1
|
Tattan-Birch H, Hartmann-Boyce J, Kock L, Simonavicius E, Brose L, Jackson S, Shahab L, Brown J. Heated tobacco products for smoking cessation and reducing smoking prevalence. Cochrane Database Syst Rev 2022; 1:CD013790. [PMID: 34988969 PMCID: PMC8733777 DOI: 10.1002/14651858.cd013790.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND Heated tobacco products (HTPs) are designed to heat tobacco to a high enough temperature to release aerosol, without burning it or producing smoke. They differ from e-cigarettes because they heat tobacco leaf/sheet rather than a liquid. Companies who make HTPs claim they produce fewer harmful chemicals than conventional cigarettes. Some people report stopping smoking cigarettes entirely by switching to using HTPs, so clinicians need to know whether they are effective for this purpose and relatively safe. Also, to regulate HTPs appropriately, policymakers should understand their impact on health and on cigarette smoking prevalence. OBJECTIVES To evaluate the effectiveness and safety of HTPs for smoking cessation and the impact of HTPs on smoking prevalence. SEARCH METHODS: We searched the Cochrane Tobacco Addiction Group's Specialised Register, CENTRAL, MEDLINE, and six other databases for relevant records to January 2021, together with reference-checking and contact with study authors and relevant groups. SELECTION CRITERIA We included randomised controlled trials (RCTs) in which people who smoked cigarettes were randomised to switch to exclusive HTP use or a control condition. Eligible outcomes were smoking cessation, adverse events, and selected biomarkers. RCTs conducted in clinic or in an ambulatory setting were deemed eligible when assessing safety, including those randomising participants to exclusively use HTPs, smoke cigarettes, or attempt abstinence from all tobacco. Time-series studies were also eligible for inclusion if they examined the population-level impact of heated tobacco on smoking prevalence or cigarette sales as an indirect measure. DATA COLLECTION AND ANALYSIS We followed standard Cochrane methods for screening and data extraction. Our primary outcome measures were abstinence from smoking at the longest follow-up point available, adverse events, serious adverse events, and changes in smoking prevalence or cigarette sales. Other outcomes included biomarkers of harm and exposure to toxicants/carcinogens (e.g. NNAL and carboxyhaemoglobin (COHb)). We used a random-effects Mantel-Haenszel model to calculate risk ratios (RR) with 95% confidence intervals (CIs) for dichotomous outcomes. For continuous outcomes, we calculated mean differences on the log-transformed scale (LMD) with 95% CIs. We pooled data across studies using meta-analysis where possible. MAIN RESULTS We included 13 completed studies, of which 11 were RCTs assessing safety (2666 participants) and two were time-series studies. We judged eight RCTs to be at unclear risk of bias and three at high risk. All RCTs were funded by tobacco companies. Median length of follow-up was 13 weeks. No studies reported smoking cessation outcomes. There was insufficient evidence for a difference in risk of adverse events between smokers randomised to switch to heated tobacco or continue smoking cigarettes, limited by imprecision and risk of bias (RR 1.03, 95% CI 0.92 to 1.15; I2 = 0%; 6 studies, 1713 participants). There was insufficient evidence to determine whether risk of serious adverse events differed between groups due to very serious imprecision and risk of bias (RR 0.79, 95% CI 0.33 to 1.94; I2 = 0%; 4 studies, 1472 participants). There was moderate-certainty evidence for lower NNAL and COHb at follow-up in heated tobacco than cigarette smoking groups, limited by risk of bias (NNAL: LMD -0.81, 95% CI -1.07 to -0.55; I2 = 92%; 10 studies, 1959 participants; COHb: LMD -0.74, 95% CI -0.92 to -0.52; I2 = 96%; 9 studies, 1807 participants). Evidence for additional biomarkers of exposure are reported in the main body of the review. There was insufficient evidence for a difference in risk of adverse events in smokers randomised to switch to heated tobacco or attempt abstinence from all tobacco, limited by risk of bias and imprecision (RR 1.12, 95% CI 0.86 to 1.46; I2 = 0%; 2 studies, 237 participants). Five studies reported that no serious adverse events occurred in either group (533 participants). There was moderate-certainty evidence, limited by risk of bias, that urine concentrations of NNAL at follow-up were higher in the heated tobacco use compared with abstinence group (LMD 0.50, 95% CI 0.34 to 0.66; I2 = 0%; 5 studies, 382 participants). In addition, there was very low-certainty evidence, limited by risk of bias, inconsistency, and imprecision, for higher COHb in the heated tobacco use compared with abstinence group for intention-to-treat analyses (LMD 0.69, 95% CI 0.07 to 1.31; 3 studies, 212 participants), but lower COHb in per-protocol analyses (LMD -0.32, 95% CI -1.04 to 0.39; 2 studies, 170 participants). Evidence concerning additional biomarkers is reported in the main body of the review. Data from two time-series studies showed that the rate of decline in cigarette sales accelerated following the introduction of heated tobacco to market in Japan. This evidence was of very low-certainty as there was risk of bias, including possible confounding, and cigarette sales are an indirect measure of smoking prevalence. AUTHORS' CONCLUSIONS No studies reported on cigarette smoking cessation, so the effectiveness of heated tobacco for this purpose remains uncertain. There was insufficient evidence for differences in risk of adverse or serious adverse events between people randomised to switch to heated tobacco, smoke cigarettes, or attempt tobacco abstinence in the short-term. There was moderate-certainty evidence that heated tobacco users have lower exposure to toxicants/carcinogens than cigarette smokers and very low- to moderate-certainty evidence of higher exposure than those attempting abstinence from all tobacco. Independently funded research on the effectiveness and safety of HTPs is needed. The rate of decline in cigarette sales accelerated after the introduction of heated tobacco to market in Japan but, as data were observational, it is possible other factors caused these changes. Moreover, falls in cigarette sales may not translate to declining smoking prevalence, and changes in Japan may not generalise elsewhere. To clarify the impact of rising heated tobacco use on smoking prevalence, there is a need for time-series studies that examine this association.
Collapse
Affiliation(s)
- Harry Tattan-Birch
- Department of Behavioural Science and Health, University College London, London, UK
| | - Jamie Hartmann-Boyce
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Loren Kock
- Department of Behavioural Science and Health, University College London, London, UK
| | - Erikas Simonavicius
- Department of Addictions, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Leonie Brose
- Department of Addictions, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Sarah Jackson
- Department of Behavioural Science and Health, University College London, London, UK
| | - Lion Shahab
- Department of Behavioural Science and Health, University College London, London, UK
| | - Jamie Brown
- Department of Behavioural Science and Health, University College London, London, UK
| |
Collapse
|
2
|
Akiyama Y, Sherwood N. Systematic review of biomarker findings from clinical studies of electronic cigarettes and heated tobacco products. Toxicol Rep 2021; 8:282-294. [PMID: 33552927 PMCID: PMC7850959 DOI: 10.1016/j.toxrep.2021.01.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/21/2021] [Accepted: 01/21/2021] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Worldwide adoption of electronic cigarettes (e-cigarettes) and heated tobacco products (HTPs) has increased exponentially over the past decade. These products have been proposed as non-combustible alternatives to traditional tobacco products such as cigarettes and may thus reduce the negative health consequences associated with tobacco smoke. However, the overall health impact and safety of using these products remains unclear. This review seeks to provide an updated summary of available evidence on changes to levels of tobacco-related biomarkers to aid the overall assessment of the consequences of using e-cigarettes and HTPs. METHODS A systematic review was conducted through major databases (Medline/PubMed, Scopus, EMBASE) searching for articles directly comparing biomarker levels in humans using e-cigarettes or HTPs and those using combustible cigarettes. We included peer reviewed articles with comparative or longitudinal design and extracted key information for our purpose (type of population, demographics, biomarkers measurements, and health effects). An initial qualitative analysis was performed followed by a summary of findings. RESULTS A total of 44 studies were included from initial citations. The vast majority of the literature reported reductions in levels of biomarkers of tobacco smoke exposure (BOE), especially nicotine, MHBMA, 3-HPMA, S-PMA, 1-OHP and NNAL, when using e-cigarettes and HTPs compared to combustible cigarettes. There was a slight tendency toward a larger reduction in these biomarkers levels with the use of e-cigarettes, although direct comparisons between e-cigarettes and HTPs were lacking. There was also a trend toward positive changes in levels of biomarkers of biological effect (BOBE) with the use of e-cigarettes and HTPs. CONCLUSIONS A comparison of levels of biomarkers of tobacco-related exposure collected in clinical studies revealed that the use of e-cigarettes and HTPs could lead to a significant reduction in exposure to harmful substances compared to combusted cigarettes. In tandem, the health status of e-cigarettes and HTP users, indexed by levels of biomarkers of biological effect showed potential for improvement compared to smoking. However, larger and longer-term population-based studies are needed to further clarify these findings.
Collapse
Key Words
- BAT, British American Tobacco
- BOBE, biomarkers of biological effect
- BOE, biomarkers of tobacco smoke exposure
- Biomarkers of biological effect (BOBE)
- Biomarkers of tobacco smoke exposure (BOE)
- CHTP, Carbon-Heated Tobacco Product
- Clinical study
- E-cigarettes, electronic cigarettes
- EHCSS, Electrically Heated Cigarette Smoking System
- EVPs, electronic vapor products
- Electronic cigarette
- FV, Fontem Ventures
- HC, heated cigarette
- HTPs, heated tobacco products
- Heated tobacco products
- JT, Japan Tobacco
- NOS scale, The Newcastle-Ottawa Scale
- NSPS, nicotine-salt pod system
- NTV, Novel Tobacco vapor products
- PMI, Philip Morris International
- PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses
- RAI, Reynolds American Inc
- RCT, randomized controlled trial
- RJR, R.J. Reynolds Tobacco Company
- RJRVC, R.J. Reynolds Vapor Company
- RTP, reduced-toxicant-prototype cigarette
- THP, tobacco heating product
- THS, Tobacco Heating System
- UCS, Uncontrolled smoking conditions
- WHO, World Health Organization
- mTHS, Menthol Tobacco Heating System
Collapse
Affiliation(s)
- Yukio Akiyama
- Department of Environmental Management, University of Occupational and Environmental Health, Kitakyushu, Japan
| | | |
Collapse
|
3
|
Haziza C, de La Bourdonnaye G, Donelli A, Skiada D, Poux V, Weitkunat R, Baker G, Picavet P, Lüdicke F. Favorable Changes in Biomarkers of Potential Harm to Reduce the Adverse Health Effects of Smoking in Smokers Switching to the Menthol Tobacco Heating System 2.2 for 3 Months (Part 2). Nicotine Tob Res 2020; 22:549-559. [PMID: 31125079 PMCID: PMC7164580 DOI: 10.1093/ntr/ntz084] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 05/23/2019] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Tobacco Heating System (THS) 2.2, a candidate modified-risk tobacco product, aims at offering an alternative to cigarettes for smokers while substantially reducing the exposure to harmful and potentially harmful constituents found in cigarette smoke. METHODS One hundred and sixty healthy adult US smokers participated in this randomized, three-arm parallel group, controlled clinical study. Subjects were randomized in a 2:1:1 ratio to menthol Tobacco Heating System 2.2 (mTHS), menthol cigarette, or smoking abstinence for 5 days in confinement and 86 subsequent ambulatory days. Endpoints included biomarkers of exposure to harmful and potentially harmful constituents (reported in our co-publication, Part 1) and biomarkers of potential harm (BOPH). RESULTS Compliance (protocol and allocated product exposure) was 51% and 18% in the mTHS and smoking abstinence arms, respectively, on day 90. Nonetheless, favorable changes in BOPHs of lipid metabolism (total cholesterol and high- and low-density cholesterol), endothelial dysfunction (soluble intercellular adhesion molecule-1), oxidative stress (8-epi-prostaglandin F2α), and cardiovascular risk factors (eg, high-sensitivity C-reactive protein) were observed in the mTHS group. Favorable effects in other BOPHs, including ones related to platelet activation (11-dehydrothromboxane B2) and metabolic syndrome (glucose), were more pronounced in normal weight subjects. CONCLUSIONS The results suggest that the reduced exposure demonstrated when switching to mTHS is associated with overall improvements in BOPHs, which are indicative of pathomechanistic pathways underlying the development of smoking-related diseases, with some stronger effects in normal weight subjects. IMPLICATIONS Switching to mTHS was associated with favorable changes for some BOPHs indicative of biological pathway alterations (eg, oxidative stress and endothelial dysfunction). The results suggest that switching to mTHS has the potential to reduce the adverse health effects of smoking and ultimately the risk of smoking-related diseases. Switching to mTHS for 90 days led to reductions in a number of biomarkers of exposure in smokers, relative to those who continued smoking cigarettes, which were close to those observed when stopping smoking (reported in our co-publication, Part 1). Initial findings suggest reduced levels of 8-epi-prostaglandin F2α and intercellular adhesion molecule 1, when switching to mTHS for 90 days. These changes are comparable to what is observed upon smoking cessation. In normal weight subjects, additional favorable changes were seen in 11-dehydrothromboxane B2, fibrinogen, homocysteine, hs-CRP, percentage of predicted forced expiratory volume in 1 second, systolic blood pressure, diastolic blood pressure, glucose, high-density lipoprotein, apolipoprotein A1, and triglycerides. TRIAL REGISTRATION NCT01989156.
Collapse
Affiliation(s)
- Christelle Haziza
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | | | - Andrea Donelli
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Dimitra Skiada
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Valerie Poux
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Rolf Weitkunat
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Gizelle Baker
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Patrick Picavet
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Frank Lüdicke
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
4
|
Obertova N, Navratil T, Zak I, Zakharov S. Acute exposures to e-cigarettes and heat-not-burn products reported to the Czech Toxicological Information Centre over a 7-year period (2012-2018). Basic Clin Pharmacol Toxicol 2020; 127:39-46. [PMID: 32012431 DOI: 10.1111/bcpt.13393] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 01/13/2020] [Accepted: 01/19/2020] [Indexed: 11/29/2022]
Abstract
E-cigarettes and heat-not-burn cigarettes (HNBC) present new health risks due to their rising popularity, high content of nicotine and serious adverse effects. The objective of the study was to analyse the cases of acute exposure to e-cigarettes, e-liquids and HNBC products containing nicotine that led to toxicological consultations at our poisons control centre during a 7-year period (2012-2018) and identify the categories of special concern that require further investigation and intervention. The demographic, toxicological and clinical data were analysed by descriptive statistics. Poisoning severity score (PSS) was estimated. From 119 229 consultations, 148 cases concerned acute exposure to e-cigarettes. Children and adolescents were exposed in 91 (61%) cases, including exposure of neonates and infants in 54 (36%) cases. The main route of exposure was ingestion in 129 (87%), inhalation in nine (6%), ocular in six (4%) and intravenous administration in three (2%) cases. The source of exposure was the cartridge with e-liquid (107; 72%), refillable tank in 29 (20%) and HNBC refill in nine (6%) cases. The reason for exposure was accidental in 110 (74%), incorrect application of the device in 10 (7%), abuse in six (4%), suicide attempt in six (4%) and other/unknown in 16 (11%) cases. The dose estimation was severe/lethal in 6 (4%), toxic in 53 (36%), low-to-moderate in 35 (24%) and unknown in 54 (36%) cases. Vomiting was observed in 38 (26%) patients; 72% of patients were hospitalised. In symptomatic cases, 41 patient had PSS 1, 12 patients had PSS 2, and one patient had PSS 3. Activated charcoal was applied in 57 (39%) patients, and symptomatic treatment was recommended in 75 (51%) patients. Cases of unintentional exposure of children demonstrate the need for preventive risk reduction measures.
Collapse
Affiliation(s)
- Nikola Obertova
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Tomas Navratil
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Electrochemistry at the Nanoscale, J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, Czech Republic
| | - Ivan Zak
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Sergey Zakharov
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| |
Collapse
|
5
|
Lüdicke F, Picavet P, Baker G, Haziza C, Poux V, Lama N, Weitkunat R. Effects of Switching to the Tobacco Heating System 2.2 Menthol, Smoking Abstinence, or Continued Cigarette Smoking on Biomarkers of Exposure: A Randomized, Controlled, Open-Label, Multicenter Study in Sequential Confinement and Ambulatory Settings (Part 1). Nicotine Tob Res 2019; 20:161-172. [PMID: 28177489 PMCID: PMC5896533 DOI: 10.1093/ntr/ntw287] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 10/25/2016] [Indexed: 12/02/2022]
Abstract
Introduction The menthol Tobacco Heating System 2.2 (mTHS) is a newly developed candidate modified-risk tobacco product intended to reduce exposure to the harmful and potentially harmful constituents (HPHCs) of conventional cigarette (CC) smoke. This study examined the impact of switching to mTHS on biomarkers of exposure to HPHCs relative to menthol CCs (mCCs) and smoking abstinence (SA). Methods In this three-arm, parallel-group study, 160 Japanese adult smokers (23–65 years; smoking ≥10 mCCs per day) were randomized to mTHS (n = 78), mCC (n = 42), or SA (n = 40) for 5 days in confinement and 85 days in ambulatory settings. Endpoints included biomarkers of exposure to HPHCs, human puffing topography, safety, and subjective effects of smoking measures. Results After 5 days of product use, the concentrations of carboxyhemoglobin, 3-hydroxypropylmercapturic acid, monohydroxybutenyl mercapturic acid, and S-phenylmercapturic acid were 55%, 49%, 87%, and 89% lower (p < .001), respectively, in the mTHS group than in the mCC group. Other biomarkers of exposure (measured as secondary endpoints) were 50%–94% lower in the mTHS group than in the mCC group on day 5. These reductions in the mTHS group were maintained at day 90, similar to the SA group. Switching to mTHS was associated with changes in human puffing topography (shorter puff intervals and more frequent puffs). The urge-to-smoke and smoking satisfaction levels on day 90 were similar in the mTHS and the mCC groups. Conclusion Switching from mCCs to mTHS significantly reduced exposure to HPHCs relative to continuing smoking mCCs with concentrations similar to those observed following SA in Japanese adult smokers. Implications This randomized study compared the impact of switching to a modified-risk tobacco product candidate mTHS on biomarkers of exposure to HPHCs of cigarette smoke relative to continuing smoking cigarettes or abstaining from smoking in sequential confinement and ambulatory settings. The study showed that switching to mTHS was associated with significant biomarker reductions within 5 days in confinement, these reductions being maintained throughout the ambulatory setting up to day 90. The results provide evidence that switching to mTHS reduces real-life exposure to HPHCs in adult smokers.
Collapse
Affiliation(s)
- Frank Lüdicke
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Patrick Picavet
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Gizelle Baker
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Christelle Haziza
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Valerie Poux
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Nicola Lama
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| |
Collapse
|
6
|
Dautzenberg B, Dautzenberg MD. [Systematic analysis of the scientific literature on heated tobacco]. Rev Mal Respir 2019; 36:82-103. [PMID: 30429092 DOI: 10.1016/j.rmr.2018.10.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 10/26/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION The tobacco industry (TI) reports that heated tobacco reduces risk of tobacco use and will replace cigarettes. An analysis of the scientific literature was conducted in order to enlighten professionals and decision-makers. METHOD After a Medline query in February 2018, a systematic analysis was conducted. RESULTS Of the 100 papers published in 2008-2018, 75 have authors affiliated or linked to TI. Emissions contain gases, droplets and solid particles, so are smokes. The main products are: THS2.2 (Iqos®) which heats mini-cigarettes at 340°C, the THP1.0 (Glo®) which heats at 240°C sticks delivering about half as much nicotine, Ploom® which uses reconstituted tobacco microcapsules heated at 180°C. Under the experimental conditions, there is a reduction of toxic emissions and biological effects, but the expected risk reduction is not demonstrated. Symptoms related to passive smoking are described. The 4 epidemiological articles report that heated tobacco is used in 10 to 45% of cases by non-smokers and demonstrate the effectiveness of TI promotion campaigns. Thus, the THS2.2 is more a gateway to smoking (20%) than an exit door (11%); moreover, it is not expected risk reduction among the 69% who are mixed users. CONCLUSIONS While reducing emissions is documented, reducing the risk to the smoker who switches to heated-tobacco remains to be demonstrated. On the other hand, the worsening of the global tobacco risk related to the promotion of the products by the TI is anticipated, justifying that the authorities take the appropriate measures to control the promotion of heated tobacco.
Collapse
Affiliation(s)
- B Dautzenberg
- Service de pharmacologie, Pitié-Salpêtrière, AP-HP, 75013 Paris, France; Consultation de médecine, hôpital Marmottan, 75017 Paris, France; Consultation de tabacologie, institut Arthur-Vernes, 75006 Paris, France; Paris sans tabac, 14, avenue Bosquet, 75007 Paris, France.
| | | |
Collapse
|
7
|
Nabavizadeh P, Liu J, Havel CM, Ibrahim S, Derakhshandeh R, Jacob Iii P, Springer ML. Vascular endothelial function is impaired by aerosol from a single IQOS HeatStick to the same extent as by cigarette smoke. Tob Control 2018; 27:s13-s19. [PMID: 30206183 PMCID: PMC6202192 DOI: 10.1136/tobaccocontrol-2018-054325] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 05/10/2018] [Accepted: 05/11/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Heated tobacco products (also called 'heat-not-burn' products) heat tobacco at temperatures below that of combustion, causing nicotine and other compounds to aerosolise. One such product, IQOS from Philip Morris International, is being marketed internationally with claims of harm reduction. We sought to determine whether exposure to IQOS aerosol impairs arterial flow-mediated dilation (FMD), a measure of vascular endothelial function that is impaired by tobacco smoke. METHODS We exposed anaesthetised rats (n=8/group) via nose cone to IQOS aerosol from single HeatSticks, mainstream smoke from single Marlboro Red cigarettes or clean air for a series of consecutive 30 s cycles over 1.5-5 min. Each cycle consisted of 15 or 5 s of exposure followed by removal from the nose cone. We measured pre-exposure and postexposure FMD, and postexposure serum nicotine and cotinine. RESULTS FMD was impaired comparably by ten 15 s exposures and ten 5 s exposures to IQOS aerosol and to cigarette smoke, but not by clean air. Serum nicotine levels were similar to plasma levels after humans have smoked one cigarette, confirming that exposure conditions had real-world relevance. Postexposure nicotine levels were ~4.5-fold higher in rats exposed to IQOS than to cigarettes, despite nicotine being measured in the IQOS aerosol at ~63% the amount measured in smoke. When IQOS exposure was briefer, leading to comparable serum nicotine levels to the cigarette group, FMD was still comparably impaired. CONCLUSIONS Acute exposures to IQOS aerosol impairs FMD in rats. IQOS use does not necessarily avoid the adverse cardiovascular effects of smoking cigarettes.
Collapse
Affiliation(s)
- Pooneh Nabavizadeh
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Jiangtao Liu
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Christopher M Havel
- Division of Clinical Pharmacology and Experimental Therapeutics, University of California, San Francisco, San Francisco, California, USA
| | - Sharina Ibrahim
- Division of Cardiology, University of California, San Francisco, San Francisco, California, USA
| | - Ronak Derakhshandeh
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Peyton Jacob Iii
- Division of Clinical Pharmacology and Experimental Therapeutics, University of California, San Francisco, San Francisco, California, USA
- Center for Tobacco Control Research and Education, University of California, San Francisco, San Francisco, California, USA
| | - Matthew L Springer
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
- Division of Cardiology, University of California, San Francisco, San Francisco, California, USA
- Center for Tobacco Control Research and Education, University of California, San Francisco, San Francisco, California, USA
| |
Collapse
|
8
|
Caponnetto P, Maglia M, Prosperini G, Busà B, Polosa R. Carbon monoxide levels after inhalation from new generation heated tobacco products. Respir Res 2018; 19:164. [PMID: 30170593 PMCID: PMC6119326 DOI: 10.1186/s12931-018-0867-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/20/2018] [Indexed: 01/20/2023] Open
Abstract
Heated tobacco products (HTPs) are new tech devices that release nicotine and other volatile compounds into an inhalable aerosol by heating the tobacco. At their operating temperatures, tobacco combustion is unlikely. The aim of this randomized cross-over study was to measure the exposure levels of the combustion marker, carbon monoxide in the exhaled breath (eCO) of subjects after use of two HTPs and to compare these levels with participants’ own brand of cigarettes. A total of 12 healthy smokers who reported smoking ≥10 conventional cigarettes per day for at least 5 years took part in the study. Product administration consisted of a first round of 10 puffs, which was followed by an identical second round after a 5 min pause in between rounds. After obtaining a baseline eCO value, this measure was recorded at 5, 10, 15, 30, and 45 min after the first puff of the first round. In contrast to combustible cigarettes, no eCO elevations were observed in the exhaled breath after use of the HTPs under investigation in any of the study participants.
Collapse
Affiliation(s)
- Pasquale Caponnetto
- Centro per la Prevenzione e Cura del Tabagismo (CPCT), Azienda Ospedaliero-Universitaria "Policlinico-V. Emanuele", Università di Catania, Catania, Italy.,Dipartimento di Medicina Clinica e Sperimentale, Università di Catania, Catania, Italy
| | - Marilena Maglia
- Centro per la Prevenzione e Cura del Tabagismo (CPCT), Azienda Ospedaliero-Universitaria "Policlinico-V. Emanuele", Università di Catania, Catania, Italy.,Dipartimento di Medicina Clinica e Sperimentale, Università di Catania, Catania, Italy
| | | | - Barbara Busà
- UOC Farmacia Ospedaliera, ARNAS Garibaldi, Catania, Italy
| | - Riccardo Polosa
- Centro per la Prevenzione e Cura del Tabagismo (CPCT), Azienda Ospedaliero-Universitaria "Policlinico-V. Emanuele", Università di Catania, Catania, Italy. .,Dipartimento di Medicina Clinica e Sperimentale, Università di Catania, Catania, Italy. .,Center of Excellence for the Acceleration of Harm Reduction (CoEHAR), Università di Catania, Catania, Italy. .,UOC di Medicina Interna e d'Urgenza, Edificio 4, Piano 3, AOU "Policlinico-V. Emanuele", Via S. Sofia 78, 95123, Catania, Italy.
| |
Collapse
|
9
|
Martin F, Vuillaume G, Baker G, Sponsiello-Wang Z, Ricci PF, Lüdicke F, Weitkunat R. Quantifying the risk-reduction potential of new Modified Risk Tobacco Products. Regul Toxicol Pharmacol 2018; 92:358-369. [PMID: 29258927 DOI: 10.1016/j.yrtph.2017.12.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 12/04/2017] [Accepted: 12/15/2017] [Indexed: 12/31/2022]
Abstract
Quantitative risk assessment of novel Modified Risk Tobacco Products (MRTP) must rest on indirect measurements that are indicative of disease development prior to epidemiological data becoming available. For this purpose, a Population Health Impact Model (PHIM) has been developed to estimate the reduction in the number of deaths from smoking-related diseases following the introduction of an MRTP. One key parameter of the model, the F-factor, describes the effective dose upon switching from cigarette smoking to using an MRTP. Biomarker data, collected in clinical studies, can be analyzed to estimate the effects of switching to an MRTP as compared to quitting smoking. Based on transparent assumptions, a link function is formulated that translates these effects into the F-factor. The concepts of 'lack of sufficiency' and 'necessity' are introduced, allowing for a parametrization of a family of link functions. These can be uniformly sampled, thus providing different 'scenarios' on how biomarker-based evidence can be translated into the F-factor to inform the PHIM.
Collapse
Affiliation(s)
- Florian Martin
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Gregory Vuillaume
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Gizelle Baker
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | | | | | - Frank Lüdicke
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Philip Morris International Research & Development, Neuchâtel, Switzerland.
| |
Collapse
|
10
|
Peck MJ, Sanders EB, Scherer G, Lüdicke F, Weitkunat R. Review of biomarkers to assess the effects of switching from cigarettes to modified risk tobacco products. Biomarkers 2018; 23:213-244. [PMID: 29297706 DOI: 10.1080/1354750x.2017.1419284] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Context: One approach to reducing the harm caused by cigarette smoking, at both individual and population level, is to develop, assess and commercialize modified risk alternatives that adult smokers can switch to. Studies to demonstrate the exposure and risk reduction potential of such products generally involve the measuring of biomarkers, of both exposure and effect, sampled in various biological matrices.Objective: In this review, we detail the pros and cons for using several biomarkers as indicators of effects of changing from conventional cigarettes to modified risk products.Materials and methods: English language publications between 2008 and 2017 were retrieved from PubMed using the same search criteria for each of the 25 assessed biomarkers. Nine exclusion criteria were applied to exclude non-relevant publications.Results: A total of 8876 articles were retrieved (of which 7476 were excluded according to the exclusion criteria). The literature indicates that not all assessed biomarkers return to baseline levels following smoking cessation during the study periods but that nine had potential for use in medium to long-term studies.Discussion and conclusion: In clinical studies, it is important to choose biomarkers that show the biological effect of cessation within the duration of the study.
Collapse
Affiliation(s)
| | | | | | - Frank Lüdicke
- Research & Development, Philip Morris International, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Research & Development, Philip Morris International, Neuchâtel, Switzerland
| |
Collapse
|
11
|
Gale N, McEwan M, Eldridge AC, Sherwood N, Bowen E, McDermott S, Holmes E, Hedge A, Hossack S, Camacho OM, Errington G, McAughey J, Murphy J, Liu C, Proctor CJ, Fearon IM. A randomised, controlled, two-Centre open-label study in healthy Japanese subjects to evaluate the effect on biomarkers of exposure of switching from a conventional cigarette to a tobacco heating product. BMC Public Health 2017; 17:673. [PMID: 28830420 PMCID: PMC5567437 DOI: 10.1186/s12889-017-4678-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 08/10/2017] [Indexed: 01/16/2023] Open
Abstract
Background Smoking is a leading cause of numerous human disorders including lung cancer, chronic obstructive pulmonary disease, and atherosclerotic cardiovascular disease. The development of modified risk tobacco products (MRTPs) has been suggested as a possible way to reduce the risks of tobacco smoking by reducing exposure to cigarette smoke toxicants. This study is designed to investigate whether biomarkers of such exposure are reduced when smokers switch from smoking commercial cigarettes to using either a novel or a commercially-available tobacco heating product (THP). Design and Methods This study will assess biomarkers of exposure in current smokers who either remain smoking, switch to THP use, or quit all tobacco use completely, for 5 days. The study is an in-clinic (confinement) two-centre, randomised controlled clinical study with a forced-switching design. Subjects of either gender will be aged 23–55 years (minimum legal smoking age plus 3 years), of Japanese origin and with a verified smoking status (assessed by exhaled breath carbon monoxide and urinary cotinine levels). Subjects will have a usual brand cigarette within the International Organisation for Standardisation (ISO) tar band of 6-8 mg and will be judged to be healthy by medical history, physical examination, vital signs, electrocardiography (ECG), clinical biochemistry and lung function tests. The primary objective of this study is to assess changes within groups in selected biomarkers of exposure (BoE) and of biological effect (BoBE) after a forced switch from a commercial control cigarette to either a menthol or a non-menthol THP. Secondary objectives are to assess between-group differences, to determine nicotine pharmacokinetics for cigarettes and THPs, to assess subject’s satisfaction with the study products, and to monitor additional endpoints related to safety and product use. Discussion Data from this study will advance our scientific understanding of the changes in exposure to cigarette smoke toxicants in smokers who switch to using a THP. Trial registrations UMIN000024988 (25th November 2016); ISRCTN14301360 (14th December 2016) Electronic supplementary material The online version of this article (doi:10.1186/s12889-017-4678-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Nathan Gale
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Mike McEwan
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Alison C Eldridge
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Neil Sherwood
- Neil Sherwood Consulting, 22 Route de Marnex, CH-1291, Commugny, Switzerland
| | - Edward Bowen
- Early Clinical Services Medical Writing, Global Medical and Regulatory Writing, Covance Clinical Research Unit Limited, Springfield House, Hyde Street, Leeds, LS2 9LH, UK
| | - Simon McDermott
- Early Clinical Development, Covance Clinical and Periapproval Services Limited, Ground Floor, Apsley House, 78 Wellington St, Leeds, LS1 2EQ, UK
| | - Emma Holmes
- Early Clinical Development, Covance Clinical and Periapproval Services Limited, Ground Floor, Apsley House, 78 Wellington St, Leeds, LS1 2EQ, UK
| | - Andrew Hedge
- Early Clinical Development, Covance Clinical and Periapproval Services Limited, Ground Floor, Apsley House, 78 Wellington St, Leeds, LS1 2EQ, UK
| | - Stuart Hossack
- Early Clinical Development, Covance Clinical and Periapproval Services Limited, Ground Floor, Apsley House, 78 Wellington St, Leeds, LS1 2EQ, UK
| | - Oscar M Camacho
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Graham Errington
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - John McAughey
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - James Murphy
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Chuan Liu
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Christopher J Proctor
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | - Ian M Fearon
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK.
| |
Collapse
|
12
|
Evaluation of the Tobacco Heating System 2.2. Part 1: Description of the system and the scientific assessment program. Regul Toxicol Pharmacol 2016; 81 Suppl 2:S17-S26. [DOI: 10.1016/j.yrtph.2016.07.006] [Citation(s) in RCA: 169] [Impact Index Per Article: 21.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 07/08/2016] [Indexed: 11/19/2022]
|
13
|
Lüdicke F, Haziza C, Weitkunat R, Magnette J. Evaluation of Biomarkers of Exposure in Smokers Switching to a Carbon-Heated Tobacco Product: A Controlled, Randomized, Open-Label 5-Day Exposure Study. Nicotine Tob Res 2016; 18:1606-13. [PMID: 26817490 PMCID: PMC4902889 DOI: 10.1093/ntr/ntw022] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Accepted: 01/16/2016] [Indexed: 01/05/2023]
Abstract
Introduction: Tobacco harm reduction aims to provide reduced risk alternatives to adult smokers who would otherwise continue smoking combustible cigarettes (CCs). This randomized, open-label, three-arm, parallel-group, single-center, short-term confinement study aimed to investigate the effects of exposure to selected harmful and potentially harmful constituents (HPHCs) of cigarette smoke in adult smokers who switched to a carbon-heated tobacco product (CHTP) compared with adult smokers who continued to smoke CCs and those who abstained from smoking for 5 days. Methods: Biomarkers of exposure to HPHCs, including nicotine and urinary excretion of mutagenic material, were measured in 24-hour urine and blood samples in 112 male and female Caucasian smokers switching from CCs to the CHTP ad libitum use. Puffing topography was assessed during product use. Results: Switching to the CHTP or smoking abstinence (SA) resulted in marked decreases from baseline to Day 5 in all biomarkers of exposure measured, including carboxyhemoglobin (43% and 55% decrease in the CHTP and SA groups, respectively). The urinary excretion of mutagenic material was also markedly decreased on Day 5 compared with baseline (89% and 87% decrease in the CHTP and SA groups, respectively). No changes in biomarkers of exposure to HPHCs or urinary mutagenic material were observed between baseline and Day 5 in the CC group. Conclusions: Our results provide clear evidence supporting a reduction in the level of exposure to HPHCs of tobacco smoke in smokers who switch to CHTP under controlled conditions, similar to that observed in SA. Implications: The reductions observed in biomarkers of exposure to HPHCs of tobacco smoke in this short-term study could potentially also reduce the incidence of cancer, cardiovascular and respiratory diseases in those smokers who switch to a heated tobacco product.
Collapse
Affiliation(s)
- Frank Lüdicke
- Department of Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Christelle Haziza
- Department of Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Department of Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - John Magnette
- Department of Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
14
|
Pisinger C, Døssing M. A systematic review of health effects of electronic cigarettes. Prev Med 2014; 69:248-60. [PMID: 25456810 DOI: 10.1016/j.ypmed.2014.10.009] [Citation(s) in RCA: 322] [Impact Index Per Article: 32.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Revised: 09/19/2014] [Accepted: 10/09/2014] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To provide a systematic review of the existing literature on health consequences of vaporing of electronic cigarettes (ECs). METHODS Search in: PubMed, EMBASE and CINAHL. INCLUSION CRITERIA Original publications describing a health-related topic, published before 14 August 2014. PRISMA recommendations were followed. We identified 1101 studies; 271 relevant after screening; 94 eligible. RESULTS We included 76 studies investigating content of fluid/vapor of ECs, reports on adverse events and human and animal experimental studies. Serious methodological problems were identified. In 34% of the articles the authors had a conflict of interest. Studies found fine/ultrafine particles, harmful metals, carcinogenic tobacco-specific nitrosamines, volatile organic compounds, carcinogenic carbonyls (some in high but most in low/trace concentrations), cytotoxicity and changed gene expression. Of special concern are compounds not found in conventional cigarettes, e.g. propylene glycol. Experimental studies found increased airway resistance after short-term exposure. Reports on short-term adverse events were often flawed by selection bias. CONCLUSIONS Due to many methodological problems, severe conflicts of interest, the relatively few and often small studies, the inconsistencies and contradictions in results, and the lack of long-term follow-up no firm conclusions can be drawn on the safety of ECs. However, they can hardly be considered harmless.
Collapse
Affiliation(s)
- Charlotta Pisinger
- Research Centre for Prevention and Health, Glostrup Hospital, DK-2600 Glostrup, Denmark.
| | - Martin Døssing
- Medicinsk Afdeling, Frederikssund Hospital, DK-3600 Frederikssund, Denmark
| |
Collapse
|
15
|
Martin Leroy C, Jarus-Dziedzic K, Ancerewicz J, Lindner D, Kulesza A, Magnette J. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 7: A one-month, randomized, ambulatory, controlled clinical study in Poland. Regul Toxicol Pharmacol 2012; 64:S74-84. [PMID: 22951349 DOI: 10.1016/j.yrtph.2012.08.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/01/2023]
Abstract
This randomized, open-label, ambulatory, controlled clinical study investigated biomarkers associated with cardiovascular risk and biomarkers of exposure to 10 selected harmful and potentially harmful constituents (HPHC) in cigarette smoke in 316 male and female Polish smokers. Subjects were randomized to continue smoking conventional cigarettes (CC; N=79) or switch to smoking the Electrically Heated Cigarette Smoking System series-K cigarette (EHCSS-K6; N=237). Biomarker assessments were performed at several time points during the study at baseline and during the 1-month investigational period. The primary biomarkers were high-sensitivity C-reactive protein and white blood cell counts. No statistically significant differences in the two primary biomarkers were found between the study groups at the end of the study. End-of-study comparisons of secondary biomarkers between study groups indicated an increase in high-density lipoprotein cholesterol, and reductions in red blood cell count, hemoglobin, and hematocrit levels in the EHCSS-K6 group. All biomarkers of exposure to cigarette smoke HPHC were decreased in the EHCSS-K6 group, despite an increase in cigarette consumption, compared to the CC group. There were no apparent differences in any of the safety assessment parameters between the groups, and the overall incidence of study-related adverse events was low.
Collapse
Affiliation(s)
- Claire Martin Leroy
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland
| | | | | | | | | | | |
Collapse
|
16
|
Tricker AR, Kanada S, Takada K, Martin Leroy C, Lindner D, Schorp MK, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 6: 6-Day randomized clinical trial of a menthol cigarette in Japan. Regul Toxicol Pharmacol 2012; 64:S64-73. [PMID: 22951347 DOI: 10.1016/j.yrtph.2012.08.007] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 11/29/2022]
Abstract
A randomized, controlled, open-label, parallel-group, single-center study to determine biomarkers of exposure to 12 selected harmful and potentially harmful constituents (HPHC) in cigarette smoke, excretion of mutagenic material in urine, and serum Clara cell 16-kDa protein (CC16) in 102 male and female Japanese subjects who smoked Marlboro Ultra Lights Menthol cigarettes (M4J(M); 4 mg tar and 0.3mg nicotine) at baseline. Subjects were randomized to continue smoking M4J(M), or switch to smoking either the Electrically Heated Cigarette Smoking System menthol cigarette (EHCSS-K6(M); 5mg tar and 0.3mg nicotine) or the Lark One menthol cigarette (Lark1(M); 1mg tar and 0.1mg nicotine), or to no-smoking. The mean decreases from baseline to Day 5/6 were statistically significant (p ≤ 0.05) for exposure to 10 of 12 cigarette smoke HPHC including the primary endpoint (carbon monoxide) and urinary excretion of mutagenic material in the EHCSS-K6(M) group (-12.3% to -83.4%). Smaller, but statistically significant reductions (p ≤ 0.05) occurred in the Lark1(M) group (-3.3% to -35.2%), with the exception of urinary mutagens. The largest mean reductions (all p ≤ 0.05) in exposure to cigarette smoke HPHC and excretion of mutagenic material occurred in the no-smoking group (-1.4% to -93.6%). Serum CC16, an indicator of lung epithelial injury, was not significantly different between groups.
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
17
|
Zenzen V, Diekmann J, Gerstenberg B, Weber S, Wittke S, Schorp MK. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 2: Smoke chemistry and in vitro toxicological evaluation using smoking regimens reflecting human puffing behavior. Regul Toxicol Pharmacol 2012; 64:S11-34. [PMID: 22922180 DOI: 10.1016/j.yrtph.2012.08.004] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 11/28/2022]
Abstract
Chemical analysis of up to 49 harmful and potentially harmful constituents (HPHC) in mainstream smoke, in vitro cytotoxicity of the particulate and gas/vapor phase of mainstream smoke determined in the Neutral Red Uptake assay, and in vitro bacterial mutagenicity of the particulate phase determined in the Salmonella typhimurium Reverse Mutation (Ames) assay are reported for three Electrically Heated Cigarette Smoking System (EHCSS) series-K cigarettes, the University of Kentucky Reference Cigarette 2R4F, and a number of comparator commercial conventional lit-end cigarettes (CC) under ISO machine-smoking conditions and a total of 25 additional smoking regimens reflecting 'human puffing behavior' (HPB). The smoking machines were set to deliver nicotine yields for the EHCSS and comparator CC derived from the 10th percentile to the 90th percentile of nicotine uptake distributions in smokers determined in two clinical studies. Duplication of the smoking intensity 'per cigarette' on a smoking machine may provide an insight into product performance that is directly relevant to obtaining scientific evidence for reduced exposure substantiation based on mainstream cigarette smoke HPHC-to-nicotine regressions. The reported data support an overall evaluation of reduced exposure to HPHC and biological activity.
Collapse
Affiliation(s)
- Volker Zenzen
- Philip Morris International R&D, Philip Morris Research Laboratories GmbH, Fuggerstrasse 3, 51149 Cologne, Germany
| | | | | | | | | | | |
Collapse
|
18
|
Tricker AR, Stewart AJ, Leroy CM, Lindner D, Schorp MK, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 3: Eight-day randomized clinical trial in the UK. Regul Toxicol Pharmacol 2012; 64:S35-44. [PMID: 22940436 DOI: 10.1016/j.yrtph.2012.08.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/26/2023]
Abstract
A randomized, controlled, open-label, parallel-group, single-center study to determine biomarkers of exposure to nine selected harmful and potentially harmful constituents (HPHC) in cigarette smoke and urinary excretion of mutagenic material in 160 male and female subjects smoking Marlboro cigarettes (6 mg tar, 0.5mg nicotine, and 7.0mg CO) at baseline. Subjects were randomized to continue smoking Marlboro cigarettes, or switch to using an Electrically Heated Cigarette Smoking System (EHCSS) smoking one of two EHCSS series-K cigarettes, the EHCSS-K6 cigarette (5mg tar, 0.3mg nicotine, and 0.6 mg CO) or the EHCSS-K3 cigarette (3mg tar, 0.2mg nicotine, and 0.6 mg CO), or switch to smoking Philip Morris One cigarettes (1mg tar, 0.1mg nicotine, and 2.0mg CO), or to no-smoking. The mean decreases from baseline to Day 8 were statistically significant (p ≤ 0.05) for all determined HPHC including benzene and CO (the primary objectives), and urinary excretion of mutagenic material in the EHCSS-K6 (range -35.5 ± 29.2% to -79.4 ± 14.6% [mean ± standard deviation]), EHCSS-K3 (range -41.2 ± 26.6% to -83.1 ± 9.2%), and PM1 (range -14.6 ± 24.1% to -39.4 ± 17.5%) groups. The largest reductions in exposure occurred in the no-smoking group (range -55.4 ± 45.0% to -100.0 ± 0.0%).
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | | | |
Collapse
|
19
|
Schorp MK, Tricker AR, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 1: Non-clinical and clinical insights. Regul Toxicol Pharmacol 2012; 64:S1-10. [PMID: 22940435 DOI: 10.1016/j.yrtph.2012.08.008] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/16/2023]
Abstract
The following series of papers presents an extensive assessment of the Electrically Heated Cigarette Smoking System EHCSS series-K cigarette vs. conventional lit-end cigarettes (CC) as an example for an extended testing strategy for evaluation of reduced exposure. The EHCSS produces smoke through electrical heating of tobacco. The EHCSS series-K heater was designed for exclusive use with EHCSS cigarettes, and cannot be used to smoke (CC). Compared to the University of Kentucky Reference Research cigarette 2R4F and a series of commercial CC, mainstream cigarette smoke of both the non-menthol and menthol-flavored EHCSS cigarettes showed a reduced delivery of a series of selected harmful and potentially harmful constituents (HPHC), mutagenic activity determined using the Salmonella typhimurium Reverse Mutation (Ames) assay, and cytotoxicity in the Neutral Red Uptake Assay. Clinical evaluations confirmed reduced exposure to HPHC and excretion of mutagenic material under controlled clinical conditions. Reductions in HPHC exposure were confirmed in a real-world ambulatory clinical study. Potential biomarkers of cardiovascular risk were also reduced under real-world ambulatory conditions. A modeling approach, 'nicotine bridging', was developed based on the determination of nicotine exposure in clinical evaluations which indicated that exposure to HPHC for which biomarkers of exposure do not exist would also be reduced.
Collapse
Affiliation(s)
- Matthias K Schorp
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | |
Collapse
|
20
|
Tricker AR, Kanada S, Takada K, Leroy CM, Lindner D, Schorp MK, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 5: 8-Day randomized clinical trial in Japan. Regul Toxicol Pharmacol 2012; 64:S54-63. [PMID: 22940437 DOI: 10.1016/j.yrtph.2012.08.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/09/2023]
Abstract
A randomized, controlled, open-label, parallel-group, single-center study to determine biomarkers of exposure to twelve selected harmful and potentially harmful constituents (HPHCs) in cigarette smoke and urinary excretion of mutagenic material in 128 male and female Japanese subjects smoking Marlboro cigarettes (6 mg tar, 0.5mg nicotine, and 7.0mg CO) at baseline. Subjects were randomized to continue smoking Marlboro cigarettes, or switch to the Electrically Heated Cigarette Smoking System (EHCSS) and smoke either the EHCSS-K6 (5mg tar, 0.3mg nicotine, and 0.6 mg CO) or the EHCSS-K3 (3mg tar, 0.2mg nicotine, and 0.6 mg CO) cigarette, or switch to smoking Lark One cigarettes (1mg tar, 0.1mg nicotine, and 2.0mg CO), or to no-smoking. The mean decreases from baseline to Day 8 were statistically significant (p ≤ 0.05) for all cigarette smoke HPHC including CO (the primary objective) and excretion of mutagenic material in the EHCSS-K6 (range: -14.6% to -75.6%) and EHCSS-K3 (range: -9.8% to -73.0%) groups. Statistically significant reductions (all p ≤ 0.05) in exposure to ten cigarette smoke HPHC (range: -5.9% to -34.6%), but not urinary mutagenicity, were observed in the Lark One group. The largest mean reductions in exposure to HPHC (all p ≤ 0.01 level) occurred in the no-smoking group (range: -13.7% to -97.6%).
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | | | | | |
Collapse
|