Boschi A, Uccelli L, Marvelli L, Cittanti C, Giganti M, Martini P. Technetium-99m Radiopharmaceuticals for Ideal Myocardial Perfusion Imaging: Lost and Found Opportunities. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27041188. [PMID: 35208982 PMCID: PMC8877792 DOI: 10.3390/molecules27041188] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/06/2022] [Accepted: 02/08/2022] [Indexed: 02/07/2023]
Abstract
The favorable nuclear properties in combination with the rich coordination chemistry make technetium-99m the radioisotope of choice for the development of myocardial perfusion tracers. In the early 1980s, [99mTc]Tc-Sestamibi, [99mTc]Tc-Tetrofosmin, and [99mTc]Tc-Teboroxime were approved as commercial radiopharmaceuticals for myocardial perfusion imaging in nuclear cardiology. Despite its peculiar properties, the clinical use of [99mTc]Tc-Teboroxime was quickly abandoned due to its rapid myocardial washout. Despite their widespread clinical applications, both [99mTc]Tc-Sestamibi and [99mTc]Tc-Tetrofosmin do not meet the requirements of an ideal perfusion imaging agent due to their relatively low first-pass extraction fraction and high liver absorption. An ideal radiotracer for myocardial perfusion imaging should have a high myocardial uptake; a high and stable target-to-background ratio with low uptake in the lungs, liver, stomach during the image acquisition period; a high first-pass myocardial extraction fraction and very rapid blood clearance; and a linear relationship between radiotracer myocardial uptake and coronary blood flow. Although it is difficult to reconcile all these properties in a single tracer, scientific research in the field has always channeled its efforts in the development of molecules that are able to meet the characteristics of ideality as much as possible. This short review summarizes the developments in 99mTc myocardial perfusion tracers, which are able to fulfill hitherto unmet medical needs and serve a large population of patients with heart disease, and underlines their strengths and weaknesses, the lost and found opportunities thanks to the developments of the new ultrafast SPECT technologies.
Collapse
Affiliation(s)
- Alessandra Boschi
- Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
- Correspondence: ; Tel.:+39-0532-455354
| | - Licia Uccelli
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Lorenza Marvelli
- Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
| | - Corrado Cittanti
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Melchiore Giganti
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Petra Martini
- Department of Environmental and Prevention Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
| |
Collapse
|
2
|
Mantha S. Rational Cardiac Risk Stratification Before Peripheral Vascular Surgery: Application of Evidence-Based Medicine and Bayesian Analysis. Semin Cardiothorac Vasc Anesth 2016. [DOI: 10.1177/108925320000400402] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Srinivas Mantha
- Department of Anesthesiology & Intensive Care, Nizam's Institute of Medical Sciences, Hyderabad, India
| |
Collapse
|
3
|
Stochkendahl MJ, Mickley H, Vach W, Aziz A, Christensen HW, Hartvigsen J, Høilund-Carlsen PF. Clinical characteristics, myocardial perfusion deficits, and clinical outcomes of patients with non-specific chest pain hospitalized for suspected acute coronary syndrome: A 4-year prospective cohort study. Int J Cardiol 2015; 182:126-31. [DOI: 10.1016/j.ijcard.2014.12.054] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Accepted: 12/21/2014] [Indexed: 11/25/2022]
|
4
|
Swidan MM, Sakr TM, Motaleb MA, El-Bary AA, El-Kolaly MT. Radioiodinated acebutolol as a new highly selective radiotracer for myocardial perfusion imaging. J Labelled Comp Radiopharm 2014; 57:593-9. [DOI: 10.1002/jlcr.3223] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 06/17/2014] [Accepted: 07/03/2014] [Indexed: 11/12/2022]
Affiliation(s)
- M. M. Swidan
- Labeled Compound Department; Hot Labs Center, Atomic Energy Authority; PO13759 Cairo Egypt
| | - T. M. Sakr
- Radioactive Isotopes and Generator Department; Hot Labs Center, Atomic Energy Authority; PO13759 Cairo Egypt
| | - M. A. Motaleb
- Labeled Compound Department; Hot Labs Center, Atomic Energy Authority; PO13759 Cairo Egypt
| | - A. Abd El-Bary
- Pharmaceutics and Industrial Pharmacy Department; Faculty of Pharmacy, Cairo University; PO11562 Cairo Egypt
| | - M. T. El-Kolaly
- Labeled Compound Department; Hot Labs Center, Atomic Energy Authority; PO13759 Cairo Egypt
| |
Collapse
|
5
|
Hamad EA, Travin MI. The Complementary Roles of Radionuclide Myocardial Perfusion Imaging and Cardiac Computed Tomography. Semin Roentgenol 2012; 47:228-39. [DOI: 10.1053/j.ro.2011.11.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
6
|
Long-term prognostic value of CFVR and FFR versus perfusion scintigraphy in patients with multivessel disease. Neth Heart J 2011; 15:369-74. [PMID: 18176638 DOI: 10.1007/bf03086017] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
OBJECTIVE In this multicentre study, we investigated the long-term prognostic value of intracoronary derived haemodynamic parameters compared with the results of myocardial perfusion scintigraphy (MPS). METHODS Patients (n=191) who were referred for angioplasty of a severe lesion in the presence of an intermediate lesion in another coronary artery were included. MPS was performed to determine the presence of reversible perfusion defects in the area of the intermediate lesion. Coronary flow velocity reserve (CFVR), and additionally fractional flow reserve (FFR; n=129), were determined distal to the intermediate lesion; CFVR >/=2.0 and FFR >/=0.75 were considered negative. RESULTS In total 67 events occurred in 49 patients (3 deaths, 9 MI, 9 CABG, 46 PTCA) during a mean of 793 days follow-up. Event-free survival was 63% for MPS, 79% for CFVR, and 79% for FFR if a negative test result was obtained. The relative risk was 1.2 (not significant) for MPS, 2.2 (p=0.001) for CFVR, and 2.4 (p=0.004) for FFR. CONCLUSION Selective evaluation of an intermediate lesion using CFVR or FFR allows more adequate risk stratification in patients with multivessel disease than MPS. A CFVR <2.0 or a FFR <0.75 was associated with a significant increase of the occurrence of cardiac events during long-term follow-up, predominantly associated with revascularisation. (Neth Heart J 2007;15:369-74.).
Collapse
|
7
|
Evaluation of (99) (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99) (m)Tc-sestamibi. Mol Imaging Biol 2011; 13:121-7. [PMID: 20458635 DOI: 10.1007/s11307-010-0304-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE (99) (m)TcN-MPO ([(99) (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99) (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99) (m)TcN-MPO and (99) (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99) (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. METHODS Five normal mongrel dogs were injected intravenously with (99) (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99) (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99) (m)TcN-MPO (n = 4) or (99) (m)Tc-Sestamibi (n = 4). RESULTS It was found that (99) (m)TcN-MPO and (99) (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99) (m)TcN-MPO and (99) (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99) (m)TcN-MPO and (99) (m)Tc-Sestamibi both showed good heart/lung contrast. The heart/liver ratio of (99) (m)TcN-MPO increased with time (0.53 ± 0.06 at 10 min, 0.90 ± 0.062 at 30 min, and 1.22 ± 0.06 at 60 min p.i.), whereas the heart/liver ratio of (99) (m)Tc-Sestamibi remained low at all time points (0.50 ± 0.03 at 10 min, 0.64 ± 0.03 at 30 min, and 0.60 ± 0.02 at 60 min p.i.). SPECT imaging studies in canines with acute myocardial infarction indicated that good visualization of the left ventricular wall and perfusion defects could be achieved at 30 min after administration of (99) (m)TcN-MPO but not after (99) (m)Tc-Sestamibi. CONCLUSION The combination of reasonable heart uptake with rapid hepatobiliary excretion makes (99) (m)TcN-MPO a promising new radiotracer for myocardial perfusion imaging.
Collapse
|
8
|
[Exclusion of coronary artery disease using cardiac CT. What impact do CT results have on patient management?]. Clin Res Cardiol Suppl 2011; 6:25-31. [PMID: 22528175 DOI: 10.1007/s11789-011-0030-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Rapid advancement of multidetector head computed tomography (MDCT) during the past 10 years has facilitated noninvasive evaluation of CAD (coronary artery disease). Since the introduction of 320-row technology, examination of the whole heart in a single heart beat with diagnostic quality has become feasible. Direct imaging of vessel morphology, a high sensitivity for CAD above 96%, and low requirements of patient compliance represent advantages over other imaging modalities, such as MRI (magnetic resonance imaging), scintigraphy, and echocardiography. In some cases radiation exposure can be reduced to an effective dose below 1 mSV.Current data suggest that cardiac CT represents a more effective diagnostic tool than treadmill testing in order to decide whether cardiac catheterization is indicated. Treadmill testing has been an integral procedure of cardiac examinations for decades, although sensitivity for detecting CAD is as low as 70%.Cardiac CT represents a rather new modality and is almost exclusively performed in diagnostic imaging centers. Innovative concepts in the evaluation of CAD including CT are expected. Some authors propose cardiac CT as a major diagnostic tool for the exclusion of CAD. MRI, scintigraphy, or echocardiography in combination with a stress test remain important procedures in order to evaluate the hemodynamic relevance of coronary artery stenosis. Treadmill testing prior to cardiac CT has become questionable.The future role of cardiac CT in CAD in "change of management" concepts is promising. In order to optimize decisions of patient management on the basis of a cardiac CT examinations, awareness of current data is mandatory for the referring clinician and the performing radiological department.
Collapse
|
9
|
Dörr R, Sternitzky R. [Non-invasive diagnostics of chronic stable coronary artery disease: evidence-based and non-evidence-based diagnostic algorithms]. Clin Res Cardiol Suppl 2011; 6:17-24. [PMID: 22528174 DOI: 10.1007/s11789-011-0027-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In Germany, every second left heart catheterization has no immediate interventional or surgical consequence. One main reason for this limited quality of indication of many left heart catheterizations is presumably the inaccuracy of preinvasive testing that is mainly based on clinical evaluation and exercise ECG in Germany. However, exercise electrocardiography has several limitations. The central issues are the inability to exercise in many, especially elderly patients, and the missing interpretability of the stress ECG in cases with already pathological rest ECG. In 2006, the "Nationale Versorgungsleitlinie Chronische KHK (NVL KHK)" was published in Germany, adopting for the first time the evidence-based algorithms of the American College of Cardiology/American Heart Association (ACC/AHA) guidelines for non-invasive stress testing and complementary stress imaging. Stress imaging methods considered comparable and interchangeable are the following: stress echocardiography combined with physical or pharmacological stress testing, myocardial perfusion imaging with physical or pharmacological stress testing, dobutamine stress magnetic resonance imaging (DSMR), or myocardial perfusion magnetic resonance imaging (MRI). Basically, no stress imaging method is definitely superior to the others, each method has its own advantages and disadvantages that should be considered and adjusted to the individual patient. Of pivotal importance of all stress imaging methods is the high negative predictive value of 99% of a normal study predicting a very low (< 1%) cumulative likelihood of cardiac death or myocardial infarction for at least the next 12 months. Hence, in most clinical circumstances, coronary angiography is not necessary during the 12 months subsequent to a normal stress imaging study. In contrast to these established and evidence-based recommendations of the "Nationale Versorgungsleitlinie Chronische KHK" mainly focusing on ischemia stress imaging, many diagnostic centers have developed their own non-evidence based algorithms. In these non-evidence based algorithms the morphology-oriented non-invasive CT coronary angiography has taken over the diagnostic part of evidence-based ischemia stress imaging. However, beyond the scientifically established prognostic value of calcium scoring, there is so far no scientific evidence showing that morphology-oriented CT coronary angiography protocols are superior to functional stress imaging. A new innovative approach of staged non-invasive diagnostics for patients with intermediate likelihood (10-90%) of coronary artery disease are the 2010 recommendations of the National Institute for Health and Clinical Excellence (NICE) guiding the National Health Service (NHS) in the United Kingdom. Following this guidance, in patients with an estimated likelihood of CAD of 10-29% CT calcium scoring should be offered as first-line method, in patients with an estimated likelihood of CAD of 30-60% non-invasive functional imaging should be offered primarily, and in patients with an estimated likelihood of CAD of 61-90%, as in patients with an estimated likelihood of CAD of more than 90%, invasive coronary angiography should be preferred.
Collapse
Affiliation(s)
- Rolf Dörr
- Praxisklinik Herz und Gefässe, Kardiologie, Angiologie, Radiologie, Nuklearmedizin, Akademische Lehrpraxisklinik der TU Dresden, Forststrasse 3, Dresden, Germany.
| | | |
Collapse
|
10
|
Abstract
The musculoskeletal system is a recognized source of chest pain. However, despite the apparently benign origin, patients with musculoskeletal chest pain remain under-diagnosed, untreated, and potentially continuously disabled in terms of anxiety, depression, and activities of daily living. Several overlapping conditions and syndromes of focal disorders, including Tietze syndrome, costochondritis, chest wall syndrome, muscle tenderness, slipping rib, cervical angina, and segmental dysfunction of the cervical and thoracic spine, have been reported to cause pain. For most of these syndromes, evidence arises mainly from case stories and empiric knowledge. For segmental dysfunction, clinical features of musculoskeletal chest pain have been characterized in a few clinical trials. This article summarizes the most commonly encountered syndromes of focal musculoskeletal disorders in clinical practice.
Collapse
|
11
|
Karlsberg RP, Budoff MJ, Thomson LEJ, Friedman JD, Berman DS. Reduction in downstream test utilization following introduction of coronary computed tomography in a cardiology practice. Int J Cardiovasc Imaging 2010; 26:359-66. [PMID: 19967562 PMCID: PMC2846332 DOI: 10.1007/s10554-009-9547-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2009] [Accepted: 11/18/2009] [Indexed: 12/22/2022]
Abstract
To compare utilization of non-invasive ischemic testing, invasive coronary angiography (ICA), and percutaneous coronary intervention (PCI) procedures before and after introduction of 64-slice multi-detector row coronary computed tomographic angiography (CCTA) in a large urban primary and consultative cardiology practice. We utilized a review of electronic medical records (NotesMD) and the electronic practice management system (Megawest) encompassing a 4-year period from 2004 to 2007 to determine the number of exercise treadmill (TME), supine bicycle exercise echocardiography (SBE), single photon emission computed tomography (SPECT) myocardial perfusion stress imaging (MPI), coronary calcium score (CCS), CCTA, ICA, and PCI procedures performed annually. Test utilization in the 2 years prior to and 2 years following availability of CCTA were compared. Over the 4-year period reviewed, the annual utilization of ICA decreased 45% (2,083 procedures in 2004 vs. 1,150 procedures in 2007, P < 0.01) and the percentage of ICA cases requiring PCI increased (19% in 2004 vs. 28% in 2007, P < 0.001). SPECT MPI decreased 19% (3,223 in 2004 vs. 2,614 in 2007 P < 0.02) and exercise stress treadmill testing decreased 49% (471 in 2004 vs. 241 in 2007 P < 0.02). Over the same period, there were no significant changes in measures of practice volume (office and hospital) or the annual incidence of PCI (405 cases in 2004 vs. 326 cases in 2007) but a higher percentage of patients with significant disease undergoing PCI 19% in 2004 vs. 29% in 2007 P < 0.01. Implementation of CCTA resulted in a significant decrease in ICA and a corresponding significant increase in the percentage of ICA cases requiring PCI, indicating that CCTA resulted in more accurate referral for ICA. The reduction in unnecessary ICA is associated with avoidance of potential morbidity and mortality associated with invasive diagnostic testing, reduction of downstream SPECT MPI and TME as well as substantial savings in health care dollars.
Collapse
Affiliation(s)
- Ronald P Karlsberg
- Cardiovascular Research Foundation of Southern California, Beverly Hills, CA, USA.
| | | | | | | | | |
Collapse
|
12
|
Kim YS, Wang F, Liu S. Minimizing liver uptake of cationic Tc radiotracers with ether and crown ether functional groups. World J Hepatol 2010; 2:21-31. [PMID: 21160953 PMCID: PMC2999265 DOI: 10.4254/wjh.v2.i1.21] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Revised: 01/11/2010] [Accepted: 01/18/2010] [Indexed: 02/06/2023] Open
Abstract
Ischemia-related diseases, particularly coronary artery disease (CAD), account for the majority of deaths worldwide. Myocardial ischemia is a serious condition and the delay in reperfusion of ischemic tissues can be life-threatening. This is particular true in the aged population. Rapid and accurate early detection of myocardial ischemia is highly desirable so that various therapeutic regiments can be given before irreversible myocardial damage occurs. Myocardial perfusion imaging with radiotracers is an integral component in evaluations of patients with known or suspected CAD. (99m)Tc-Sestamibi and (99m)Tc-Tetrofosmin are commercial radiopharmaceuticals currently available for myocardial perfusion imaging. Despite their widespread clinical applications, both (99m)Tc-Sestamibi and (99m)Tc-Tetrofosmin do not meet the requirements of an ideal perfusion imaging agent, largely due to their high liver uptake. The intense liver uptake makes it difficult to interpret the heart activity in the inferior and left ventricular wall. Photon scattering from the high liver radioactivity accumulation remains a significant challenge for diagnosis of heart diseases. This review will summarize the most recent research efforts to minimize the liver uptake of cationic (99m)Tc radiotracers by using ether and crown ether-containing chelators. Fast liver clearance will shorten the duration of imaging protocols (< 30 min post-injection), and allow for early acquisition of heart images with high quality. Improvement of heart/liver ratio may permit better detection of the presence and extent of coronary artery disease. Identification of such a new radiotracer that allows for the improved noninvasive assessment of myocardial perfusion would be of considerable benefit in treatment of patients with suspected CAD.
Collapse
Affiliation(s)
- Young-Seung Kim
- Young-Seung Kim, Shuang Liu, School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907, United States
| | | | | |
Collapse
|
13
|
Hines JL, Danciu SC, Shah M, Borg MJ, Biga C. Use of multidetector computed tomography after mildly abnormal myocardial perfusion stress testing in a large single-specialty cardiology practice. J Cardiovasc Comput Tomogr 2008; 2:372-8. [DOI: 10.1016/j.jcct.2008.09.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2008] [Revised: 08/14/2008] [Accepted: 09/20/2008] [Indexed: 11/28/2022]
|
14
|
Evaluation of 99mTcN-15C5 as a new myocardial perfusion imaging agent in normal dogs and canines with coronary stenosis. Nucl Med Commun 2008; 29:775-81. [PMID: 18677204 DOI: 10.1097/mnm.0b013e328302ca4a] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study was designed to evaluate the biodistribution and blood clearance characteristics of 99mTcN-15C5 and its potential as a myocardial perfusion radiotracer. METHODS Five normal mongrel dogs were injected with 99mTcN-15C5 intravenously. Blood samples were collected at 0.5, 1, 2, 3, 4, 5, 10, 15, and 30 min postinjection (p.i.). Anterior planar images were acquired at 5, 15, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around heart, liver, and lungs. The raw activity in each ROI was expressed as counts/pixel/min. Heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in liver and lung ROI, respectively. For comparison, 99mTc-sestamibi was also evaluated in the same five dogs. In dogs with coronary stenoses, single photon emission computed tomography images were acquired at 30, 60, and 120 min after administration of 99mTcN-15C5 with/without adenosine. RESULTS 99mTcN-15C5 and 99mTc-sestamibi had very similar blood clearance characteristics during the first 30 min p.i. The heart/liver ratio of 99mTcN-15C5 increased from 0.48+/-0.05 at 5 min p.i. to 1.85+/-0.11 at 120 min p.i., whereas the heart/liver ratio of 99mTc-sestamibi was improved only slightly from 0.45+/-0.04 at 5 min p.i. to 0.74+/-0.15 at 120 min p.i. SPECT imaging studies in canines with coronary stenoses indicated that good visualization of the perfusion defect could be achieved at 30 min after administration of 99mTcN-15C5 with the adenosine stress. CONCLUSION The combination of high heart uptake and rapid liver clearance makes 99mTcN-15C5 a promising new radiotracer for myocardial perfusion imaging.
Collapse
|
15
|
Lachance P, Déry JP, Rodés-Cabau J, Potvin JM, Barbeau G, Bertrand OF, Gleeton O, Larose E, Nguyen CM, Noël B, Proulx G, Roy L, De Larochellière R. Impact of fractional flow reserve measurement on the clinical management of patients with coronary artery disease evaluated with noninvasive stress tests prior to cardiac catheterization. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2008; 9:229-34. [DOI: 10.1016/j.carrev.2008.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2007] [Revised: 02/15/2008] [Accepted: 02/19/2008] [Indexed: 11/24/2022]
|
16
|
|
17
|
Tc-99m-N-MPO: novel cationic Tc-99m radiotracer for myocardial perfusion imaging. J Nucl Cardiol 2008; 15:535-46. [PMID: 18674722 DOI: 10.1016/j.nuclcard.2008.02.022] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2007] [Accepted: 02/21/2008] [Indexed: 11/21/2022]
Abstract
BACKGROUND Technetium 99m-N-MPO ([Tc-99m-N(mpo)(PNP5)](+)) is a cationic Tc-99m nitrido complex. The objective of this study is to evaluate its potential as a new radiotracer for myocardial perfusion imaging. METHODS AND RESULTS Biodistribution studies were performed in Sprague-Dawley rats and guinea pigs to compare the myocardial uptake and excretion kinetics of Tc-99m-N-MPO from noncardiac organs, such as the liver and lungs, with those of the known cationic Tc-99m radiotracers: Tc-99m-N-DBODC5 and Tc-99m-sestamibi. Planar imaging was performed in Sprague-Dawley rats to evaluate the utility of Tc-99m-N-MPO as a myocardial perfusion imaging agent. Metabolism studies were carried out by use of both Sprague-Dawley rats and guinea pigs. In general, the heart uptake of Tc-99m-N-MPO was between that of Tc-99m-sestamibi and Tc-99m-N-DBODC5 over the 2-hour study period. However, the heart-liver ratio of Tc-99m-N-MPO (12.75 +/- 3.34) at 30 minutes after injection was more than twice that of Tc-99m-N-DBODC5 (6.01 +/- 1.45) and approximately 4 times higher than that of Tc-99m-sestamibi (2.90 +/- 0.22). The heart uptake and heart-liver ratio of Tc-99m-N-MPO and Tc-99m-sestamibi in guinea pigs were significantly lower than those obtained in Sprague-Dawley rats. The metabolism studies demonstrated no detectable Tc-99m-N-MPO metabolites in the urine and feces samples of the Sprague-Dawley rats at 120 minutes after injection. In guinea pigs no Tc-99m-N-MPO metabolites were detected in the urine at 120 minutes, but only approximately 60% of Tc-99m-N-MPO remained intact in the feces samples. In contrast, there was no intact Tc-99m-sestamibi detected in urine samples, and less than 15% of Tc-99m-sestamibi remained intact in the feces samples. Planar imaging studies indicated that clinically useful images of the heart may be obtained as early as 15 minutes after injection of Tc-99m-N-MPO. CONCLUSION The combination of favorable organ biodistribution and myocardial uptake with rapid liver clearance makes Tc-99m-N-MPO a very promising myocardial perfusion radiotracer worthy of further evaluation in various preclinical animal models.
Collapse
|
18
|
Liu S. Ether and crown ether-containing cationic 99mTc complexes useful as radiopharmaceuticals for heart imaging. Dalton Trans 2007:1183-93. [PMID: 17353949 DOI: 10.1039/b618406e] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
While radiopharmaceutical research has been focused on the development of target-specific radiotracers for early detection and radiotherapy of cancers in the last decade, there is a limited effort on new cationic 99mTc radiotracers for heart imaging. This review will summarize some of the most recent developments in ether- and crown ether-containing cationic 99mTc radiotracers that have a fast liver clearance with a heart/liver ratio substantially better than that of 99mTc-Sestamibi and 99mTc-Tetrofosmin, the two commercial 99mTc radiopharmaceuticals currently available for myocardial perfusion imaging. Fast liver clearance might shorten the duration of imaging protocols (<30 min post-injection), and allow for early acquisition of heart images of high quality. Improvement of heart/liver ratio may permit better detection of the presence and extent of coronary artery disease. Identification of such a new radiotracer that allows for the improved non-invasive delineation of myocardial perfusion would be of considerable benefit in treatment of patients with suspected coronary artery disease.
Collapse
Affiliation(s)
- Shuang Liu
- School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907, USA.
| |
Collapse
|
19
|
Travin MI. Revascularize only for ischemia, especially if left ventricular function is poor. J Nucl Cardiol 2006; 13:742-6. [PMID: 17174803 DOI: 10.1016/j.nuclcard.2006.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
20
|
Liu S, He Z, Hsieh WY, Kim YS. Evaluation of novel cationic (99m)Tc-nitrido complexes as radiopharmaceuticals for heart imaging: improving liver clearance with crown ether groups. Nucl Med Biol 2006; 33:419-32. [PMID: 16631092 DOI: 10.1016/j.nucmedbio.2006.01.005] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2005] [Revised: 12/19/2005] [Accepted: 01/03/2006] [Indexed: 10/24/2022]
Abstract
This report describes the evaluation of a series of novel cationic (99m)Tc-nitrido complexes, [(99m)TcN(DTC)(PNP)]+ (DTC = crown ether-containing dithiocarbamates; PNP = bisphosphine), as potential radiotracers for myocardial perfusion imaging. Synthesis of cationic (99m)Tc-nitrido complexes was accomplished in two steps according to literature methods. Biodistribution studies were performed in rats. Planar images of Sprague-Dawley rats administered with 15+/-2 MBq of cationic (99m)Tc radiotracer were obtained using a PhoGama large field-of-view Anger camera. Samples from both urine and feces were analyzed by a reversed-phase radio-HPLC method. Results from biodistribution studies showed that most of the cationic (99m)Tc-nitrido complexes have a high initial heart uptake with a long myocardial retention. They also show a rapid clearance from the liver and lungs. Cationic complexes [(99m)TcN(L2)(L6)]+ and [(99m)TcN(L4)(L6)]+ show heart/liver ratios four to five times better than that of (99m)Tc-sestamibi due to their much faster liver clearance. Their heart uptake and heart/liver ratio are comparable to that of (99m)TcN-DBODC5 within the experimental error. These findings have been confirmed by the results from imaging studies. Radio-HPLC analysis of urine and feces samples indicated that there was very little metabolism of cationic (99m)Tc-nitrido complexes in rats under anesthesia. The key finding of this study is that lipophilicity remains the most important factor affecting both heart uptake and target-to-background (T/B) ratios. Crown ethers are very useful functional groups to improve the liver clearance of cationic (99m)Tc-nitrido complexes. It is the combination of the appropriate DTCs and bisphosphines that results in cationic (99m)Tc-nitrido complexes with high heart uptake and fast clearance from the liver at the same time. The fast liver clearance of [(99m)TcN(L2)(L6)]+ and [(99m)TcN(L4)(L6)]+ suggests that they might be used to obtain clinically useful images as early as 30 min postinjection. [(99m)TcN(L2)(L6)]+ and [(99m)TcN(L4)(L6)]+ are very promising candidates for further evaluation in more extensive preclinical animal models.
Collapse
Affiliation(s)
- Shuang Liu
- School of Health Sciences, Purdue University, Lafayette, IN 47907, USA.
| | | | | | | |
Collapse
|
21
|
El-Ali HH, Palmer J, Edenbrandt L, Ljungberg M. A model that accounts for the interdependence of extent and severity in the automatic evaluation of myocardial defects. Nucl Med Commun 2006; 27:127-35. [PMID: 16404225 DOI: 10.1097/01.mnm.0000195673.68040.d7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND The extent and severity are two important parameters when describing a regional defect in myocardial single-photon emission computed tomography (SPECT) perfusion imaging. Intuitively, these two parameters should be independent of each other, but we have shown in a previous study that there is an interdependence. This interdependence has been investigated in two commercially available analysis programs (AutoQUANT and 4D-MSPECT) using Monte Carlo-simulated SPECT data. METHODS An anthropomorphic digital computer phantom and a Monte Carlo program were used to generate SPECT data. Several defects of different volumes and lesion activity uptake reductions were simulated and evaluated. Comparison of the measures of extent and severity with their corresponding known values led to the development of a correction model based on least-squares parameter estimation. This model was then applied to a test group consisting of 10 different computer-simulated patients. RESULTS Our results showed that the interdependence was reduced significantly for most of our test cases after applying the correction method. The application of the correction model to the test group demonstrated that the model was robust with respect to different patient geometries. A further test with projections that simulated a perfect SPECT system revealed that the interdependence between the extent and severity was not caused by the limited spatial resolution of the SPECT system, but rather the inherent design of the algorithms of the analysis programs. CONCLUSIONS A model has been developed to take into account the interdependence of the extent and severity.
Collapse
Affiliation(s)
- Henrik Hussein El-Ali
- Department of Medical Radiation Physics, Clinical Sciences, Lund University, Sweden.
| | | | | | | |
Collapse
|
22
|
Christensen HW, Vach W, Gichangi A, Manniche C, Haghfelt T, Høilund-Carlsen PF. Manual Therapy for Patients With Stable Angina Pectoris: A Nonrandomized Open Prospective Trial. J Manipulative Physiol Ther 2005; 28:654-61. [PMID: 16326234 DOI: 10.1016/j.jmpt.2005.09.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2005] [Revised: 06/06/2005] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To examine if participants with chest pain originating from the spine would benefit from manual therapy. METHODS A nonrandomized, open, prospective trial was performed at a tertiary hospital. Patients who were referred for coronary angiography because of known or suspected stable angina pectoris were invited to participate in this study. A total of 275 took part, 50 were diagnosed as cervicothoracic angina (CTA)-positive (chest pain from the cervicothoracic spine) and 225 as CTA-negative. The intervention performed was manual therapy according to chiropractic standards. Patient self reported questionnaires at baseline and 4-week follow-up, including pain measured with an 11-point box scale, Short Form 36 (quality of life), and perceived improvement. RESULTS Approximately 75% of CTA-positive patients reported improvement of pain and of general health after treatment, compared with 22% to 25% of CTA-negative patients (P < .0001). Pain intensity decreased in both groups with consistently larger decreases for all measures of pain among CTA-positive patients. Short Form 36 scores increased in the CTA-positive group in 5 of 8 scales and remained unchanged in the CTA-negative group. CONCLUSION This study suggested that patients with known or suspected angina pectoris and a diagnosis of CTA may benefit from chiropractic manual therapy. Methodologically, sound randomized clinical trials are needed to corroborate our results.
Collapse
|
23
|
Høilund-Carlsen PF, Johansen A, Christensen HW, Vach W, Møldrup M, Bartram P, Veje A, Haghfelt T. Potential impact of myocardial perfusion scintigraphy as gatekeeper for invasive examination and treatment in patients with stable angina pectoris: observational study without post-test referral bias. Eur Heart J 2005; 27:29-34. [PMID: 16183689 DOI: 10.1093/eurheartj/ehi503] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
AIMS To evaluate the impact of using myocardial perfusion scintigraphy (MPS) as gatekeeper for coronary angiography and revascularization in stable angina pectoris. METHODS AND RESULTS A prospective series of 507 out of 972 adult patients referred to coronary angiography for known or suspected stable angina pectoris underwent clinical examination followed immediately by MPS, the result of which was not communicated. MPS showed normal perfusion in 258/507 (51%) patients, reversible defects in 201/507 (40%), and fixed defects in 48/507 (9%). Of 168 revascularized patients, 27 (16%) had normal perfusion and 13 (8%) had fixed defects. Coronary angiography was undertaken in 476 patients of whom 252 (53%) had normal findings or insignificant stenoses. The same was the case in 361 (41%) out of the 883 of the 972 consecutive patients, who had this examination. Assuming that the true rate of normal perfusion in the entire series was correspondingly lower, 48% of catheterizations and 19% of revascularizations were superfluous. CONCLUSION The use of MPS as gatekeeper appears to make about half of catheterizations and almost one-fifth of revascularizations redundant. Even in high-risk groups, substantial savings are possible, and the risk of overlooking patients with severe disease seems negligible.
Collapse
|
24
|
Johansen A, Høilund-Carlsen PF, Christensen HW, Vach W, Møldrup M, Haghfelt T. Use of myocardial perfusion imaging to predict the effectiveness of coronary revascularisation in patients with stable angina pectoris. Eur J Nucl Med Mol Imaging 2005; 32:1363-70. [PMID: 15824925 DOI: 10.1007/s00259-005-1799-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2004] [Accepted: 02/28/2005] [Indexed: 02/01/2023]
Abstract
PURPOSE Coronary revascularisation is the treatment of choice in patients with stable angina who have significant stenoses. From a pathophysiological point of view, however, mitigation of angina is to be expected only in the presence of reversible ischaemia. Therefore it was the aim of this study to examine the effect of revascularisation on stable angina in relation to the myocardial perfusion imaging (MPI) pattern prior to intervention. METHODS Three hundred and eighty-four patients (58.0+/-8.8 years) referred for angiography underwent MPI. Prior to MPI and at 2-year follow-up, patients were classified as having typical angina, atypical angina, non-cardiac chest pain or no pain, and the severity of chest pain was graded according to the Canadian Cardiovascular Society (CCS) criteria. The patients themselves estimated their pain on a visual analogue scale. Management was based on symptoms and angiographic findings, since the results of MPI were not communicated. RESULTS Among the 240 patients who were not revascularised, 79% had typical or atypical angina at study entrance versus 40% at follow-up. In comparison, 93% of the 144 revascularised patients had typical or atypical angina before intervention versus only 36% at follow-up. This additional advantage of invasive therapy was present only in patients with reversible defects; revascularisation had no additional effect in patients with normal perfusion or irreversible defects. Similarly, additional, significant reductions in CCS class and visual analogue score were observed exclusively in patients with reversible defects. CONCLUSION In patients referred for coronary angiography owing to known or suspected stable angina, revascularisation was significantly more effective than medical treatment exclusively in patients with reversible ischaemia.
Collapse
Affiliation(s)
- Allan Johansen
- Department of Clinical Physiology and Nuclear Medicine, Odense University Hospital, Odense, Denmark.
| | | | | | | | | | | |
Collapse
|
25
|
Johansen A, Høilund-Carlsen PF, Christensen HW, Grupe P, Veje A, Vach W, Haghfelt T. Observer variability in the evaluation of dual-isotope Tl-201/Tc-99m sestamibi rest/stress myocardial perfusion SPECT in men and women with known or suspected stable angina pectoris. J Nucl Cardiol 2004; 11:710-8. [PMID: 15592195 DOI: 10.1016/j.nuclcard.2004.06.130] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Observer variability of dual-isotope myocardial perfusion imaging (MPI) with single photon emission computed tomography has rarely been investigated. The aim of our study was to evaluate the interpretive reproducibility with this technique. METHODS AND RESULTS We report on 507 patients with known or suspected stable angina who were studied before coronary angiography. A 1-day thallium 201/technetium 99m sestamibi rest/stress MPI protocol was used. MPI was interpreted by 2 independent observers without knowledge of clinical data, using a 20-segment scoring model. By consensus, the overall rate of abnormal MPI was 49% (59% in men and 34% in women). The interobserver agreement for the whole group (kappa = 0.85) and for men and women separately (kappa = 0.86 and 0.82, respectively) was excellent with regard to the overall diagnosis (normal, reversible, or fixed defects) as well as left anterior descending and left circumflex artery vascular territories (kappa = 0.85 and 0.82, respectively). However, in the right coronary artery territory, agreement was excellent in men (kappa = 0.83) but moderate in women (kappa = 0.57). CONCLUSIONS In a relatively large group of men and women with stable angina pectoris, interpretive reproducibility (overall and individual vessel diagnosis) was excellent, except in the right coronary artery territory of women, in which it was moderate.
Collapse
Affiliation(s)
- Allan Johansen
- Department of Nuclear Medicine, Odense University Hospital, Sdr Boulevard 29, DK-5000 Odense C, Denmark.
| | | | | | | | | | | | | |
Collapse
|
26
|
Visser JJN, Sokole EB, Verberne HJ, Habraken JBA, van de Stadt HJF, Jaspers JEN, Shehata M, Heeman PM, van Eck-Smit BLF. A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom. Eur J Nucl Med Mol Imaging 2004; 31:222-8. [PMID: 15129704 DOI: 10.1007/s00259-003-1352-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit into the Data Spectrum anthropomorphic torso phantom. Flexible silicone membranes form the inner and outer walls of the simulated left ventricle. Simulated LV volumes can be varied within the range 45-200 ml. The LV volume curve has a smooth and realistic clinical shape that is produced by a specially shaped cam connected to a piston. A fixed 70-ml stroke volume is applied for EF measurements. An ECG signal is produced at maximum LV filling by a controller unit connected to the pump. This gated cardiac phantom will be referred to as the Amsterdam 3-D gated cardiac phantom, or, in short, the AGATE cardiac phantom. SPET data were acquired with a triple-head SPET system. Data were reconstructed using filtered back-projection following pre-filtering and further processed with the Quantitative Gated SPECT (QGS) software to determine LV volume and EF values. Ungated studies were performed to measure LV volumes ranging from 45 ml to 200 ml. The QGS-determined LV volumes were systematically underestimated. For different LV combinations, the stroke volumes measured were consistent at 60-61 ml for 8-frame studies and 63-65 ml for 16-frame studies. QGS-determined EF values were slightly overestimated between 1.25% EF units for 8-frame studies and 3.25% EF units for 16-frame studies. In conclusion, the AGATE cardiac phantom offers possibilities for quality control, testing and validation of the whole gated cardiac SPET sequence, and testing of different acquisition and processing parameters and software.
Collapse
Affiliation(s)
- Jacco J N Visser
- Department of Nuclear Medicine, Academic Medical Center, Amsterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
González P, Massardo T, Coll C, Redondo F, Yovanovich J, Jofré J, Chamorro H, Humeres P, Sierralta P, Ramírez A, Kunstmann S, López H, Aramburú I, Brugère S. An assessment of wall motion, perfusion and glucose metabolism in recent myocardial infarction: a comparison in patients with and without revascularization. Nucl Med Commun 2003; 24:1155-65. [PMID: 14569170 DOI: 10.1097/00006231-200311000-00006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The aim of this study was to compare the extent and severity of wall motion abnormalities, perfusion and glucose metabolism, in recent myocardial infarction in patients with and without revascularization. Forty-nine patients were studied (82% men; mean age 58 years) by using echocardiography, 201Tl single photon emission computed tomography (SPECT) rest and redistribution, and 2-[18F]fluoro-2-deoxy-D-glucose (18F-FDG) SPECT at a mean of 9.2 days (range, 1-24 days) after myocardial infarction. Twenty-seven of the 49 patients underwent revascularization while the other 22 received medical therapy before echocardiography and studies using radionuclides. A contrast angiogram was obtained for each patient. A follow-up echocardiogram at 3 months was obtained for 44 patients. Images were read blindly, using a 17 segment model, with semi-quantitative analysis. In the whole group, the extent of hypokinesia was 15%+/-14 (mean+/-SD); the extent of mild defects was determined as 5%+/-6 by using 201Tl at rest, 6%+/-9 by using 201Tl redistribution, and 4%+/-6 by using 18F-FDG (P<0.0005, echocardiogram/radionuclides). Echocardiography showed that the extent of akinesia-dyskinesia was 16%+/-18 in revascularized patients and 28%+/-18 in non-revascularized patients (P=0.017). With regard to moderate and severe defects, 201Tl rest showed 19%+/-16 and 28%+/-17, respectively (P=0.047); 201Tl redistribution 17%+/-15 and 26%+/-15, respectively (P=0.043); and 18F-FDG 17%+/-13 and 24%+/-15, respectively (NS). In echocardiography, the extent of hypokinetic segments decreased from 16%+/-15 at baseline to 10%+/-11 at 3 months (P=0.045), in revascularized patients. It is concluded that, in recent myocardial infarction, hypokinesia extent on echocardiogram is greater than mild perfusion or metabolic defect extent, reflecting stunning and so the use of radionuclide techniques appear more accurate for defining the extent of myocardial infarction. Non-revascularized patients showed a significantly greater extent of akinesia-dyskinesia and moderate-severe perfusion defects than did revascularized patients, which can be considered a result of therapy. It is suggested that 201Tl rest perfusion be used for the assessment of myocardial infarction soon after revascularization.
Collapse
Affiliation(s)
- P González
- Nuclear Medicine and Cardiovascular Centers, University of Chile Clinical Hospital and Clinica Santa Maria, Santiago.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Chamuleau SAJ, Tio RA, de Cock CC, de Muinck ED, Pijls NHJ, van Eck-Smit BLF, Koch KT, Meuwissen M, Dijkgraaf MGW, de Jong A, Verberne HJ, van Liebergen RAM, Laarman GJ, Tijssen JGP, Piek JJ. Prognostic value of coronary blood flow velocity and myocardial perfusion in intermediate coronary narrowings and multivessel disease. J Am Coll Cardiol 2002; 39:852-8. [PMID: 11869852 DOI: 10.1016/s0735-1097(01)01821-6] [Citation(s) in RCA: 73] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
OBJECTIVES This study aimed to investigate the roles of intracoronary derived coronary flow velocity reserve (CFVR) and myocardial perfusion scintigraphy (single photon emission computed tomography, or SPECT) for management of an intermediate lesion in patients with multivessel coronary artery disease. BACKGROUND Evaluation of the functional significance of intermediate coronary narrowings (40% to 70% diameter stenosis) is important for clinical decision making and risk stratification. METHODS In a prospective, multicenter study, SPECT was performed in 191 patients with stable angina and multivessel disease and scheduled for angioplasty (percutaneous transluminal coronary angioplasty, or PTCA) of a severe coronary narrowing. Coronary flow velocity reserve was determined selectively distal to an intermediate lesion in another artery using a Doppler guidewire. Percutaneous transluminal coronary angioplasty of the intermediate lesion was deferred when SPECT was negative or CFVR greater-than-or-equal 2.0. Patients were followed for one year to document major cardiac events (death, infarction, revascularization), related to the intermediate lesion. RESULTS Reversible perfusion defects were documented in the area of the intermediate lesion in 30 (16%) patients; CFVR was positive in 46 (24%) patients. Percutaneous transluminal coronary angioplasty of the intermediate lesion was deferred in 182 patients. During follow-up, 19 events occurred (3 myocardial infarctions, 16 revascularizations). Coronary flow velocity reserve was a more accurate predictor of cardiac events than was SPECT; relative risk: CFVR 3.9 (1.7 to 9.1), p < 0.05; SPECT 0.5 (0.1 to 3.2), p = NS. Multivariate analysis revealed CFVR as the only significant predictor for cardiac events. CONCLUSIONS Deferral of PTCA of intermediate lesions in multivessel disease is safe when CFVR greater-than-or-equal 2.0 (event rate 6%). This selective evaluation of coronary lesion severity during cardiac catheterization allows a more accurate risk stratification than does SPECT, which is important for clinical decision making in this patient cohort.
Collapse
Affiliation(s)
- Steven A J Chamuleau
- Departments of Cardiology, Academic Medical Center-University of Amsterdam, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Chamuleau SAJ, van Eck-Smit BLF, Meuwissen M, Piek JJ. Adequate patient selection for coronary revascularization: an overview of current methods used in daily clinical practice. Int J Cardiovasc Imaging 2002; 18:5-15. [PMID: 12135122 DOI: 10.1023/a:1014372125457] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Widely used non-invasive stress modalities, like exercise ECG, MPS and stress-echocardiography, are the tests of first choice for the diagnosis of CAD. It has been shown in numerous studies that non-invasive assessment of perfusion abnormalities is an adequate strategy for risk stratification. Moreover, non-invasive stress testing should be performed before a diagnostic cardiac catheterization to document the presence of myocardial ischemia, as a prerequisite for coronary revascularization. Coronary angiography is the gold standard for identifying CAD; however this technique is limited in assessing functional severity of coronary narrowings ('illusion of luminology'; see also Figure 5). The recently introduced i.c. hemodynamic parameters (CFVR and FFR) can identify functional severity of specific lesions and have shown a good agreement with the results of non-invasive stress test in validation studies. Furthermore, there is accumulating evidence that it is safe to defer a PTCA procedure, based on normal FFR and CFVR values. As these indices are derived during an invasive cardiac catheterization procedure, its use is recommended during a so called 'ad hoc' PTCA setting. Furthermore, they are particularly useful for clinical decision making in patients with documented multivessel CAD, as both indices allow selective evaluation of coronary narrowings in different arteries. Revascularization procedures are costly and always have a potential risk. It is important to be aware that, using above mentioned methods, unnecessary interventions (lacking potential benefit) may be avoided.
Collapse
Affiliation(s)
- Steven A J Chamuleau
- Department of Cardiology, Academic Medical Center, University of Amsterdam, The Netherlands.
| | | | | | | |
Collapse
|