1
|
Ren H, Zhang X, Li Z, Liu Z, Li J. Silica‐supported polymeric monolithic column with a mixed mode of hydrophilic and strong cation‐exchange interactions for microcolumn liquid chromatography. J Sep Sci 2016; 40:826-833. [DOI: 10.1002/jssc.201601035] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 10/30/2016] [Accepted: 11/21/2016] [Indexed: 12/12/2022]
Affiliation(s)
- Hang Ren
- Department of Chemistry Liaoning Normal University Dalian China
| | - Xinyue Zhang
- Department of Chemistry Liaoning Normal University Dalian China
| | - Zhen Li
- Department of Chemistry Liaoning Normal University Dalian China
| | - Zhaobin Liu
- Department of Chemistry Liaoning Normal University Dalian China
| | - Jinxiang Li
- Department of Chemistry Liaoning Normal University Dalian China
| |
Collapse
|
2
|
He J, Wang X, Morill M, Shamsi SA. Amino acid bound surfactants: a new synthetic family of polymeric monoliths opening up possibilities for chiral separations in capillary electrochromatography. Anal Chem 2012; 84:5236-42. [PMID: 22607448 DOI: 10.1021/ac300944z] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
By combining a novel chiral amino-acid surfactant containing an acryloyl amide tail, a carbamate linker, and a leucine headgroup of different chain lengths with a conventional cross-linker and a polymerization technique, a new "one-pot" synthesis for the generation of amino-acid based polymeric monolith is realized. The method promises to open up the discovery of an amino-acid based polymeric monolith for chiral separations in capillary electrochromatography (CEC). The possibility of enhanced chemoselectivity for simultaneous separation of ephedrine and pseudoephedrine containing multiple chiral centers and the potential use of this amino-acid surfactant bound column for CEC and CEC coupled to mass spectrometric detection are demonstrated.
Collapse
Affiliation(s)
- Jun He
- Center of Diagnostics and Therapeutics, Georgia State University, 50 Decatur Street, Atlanta, Georgia 30303, USA
| | | | | | | |
Collapse
|
3
|
Novel highly hydrophilic methacrylate-based monolithic column with mixed-mode of hydrophilic and strong cation-exchange interactions for pressurized capillary electrochromatography. J Chromatogr A 2011; 1218:4671-7. [DOI: 10.1016/j.chroma.2011.05.052] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2011] [Revised: 04/28/2011] [Accepted: 05/14/2011] [Indexed: 11/23/2022]
|
4
|
|
5
|
Kai Z, Zhi-Chao Z, Qin-Sun W, Ru-Yu G, Chao Y, Chuan-Yi Y, Zheng-Jin J. Separation of Basic Drugs Using Pressurized Capillary Electrochromatography. CHINESE J CHEM 2010. [DOI: 10.1002/cjoc.20030210414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
6
|
Abstract
Although there are many publications related to technological or methodological developments of CEC, few focus on the analysis of natural products, especially phytochemical bioactive compounds. This review summarized the application of CEC in the analysis of phytochemical bioactive components, including flavonoids, nucleosides, steroids, lignans, quinones and coumarins, as well as fingerprint analysis of herbs. The strategies for optimization of CEC conditions and detection were also discussed.
Collapse
Affiliation(s)
- Feng-qing Yang
- Department of Pharmaceutics, College of Chemistry and Chemical Engineering, Chongqing University, Chongqing, P. R. China
| | | | | |
Collapse
|
7
|
Jemere AB, Martinez D, Finot M, Harrison DJ. Capillary electrochromatography with packed bead beds in microfluidic devices. Electrophoresis 2009; 30:4237-44. [DOI: 10.1002/elps.200900334] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Abstract
Capillary electrochromatography (CEC) is a micro-separation technique that combines the advantages of capillary zone electrophoresis with those of high-performance liquid chromatography. Accordingly, it has attracted extensive attention over the last decade. Among the stationary phases for CEC, monolithic stationary phase has been regarded as the most suitable stationary phase for CEC because of its simple preparation, the elimination of frits, and its excellent performance. In this chapter, procedures for preparing CEC monolithic columns with an improved configuration, in which there are stationary phases at both sides of detection window and no stationary phase at detection window, are presented. The separation of acidic and basic compounds on such monolithic columns is used as an example to demonstrate CEC separation protocol. Additionally, an on-line concentration technique in CEC is presented. As a result of the coexistence of stationary phase and electric field in a CEC column, it is possible to employ chromatographic zone sharpening and field-amplified sample stacking effects simultaneously to improve CEC detection sensitivity.
Collapse
|
9
|
Dong J, Ou J, Dong X, Wu R, Ye M, Zou H. Preparation and evaluation of rigid porous polyacrylamide-based strong cation-exchange monolithic columns for capillary electrochromatography. J Sep Sci 2008; 30:2986-92. [PMID: 17924588 DOI: 10.1002/jssc.200700402] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A CEC monolithic column with strong cation-exchange (SCX) stationary phase based on hydrophilic monomers was prepared by in situ polymerization of acrylamide, methylenebisacrylamide, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a complete organic binary porogenic solvent consisting of DMSO and dodecanol. The sulfonic groups provided by the monomer AMPS on the surface of the stationary phase generate an EOF from anode to cathode, and serve as an SCX stationary phase at the same time. The monolithic stationary phase exhibited normal-phase chromatographic behavior for neutral analytes. For charged analytes, electrostatic interaction/repulsion with the monolith was observed. The strong SCX monolithic column has been successfully employed in the electrochromatographic separation of basic drugs, peptides, and alkaloids extracted from natural products.
Collapse
Affiliation(s)
- Jing Dong
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, China
| | | | | | | | | | | |
Collapse
|
10
|
Lin J, Wu X, Lin X, Xie Z. Preparation of polymethacrylate monolithic stationary phases having bonded octadecyl ligands and sulfonate groups: electrochromatographic characterization and application to the separation of polar solutes for pressurized capillary electrochromatography. J Chromatogr A 2007; 1169:220-7. [PMID: 17875313 DOI: 10.1016/j.chroma.2007.08.061] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2007] [Revised: 08/26/2007] [Accepted: 08/30/2007] [Indexed: 10/22/2022]
Abstract
In this report, the preparation of porous polymethacrylate-based monolithic columns by in situ copolymerization of octadecyl methacrylate (OMA), 3-sulfopropyl methacrylate (SPMA) and ethylene dimethacrylate (EDMA) in a binary porogenic solvent consisting of cyclohexanol/1,4-butanediol are proposed. These monoliths possess in their structures bonded octadecyl ligands and sulfonate groups and are evaluated in pressurized capillary electrochromatography (pCEC) system using small neutral and charged solutes. While the sulfonate groups are meant to generate the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary; the octadecyl ligands are introduced to provide the nonpolar sites for chromatographic retention for neutral solutes. However, incorporating the sulfonate groups in the monoliths does not only support the EOF but also exhibit hydrophilic interaction as well as electrostatic interaction/repulsion with the monoliths in addition to electrophoretic migration with polar charged solutes (e.g., nucleotides). The monolithic stationary phases at different EOF velocities are easily prepared by altering the amount of SPMA in the polymerization solution as well as the composition of the porogenic solvent. Optimum EOF velocity, the highest efficiency and adequate chromatographic retention are obtained when 0.6% SPMA is added to the reaction mixture. Under these conditions, rapid separation and high plate counts reaching greater than 170,000 plates/m are readily obtained.
Collapse
Affiliation(s)
- Jian Lin
- Department of Chemistry, Fuzhou University, Fuzhou 350002, China
| | | | | | | |
Collapse
|
11
|
Mistry K, Grinberg N. Separation of Peptides and Proteins by Capillary Electrochromatography. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120030601] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Kavita Mistry
- a Analytical Research , Merck & Co., Inc. , RY818‐C208, P.O. Box 2000, Rahway , New Jersey , 07065 , USA
| | - Nelu Grinberg
- a Analytical Research , Merck & Co., Inc. , RY818‐C208, P.O. Box 2000, Rahway , New Jersey , 07065 , USA
| |
Collapse
|
12
|
Al-Rimawi F, Pyell U. Investigation of the ion-exchange properties of methacrylate-based mixed-mode monolithic stationary phases employed as stationary phases in capillary electrochromatography. J Chromatogr A 2007; 1160:326-35. [PMID: 17543314 DOI: 10.1016/j.chroma.2007.05.035] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Revised: 04/30/2007] [Accepted: 05/10/2007] [Indexed: 10/23/2022]
Abstract
The potential of methacrylate-based mixed-mode monolithic stationary phases bearing sulfonic acid groups for the separation of positively charged analytes (alkylanilines, amino acids, and peptides) by capillary electrochromatography (CEC) is investigated. The retention mechanism of protonated alkylanilines as positively charged model solutes on these negatively charged mixed-mode stationary phases is investigated by studying the influence of mobile phase and stationary phase parameters on the corrected retention factor which was calculated by taking the electrophoretic mobility of the solutes into consideration. It is shown that both solvophobic and ion-exchange interactions contribute to the retention of these analytes. The dependence of the corrected retention factor on (1) the concentration of the counter ion ammonium and (2) the number of methylene groups in the alkyl chain of the model analytes investigated shows clearly that a one-site model (solvophobic and ion-exchange interactions take place simultaneously at a single type of site) has to be taken to describe the retention behaviour observed. Comparison of the CEC separation of these charged analytes with electrophoretic mobilities determined by open-tubular capillary electrophoresis shows that mainly chromatographic interactions (solvophobic and ion-exchange interactions) are responsible for the selectivity observed in CEC, while the electrophoretic migration of these analytes plays only a minor role.
Collapse
Affiliation(s)
- Fuad Al-Rimawi
- University of Marburg, Department of Chemistry, Hans-Meerwein-Strasse, D-35032 Marburg, Germany
| | | |
Collapse
|
13
|
Abstract
This review summarizes applications of CEC for the analysis of proteins and peptides. This "hybrid" technique is useful for the analysis of a broad spectrum of proteins and peptides and is a complementary approach to liquid chromatographic and capillary electrophoretic analysis. All modes of CEC are described--granular packed columns, monolithic stationary phases as well as open-tubular CEC. Attention is also paid to pressurized CEC and the chip-based platform.
Collapse
Affiliation(s)
- Ivan Miksík
- Institute of Physiology, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
| | | |
Collapse
|
14
|
Freitag R, Hilbrig F. Theory and practical understanding of the migration behavior of proteins and peptides in CE and related techniques. Electrophoresis 2007; 28:2125-44. [PMID: 17557365 DOI: 10.1002/elps.200600792] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
CEC is defined as an analytical method, where the analytes are separated on a chromatographic column in the presence of an applied voltage. The separation of charged analytes in CEC is complex, since chromatographic interaction, electroosmosis and electrophoresis contribute to the experimentally observed behavior. The putative contribution of effects such as surface electrodiffusion has been suggested. A sound theoretical treatment incorporating all effects is currently not available. The question of whether the different effects contribute in an independent or an interdependent manner is still under discussion. In this contribution, the state-of-the-art in the theoretical description of the individual contributions as well as models for the retention behavior and in particular possible dimensionless 'retention factors' is discussed, together with the experimental database for the separation of charged analytes, in particular proteins and peptides, by CEC and related techniques.
Collapse
Affiliation(s)
- Ruth Freitag
- Process Biotechnology, University of Bayreuth, Bayreuth, Germany.
| | | |
Collapse
|
15
|
Norton D, Rizvi SAA, Shamsi SA. Capillary electrochromatography-mass spectrometry of cationic surfactants. Electrophoresis 2006; 27:4273-87. [PMID: 17075924 DOI: 10.1002/elps.200600301] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The CEC-MS of alkyltrimethylammonium (ATMA+) ions with chain lengths ranging from C1-C18 is optimized using an internally tapered column packed with mixed mode reversed phase/strong cation exchange stationary phase. A systematic study of the CEC separation parameters is conducted followed by evaluation of the ESI-MS sheath liquid and spray chamber settings. First, the optimization of CEC separation parameters are performed including the ACN concentration, triethylamine (TEA) content, buffer pH and ammonium acetate concentration. Using 90% v/v ACN with 0.04% v/v TEA as mobile phase, the separation of longer chain C6-C18-TMA+ surfactants could be achieved in 15 min. Lowering the ACN concentration to 70% v/v provided resolution of shorter chain C1, C2-TMA+ from C6-TMA+ although the total analysis time increased to 40 min. Furthermore, variation of both the ACN and TEA content as well as ionic strength has found to significantly influence the retention of longer chain surfactants as compared to shorter chains. The optimum CEC conditions are 70% v/v ACN, 0.04% v/v TEA, pH 3.0 and 15 mM ammonium acetate. Next, the optimization of the ESI-MS sheath liquid composition is conducted comparing methanol to isopropanol followed by the use of experimental design for analysis of spray chamber parameters. Overall, the developed CEC-ESI-MS method allows quantitative and sensitive monitoring of ATMA+ from < or =10 microg/mL down to 10 ng/mL. Utilizing the optimized CEC-ESI-MS protocol, the challenging analysis of commercial sample Arquad S-50 ATMA+ containing cis-trans unsaturated and saturated soyabean fatty acid derivatives is demonstrated.
Collapse
Affiliation(s)
- Dean Norton
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30302-4098, USA
| | | | | |
Collapse
|
16
|
Zhang K, Yan C, Zhang Z, Wang Q, Gao R. Mixed Mode of Hydrophilic and Ionic Interaction Pressurized Capillary Electrochromatography for Separation of Basic Compounds. J LIQ CHROMATOGR R T 2006. [DOI: 10.1081/jlc-120022397] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Kai Zhang
- a State Key Laboratory of Elemento‐Organic Chemistry , Nankai University , Tianjin , 300071 , P.R. China
| | - Chao Yan
- b Unimicro Technologies, Inc. , Pleasanton , California , USA
| | - Zhichao Zhang
- a State Key Laboratory of Elemento‐Organic Chemistry , Nankai University , Tianjin , 300071 , P.R. China
| | - Qinsun Wang
- a State Key Laboratory of Elemento‐Organic Chemistry , Nankai University , Tianjin , 300071 , P.R. China
| | - Ruyu Gao
- a State Key Laboratory of Elemento‐Organic Chemistry , Nankai University , Tianjin , 300071 , P.R. China
| |
Collapse
|
17
|
Tan GM, Shi QH, Sun Y. Oscillatory transverse electric field enhances mass transfer and protein capacity in ion-exchange electrochromatography. J Chromatogr A 2005; 1098:131-7. [PMID: 16314169 DOI: 10.1016/j.chroma.2005.08.089] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2005] [Revised: 08/17/2005] [Accepted: 08/23/2005] [Indexed: 11/18/2022]
Abstract
Ion-exchange electrochromatography with an oscillatory electric field perpendicular to mobile-phase flow driven by pressure (pIEEC) was developed with a column design of rectangle cross-section. The effect of electric field strength on the dynamic binding capacity (DBC) was examined by frontal analysis of bovine serum albumin (BSA) adsorption to the packed beds of DEAE Sepharose FF in Tris-glycine buffer (pH 8.2). It was shown that the DBC at 10% breakthrough (Q(10)) in the pIEEC increased linearly with increasing the electric field strength. For example, with a packed-bed height of 15mm and electric potential gradient of 38V/cm, Q(10) increased four times over that in normal ion-exchange chromatography. So, the transverse electric field has created significant electro-kinetic mass transports (electroosmosis and electrophoresis) that intensified exterior liquid-film and intraparticle mass transfers, leading to the increased protein binding capacity. Due to the increased capacity in the pIEEC, partial resolution of BSA and IgG under an overload condition was realized without any process optimization. The results have revealed that an electric potential gradient of 20V/cm was enough to greatly enhance the DBC in the pIEEC, and when necessary, high electric field strength can be realized with a low applied voltage because the side distance of the column is usually an order of magnitude smaller than its height. The use of low voltage to carry out electrochromatography is a significant advantage of the pIEEC over conventional electrochromatography with axial electric field.
Collapse
Affiliation(s)
- Guo-Min Tan
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China
| | | | | |
Collapse
|
18
|
Xie C, Hu J, Xiao H, Su X, Dong J, Tian R, He Z, Zou H. Preparation of monolithic silica column with strong cation-exchange stationary phase for capillary electrochromatography. J Sep Sci 2005; 28:751-6. [PMID: 15938183 DOI: 10.1002/jssc.200400101] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A monolithic silica based strong cation-exchange stationary phase was successfully prepared for capillary electrochromatography. The monolithic silica matrix from a sol-gel process was chemically modified by treatment with 3-mercaptopropyltrimethoxysilane followed by a chemical oxidation procedure to produce the desired function. The strong cation-exchange stationary phase was characterized by its substantial and stable electroosmotic flow (EOF), and it was observed that the EOF value of the prepared column remained almost unchanged at different buffer pH values and slowly decreased with increasing phosphate concentration in the mobile phase. The monolithic silica column with strong cation-exchange stationary phase has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). The column efficiencies for the tested beta-blockers varied from 210,000 to 340,000 plates/m. A peak compression effect was observed for atenolol with the mobile phase having a low phosphate concentration.
Collapse
Affiliation(s)
- Chuanhui Xie
- National Chromatographic R & A Center, Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian 116011, China
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Steiner F, Scherer B. Separation of small peptides by electrochromatography on silica-based reversed phases and hydrophobic anion exchange phases. Electrophoresis 2005; 26:1996-2004. [PMID: 15852351 DOI: 10.1002/elps.200410325] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Peptide separations are regarded as a promising application of capillary electrochromatography (CEC) and, at the same time, a suitable model to elucidate its mixed separation mechanism when charged analytes are involved. In this paper, studies on the separation of small peptides (2-4 amino acids) on a Spherisorb octadecyl silane (ODS) phase at acidic pH and on a strong anion exchange (SAX)/C18 mixed mode phase at weakly basic pH are reported. For the ODS phase a comparison of CEC, capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC) under identical buffer/eluent conditions is presented. The predicted retention factors for CEC under the assumption of simple superposition of HPLC retention and CZE migration matched the measured results for the peptides that had small retention factors in HPLC. For both types of stationary phases, a variation of the acetonitrile content in the mobile phase led to a wide range of retention factors, including negative values when co-electroosmotic migration was dominant. Though both the ODS and the SAX/C18 phase offer unique advantages, the SCX/C18 phase at pH 9 provides more flexibility to alter separation selectivity for the selected peptides.
Collapse
Affiliation(s)
- Frank Steiner
- Instrumental Analysis and Bioanalysis, Saarland University, D-66041 Saarbrücken, Germany.
| | | |
Collapse
|
20
|
Ohyama K, Fujimoto E, Wada M, Kishikawa N, Ohba Y, Akiyama S, Nakashima K, Kuroda N. Investigation of a novel mixed-mode stationary phase for capillary electrochromatography. Part III: Separation of nucleosides and nucleic acid bases on sulfonated naphthalimido-modified silyl silica gel. J Sep Sci 2005; 28:767-73. [PMID: 15938185 DOI: 10.1002/jssc.200500030] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Capillary electrochromatography (CEC) with a novel stationary phase, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP), proved useful for the separation of nucleosides and nucleic acid bases. The application scope of SNAIP, which is a relatively polar reversed-phase (RP)-type stationary phase, was successfully expanded to include the CEC separation of polar compounds although the combination of non-polar RP phase with highly aqueous mobile phase is often inadequate. Due to the permanently charged sulfonic acid groups and the naphthalimidopropyl moiety, the retention of charged and relatively polar nucleosides as well as bases on the SNAIP stationary phase was effected by electrostatic and hydrophobic interactions. This yielded a unique selectivity on SNAIP toward nucleosides and bases. The characteristic EOF on SNAIP, which was stronger at higher aqueous content in the mobile phase, proved suitable for the separation of polar compounds in reversed-phase mode with highly aqueous mobile phase. In addition, when a double stepwise gradient was employed to accelerate the latest peak (adenine), the elution time was shortened to less than half its original duration.
Collapse
Affiliation(s)
- Kaname Ohyama
- Graduate School of Biomedical Sciences, Course of Pharmaceutical Sciences, Nagasaki University, Nagasaki, Japan
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Buszewski B, Kowalska S, Krupczyńska K. New Generation of Chromatographic Packings and Columns for Determination of Biologically Active Compounds. Crit Rev Anal Chem 2005. [DOI: 10.1080/10408340500207367] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
22
|
Ohyama K, Fujimoto E, Wada M, Kishikawa N, Ohba Y, Akiyama S, Nakashima K, Kuroda N. Investigation of a novel mixed-mode stationary phase for capillary electrochromatography. Part III1): Separation of nucleosides and nucleic acid bases on sulfonated naphthalimido-modified silyl silica gel. J Sep Sci 2005. [DOI: 10.1002/jssc.200400030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
23
|
Abstract
This review surveys the accomplishments in the separation of peptides and proteins by capillary electrochromatography (CEC) over the last decade. A significant number of research articles have been published on this topic since the last review. Peptide and proteins separations have been carried out in all three formats of CEC, i.e., packed bed, continuous bed and open-tubular (OT) format. In addition to electrophoresis, different chromatographic modes have been successfully exploited with the most prevalent being reversed-phase mode followed by ion-exchange. Although many researchers continue to use model proteins and peptides primarily to evaluate the performance of novel stationary phases some researchers have also applied CEC to the analysis of real-life samples. The potential of CEC to yield complementary information and sometimes a superior separation with respect to established techniques, i.e., microbore HPLC and capillary electrophoresis has been demonstrated. Instrumental modifications in order to facilitate coupling of CEC to mass spectrometry have further upgraded the value of CEC for proteomic analysis. Capillaries are still the separation vehicle of choice for most researchers yet the microfluidic platform is gaining momentum, propelled particularly by its potential for multitasking, e.g., performing different chromatographic modes in series.
Collapse
Affiliation(s)
- Dirk Bandilla
- Department of Chemistry and Biochemistry, Concordia University, Montréal, Que, H4B 1R6 Canada
| | | |
Collapse
|
24
|
Szucs V, Freitag R. Comparison of a three-peptide separation by capillary electrochromatography, voltage-assisted liquid chromatography and nano-high-performance liquid chromatography. J Chromatogr A 2004; 1044:201-10. [PMID: 15354439 DOI: 10.1016/j.chroma.2004.05.103] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
A mixture of three peptides was separated by capillary electrochromatography (CEC), nano-HPLC and voltage-assisted LC. In the latter case the charged analytes migrate through a neutral stationary phase driven by electrophoresis while their interaction with the stationary phase provides the basis for a chromatographic separation. The stationary phases used were poly(glycidyl methacrylate-co-ethylene dimethacrylate)-based monoliths that could be used directly as neutral "C1"-type columns for voltage-assisted LC and nano-HPLC, while their application in CEC became possible after derivatization of the epoxy groups with ionogenic N-ethylbutylamine functions. The separation of the peptide mixture was possible in all three modes. Highest plate numbers and resolutions were obtained under voltage-assisted conditions. The elution order showed dependencies on the charge density but also on the hydrophobicity of the peptides and was different in the three investigated chromatographic modes. The effect of changes in the ionic strength and the organic solvent content of the mobile phase on the resolution and the migration behavior of the peptides was investigated and showed the expected behavior. Voltage-assisted LC is suggested as an alternative to CEC for the separation of charged analytes by electrochromatography.
Collapse
Affiliation(s)
- Veronika Szucs
- Laboratory for Chemical Biotechnology, Faculty of Basic Science, Swiss Federal Institute of Technology, Lausanne, Switzerland
| | | |
Collapse
|
25
|
Ohyama K, Shirasawa Y, Wada M, Kishikawa N, Ohba Y, Nakashima K, Kuroda N. Investigation of the novel mixed-mode stationary phase for capillary electrochromatography. J Chromatogr A 2004; 1042:189-95. [PMID: 15296405 DOI: 10.1016/j.chroma.2004.05.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A novel packing material, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP), was prepared for the use as a stationary phase of capillary electrochromatography (CEC). The sulfonic acid groups on SNAIP stationary phase contributed to the generation of electroosmotic flow (EOF) at low pH and served as a strong cation-exchanger. In CEC with SNAIP, a mixed-mode separation was predicted, comprising hydrophobic and electrostatic interactions as well as electrophoretic migration process. In order to understand the retention mechanism on SNAIP, effects of buffer pH, concentration, and mobile phase composition on EOF mobility and the retention factors of barbiturates and benzodiazepines were systematically investigated. Moreover, the retention behavior of barbiturates on SNAIP was investigated and compared with those on octadecyl silica (ODS), phenyl-bonded silica, and 3-(1,8-naphthalimido)propyl-modified silyl silica gel to confirm the presence of pi-pi interaction on its retention mechanism. It was observed that a column efficiency was more than 85,000 N/m for retained compounds and the relative standard deviations for the retention times of EOF marker, thiourea, and five barbiturates were below 2.5% (n = 4). Under an applied voltage of 20 kV and a mobile phase consisted of 5 mM phosphate (pH 3.8) and 40% methanol, the baseline separation of five barbiturates was achieved within 3 min.
Collapse
Affiliation(s)
- Kaname Ohyama
- Department of Analytical Chemistry, Graduate School of Biomedical Sciences, Course of Pharmaceutical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| | | | | | | | | | | | | |
Collapse
|
26
|
Abstract
Two synthetic routes have been introduced and evaluated for the preparation of hydrophilic silica-based monoliths possessing surface-bound cyano functions. In one synthetic scheme, the silica monolith was reacted in a single step with 3-cyanopropyldimethylchlorosilane to yield a cyano phase referred to as CN-monolith. In a second synthetic route, the silica monolith was first reacted with gamma-glycidoxypropyltrimethoxysilane (gamma-GPTS), followed by a reaction with 3-hydroxypropionitrile (3-HPN) to give a stationary phase denoted CN-OH-monolith. Although the gamma-GPTS was intended to play the role of a spacer arm to link the 3-HPN to the silica surface, this spacer arm became an integral part of the hydrophilic stationary phase. Thus, the CN-OH-monolith can be viewed as a double-layered stationary phase (i.e., stratified phase) with a hydroxy sub-layer and a cyano top layer. Due to its stronger hydrophilic character, the CN-OH-monolith yielded higher retention and better selectivity than the CN-monolith. The CN-OH-monolith was demonstrated in the normal-phase capillary electrochromatography (CEC) of various polar compounds including phenols and chloro-substituted phenols, nucleic acid bases, nucleosides, and nitrophenyl derivatives of mono- and oligosaccharides. The CN-OH-monolith yielded a relatively strong electroosmotic flow over a wide range of mobile phase composition, thus allowing rapid separation of the polar compounds studied.
Collapse
Affiliation(s)
- Darin Allen
- Department of Chemistry, College of Arts and Sciences, 454A Physical Sciences, Oklahoma State University, Stillwater, OK 74078-3071, USA
| | | |
Collapse
|
27
|
Chapter 14 Chromatography of amino acids and peptides. ACTA ACUST UNITED AC 2004. [DOI: 10.1016/s0301-4770(04)80027-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
28
|
Jiskra J, Claessens HA, Cramers CA. Stationary and mobile phases in capillary electrochromatography (CEC). J Sep Sci 2003. [DOI: 10.1002/jssc.200301305] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
29
|
Zhang K, Gao R, Jiang Z, Yao C, Zhang Z, Wang Q, Yan C. Pressurized capillary electrochromatography separation of peptides with strong cation exchange and hydrophilic interaction. J Sep Sci 2003. [DOI: 10.1002/jssc.200301590] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
30
|
Hoegger D, Freitag R. Investigation of mixed-mode monolithic stationary phases for the analysis of charged amino acids and peptides by capillary electrochromatography. J Chromatogr A 2003; 1004:195-208. [PMID: 12929974 DOI: 10.1016/s0021-9673(03)00563-6] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The potential of N,N-dimethylacrylamide-piperazine diacrylamide-based monolithic stationary phases bearing sulfonic acid groups for electroosmotic flow generation is investigated for the separation of positively charged amino acids and peptides. The capillary columns were used under electrochromatographic but also under purely chromatographic (nano-HPLC) conditions and the separations interpreted as the result of possible chromatographic and electrophoretic contributions. The stationary phases were found to be mechanically stable up to pressures of 190 bar and chemically stable towards a wide variety of organic and hydro-organic mobile phases. In order to investigate the retention mechanism, the salt concentration and the organic solvent content of the (hydro-)organic mobile phase were varied in a systematic manner, taking three aromatic amino acids (phenylalanine, tryptophan, histidine) as model analytes. The respective contributions of electrostatic and hydrophobic and/or hydrophilic interactions were further investigated by varying the charge density and the hydrophobicity of the standard stationary phase. The former was done by varying the amount of charged monomer (vinylsulfonic acid) added during synthesis, the latter by (partially) replacing the interactive monomer (N,N-dimethylacrylamide) by other more hydrophobic monomers. A mixed mode retention mechanism based primarily on electrostatic interactions modified in addition by "hydrophilic" ones seems most suited to interpret the behavior of the amino acids, which stands in contradistinction to the previously investigated case of the behavior of neutral analytes on similar stationary phases. Finally the separation of small peptides was investigated. While the separation of Gly-Phe and Gly-Val was not possible, the separation of Phe-Gly-Phe-Gly and Gly-Phe but also of the closely related Gly-His and Gly-Gly-His could be achieved.
Collapse
Affiliation(s)
- Daniela Hoegger
- Center of Biotechnology, Swiss Federal Institute of Technology Lausanne, 1015 Lausanne, Switzerland
| | | |
Collapse
|
31
|
Fu H, Jin W, Xiao H, Huang H, Zou H. Peptide separation in hydrophilic interaction capillary electrochromatography. Electrophoresis 2003; 24:2084-2091. [PMID: 12858379 DOI: 10.1002/elps.200305462] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Separation of small peptides by hydrophilic interaction capillary electrochromatography (HI-CEC) has been investigated. The negative surface charge of a hydrophilic, strong-cation-exchange stationary phase (PolySULFOETHYL A) provided a substantial cathodic electroosmotic flow (EOF). The influence of acetonitrile content, ionic strength, mobile phase pH as well as applied voltage on the migration of the peptides was studied. Possible retention mechanisms of the peptides in HI-CEC were discussed. It was found that hydrophilic interaction between the solutes and the stationary phase played a major role in this system, especially when mobile phases with high acetonitrile content were used. However, an ion-exchange mechanism and electrophoretic mobility also affect the migration of the peptides in HI-CEC. Elution order and selectivity was proved to be different in HI-CEC and capillary zone electrophoresis (CZE), thus revealing the potential of HI-CEC as a complementary technique to CZE for the separation of peptides. Efficiency and selectivity of HI-CEC for the separation of peptides were demonstrated by baseline separating nine peptides in 6 min.
Collapse
Affiliation(s)
- Hongjing Fu
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian, China
| | | | | | | | | |
Collapse
|
32
|
Zhang K, Jiang Z, Yao C, Zhang Z, Wang Q, Gao R, Yan C. Separation of peptides by pressurized capillary electrochromatography. J Chromatogr A 2003; 987:453-8. [PMID: 12613841 DOI: 10.1016/s0021-9673(02)02063-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresiscan be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated.
Collapse
Affiliation(s)
- Kai Zhang
- State Key Laboratory of Elemento-Organic Chemistry, Nankai University, 94 Weijin Road, Tianjin 300071, China
| | | | | | | | | | | | | |
Collapse
|
33
|
Fu H, Huang X, Jin W, Zou H. The separation of biomolecules using capillary electrochromatography. Curr Opin Biotechnol 2003; 14:96-100. [PMID: 12566008 DOI: 10.1016/s0958-1669(02)00006-x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The unique properties of capillary electrochromatography such as high performance, high selectivity, minimum consumption of both reagents and samples, and good compatibility with mass spectrometry make this technique an attractive one for the analysis of biomolecules including peptides, proteins, carbohydrates, nucleosides and nucleotides. Irreversible adsorption between the biomolecules and the charged packing surface leads to a lack of reproducibility and serious peak tailing, so various approaches have been taken to overcome this and to improve the technique for future challenges.
Collapse
Affiliation(s)
- Hongjing Fu
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116011, China
| | | | | | | |
Collapse
|
34
|
|
35
|
Bedair M, El Rassi Z. Capillary electrochromatography with monolithic stationary phases: 1. Preparation of sulfonated stearyl acrylate monoliths and their electrochromatographic characterization with neutral and charged solutes. Electrophoresis 2002; 23:2938-48. [PMID: 12207302 DOI: 10.1002/1522-2683(200209)23:17<2938::aid-elps2938>3.0.co;2-8] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A novel monolithic stationary phase having long alkyl chain ligands (C17) was introduced and evaluated in capillary electrochromatography (CEC) of small neutral and charged species. The monolithic stationary phase was prepared by the in situ copolymerization of pentaerythritol diacrylate monostearate (PEDAS) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent consisting of cyclohexanol/ethylene-glycol/water. While AMPS was meant to support the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary, the PEDAS was introduced to provide the nonpolar sites for chromatographic retention. Monolithic columns at various EOF velocities were readily prepared by conveniently adjusting the amount of AMPS in the polymerization solution as well as the composition of the porogenic solvent. The monolithic stationary phases thus obtained exhibited reversed-phase chromatography behavior toward neutral solutes and yielded a relatively strong EOF. For charged solutes (e.g., dansyl amino acids), nonpolar as well as electrostatic interaction/repulsion with the monoliths were observed in addition to electrophoretic migration. Therefore, for charged solutes, selectivity and migration can be readily manipulated by changing various parameters including the nature of the monolith and the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). Ultrafast separation on the time scale of seconds of 17 different charged and neutral pesticides and metabolites were performed using short capillary columns of 8.5 cm x 100 microm ID.
Collapse
Affiliation(s)
- Mohamed Bedair
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078-3071, USA
| | | |
Collapse
|
36
|
Svec F. Capillary electrochromatography: a rapidly emerging separation method. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2002; 76:1-47. [PMID: 12126266 DOI: 10.1007/3-540-45345-8_1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
This overview concerns the new chromatographic method--capillary electrochromatography (CEC)--that is recently receiving remarkable attention. The principles of this method based on a combination of electroosmotic flow and analyte-stationary phase interactions, CEC instrumentation, capillary column technology, separation conditions, and examples of a variety of applications are discussed in detail.
Collapse
Affiliation(s)
- Frantisek Svec
- Department of Chemistry, University of California, Berkeley 94720-1460, USA.
| |
Collapse
|
37
|
Chen X, Zou H, Ye M, Zhang Z. Separation of enantiomers by nanoliquid chromatography and capillary electrochromatography using a bonded cellulose trisphenylcarbamate stationary phase. Electrophoresis 2002; 23:1246-54. [PMID: 12007123 DOI: 10.1002/1522-2683(200205)23:9<1246::aid-elps1246>3.0.co;2-c] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82,300 and 38,800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of trans-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111,100 and 107,400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.
Collapse
Affiliation(s)
- Xiaoming Chen
- National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, P. R. China
| | | | | | | |
Collapse
|
38
|
Ye M, Zou H, Wu R, Fu H, Lei Z. Modeling and optimization for separation of ionic solutes in pressurized flow capillary electrochromatography. J Sep Sci 2002. [DOI: 10.1002/1615-9314(20020501)25:7<416::aid-jssc416>3.0.co;2-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
39
|
Ye M, Zou H, Liu Z, Wu R, Lei Z, Ni J. Study of competitive binding of enantiomers to protein by affinity capillary electrochromatography. J Pharm Biomed Anal 2002; 27:651-60. [PMID: 11755765 DOI: 10.1016/s0731-7085(01)00608-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Affinity capillary electrochromatography (CEC) with zonal elution method was used to probe the competitive interactions of enantiomers with protein. In this approach, a known concentration of a competing agent is continuously applied to a CEC column with bovine serum albumin (BSA) physically adsorbed on SAX packing while injections of a small amount of analyte are made. The binding sites of solutes on the BSA molecule were determined by the changes in the retention factors of the solutes resulted from the addition of competitive agent. By using D- or L-tryptophan as competitive agents and D-, L-tryptophan and benzoin enantiomers as injected analytes showed that BSA molecule has a primary site to strongly bind L-tryptophan, but D-tryptophan dose not bind at this site; D- and L-tryptophan share a weak binding site on the BSA molecule. Benzoin enantiomers do not share any binding sites with either D- or L-tryptophan. Non-chiral compounds of trichloroacetic acid and n-hexanoic acid were applied as the competitive agents to study the binding of warfarin enantiomers to BSA, it was observed that trichloroacetic acid and n-hexanoic acid had a same binding site for warfarin enantiomers binding to BSA molecule.
Collapse
Affiliation(s)
- Mingliang Ye
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian 116011, China
| | | | | | | | | | | |
Collapse
|
40
|
Abstract
A review is presented of the most important recent applications of capillary electrochromatography (CEC) for the analysis of acidic, basic, and neutral compounds, of biomolecules, environmental substances, natural products, pharmaceuticals, and chiral compounds. Packed-column CEC (packed-CEC), open-tubular (OT-CEC), as well as pressure-assisted CEC (pseudo-CEC) are hereby considered. Papers published between July 1999 and April 2001 were taken into account. Applications before July 1999 have been reviewed in Electrophoresis 1999, 20, 3027-3065.
Collapse
Affiliation(s)
- G Vanhoenacker
- Ghent University, Department of Organic Chemistry, Belgium
| | | | | | | |
Collapse
|
41
|
Abstract
The article gives a comprehensive review on the recent developments in the applications of high-performance capillary electromigration methods, including zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography, to analysis, preparation and physicochemical characterization of peptides. The article presents new approaches to the theoretical description and experimental verification of electromigration behavior of peptides, and covers the methodological aspects of capillary electroseparations of peptides, such as strategy and rules for the rational selection of separation mode and experimental conditions, sample treatment, suppression of peptide adsorption to the inner capillary wall, new developments in individual separation modes and new designs of detection systems. Several types of applications of capillary electromigration methods to peptide analysis are presented: conventional qualitative and quantitative analysis for determination of purity, determination in biomatrices, monitoring of physical and chemical changes and enzymatic conversions, amino acid and sequence analysis and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of capillary electromigration techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- V Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague.
| |
Collapse
|
42
|
Byrne CD, Smith NW, Dearie HS, Moffatt F, Wren SA, Evans KP. Influence of the unpacked section on the chromatographic performance of duplex strong anion-exchange columns in capillary electrochromatography. J Chromatogr A 2001; 927:169-77. [PMID: 11572386 DOI: 10.1016/s0021-9673(01)01061-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This work describes initial investigations of strong anion-exchange (SAX) packing materials for capillary electrochromatography (CEC). The use of SAX phases in CEC is theoretically appealing for the analysis of negatively charged species. The reversed direction of the electroosmotic flow (EOF) generated by SAX phases (in comparison to reversed phases and strong cation-exchange phases) means that negative species can migrate with the EOF, not against it, hence the analysis times, of such species should be decreased and efficiencies improved. Duplex CEC columns (the standard for instruments using UV detection) consist of a packed and an unpacked section. Using common reversed-phase packing materials the direction of the EOF in both sections is co-linear, however when normal fused-silica capillaries are packed with SAX material the direction of the EOF in the two sections oppose one another. It has been shown, using conventional duplex CEC columns and fully packed CEC-MS columns that the opposing direction of EOF causes a massive degradation in column performance. Consequentially, it is demonstrated that if the EOF in the open section of the duplex SAX column can be controlled via pH or capillary derivatisation then good, reproducible CEC can be performed on anionic species using SAX packed CEC columns.
Collapse
Affiliation(s)
- C D Byrne
- Zeneca/SmithKline Beecham Centre for Analytical Sciences, Department of Chemistry, Imperial College of Science, Technology and Medicine, London, UK
| | | | | | | | | | | |
Collapse
|
43
|
Scherer B, Steiner F. Application of hydrophobic anion-exchange phases in capillary electrochromatography. J Chromatogr A 2001; 924:197-209. [PMID: 11521866 DOI: 10.1016/s0021-9673(01)01017-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Capillary electrochromatography (CEC) requires stationary phases that enable appropriate electroosmotic propel under various conditions. Analyte retention can be controlled through hydrophobic or electrostatic interaction with the packing material. The development and characterization of new strong anion-exchange materials with additional hydrophobic moieties (SAX/C18 mixed-mode phases) is described. The synthesis was based on polymer encapsulation of porous silica. The phases were systematically characterized by means of elemental analyses, HPLC frontal analyses and CEC experiments. The studies focused on the influence of various parameters (e.g., pH, kind of buffer, capillary wall) on the electroosmotic flow (EOF). Phases with high anion-exchange capacity generated a fast and constant EOF over a wide pH range. Long-time stability of EOF and hydrophobic retention under CEC conditions were demonstrated within the course of 100 consecutive injections. The applicability of the SAX/C18 phases in appropriate buffer systems is demonstrated for neutral, acidic and basic compounds.
Collapse
Affiliation(s)
- B Scherer
- University of the Saarland, Instrumental/Environmental Analysis, Saarbrücken, Germany
| | | |
Collapse
|
44
|
Liu Y, Pietrzyk DJ. Capillary-electrochromatographic separations with copolymeric reversed-stationary phase and ion-exchanger-packed columns. J Chromatogr A 2001; 920:367-75. [PMID: 11453022 DOI: 10.1016/s0021-9673(01)00597-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A macroporous, spherical, 7 microm, polystyrene-divinylbenzene (PS-DVB), reversed-phase adsorbent (PRP-1) was evaluated as a stationary phase for the capillary electrochromatographic (CEC) separation of neutral, acidic, and basic analytes of pharmaceutical interest. Electroosmotic flow (EOF) for a PRP-1 packed capillary is nearly constant over the pH 2 to 10 range and is higher than for a silica-based C18 packed capillary on the acidic side. EOF increases with an increase in buffer acetonitrile concentration or as applied potential increases. As analyte hydrophobicity increases, analyte retention and migration time increases. Increasing buffer acetonitrile concentration reduces analyte partitioning with the PS-DVB stationary phase and analyte retention and migration time decreases. When exchange sites are present on the PS-DVB copolymer, EOF (EOF is reversed for the anion-exchanger) increases as the exchange capacity increases. An increased exchange capacity also reduces partitioning of the analyte with the PS-DVB matrix and analyte retention and migration time decrease. Because of excellent stability in an acid environment, the PRP-1 packed capillary can be used in strong acid buffer solution and weak acid and base analytes depending on pKa values can be separated as neutral species and cations, respectively. CEC separations on a PRP-1 capillary of neutral steroids, weak base pharmaceuticals (separation as cations), purines and pyrimidines (as cations), fatty acids (as undissociated species), and sulfa derivatives (as cations) are described. Efficiency for the PRP-1 packed capillary for acetone or thiourea as the analyte is about 6 x 10(4) plates m(-1).
Collapse
Affiliation(s)
- Y Liu
- University of Iowa, Department of Chemistry, Iowa City 52242, USA
| | | |
Collapse
|
45
|
Hilder EF, Zemann AJ, Macka M, Haddad PR. Anion-exchange capillary electrochromatography with indirect UV and direct contactless conductivity detection. Electrophoresis 2001; 22:1273-81. [PMID: 11379948 DOI: 10.1002/1522-2683(200105)22:7<1273::aid-elps1273>3.0.co;2-u] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Conductivity detection is applied to ion-exchange capillary electrochromatography (IE-CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex-agglomerate anion-exchanger (Dionex AS9-SC). A systematic approach was used to determine suitable eluants for IE-CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p-toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p-toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4-25 microg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5-50 mM p-toluenesulfonate) than was the case with indirect UV detection (2.5-10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p-toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion-exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).
Collapse
Affiliation(s)
- E F Hilder
- Australian Centre for Research on Separation Science, University of Tasmania, Hobart
| | | | | | | |
Collapse
|
46
|
Separation of acidic and neutral compounds by strong anion-exchange capillary electrochromatography dynamically modified with sodium dodecylsulfate. Chromatographia 2001. [DOI: 10.1007/bf02491079] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Ye M, Zou H, Lei Z, Wu R, Liu Z, Ni J. Enantiomer separation by strong anion-exchange capillary electrochromatography with dynamically modified sulfated beta-cyclodextrin. Electrophoresis 2001; 22:518-25. [PMID: 11258764 DOI: 10.1002/1522-2683(200102)22:3<518::aid-elps518>3.0.co;2-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A novel mode of capillary electrochromatography (CEC) based on a dynamically modified stationary phase was presented for chiral separation. The capillary column was packed with strong anion-exchange (SAX) stationary phase packing; the sulfated beta-cyclodextrin (S-CD), which was added to the mobile phase, was dynamically adsorbed to the packing surface. Separation of enantiomers was achieved by their different abilities to form an inclusion complex with the adsorbed S-CD. The enantiomers of tryptophan, praziquantel, atropine, metoprolol, and verapamil were successfully separated in this system with a column efficiency of 36000-412000 plates/m. The resolution value obtained for atropine was as high as 11.23. The superiority of CEC with a dynamically modified stationary phase over that with a physically adsorbed stationary phase was demonstrated. The influence of ionic strength, S-CD concentration, and methanol content on separation was also studied.
Collapse
Affiliation(s)
- M Ye
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, The Chinese Academy of Sciences
| | | | | | | | | | | |
Collapse
|
48
|
Gaspari M, Gu?ek M, Walhagen K, Vreeken RJ, Verheij ER, Tjaden UR, Van der Greef J. Ion trap mass spectrometry as detector for capillary electrochromatography of peptides: Possibilities and limitations. ACTA ACUST UNITED AC 2001. [DOI: 10.1002/mcs.1049] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
49
|
Colón LA, Maloney TD, Fermier AM. Packed Bed Columns. ACTA ACUST UNITED AC 2001. [DOI: 10.1016/s0301-4770(01)80076-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
|
50
|
Abstract
Capillary electrochromatography (CEC) continues to captivate many separation scientists. A remarkable activity is apparent from the numerous publications in the literature using CEC. A review of the most recent progress in CEC is presented herein, covering an extensive fraction of the literature on CEC published from the year 1997 until the beginning of 2000. Most of the recent developments have concentrated on column technology.
Collapse
Affiliation(s)
- L A Colón
- Department of Chemistry, State University of New York at Buffalo, 14260-3000, USA.
| | | | | | | | | |
Collapse
|