1
|
Wei M, Yuan Y, Chen D, Pan L, Tong W, Lu W. A systematic review on electrochemical sensors for the detection of acetaminophen. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024. [PMID: 39207184 DOI: 10.1039/d4ay01307g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
Considerable progress has been made in the electrochemical determination of acetaminophen (AP) over the past few decades. Nanomaterials or enzymes as electrode modifiers greatly improve the performance of AP electrochemical sensors. This review focuses on the development potential, detection principles and techniques for the electrochemical analysis of AP. In particular, the design and construction of AP electrochemical sensors are discussed from the perspective of non-enzyme materials (such as nanomaterials, including precious metals, transition metals and non-metals) and enzyme substances (such as aryl acylamidase, polyphenol oxidase and horseradish peroxidase). Moreover, the influencing factors for AP electrochemical sensors and the simultaneous detection of AP and other targets are summarized, and the future prospective of AP electrochemical sensors is outlined. This review provides a reference and guidance for the development and application of electrochemical sensors for AP detection.
Collapse
Affiliation(s)
- Ming Wei
- Kangda College of Nanjing Medical University, Lianyungang 222000, Jiangsu, China.
| | - Yikai Yuan
- Kangda College of Nanjing Medical University, Lianyungang 222000, Jiangsu, China.
| | - Dongsheng Chen
- Kangda College of Nanjing Medical University, Lianyungang 222000, Jiangsu, China.
| | - Lin Pan
- Department of Laboratory Medicine, Tianjin Peace District Obstetrics and Gynecology Hospital, Tianjin, 300020, China
| | - Wenting Tong
- Kangda College of Nanjing Medical University, Lianyungang 222000, Jiangsu, China.
| | - Wenbo Lu
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, Shanxi, China.
| |
Collapse
|
2
|
Amare M. Voltammetric determination of paracetamol in tablet formulation using Fe (III) doped zeolite-graphite composite modified GCE. Heliyon 2019; 5:e01663. [PMID: 31193048 PMCID: PMC6514735 DOI: 10.1016/j.heliyon.2019.e01663] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 03/29/2019] [Accepted: 05/02/2019] [Indexed: 02/05/2023] Open
Abstract
Although paracetamol is known to have excellent safety profile at recommended therapeutic doses, health effects are also reported at acute overdoses. A sensitive and selective voltammetric method using Fe(III) encapsulated zeolite/graphite composite modified glassy carbon electrode is presented in this work for the determination of paracetamol in tablet formulations. In contrast to the unmodified electrode, a fourfold increase of cyclic voltammetric oxidative peak current paralleled by reduced potential difference (ΔE p ) at the modified electrode confirmed electrocatalytic property of the modifier towards oxidation of paracetamol. The oxidative peak current showed linear dependence on concentration range 0.5-200 μM with R 2 and LOD of 0.9989 and 0.01 μM, respectively. The paracetamol content of four brands of tablet samples was found in the range 95.95 ± 0.23-103 ± 0.52% of the theoretical values. Recovery results between 94.54 ± 0.82 and 102 ± 0.34% for spiked paracetamol in tablet samples validated the selectivity of the method for determination of paracetamol in real samples.
Collapse
Affiliation(s)
- Meareg Amare
- Department of Chemistry, Bahir Dar University, Ethiopia
| |
Collapse
|
3
|
Frangu A, Pravcová K, Šilarová P, Arbneshi T, Sýs M. Flow injection tyrosinase biosensor for direct determination of acetaminophen in human urine. Anal Bioanal Chem 2019; 411:2415-2424. [PMID: 30880350 DOI: 10.1007/s00216-019-01687-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 01/14/2019] [Accepted: 02/12/2019] [Indexed: 12/27/2022]
Abstract
An amperometric biosensor compatible with a flow injection analysis (FIA) for highly selective determination of acetaminophen (APAP) in a sample of human urine was developed. This biosensor is also suitable for use in the routine pharmaceutical practice. To prove this statement, two different commercially available pharmaceutical formulations were analyzed. This nano-(bio)electroanalytical device was made from a commercially available screen-printed carbon electrode covered by a thin layer of non-functionalized graphene (NFG) as amperometric transducer. A biorecognition layer was prepared from mushroom (Agaricus bisporus) tyrosinase (EC 1.14.18.1) cross-linked using glutaraldehyde, where resulting aggregates were covered by Nafion®, a known ion exchange membrane. Owing to the use of tyrosinase and presence of NFG, the developed analytical instrument is able to measure even at potentials of 0 V. Linear ranges differ according to choice of detection potential, namely up to 130 μmol L-1 at 0 V, up to 90 μmol L-1 at -0.1 V, and up to 70 μmol L-1 at -0.15 V. The first mentioned linear range is described by the equation Ip [μA] = 0.236 - 0.1984c [μmol L-1] and correlation coefficient r = 0.9987; this equation was used to quantify the content of APAP in each sample. The limit of detection of APAP was estimated to be 1.1 μmol L-1. A recovery of 96.8% (c = 25 μmol L-1, n = 5 measurements) was calculated. The obtained results show that FIA is a very selective method for APAP determination, being comparable to the chosen reference method of reversed-phase high-performance liquid chromatography.
Collapse
Affiliation(s)
- Arbër Frangu
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, University of Prishtina, Str. Mother Teresa, 10 000, Prishtina, Republic of Kosovo
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
| | - Kateřina Pravcová
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
| | - Petra Šilarová
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
| | - Tahir Arbneshi
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, University of Prishtina, Str. Mother Teresa, 10 000, Prishtina, Republic of Kosovo
| | - Milan Sýs
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
| |
Collapse
|
4
|
Hadden JA, Perilla JR. Molecular Dynamics Simulations of Protein-Drug Complexes: A Computational Protocol for Investigating the Interactions of Small-Molecule Therapeutics with Biological Targets and Biosensors. Methods Mol Biol 2018; 1762:245-270. [PMID: 29594776 DOI: 10.1007/978-1-4939-7756-7_13] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
MD simulations provide a powerful tool for the investigation of protein-drug complexes. The following chapter uses the aryl acylamidase-acetaminophen system as an example to describe a general protocol for preparing and running simulations of protein-drug complexes, complete with a step-by-step tutorial. The described approach is broadly applicable toward the study of drug interactions in the context of both biological targets and biosensing enzymes.
Collapse
Affiliation(s)
- Jodi A Hadden
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, USA.
| | - Juan R Perilla
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, USA
| |
Collapse
|
5
|
Asadpour-Zeynali K, Sajjadi SM, Taherzadeh F. Second order advantage obtained by spectroelectrochemistry along with novel carbon nanotube modified mesh electrode: Application for determination of acetaminophen in Novafen samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 153:674-680. [PMID: 26469829 DOI: 10.1016/j.saa.2015.09.035] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 08/22/2015] [Accepted: 09/27/2015] [Indexed: 06/05/2023]
Abstract
A matrix-augmentation multivariate curve resolution-alternating least-squares (MA-MCR-ALS) has been conducted on the spectroelectrochemical data of acetaminophen oxidation in order to quantify acetaminophen in Novafen capsule in the presence of unknown interferences. The experiments were carried out using new cheap mesh electrode, namely carbon nanotube modified mesh electrode (CNMME) as optically transparent thin layer electrode (OTTLE). For each sample, a second order spectroelectrochemical data was obtained and MA-MCR-ALS method was applied to analyze these data. Unlike full trilinear models such as PARAFAC, MCR-ALS is flexible in applying trilinearity constraint for each component, a fact which makes it manage deviations from trilinearity of data effectively. This method was employed in both spectral and kinetic augmentation mode of data under examining different trilinear components. However, spectral augmentation was the only setting which allows MA-MCR-ALS to solve the analytical problem achieving the second order advantage. Therefore, here the results of the augmentation in this mode have been described. In order to obtain the best analytical figures of merit in the analysis, different constraints were investigated. The results indicated the accuracy of the proposed method.
Collapse
Affiliation(s)
- Karim Asadpour-Zeynali
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran.
| | - S Maryam Sajjadi
- Department of Chemistry, Semnan University, Semnan 35195-363, Iran
| | - Fatemeh Taherzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| |
Collapse
|
6
|
Moretti EDS, de Fátima Giarola J, Kuceki M, Prete MC, Pereira AC, Teixeira Tarley CR. A nanocomposite based on multi-walled carbon nanotubes grafted by molecularly imprinted poly(methacrylic acid–hemin) as a peroxidase-like catalyst for biomimetic sensing of acetaminophen. RSC Adv 2016. [DOI: 10.1039/c6ra02150f] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In the present study the synthesis of a nanocomposite based on multi-walled carbon nanotubes grafted by poly(methacrylic acid–hemin) is described.
Collapse
Affiliation(s)
| | - Juliana de Fátima Giarola
- Departamento de Ciências Naturais
- Universidade Federal de São João del Rei (UFSJ)
- Campus Dom Bosco
- São João del Rei
- Brazil
| | - Michele Kuceki
- Universidade Estadual de Londrina (UEL)
- Departamento de Química
- Centro de Ciências Exatas
- Londrina
- Brazil
| | - Maiyara Carolyne Prete
- Universidade Estadual de Londrina (UEL)
- Departamento de Química
- Centro de Ciências Exatas
- Londrina
- Brazil
| | - Arnaldo César Pereira
- Departamento de Ciências Naturais
- Universidade Federal de São João del Rei (UFSJ)
- Campus Dom Bosco
- São João del Rei
- Brazil
| | | |
Collapse
|
7
|
Narang J, Malhotra N, Singh S, Singh G, Pundir CS. Monitoring analgesic drug using sensing method based on nanocomposite. RSC Adv 2015. [DOI: 10.1039/c4ra11255e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
This paper reports a rapid, reliable and sensitive electrochemical method for the determination of acetaminophen, a safe analgesic drug.
Collapse
Affiliation(s)
- Jagriti Narang
- Amity Institute of Nanotechnology
- AMITY University
- Noida
- India
| | | | - Sandeep Singh
- Department of Biochemistry
- M. D. University
- Rohtak-124 001
- India
| | | | - C. S. Pundir
- Department of Biochemistry
- M. D. University
- Rohtak-124 001
- India
| |
Collapse
|
8
|
Calibration of glucose oxidase-based test strips for capillary blood measurement with oxygen saturated venous blood samples. Clin Chim Acta 2013; 415:152-7. [DOI: 10.1016/j.cca.2012.10.033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Revised: 10/15/2012] [Accepted: 10/15/2012] [Indexed: 11/18/2022]
|
9
|
Alonso-Lomillo MA, Domínguez-Renedo O, Román LDTD, Arcos-Martínez MJ. Horseradish peroxidase-screen printed biosensors for determination of Ochratoxin A. Anal Chim Acta 2011; 688:49-53. [DOI: 10.1016/j.aca.2011.01.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Revised: 12/10/2010] [Accepted: 01/04/2011] [Indexed: 10/18/2022]
|
10
|
Development of an acetaminophen amperometric biosensor based on peroxidase entrapped in polyacrylamide microgels. Biosens Bioelectron 2011; 26:1883-9. [DOI: 10.1016/j.bios.2010.03.024] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2009] [Revised: 03/18/2010] [Accepted: 03/18/2010] [Indexed: 11/20/2022]
|
11
|
Abstract
Given the increasing demand for practical and low-cost analytical techniques, biosensors have attracted attention for use in the quality analysis of drugs, medicines, and other analytes of interest in the pharmaceutical area. Biosensors allow quantification not only of the active component in pharmaceutical formulations, but also the analysis of degradation products and metabolites in biological fluids. Thus, this article presents a brief review of biosensor use in pharmaceutical analysis, focusing on enzymatic electrochemical sensors.
Collapse
|
12
|
Saraswathyamma B, Pająk M, Radecki J, Maes W, Dehaen W, Girish Kumar K, Radecka H. PVC Supported Liquid Membrane and Carbon Paste Potentiometric Sensors Incorporating a Mn(III)-Porphyrin for the Direct Determination of Undissociated Paracetamol. ELECTROANAL 2008. [DOI: 10.1002/elan.200804280] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
13
|
Felix FS, Brett CMA, Angnes L. Carbon film resistor electrode for amperometric determination of acetaminophen in pharmaceutical formulations. J Pharm Biomed Anal 2007; 43:1622-7. [PMID: 17215098 DOI: 10.1016/j.jpba.2006.11.038] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2006] [Revised: 11/22/2006] [Accepted: 11/29/2006] [Indexed: 10/23/2022]
Abstract
Flow injection analysis (FIA) with amperometric detection was employed for acetaminophen quantification in pharmaceutical formulations using a carbon film resistor electrode. This sensor exhibited sharp and reproducible current peaks for acetaminophen without chemical modification of its surface. A wide linear working range (8.0x10(-7) to 5.0x10(-4) mol L(-1)) in phosphate buffer solution as well as high sensitivity (0.143 A mol(-1) L cm(-2)) and low submicromolar detection limit (1.36x10(-7) mol L(-1)) were achieved. The repeatability (R.S.D. for 10 successive injections of 5.0x10(-6) and 5.0x10(-5) mol L(-1) acetaminophen solutions) was 3.1 and 1.3%, respectively, without any memory effect between injections. The new procedure was applied to the analyses of commercial pharmaceutical products and the results were in good agreement with those obtained utilizing a spectrophotometric method. Consequently, this amperometric method has been shown to be very suitable for quality control analyses and other applications with similar requirements.
Collapse
Affiliation(s)
- Fabiana S Felix
- Instituto de Química, Universidade de São Paulo, CP 26077, 05599-970 São Paulo, Brazil
| | | | | |
Collapse
|
14
|
Yu D, Renedo O, Blankert B, Sima V, Sandulescu R, Arcos J, Kauffmann JM. A Peroxidase-Based Biosensor Supported by Nanoporous Magnetic Silica Microparticles for Acetaminophen Biotransformation and Inhibition Studies. ELECTROANAL 2006. [DOI: 10.1002/elan.200603579] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Espinosa Bosch M, Ruiz Sánchez AJ, Sánchez Rojas F, Bosch Ojeda C. Determination of paracetamol: historical evolution. J Pharm Biomed Anal 2006; 42:291-321. [PMID: 16716555 DOI: 10.1016/j.jpba.2006.04.007] [Citation(s) in RCA: 126] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2006] [Revised: 04/03/2006] [Accepted: 04/10/2006] [Indexed: 10/24/2022]
Abstract
Paracetamol is a common analgesic and antipyretic drug that is used for the relief of fever, headaches and other minor aches and pains. Their determination in pharmaceuticals is of paramount importance, since an overdose of paracetamol can cause fulminating hepatic necrosis and other toxic effects. Many analytical methodologies have been proposed for the determination of paracetamol. The aim of the present study is to evaluate the utility of different techniques for quantification of paracetamol content in pharmaceutical formulations and biological samples.
Collapse
Affiliation(s)
- M Espinosa Bosch
- Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, Campus Teatinos, 29071 Málaga, Spain
| | | | | | | |
Collapse
|
16
|
Wang C, Hu X, Leng Z, Yang G, Jin G. DIFFERENTIAL PULSE VOLTAMMETRY FOR DETERMINATION OF PARACETAMOL AT A PUMICE MIXED CARBON PASTE ELECTRODE. ANAL LETT 2001. [DOI: 10.1081/al-100108420] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
17
|
Fiaccabrino G, Tang XM, Skinner N, De Rooij N, Koudelka-Hep M. Electrochemical characterization of thin-film carbon interdigitated electrode arrays. Anal Chim Acta 1996. [DOI: 10.1016/0003-2670(96)00068-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
18
|
Christie I, Leeds S, Baker M, Keedy F, Vadgama P. Direct electrochemical determination of paracetamol in plasma. Anal Chim Acta 1993. [DOI: 10.1016/0003-2670(93)80386-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|