1
|
Kjærgaard K, Yilmaz S, Kaptein B, Overgaard S, Ding M. Measuring total hip arthroplasty liner wear using the EOS Imaging System: experimental and clinical results. Acta Orthop 2024; 95:530-535. [PMID: 39268932 PMCID: PMC11395818 DOI: 10.2340/17453674.2024.41912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Indexed: 09/15/2024] Open
Abstract
BACKGROUND AND PURPOSE The low-dose EOS Imaging System is an emerging tool for 3-dimensional measurements in orthopedics. The clinical feasibility for measuring total hip arthroplasty (THA) liner wear has not yet been investigated. We aimed to evaluate the feasibility of using EOS to measure THA liner wear by examining the experimental accuracy using a THA phantom and clinical precision of patients with THA, considering a clinically relevant precision at the 95% repeatability limit to be 0.2 mm. METHODS An experimental THA phantom with movable stem and a fixed cup with a plastic liner was constructed to simulate progressive 3D liner wear. Series of 11 pairs of radiographs with 50 μm femoral movement in between were obtained for each 3D axis in EOS. 30 patients with a THA were scanned twice using EOS to assess precision. Model-based radiostereometric analysis (RSA) was used for wear measurement. RESULTS The mean difference (true minus simulated wear) with standard deviation (SD) and 95% limits of agreement for experimental THA wear were 0.005 (0.037) and [-0.069 to 0.079] mm for the vertical (y) axis. The mean (SD) and 95% repeatability limit for precision for clinical measurement were -0.029 (0.105) and 0.218 mm. CONCLUSION Experimental THA liner wear using EOS was within clinically relevant tolerances and without bias. The clinical precision was just outside our defined clinically relevant precision. Compared with conventional RSA, EOS is less accurate and precise but may still be of value for certain clinical applications, provided larger sample size or longer follow-up are available.
Collapse
Affiliation(s)
- Kristian Kjærgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Sibel Yilmaz
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Bart Kaptein
- Biomechanics and Imaging Group, Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Søren Overgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense; Department of Clinical Research, University of Southern Denmark, Odense; Copenhagen University Hospital, Bispebjerg Department of Orthopaedic Surgery and Traumatology, Frederiksberg Hospital, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Ming Ding
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
2
|
Zaribaf FP, Koster LA, Kaptein BL, Pegg EC, Gill HS. Model-based Roentgen Stereophotogrammetric Analysis (RSA) of polyethylene implants. Med Eng Phys 2024; 130:104201. [PMID: 39160015 DOI: 10.1016/j.medengphy.2024.104201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/11/2024] [Accepted: 06/27/2024] [Indexed: 08/21/2024]
Abstract
Model-based Roentgen Stereophotogrammetric Analysis (RSA) is able to measure the migration of metallic prostheses with submillimeter accuracy through contour-detection and 3D surface model matching techniques. However, contour-detection is only possible if the prosthesis is clearly visible in the radiograph; consequently Model-based RSA cannot be directly used for polymeric materials due to their limited X-ray attenuation; this is especially clinically relevant for all-polyethylene implants. In this study the radiopacity of unicompartmental Ultra-High Molecular Weight Polyethylene (UHMWPE) knee bearings was increased by diffusing an oil-based contrast agent into the surface to create three different levels of surface radiopacity. Model-based RSA was performed on the bearings alone, the bearings alongside a metallic component held in position using a phantom, the bearings cemented into a Sawbone tibia, and the bearings at different distances from the femoral component. For each condition the precision and accuracy of zero motion of Model-based RSA were assessed. The radiopaque bearings could be located in the stereo-radiographs using Model-based RSA an accuracy comparable to metallic parts for translational movements (0.03 mm to 0.50 mm). For rotational movements, the accuracy was lower (0.1∘ to 3.0∘). The measurement accuracy was compared for all the radiopacity levels and no significant difference was found (p=0.08). This study demonstrates that contrast enhanced radiopaque polyethylene can be used for Model-based RSA studies and has equivalent translational measurement precision to metallic parts in the superior-inferior direction.
Collapse
Affiliation(s)
- F P Zaribaf
- Centre for Therapeutic Innovation and Department of Mechanical Engineering, University of Bath, Bath, UK
| | - L A Koster
- Department of Orthopaedics Leiden University Medical Center, Leiden, Netherlands
| | - B L Kaptein
- Department of Orthopaedics Leiden University Medical Center, Leiden, Netherlands
| | - E C Pegg
- Centre for Therapeutic Innovation and Department of Mechanical Engineering, University of Bath, Bath, UK.
| | - H S Gill
- Centre for Therapeutic Innovation and Department of Mechanical Engineering, University of Bath, Bath, UK
| |
Collapse
|
3
|
Kaptein BL, Pijls B, Koster L, Kärrholm J, Hull M, Niesen A, Heesterbeek P, Callary S, Teeter M, Gascoyne T, Röhrl SM, Flivik G, Bragonzoni L, Laende E, Sandberg O, Solomon LB, Nelissen R, Stilling M. Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations. Acta Orthop 2024; 95:256-267. [PMID: 38819193 PMCID: PMC11141406 DOI: 10.2340/17453674.2024.40709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/08/2024] [Indexed: 06/01/2024] Open
Abstract
Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands.
| | - Bart Pijls
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Lennard Koster
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Johan Kärrholm
- Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maury Hull
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Abby Niesen
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Petra Heesterbeek
- Orthopedic Research Department, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Stuart Callary
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Matthew Teeter
- Department of Medical Biophysics, Western University, London, Canada
| | | | - Stephan M Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Gunnar Flivik
- Department of Orthopedics, Skane University Hospital, Lund, Sweden
| | | | - Elise Laende
- Department of Surgery, Dalhousie University, Halifax, Canada
| | | | - L Bogdan Solomon
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Rob Nelissen
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Maiken Stilling
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
4
|
Cao H, Zheng T, Jin Z. Validation for the effect of intra-exposure patient motion on the assessment of radiostereometric implant migration in a tibial component phantom study. Orthop Traumatol Surg Res 2024; 110:103776. [PMID: 38016580 DOI: 10.1016/j.otsr.2023.103776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/06/2023] [Accepted: 11/23/2023] [Indexed: 11/30/2023]
Abstract
BACKGROUND An increasing number of radiostereometry (RSA) research studies have long-term follow-up implant migration outcomes, which show ascending curves of implant migration with occasionally decreasing migration. After scrutinizing images and RSA scenes related to the alternating curves, we suppose that intra-exposure patient motion may contribute to that. The main purposes of this in vitro study were 1) to identify whether the patient motion in different directions could result in the inaccurate assessment of implant migration, and 2) to figure out which direction(s) accounted for the alternating curves. HYPOTHESIS It was hypothesized that the assessments of implant migration would be less precise and accurate than they could be when patient motion occurred, and such motion would contribute to the alternating curves of radiostereometric implant migration. MATERIALS AND METHODS A customized phantom, assembled with a tibial component, was designed for simulating intra-exposure patient motion during follow-up RSA examinations. Two different Roentgen tubes were used as the current standard of radiology departments. Radiographs were acquired in a uniplanar technical arrangement. Two defined protocols were conducted: one is to simulate implant migration outcomes at post-op, the early stage (6months), and the later stage (2 to 10years) ; during the later stage, the other is to mimic patient motion by phantom motion in the medial-lateral (x), distal-proximal (y), and anterior-posterior (z) axes. RESULTS Phantom motion could result in the inaccurate assessment of implant migration, and translations along the medial-lateral (x) axis were the most influenced by patient motion. Motion along the medial-lateral (x) axis could account for the curves with decreasing migration. DISCUSSION Our assessments of implant migration may be less precise and accurate than they could be when intra-exposure patient motion occurs. We probably neglect the importance of 100% simultaneous exposures, and the influence of patient motion on RSA accuracy and data reliability, due to the difficulty in detecting patient (micro)motion. Electronically synchronized exposures of two paired Roentgen tubes are 100% simultaneous for image acquisition, and they are thus highly recommended for the assessment of implant migration in RSA. TYPE OF STUDY AND LEVEL OF PROOF not applicable.
Collapse
Affiliation(s)
- Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany; Department of Orthopaedic Surgery, Taizhou Second People's Hospital, 225599 Taizhou, PR China.
| | - Tiansheng Zheng
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Gannan Medical University, 341000 Ganzhou, PR China
| | - Zhengshuai Jin
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Nanjing Medical University, 210029 Nanjing, PR China; Department of Orthopaedic Surgery, Jiangsu Shengze Hospital, 215228 Suzhou, PR China
| |
Collapse
|
5
|
Niesen AE, Tirumalai PA, Howell SM, Hull ML. Risk of tibial baseplate loosening is low in patients following unrestricted kinematic alignment total knee arthroplasty using a cruciate-retaining medial conforming insert: A study using radiostereometric analysis at 2 years. Knee Surg Sports Traumatol Arthrosc 2024; 32:693-703. [PMID: 38415963 DOI: 10.1002/ksa.12089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/17/2024] [Accepted: 01/18/2024] [Indexed: 02/29/2024]
Abstract
PURPOSE Assessing the risk of tibial baseplate loosening in patients after unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) using a medially conforming insert is important because baseplates generally are aligned in varus which has been linked to an increased incidence of aseptic loosening following mechanically aligned TKA. Two limits that indicate long-term stability in patients are a change in maximum total point motion between 1 and 2 years (ΔMTPM) < 0.2 mm and anterior tilt at 2 years < 0.8°. The purposes were to determine: (1) the number of patients with ΔMTPM > 0.2 mm, (2) the number of patients with anterior tilt > 0.8° and (3) whether increased varus baseplate and limb alignment were associated with increased migration. METHODS Thirty-five patients underwent cemented, caliper-verified, unKA TKA using a medially conforming tibial insert with posterior cruciate ligament (PCL) retention. Biplanar radiographs acquired on the day of surgery and at 1.5, 3, 6, 12 and 24 months were processed with model-based radiostereometric analysis (RSA) software to determine migration and the number of patients with migration above the two stability limits. Medial proximal tibial angle (MPTA), hip-knee-ankle angle (HKAA) and posterior slope angle (PSA) were analyzed for an association with migration in six degrees of freedom and in MTPM. RESULTS Thirty-two of 35 patients were available for analysis at 2 years. One patient exhibited ΔMTPM > 0.2 mm. The same patient exhibited anterior tilt > 0.8°. Varus rotation (p = 0.048, r ≤ 0.34) and medial translation (p = 0.0273, r ≤ 0.29) increased with increased varus baseplate alignment. CONCLUSION The results indicate low risk of long-term baseplate loosening in patients. Although varus rotation and medial translation increased with increased varus baseplate alignment, the magnitudes of the migrations were minimal and did not increase ΔMTPM and anterior tilt. LEVEL OF EVIDENCE Level II, therapeutic prospective cohort study.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, California, USA
| | - Pranav A Tirumalai
- Department of Biomedical Engineering, University of California, Davis, California, USA
| | - Stephen M Howell
- Department of Biomedical Engineering, University of California, Davis, California, USA
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, California, USA
- Department of Mechanical Engineering, University of California, Davis, California, USA
- Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, California, USA
| |
Collapse
|
6
|
Bendtsen MAF, Odgaard A, Madsen F, Mosegaard SB, Thomsen JS, Hauge EM, Søballe K, Stilling M. Preoperative proximal tibial bone density, bone microarchitecture, and bone turnover are not associated with postoperative tibial component migration in cemented and cementless medial unicompartmental knee replacements: secondary analyses from a randomized controlled trial. Acta Orthop 2024; 95:121-129. [PMID: 38391197 PMCID: PMC10885816 DOI: 10.2340/17453674.2024.39917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 11/16/2023] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND AND PURPOSE Cementless arthroplasty fixation relies on early bone ingrowth and may be poor in patients with low proximal tibial bone density or abnormal bone turnover. We aimed first to describe the baseline bone properties in patients undergoing medial unicompartmental knee replacement (UKR), and second to investigate its association with cemented and cementless tibial component migration until 2 years. METHODS A subset investigation of 2 patient groups from a 3-armed randomized controlled trial was conducted. There were 26 cemented and 25 cementless medial UKRs with twin-pegged femoral components. Volumetric bone mineral density (vBMD) and microstructure of the excised medial tibial plateau were ascertained with µCT. Bone turnover was estimated using dynamic histomorphometry (eroded surface/bone surface = ES/BS, osteoid surface/bone surface = OS/BS, mineralizing surface/bone surface = MS/BS). Tibial component migration in 4 feature points was followed for 2 years with radiostereometry. RESULTS At the 2-year follow-up, the cementless tibial components migrated 0.38 mm (95% confidence interval [CI] 0.14-0.62) total translation more than the cemented components at the posterior feature point. The greatest migration in the cementless group was subsidence at the posterior feature point of 0.66 mm (CI 0.48-0.84) until 6 weeks, and from 3 months the components were stable. Cemented tibial components subsided very little. Between 1- and 2-year follow-ups, no cementless but 4 cemented tibial components revealed continuous migration. OS/BS was half of the ES/BS. No µCT or histomorphometric parameters showed any clinically relevant correlation with tibial component migration at the posterior feature point for either cemented or cementless UKR at 6 weeks' or 2 years' follow-up after adjustment for age, BMI, and sex. CONCLUSION Preoperative vBMD, bone turnover, and microstructure were not associated with postoperative tibial component migration of cemented and cementless medial UKR.
Collapse
Affiliation(s)
- Mathias Alrø Fichtner Bendtsen
- Department of Clinical Medicine, Aarhus University, Aarhus; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus.
| | - Anders Odgaard
- Department of Orthopaedic Surgery, Rigshospitalet-Copenhagen University Hospital, Copenhagen; Department of Clinical Medicine, University of Copenhagen, Copenhagen
| | - Frank Madsen
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus
| | | | | | | | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus; Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus
| | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus; Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus
| |
Collapse
|
7
|
Mosegaard SB, Odgaard A, Madsen F, Rømer L, Kristensen PW, Vind TD, Søballe K, Stilling M. Comparison of cementless twin-peg, cemented twin-peg and cemented single-peg femoral component migration after medial unicompartmental knee replacement: a 5-year randomized RSA study. Arch Orthop Trauma Surg 2023; 143:7169-7183. [PMID: 37568057 PMCID: PMC10635966 DOI: 10.1007/s00402-023-04991-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 07/10/2023] [Indexed: 08/13/2023]
Abstract
BACKGROUND The component design and fixation method of joint arthroplasty may affect component migration and survival. The aim of this study was to compare fixation of cementless twin-peg (CLTP), cemented twin-peg (CTP) and cemented single-peg (CSP) femoral components of medial unicompartmental knee replacement (UKR). METHODS Eighty patients (mean age = 63 years, 48 males) with medial knee osteoarthritis were randomized in three ways to CLTP (n = 25), CTP (n = 26) or CSP (n = 29) femoral UKR components. The patients were followed 5 years postoperatively with RSA, bone mineral density (BMD), PROMs and radiological evaluation of radiolucent lines (RLL), femoral component flexion angle and complications. RESULTS At the 5-year follow-up, femoral component total translation was comparable between the three groups (p = 0.60). Femoral component internal rotation was 0.50° (95% CI 0.3; 0.69) for the CLTP group, 0.58° (95% CI 0.38; 0.77) for the CTP group and 0.25° (95% CI 0.07; 0.43) for the CSP group (p = 0.01). BMD decreased peri-prosthetically (range - 11.5%; - 14.0%) until 6-month follow-up and increased toward the 5-year follow-up (range - 3.6%; - 5.8%). BMD change did not correlate with component migration. Lower flexion angle was correlated with higher 5-year subsidence, total translation, varus rotation and maximum total point motion (p = 0.01). Two patients (1 CLTP, 1 CTP) had RLL in the posterior zone. There were two revisions. CONCLUSION At 5-year follow-up, fixation of UKA femoral components with twin-peg was not superior to the single-peg design. Cementless and cemented twin-peg femoral components had similar fixation. A lower flexion angle was correlated with higher component migration.
Collapse
Affiliation(s)
- Sebastian Breddam Mosegaard
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, Denmark
| | - Anders Odgaard
- Department of Orthopaedic Surgery, Rigshospitalet, Copenhagen University Hospital, Blegdamsvej 9, 2100, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200, Copenhagen N, Denmark
| | - Frank Madsen
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Per Wagner Kristensen
- Department of Orthopaedic Surgery, Vejle Hospital, Beriderbakken 4, 7100, Vejle, Denmark
| | - Tobias Dahl Vind
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Kjeld Søballe
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Maiken Stilling
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, Denmark.
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
| |
Collapse
|
8
|
Niesen AE, Hull ML. State of the Art in Radiostereometric Analysis for Tibial Baseplate Migration and Future Research Directions. J Biomech Eng 2023; 145:120801. [PMID: 37792485 DOI: 10.1115/1.4063626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 09/25/2023] [Indexed: 10/06/2023]
Abstract
Radiostereometric analysis (RSA) measures movement (migration) of a baseplate relative to the underlying tibia after total knee arthroplasty (TKA) and has been used extensively to evaluate safety of new implant designs and/or surgical techniques regarding baseplate loosening. Because RSA is a complex methodology which involves various choices that researchers make, including whether to use marker-based or model-based methods, which migration metric to report, how to relate short-term migrations to long-term risk, and how these choices impact error, the objectives of this review were to: (1) lay out a comprehensive structure illustrating the multiple components/considerations for RSA and their interrelations, (2) review components of the structure using the latest RSA literature, and (3) use the preceding review as a context for identifying future areas of study. The components to be reviewed were structured using the following topics: type of RSA, migration metrics, sources of error, studies/reports of error, stability limits, and studies of error in stability limits. Based on the current RSA literature and knowledge gaps which exist, the following future research directions were identified: (1) revising the ISO standard to require reporting of clinical measurement error (bias) and recommending use of a local baseplate coordinate system, (2) identifying the migration metric and associated threshold most predictive of baseplate loosening for individual patients, (3) creating a method for data sharing to improve individual patient diagnostics, and (4) determining an appropriate stability limit for model-based RSA for group stability and individual patient diagnostics.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616; Department of Mechanical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA 95817
| |
Collapse
|
9
|
Øhrn FD, Engseth LHW, Pripp AH, Röhrl SMH, Schulz A. Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver. Acta Orthop 2023; 94:550-544. [PMID: 37909103 PMCID: PMC10618912 DOI: 10.2340/17453674.2023.24022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 10/08/2023] [Indexed: 11/02/2023] Open
Abstract
BACKGROUND AND PURPOSE Radiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. MATERIAL AND METHODS We performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal. RESULTS Low dose (mean 0.07, 95% confidence interval [CI] 0.06-0.08) and standard dose CT-RSA (0.08, CI 0.07-0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00-0.02 mm. The F-statistic (0.99, CI 0.63-1.55) and sdtest (1.05, CI 0.43-2.58) also supported this. CONCLUSION We conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.
Collapse
Affiliation(s)
- Frank-David Øhrn
- Orthopaedic Department, Kristiansund Hospital, Møre and Romsdal Hospital Trust, Kristiansund; Faculty of Medicine and Health Sciences, Department of Neuromedicine and Movement Science (INB), NTNU Norwegian University of Science and Technology.
| | - Lars H W Engseth
- Division of Orthopaedic Surgery, Oslo University Hospital Ullevål, Oslo; Faculty of Medicine, University of Oslo, Oslo
| | - Are H Pripp
- Oslo Centre for Biostatistics and Epidemiology, Oslo University Hospital, Oslo
| | - Stephan M H Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital Ullevål, Oslo; Faculty of Medicine, University of Oslo, Oslo
| | - Anselm Schulz
- Department of Radiology and Nuclear Medicine, Oslo University Hospital Ullevål, Oslo, Norway
| |
Collapse
|
10
|
Jørgensen PB, Krag-Nielsen N, Lindgren L, Mørup RMS, Kaptein B, Stilling M. Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography. Arch Orthop Trauma Surg 2023; 143:5919-5926. [PMID: 36422666 DOI: 10.1007/s00402-022-04674-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 10/23/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. METHODS RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arcoma T0 with ST-VI image plates and Profect CR-IR 363 reader to (2) AdoraRSA with CXDI-70C wireless DR detectors in a clinical uniplanar RSA set-up with a ± 20 degrees tube angulation and 35 cm × 43 cm detectors. Effective dose was calculated using dedicated software. Image quality was evaluated using calibration errors as calculated by the RSA software. RESULTS The mean dose for hips was 0.14 (SD 0.04) mSv in the CR system and 0.05 (SD 0.02) mSv in the DR system. The mean dose for shoulders was 0.16 (SD 0.07) mSv in the CR system and 0.09 (SD 0.03) mSv in the DR system. Radiation dose was 64% (p < 0.001) and 43% (p = 0.03) lower in the DR system compared with the CR system for hip and shoulder RSA, respectively. Image quality was better for the DR system with 60-80% less calibration errors compared to the CR system. CONCLUSION Owing to highly efficient detectors and added filtration at the x-ray tubes, the DR system considerably reduced radiation dose compared with the CR system without compromising image quality. Based on the findings in this study, we recommend replacing CR RSA systems with DR RSA systems. REGISTRATION Patients were selected from clinical studies performed on the two systems and approved by the local ethics committee [20060165, M-20100112, M-20070082, M-20110224, and 20070258] and registered with ClinicalTrials.gov [NCT00408096, NCT01289834, NCT00913679, NCT02311179, and NCT00679120].
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark.
| | | | - Lars Lindgren
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Rikke Margrethe Staghøj Mørup
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark
| | - Bart Kaptein
- Biomechanics and Imaging Group (BIG), Leiden University Medical Center, Leiden, The Netherlands
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark
| |
Collapse
|
11
|
Correlating Contact Kinematics to Tibial Component Migration Following Cemented Bicruciate Stabilized Total Knee Arthroplasty. J Arthroplasty 2023; 38:S355-S362. [PMID: 36758840 DOI: 10.1016/j.arth.2023.01.051] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 01/23/2023] [Accepted: 01/31/2023] [Indexed: 02/11/2023] Open
Abstract
BACKGROUND Contact kinematics in total knee arthroplasty (TKA) has been shown to affect tibial component migration. However, previous studies correlating kinematic variables to implant migration were completed with older TKA designs. The goal of this study was to determine if there are associations between contact kinematics and tibial component migration for a cemented, bicruciate stabilized (BCS) TKA system. METHODS A total of 54 knees implanted with a BCS TKA system were analyzed using radiostereometric analysis (RSA). Patients underwent RSA exams at 2 weeks, 6 weeks, 3 months, 6 months, 1 year, and 2 years post operation to measure tibial component migration. At 1 year, contact kinematics was evaluated during a quasi-static deep knee bend. Linear regression analyses were performed between kinematic variables and migration values. RESULTS Significant correlations were found between contact kinematics and tibial component migration. Excursion on the lateral condyle was the most consistent variable correlating with implant migration. Six patients had > 0.2 mm migrations from 1 to 2 years post operation indicating continuously migrating tibial components, and most had atypical contact kinematics. CONCLUSION Kinematics was shown to influence tibial component migration. Reduced lateral excursion, suggesting a more constrained lateral condyle, resulted in greater implant migration. The 6 patients who had continuously migrating tibial components had demographic factors that may limit the ability to endure unintended force transmissions caused by abnormal kinematics. These results highlight the importance of restoring knee kinematics with this BCS TKA design to minimize improper force transmissions and resultant increased implant migrations.
Collapse
|
12
|
Petersen ET, Vind TD, Jürgens-Lahnstein JH, Christensen R, de Raedt S, Brüel A, Rytter S, Andersen MS, Stilling M. Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model. J Orthop Res 2023; 41:436-446. [PMID: 35532010 PMCID: PMC10084430 DOI: 10.1002/jor.25359] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/28/2022] [Accepted: 05/05/2022] [Indexed: 02/04/2023]
Abstract
Radiostereometic analysis (RSA) is an accurate method for rigid body pose (position and orientation) in three-dimensional space. Traditionally, RSA is based on insertion of periprosthetic tantalum markers and manual implant contour selection which limit clinically application. We propose an automated image registration technique utilizing digitally reconstructed radiographs (DRR) of computed tomography (CT) volumetric bone models (autorsa-bone) as a substitute for tantalum markers. Furthermore, an automated synthetic volumetric representation of total knee arthroplasty implant models (autorsa-volume) to improve previous silhouette-projection methods (autorsa-surface). As reference, we investigated the accuracy of implanted tantalum markers (marker) or a conventional manually contour-based method (mbrsa) for the femur and tibia. The data are presented as mean (standard deviation). The autorsa-bone method displayed similar accuracy of -0.013 (0.075) mm compared to the gold standard method (marker) of -0.013 (0.085). The autorsa-volume with 0.034 (0.106) mm did not markedly improve the autorsa-surface with 0.002 (0.129) mm, and none of these reached the mbrsa method of -0.009 (0.094) mm. In conclusion, marker-free RSA is feasible with similar accuracy as gold standard utilizing DRR and CT obtained volumetric bone models. Furthermore, utilizing synthetic generated volumetric implant models could not improve the silhouette-based method. However, with a slight loss of accuracy the autorsa methods provide a feasible automated alternative to the semi-automated method.
Collapse
Affiliation(s)
- Emil Toft Petersen
- University Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Tobias Dahl Vind
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Jonathan Hugo Jürgens-Lahnstein
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Rasmus Christensen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Sepp de Raedt
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Annemarie Brüel
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
| | - Søren Rytter
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | | | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
13
|
Cao H, Sesselmann S, Xu J, Seehaus F, Forst R. How Do Classic (Static) RSA and Patient Motion Artifacts Affect the Assessment of Migration of a TKA Tibial Component? An In Vitro Study. Clin Orthop Relat Res 2023; 481:400-412. [PMID: 36398327 PMCID: PMC9831201 DOI: 10.1097/corr.0000000000002453] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 09/21/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND Classic (static) Roentgen stereophotogrammetric analysis (RSA) is the current gold standard to assess, in vivo, the migration of total joint arthroplasty components. To prevent potential patient motion artifacts during the acquisition of paired radiostereometric images, images must be taken by simultaneously firing both X-ray tubes. However, the influence of nonsynchronized RSA paired images or patient motion artifacts on the precision of RSA and the assessment of implant migration is not well understood. QUESTIONS/PURPOSES We assessed (1) the effect of possible patient motion on the precision of RSA and (2) apparent differences in implant migration among axes (in-plane and out-of-plane translations and in-plane and out-of-plane rotations) of possible motion artifacts. METHODS Radiographs of two tibial knee arthroplasty components, each fixed in two bone-implant models as a customized phantom, were taken in a uniplanar measurement setup. We evaluated both model-based (implant models from reversed engineering) and marker-based (additional attached implant markers) RSA approaches. Between the simulated reference and follow-up examinations, we used one of the bone-implant models to simulate patient motion and the other to simulate no patient motion in parallel. Two defined protocols were followed for each of the bone-implant models: no-motion and simulated motion protocols. RSA image pairs were analyzed using a model-based RSA software package (MBRSA 4.1, RSA core ). Precision was calculated through repeat examinations, and migration of the two components was assessed for comparison of the components with each other. Measurements were taken along the medial-lateral and posterior-anterior axes for translations and around the cranial-caudal axis for rotations. The maximum total point motion was measured for comparison between the two components. RESULTS The effect of simulated patient motion was generally small, except in the cranial-caudal axis, but the induced imprecision associated with motion was larger in model-based RSA than it was in marker-based RSA. The mean ± standard deviation values of precision in model-based RSA were 0.035 ± 0.015 mm, 0.045 ± 0.014 mm, and 0.049 ± 0.036 mm greater than those in marker-based RSA, in accordance with the simulated motion protocol in translations along the medial-lateral axis (0.018 ± 0.004 mm; p = 0.01), along the posterior-anterior axis (0.018 ± 0.007 mm; p = 0.003), and rotations around the cranial-caudal axis (0.017 ± 0.006 mm; p = 0.02). Apparent differences in implant migration were the greatest for the maximum total point motion. The maximum total point motion increased from 0.038 ± 0.007 mm for the no-motion protocol to 1.684 ± 0.038 mm (p < 0.001) for the simulated motion protocol in marker-based RSA, and from 0.101 ± 0.027 mm for the no-motion protocol to 1.973 ± 0.442 mm (p < 0.001) for the simulated motion protocol in model-based RSA, and was the worst-case scenario regarding patient motion artifacts. CONCLUSION Patient motion exceeding 1 mm or 1° on nonsynchronized RSA images affects measurement errors regarding the detection of migration of a tibial component. In clinical RSA studies, the effect of patient motion on the assessment of implant migration should be of particular concern, even if clinical RSA systems have acceptable precision. Specially trained radiographers are crucial for correctly acquiring radiographs, especially when simultaneous radiography exposures are not electronically automated. In general, RSA requires synchronized image acquisition, and this should be the state-of-the-art. CLINICAL RELEVANCE In clinical RSA studies, precision assessed by repeat examinations may not be reliable using the current standards that are widely used in radiology departments. When assessing implant migration for reliability, comparison of the maximum total point motion between the tested (simulated motion) implant and baseline (no-motion) implant, as in this study, is advocated because of the accurate detection of patient motion artifacts.
Collapse
Affiliation(s)
- Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Department of Orthopaedic Surgery, Taizhou Second People’s Hospital, Taizhou, PR China
| | - Stefan Sesselmann
- Institute for Medical Technology, Ostbayerische Technische Hochschule Amberg-Weiden, Weiden, Germany
| | - Jing Xu
- Department of Orthopaedic Surgery, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, PR China
| | - Frank Seehaus
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Department of Orthopaedic and Trauma Surgery, University Hospital Erlangen, Erlangen, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
14
|
Koster LA, Rassir R, Kaptein BL, Sierevelt IN, Schager M, Nelissen RGHH, Nolte PA. A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty. Bone Joint J 2023; 105-B:148-157. [PMID: 36722052 DOI: 10.1302/0301-620x.105b2.bjj-2022-0414.r1] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
AIMS The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs. METHODS A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses. RESULTS The mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group. CONCLUSION The mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected.Cite this article: Bone Joint J 2023;105-B(2):148-157.
Collapse
Affiliation(s)
- Lennard A Koster
- Department of Orthopaedics, Leiden Universitair Medisch Centrum, Leiden, Netherlands
| | - Rachid Rassir
- Department of Orthopaedics, Spaarne Gasthuis Hoofddorp, Hoofddorp, Netherlands
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden Universitair Medisch Centrum, Leiden, Netherlands
| | - Inger N Sierevelt
- SCORE, Specialized Centre of Orthopedic Research and Education, Xpert Orthopedie Amsterdam, Amsterdam, Netherlands
| | - Marjolein Schager
- Department of Orthopaedics, Spaarne Gasthuis Hoofddorp, Hoofddorp, Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden Universitair Medisch Centrum, Leiden, Netherlands
| | - Peter A Nolte
- Department of Orthopaedics, Spaarne Gasthuis Hoofddorp, Hoofddorp, Netherlands
| |
Collapse
|
15
|
Cao H. Accuracy of radiostereometric analysis using a motorized Roentgen system in a pilot study for clinical simulation. Med Eng Phys 2023; 111:103929. [PMID: 36792244 DOI: 10.1016/j.medengphy.2022.103929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 10/26/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022]
Abstract
Radiostereometric analysis (RSA) is routinely implemented with two paired Roentgen tubes for three-dimensional (3D) implant migration measurements. A conventional set-up of one stationary tube and one mobile could be time-consuming. Utilizing two customized ceiling-mounted tubes is normally associated with investment costs. Thus, a pilot set-up of a motorized system (single Roentgen source) for radiostereometric image acquisition may be a time-saving and space-efficient alternative. RSA using the motorized system is feasible in this study as a non-synchronized image acquisition technique, however, patient motion may occur and influence the assessment of implant migration. The phantom study aimed to assess accuracy of RSA using the motorized Roentgen system in this in vitro study. Accuracy values of translations and rotations were ±0.29 mm and ±0.48° for the single Roentgen source RSA set-up and ±0.26 mm and ±0.48° for the conventional RSA set-up. This study was also performed to simulate potential patient motion during exposure intervals between paired image acquisition. RSA using the motorized system is able to implement RSA with acceptable accuracy. In general, RSA with synchronized image acquisition is the gold standard to access in vivo implant migration with the highest accuracy. Patient motion exists in non-synchronized image acquisition techniques and results in RSA-related motion artifacts. Then we introduced what RSA-related motion artifacts are. The uniplanar calibration cage applied in the study has a few fiducial and control markers, and some of the markers were occluded in radiographs. Whereas, the number of markers in the calibration cage is correlated with accuracy of 3D implant reconstruction.
Collapse
Affiliation(s)
- Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany; Department of Orthopaedic Surgery, Taizhou Second People's Hospital, 225599 Taizhou, China.
| |
Collapse
|
16
|
Hoornenborg D, Schweden AMC, Sierevelt IN, van der Vis HM, Kerkhoffs G, Haverkamp D. The influence of hydroxyapatite coating on continuous migration of a Zweymuller-type hip stem: a double-blinded randomised RSA trial with 5-year follow-up. Hip Int 2023; 33:73-80. [PMID: 33845623 DOI: 10.1177/11207000211006782] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND PURPOSE Adding hydroxyapatite to a stem to enhance ingrowth is a matter of debate, even less is known about the long-term effect on stability by adding hydroxyapatite (HA). Continuous migration in the first 2-5 years is an indicator of failed osteointegration or pending failure, enhancing the risk of loosening within 10 years after initial surgery. We performed a double-blinded randomised RSA trial with 5-year follow-up, to compare and analyse migration characteristics of the hydroxyapatite uncoated (HA-) and hydroxyapatite coated (HA+) Zweymuller-type hip stem. PATIENTS AND METHODS In this single-centre prospective randomised controlled trial 51 patients were randomised to receive either a HA- or a HA+ Zweymuller-type hip stem during total hip replacement. After 5 years, 35 patients were still eligible for follow-up evaluation. The migration pattern was measured by use of radio stereometric analysis (RSA) images up to 2 years to evaluate short-term migration, additionally RSA images were obtained 5 years postoperatively to assess late-term and continuous migration. Furthermore, the improvement of clinical outcome was analysed by HSS and HOOS ADL and pain subscales preoperative and after 5 years. RESULTS After initial settling of the implant, no significant migration occurred up to 5 years post-surgery for HA+ as well as HA- prostheses. Continuous migration within the 2-5 years' time interval was not observed for both HA+ nor the HA- group in all directions (p < 0.05). No significant difference between both groups was observed (p < 0.10). In both groups the HHS and HOOS improved significantly at 5 years compared to baseline for both groups. Improvement was not altered by the hydroxyapatite coating. No significant difference between both groups was observed (p > 0.58). CONCLUSIONS Addition of a hydroxyapatite coating did not influence the migration 5 years postoperatively for the Zweymuller-type hip stem.Clinical Trial Protocol number: NL 23524.048.08.
Collapse
Affiliation(s)
| | | | - Inger N Sierevelt
- Xpert Clinics, Orthopaedic Surgery, Amsterdam, The Netherlands.,Spaarne Gasthuis Academy, Haarlem, The Netherlands
| | | | | | | |
Collapse
|
17
|
Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design. Knee Surg Sports Traumatol Arthrosc 2022; 31:1433-1442. [PMID: 36201009 DOI: 10.1007/s00167-022-07171-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 09/12/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE Varus alignment of the tibial baseplate and limb > 3° might adversely affect baseplate fixation after total knee arthroplasty (TKA), especially for unrestricted kinematically aligned (KA) TKA which aligns a majority of baseplates in varus. The purposes of this study were to determine whether baseplate migration at 1 year (1) was significantly less than a stability limit of 0.5 mm, (2) increased over time, and (3) was related to varus alignment of the baseplate and limb after unrestricted KA TKA. METHODS Thirty-five patients underwent unrestricted KA TKA using a fixed-bearing, cemented, medial conforming tibial insert with posterior cruciate ligament retention. Using model-based radiostereometric analysis, maximum total point motion (MTPM) (i.e., largest displacement on the baseplate) was computed at 6 weeks, 3 months, 6 months, and 1 year postoperatively relative to the day of surgery. Baseplate and limb alignment were measured postoperatively on long-leg CT scanograms. RESULTS At 1 year, mean MTPM of 0.35 mm was significantly less than the 0.5 mm stability limit (p = 0.0002). Mean MTPM did not increase from 6 weeks to 1 year (p = 0.3047). Notably, 89% (31/35) of tibial baseplates and 46% (16/35) of limbs were > 3° varus. Baseplate and limb alignment had no relationship to MTPM at 1 year (|r|≤ 0.173, p ≥ 0.3276). CONCLUSION Low and non-progressive tibial baseplate migration 1 year after unrestricted KA TKA with a medial conforming design should allay any concern that unrestricted KA TKA increases risk of baseplate loosening due to varus alignment of the baseplate and limb. LEVEL OF EVIDENCE Level II, therapeutic prospective cohort study.
Collapse
|
18
|
Mobile-Bearing Total Ankle Replacement In Vivo Kinematic Assessment: A Prospective Study Protocol. J Clin Med 2022; 11:jcm11185328. [PMID: 36142975 PMCID: PMC9503301 DOI: 10.3390/jcm11185328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 09/07/2022] [Accepted: 09/08/2022] [Indexed: 11/17/2022] Open
Abstract
Total ankle prosthesis as a surgical solution in the case of end-stage osteoarthritis has seen a considerable increase in the last two decades. This study protocol arises from the need to understand the in vivo kinematics of mobile-bearing, flat tibial component total ankle replacement, evaluating the real range of motion and the reciprocal relationships between the components during normal motor tasks through the use of model-based radio-stereometric analysis (MB-RSA). In addition, pre- and post-operative evaluation of walking kinematics with inertial motion sensors, proprioception through a dedicated workstation, and clinical outcomes are discussed. We expect that based on our study protocol researchers will be able to improve future prosthetic designs and validate the setup of MB-RSA, as well as to understand "how an ankle prosthesis moves" once implanted in the patient.
Collapse
|
19
|
Niesen AE, Garverick AL, Howell SM, Hull ML. Error in Maximum Total Point Motion of a Tibial Baseplate is Lower with a Reverse-Engineered Model Versus a CAD Model Using Model-Based Radiosteremetric Analysis. J Biomech 2022; 143:111267. [DOI: 10.1016/j.jbiomech.2022.111267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 07/27/2022] [Accepted: 08/17/2022] [Indexed: 10/15/2022]
|
20
|
Jürgens-Lahnstein JH, Petersen ET, Laursen M, Hauskov Iversen C, Kaptein BL, Lindgren L, Stilling M. Development, construction, and validation of a thinner uniplanar calibration cage for radiostereometry. J Orthop Res 2022; 40:1645-1653. [PMID: 34664740 DOI: 10.1002/jor.25193] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 09/15/2021] [Accepted: 09/30/2021] [Indexed: 02/04/2023]
Abstract
Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient and equipment during RSA recordings. A thinner calibration cage would increase the recording area, facilitate handling of the cage, and ease integration of the cage with the RSA system. We developed a thinner calibration cage without compromise of accuracy and precision. First, we performed numerical simulations of an RSA system, and showed that the calibration cage thickness could be decreased to 140 mm maintaining accuracy and precision using 40 fiducial and 30 control markers. Second, we constructed a new calibration cage (NRT cage) according to the simulation results. Third, we validated the new calibration cage against two state-of-the-art calibration cages (Umeaa cage and Leiden cage) in a phantom study. All cages performed similar for marker-based analysis, except for y-rotation, where the Umeaa cage (SD = 0.064 mm) was less precise compared to the NRT (SD = 0.038 mm) and Leiden cages (0.042 mm) (p = .01). For model-based analysis the NRT cage had superior precision for translations (SD ≤ 0.054 mm) over the Leiden cage (SD ≤ 0.118 mm) and Umeaa cage (SD ≤ 0.093 mm) (p < .01). The combined study confirmed that the new and thinner calibration cage maintained accuracy and precision at the level of existing thicker calibration cages.
Collapse
Affiliation(s)
| | - Emil Toft Petersen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Mogens Laursen
- Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
| | | | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Lars Lindgren
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
21
|
Broberg JS, Naudie DDR, Lanting BA, Howard JL, Vasarhelyi EM, Teeter MG. Patient and Implant Performance of Satisfied and Dissatisfied Total Knee Arthroplasty Patients. J Arthroplasty 2022; 37:S98-S104. [PMID: 35569919 DOI: 10.1016/j.arth.2021.10.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 09/30/2021] [Accepted: 10/26/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Implant migration and altered kinematics have been thought to impact patient-reported outcome measures (PROMs) and postoperative patient satisfaction. In this study comparing satisfied and dissatisfied total knee arthroplasty (TKA) patients, we hypothesized that dissatisfied patients will have greater continuous implant migration and that there will be differences in joint kinematics, objective functional measurements, and PROMs between satisfied and dissatisfied patients. METHODS The Knee Society Score Satisfaction Subsection questions regarding satisfaction with function were used at least 6 months postoperation to split 50 patients into satisfied and dissatisfied groups. Patients underwent radiostereometric analysis to evaluate migration and kinematics. A wearable sensor system obtained objective measurements of patient function during timed up and go tests. PROMs were recorded preoperation and postoperation. RESULTS No statistically significant differences were found in migration between satisfied and dissatisfied groups. Statistical kinematic differences existed in lateral anteroposterior contact location at 20° and 40° of flexion at 1 year, where the dissatisfied group had more anteriorly located lateral contact. No statistically significant differences were present in objective functional measurements. Satisfied and dissatisfied groups had differing PROMs at 4 timepoints or greater for each questionnaire. CONCLUSIONS No differences were found in tibial component migration or objectively measured function between satisfied and dissatisfied patients. Functionally dissatisfied patients had more anteriorly positioned contact on the lateral condyle in early flexion and reported more pain and unmet expectations. These findings suggest that improving the functional satisfaction of TKA requires restoration of kinematics in early flexion and management of patient's pain and expectations.
Collapse
Affiliation(s)
- Jordan S Broberg
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada
| | - Douglas D R Naudie
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - James L Howard
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - Edward M Vasarhelyi
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - Matthew G Teeter
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada; Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
22
|
JØRGENSEN PB, KAPTEIN BL, SØBALLE K, JAKOBSEN SS, STILLING M. Polyethylene liner motion in dual-mobility hip prostheses: static and dynamic radiostereometry in 16 patients 1 year after operation. Acta Orthop 2022; 93:375-381. [PMID: 35347340 PMCID: PMC8958851 DOI: 10.2340/17453674.2022.2253] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). PATIENTS AND METHODS 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. RESULTS Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5-20), inclination 6° (2-12), and rotation 11° (5-48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12-46) and in liner/cup angle (larger articulation) was 6° (4-21). Static RSA showed changes in median liner anteversion from 7° (-12 to 23) postoperatively to 10° (-3 to 16) at 1-year follow-up and inclination from 42° (35-66) postoperatively to 59° (46-80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). INTERPRETATION The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.
Collapse
Affiliation(s)
- Peter Bo JØRGENSEN
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Bart L KAPTEIN
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Kjeld SØBALLE
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
| | - Stig S JAKOBSEN
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
| | - Maiken STILLING
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
23
|
Van de Kleut ML, Yuan X, Teeter MG, Athwal GS. Bony increased-offset reverse shoulder arthroplasty vs. metal augments in reverse shoulder arthroplasty: a prospective, randomized clinical trial with 2-year follow-up. J Shoulder Elbow Surg 2022; 31:591-600. [PMID: 34968693 DOI: 10.1016/j.jse.2021.11.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/10/2021] [Accepted: 11/16/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is rapidly being adopted as the standard procedure for a growing number of shoulder pathologies. Lateralization of the glenoid component is known to reduce the incidence of scapular notching and possibly improve postoperative range of motion. A number of methods are used for glenoid component lateralization, including bony increased-offset reverse shoulder arthroplasty (BIO-RSA) and porous metal-augmented baseplates. Presently, there exists little comparative literature on bone vs. metal lateralization. Therefore, the purpose of this study was to compare BIO-RSA to metal-augmented glenoid baseplates by assessing clinical outcomes and baseplate migration using model-based radiostereometric analysis. METHODS A power analysis indicated 40 patients would be required for this radiostereometric study. Therefore, 41 shoulders were prospectively randomized to receive either glenoid bone grafting (BIO-RSA) or a porous metal-augmented wedge-shaped titanium baseplate for primary reverse shoulder arthroplasty. At the time of primary surgery, all patients also underwent implantation of 8 tantalum marker beads in the glenoid and coracoid. Following surgery, participants were imaged using a calibrated, stereo radiographic technique. Radiographs were acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years postoperatively. Migration of the prosthesis was compared between bone and metal lateralization groups at each time point using a mixed effects model with Bonferroni test for multiple comparisons. Outcome measures were acquired preoperatively and 2 years postoperatively. RESULTS No significant differences were observed along any translation or rotation axis at any time point for either glenoid fixation group (P ≥ .175). Mean total glenoid component translation (± standard deviation) 2 years postoperatively was 0.4 ± 0.2 mm and 0.5 ± 0.3 mm for BIO-RSA and metal-augmented baseplates, respectively (P = .784). No significant differences were observed between groups in active range of motion; pain; American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score; Simple Shoulder Test score; Disabilities of the Arm, Shoulder, and Hand score; Constant Shoulder score; or Subjective Shoulder Value (P ≥ .117), with the exception of increased active external rotation in the BIO-RSA cohort (P = .036). CONCLUSION This randomized clinical trial assessed reverse shoulder arthroplasty glenoid component migration using model-based radiostereometric analysis. At 2-year follow-up, our results indicate both BIO-RSA and porous metal wedge augmented baseplates provide stable initial fixation, which is maintained at 2 years' follow-up, with no substantial differences in clinical outcomes.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada; School of Biomedical Engineering, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - George S Athwal
- Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Center, St Joseph's Health Care, London, ON, Canada.
| |
Collapse
|
24
|
Kok RY, Koster LA, Kaptein BL, Fiocco M, Keizer SB. A model-based radiostereometric analysis (RSA) randomized control trial evaluating the stability of the cementless Taperloc hip stem: the TapHip study. Acta Orthop 2022; 93:212-221. [PMID: 34984483 PMCID: PMC8815382 DOI: 10.2340/17453674.2021.1127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 12/02/2021] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - The Taperloc Complete hip is the successor of the Taperloc hip, aiming to increase range of motion and optimizing femoral fit with intermediate stem sizes. We evaluated whether these design changes affect fixation, and this RSA study compares 2-year migration. Patients and methods - In this prospective, multi-arm study, 100 patients were randomized to cementless total hip arthroplasty (THA) with Taperloc Complete full profile (TCFP), Taperloc Complete reduced distal (TCRD), Taperloc full profile (TFP), or Taperloc reduced distal (TRD). Migration was measured with model-based RSA postoperatively, and after 3, 12, and 24 months. Results - Results based on mixed-model analysis on 2-year postoperative RSA data from 74 patients showed similar subsidence (mm) in the first 3 months (mean [95% CI] TCFP 0.44 [0.20-0.69], TCRD 0.91 [0.40-1.42], TFP 0.71 [0.22-1.19], TRD 1.25 [0.58-1.91]) and stabilization afterwards. The TCFP showed statistically significantly less retroversion (°) at 2-year postoperatively compared with TFP and TCRD (mean [95% CI] TCFP: -0.13 [-0.64 to 0.38], TCRD: 0.84 [0.35-1.33], TFP: 0.56 [0.12-1.00], TRD: 0.37 [-0.35 to 1.09]). Interpretation - As expected in successful cementless THA, RSA shows stabilization after initial subsidence. Based on these results the Taperloc Complete stem is expected to have similar long-term fixation to the Taperloc stems. The reduced distal groups have larger, but statistically non-significant, initial migration compared with the TCFP group, which could be due to implantation in Dorr B, C femur types. It may be important to consider the femur shape for choosing a full profile or reduced distal stem to minimize migration.
Collapse
Affiliation(s)
- Ruben Y Kok
- Focuskliniek Orthopedie, Haaglanden Medical Center, the Hague; Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Lennard A Koster
- Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden.
| | - Marta Fiocco
- Department of Medical Statistics and Bioinformatics, Leiden University Medical Center, Leiden; Mathematical Institute, Leiden University, Leiden, The Netherlands.
| | - Stefan B Keizer
- Focuskliniek Orthopedie, Haaglanden Medical Center, the Hague.
| |
Collapse
|
25
|
Jørgensen PB, Kaptein BL, Søballe K, Jakobsen SS, Stilling M. Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study. Eur Radiol Exp 2021; 5:55. [PMID: 34907467 PMCID: PMC8671599 DOI: 10.1186/s41747-021-00253-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 11/08/2021] [Indexed: 12/02/2022] Open
Abstract
Background Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. Methods The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. Results The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. Conclusion Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. Trial registration ClinicalTrials.gov [NCT02301182], 25 October 2015. Supplementary Information The online version contains supplementary material available at 10.1186/s41747-021-00253-x.
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark.
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, 2333, Leiden, ZA, The Netherlands
| | - Kjeld Søballe
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| |
Collapse
|
26
|
Niesen AE, Garverick AL, Hull ML. Maximum Total Point Motion of Five Points Versus All Points in Assessing Tibial Baseplate Stability. J Biomech Eng 2021; 143:114502. [PMID: 34076233 DOI: 10.1115/1.4051347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Indexed: 11/08/2022]
Abstract
Maximum total point motion (MTPM), the point on a baseplate that migrates the most, has been used to assess the risk of tibial baseplate loosening using radiostereometric analysis (RSA). Two methods for determining MTPM for model-based RSA are to use either five points distributed around the perimeter of the baseplate or to use all points on the three-dimensional model. The objectives were to quantify the mean difference in MTPM using five points versus all points, compute the percent error relative to the 6-month stability limit for groups of patients, and determine the dependency of differences in MTPM on baseplate size and shape. A dataset of 10,000 migration values was generated using the mean and standard deviation of migration in six-degrees-of-freedom at 6 months from an RSA study. The dataset was used to simulate the migration of three-dimensional models (two baseplate shapes and two baseplate sizes) and calculate the difference in MTPM using five virtual points versus all points and the percent error (i.e., the difference in MTPM/stability limit) relative to the 6-month stability limit. The difference in the MTPM was about 0.02 mm, or 4% relative to the 6-month stability limit, which is not clinically important. Furthermore, results were not affected by baseplate shape or size. Researchers can decide whether to use five points or all points when computing MTPM for model-based RSA. The authors recommend using five points to maintain consistency with marker-based RSA.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis One Shields Avenue, Davis, CA 95616
| | - Anna L Garverick
- Department of Biomedical Engineering, University of California, Davis One Shields Avenue, Davis, CA 95616
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis One Shields Avenue, Davis, CA 95616; Department of Mechanical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA 95817
| |
Collapse
|
27
|
Niesen AE, Hull ML. Propagation of registration error into maximum total point motion to analyze tibial baseplate stability at six months using marker-based and model-based RSA. J Biomech 2021; 127:110651. [PMID: 34371473 DOI: 10.1016/j.jbiomech.2021.110651] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 07/05/2021] [Accepted: 07/25/2021] [Indexed: 11/28/2022]
Abstract
Maximum total point motion (MTPM) of a tibial baseplate at 6 months is used to predict long-term aseptic loosening after total knee arthroplasty. However, the propagation of registration error into MTPM for stable baseplates (i.e. baseplates with MTPM < 0.5 mm) manifested as bias (i.e. systematic error) and precision (i.e. random error) has not been quantified and compared to the 6-month stability limit for marker-based and model-based RSA, which have different magnitudes of registration error. To determine the bias and precision in MTPM for stable baseplates, registration errors in six degrees of freedom reported in the literature for marker-based and model-based RSA were applied to an example baseplate using computer simulations. Results revealed that the bias in MTPM for stable baseplates with model-based RSA is three to four times that of marker-based RSA, and that the precision in MTPM for stable baseplates with model-based RSA is double that of marker-based RSA. This assessment of bias and precision in MTPM for stable baseplates led to a method for adjusting the 6-month stability limit for model-based RSA where half the width of the 95% confidence interval on the mean MTPM and the bias in MTPM for marker-based RSA were subtracted from 0.5 mm to compute true MTPM. The bias in MTPM and half the width of the 95% confidence interval on the mean MTPM for model-based RSA were then added to the true MTPM to obtain the adjusted stability limit for model-based RSA which ranged from 0.57 mm to 0.64 mm.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Mechanical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento CA, 95817, USA.
| |
Collapse
|
28
|
de Waard S, Sierevelt IN, Jonker R, Hoornenborg D, van der Vis HM, Kerkhoffs GMMJ, Haverkamp D. The migration pattern and initial stability of the Optimys short stem in total hip arthroplasty: a prospective 2-year follow-up study of 33 patients with RSA. Hip Int 2021; 31:507-515. [PMID: 31971010 DOI: 10.1177/1120700020901844] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND PURPOSE The consensus that bone stock preservation and optimal restoration of offset and leg length is important in total hip arthroplasty is now widespread, especially for young and active patients. Short stems seem promising in this aspect, though implant stability is still of concern. This study looked at the migration pattern of the Optimys short stem through RSA analysis. PATIENTS AND METHODS 40 patients were included. RSA images were made directly postoperatively (within 5 days), at 6 weeks and at 3, 6, 12 and 24 months. Double examinations were made for precision measurement. HOOS and pain scores were obtained preoperatively and at 2 years. 4 patients were excluded due to protocol violation and 1 patient was excluded for RSA analysis with a CN number >110. 2 patients were lost to follow-up after 3 and 6 months (n = 1 lost, n = 1 deep infection, respectively). RESULTS Mean age was 60 years with a mean BMI of 27. RSA analysis of 34 patients showed a significant initial median proximodistal translation (subsidence) of 0.21 mm (IQR 0.64-0.06) and anteversion-retroversion rotation of 0.59° (IQR 0.01-1.34) at 6 weeks, after which the stem stabilises and showed no further significant movement. Median migration in other directions was small. 4 patients had an initial subsidence of >2 mm, all showed secondary stabilisation. HOOS outcomes were satisfactory, with the domain symptoms and pain showing a median score of 95/100 at 2 years. CONCLUSIONS After initial migration the Optimys achieves secondary stabilisation, suggesting low risk on long-term aseptic loosening. CLINICAL TRIALS REGISTRATION NL47055.048.13.
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Renee Jonker
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Daniel Hoornenborg
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Harm M van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
29
|
Koster LA, Meinardi JE, Kaptein BL, Van der Linden-Van der Zwaag E, Nelissen RGHH. Two-year RSA migration results of symmetrical and asymmetrical tibial components in total knee arthroplasty: a randomized controlled trial. Bone Joint J 2021; 103-B:855-863. [PMID: 33934647 DOI: 10.1302/0301-620x.103b5.bjj-2020-1575.r2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). METHODS A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. RESULTS A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. CONCLUSION The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855-863.
Collapse
Affiliation(s)
- Lennard A Koster
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Joris E Meinardi
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Bart L Kaptein
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Rob G H H Nelissen
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
30
|
Christensen R, Petersen ET, Jürgens-Lahnstein J, Rytter S, Lindgren L, De Raedt S, Brüel A, Stilling M. Assessment of knee kinematics with dynamic radiostereometry: Validation of an automated model-based method of analysis using bone models. J Orthop Res 2021; 39:597-608. [PMID: 33030797 DOI: 10.1002/jor.24875] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 07/26/2020] [Accepted: 10/06/2020] [Indexed: 02/04/2023]
Abstract
Radiostereometic analysis (RSA) is a precise method for the functional assessment of joint kinematics. Traditionally, the method is based on tracking of surgically implanted bone markers and analysis is user intensive. We propose an automated method of analysis based on models generated from computed tomography (CT) scans and digitally reconstructed radiographs. The study investigates method agreement between marker-based RSA and the CT bone model-based RSA method for assessment of knee joint kinematics in an experimental setup. Eight cadaveric specimens were prepared with bone markers and bone volume models were generated from CT-scans. Using a mobile fixture setup, dynamic RSA recordings were obtained during a knee flexion exercise in two unique radiographic setups, uniplanar and biplanar. The method agreement between marker-based and CT bone model-based RSA methods was compared using bias and LoA. Results obtained from uniplanar and biplanar recordings were compared and the influence of radiographic setup was considered for clinical relevance. The automated method had a bias of -0.19 mm and 0.11° and LoA within ±0.42 mm and ±0.33° for knee joint translations and rotations, respectively. The model pose estimation of the tibial bone was more precise than the femoral bone. The radiographic setup had no clinically relevant effect on results. In conclusion, the automated CT bone model-based RSA method had a clinical precision comparable to that of marker-based RSA. The automated method is non-invasive, fast, and clinically applicable for functional assessment of knee kinematics and pathomechanics in patients.
Collapse
Affiliation(s)
- Rasmus Christensen
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Emil Toft Petersen
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark.,University Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark
| | - Jonathan Jürgens-Lahnstein
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Søren Rytter
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
| | - Lars Lindgren
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Radiology, Aarhus University Hospital, Aarhus N, Denmark
| | - Sepp De Raedt
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,NRT X-RAY, Hasselager, Denmark
| | - Annemarie Brüel
- Department of Biomedicine, Aarhus University, Aarhus C, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaeadic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark.,Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
31
|
Torle J, Thillemann JK, Petersen ET, Madsen F, Søballe K, Stilling M. Less polyethylene wear in monobloc compared to modular ultra-high-molecular-weight-polyethylene inlays in hybrid total knee arthroplasty: A 5-year randomized radiostereometry study. Knee 2021; 29:486-499. [PMID: 33743263 DOI: 10.1016/j.knee.2021.02.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 11/19/2020] [Accepted: 02/22/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND A modular polyethylene (PE) inlay in total knee arthroplasty (TKA) may wear on both sides. PE particles may induce osteolysis, which can lead to implant loosening. The aim of this study was to determine if PE wear in monobloc TKA differs from that ofmodular TKA at 60-month follow-up. PATIENTS AND METHODS In a prospective, patient-blinded trial, 50 patients were randomized to hybrid TKA surgery with either acementless high-porosity trabecular-metal tibial component with a monobloc UHMWPE inlay (MONO-TM) or a cementless low-porosity screw-augmented titanium fiber-mesh tibial component with a modular UHMWPE inlay (MODULAR-FM). Radiostereometry was used to measure PE wear and tibial component migration. RESULTS At 60-monthfollow-up, mean PE wear of the medial compartment was 0.24 mm and 0.61 mm and mean PE wear of the lateral compartment was 0.31 mm and 0.82 mm for the MONO-TM and the MODULAR-FM groups, respectively (p < 0.01). The PE wear-rate was 0.05 mm (95% CI 0.03-0.08) in the MONO-TM group and 0.14 mm (95% CI 0.12-0.17) in the MODULAR-FM group (p < 0.01). Total translation at 60 months was mean 0.30 mm (95% CI 0.10-0.51) less (p < 0.01) for MONO-TM compared with MODULAR-FM tibial components. The majority of tibial components were stable (<0.2 mm MTPM) from 12 to 24-month and 24 to 60-month follow-up. CONCLUSION At mid-term follow-up, monobloc PE inlay wear was approximately 40% of that of the modular PE inlay wear, which suggest that back-side wear of modular PE inlays is a significant contributor of PE wear in hybrid TKA.
Collapse
Affiliation(s)
- Johan Torle
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.
| | - Janni Kjærgaard Thillemann
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopeadics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
| | - Emil Toft Petersen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopeadics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark
| | - Frank Madsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark; Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
32
|
van Ooij B, Sierevelt IN, van der Vis HM, Hoornenborg D, Haverkamp D. What is the role of cemented fixation in total knee arthroplasty? The two-year results of a randomized RSA controlled trial. Bone Joint J 2021; 103-B:98-104. [PMID: 33380179 DOI: 10.1302/0301-620x.103b1.bjj-2020-0788.r1] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
AIMS For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. METHODS A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. RESULTS RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. CONCLUSION Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98-104.
Collapse
Affiliation(s)
- Bas van Ooij
- SCORE Foundation, Specialized Center of Orthopedic Research and Education/Xpert Clinics Orthopedie, Amsterdam, The Netherlands.,Cohesie, Occupational Health Service, Voorthuizen, The Netherlands
| | - Inger N Sierevelt
- SCORE Foundation, Specialized Center of Orthopedic Research and Education/Xpert Clinics Orthopedie, Amsterdam, The Netherlands.,Orthopaedic Department, Spaarne Gasthuis Academy, Hoofddorp, The Netherlands
| | - Harm M van der Vis
- SCORE Foundation, Specialized Center of Orthopedic Research and Education/Xpert Clinics Orthopedie, Amsterdam, The Netherlands
| | - Daniël Hoornenborg
- SCORE Foundation, Specialized Center of Orthopedic Research and Education/Xpert Clinics Orthopedie, Amsterdam, The Netherlands
| | - Daniël Haverkamp
- SCORE Foundation, Specialized Center of Orthopedic Research and Education/Xpert Clinics Orthopedie, Amsterdam, The Netherlands
| |
Collapse
|
33
|
Niesen AE, Hull ML. Propagation of registration errors into the change in maximum total point motion for determining stability of tibial baseplates. Comput Methods Biomech Biomed Engin 2021; 24:1019-1025. [PMID: 33400600 DOI: 10.1080/10255842.2020.1865324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The change in maximum total point motion (ΔMTPM) is used to predict long-term risk of tibial baseplate loosening, however, effects of registration error on ΔMTPM have not been quantified for marker-based and model-based radiostereometric analysis (RSA). Registration errors for marker-based and model-based RSA were applied to a stable tibial baseplate in MATLAB simulations to determine the bias and precision in ΔMTPM and the proportions of baseplates which fell above the continuous migration stability limit. No bias error occurred, however, the precision of ΔMTPM was twice as large for model-based RSA than marker-based RSA, resulting in about 25% of stable baseplates falling above the continuous migration stability limit for model-based RSA. Reseachers should be aware of these limitations when applying this stability limit to assess tibial baseplate stability using model-based RSA.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California Davis, Davis, CA, USA
| | - Maury L Hull
- Department of Biomedical Engineering, University of California Davis, Davis, CA, USA.,Department of Mechanical Engineering, University of California Davis, Davis, CA, USA.,Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, USA
| |
Collapse
|
34
|
Affiliation(s)
- Stephan M Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway,
| |
Collapse
|
35
|
Reorienting the tibial baseplate improves the registration accuracy of model-based radiostereometric analysis. J Biomech 2020; 113:110078. [DOI: 10.1016/j.jbiomech.2020.110078] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 10/04/2020] [Accepted: 10/16/2020] [Indexed: 11/19/2022]
|
36
|
[Early assessment of the risk of later implantloosening using Roentgen Sterophotogrammetric Analysis (RSA)]. DER ORTHOPADE 2020; 49:1042-1048. [PMID: 33108489 DOI: 10.1007/s00132-020-04027-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Aseptic implant loosening is the most common cause of implant revisions in total hip and total knee arthroplasty. Roentgen Stereophotogrammetric Analysis (RSA) represents the current gold standard for the in-vivo assessment of implant fixation. PRESENT SITUATION Long-term clinical trials have shown that continuous implant migration within the first two postoperative years correlates strongly with a later aseptic loosening. Thus, the implant migration measured with RSA can be regarded as a reliable surrogate marker for later implant loosening. Over the past 40 years, RSA has been continuously further developed, and the model-based RSA approach has reduced the effort involved since markers attached to implant are no longer needed. PERSPECTIVES The RSA method is gaining importance in the certification process of new orthopaedic implants-for example, the Dutch Orthopedic Society has recommended phased-introduction and RSA studies for new hip implants. Furthermore, in the context of the new EU Medical Device Regulation (MDR), which took effect in May 2017, RSA gained relevance for investigating clinically unproven implants. Critics who associate MDR with hindering innovation can be countered in that the RSA method provides a predictive assessment of implant fixation after only two years of follow-up, which is significantly shorter than standard long-term clinical trials.
Collapse
|
37
|
Kaptein BL, den Hollander P, Thomassen B, Fiocco M, Nelissen RGHH. A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design. Bone Joint J 2020; 102-B:1158-1166. [PMID: 32862688 PMCID: PMC7468556 DOI: 10.1302/0301-620x.102b9.bjj-2020-0096.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
AIMS The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). METHODS A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively. RESULTS The overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43° (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08° (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components. The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001). CONCLUSION In the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer. Level of Evidence: 1 (randomized controlled clinical trial) Cite this article: Bone Joint J 2020;102-B(9):1158-1166.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Peter den Hollander
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, Netherlands
| | - Bregje Thomassen
- Faculty Health, Nutrition and Sports, The Hague University of Applied Sciences, The Hague, Netherlands
| | - Martha Fiocco
- Mathematical Institute, Leiden University, Leiden, The Netherlands.,Medical Statistics, Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
38
|
Abstract
Background and purpose - Radiostereometric analysis (RSA) is the gold standard to study micromotion of joint replacements. RSA requires the acquisition of additional radiographs increasing the radiation dose of patients included in RSA studies. It is important to keep this dose as low as possible. Effective radiation dose (ED) measurements of RSA radiographs for different joints were done by Teeuwisse et al. some years ago using conventional radiology (CR); for total hip arthroplasty (THA), Teeuwisse et al. reported an ED of 0.150 milliSievert (mSv). With the modern digital radiography (DR) roentgen technique the ED is expected to be less.Material and methods - In this phantom study, simulating a standard patient, the ED for hip RSA radiographs is determined using DR under a variety of different roentgen techniques. The quality of the RSA radiographs was assessed for feasibility in migration analysis using a (semi-)automatic RSA analysis technique in RSA software.Results - A roentgen technique of 90 kV and 12.5 mAs with additional 0.2 copper (Cu) + 1 mm aluminum (Al) external tube filters results in an ED of 0.043 mSv and radiographs suitable for analysis in RSA software.Interpretation - The accumulated ED for a standard patient in a 2-year clinical hip RSA study with 5 follow-up moments and a double acquisition is below the acceptable threshold of 1.0 mSv provided by the EU radiation guideline for studies increasing knowledge for general health.
Collapse
Affiliation(s)
- Ian F Blom
- Department of Radiology, Reinier de Graaf Groep, Delft, The Netherlands
| | - Lennard A Koster
- Department of Orthopaedic Surgery, Leids Universitair Medisch Centrum, Leiden, The Netherlands
| | - Bart Ten Brinke
- Department of Orthopaedic Surgery, Reinier de Graaf Groep, Delft, The Netherlands
| | - Nina M C Mathijssen
- Department of Orthopaedic Surgery, Reinier de Graaf Groep, Delft, The Netherlands
| |
Collapse
|
39
|
Abstract
AIMS Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome. METHODS In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results. RESULTS In addition to the initial migration pattern of distal migration (subsidence, Y-translation) and retroversion (Y-rotation) also exhibited by the Taperloc stem, the GTS stem showed an initial migration pattern of varization (X-translation combined with Z-rotation) and posterior translation (Z-translation). However, all components stabilized aside from one Taperloc stem which became loose secondary to malposition and was later revised. Clinical outcomes and complications were not statistically significantly different with the numbers available. CONCLUSION A substantially different and more extensive initial migration pattern was seen for the GTS stem compared to the Taperloc stem. Although implant stabilization was achieved, excellent long-term survival similar to that of the Taperloc stem should not be inferred. Especially in the absence of clinically proven relevant improvement, widespread usage should be postponed until long-term safety has been established. Cite this article: Bone Joint J 2020;102-B(6):699-708.
Collapse
Affiliation(s)
- Marc J Nieuwenhuijse
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, the Netherlands
| | - Stephan B W Vehmeijer
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, the Netherlands
| | - Nina M C Mathijsen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, the Netherlands
| | - Stefan B Keizer
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, the Netherlands
| |
Collapse
|
40
|
RSA-tested TKA Implants on Average Have Lower Mean 10-year Revision Rates Than Non-RSA-tested Designs. Clin Orthop Relat Res 2020; 478:1232-1241. [PMID: 32187101 PMCID: PMC7319401 DOI: 10.1097/corr.0000000000001209] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The number of revisions after TKA is expected to rise because of aging populations in many countries and because patients are undergoing TKA at younger ages. Aseptic loosening is a major reason for late revision, which can be predicted by radiostereometric analysis (RSA) of small groups of patients at 2 years of follow-up. RSA is therefore an ideal tool to assess new TKA designs before they are introduced to the market, although not every TKA design has been studied with RSA. If RSA-tested TKA designs have lower 10-year revision rates in national registries than non-RSA-tested TKA designs, RSA testing of all new designs could be advocated. QUESTIONS/PURPOSES In this study, we asked: Is there a difference in the all-cause revision rate between non-RSA-tested and RSA-tested TKA designs registered in national knee arthroplasty registries at 5 and 10 years of follow-up? METHODS Knee arthroplasty registries were identified through the European Federation of National Associations of Orthopaedics and Traumatology webpage and through a manual internet search. Inclusion criteria were a minimum follow-up duration of 10 years and available revision or survival data per TKA design. Twenty-six registries were identified; seven were included comprising 339 TKA designs, of which 236 designs were classified as RSA-tested and 103 as non-RSA-tested. Six registries were excluded because no report was published. One registry was excluded because no fixation method was mentioned (79 TKA designs). Another registry was excluded because there was no 10-year data available (22 non-RSA-tested designs; 10 RSA-tested designs). Eleven registries were excluded because they did not provide revision rates per design and had not reached 10 years follow-up. The revision rates with their standard errors were extracted per design. We used the data from a recent meta-analysis to identify whether a TKA design was previously tested with RSA. This meta-analysis found 53 RSA studies comprising 70 different TKA designs. The prosthesis model, fixation method and insert type were extracted from these RSA-studies. The design characteristics of the TKA reported in the knee arthroplasty registries were also extracted, and if possible, matched to the TKA designs reported in the RSA-studies. At 5 years of follow-up, 191 TKA designs were identified as non-RSA-tested and 92 were identified as RSA-tested. At 10 years of follow-up, 154 TKA designs and 74 TKA designs were classified as non-RSA-tested and RSA-tested, respectively. A random-effects model using the Metafor Package in R statistics was used to estimate the pooled revision rate at 5 and 10 years of follow-up for both groups. The difference in revision rates between groups at 5 and 10 years of follow-up was estimated by including RSA as a factor in the random-effects model. RESULTS Mean all-cause revision rates at 5 years for non-RSA-tested and RSA-tested implants were 3.6% (95% CI 3.4 to 3.8) and 2.9% (95% CI 2.7 to 3.0), with a mean difference of 0.6% favoring RSA-tested implants (95% CI 0.4 to 0.8; p < 0.001). Mean all-cause revision rates at 10 years for non-RSA-tested and RSA-tested implants were 5.5% (95% CI 5.2 to 5.9) and 4.4% (95% CI 4.1 to 4.7), with a mean difference of 0.9% favoring RSA-tested implants (95% CI 0.4 to 1.3; p < 0.001). CONCLUSIONS Although there are exceptions, across registries, TKA designs that have been tested in an RSA setting have a slightly lower (about 1%) mean all-cause revision rate at 5-year and 10-year follow-up than those tested in a non-RSA setting. Acknowledging the inherent limitations of this observational study, a risk difference of 1% could potentially translate into an approximate 20% decrease in revision burden up to 10 years, which may have a profound impact on patient morbidity and health-related costs. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
41
|
Allab A, Vazquez C, Cresson T, Guise JD. Calibration of Stereo Radiography System for Radiostereometric Analysis Application. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4859-4862. [PMID: 31946949 DOI: 10.1109/embc.2019.8857531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This paper describes a new alternative to conventional radiography system currently used for radiostereometric analysis studies. Instead of using two non-calibrated X-ray sources with a cumbersome calibration cage, we propose to use the biplanar radiography EOS system. Its fixed configuration provides a preliminary calibration and a much simpler acquisition protocol. A flexible and accurate calibration method is presented to optimize EOS default calibration using a simple object and a self-calibration method. To validate our system, we calculate the 3D reconstruction error of a known object. Results showed an accuracy of 70±11μm and 0.05±0.02° for translation and rotation respectively, and an average epipolar error of 23±03μm.
Collapse
|
42
|
Xu J, Sonntag R, Kretzer JP, Taylor D, Forst R, Seehaus F. Model-Based Roentgen Stereophotogrammetric Analysis to Monitor the Head-Taper Junction in Total Hip Arthroplasty in Vivo-And They Do Move. MATERIALS 2020; 13:ma13071543. [PMID: 32230788 PMCID: PMC7178274 DOI: 10.3390/ma13071543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/23/2020] [Accepted: 03/24/2020] [Indexed: 12/01/2022]
Abstract
Model-based Roentgen stereophotogrammetric analysis (RSA) using elementary geometrical shape (EGS) models allows migration measurement of implants without the necessity of additional attached implant markers. The aims of this study were: (i) to assess the possibility of measuring potential head–taper movement in THA in vivo using model-based RSA and (ii) to prove the validity of measured head–taper migration data in vitro and in vivo. From a previous RSA study with a 10 years follow-up, retrospectively for n = 45 patients head–taper migration was calculated as the relative migration between femoral ball head and taper of the femoral stem using model-based RSA. A head–taper migration of 0.026 mm/year can be detected with available RSA technology. In vitro validation showed a total migration of 268 ± 11 µm along the taper axis in a similar range to what has been reported using the RSA method. In vivo, a proof for interchangeable applicability of model-based RSA (EGS) and standard marker-based RSA methods was indicated by a significant deviation within the migration result after 12-month follow-up for all translation measurements, which was significantly correlated to the measured head–taper migration (r from 0.40 to 0.67; p < 0.05). The results identified that model-based RSA (EGS) could be used to detect head–taper migration in vivo and the measured movement could be validated in vitro and in vivo as well. Those findings supported the possibility of applying RSA for helping evaluate the head–taper corrosion related failure (trunnionosis).
Collapse
Affiliation(s)
- Jing Xu
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - J. Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Dominic Taylor
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Frank Seehaus
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Erlangen-Nürnberg, 91054 Erlangen, Germany
- Correspondence:
| |
Collapse
|
43
|
Lindgren L, Jørgensen PB, Mørup RMS, Jensen M, Rømer L, Kaptein B, Stilling M. Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip. Radiography (Lond) 2020; 26:e45-e51. [PMID: 32052775 DOI: 10.1016/j.radi.2019.10.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 08/30/2019] [Accepted: 10/22/2019] [Indexed: 01/28/2023]
Abstract
INTRODUCTION Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. METHODS A femoral stem with 3 bead-towers was fixed in a saw bone with bone-markers (phantom), and series of RSA examinations within optimal (5 × 5 cm and 5°) and extreme (20 × 30 cm and 30°) phantom positions were obtained. Double-examination RSA of 12 patients with the same femoral stem type were analyzed. Both model-based (CAD) and marker-based (MM) analysis was used. Precision was reported as standard deviation of differences. RESULTS Precision for translations in the optimal and extreme phantom position were below 0.06 mm and 0.02 mm for MM analysis, and below 0.05 mm and 0.18 mm for CAD analysis, respectively. Precision for rotations in the optimal and extreme phantom rotation were below 0.18° and 0.26° for MM analysis, and below 0.34° and 0.52° for CAD analysis, respectively. Clinical precision was 0.29 mm and 0.44° for MM analysis, and 0.40 mm and 1.59° for CAD analysis. CONCLUSION Extreme differences in patient position during RSA examination negatively affects precision, and CAD model-analysis was more sensitive than MM analysis. Longitudinal translation and rotation about the long stem-axis are the effect parameters which are most affected by position and rotation changes, and also the best indicators of implant loosening. IMPLICATIONS FOR PRACTICE Based on our research, we recommend that similar patient positioning between follow-up RSA examinations is debated and prioritized.
Collapse
Affiliation(s)
- L Lindgren
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - P B Jørgensen
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - R M S Mørup
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - M Jensen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - L Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - B Kaptein
- Biomechanics and Imaging Group (BIG), Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, the Netherlands.
| | - M Stilling
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| |
Collapse
|
44
|
Mohammad HR, Campi S, Kennedy JA, Judge A, Murray DW, Mellon SJ. Long-term in vivo wear of different bearing types used for the Oxford Unicompartmental Knee Replacement. Bone Joint Res 2019; 8:535-543. [PMID: 31832173 PMCID: PMC6888733 DOI: 10.1302/2046-3758.811.bjr-2019-0163.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objectives The aim of this study was to determine the polyethylene wear rate of Phase 3 Oxford Unicompartmental Knee Replacement bearings and to investigate the effects of resin type and manufacturing process. Methods A total of 63 patients with at least ten years’ follow-up with three bearing types (1900 resin machined, 1050 resin machined, and 1050 resin moulded) were recruited. Patients underwent full weight-bearing model-based radiostereometric analysis to determine the bearing thickness. The linear wear rate was estimated from the change in thickness divided by the duration of implantation. Results The wear rate for 1900 resin machined (n = 19), 1050 machined (n = 21), and 1050 moulded bearings (n = 23) were 60 µm/year (sd 42), 76 µm/year (sd 32), and 57 µm/year (sd 30), respectively. There was no significant difference between 1900 machined and 1050 machined (p = 0.20), but 1050 moulded had significantly less wear than the 1050 machined (p = 0.05). Increasing femoral (p < 0.001) and tibial (p < 0.001) component size were associated with increasing wear. Conclusion Wear rate is similar with 1050 and 1900 resin, but lower with moulded bearings than machined bearings. The currently used Phase 3 bearings wear rate is low (1050 moulded, 57 µm/year), but higher than the previously reported Phase 2 bearings (1900 moulded, 20 µm/year). This is unlikely to be due to the change in polyethylene but may relate to the minimally invasive approach used with the Phase 3. This approach, as well as improving function and thus increasing activity levels, may increase the risk of surgical errors, such as impingement or bearing overhang, which can increase wear. Surgeons should aim to use 4 mm thick bearings rather than 3 mm thick bearings in young patients, unless they are small and need conservative bone resections. Cite this article: Bone Joint Res 2019;8:535–543.
Collapse
Affiliation(s)
- Hasan R Mohammad
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK; Oxford University Hospitals. Nuffield Orthopaedic Centre, Oxford, UK
| | - Stefano Campi
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK; Oxford University Hospitals. Nuffield Orthopaedic Centre, Oxford, UK
| | - James A Kennedy
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK; Oxford University Hospitals. Nuffield Orthopaedic Centre, Oxford, UK
| | - Andrew Judge
- Musculoskeletal Research Unit, University of Bristol, Bristol, UK; Director MSc Orthopaedic Surgery, University of Bristol; Honorary Professor, Centre for Statistics in Medicine, University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK; Oxford University Hospitals. Nuffield Orthopaedic Centre, Oxford, UK
| | - Stephen J Mellon
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
45
|
Gascoyne T, Parashin S, Teeter M, Bohm E, Laende E, Dunbar M, Turgeon T. In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis. Bone Joint J 2019; 101-B:1348-1355. [DOI: 10.1302/0301-620x.101b11.bjj-2018-1447.r2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm3/year (supine) and 39.3 mm3/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm3. No significant associations were found between patient demographics or function scores and measured wear. Conclusion In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA. Cite this article: Bone Joint J 2019;101-B:1348–1355.
Collapse
Affiliation(s)
- Trevor Gascoyne
- Orthopaedic Innovation Centre, Winnipeg, Canada
- Concordia Joint Replacement Group, Winnipeg, Canada
| | | | - Matthew Teeter
- London Health Sciences Centre, Western University, London, Canada
| | - Eric Bohm
- Orthopaedic Innovation Centre, Winnipeg, Canada
- Concordia Joint Replacement Group, Winnipeg, Canada
- University of Manitoba, Winnipeg, Canada
| | - Elise Laende
- QEII Health Sciences Centre, Dalhousie University and Nova Scotia Health Authority, Halifax, Canada
| | - Michael Dunbar
- QEII Health Sciences Centre, Dalhousie University and Nova Scotia Health Authority, Halifax, Canada
| | - Thomas Turgeon
- Concordia Joint Replacement Group, Winnipeg, Canada
- University of Manitoba, Winnipeg, Canada
| |
Collapse
|
46
|
van Hamersveld KT, Marang-van de Mheen PJ, Nelissen RGHH. The Effect of Coronal Alignment on Tibial Component Migration Following Total Knee Arthroplasty: A Cohort Study with Long-Term Radiostereometric Analysis Results. J Bone Joint Surg Am 2019; 101:1203-1212. [PMID: 31274722 DOI: 10.2106/jbjs.18.00691] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Recent short-term studies of total knee arthroplasty (TKA) have claimed improved clinical outcomes and implant survival when aiming to restore constitutional joint kinematics, as compared with neutral mechanical axis alignment. However, implant durability may be compromised when aligned in varus or valgus. With use of data pooled from 3 long-term radiostereometric analysis (RSA) studies, the aim of the present study was to assess the effects of coronal alignment on tibial component migration. METHODS Coronal alignment parameters from full-leg radiographs were measured and the constitutional leg alignment was determined for each patient. We evaluated the effect of the postoperative hip-knee-ankle angle, relative to both the mechanical axis and the constitutional alignment, on tibial component migration. In-range knees were defined as within ±3° of either the neutral mechanical axis or constitutional alignment of the patient. Analysis was performed with a linear mixed-effects model, corrected for study, age, sex, preoperative alignment, diagnosis, and body mass index. RESULTS A total of 85 cemented TKAs were included, of which 3 were revised for aseptic loosening and another 4 were considered loose. The median follow-up was 11 years. No loose tibial components were observed in mechanically in-range knees, whereas all loose tibial components were out of range. Mechanically varus knees showed the highest mean migration (maximum total point motion) of 1.55 mm (95% confidence interval [CI], 1.16 to 2.01 mm) after 5 years, compared with 1.07 mm (95% CI, 0.63 to 1.64 mm) and 0.77 mm (95% CI, 0.53 to 1.06 mm) for valgus and in-range knees, respectively (p < 0.001). In contrast, looking at constitutional alignment, loose tibial components were found among both constitutionally in-range and out-of-range knees. Mixed-model analysis showed comparable migration among constitutionally in-range, more-in-varus, and more-in-valgus aligned knees. CONCLUSIONS Mechanically out-of-range alignment, especially mechanical varus, led to higher tibial component migration. However, matching the constitutional alignment of the patient did not preclude high implant migration. RSA trials randomizing different alignment techniques are needed to confirm the results of the present study. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Koen T van Hamersveld
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M.), Leiden University Medical Center, Leiden, the Netherlands
| | - Perla J Marang-van de Mheen
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M.), Leiden University Medical Center, Leiden, the Netherlands
| | - Rob G H H Nelissen
- Departments of Orthopaedics (K.T.v.H. and R.G.H.H.N.) and Biomedical Data Sciences (P.J.M.-v.d.M.), Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
47
|
Weight Bearing Activities change the Pivot Position after Total Knee Arthroplasty. Sci Rep 2019; 9:9148. [PMID: 31235890 PMCID: PMC6591446 DOI: 10.1038/s41598-019-45694-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 06/10/2019] [Indexed: 01/16/2023] Open
Abstract
The knee joint center of rotation is altered in the absence of the anterior cruciate ligament, which leads to substantially higher variance in kinematic patterns. To overcome this, total knee arthroplasty (TKA) designs with a high congruency in the lateral compartment have been proposed. The purpose of this study was to analyze the influence of a lateral pivot TKA-design on in-vivo knee joint kinematics. Tibiofemoral motion was retrospectively addressed in 10 patients during unloaded flexion-extension and loaded lunge using single plane fluoroscopy. During the unloaded flexion-extension movement, the lateral condyle remained almost stationary with little rollback at maximum flexion. The medial condyle exhibited anterior translation during the whole flexion cycle. During the loaded lunge movement, a higher degree of rollback compared to the unloaded activity was observed on the lateral condyle, whereas the medial condyle remained almost stationary. The results showed a clear lateral pivot during the unloaded activity, reflective of the implant’s geometric characteristics, and a change to a medial pivot and a higher lateral rollback during the weight-bearing conditions, revealing the impact of load and muscle force. It remains unclear if the kinematics with a lateral TKA design could be considered as physiological, due to the limited knowledge available on native knee joint kinematics.
Collapse
|
48
|
van Hamersveld KT, Marang–van de Mheen PJ, Koster LA, Nelissen RGHH, Toksvig-Larsen S, Kaptein BL. Marker-based versus model-based radiostereometric analysis of total knee arthroplasty migration: a reanalysis with comparable mean outcomes despite distinct types of measurement error. Acta Orthop 2019; 90:366-372. [PMID: 31017513 PMCID: PMC7025693 DOI: 10.1080/17453674.2019.1605692] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods - All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland-Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results - Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation - At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error.
Collapse
Affiliation(s)
- Koen T van Hamersveld
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands; ,Correspondence:
| | | | - Lennard A Koster
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands;
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands;
| | - Sören Toksvig-Larsen
- Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden and Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands;
| |
Collapse
|
49
|
Akhbari B, Morton A, Moore D, Weiss APC, Wolfe SW, Crisco J. Kinematic Accuracy in Tracking Total Wrist Arthroplasty with Biplane Videoradiography using a CT-generated Model. J Biomech Eng 2019; 141:2724662. [PMID: 30729978 DOI: 10.1115/1.4042769] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Indexed: 12/21/2022]
Abstract
Total Wrist Arthroplasty (TWA) for improving the functionality of severe wrist joint pathology has not had the same success, in parameters such as motion restoration and implant survival, as hip, knee, and shoulder arthroplasty. These other arthroplasties have been studied extensively, including the use of biplane videoradiography (BVR) that has allowed investigators to study the in-vivo motion of the total joint replacement during dynamic activities. The wrist has not been a previous focus, and utilization of BVR for wrist arthroplasty presents unique challenges due to the design characteristics of TWAs. Accordingly, the aims of this study were 1) to develop a methodology for generating TWA component models for use in BVR, and 2) to evaluate the accuracy of model-image registration in a single cadaveric model. A model of the carpal component was constructed from a CT scan, and a model of the radial component was generated from a surface scanner. BVR was acquired for three anatomical tasks from a cadaver specimen. Optical motion capture was used as the gold standard. BVR's bias in flexion/extension, radial/ulnar deviation, and pronosupination was less than 0.3°, 0.5°, and 0.6°. Translation bias was less than 0.2 mm with a standard deviation of less than 0.4 mm. This BVR technique achieved a kinematic accuracy comparable to previous studies on other total joint replacements. BVR's application to the study of TWA function in patients could advance the understanding of TWA and thus the implant's success.
Collapse
Affiliation(s)
- Bardiya Akhbari
- Department of Biomedical Engineering, Brown University, Providence, RI 02912
| | - Amy Morton
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912
| | - Douglas Moore
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912
| | - Arnold-Peter C Weiss
- Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912
| | - Scott W Wolfe
- Hand and Upper Extremity Center, Hospital for Special Surgery, New York, NY 10021
| | - Joseph Crisco
- Department of Biomedical Engineering, Brown University, Providence, RI 02912; Department of Orthopedics, Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI 02912
| |
Collapse
|
50
|
Horsager K, Madsen F, Odgaard A, Fink Jepsen C, Rømer L, Kristensen PW, Kaptein BL, Søballe K, Stilling M. Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry. Acta Orthop 2019; 90:67-73. [PMID: 30526183 PMCID: PMC6366473 DOI: 10.1080/17453674.2018.1543757] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods - 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results - The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02-0.07) for the cemented group and 0.05 mm/year (CI 0.02-0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI -0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1-5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation - The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang.
Collapse
Affiliation(s)
- Kristian Horsager
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| | - Frank Madsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Anders Odgaard
- Department of Orthopaedics, Herlev-Gentofte Hospital, Copenhagen University Hospital, Hellerup, Denmark
| | - Claus Fink Jepsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | | | - Bart L Kaptein
- Department of Orthopedic Surgery, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, Netherlands
| | - Kjeld Søballe
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| | - Maiken Stilling
- Department of Clinical Institute, Aarhus University, Aarhus, Denmark
| |
Collapse
|