Food and Health Sciences, Keimyung University, Daegu, Korea
| | - Bae-Hwan Kim
- Major in Public Health, Faculty of Food and Health Sciences, Keimyung University, Daegu, Korea
| |
Collapse
|
19
|
Assessment of the eye irritation potential of chemicals: A comparison study between two test methods based on human 3D hemi-cornea models. Toxicol In Vitro 2015; 30:561-8. [PMID: 26362509 DOI: 10.1016/j.tiv.2015.09.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 09/02/2015] [Accepted: 09/06/2015] [Indexed: 11/21/2022]
Abstract
We have recently developed two hemi-cornea models (Bartok et al., Toxicol in Vitro 29, 72, 2015; Zorn-Kruppa et al. PLoS One 9, e114181, 2014), which allow the correct prediction of eye irritation potential of chemicals according to the United Nations globally harmonized system of classification and labeling of chemicals (UN GHS). Both models comprise a multilayered epithelium and a stroma with embedded keratocytes in a collagenous matrix. These two models were compared, using a set of fourteen test chemicals. Their effects after 10 and 60 minutes (min) exposure were assessed from the quantification of cell viability using the MTT reduction assay. The first approach separately quantifies the damage inflicted to the epithelium and the stroma. The second approach quantifies the depth of injury by recording cell death as a function of depth. The classification obtained by the two models was compared to the Draize rabbit eye test and an ex vivo model using rabbit cornea (Jester et al. Toxicol in Vitro. 24, 597-604, 2010). With a 60 min exposure, both of our models are able to clearly differentiate UN GHS Category 1 and UN GHS Category 2 test chemicals.
Collapse
|
20
|
Development of an in vitro cytotoxicity model for aerosol exposure using 3D reconstructed human airway tissue; application for assessment of e-cigarette aerosol. Toxicol In Vitro 2015; 29:1952-62. [DOI: 10.1016/j.tiv.2015.05.018] [Citation(s) in RCA: 104] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Revised: 04/07/2015] [Accepted: 05/23/2015] [Indexed: 11/18/2022]
|
21
|
Abdelkader H, Pierscionek B, Carew M, Wu Z, Alany RG. Critical appraisal of alternative irritation models: three decades of testing ophthalmic pharmaceuticals. Br Med Bull 2015; 113:59-71. [PMID: 25686845 DOI: 10.1093/bmb/ldv002] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Testing ocular tolerability of ocular pharmaceuticals is an essential regulatory requirement. The current approved reference model (gold standard) for ocular irritation testing is the Draize test. However this method is subjective and involves using live animals, hence the need to develop alternative in vitro and ex vivo testing strategies. SOURCE OF DATA Pubmed, Science Direct, Scopus, Google Scholar, Medline, Current Content, Web of Science and validation reports from international regulatory bodies; The Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) and European Centre for the Validation of Alternative Methods (ECVAM) were searched for in vitro alternatives. AREA OF AGREEMENT Whilst no single in vitro test can effectively replace the Draize eye irritation test, regulatory bodies and cosmetic/pharmaceutical industries agree that there is a need for in vitro alternatives with validated endpoints to evaluate pharmaceutical ingredients and finished eye products. AREA OF CONTROVERSY There is no single in vitro test / assay that can predict the ocular irritation potential of mild to moderate test substances. AREA TIMELY FOR DEVELOPING RESEARCH This review provides a critical appraisal of the selected in vitro and ex vivo ocular toxicity models recommended by international regulatory bodies. These include cytotoxicity methods, biochemical systems and ex vivo assays. The latter are approved by ECVAM as in vitro alternatives for the well-known Draize test. Hen's egg test-chorioallantoic membrane and the isolated rabbit eye test are also accepted by regulatory agencies in France, Germany, the Netherlands and the UK. A combination of ex vivo assays along with histological examination of excised bovine cornea can predict the conjunctival and corneal tolerability and cover a wider range of ocular pharmaceutical substances.
Collapse
Affiliation(s)
- Hamdy Abdelkader
- Faculty of Science, Engineering and Computing, Kingston University London, Kingston upon Thames, UK Department of Pharmaceutics, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Barbara Pierscionek
- Faculty of Science, Engineering and Computing, Kingston University London, Kingston upon Thames, UK
| | - Mark Carew
- Faculty of Science, Engineering and Computing, Kingston University London, Kingston upon Thames, UK
| | - Zimei Wu
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Raid G Alany
- Faculty of Science, Engineering and Computing, Kingston University London, Kingston upon Thames, UK School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
22
|
Vinardell M. The use of non-animal alternatives in the safety evaluations of cosmetics ingredients by the Scientific Committee on Consumer Safety (SCCS). Regul Toxicol Pharmacol 2015; 71:198-204. [DOI: 10.1016/j.yrtph.2014.12.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 12/19/2014] [Accepted: 12/20/2014] [Indexed: 01/08/2023]
|
23
|
Bartok M, Gabel D, Zorn-Kruppa M, Engelke M. Development of an in vitro ocular test system for the prediction of all three GHS categories. Toxicol In Vitro 2015; 29:72-80. [DOI: 10.1016/j.tiv.2014.09.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 09/03/2014] [Accepted: 09/05/2014] [Indexed: 11/28/2022]
|
24
|
Zorn-Kruppa M, Houdek P, Wladykowski E, Engelke M, Bartok M, Mewes KR, Moll I, Brandner JM. Determining the Depth of Injury in Bioengineered Tissue Models of Cornea and Conjunctiva for the Prediction of All Three Ocular GHS Categories. PLoS One 2014; 9:e114181. [PMID: 25494045 PMCID: PMC4262406 DOI: 10.1371/journal.pone.0114181] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2014] [Accepted: 11/05/2014] [Indexed: 11/19/2022] Open
Abstract
The depth of injury (DOI) is a mechanistic correlate to the ocular irritation response. Attempts to quantitatively determine the DOI in alternative tests have been limited to exvivo animal eyes by fluorescent staining for biomarkers of cell death and viability in histological cross sections. It was the purpose of this study to assess whether DOI could also be measured by means of cell viability detected by the MTT assay using 3-dimensional (3D) reconstructed models of cornea and conjunctiva. The formazan-free area of metabolically inactive cells in the tissue after topical substance application is used as the visible correlate of the DOI. Areas of metabolically active or inactive cells are quantitatively analyzed on cryosection images with ImageJ software analysis tools. By incorporating the total tissue thickness, the relative MTT-DOI (rMTT-DOI) was calculated. Using the rMTT-DOI and human reconstructed cornea equivalents, we developed a prediction model based on suitable viability cut-off values. We tested 25 chemicals that cover the whole range of eye irritation potential based on the globally harmonized system of classification and labelling of chemicals (GHS). Principally, the MTT-DOI test method allows distinguishing between the cytotoxic effects of the different chemicals in accordance with all 3 GHS categories for eye irritation. Although the prediction model is slightly over-predictive with respect to non-irritants, it promises to be highly valuable to discriminate between severe irritants (Cat. 1), and mild to moderate irritants (Cat. 2). We also tested 3D conjunctiva models with the aim to specifically address conjunctiva-damaging substances. Using the MTT-DOI method in this model delivers comparable results as the cornea model, but does not add additional information. However, the MTT-DOI method using reconstructed cornea models already provided good predictability that was superior to the already existing established invitro/exvivo methods.
Collapse
Affiliation(s)
- Michaela Zorn-Kruppa
- University Medical Center Hamburg-Eppendorf, Department of Dermatology and Venerology, 20246 Hamburg, Germany
- * E-mail:
| | - Pia Houdek
- University Medical Center Hamburg-Eppendorf, Department of Dermatology and Venerology, 20246 Hamburg, Germany
| | - Ewa Wladykowski
- University Medical Center Hamburg-Eppendorf, Department of Dermatology and Venerology, 20246 Hamburg, Germany
| | - Maria Engelke
- Jacobs University Bremen gGmbH, School of Engineering and Sciences, 28759 Bremen, Germany
| | - Melinda Bartok
- Jacobs University Bremen gGmbH, School of Engineering and Sciences, 28759 Bremen, Germany
| | | | - Ingrid Moll
- University Medical Center Hamburg-Eppendorf, Department of Dermatology and Venerology, 20246 Hamburg, Germany
| | - Johanna M. Brandner
- University Medical Center Hamburg-Eppendorf, Department of Dermatology and Venerology, 20246 Hamburg, Germany
| |
Collapse
|
25
|
Wroblewska K, Kucinska M, Murias M, Lulek J. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests. Saudi Pharm J 2014; 23:407-12. [PMID: 27134543 PMCID: PMC4834719 DOI: 10.1016/j.jsps.2014.11.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Accepted: 11/29/2014] [Indexed: 11/09/2022] Open
Abstract
The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).
Collapse
Affiliation(s)
- Katarzyna Wroblewska
- Department of Pharmaceutical Technology, Poznan University of Medical Sciences, 6 Grunwaldzka Street, 60-780 Poznan, Poland
| | - Małgorzata Kucinska
- Department of Toxicology, Poznan University of Medical Sciences, 30 Dojazd Street, 60-631 Poznan, Poland
| | - Marek Murias
- Department of Toxicology, Poznan University of Medical Sciences, 30 Dojazd Street, 60-631 Poznan, Poland
| | - Janina Lulek
- Department of Pharmaceutical Technology, Poznan University of Medical Sciences, 6 Grunwaldzka Street, 60-780 Poznan, Poland
| |
Collapse
|
26
|
Hayashi K, Abo T, Nukada Y, Sakaguchi H. Definition of the applicability domain of the Short Time Exposure (STE) test for predicting the eye irritation of chemicals. Altern Lab Anim 2013; 41:157-71. [PMID: 23781933 DOI: 10.1177/026119291304100205] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The Short Time Exposure (STE) test is a simple and easy-to-perform in vitro eye irritation test, that uses the viability of SIRC cells (a rabbit corneal cell line) treated for five minutes as the endpoint. In this study, our goal was to define the applicability domain of the STE test, based on the results obtained with a set of 113 substances. To achieve this goal, chemicals were selected to represent both different chemical classes and different chemical properties, as well as to cover, in a balanced manner, the categories of eye irritation potential according to the Globally Harmonised System (GHS). Accuracy analysis indicated that the rates of false negatives for organic/inorganic salts (75.0%), hydrocarbons (33.3%) and alcohols (23.5%) were high. Many of the false negative results were for solid substances. It is noteworthy that no surfactant resulted in a false negative result in the STE test. Further examination of the physical property data and performance showed a significant improvement in the predictive accuracy, when substances with vapour pressures over 6kPa were excluded from the analyses. Our results indicate that several substances - i.e. certain solids such as salts, alcohols, hydrocarbons, and volatile substances with a vapour pressure over 6kPa - do not fall within the applicability domain of the STE test. Overall, we are encouraged by the performance and improved accuracy of the STE test.
Collapse
Affiliation(s)
- Kazuhiko Hayashi
- Safety Science Research Laboratories, Kao Corporation, Ichikai-Machi, Haga-Gun, Tochigi, Japan
| | | | | | | |
Collapse
|
27
|
Second-phase validation study of short time exposure test for assessment of eye irritation potency of chemicals. Toxicol In Vitro 2013; 27:1855-69. [PMID: 23747838 DOI: 10.1016/j.tiv.2013.05.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2012] [Revised: 04/22/2013] [Accepted: 05/15/2013] [Indexed: 11/23/2022]
Abstract
A Short Time Exposure (STE) test is a cytotoxicity test that uses SIRC cells (rabbit corneal cell line) to assess eye irritation potency following a 5-min chemical exposure. This second-phase validation study assessed the predictive capacity of the STE test using 40 coded test substances at three laboratories. A Validation Management Team (VMT) then evaluated the predictivity of the STE test for United Nation (UN) Globally Harmonized System (GHS) categories using 63 test substances including the results of the first-phase validation study. The STE test can assess not only the severe or corrosive ocular irritants (corresponding to the UN GHS Category 1) but also non-irritant (corresponding to UN GHS Non Category) from other toxicity classes, especially for limited types of test substances. The predictivity by STE test, however, was insufficient for identification of UN GHS categories (Category 1, Category 2, or Non Category). These results suggest that the STE test can be recommended as an initial step in a top-down approach to identification of severe irritants and test substances that require classification for eye irritation (UN GHS Category 1) as well as an initial step in a bottom-up approach to identification of test substances that do not require classification for eye irritation (UN GHS Non Category) from other toxicity classes, especially for limited types of test substances. On the other hand, the STE test is not considered adequate for the identification of mild or moderate irritants (i.e., UN GHS Categories 2A and 2B) and severe irritants (UN GHS Category 1).
Collapse
|
28
|
Dholakiya SL, Barile FA. Alternative methods for ocular toxicology testing: validation, applications and troubleshooting. Expert Opin Drug Metab Toxicol 2013; 9:699-712. [DOI: 10.1517/17425255.2013.783013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
29
|
Rahimi M, Youn HY, McCanna DJ, Sivak JG, Mikkelsen SR. Application of cyclic biamperometry to viability and cytotoxicity assessment in human corneal epithelial cells. Anal Bioanal Chem 2013; 405:4975-9. [PMID: 23443523 DOI: 10.1007/s00216-013-6843-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Revised: 02/11/2013] [Accepted: 02/13/2013] [Indexed: 10/27/2022]
Abstract
The application of cyclic biamperometry to viability and cytotoxicity assessments of human corneal epithelial cells has been investigated. Electrochemical measurements have been compared in PBS containing 5.0 mM glucose and minimal essential growth medium. Three different lipophilic mediators including dichlorophenol indophenol, 2-methyl-1,4-naphthoquinone (also called menadione or vitamin K3) and N,N,N',N'-tetramethyl-p-phenylenediamine have been evaluated for shuttling electrons across the cell membrane to the external medium. Transfer of these electrons to ferricyanide in the extra cellular medium results in the accumulation of ferrocyanide. The amount of ferrocyanide is then determined using cyclic biamperometry and is related to the extent of cell metabolic activity and therefore cell viability. To illustrate cytotoxicity assessment of chemicals, hydrogen peroxide, benzalkonium chloride and sodium dodecyl sulfate have been chosen as sample toxins, the cytotoxicities of which have been evaluated and compared to values reported in the literature. Similar values have been reported using colorimetric assays; however, the simplicity of this electrochemical assay can, in principle, open the way to miniaturization onto lab-on-chip devices and its incorporation into tiered-testing approaches for cytotoxicity assessment.
Collapse
Affiliation(s)
- Mehdi Rahimi
- Department of Chemistry and Biochemistry, University of Waterloo, Waterloo, ON, Canada.
| | | | | | | | | |
Collapse
|
30
|
Engelke M, Zorn-Kruppa M, Gabel D, Reisinger K, Rusche B, Mewes K. A human hemi-cornea model for eye irritation testing: Quality control of production, reliability and predictive capacity. Toxicol In Vitro 2013; 27:458-68. [DOI: 10.1016/j.tiv.2012.07.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2011] [Revised: 07/08/2012] [Accepted: 07/30/2012] [Indexed: 10/28/2022]
|
31
|
Surfactants: Chemistry, Toxicity and Remediation. ENVIRONMENTAL CHEMISTRY FOR A SUSTAINABLE WORLD 2013. [DOI: 10.1007/978-3-319-02387-8_5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
32
|
Hartung T, Luechtefeld T, Maertens A, Kleensang A. Integrated testing strategies for safety assessments. ALTEX 2013; 30:3-18. [PMID: 23338803 PMCID: PMC3800026 DOI: 10.14573/altex.2013.1.003] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Despite the fact that toxicology uses many stand-alone tests, a systematic combination of several information sources very often is required: Examples include: when not all possible outcomes of interest (e.g., modes of action), classes of test substances (applicability domains), or severity classes of effect are covered in a single test; when the positive test result is rare (low prevalence leading to excessive false-positive results); when the gold standard test is too costly or uses too many animals, creating a need for prioritization by screening. Similarly, tests are combined when the human predictivity of a single test is not satisfactory or when existing data and evidence from various tests will be integrated. Increasingly, kinetic information also will be integrated to make an in vivo extrapolation from in vitro data. Integrated Testing Strategies (ITS) offer the solution to these problems. ITS have been discussed for more than a decade, and some attempts have been made in test guidance for regulations. Despite their obvious potential for revamping regulatory toxicology, however, we still have little guidance on the composition, validation, and adaptation of ITS for different purposes. Similarly, Weight of Evidence and Evidence-based Toxicology approaches require different pieces of evidence and test data to be weighed and combined. ITS also represent the logical way of combining pathway-based tests, as suggested in Toxicology for the 21st Century. This paper describes the state of the art of ITS and makes suggestions as to the definition, systematic combination, and quality assurance of ITS.
Collapse
Affiliation(s)
- Thomas Hartung
- Johns Hopkins University, Bloomberg School of Public Health, CAAT, Baltimore, MD 21205, USA.
| | | | | | | |
Collapse
|
33
|
Westmoreland C, Holmes AM. Assuring consumer safety without animals: Applications for tissue engineering. Organogenesis 2012; 5:67-72. [PMID: 19794902 DOI: 10.4161/org.5.2.9128] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Accepted: 05/29/2009] [Indexed: 12/27/2022] Open
Abstract
Humans are exposed to a variety of chemicals in their everyday lives through interactions with the environment and through the use of consumer products. It is a basic requirement that these products are tested to assure they are safe under normal and reasonably foreseeable conditions of use. Within the European Union, the majority of tests used for generating toxicological data rely on animals. However recent changes in legislation (e.g., 7(th) amendment of the Cosmetics Directive and REACH) are driving researchers to develop and adopt non-animal alternative methods with which to assure human safety. Great strides have been made to this effect, but what other opportunities/technologies exist that could expedite this? Tissue engineering has increasing scope to contribute to replacing animals with scientifically robust alternatives in basic research and safety testing, but is this application of the technology being fully exploited? This review highlights how the consumer products industry is applying tissue engineering to ensure chemicals are safe for human use without using animals, and identifies areas for future development and application of the technology.
Collapse
Affiliation(s)
- Carl Westmoreland
- Safety and Environmental Assurance Centre (SEAC); Unilever; Sharnbrook, Bedfordshire UK
| | | |
Collapse
|
34
|
Two-stage bottom-up tiered approach combining several alternatives for identification of eye irritation potential of chemicals including insoluble or volatile substances. Toxicol In Vitro 2012; 26:1199-208. [DOI: 10.1016/j.tiv.2012.06.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2012] [Revised: 05/21/2012] [Accepted: 06/19/2012] [Indexed: 11/17/2022]
|
35
|
Cho SA, An S, Lee E, Shin K, Cho JC, Lee TR. A new cell-based method for assessing the eye irritation potential of chemicals: An alternative to the Draize test. Toxicol Lett 2012; 212:198-204. [DOI: 10.1016/j.toxlet.2012.05.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 05/02/2012] [Accepted: 05/06/2012] [Indexed: 11/25/2022]
|
36
|
Hayashi K, Mori T, Abo T, Koike M, Takahashi Y, Sakaguchi H, Nishiyama N. A tiered approach combining the short time exposure (STE) test and the bovine corneal opacity and permeability (BCOP) assay for predicting eye irritation potential of chemicals. J Toxicol Sci 2012; 37:269-80. [DOI: 10.2131/jts.37.269] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Affiliation(s)
| | - Taeko Mori
- Safety Science Research Laboratories, Kao Corporation
| | - Takayuki Abo
- Safety Science Research Laboratories, Kao Corporation
| | - Mirei Koike
- Safety Science Research Laboratories, Kao Corporation
| | | | | | | |
Collapse
|
37
|
Takahashi Y, Hayashi K, Abo T, Koike M, Sakaguchi H, Nishiyama N. The Short Time Exposure (STE) test for predicting eye irritation potential: intra-laboratory reproducibility and correspondence to globally harmonized system (GHS) and EU eye irritation classification for 109 chemicals. Toxicol In Vitro 2011; 25:1425-34. [PMID: 21513790 DOI: 10.1016/j.tiv.2011.04.012] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2010] [Revised: 04/01/2011] [Accepted: 04/07/2011] [Indexed: 10/18/2022]
Abstract
Short Time Exposure (STE) test is an easy in vitro eye irritation test that assesses cytotoxicity in SIRC cells (rabbit corneal cell line) following a 5 min dose treatment. To assess intra-laboratory reproducibility, medium control, three vehicles (saline, saline containing 5% (w/w) dimethyl sulfoxide, and mineral oil) and three standard chemicals (sodium lauryl sulfate, calcium thioglycolate, and Tween 80) were evaluated. Assessments were repeated 30 times for vehicles and 18 times for standard chemicals; resulting in almost the same cell viability and a low coefficient of variation value. In addition, the STE eye irritation rankings of three standard chemicals, as calculated on the cell viabilities in 5% and 0.05% solutions were in agreement in all tests. Based on these results, high intra-laboratory reproducibility was confirmed. In addition, the irritation category (irritant and non-irritant) was evaluated for 109 chemicals with STE test, globally harmonized system (GHS) classification, and European Union (EU) classification. The results of the evaluation found the STE classification to have an accuracy with GHS classification of 87% and with EU classification of 83%, which confirmed the excellent correspondence. The correspondence of STE rankings (1, 2, and 3) based on the prediction model by STE test with the eye irritation rankings by GHS (non-irritant, categories 2 and 1) and EU (non-irritant, R36, and R41) was 76% and 71%, respectively. Based on the above results, STE test was considered to be a promising alternative method for assessing eye irritation that has high intra-laboratory reproducibility as well as an excellent predictability of eye irritation.
Collapse
Affiliation(s)
- Yutaka Takahashi
- Safety Science Research Laboratories, Kao Corporation, 2606 Akabane, Ichikai-Machi, Haga-Gun, Tochigi 321-3497, Japan.
| | | | | | | | | | | |
Collapse
|
38
|
Donahue DA, Avalos J, Kaufman LE, Simion FA, Cerven DR. Ocular irritation reversibility assessment for personal care products using a porcine corneal culture assay. Toxicol In Vitro 2011; 25:708-14. [DOI: 10.1016/j.tiv.2010.12.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 11/09/2010] [Accepted: 12/10/2010] [Indexed: 11/26/2022]
|
39
|
Eye irritation potential: usefulness of the HET-CAM under the Globally Harmonized System of classification and labeling of chemicals (GHS). Regul Toxicol Pharmacol 2011; 59:471-92. [PMID: 21310206 DOI: 10.1016/j.yrtph.2011.02.003] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2010] [Revised: 02/01/2011] [Accepted: 02/03/2011] [Indexed: 11/22/2022]
Abstract
Extensive research has been conducted over the past decades to develop alternatives to the rabbit eye irritation test (Draize test) used in a regulatory context to assess eye irritation potentials. Although no single in vitro test has emerged as being completely acceptable for full replacement, various tests are considered to be suitable and are regularly used to assess certain aspects. Amongst these, the Hen's Egg Test Chorioallantoic Membrane (HET-CAM) has gained regulatory acceptance in various countries to classify severe eye irritants. In this retrospective study, historical eye irritation data (in vivo and in vitro) from 137 samples (approx. 75% non-irritants; 25% (severe) irritants) tested both in the HET-CAM and Draize eye test was compared with regard to the predicted eye irritation classes under the GHS and the traditional EU classification system (DSD).The overall concordance was in the range of 80-90%. A high specificity (96-98%, depending on the classification system and the chosen discrimination) but rather low sensitivity (48-65%) was observed. The study indicates that HET-CAM results are useful as part of weight-of-evidence assessments or in tiered approaches to assess eye irritation potentials rather than as stand-alone classification method.
Collapse
|
40
|
Sakaguchi H, Ota N, Omori T, Kuwahara H, Sozu T, Takagi Y, Takahashi Y, Tanigawa K, Nakanishi M, Nakamura T, Morimoto T, Wakuri S, Okamoto Y, Sakaguchi M, Hayashi T, Hanji T, Watanabe S. Validation study of the Short Time Exposure (STE) test to assess the eye irritation potential of chemicals. Toxicol In Vitro 2011; 25:796-809. [PMID: 21291995 DOI: 10.1016/j.tiv.2011.01.015] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2010] [Revised: 01/03/2011] [Accepted: 01/26/2011] [Indexed: 11/30/2022]
Abstract
Short time exposure (STE) test is a cytotoxicity test in SIRC cells (rabbit corneal cell line) that assesses eye irritation potential following a 5-min chemical exposure. This validation study assessed transferability, intra- and inter-laboratory reproducibility, and predictive capacity of STE test in five laboratories (supported by Japanese Society for Alternatives to Animal Experiments). Sodium lauryl sulfate, calcium thioglycolate, and Tween 80 were evaluated, in triplicate, using 5%, 0.5%, and 0.05% concentrations in physiological saline, to confirm transferability. Good transferability was noted when similar mean relative viabilities and rank classifications were obtained in all five laboratories and were comparable to data from test method developing laboratory. Good intra- and inter-laboratory reproducibility was obtained with four assay controls (three solvents and one positive control), and four assay controls and 25 chemicals, respectively. STE irritation category based on relative viability of a 5% solution of 25 blinded test chemicals showed good correlation with Globally Harmonized System (GHS) categories (NI; I: Cat. 1 and 2). The STE prediction model, using relative viability of the 5% and 0.05% solutions, provided an irritation rank (1, 2, or 3) that had a good correlation (above 80%), or predictive capacity, with GHS irritation ranks in all laboratories. Based on these findings, the STE test is a promising alternative eye irritation test that could be easily standardized.
Collapse
Affiliation(s)
- Hitoshi Sakaguchi
- Kao Corporation, Safety Science Research Laboratories, 2606 Akabane, Ichikai-Machi, Haga-Gun, Tochigi 321-3497, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Survey of ocular irritation predictive capacity using Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test historical data for 319 personal care products over fourteen years. Toxicol In Vitro 2010; 25:563-72. [PMID: 21147215 DOI: 10.1016/j.tiv.2010.12.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Revised: 11/29/2010] [Accepted: 12/02/2010] [Indexed: 11/21/2022]
Abstract
The Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test are widely used to predict ocular irritation potential for consumer-use products. These in vitro assays do not require live animals, produce reliable predictive data for defined applicability domains compared to the Draize rabbit eye test, and are rapid and inexpensive. Data from 304 CAMVA and/or BCOP studies (319 formulations) were surveyed to determine the feasibility of predicting ocular irritation potential for various formulations. Hair shampoos, skin cleansers, and ethanol-based hair styling sprays were repeatedly predicted to be ocular irritants (accuracy rate=0.90-1.00), with skin cleanser and hair shampoo irritation largely dependent on surfactant species and concentration. Conversely, skin lotions/moisturizers and hair styling gels/lotions were repeatedly predicted to be non-irritants (accuracy rate=0.92 and 0.82, respectively). For hair shampoos, ethanol-based hair stylers, skin cleansers, and skin lotions/moisturizers, future ocular irritation testing (i.e., CAMVA/BCOP) can be nearly eliminated if new formulations are systematically compared to those previously tested using a defined decision tree. For other tested product categories, new formulations should continue to be evaluated in CAMVA/BCOP for ocular irritation potential because either the historical data exhibit significant variability (hair conditioners and mousses) or the historical sample size is too small to permit definitive conclusions (deodorants, make-up removers, massage oils, facial masks, body sprays, and other hair styling products). All decision tree conclusions should be made within a conservative weight-of-evidence context, considering the reported limitations of the BCOP test for alcohols, ketones, and solids.
Collapse
|
42
|
Scheel J, Hermann M. Integrated risk assessment of a hydroxyapatite-protein-composite for use in oral care products: a weight-of-evidence case study. Regul Toxicol Pharmacol 2010; 59:310-23. [PMID: 21112362 DOI: 10.1016/j.yrtph.2010.11.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2010] [Revised: 11/04/2010] [Accepted: 11/22/2010] [Indexed: 11/26/2022]
Abstract
Risk assessment of cosmetic ingredients represents a regulatory standard requirement in Europe and other regions. An integrated approach was designed to assess the safety of HPC, a particulate composite of hydroxyapatite and protein (gelatin) for use in oral care products, employing a weight-of-evidence assessment and considering specific physico-chemical properties and exposure conditions. An initial evaluation of the constituents suggested that their chemical nature does not represent a particular health hazard per se. Hydroxyapatite is the main component of teeth and bones in mammals; gelatin is used in food and assumed to be safe once a BSE/TSE risk has been excluded. In vitro screening tests were chosen to further evaluate the biocompatibility: Hen's egg test-chorioallantoic membrane (HET-CAM) to assess irritating effects towards mucous membranes; MTT cytotoxicity test with 3T3 fibroblasts; human corneal epithelial models to investigate inflammatory mediators and cytotoxicity; macrophage assays to measure cytotoxicity, inflammatory mediators and oxidative stress. Together with results from clinical studies, exposure estimates and analyses of kinetic properties, the presented information provides sound evidence to support the safe use of HPC. This is an example of a risk assessment for cosmetic use of small particles without the need for additional animal studies.
Collapse
Affiliation(s)
- Julia Scheel
- Henkel AG & Co. KGaA, Corporate Product Safety, Department of Human Safety Assessment, Düsseldorf, Germany.
| | | |
Collapse
|
43
|
Development of a new opacitometer for the bovine corneal opacity and permeability (BCOP) assay. Toxicol In Vitro 2010; 24:1854-61. [DOI: 10.1016/j.tiv.2010.04.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2009] [Revised: 04/26/2010] [Accepted: 04/28/2010] [Indexed: 11/21/2022]
|
44
|
Takahashi Y, Hayashi T, Watanabe S, Hayashi K, Koike M, Aisawa N, Ebata S, Sakaguchi H, Nakamura T, Kuwahara H, Nishiyama N. Inter-laboratory study of short time exposure (STE) test for predicting eye irritation potential of chemicals and correspondence to globally harmonized system (GHS) classification. J Toxicol Sci 2010; 34:611-26. [PMID: 19952497 DOI: 10.2131/jts.34.611] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Short time exposure (STE) test using rabbit corneal cell line (SIRC) cells was developed as an alternative eye irritation test. STE test uses relative viability as the endpoint after cells are exposed to the test material at constant concentrations for 5 min. In this inter-laboratory study with 3 laboratories, 44 chemicals with a wide range of classes were evaluated for the transferability, between-lab reproducibility and predictive capacity of the STE test as an alternative eye irritation test. Globally harmonized system (GHS) classification based on Draize eye irritation test data was used as the comparative in vivo data. Transferability was assessed using standard chemicals (sodium lauryl sulfate, calcium thioglycolate, and Tween 80) and the coefficient variations (CVs) of relative viabilities between 3 labs were less than 0.13. The irritation category (Irritant or Non irritant) at each test concentration (5% and 0.05%) in STE test was the same in 3 laboratories for all 44 tested chemicals. The predictive capacity irritation category classification between STE test and GHS were compared, and a good correlation was confirmed (accuracy was 90.9% at all laboratories). In addition, the STE rankings of 1, 2, and 3 classified by the prediction model (PM) based on the relative viability at two concentrations (5% and 0.05%) were highly correlated with the GHS ranks of non-irritant, category 1, and category 2, respectively (accuracy was 75.0% at all laboratories). These results suggest that the STE test possessed easy transferability, reproducibility, good predictive performance.
Collapse
Affiliation(s)
- Yutaka Takahashi
- Safety Science Research Laboratories, Kao Corporation, Tochigi, Japan.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Jester JV, Ling J, Harbell J. Measuring depth of injury (DOI) in an isolated rabbit eye irritation test (IRE) using biomarkers of cell death and viability. Toxicol In Vitro 2010; 24:597-604. [DOI: 10.1016/j.tiv.2009.10.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2009] [Revised: 09/29/2009] [Accepted: 10/16/2009] [Indexed: 10/20/2022]
|
46
|
Barile FA. Validating and troubleshooting ocular in vitro toxicology tests. J Pharmacol Toxicol Methods 2010; 61:136-45. [PMID: 20096797 DOI: 10.1016/j.vascn.2010.01.001] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2009] [Revised: 01/12/2010] [Accepted: 01/14/2010] [Indexed: 11/25/2022]
Abstract
In vitro organotypic models for testing ocular irritants have warranted sufficient interest as methods to replace in vivo ocular testing. The in vitro organotypic models claim to maintain short-term normal physiological and biochemical functions of the mammalian cornea in an isolated system. In these test methods, damage by the test substance is assessed by quantitative measurements of changes in corneal opacity and permeability using opacitometry and spectrophotometry, respectively. Both measurements are used quantitatively for irritancy classification for prediction of the in vivo ocular irritation potential of a test substance. Examples of organotypic models that incorporate these criteria include: the bovine corneal opacity and permeability (BCOP) assay, the isolated chicken eye (ICE) test method and the isolated rabbit eye (IRE) assay. A fourth method, the hen's egg test-chorioallantoic membrane (HET-CAM) assay, differs in the evaluation criteria but is also normally included among this class of in vitro protocols. Each of these protocols is discussed in detail as representative candidate in vitro methods for assessing ocular irritation and corrosion. The methodologies, protocol details, applications, and their validation status are discussed. A brief historical perspective of the development of original in vitro ocular testing models is also mentioned. More importantly, improving and troubleshooting the current techniques, in order to present the models as stand-alone in vitro tools for ocular toxicity assessment, is emphasized.
Collapse
Affiliation(s)
- Frank A Barile
- Department of Pharmaceutical Sciences, Toxicology Division, St. John's University, College of Pharmacy and Allied Health Professions, Queens, New York 11439, USA.
| |
Collapse
|
47
|
Creton S, Dewhurst IC, Earl LK, Gehen SC, Guest RL, Hotchkiss JA, Indans I, Woolhiser MR, Billington R. Acute toxicity testing of chemicals—Opportunities to avoid redundant testing and use alternative approaches. Crit Rev Toxicol 2009; 40:50-83. [DOI: 10.3109/10408440903401511] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|